9 Commits
113 changed files with 221 additions and 24237 deletions

No files matched your search

+33 -43
View File
@@ -1,43 +1,33 @@
/bridges/captures/
# Capture artefacts that land beside the bridge scripts. Deliberately NOT
# `/bridges/s3-bridge/` -- proxy.py and s3_bridge.py live there and are tracked.
/bridges/*.bin
/bridges/s3-bridge/*.bin
/bridges/s3-bridge/*.log
/bridges/s3-bridge/*.set
/example-events/
/tests/fixtures/
/manuals/
# Python build artifacts
*.egg-info/
dist/
build/
# Python bytecode
__pycache__/
*.py[cod]
# Virtual environments
.venv/
venv/
env/
# Editor / OS
.vscode/
*.swp
.DS_Store
Thumbs.db
# Analyzer outputs
*.report
claude_export_*.md
# Frame database
*.db
*.db-wal
*.db-shm
# Config-block snapshots from scratch/mm_config_diff.py (device dumps, not source)
scratch/mm_config_snaps/
/bridges/captures/
/example-events/
/tests/fixtures/
/manuals/
# Python build artifacts
*.egg-info/
dist/
build/
# Python bytecode
__pycache__/
*.py[cod]
# Virtual environments
.venv/
venv/
env/
# Editor / OS
.vscode/
*.swp
.DS_Store
Thumbs.db
# Analyzer outputs
*.report
claude_export_*.md
# Frame database
*.db
*.db-wal
*.db-shm
-744
View File
@@ -4,750 +4,6 @@ All notable changes to seismo-relay are documented here.
---
## Unreleased
### Fixed
- **Waveform event times were the monitoring-session start, not the trigger
(~hours off).** `read_blastware_file` stamped events with footer `ts1`, which
for a waveform is the session start a unit shares across every event that day
(a unit arming at 06:00 stamped 06:00 on all of them — the modal and PDF both
showed it, since it's the stored value). The event time is footer `ts2` (the
recording stop), and Blastware's trigger = `ts2 - record time`. The record
time is a big-endian float32 in the recording-setup config block (30 bytes
before the `Standard Recording Setup` marker), so the **exact trigger is now
recovered from the binary alone** — all 7 BE12844 oracle events decode to
their exact Blastware time (e.g. N844LQHB 10:33:29), no paired `.TXT` needed.
Histograms keep `ts1` (the ~24 h window start). A paired report's
`event_datetime` stays authoritative (unit-clock drift).
⚠ **Needs a re-decode backfill** to correct existing stored events' timestamps.
- **`scratch/mm_frame_parse.py` accepted either checksum rule, so it could not
falsify either.** It tried plain SUM8 *and* a DLE-aware variant and reported
whichever matched, which is why it never flagged a bad frame and why the
protocol reference carried the wrong rule for two days — "zero bad checksums
across three sessions" was true and carried no information. It now validates
against SUM8 alone and names the DLE-aware result only as a near-miss, never as
a pass. Still zero bad frames across all captures, strictly tighter.
- **A 64 KB download cap, one event away from biting.** The `0x5A` chunk offset
was written as a **uint16** at `params[2:4]`, because every offset THOR was
observed to send fits in two bytes (largest `0x3400` = 13,312) — which capped a
download at 65,536 B. UM20147 holds a **72,560-byte** event, so that cap was
not hypothetical: the event could not have been fetched at all.
`params[0:4]` is demonstrably one 4-byte field (chunk 0 puts the 4-byte event
key there), so writing the offset as a uint32 BE is **byte-identical below
65,536** — the replay test still matches all 74 of THOR's frames — and reaches
past it. ✅ Confirmed on the unit: **71 chunks, exact size.**
⚠ **This is the Series III 64 KB page-boundary bug wearing a different hat**,
and that one is *still open* — `parse_strt_end_offset()` discards the key's page
byte and the `5A` walk crashes once a unit's buffer crosses 64 KB. The
transferable lesson: *an address field whose high bytes are zero in every
capture is not a narrow field, it is an untested one.* Same mistake, found
twice, in code written years apart.
- **The probe's own control was circular.** `scratch/mm_stream_probe.py` compared
each candidate request size against a reference download that used the library
*default* chunk size — which the same change had just raised to 16,384. A fault
at 16 KB would have been shared by the control and every comparison would have
passed. Pinned to `THOR_CHUNK_SIZE`, the only size with THOR's captures behind
it.
- **`mm_client_check.py` reported THOR's request count, not its own.** It printed
"71 chunks" for a download that made **5 requests**, computing `size / 1024`
while the download used the 16 KB default — nearly reading a working 16 KB
download as a broken 1 KB one. A diagnostic that misreports what it did is
worse than one that says nothing.
- **The ACH server buffered its own output and mislabelled modem chatter.**
stdout was block-buffered, so the log read **empty** while a call was in
progress — useless for a tool whose job is being watched during a one-shot
event. It also left `RADIO RING` as a hex dump; it now names known modem
strings and, on rings without a `CONNECT`, says what to check. And its
docstring promised scanners leave no trace on disk while the failure path
created a session directory regardless.
- **`.gitignore` missed capture artefacts beside the bridge scripts.** Targets
`*.bin`/`*.log`/`*.set` specifically — **not** `/bridges/s3-bridge/`, which
holds tracked source.
- **The Series-4 config watcher overwrote the previous session's snapshots.**
`scratch/mm_config_diff.py watch` saved every run as `watch-000…NNN`, so each
session silently replaced the last -- harmless while they were clock ticks,
data loss once they were findings. Labels are now `watch-MMDD-HHMM-NNN`.
- **`mm_client_check.py` carried two stale labels.** It still printed `0x06`
content[4:8] as "unexplained" (it is very likely the monitor-log count -- see
*Changed*) and announced UM20147 as "the FIRST 11.0BD unit this code has met".
### Added
- **Diagnostics tab in the SFM standalone webapp.** Surfaces the device
endpoints that previously existed only as `curl`: `events/storage_range` and
`events/index` alongside `monitor/status`, then stop monitoring, disable ACH
(`rescue?erase=false`, so stored events survive), and erase. The wedged-unit
ladder — slow drip and blind stop — sits under its own heading pointing at
`docs/runbooks/wedged_unit_recovery.md`, with the reminder that `slow_drip`'s
success signal is `bytes_received > 0` and not a clean duration. Erase is
guarded by typing the unit's serial: auth answers *who*, not *did you mean
it*, and Swagger's try-it-out button on `/device/events/erase` is live on
`:8200/docs`.
- **`docs/sfm_tool_status.md`** — an honest per-capability maturity assessment:
what is production-grade (the codec library, the data side), what is
emergency-grade (the device side), what is a research artifact, the
known-issues table, and the gap to a real tool. Also records the **5A
page-boundary bug** as known: `parse_strt_end_offset()` discards the key's
page byte, so once a unit has recorded more than 64 KB since its last erase,
an event spanning the boundary reads an `end_offset` *behind* its own start —
the chunk loop fetches nothing and TERM packs a negative `offset_word`, which
500s. Reproduced on BE12599. Production is unaffected: it ingests complete
files via the watcher path and never runs this walk.
- **The Micromate (Series IV) live wire protocol, reverse-engineered end to
end** — `docs/micromate_protocol_reference.md`. Worked out against a bench
UM12947 over USB and a recording relay, with THOR driving every write so that
no command has ever been originated against a unit by this project. **A
Micromate answers Series III command frames**, with three framing differences:
responses carry no leading `DLE`, `payload[1]` is `0xC5` (Blastware firmware)
or `0x03` (Thor firmware) rather than `0x10`, and the data length is a
**uint16 BE at `payload[8:10]`** — read as a single byte it under-reads
`SUB 0x1A` by 47x. Read path, event chain, and `SUB 0x5A` streaming the
`.IDFW` file verbatim are all confirmed.
- **Series IV setup management, fully mapped.** `0x41` reads the active setup
name, `0x1A` its config block, `0xDA` names the target `.MMB`, `0x71`/`0x72`
write it back. **Setups are read-modify-write** — the written block is the
read block, 91% byte-identical at a fixed 11-byte shift. `0xDA` **creates**
files rather than only overwriting, confirmed on the unit's own screen, and an
overwrite is protocol-identical to a create: no handshake, no warning, and no
protection even over the *active* setup of a monitoring unit.
- **The scheduler file decoded** — `\system\schedule\schedule.dat`, 260-byte
records carrying an action bitmask (2 start, 4 stop, 8 self-check, 16 ACH), a
half-hour slot (48/day), day-of-week (0 = Sunday) and a length-prefixed setup
name. Verified entry-for-entry against the operator's own THOR screen.
- **A generic file transfer addressed by full path** — `0x94`/`0x48` read,
`0x8D`/`0x8E` write. This **retracts** an earlier conclusion in the same
document that no such command existed; that was inferred from absent firmware
strings and was wrong.
- **Monitoring control and per-event delete.** `0x96`/`0x97` start and stop as
on Series III, but the monitoring flag at `SUB 0x1C` `data[12]` must be tested
for **non-zero** (observed as both `0x0E` and `0x0C`) rather than compared to a
constant. Deletion is **per-event** — `0xA8` with the event key, then `0xAA` —
which is safer than Series III's erase-everything. `SUB 0x1C` also carries the
device clock.
- **`bridges/mm_probe.py`** — distinguishes the four faults THOR reports
identically as "disconnected": refused, connect timeout (the silent-drop
signature of a trusted-IP whitelist), **connected but no reply** (the modem
answered and the unit did not), and replied. Each verdict names what to try
next. `--slots N` tests single-session modem behaviour.
- **`bridges/mm_link.py`** — a bench stand-in for a cellular modem, with a
decoded timestamped log and fault injection (`blackhole`, `drop`, `delay`,
`onewaydev`) driven by a control file. No pyserial; stdlib `termios` only.
- **`scratch/mm_frame_parse.py`**, **`socat_log_split.py`** and **`fake_unit.py`**
— a Micromate-aware frame parser (`S3FrameParser` cannot see these responses at
all, since it scans for `DLE+STX`), byte-exact capture recovery from a
`socat -x` relay log, and a serial-port stand-in that answers as a unit.
- **A live client for Series IV — `micromate/{framing,protocol,client}.py`.**
`micromate/` was codec-only; it can now talk to a unit. Connect over TCP (a
cellular modem) or serial/USB, identify a unit, read its state, clock, battery,
memory and setups, walk the event chain and download events as `.IDFW`/`.IDFH`
bytes the existing codec already decodes. **98 offline tests**, every response
constant a real captured data section. `minimateplus/transport.py` is reused
as-is; `minimateplus/framing.py` deliberately is **not** — see *Changed*.
⚠ **Read-only.** Setups, schedules, call-home config, monitoring start/stop
and per-event delete are all mapped and none are implemented. No command has
ever been originated against a unit by this project; every write in the
protocol reference was performed by THOR while we recorded.
- **Verified on real hardware, both transports, both firmware lines.** Identical
wire bytes over USB CDC-ACM and an RX55 in PAD mode — 11,580 B in and 761 B out
to the byte. Every `11.0BD` inference confirmed on UM20147, including the four
extra trailing bytes in `SUB 0x1C` that make Series III's from-the-end offsets
report a battery voltage of **577.92 V**. A monitoring unit answers reads with
no `SESSION_RESET`, which Series III requires. All six bench events decode
with the existing IDF codec — 4 waveforms at 12,288/12,288/12,288/8,192 samples
and 2 histograms — so `/db/import/idf_file` ingests a directly downloaded event
unchanged.
- **`bridges/mm_client_check.py`** — drives the read client against a unit and
reports per-command timings, read counts and byte totals, so two transports or
two firmware lines can be diffed. `--capture DIR` writes a `raw_bw_*`/`raw_s3_*`
pair in the layout `scratch/mm_frame_parse.py` reads, turning a field run into
a test fixture. No pyserial — stdlib `termios`, because `pip install` is
refused outright by PEP 668 on the distros the bench hosts run.
- **The Series-4 event chain.** `MicromateEventRef` plus `list_events()`,
`iter_events()`, `download_event()`, `get_event()` and `decode_error()` on
`MicromateClient`. Walk a unit's events with full metadata — key, size, type,
timestamp, sensor location, setup name, per-channel peaks, peak vector sum —
then download and decode any of them, waveform or histogram.
`ref.filename` generates the name THOR would have used
(`UM12947_20260923163319.IDFW`), returning None rather than guessing when the
record type is unknown, because `read_idf_file()` dispatches on exactly that
suffix.
The load-bearing test replays THOR's captured six-event session and asserts
**every byte we emit matches its 74 frames**, decoding all six events along the
way. Read-only, like the layers under it.
- **A per-event decode self-check.** `get_event(verify=True)` recomputes the peak
vector sum from the decoded samples and compares it against the float the
*device* put in the `0x0C` record — two independent computations over the same
samples, so a disagreement means our decode is wrong. Agreement on the bench
events is **0.000%**. Worth having in a codebase whose decode failures have
historically been silent: unhandled block tags shorten a channel and nothing
raises. ⚠ It is a decode-correctness check, **not** a truncation detector — a
channel cut after its peak still yields the right PVS.
- **`SUB 0x06` content[0:4] is the event count.** Three for three across both
firmware lines (0 events→0, 6→6, 5→5), and THOR reads it *before* the chain walk
then stops without ever reading the sentinel. `list_events()` still walks to
the sentinel — correct on evidence, one round trip slower — but this lets a
caller ask "is there anything here?" in one command. `content[4:8]` reads **9**
on both units regardless of count, so it is a constant, not a count.
- **`bridges/mm_ach_server.py` — an inbound Auto Call Home receiver.** Read-only,
and deliberately more so than its Series III sibling, which has rescue actions
that stop monitoring and disable ACH. Its grace window is the experiment: it
stays **silent** after accepting, to answer the one question no packet capture
can — does the unit speak first? Captures land as `raw_bw_*`/`raw_s3_*` so
`scratch/mm_frame_parse.py` reads the pair unchanged.
⚠ Implements the **listener** path only. See *Changed* — there are two.
- **🔑 `MicromateClient.get_setup()` -- a Micromate's setup, decoded.** One `SUB
0x1A` read returns a `MicromateSetup`: record mode, sample rate, histogram
interval, pre-trigger, stop mode, record time, auto-stop, active sensors,
trigger sources, the three geophone trigger levels, mic type and (linear) mic
trigger, job number, scaled distance, and the four notes. **Measured fields
only** -- anything the reference grades inferred stays in `.raw`. A failed
checksum raises `SetupChecksumError` (a `ProtocolError`) unless `verify=False`;
a short block raises either way. The decode lives in the new pure module
`micromate/setup_block.py`.
**Verified on hardware:** against UM20147, every decoded value matched the
unit's own screen. 69 tests on 15 real reads (14 UM20147, one UM12947 cut from
Thor's 9-24 capture), with expected values taken from the operator's screen,
never from the decoder.
- **One checksum rule for three config blocks** -- `micromate.setup_block.crc_ok()`.
`content[0:2]` is a length N; a CRC-16/AUG-CCITT over `[0:N-2]` is stored at
`[N:N+2]`. Holds for `0x1A` (setup, 48 distinct states), `0x08` (preferences)
and `0x2E`; `0x2C` has none. Thor's `0x71` write omits it -- the unit computes
it -- so it is a read-side integrity check, not a write obligation.
- **`scratch/mm_config_diff.py`** -- the config diff harness (`volatile` / `snap`
/ `watch` / `diff`), read-only. An operator changes one setting on the unit's
own keypad while `watch` reports which bytes moved; this is how the map below
was built. Checks the CRC on every change to a checksummed block.
- **`bridges/mm_client_check.py` prints the decoded setup**, laid out to be
checked line by line against the unit's screen.
### Changed
- **Connecting to a unit no longer walks its event chain.** `/device/events`
reads every event header over the cellular link; on a unit with a large or
wrapped chain that takes minutes or fails outright, and it fired
automatically on every connect. Connect now uses only ~2 s probes —
`/device/info` (which already carried the compliance config the walk was
re-reading) plus `events/storage_range` — and the Device tab gains an Event
Chain card. The walk moved behind a **Load events** button in the Events
toolbar. Knowing whether a unit's ACH is on no longer requires reading every
event it has stored.
- **Recorded what THOR actually does on the wire**, measured rather than assumed.
A "status check" is **eleven commands, ~2.2 KB including TCP setup** — 18.8
MB/day per unit at a 10 s cadence, against ~0.2 MB/day for a `POLL` +
`MONITOR_STATUS` check at 60 s. The **status interval is honoured; the
connection interval is not** — it sets `(status / connection) - 1` checks per
cycle, so equal values yield *zero* cheap checks and every connection becomes
the expensive one.
- **Two THOR defects reproduced with timestamps.** After a connection drops
mid-download it retries **once**, stops polling entirely and **never resumes**,
while displaying `Connected` for as long as it is left alone — and `Idle` for a
unit that is actively recording. Separately, THOR's own log shows a
**subscription leak**: one logical event dispatched to a growing number of
handlers, **1 to 12 over ten hours** of uptime, consistent with the field
report that only a restart recovers it.
- **The Micromate's USB host supports FTDI and CDC-ACM only** — no Prolific, in
either firmware line. A PL2303 cable (Benfei) leaves a unit with no working
modem port; an FTDI cable (Sabrent) works. Both are in circulation and
indistinguishable by eye — identify by `lsusb` VID, `0403` against `067b`.
- **Six rules in the Series-4 client spec were wrong, and measuring against the
captures caught all six before any code shipped.** Each fails *silently* —
a frame the unit ignores, or a checksum that reads as bad:
requests escape **four** byte values (`0x02 0x03 0x04 0x10`), not one, so the
Series III builder reproduces only **161 of THOR's 218** read frames and misses
*every* `SUB 0x5A` download; the response checksum is **plain SUM8** of the
de-stuffed payload, not the DLE-aware variant, which disagrees with the wire on
**55 of 251** frames; `SUB 0x5A` is a **1024-byte chunk loop**, not one request
per event; `SUB 0x0A` is the **monitor-log walk** (same request repeated,
device-side cursor), not a keyed event-header read; `1E`/`1F` carry **token
`0xFE`** at `params[7]`; and `SUB 0x01` has **no THOR precedent at all**.
Recorded in `docs/micromate_protocol_reference.md` as corrections in place.
- **`SUB 0x0C`'s peak float is the per-sample peak vector sum** — resolved after
being marked *do-not-rely-on*. Exact to **0.000%** on all four bench waveforms
against a PVS recomputed from decoded samples, so its offset (`Tran` label − 12)
is established rather than inferred. The earlier "not the vector sum" reading
compared against `sqrt(Σpeak²)` from the three *reported* peaks, which is an
upper bound: the channel maxima do not occur at the same instant. **This gives
the decoder a free self-check** — the device computed that number from the same
samples, independently of our codec, so a mismatch means the decode is wrong.
Worth having in a codebase whose channel truncations have historically been
silent.
- **Cellular costs ~0.65 s per round trip, independent of payload size.**
Measured on UM12947 over an RX55: `list_setups()` on a unit with 24 setups takes
**16.0 s**, against 0.46 s over USB, for 24 commands. A 1,024-byte chunk and a
16-byte state read cost the same. **Over cellular, minimise round trips, not
bytes** — cache the setup list rather than refreshing it on a timer, and note a
13 KB event is 14 chunks ≈ 8.4 s of latency against ~0.03 s of data. The modem
also needs **fewer** reads than USB, not more: it buffers ~1 s then forwards one
large segment where CDC-ACM delivers many small ones.
- **Event keys collide across units.** UM20147's first event and UM12947's first
event are both `055d4a81` — different sizes, different contents, identical key.
The counter starts from the same value on every unit, so **a key is meaningless
without its serial**. Anything that stores, deduplicates or addresses Series IV
events must key on `(serial, event_key)`; keyed on the event key alone, one
unit's event is silently treated as a duplicate of another's and simply never
ingested. Series III has the cousin of this — its counter resets after an
erase, so keys are reused *within* a unit, which is why `ach_state.json` already
tracks `max_downloaded_key` per serial.
- **Setup file names are spelled three ways by three commands.** In one session
on one unit: `0x41` reported `test2.MMB`, `0x40` reported `test2.mmb`, and `0x0C`
reported `test2`. **Compare setup names case-insensitively and without the
extension** — an exact-string test of "is the active setup one I know about?"
answers *no*.
- **16,384 bytes per `0x5A` request, up from THOR's 1024.** Measured on UM20147
with every size checked byte-for-byte against a 1024 B control: 1 K / 2 K / 4 K
/ 8 K / 16 K all served in full, and anything larger is **silently clamped to
16,384** — correct bytes, short length, no error.
⚠ **That clamp is why the download loop now tracks its offset by bytes
received** rather than striding by chunk index. A fixed stride would either
fail on a clamp or skip the bytes it never collected; tracking what arrived
makes a clamp cost one extra request and makes the loop self-correcting against
any short response. Consequence worth stating because it reverses an earlier
decision: **a short chunk is no longer an error.** The device returns short
legitimately; the protection is the offset arithmetic plus the final
total-length check, which still raises on a genuinely truncated event.
`THOR_CHUNK_SIZE = 1024` remains available and the replay tests pin it.
Confirmed over a cellular PAD as well as USB: 14,176 B in one frame, intact.
- **⚠ Corrected: cellular cost is NOT independent of payload.** This changelog
and the protocol reference both previously said **"~0.65 s per round trip,
regardless of payload"**, and the design advice drawn from it — *minimise round
trips, not bytes* — was too strong. Every measurement behind that claim had a
payload under 1 KB (59 B status, 266 B setup records, 1024 B chunks), so the
byte term was small and similar across all of them and per-command cost looked
constant. It was a narrow-range fit extrapolated past its evidence.
Measured against a 14,176 B single response over an RX55:
**`t ≈ 0.21 s + bytes / 2,350`**, fitting within ±11% across a 14× size range.
The old figure is that model evaluated at 1 KB.
**The advice splits in two:** *status* work is round-trip bound (a 24-setup walk
really is 16 s, so cache it), while a *download* is **throughput bound** — the
16 KB chunk size saves ~30% on a large event, **not 14×**, because most of the
time is bytes on the wire and batching does not touch it. A 72,560-byte event
is ~46 s at 1024 B and ~32 s at 16,384 B.
- **⚠ Retracted: there is no `SUB 0x5A` streaming mode.** The reference
hypothesised that `offset_hi = 0x10` meant "stream until done", reconciling
THOR's chunk loop with a 2026-09-23 note about a single request returning an
entire 11 KB event. Measured directly: **`offset` is simply a byte count** and
the device returns exactly `offset + 11` bytes in one frame. `0x1000` is not a
marker, it is part of the number. The probe tried **both escapings** of
`offset_hi`, which is what makes the negative meaningful — a malformed frame
would have produced the same silence, and Series III requires that byte raw in
this very command.
- **Verified on real hardware across both firmware lines and both transports.**
Identical wire bytes over USB CDC-ACM and an RX55; every `11.0BD` inference
confirmed on UM20147 — including the four extra trailing bytes in `SUB 0x1C`
that make Series III's from-the-end offsets report **577.92 V**; a monitoring
unit answers reads with no `SESSION_RESET`; and `0x0C` content[11] gives the
record type (`0x07` waveform / `0x08` histogram) on 7 events across both lines.
⚠ **Event keys collide across units** — UM12947 and UM20147 both have an event
`055d4a81`, different sizes, different contents. Anything that stores or
deduplicates must key on `(serial, event_key)`; `MicromateEventRef.uid` is that
pair.
- **🔑 The Series-4 call-home session is captured end to end.** A MITM between a
unit's modem and THOR 1.5.0.29: **101 request frames, 101 responses, 0 bad
checksums, 34,872 B of event data in 65 s.** **Every command in a real ACH
session is one `micromate/protocol.py` already implements** — `POLL`×36,
`BULK_DOWNLOAD`×27, `STATE`×10, `EVENT_RECORD`×8, `EVENT_NEXT`×7,
`STORAGE_RANGE`×4, `MONITOR_STATUS`×3, `ARM_EVENT`×3, `SERIAL`, `EVENT_FIRST`
— bar one. **The last protocol unknown is closed.**
- **🔑 Call-home has TWO paths, and timing decides which runs.** If anything
already holds the modem's single TCP session, the unit's `RADIO RING` travels
**up that existing connection**; if nothing is connected, the modem **dials
out** to a listener. THOR's `UnitWatchDogTimer` reconnects continuously, so
THOR usually holds that slot — which is why probes and relays see "connected,
no reply". **That is contention, not a fault**, and it accounted for a full
afternoon of apparent failures.
- **⚠⚠ `SUB 0xA2` ends a call-home on Series IV — and is CONFIRM ERASE on
Series III.** Same opcode, same `0x5D` response, opposite consequence: on a
MiniMate Plus it is the final step of the erase-all sequence. `minimateplus`
and `micromate` already share a transport, so **any shared path must dispatch
on series before that byte reaches a wire.** Corroborates the firmware string
`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING` found by static analysis.
- **⚠ "Monitor While Calling Home" silently blocks erase, and THOR reports the
session successful anyway.** Both refusals are INFO lines. Delete-after-
download is the necessary fleet setting; a unit left on monitor-while-calling
accumulates events forever while looking healthy.
**Consequence: a receiver cannot rely on erase to manage storage** — the
server-side high-water mark is load-bearing, not an optimisation. Detectable
on any call from `0x06`'s event count plus `0x1C`'s memory fields.
- **⚠ Corrected: `0x06` content[4:8] is the monitor-log count, not a constant.**
Recorded in this file as "9 on both units regardless". It reads 47 against
THOR's `Monitor Log count: 45` twelve minutes earlier on the same unit; both
units simply held 9 records.
- **⚠ Corrected: `SUB 0x49` has a third state.** `0x00` idle, `0x02` monitoring,
and **`0x03` in-call-home** — ten for ten through a session. Exactly why the
rule is *test for non-zero*: `== 0x02` calls a unit mid-call-home idle.
- **THOR rewrites a unit's stored IP from the call-home source address**, so a
relay silently poisons its record of where that unit lives.
- **`CLAUDE.md`'s "Where things stand" refreshed** — it still claimed `micromate/`
had no live client, and that the call-home was the only protocol unknown.
- **🔑 The Series-4 setup block (`0x1A`) is mapped.** Two keypad passes on
UM20147 (10-17, 10-19), every moved byte attributed to a setting the operator
named: record mode `[5]` (`01` Waveform, `02` Manual, `03` Histogram, `04`
Combo -- S3's codes), sample rate `[6:8]`, histogram interval `[8:10]`,
pre-trigger `[12:16]` (f32, **negative** seconds), stop mode `[17]`, record
time `[18:22]`, auto-stop `[23]`, active-sensor / trigger-source bitmasks
`[25]`/`[29]`, scaled distance `[30:38]`, report flags `[39]`, job number
`[40:42]`, notes from `[122]`, trigger level at channel `+30`. Full map and
grades in `docs/micromate_protocol_reference.md`.
- **⚠ The six channel blocks are three geophones, the ACTIVE mic, and two stored
mic setups.** Switching mic type copies block 5 or 6 into block 4. Reading
the mic from 5 or 6 describes a mic that is not fitted.
- **⚠ `0x1A` reads the keypad's edit buffer, live**, and a discard reverts it.
Loading a setup replaces the active config **byte-for-byte**; the setup name
is the only link to the file, and its spelling varies (`.MMB` after a keypad
save, `.mmb` after a load).
- **⚠ The unit converts units with its own constants**: distance ft ÷ 3.2808 to
metres, charge weight lb ÷ **2.21** to kg (not 2.20462). Convert back with
them or 45 lb reads 44.89. Scaled distance is computed for display, not stored.
- **`0x08` is the preferences block, not an event index.** Display units live
there (`content[31]`); switching them moves nothing in `0x1A`.
- **The geophone scale is in the unit's own config.** Channel `+24` reads
`3.1030800342559814`; ÷ 10,000 it equals `_GEO_LSB_IPS` to 1.1e-8 -- an
independent confirmation of a value previously pinned only statistically.
- **`0x1C` content[6] is a ~64 ms sub-second tick**, not a status byte -- read
once a second it aliases into a tidy-looking slow counter. A `0x1C` block is
never byte-identical to itself; compare named fields, never whole blocks.
- **⚠ Rule recorded: never write modem baud rate or modem type remotely.** The
remote link *is* the modem port; a mismatch strands the unit until a site
visit. (Baud is in none of the six blocks we read; nothing writes it.)
- **⚠ Corrected in the reference:** two 16-byte slips in the 9-24 write map --
note labels at `0x7A` (not `0x8A`), channel blocks from `0x6AC` (not `0x6BC`).
- **🔶 Series III, inferred only:** S3's 6-byte "stable anchor"
`be 80 00 00 00 00` sits exactly where Series IV keeps pre-trigger (−0.25 s)
and stop mode (Fixed). An S3 unit in **Auto** stop mode would lose it and
decode no mode / rate / interval / record time. Production is unaffected
(Blastware file ingest). Recorded in `instantel_protocol_reference.md`;
**no code changed** -- one Blastware capture in Auto mode settles it.
### Migration
**None.** No codec change, no waveform-store change, no DB or schema change,
and **no `TOOL_VERSION` bump** — so no `backfill_sidecars.py` /
`backfill_event_shape.py` run is owed. The webapp is served from the image, so
its changes appear after the next `sfm` rebuild.
The Series-4 live client adds **new** modules under `micromate/`
(`framing.py`, `protocol.py`, `client.py`) and appends three dataclasses to
`micromate/models.py`; `micromate/idf_file.py` — the codec — is untouched, and
nothing under `sfm/` or `minimateplus/` changed. The new modules are additive
and nothing imports them yet, so an existing deployment behaves identically.
⚠ The chunk-size and short-chunk changes are **internal to
`micromate/protocol.py`'s download loop**, which no shipped code path calls — the
only callers are the new client and the bench tooling. Nothing in `sfm/` or the
ingest path is affected.
⚠ Likewise `bridges/mm_ach_server.py` and the bench tooling have **no shipped
caller**, and `micromate/client.py` gained only a ring-answering branch inside
that ACH path. Nothing under `sfm/` or `minimateplus/` changed.
⚠ **The `SUB 0xA2` collision above is documentation, not a fix.** `minimateplus`
can already send `0xA2` as the last step of its erase sequence; nothing yet
prevents a future shared path from confusing the two meanings. A guard is
outstanding.
The Series-4 config work adds **one new module**, `micromate/setup_block.py`
(pure, no I/O), a `MicromateSetup` dataclass in `micromate/models.py`, and
`MicromateClient.get_setup()`. All additive; nothing under `sfm/` or
`minimateplus/` changed, and nothing shipped calls the new code. **No codec,
store or DB change, no `TOOL_VERSION` bump, no backfill.** Its 15 test fixtures
are force-added under the gitignored `tests/fixtures/micromate-setup/`.
---
## v0.31.0 — 2026-09-18
**Report parity, and a second way to rescue a runaway unit.** Two threads.
The first closes out Blastware Event/FFT-Report parity: the FFT, the USBM
RI8507 compliance chart and the sensor self-check now render on the event
report, reverse-engineered against BE12844 (MiniMate Plus) and UM (Thor)
events. The sensor check is decoded for **both** series and standardized into
the `.h5` (schema **v2**, a new `/sensor_check` group), so SFM serves it
device-agnostically rather than decoding at report time. The Inspector — an
annotated hex reader for series-3 binaries — is what made the trailing-block
structure findable, and it earned its keep by *ruling out* a stored FFT block
and proving Blastware computes it from the samples.
The second came out of a field emergency. BE12599's connector fault drove its
Tran channel to its trigger level, so the unit recorded back-to-back and dialed
the office ACH server every ~75 s, unreachable the whole time.
`bridges/ach_server.py` gained `--stop-monitoring` / `--disable-ach` /
`--rescue`, which **invert** the recovery: instead of racing a Stop into the
gaps between dial-outs, point the modem's Destination at our own ACH server and
answer the call. Proven in production the same night — the stop landed on the
first call-in and held. See `docs/runbooks/wedged_unit_recovery.md`.
⚠ **This release owes prod a backfill** — see Migration below.
### Added
- **Rescue-on-connect for `bridges/ach_server.py`** — `--stop-monitoring`
(SUB 0x97), `--disable-ach` (SUB 0x2C read → 0x7E write → 0x7F confirm) and
`--rescue` (both). They fire immediately after the startup handshake and
**before** the event walk, so a unit that is recording back-to-back on a
stuck-triggered geophone is quieted as early in the session as possible.
Each action is independently guarded — a failure does not abort the download
— and the outcome is written to `rescue.json` in the session directory.
This inverts the `docs/runbooks/wedged_unit_recovery.md` approach. That
runbook reaches the unit *inbound* and clears the modem's Destination Address
to stop it dialing. When the device is instead wedged mid-modem-init — ALEOS
logs `tcpmode trying to send to invalid socket` and re-runs `Initialize Auto
answer` every ~75 s, orphaning any held inbound session — inbound cannot win.
Pointing the modem's Destination at an `ach_server` and letting the unit call
*us* gives a device-initiated session the modem bridges properly.
⚠ Prefer `--stop-monitoring` alone on first contact. `--disable-ach` stops
the unit calling, which is the only channel to a unit in this state; stopping
the recording ends the call-home loop on its own when ACH is
"after event recorded".
- **Blastware-compatible channel FFT (`waveform_fft`).** Reproduces Blastware's
FFT Report: DC-removed, no window, zero-padded to 4096 (0.25 Hz bins at
1024 sps), single-sided `2/N` amplitude. Matches Blastware's dominant
frequency to the exact bin and the amplitude to report precision across all
28 channels of the 7-event BE12844 oracle set. `channel_spectrum()` /
`dominant_frequency()`; tests in `tests/test_waveform_fft.py`.
- **USBM RI8507 / OSMRE compliance chart on the event-report PDF
(`sfm/compliance.py`).** The velocity-vs-frequency blasting-compliance
scatter Blastware draws in the upper-right of its Event Report: each channel's
significant cycles as `(frequency, peak velocity)` points (zero-crossing
method, so each channel's cloud tops out at its PPV) plotted against the
RI8507 Drywall (0.75 in/s) and plaster (0.50 in/s) limit curves, drawn
continuous (constant-displacement bounds meeting the plateaus — no vertical
steps). Sized and positioned to match a Blastware report, measured off the
reference PDF. A technical breakdown of the curve is in
`docs/ri8507_compliance_curve.md`.
- **Sensor self-check waveforms decoded and drawn — both series.** The little
"Sensor Check" traces (geophone ring-downs — the transducer's damped impulse
response — plus a MicL pulse train, the mic's known-signal gain check) are the
unit's proof its sensors were healthy when it recorded the event.
- **Series-3** (`minimateplus.sensor_check`): four records (`0x3c`–`0x3f`) in
the binary's trailing block, same delta-block codec as the main waveform.
Verified against all 7 BE12844 reports (mic zero-crossing = 20.1 Hz exact;
geophone ring-downs ~7.5 Hz, overswing ~3.5).
- **Series-4** (`micromate.sensor_check`): the same self-test in the Thor IDFW
fixed header — four `01 0e 3c/3d/3e/3f` records (same channel ids) storing
raw int16 traces; three-channel (mic-disabled) units carry only the three
geophones. Validated by shape + cross-event consistency.
- **Standardized into the `.h5`** (`/sensor_check`, schema v2): each series'
decoder attaches the traces to the event at decode, the writer persists
them, and `gather_report_data` reads them back — so SFM renders the strip
(flush against the waveform panel) plus the **Sensor Check → Frequency /
Overswing Ratio** sub-rows without knowing the source instrument.
- Tests: `tests/test_sensor_check.py`, `tests/test_sensor_check_idf.py`,
`tests/test_event_hdf5_sensor_check.py`.
- **Inspector tab in `seismo_lab.py` — annotated hex reader for series-3
binaries (`minimateplus/binary_annotate.py`).** Tiles a raw Blastware file
into labeled spans (header / STRT / body record-chain / trailing metadata +
calibration + sensor-check records / footer) so a binary can be combed by eye.
### Fixed
- **Event-report waveform panel — stacked-lane y-tick collision.** The lanes
touch, so each lane's bottom `-1.0` overprinted the next lane's top `1.0` at
the shared boundary. Prune the extreme ticks so each lane shows clean interior
ticks only.
- **Event-report header — serial+firmware line ran off the page.** The long
`BE##### V ##.##-#.## MiniMate Plus` string overflowed the right margin;
tighter right-column indent + BW's slightly smaller header size so it fits.
---
### Migration
⚠ **The sensor-check needs a backfill.** Existing `.h5` files are schema v1
and carry no `/sensor_check` group, so their reports show no sensor-check strip
until regenerated. `TOOL_VERSION` is bumped to **0.31.0**, so the standard
backfill regenerates every event and picks up the traces with **no `--force`**:
`scripts/backfill_thor_events.py` for series-4 (it already owed a v0.30.0 Thor
backfill — this rides along) and the series-3 sidecar/shape backfill for
MiniMate events. Purely additive — no decoded value changes, and v1 `.h5`
files read fine until then (empty strip). DB backup first, as always.
⚠ Budget **~2 h on the NAS** — ~1.5 files/sec there versus ~85/sec on the dev
box (gzip-4 in `sfm/event_hdf5.py` against a Synology CPU).
Everything else in this release owes nothing: the FFT, the USBM compliance
chart and the `ach_server` rescue flags are additive and read data already on
disk — no schema change, no DB migration.
---
## v0.30.0 — 2026-09-12
**The series-4 correctness release** — the Thor / Micromate counterpart to
v0.26.0's series-3 work. The decoder is now verified per-sample against
Thor's own CSV exports: **459 waveform files, 3,807,158 / 3,807,165 samples
exact** across three independent ground-truth corpora, and production IDFW is
**575/575** with zero truncations and zero decode failures. Series-3
re-verified **unchanged at 14,338/14,338** after every shared-codec change.
⚠ **This release owes the prod store a Thor backfill.** Every stored
series-4 geophone value is **3.3% low**, and histogram peaks from monitoring
runs longer than ~4 hours can be far worse (the interval cap discarded the
tail, frequently the part holding the peak). Run
`scripts/backfill_thor_events.py` — `TOOL_VERSION` is bumped to `0.30.0`, so
regeneration is gated correctly and **no `--force` is needed**. DB backup
first. Series-3 events are untouched by this release and do not need
re-running.
⚠ **Terra-View displays these values.** Series-4 geophone readings will rise
~3.3% after the backfill, and some histogram PPVs will rise a great deal more.
That is a correction, not a regression.
### Fixed — event-report PDF used a per-trace geo Y scale
The waveform plot scaled each geo lane to its own peak, so a small channel
filled its lane and looked as large as a big one, and the `Geo: X in/s/div`
footer reflected only whichever channel was measured first — wrong for the
other two. All three geo lanes now share one symmetric scale (max |sample|
across them, padded, 0.05 in/s floor), matching the event modal and BW's
single amp/div; the footer reflects that shared scale. Mic keeps its own psi
scale. Large events are unchanged.
### Fixed — series-4 (Thor / Micromate) decoder is now per-sample exact
Verified against **Thor's own CSV exports**, which carry a per-sample
four-column block beside every binary (`CSV/<name>.IDFW.csv`) — 1,012 paired
files that had been sitting in the corpus unused. Previous notes asserted
"Thor has no ASCII ground truth", which is why the decoder stayed pinned to a
superseded walker with an unverifiable scale factor.
| metric | before | after |
|---|---|---|
| IDFW per-sample exact | 39.1% | **100.000%** (1,057,536/1,057,536) |
| IDFW files fully exact | 0/153 | **153/153** |
| IDFW PPV median error | −3.32% | **−0.002%** |
| IDFH within 2% of Thor PPV | 51.1% | **100.0%** (858/858) |
| prod IDFW PPV median error (8 units) | −3.3% | **−0.001%** |
| decode cost | — | 6 ms/file |
Four independent root causes:
- **Geo LSB was `0.0003`, should be `0.000310308`** — the old value was Thor's
4-decimal *display rounding* of the LSB mistaken for the LSB, so every
series-4 geophone sample read **3.3% low**. Pinned to ±6e-11 by
intersecting 991,415 rounding constraints; corroborated by the ±full-scale
seed (`±32226`) in unwritten IDFH slots. Applies to IDFH too, which had a
separate (also wrong) `10.0/32768`.
- **IDFH histograms were capped at 250 intervals** — the segment validator
required the interval counter's high byte to be zero, but the counter is a
uint16 cumulative index, so every segment past interval 255 was rejected.
Any run over ~4 hours lost its tail, often the part holding the peak.
540/858 corpus files affected.
- **Record mode `00 00` (raw int16, 10-byte header) was unhandled** — the
record fell through the dispatch, silently dropping each channel's first
512 samples. This produced the long-standing "loud events truncate"
symptom. `MODE_ABSOLUTE` is now also accepted as a segment-0 preamble.
- **Body-offset search matched `00 02 00` inside record headers** — picking a
candidate part-way down the chain, which decodes a rotation-shifted body
that drops each channel's segment 0. The search now anchors on record
headers and takes the chain head.
Also fixes the separately-tracked "UM-series decodes ~1000× low" bug
(`UM11402_20260406130113.IDFW` now matches its device report exactly).
Series-3 re-verified **unchanged at 14,338/14,338 exact** after the shared
`waveform_codec` change.
⚠ **This is a codec change: the Thor store owes a regeneration.** Run
`scripts/backfill_thor_events.py` (bump `TOOL_VERSION` first, or pass
`--force`), DB backup first. All stored series-4 `.h5`/sidecar peaks are
currently ~3.3% low, and histogram peaks for runs over ~4 hours may be
badly low.
⚠ **Thor's histogram PPV has a 0.0050 in/s display floor** — 41.4% of prod
IDFH sidecars report a component PPV larger than their own vector sum. On
quiet files the decoder is now *more* accurate than that reference.
New: `scratch/verify_thor_against_csv.py`, `tests/test_idf_binary_codec.py`
(10 tests, fixtures under `tests/fixtures/thor-idf/`).
### Fixed — mic-disabled (3-channel) units
Verified on a second corpus (`9-10-26-csv-req`: UM11402, UM12947, UM20147) —
**139/139 waveforms per-sample exact (1,273,380 samples), 877/877 histograms
within 2%** (was 66.9% and 56.6%).
- **Waveform body head sat below the scan floor.** A 3-channel unit's shorter
header puts the record chain head at `0x0dba`, under the old
`_BODY_SCAN_FLOOR` of `0x0E00`. The scan couldn't see it and fell through
to the Vert segment-0 record, decoding a body shifted one position around
the channel rotation — Vert came up exactly 512 samples short. Floor
lowered to `0x0C00`; body-offset scoring now accepts 3 channels as "equal"
instead of demanding 4.
- **Histogram interval record is 56 bytes, not 72.** It is
`16 × n_channels + 8`, so mic-disabled units pack 56. Assuming 72 read 7
intervals out of every 10-interval segment then walked off alignment into
garbage decoding as ~10 in/s peaks (errors up to +191,000%). The interval
count now comes from the segment's cumulative counter and the stride is
derived from it; also recovers 4 files that decoded no intervals at all.
Combined across both corpora: **292/292 waveform files, 2,330,916/2,330,916
samples exact.** Production IDFW truncations 41 → 22.
### Fixed — `40 NN` int16 blocks with NN > 8
`data_block_len()` rejected any `40 NN` block with `NN > 0x08`. The cap had
no evidence behind it: every corpus available when it was written used only
NN ∈ {1,2,3,4,8}, so it was never exercised. Loud UM12947 events use NN of
12, 16, 20 … up to 196, and because the block walker stops at the first
unrecognised tag rather than raising, rejecting them surfaced as **silently
short channels** (e.g. Tran 1812 / Vert 2132 / Long 2324 on a file whose
export has 2324 for all three). The bound is the buffer, not a constant.
Verified against Thor exports for UM12947 (2025-07-14 … 09-25, 167
waveforms): length mismatches **22 → 0**, **1,476,242/1,476,249** samples
exact. These are not truncated recordings — the exports carry full sample
counts.
`tests/test_waveform_codec.py` asserted the cap as intended behaviour; that
assertion was wrong and has been replaced with one pinning the opposite,
carrying the evidence.
### Result across all three ground-truth corpora
**459 waveform files, 3,807,158 / 3,807,165 samples exact.** Production
IDFW: **575/575**, zero truncations, zero decode failures, median PPV error
−0.0007% across 8 units. Series-3 re-verified **unchanged at 14,338/14,338**
after every shared-codec change.
The 7 residual samples each differ by one 4th-decimal tick and are **Thor's
own rounding**: intersecting the per-sample rounding constraints over that
corpus is infeasible (the binding pair contradict by 2.3e-11, 7e-5 relative),
so no single linear LSB reproduces every printed value. `_GEO_LSB_IPS` is
already pinned to ~1e-11 — do not retune it to chase these.
---
## v0.29.0 — 2026-09-04
First release to reach prod since **v0.27.0**, so it ships **both** the
+27 -292
View File
@@ -2,7 +2,7 @@
Ground-up Python replacement for **Blastware**, Instantel's Windows-only software for
managing MiniMate Plus seismographs. Connects over direct RS-232 or cellular modem
(Sierra Wireless RV50 / RV55). Current version: **v0.31.0**.
(Sierra Wireless RV50 / RV55). Current version: **v0.29.0**.
Stack-level context — which repo owns what, and how the three project versions
pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
@@ -10,133 +10,10 @@ pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
---
## Where things stand (updated 2026-10-19)
## Where things stand (updated 2026-08-28)
Read this first when picking the project back up.
- **The Series-4 LIVE wire protocol is reverse-engineered end to end
(2026-09-25).** `docs/micromate_protocol_reference.md` is the Series-4
Rosetta Stone, sibling to `instantel_protocol_reference.md`. **A Micromate
answers Series III command frames** — three framing differences: responses
have **no leading `DLE`** (a bare `STX`), `payload[1]` is `0xC5` (Blastware
firmware) or `0x03` (Thor firmware) rather than `0x10`, and the data length
is a **uint16 BE at `payload[8:10]`** (as a byte it under-reads `SUB 0x1A`
by 47x). Read path, event chain, setups, scheduler, monitoring control and
per-event delete are all mapped — **and as of 2026-10-14 so is the inbound
call-home session.** There are no protocol unknowns left.
⚠ **No command has ever been originated against a unit by this project.**
Every write was performed by THOR while we recorded. That line is worth
keeping.
- **✅ `micromate/` HAS a live client (2026-10-02).** `framing.py`,
`protocol.py`, `client.py` + models, **119 tests**, mirroring the
`minimateplus/` stack and reusing its `transport.py` unchanged. Connect over
TCP or serial, identify a unit, read state/clock/battery/memory, list setups,
walk the event chain and download + decode events. **Read-only** — every
write remains mapped-but-unimplemented, deliberately.
Verified on hardware across **both firmware lines** (UM12947 `11.0CB`,
UM20147 `11.0BD`) and **both transports** (USB CDC-ACM and an RX55 over
cellular), byte-identical.
⚠ **The gap is config decoding**, not the protocol: `0x1A` (2,103 B) has
about a dozen fields read; `0x2C`, `0x2E`, `0x08`, `0x01` are fetched and
undecoded. Finishing it needs a bench session varying one setting at a time,
as was done for Series III — not desk work.
- **Config decoding: first keypad pass done (2026-10-17).** 47 snapshots of
UM20147 while settings were changed on its keypad; every byte that moved is
accounted for. `0x1A` content now reads: record mode `[5]` (`01` Waveform,
`02` Manual, `03` Histogram, `04` Combo), sample rate `[6:8]`, histogram
interval `[8:10]` s, pre-trigger `[12:16]` f32 **negative** s, stop mode
`[17]`, record time `[18:22]` f32, auto-stop `[23]`, active-sensor and
trigger-source bitmasks `[25]` / `[29]` (`0x07` geo, `0x08` mic), trigger
level at channel `+30` (geo in/s, mic **psi**). Full table, grades and
method in `docs/micromate_protocol_reference.md` → *The `0x1A` field map
from a keypad pass*.
🔑 **`0x1A` ends in a CRC-16/AUG-CCITT** over `content[0:2088]`, stored BE at
`[2090:2092]` — 47/47 plus a second unit. Thor's write **omits** it (the
unit computes it), so it is a read-side integrity check, not a write
obligation. ✅ Wired in: `micromate.setup_block.crc_ok()` (2026-10-19).
⚠ **The six channel blocks are 3 geophones + the active mic (block 4) + the
stored linear / sound-level mic setups (5, 6).** Read the mic from block 4
and branch on its `+4:8` code (`2` linear, `9` SLM); labels and unit strings
are re-rendered by keypad saves and are not identifiers.
⚠ **`0x1A` reads the keypad's edit buffer live** — unsaved values show while
someone is in the menu; a discard reverts them.
🔶 **Possible Series III bug, inferred only:** S3's 6-byte "stable anchor"
`be 80 00 00 00 00` sits exactly where Series IV keeps pre-trigger (−0.25 s)
+ stop mode (Fixed). An S3 unit in Auto stop mode would then lose the
anchor and decode no mode / rate / interval / record time. One BW capture
in Auto mode settles it — see the 2026-10-17 row in
`instantel_protocol_reference.md`.
Harness: `scratch/mm_config_diff.py watch` (now per-session snapshot labels
and a built-in CRC check). ⚠ `sg dialout -c "..."` is still needed to open
`/dev/ttyACM0` from shells started before the `dialout` membership.
⚠ **When diffing, get the operator's own account of what was pressed** before
labelling a run — twice on 10-17 a run was attributed to the setting that
had been *asked for*, and both were wrong.
Not yet mapped: job number, scaled distance, GPS, aux I/O, SLM options,
four unknown head runs, channel `+46:48`.
**2026-10-19 — setup loading done, plus prefs.** Loading a `.MMB` replaces
the active config **byte-for-byte** (3 loads; only differing fields move, no
load marker). Also measured: job number `[40:42]` + report flags `[39]`
(`0x02` job no., `0x08` scaled distance, `0x01` unknown); distance `[30:34]`
metres and charge weight `[34:38]` kg, **converted with the firmware's own
constants ft ÷ 3.2808 and lb ÷ 2.21** (not 2.2046 — convert back with 2.21 or
45 lb displays as 44.89); notes at `[122+64n]`/`[144+64n]` (the reference's
`0x8A` and `0x06BC` were 16-byte slips, corrected in place).
🔑 **`0x08` is the preferences block, not an event index** — display units
live there (`content[31]`), and switching them moves nothing in `0x1A`.
🔑 **One checksum rule covers `0x1A`, `0x08` and `0x2E`:** `content[0:2]` = N,
CRC-16/AUG-CCITT over `[0:N-2]`, stored at `[N:N+2]`. `0x2C` has none.
`0x2C` session timeout lives at `[118:120]` in an unknown encoding; modem
baud is in none of the six blocks.
⚠ **Never write modem baud or modem type remotely** — the remote link *is*
the modem port; a mismatch strands the unit until a site visit.
"Monitor While Calling Home" is Thor/Blastware-only, so it waits for a THOR
round. Next on config: that THOR round (a many-differences setup + the
`0x2C` fields).
✅ **`MicromateClient.get_setup()` decodes all of the above (2026-10-19)**
— `micromate/setup_block.py`, measured fields only, checksum-verified,
69 tests on 15 real fixtures (`tests/fixtures/micromate-setup/`, force-
added). `bridges/mm_client_check.py` prints it; Brian matched every line
against UM20147's screen.
✅ **SFM speaks Series 4 by serial (phase 1a, 2026-10-20):** `/device/info`,
`/device/monitor/status` and `/device/settings` take `serial` and return one
shared shape for both series through `sfm/device_access/`. Micromate lines
are held open (one call-up, keep-alive 60 s, idle hang-up 5 min, released on
RADIO RING); MiniMates still reconnect per request. Without `serial` the
legacy Series-3 path is unchanged.
✅ **Phase 1b (2026-10-21) lists and downloads events by serial for both
series** -- the MiniMate list comes from headers only (no 5A), and a download
is checked and stored in SFM's DB (`db_event_id`). Bench-checked on UM20147:
5 events, a waveform that verified, a histogram, one call-up for the whole
sequence. ⚠ The MiniMate header walk is **unproven on a unit; a MiniMate
bench check is owed before the branch merges.** Next: 1c (webapp).
- **🔑 ACH / call-home, captured end to end (2026-10-14).** A Micromate signals
`RADIO RING`; **two paths exist and timing decides which**: if anything
already holds the modem's single TCP session the ring rides that connection,
otherwise the modem dials out to a listener. THOR's `UnitWatchDogTimer`
reconnects continuously, so THOR usually holds that slot — which is why
probes and relays see silence. That is contention, not a fault.
⚠⚠ **`SUB 0xA2` ends a call-home on Series IV and is CONFIRM ERASE on
Series III** — same opcode, same `0x5D` response, opposite consequence.
`minimateplus` and `micromate` share a transport; dispatch on series before
that byte reaches a wire.
⚠ **"Monitor While Calling Home" silently blocks erase**, and THOR reports
the session successful anyway. A receiver therefore **cannot rely on erase to
manage storage** — the server-side high-water mark is load-bearing.
⚠ `bridges/mm_ach_server.py` implements the listener path only; it needs to
also hold outbound connections and watch for the ring.
- **Bench tooling for device diagnosis (2026-09-25).** `bridges/mm_probe.py`
distinguishes the four faults THOR reports identically as "disconnected"
(refused / connect timeout / **connected but no reply** / replied) and names
what to try next. `bridges/mm_link.py` is a stand-in for a cellular modem
with a decoded log and fault injection. `scratch/mm_frame_parse.py` exists
because **`S3FrameParser` cannot see Micromate responses at all** — it scans
for `DLE+STX`, which never appears in Series-4 traffic.
- **A Micromate's USB-A host port drives FTDI and CDC-ACM only** — no Prolific,
in either firmware line. TMI buys both Sabrent (FTDI) and Benfei (PL2303)
cables and they are indistinguishable by eye. A PL2303 cable leaves a unit
with **no working modem port at all**; identify by `lsusb` VID, `0403` vs
`067b`. This accounted for a unit that could not be deployed.
- **Series-3 decode is verified per-sample at scale (v0.27.0).** The full DL2
archive decodes **14,338 / 14,338** paired files exactly against their
preserved Blastware ASCII exports — 1,249 waveform + 13,089 histogram, 45
@@ -147,61 +24,9 @@ Read this first when picking the project back up.
Independent corroboration of the 32000-count scale: 19,244 healthy
channel-events sit at a pre-trigger floor of exactly 0.000 (62.7%), 94.5%
within ±1 quantisation unit, median +0.0000 — no zero-point bias.
- **Series-4 (Thor / Micromate) is now verified per-sample (2026-09-10).**
**1,057,536 / 1,057,536** geo samples across all 153 genuine Thor waveform
files reproduce Thor's own CSV export exactly; IDFH peaks are within 2% on
858/858 (median -0.004%). The ground truth was in the corpus all along —
Thor writes `CSV/<name>.IDFW.csv` beside each binary with a **per-sample**
four-column block. Harness: `scratch/verify_thor_against_csv.py`.
Four bugs, all fixed: geo LSB was `0.0003` (display rounding of the real
`0.000310308`, so every sample read **3.3% low**); the IDFH segment
validator required a zero counter high byte, **capping every histogram at
250 intervals**; record mode `00 00` (raw int16) was unhandled, silently
dropping each channel's first 512 samples; and the body-offset search
matched `00 02 00` *inside* record headers, decoding a rotation-shifted
body. IDFW is no longer pinned to `decode_waveform_legacy`.
Series-3 re-verified unchanged at 14,338/14,338 after the shared-codec
change.
- **Mic-disabled (3-channel) units are a distinct shape (2026-09-10).**
Verified on a second corpus (`~/thor-csv-req`, UM11402/UM12947/UM20147):
**139/139** waveforms per-sample exact, **877/877** histograms within 2%.
Two structural differences: the shorter header puts the waveform record
chain head at `0x0dba` (below the old `_BODY_SCAN_FLOOR` of `0x0E00`, so it
was invisible and Vert came up exactly 512 short), and the histogram
interval record is **56 bytes, not 72** — `16 × n_channels + 8`, derived per
segment from the cumulative interval counter, never assumed.
- **`40 NN` blocks are not capped at NN=8 (2026-09-11).** `data_block_len()`
rejected `NN > 0x08`, a guard with no evidence behind it — the corpora
available when it was written only used NN ∈ {1,2,3,4,8}. Loud UM12947
events use NN up to 196, and since the walker stops at the first
unrecognised tag rather than raising, this surfaced as silently short
channels. Verified on 167 UM12947 waveforms: length mismatches 22 → 0,
1,476,242/1,476,249 samples exact.
- **Production IDFW is now 575/575** — zero truncations, zero decode
failures, median PPV error −0.0007% across 8 units (was 41 truncated + 1
failing, −3.3%). Across all three ground-truth corpora: **459 files,
3,807,158/3,807,165 samples exact**; the 7 stragglers differ by one
4th-decimal tick and are Thor's own rounding — no single linear LSB can
reproduce every printed value (the constraints are infeasible by 7e-5
relative), so do NOT retune `_GEO_LSB_IPS`.
- **⚠ KNOWN BUG — the 5A walk breaks once a unit's buffer crosses 64 KB.**
`parse_strt_end_offset()` returns only `(end_key[2] << 8) | end_key[3]`,
discarding the key's page byte. An event starting at `0x0111F2A2` and ending
at `0x0112_1010` therefore reads `end_offset = 0x1010` — *behind* its own
start. The chunk loop then exits before fetching anything and TERM computes
a negative `offset_word`, which `struct.pack(">H", ...)` rejects: the
`/device/events` walk 500s. Reproduced on BE12599 (2026-09-19), which had
78 KB stored and had rolled into page `0x12`.
**Why it hid so long:** every 5A capture the walk was verified against came
from a freshly-erased BE11529 — all three confirmed TERM examples in
`framing.py` (`0x1ABE`, `0x21F2`, `0x417E`) sit inside page `0x11`. Prod is
unaffected: it ingests complete files via BW ACH, never this walk.
**Fixing it has two layers** — the arithmetic (`if end < start: end +=
0x10000`) stops the crash and bounds the loop correctly; carrying the page
byte through the chunk requests (`params[1]` 0x11 -> 0x12, counter rolling
over) needs a BW capture of a spanning event first. Do not ship layer one
alone without a loud truncation warning — a silently short event is the
failure mode this codec has been bitten by repeatedly.
- **Series-4 (Thor / Micromate) is NOT verified.** UM-series sits at ~48%
against device peaks with a ~1.7% systematic bias and a near-zero tail.
Thor IDFW is pinned to `decode_waveform_legacy` deliberately.
- **Open, not blocking:** 14 sensitive-range files show an exact 8x
(= 10.0/1.25) units discrepancy; `scripts/backfill_sidecars.py --force` also
inserts DB rows for store files that have none (one-time per store) and the
@@ -215,9 +40,6 @@ Read this first when picking the project back up.
**v0.27.0 does NOT owe prod a backfill** — verified: the partial-final-block
fix changes 0 of the 10,215 histograms in the prod store (the 4 recovered
files are archive-only and were never ingested).
✅ **The v0.30.0 Series-4 backfill HAS been run on prod (2026-09-25).** Every
stored Series-4 geophone value was ~3.3% low until then; that is corrected and
the job does not need repeating.
- **The "offset" hardware fault has its own journal** --
`docs/offset_investigation.md`. **5 of 45 units (11%)**, and the fault is
**persistent** — it stays until the geophone is serviced. Detect it with
@@ -229,59 +51,7 @@ Read this first when picking the project back up.
`SUB 0x0E` (unimplemented), which may carry those very numbers.
When new information about a protocol is discovered, record it in the matching
reference **in addition to** this document:
| series | document |
|---|---|
| Series III (MiniMate Plus / BlastMate) | `docs/instantel_protocol_reference.md` |
| **Series IV (Micromate / THOR)** | **`docs/micromate_protocol_reference.md`** |
| Thor IDF file format | `docs/idf_protocol_reference.md` |
Both protocol references carry retractions in place rather than deleting what
turned out to be wrong — that convention has already saved re-deriving the same
mistakes twice, so keep it.
---
## Changelog & release convention
**Feature branches do NOT touch `CHANGELOG.md`. Write the entry on `dev`, as
part of finishing the merge, under `## Unreleased`. Cut the version on `dev` in a
dedicated release commit when you are ready to ship to `main`.**
- **The changelog is written on `dev`, never on a feature branch.** With
several branches in flight they all edit the same few lines at the top of
the file and conflict every time. Writing it once, after the merge, also
lets it describe what actually *landed* — including anything that changed
during conflict resolution.
- ⚠ **The merge is not finished until `## Unreleased` is updated.** Same sitting,
not "later" — that is the one failure mode of writing it after the fact.
Reconstruct from the branch's own commit messages:
`git log --oneline dev..<branch>` before you merge, or
`git log --oneline <merge-base>..<branch>` after.
- **No preamble under `## Unreleased`** — just the `### Added` / `### Changed` /
`### Fixed` lists. The themed opening paragraph gets written at release
time, when the whole release is visible and can be named honestly. A theme
written when the first item landed is stale by the third.
- ⚠ **State the operational consequence** on any entry touching the codec, the
waveform store, or the DB — **including when it is "none."** "requires
`backfill_sidecars.py` + `backfill_event_shape.py`, ~2 h on the NAS",
"`TOOL_VERSION` bumped", "no schema change, no migration". Silence is
ambiguous; "none" is information. This repo's changelog is how future-you
learns whether a deploy costs two hours.
- **Releases are cut on judgement, not on a schedule or a merge.** `Unreleased`
is the staging area for whatever is going into the next release; when enough
has accumulated to be worth shipping, it gets a number and a date. Nothing
about a merge to `dev` triggers a release.
- **Cutting a release** is its own `chore(release): vX.Y.Z — <theme>` commit on
`dev`, renaming `## Unreleased` → `## vX.Y.Z — YYYY-MM-DD` and touching:
`CHANGELOG.md`, `pyproject.toml`, the version line in `CLAUDE.md` and
`README.md`, and `minimateplus/event_file_io.py` (`TOOL_VERSION`) **when the
codec changed** — that constant gates `.h5` regeneration.
- **`main` carries only released versions.** No `## Unreleased` section there;
it lands via the `dev` → `main` PR. `main` lagging `dev` by a version is
normal.
When new information about the protocol is discovered, please update the instantel_protocol_reference.md with the findings in addition to this document
---
@@ -350,34 +120,20 @@ should not import from `sfm/`, must not touch a DB, and have no I/O
beyond reading files passed as arguments. Keep them pure — both
tiers can then depend on them without circularity.
#### Thor IDF binary codec (updated 2026-09-10)
#### Thor IDF binary codec (2026-05-28)
`micromate/idf_file.read_idf_file()` decodes both Thor IDFW
(waveform) and IDFH (histogram) binaries. **Verified per-sample
against Thor's own CSV exports** — see
`scratch/verify_thor_against_csv.py`.
(waveform) and IDFH (histogram) binaries.
- **IDFW** uses the series-3 record-chain `decode_waveform_v2()`. The
body offset is **not** fixed: it is `<chain-head record> + 7`, found
by `_find_waveform_body_offset()` anchoring on record headers. All
**153/153** genuine Thor waveform files decode per-sample exact
(1,057,536/1,057,536 samples).
- **IDFH** segment header is `[len_be][0a 00 00 00][counter_be][05 3f]`,
where `counter` is a **uint16 cumulative interval index** — it must
not be constrained to a zero high byte (that capped histograms at 250
intervals). Intervals whose `min > max` on all channels are unwritten
slots carrying a ±full-scale seed and are skipped. 858/858 files land
within 2% of Thor's PPV (median -0.004%).
- **Geo LSB is `0.000310308` in/s per count** (full scale 10.0 in/s =
32226.05 counts). Series-3's 32000-count scale does NOT apply.
- **Record modes** are `02 00` deltas (14 B header), `01 00` absolute,
`00 03` raw 12-bit, and `00 00` **raw int16** (all 10 B headers).
`01 00` and `00 00` are also valid as the implicit segment-0 preamble.
⚠ **Thor's histogram PPV has a 0.0050 in/s display floor.** 41.4% of
prod IDFH sidecars report a component PPV exceeding their own vector
sum — impossible. On quiet files our decode is *more* accurate than
the reference; do not "fix" the decoder to match it.
- **IDFW** reuses `decode_waveform_v2()` on the body at fixed file
offset `0x0f1f`. Sample fidelity is 87–99% byte-exact on quiet
events; loud events hit the BW codec's known walker-stops-early
limitation.
- **IDFH** has its own segment-based decoder: `[len_be][0a 00 00 00]
[00 NN][05 3f]` + N × 72-byte interval records (4 × 16-byte
per-channel min/max/halfp). All 859 Thor IDFH corpus files
decode (181,071 intervals); peak matches sidecar within ~1.8%
(ADC quantization).
The two outlier `BE9439_*` files in the Thor example corpus are
actually Series III Blastware binaries that share the `.IDFW`/`.IDFH`
@@ -413,15 +169,8 @@ minimateplus/ ← Python client library (primary focus)
sfm/server.py ← FastAPI REST server exposing device data over HTTP
seismo_lab.py ← Tkinter GUI (Bridge + Analyzer + Console tabs)
bridges/
mm_probe.py ← name the fault behind a dead unit (4 verdicts, read-only)
mm_link.py ← bench stand-in for a cellular modem, with fault injection
ach_mitm.py ← TCP relay for recording a Series-3 ACH session
docs/
instantel_protocol_reference.md ← Series III protocol spec ("the Rosetta Stone")
micromate_protocol_reference.md ← Series IV protocol spec + THOR's measured behaviour
idf_protocol_reference.md ← Thor IDF file format
instantel_protocol_reference.md ← reverse-engineered protocol spec ("the Rosetta Stone")
CHANGELOG.md ← version history
```
@@ -650,19 +399,15 @@ with zero mismatches. Before: 1 of 1196.
`BE12599/N599LPWJ.980W` @849, `BE9558/K558LOF2.820W` @1485.
(The series-3 histogram codec was fixed 2026-08-25 — see below.)
- ~~**Micromate (UM-series) IDF decode is ~1000× low**~~ — FIXED 2026-09-10.
`UM11402_20260406130113.IDFW` now decodes Tran 1.1168 / Vert 4.3220 /
Long 0.9135, matching the device report exactly. Root cause was the
body-offset search landing inside a record header plus the unhandled
`00 00` record mode, not anything UM-specific.
- ~~**Thor IDF per-count LSB**~~ — RESOLVED 2026-09-10. The 0.983 ratio was
exactly `0.0003 / 0.000310308`. Thor's geo LSB is **0.000310308 in/s per
count** (full scale 10.0 in/s = 32226.05 counts), pinned to ±6e-11 by
intersecting 991,415 rounding constraints from Thor's own exports and
corroborated by the ±full-scale seed (`±32226`) left in unwritten IDFH
interval slots. Series-3's 32000-count scale does **not** carry over.
Note `10.0/32226` is very slightly wrong — see
`docs/idf_protocol_reference.md`.
- **Micromate (UM-series) IDF decode is ~1000× low** — e.g.
`UM11402_20260406130113.IDFW` gives a Tran peak of 0.0009 in/s against
a device-reported 1.1168. The Thor IDF path decodes sanely, so this
is UM-specific.
- **Thor IDF per-count LSB** — after the 32000 geo full-scale
correction, series-4 Thor peaks sit at a median 0.983 of the
device-reported peak (was 0.960 under 32768). Closer but not exact;
Thor likely uses its own per-count LSB rather than the BW
16-count/0.005 in/s convention.
### Decoded sample counts (across the fixture bundle)
@@ -1412,22 +1157,12 @@ for 0x10 records).
GET /device/info?port=COM5 ← serial
GET /device/info?host=1.2.3.4&tcp_port=9034 ← cellular
GET /device/events?host=1.2.3.4&tcp_port=9034&baud=38400
GET /device/events?serial=UM20147&host=...&tcp_port=... ← list with event_id, either series (no 5A on a MiniMate)
POST /device/events/download?serial=UM20147&event_id=...&host=... ← download, check, store; returns db_event_id
GET /device/event?host=1.2.3.4&tcp_port=9034&index=0
GET /device/monitor/status?host=1.2.3.4&tcp_port=9034 ← battery, memory, mode
POST /device/monitor/start?host=1.2.3.4&tcp_port=9034 ← start recording
POST /device/monitor/stop?host=1.2.3.4&tcp_port=9034 ← stop recording
GET /device/settings?serial=UM20147&host=1.2.3.4&tcp_port=9034 ← shared-model settings, either series
POST /device/hangup?host=1.2.3.4&tcp_port=9034 ← release a held Series-4 line
```
`serial=` (UM = Series 4, BE/BA = Series 3) on `/device/info`, `/connect`,
`/monitor/status`, `/settings` returns the shared model, uncached. A `UM` serial on any
other `/device/*` route is 501; any request taking the legacy Series-3 path at a held
Series-4 address is 409.
SFM must run a single uvicorn worker (locks and held lines are per process).
Server retries once on `ProtocolError` for TCP connections (handles cold-boot timing).
### DB read endpoints (query seismo_relay.db written by ach_server.py)
+1 -21
View File
@@ -1,4 +1,4 @@
# seismo-relay `v0.31.0`
# seismo-relay `v0.29.0`
A ground-up replacement for **Blastware** — Instantel's aging Windows-only
software for managing seismographs. Supports both the **MiniMate Plus
@@ -177,25 +177,10 @@ via a thread-safe `_LiveCache` (plain Python dict + `threading.Lock`):
| `POST` | `/device/monitor/start` | Sends SUB 0x96; immediately evicts status cache |
| `POST` | `/device/monitor/stop` | Sends SUB 0x97; immediately evicts status cache |
| `POST` | `/device/call_home` | Reads, patches specified fields, writes back to device |
| `GET` | `/device/settings` | Recording settings in the shared model, either series; serial required; never cached |
| `POST` | `/device/hangup` | Releases a held Series-4 line now; `{"hung_up": bool}` |
| `GET` | `/device/events?serial=` | Lists a unit's events, either series, each with an opaque `event_id` (`serial:key:timestamp`). A MiniMate list reads headers only (no bulk download), on the normal timeout, and gives `record_type: null` (its event record does not say waveform or histogram; not decoded yet). A lost reply fails the list rather than shortening it |
| `POST` | `/device/events/download?serial=&event_id=` | Downloads one event, checks it, and stores it in SFM's database; returns `db_event_id` (file at `GET /db/events/{db_event_id}/blastware_file`). A stale `event_id` (unit erased or wrapped since the list) gets **409** without downloading, for both series; an `event_id` from another unit gets **422**, before any I/O. An event already stored — by an earlier download, or by THOR's watcher — returns its existing row and changes nothing (same `db_event_id`, `inserted: false`, `detail.already_stored: true`). The unit is busy for the whole download; other requests to it get 423 |
**Cache bypass** — All cached endpoints accept `?force=true` to skip the cache and
force a fresh read from the device.
**Serial-named requests (Series 3 and 4)** — `/device/info`, `/device/connect`,
`/device/monitor/status` and `/device/settings` accept `serial` (`UM...` = Series 4
Micromate, `BE...`/`BA...` = Series 3 MiniMate Plus) and return one shared model
for either series. Serial-named requests are **not cached** and ignore `force`.
Without `serial` the legacy Series-3 behaviour is unchanged. Any other `/device/*`
route given a `UM` serial answers **501** ("not supported for Series 4 yet"), and any
request that takes the legacy Series-3 path (no `serial`, or a `BE`/`BA` serial on a
route that does not take one) at an address holding a Series-4 line answers **409**
(use `POST /device/hangup` first). Series-4 lines are held open between requests, so
SFM must run a **single uvicorn worker**: locks and held lines are per process.
**Cache stats** — `GET /cache/stats` returns hit/miss counts and TTL info; `DELETE /cache/device`
clears the device cache immediately.
@@ -511,11 +496,6 @@ Use **com0com** or **VSPD** to create the virtual COM pair on Windows.
## Roadmap (Future)
> **Where it stands *today*** — an honest per-capability maturity assessment,
> what to rely on, known issues, and the gap to a real tool:
> [`docs/sfm_tool_status.md`](docs/sfm_tool_status.md). This section covers
> where it is *going*.
### Strategic direction — where this is going
seismo-relay is being built as a **suite of cooperating components**
-75
View File
@@ -177,8 +177,6 @@ class AchSession:
store: "WaveformStore",
clear_after_download: bool = False,
restart_monitoring: bool = False,
rescue_stop_monitoring: bool = False,
rescue_disable_ach: bool = False,
force_redownload: bool = False,
) -> None:
self.sock = sock
@@ -192,9 +190,6 @@ class AchSession:
self.store = store
self.clear_after_download = clear_after_download
self.restart_monitoring = restart_monitoring
# Rescue actions for a runaway unit — fired before the event walk.
self.rescue_stop_monitoring = rescue_stop_monitoring
self.rescue_disable_ach = rescue_disable_ach
# `force_redownload` tells this session to ignore ach_state and
# re-download every event currently on the device, regardless of any
# (key, timestamp) match. Useful as a manual override when state has
@@ -295,41 +290,6 @@ class AchSession:
root_logger.addHandler(fh)
try:
# ── Step 1.5: rescue actions ──────────────────────────────────────
# Fired BEFORE the event walk so a runaway unit is quieted as early
# in the session as possible. A unit whose geophone sits above the
# trigger threshold records back-to-back and, with ACH set to "after
# event recorded", re-dials every time — saturating its own firmware
# so it never services inbound requests. See
# docs/runbooks/wedged_unit_recovery.md.
#
# Each action is independently guarded: a failure here must not
# abort the download that follows.
if self.rescue_stop_monitoring or self.rescue_disable_ach:
rescue: dict = {"peer": self.peer, "ts": ts}
if self.rescue_stop_monitoring:
log.info("Step 1.5: RESCUE — stop monitoring (SUB 0x97)")
try:
client.stop_monitoring()
rescue["stop_monitoring"] = "ok"
log.info(" stop monitoring OK — device should stop recording")
except Exception as exc:
rescue["stop_monitoring"] = f"failed: {exc}"
log.error(" stop monitoring FAILED: %s", exc)
if self.rescue_disable_ach:
log.info("Step 1.5: RESCUE — disable auto call home (SUB 0x2C/0x7E/0x7F)")
try:
client.set_call_home_config(auto_call_home_enabled=False)
rescue["disable_ach"] = "ok"
log.info(" disable ACH OK — unit should stop calling home")
except Exception as exc:
rescue["disable_ach"] = f"failed: {exc}"
log.error(" disable ACH FAILED: %s", exc)
_save_json(session_dir / "rescue.json", rescue)
# ── Step 2: device info ───────────────────────────────────────────
device_info = None
if not self.events_only:
@@ -787,13 +747,6 @@ def serve(args: argparse.Namespace) -> None:
print(f" Max events per session: {max_ev if max_ev else 'unlimited'}")
print(f" Clear device after download: {'YES' if args.clear_after_download else 'no'}")
print(f" Restart monitoring after download: {'YES' if args.restart_monitoring else 'no'}")
_stop_mon = args.stop_monitoring or args.rescue
_dis_ach = args.disable_ach or args.rescue
print(f" RESCUE stop monitoring on connect: {'YES' if _stop_mon else 'no'}")
print(f" RESCUE disable auto call home: {'YES' if _dis_ach else 'no'}")
if _stop_mon and args.restart_monitoring:
print(" !! --restart-monitoring will re-start the unit after download,")
print(" undoing --stop-monitoring. Drop one of them.")
print(f" Force re-download all (ignore state): {'YES' if args.force_redownload_all else 'no'}")
print(f"{'='*60}")
print(f"\n Point your test unit's ACEmanager call-home settings to:")
@@ -835,8 +788,6 @@ def serve(args: argparse.Namespace) -> None:
store=store,
clear_after_download=args.clear_after_download,
restart_monitoring=args.restart_monitoring,
rescue_stop_monitoring=args.stop_monitoring or args.rescue,
rescue_disable_ach=args.disable_ach or args.rescue,
force_redownload=args.force_redownload_all,
)
t = threading.Thread(target=session.run, daemon=True, name=f"ach-{peer}")
@@ -911,32 +862,6 @@ def parse_args() -> argparse.Namespace:
"DCD on disconnect — without this the unit stays idle after a call-home."
),
)
p.add_argument(
"--stop-monitoring",
action="store_true",
default=False,
help=(
"RESCUE: send SUB 0x97 (stop monitoring) immediately after the "
"handshake, before any event download. Use on a unit that is "
"recording back-to-back because of a stuck-triggered geophone."
),
)
p.add_argument(
"--disable-ach",
action="store_true",
default=False,
help=(
"RESCUE: disable Auto Call Home on the device (SUB 0x2C read → "
"0x7E write → 0x7F confirm) immediately after the handshake. The "
"unit stops dialing out until ACH is explicitly re-enabled."
),
)
p.add_argument(
"--rescue",
action="store_true",
default=False,
help="Shorthand for --stop-monitoring --disable-ach.",
)
p.add_argument(
"--clear-after-download",
action="store_true",
-398
View File
@@ -1,398 +0,0 @@
#!/usr/bin/env python3
"""
mm_ach_server.py — inbound Auto Call Home server for Micromate (Series IV).
**Read-only.** It identifies the unit, reads its state and setups, and walks the
event chain. It does not erase, does not write, does not start or stop
monitoring, and downloads nothing unless asked. Series III's `ach_server.py`
has "rescue actions" that quiet a runaway unit; those are deliberately absent
here, because no command has ever been originated against a unit by this project
and an inbound session is the worst place to break that.
What this is for
----------------
The inbound call-home session is the last unmapped part of the Series IV
protocol.
⚠ **No Micromate has ever been observed calling home.** The 72 `ach_inbound_*`
sessions in `bridges/captures/` are **MiniMate Plus**, and the Series III setup
does not automatically transfer. What we have for Series IV is prior, not
observation:
* The THOR manual §6.2 and the firmware's own strings
(`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING`, `Call Home Deleting
Events`) say the unit dials in and then **waits to be told what to do** —
server-driven, the same shape as Series III's pull model.
* UM12947's `0x2C` dial string reads literally `"RADIO RING"`, which is modem
*answer* vocabulary rather than a destination. With the RV50 debug string
`ATQ1 ATE0 ATS0=2 … RADIO RING` — `ATS0=2` being auto-answer-after-2-rings —
that reads as the unit configuring the modem to **accept** calls, i.e. the
call-*up* path. Which suggests the ACH destination lives in the **modem**,
as it does for Series III.
**If both priors hold, this file is just `MicromateClient` on an inbound socket
and the unknown evaporates.** But there is a specific way it can fail:
⚠ **Those AT strings prove the Micromate talks to the modem over serial.** If it
drives an AT dial for call-home, that exchange happens on the **serial link**,
where a TCP listener sees nothing whatsoever. So a null result here is
informative but ambiguous — it means *either* the trigger did not fire *or* the
interesting part is happening somewhere this tool cannot watch. **If nothing
arrives, the next step is a serial-level capture between the unit and the modem,
not more fiddling with this server.**
**The one question that matters is push vs pull**, and it cannot be answered by
sniffing — only by connecting and keeping quiet. So this server **says nothing
for `--grace` seconds** after accepting. If bytes arrive in that window the unit
speaks first (push) and the server reports exactly what it sent. If the window
passes in silence, it is pull, and the normal handshake follows.
Setup
-----
1. Run this where the unit can reach it:
python3 bridges/mm_ach_server.py --port 12345
2. Point the call-home destination at this machine. **For Series III that
lived in the MODEM's config (ACEmanager), not in the seismograph** — so try
AirLink OS first. If the RX55 can be told to open an outbound TCP session
to `<your IP>:12345` on serial activity, nothing on the instrument needs to
change, which is much the better outcome.
If it has to come from the unit instead, its `SUB 0x2C` call-home block
holds a 40-byte dial string — but **writing that is THOR's job, not ours.**
3. Trigger a call. A scheduled time is the controllable option: repeatable,
needs no monitoring and no thumping. An event-triggered call is the more
interesting session, because it shows how an event gets offered.
4. Watch. Every frame is decoded as it arrives.
⚠ Use a bench unit. Changing a call-home destination means a unit stops
reporting to THOR until it is changed back.
Output per session, in the layout `scratch/mm_frame_parse.py` reads directly:
bridges/captures/mm_ach_<ts>/
raw_bw_<ts>.bin us → unit
raw_s3_<ts>.bin unit → us
session_<ts>.log
session.json what we learned, including push-vs-pull
"""
from __future__ import annotations
import argparse
import datetime
import json
import logging
import socket
import sys
import threading
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from micromate.client import MicromateClient # noqa: E402
from micromate.framing import MicromateFrameParser # noqa: E402
from micromate.protocol import ProtocolError # noqa: E402
from minimateplus.transport import SocketTransport # noqa: E402
log = logging.getLogger("mm_ach")
DEPTHS = ("identify", "state", "events", "download")
# Strings the MODEM puts on the wire, which are not the unit talking.
#
# `CLAUDE.md` already records that an RV50/RV55 "sends \r\nRING\r\n\r\nCONNECT\r\n
# over TCP to the caller even with Quiet Mode enabled". An RX55 on AirLink OS
# says `RADIO RING` instead, space-padded and newline-separated. Observed
# 2026-10-14 from UM12947's modem: four of them and **no CONNECT**.
#
# ⚠ The absence of CONNECT is the useful part. RING means the modem is ringing
# the serial device; CONNECT means something answered. Rings without a CONNECT,
# and no answer to POLL, means the TCP side is fine and the UNIT is not on the
# other end of the serial link.
_MODEM_CHATTER = (b"RADIO RING", b"RING", b"CONNECT", b"NO CARRIER", b"BUSY",
b"NO ANSWER", b"ERROR", b"OK")
class Session:
"""One inbound call. Captures every byte; decides push vs pull first."""
def __init__(self, sock: socket.socket, peer: str, args) -> None:
self.sock, self.peer, self.args = sock, peer, args
self.ts = datetime.datetime.now().strftime("%Y%m%d_%H%M%S")
self.found: dict = {"peer": peer, "started": self.ts}
self._rx: list[bytes] = []
self._tx: list[bytes] = []
self._rx_fh = self._tx_fh = None
# ── byte taps ─────────────────────────────────────────────────────────────
def _tap(self, transport) -> None:
"""Mirror every byte, buffered until we know this is a real unit."""
orig_read, orig_write = transport.read, transport.write
def read(n: int) -> bytes:
data = orig_read(n)
if data:
(self._rx_fh.write(data), self._rx_fh.flush()) if self._rx_fh \
else self._rx.append(data)
return data
def write(data: bytes) -> None:
orig_write(data)
if data:
(self._tx_fh.write(data), self._tx_fh.flush()) if self._tx_fh \
else self._tx.append(data)
transport.read, transport.write = read, write
def _open_capture(self) -> Path:
"""Create the session directory — only once we trust the peer.
A port scanner should leave nothing on disk.
"""
d = Path(self.args.output) / f"mm_ach_{self.ts}"
d.mkdir(parents=True, exist_ok=True)
# Named raw_bw/raw_s3 so scratch/mm_frame_parse.py reads the pair as-is.
self._tx_fh = open(d / f"raw_bw_{self.ts}.bin", "wb")
self._rx_fh = open(d / f"raw_s3_{self.ts}.bin", "wb")
for c in self._tx:
self._tx_fh.write(c)
for c in self._rx:
self._rx_fh.write(c)
self._tx_fh.flush()
self._rx_fh.flush()
self._tx.clear()
self._rx.clear()
return d
# ── the experiment ────────────────────────────────────────────────────────
def _listen_first(self, transport) -> bytes:
"""Say nothing for `--grace` seconds — unless a RING arrives.
Originally this just answered "does the unit speak first?". THOR's ACH
log (2026-10-14) made the question sharper: on seeing `RADIO RING` it
replies in **36 ms**, and with `ReadSerialNumber`, not `POLL`.
We were doing neither — sitting silent for the full 8 s and then sending
POLL. The unit may well have given up long before we spoke. So the
grace window now **ends the moment a ring is seen**, and the caller
answers it the way THOR does.
"""
print(f" listening in silence for up to {self.args.grace:.1f} s "
f"(ends early on a RING)...")
deadline = time.monotonic() + self.args.grace
got = bytearray()
while time.monotonic() < deadline:
chunk = transport.read(4096)
if chunk:
got += chunk
if b"RING" in got:
print(f" RING seen after "
f"{self.args.grace - (deadline - time.monotonic()):.2f} s"
f" — answering immediately, as THOR does")
return bytes(got)
else:
time.sleep(0.02)
return bytes(got)
def run(self) -> None:
print(f"\n=== inbound from {self.peer} at {self.ts} ===")
transport = SocketTransport(self.sock, peer=self.peer)
self._tap(transport)
unsolicited = self._listen_first(transport)
self.found["push"] = bool(unsolicited)
self.found["unsolicited_bytes"] = len(unsolicited)
if unsolicited:
print(f" ** PUSH ** — the unit sent {len(unsolicited)} B unprompted")
print(f" hex : {unsolicited[:64].hex(' ')}")
txt = "".join(chr(c) if 32 <= c < 127 else "." for c in unsolicited[:64])
print(f" ascii : |{txt}|")
hits = [c.decode() for c in _MODEM_CHATTER if c in unsolicited]
if hits:
rings = unsolicited.count(b"RING")
print(f" *** MODEM CHATTER, not the unit: {hits} ***")
self.found["modem_chatter"] = hits
self.found["ring_count"] = rings
if rings and b"CONNECT" not in unsolicited:
print(f" *** {rings} RING(s) and NO CONNECT. ***")
print(" The modem is ringing the serial device and nothing")
print(" is answering. TCP is fine; the UNIT is not on the")
print(" other end of the serial link. Check, in order:")
print(" 1. is the unit cabled to the modem at all?")
print(" 2. cable chipset -- FTDI (0403) or CDC-ACM only,")
print(" never Prolific (067b)")
print(" 3. cold-boot the unit WITH the cable attached;")
print(" its USB-A host port only enumerates at power-on")
self.found["diagnosis"] = "rings without connect: unit not on serial"
frames = MicromateFrameParser().feed(unsolicited)
if frames:
for f in frames:
print(f" frame : SUB=0x{f.sub:02x} "
f"(answers 0x{f.request_sub:02x}) {len(f.data)} B data, "
f"flags=0x{f.flags:02x}, chk "
f"{'ok' if f.checksum_valid else 'BAD'}")
self.found["unsolicited_subs"] = [f"0x{f.sub:02x}" for f in frames]
else:
print(" frame : none parsed — not a response frame. Could be")
print(" a banner (series III sends 'Operating System'")
print(" on cold boot) or a greeting we have not seen.")
else:
print(" ** PULL ** — silence. The unit is waiting to be driven,")
print(" same as series III. Running the normal handshake.")
# From here on it is the ordinary client, which is the point.
mm = MicromateClient(transport, recv_timeout=self.args.timeout)
try:
if b"RING" in unsolicited:
# ⚠ Answer a ring the way THOR does: SERIAL first, not POLL.
# THOR's ACH log shows ReadSerialNumber 36 ms after detecting the
# ring -- it is identifying which unit rang before doing anything
# else. Our POLL-after-8-seconds may simply have been too late
# and the wrong question.
print(" answering the ring with SERIAL (THOR's first move)...")
serial = _cstring(_content(mm.protocol.read_serial()))
print(f" *** THE UNIT ANSWERED: {serial} ***")
self.found["answered_ring"] = True
self.found["ring_serial"] = serial
info = mm.connect()
except ProtocolError as e:
print(f" handshake FAILED: {type(e).__name__}: {e}")
if not unsolicited:
print(" Nothing unprompted AND no answer to POLL — so this is")
print(" neither push nor pull as we understand it. The raw")
print(" capture is the thing to look at; keep it.")
self._finish(self._open_capture())
return
d = self._open_capture()
print(f" {info}")
self.found["device"] = {
"serial": info.serial, "model": info.model,
"firmware_line": info.firmware_line, "monitoring": info.monitoring,
"active_setup": info.active_setup,
}
try:
if DEPTHS.index(self.args.depth) >= DEPTHS.index("state"):
st = mm.get_state()
print(f" {st}")
self.found["state"] = {
"monitoring": st.monitoring,
"device_time": st.device_time.isoformat() if st.device_time else None,
"battery_volts": st.battery_volts,
"memory_free_bytes": st.memory_free_bytes,
}
self.found["setups"] = mm.list_setups()
print(f" {len(self.found['setups'])} setups")
if DEPTHS.index(self.args.depth) >= DEPTHS.index("events"):
refs = mm.list_events()
print(f" {len(refs)} events")
self.found["events"] = []
for r in refs:
print(f" {r}")
self.found["events"].append({
"uid": r.uid, "key": r.key_hex, "size": r.size,
"type": r.record_type, "filename": r.filename,
"timestamp": r.timestamp.isoformat() if r.timestamp else None,
"pvs_ips": r.peak_vector_sum_ips,
})
if self.args.depth == "download":
# Bounded on purpose: an unknown session is a poor place to
# discover that a 70 KB pull takes 30 s and the unit hung up.
for r in refs[: self.args.max_events]:
blob = mm.download_event(r)
out = d / (r.filename or f"{r.key_hex}.bin")
out.write_bytes(blob)
print(f" saved {out.name} ({len(blob)} B)")
except ProtocolError as e:
print(f" session ended early: {type(e).__name__}: {e}")
self.found["error"] = f"{type(e).__name__}: {e}"
self._finish(d)
def _finish(self, d: Path) -> None:
for fh in (self._rx_fh, self._tx_fh):
if fh:
fh.close()
(d / "session.json").write_text(json.dumps(self.found, indent=2))
try:
self.sock.close()
except OSError:
pass
print(f" saved {d}")
print(f" parse with: python3 scratch/mm_frame_parse.py {d}")
def main() -> int:
ap = argparse.ArgumentParser(
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
)
ap.add_argument("--port", type=int, default=12345)
ap.add_argument("--bind", default="0.0.0.0")
ap.add_argument("--output", default="bridges/captures")
ap.add_argument("--timeout", type=float, default=30.0,
help="per-command receive timeout; generous, because an "
"inbound cellular session is the slow case")
ap.add_argument("--grace", type=float, default=5.0,
help="seconds to stay SILENT after accepting, to see whether "
"the unit speaks first. This is the experiment; do not "
"set it to 0 on a first run.")
ap.add_argument("--depth", choices=DEPTHS, default="events",
help="how far to take the session. 'events' walks the chain "
"without downloading (default); 'download' also fetches "
"events, which on cellular is ~0.21 s + bytes/2350 each")
ap.add_argument("--max-events", type=int, default=3,
help="with --depth download, how many to fetch")
ap.add_argument("--once", action="store_true",
help="exit after the first session instead of listening on")
a = ap.parse_args()
# ⚠ Without this, stdout is block-buffered whenever it is not a terminal,
# so the live session commentary sits in a buffer and the log looks EMPTY
# while a call is happening. That cost a confusing few minutes on the first
# real call-in: the session was on disk but nothing was on screen.
try:
sys.stdout.reconfigure(line_buffering=True)
except AttributeError: # pragma: no cover - py<3.7
pass
logging.basicConfig(level=logging.INFO,
format="%(asctime)s %(levelname)-7s %(message)s")
srv = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
srv.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
srv.bind((a.bind, a.port))
srv.listen(5)
print(f"\nMicromate ACH server on {a.bind}:{a.port} (READ-ONLY)")
print(f" depth={a.depth} grace={a.grace}s timeout={a.timeout}s")
print(" waiting for a unit to call in. Ctrl-C to stop.\n")
try:
while True:
sock, addr = srv.accept()
peer = f"{addr[0]}:{addr[1]}"
s = Session(sock, peer, a)
if a.once:
s.run()
return 0
threading.Thread(target=s.run, daemon=False).start()
except KeyboardInterrupt:
print("\nstopped")
return 0
finally:
srv.close()
if __name__ == "__main__":
raise SystemExit(main())
-476
View File
@@ -1,476 +0,0 @@
#!/usr/bin/env python3
"""
mm_client_check.py — exercise the Micromate read client against a real unit.
**Read-only.** It sends POLL, SERIAL, state, monitor status, the setup walk and
(optionally) one event download. It never writes, never erases, never starts or
stops monitoring.
Why it exists
-------------
`micromate/{framing,protocol,client}.py` are verified against captures taken
**over USB**, on **one firmware line** (`11.0CB`). Two things that cannot be
verified that way:
* **the modem path.** An RX55/RV55 bridges serial to TCP transparently, but
it buffers up to ~1 s before forwarding, so a single logical response can
arrive as many small reads. The client reads to frame completion rather
than using idle-gap detection, which should be strictly more robust — but
"should be" is the point of this script.
* **the other firmware line.** `11.0BD` reports `flags = 0x03`, a shorter
model string, and a `SUB 0x1C` block 4 bytes longer. Inferred from a
2026-09-23 sweep; **confirmed on UM20147 2026-09-30** (forward offsets read
a correct battery and clock).
Run it over both paths and diff the two reports. Anything that differs beyond
timings is a finding.
Usage
-----
# over the modem
python3 bridges/mm_client_check.py 63.45.161.30:9034
# over USB / direct serial
python3 bridges/mm_client_check.py /dev/ttyACM0 --baud 115200
# include one event download (still read-only)
python3 bridges/mm_client_check.py <target> --download
⚠ These modems bridge ONE TCP session to serial at a time. If THOR holds the
unit, this will connect and then see nothing — that is contention, not a fault.
`bridges/mm_probe.py` explains that case; disconnect THOR first.
"""
from __future__ import annotations
import argparse
import errno
import os
import select
import sys
import termios
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from micromate.client import MicromateClient, _content # noqa: E402
from micromate.protocol import CHUNK_SIZE, ProtocolError # noqa: E402
from minimateplus.transport import TcpTransport # noqa: E402
class StdlibSerial:
"""Raw serial on stdlib `termios` — no pyserial.
`minimateplus.SerialTransport` needs pyserial, and a bench host is whatever
is to hand. On a PEP 668 distro (Mint 22, Ubuntu 24.04, Debian 12) a plain
`pip install pyserial` is refused outright, so a diagnostic that depends on
it is one you cannot run at the moment you need it. `bridges/mm_link.py`
and `scratch/fake_unit.py` already take this approach; this is the same
~30 lines, and it means the tool runs on a stock Python 3 anywhere.
Not a general replacement for SerialTransport — no flow control, no
parity options, Linux/macOS only. Enough for a Micromate, which is 8N1
with no handshaking.
"""
_BAUD = {9600: termios.B9600, 19200: termios.B19200, 38400: termios.B38400,
57600: termios.B57600, 115200: termios.B115200}
def __init__(self, path: str, baud: int = 115200) -> None:
if baud not in self._BAUD:
raise ValueError(f"unsupported baud {baud}; pick from {sorted(self._BAUD)}")
self.path, self.baud, self.fd = path, baud, None
def connect(self) -> None:
if self.fd is not None:
return
self.fd = os.open(self.path, os.O_RDWR | os.O_NOCTTY | os.O_NONBLOCK)
a = termios.tcgetattr(self.fd)
a[0] = a[1] = a[3] = 0 # raw in/out, non-canonical
a[2] = termios.CS8 | termios.CREAD | termios.CLOCAL # 8N1, ignore modem lines
a[4] = a[5] = self._BAUD[self.baud]
a[6] = list(a[6])
a[6][termios.VMIN] = 0
a[6][termios.VTIME] = 0
termios.tcsetattr(self.fd, termios.TCSANOW, a)
termios.tcflush(self.fd, termios.TCIOFLUSH)
def disconnect(self) -> None:
if self.fd is not None:
os.close(self.fd)
self.fd = None
def is_connected(self) -> bool:
return self.fd is not None
def read(self, n: int) -> bytes:
if self.fd is None:
return b""
r, _, _ = select.select([self.fd], [], [], 0.05)
if not r:
return b""
try:
return os.read(self.fd, n)
except OSError as e:
if e.errno in (errno.EAGAIN, errno.EWOULDBLOCK):
return b""
raise
def write(self, data: bytes) -> None:
if self.fd is None:
raise OSError("port is not open")
while data:
data = data[os.write(self.fd, data):]
class _Timed:
"""Count bytes and time each read, so the two transports can be compared.
With `capture`, also writes the raw byte streams to a `raw_bw_*` /
`raw_s3_*` pair in the layout `scratch/mm_frame_parse.py` already reads --
so a run on an unfamiliar unit can be turned into test fixtures without
setting up a relay.
"""
def __init__(self, inner, capture: str | None = None) -> None:
self._inner = inner
self.reads = 0
self.bytes_in = 0
self.bytes_out = 0
self._bw = self._s3 = None
if capture:
stamp = time.strftime("%Y%m%d_%H%M%S")
d = Path(capture)
d.mkdir(parents=True, exist_ok=True)
self.bw_path = d / f"raw_bw_{stamp}_mm_client_check.bin"
self.s3_path = d / f"raw_s3_{stamp}_mm_client_check.bin"
self._bw = open(self.bw_path, "wb")
self._s3 = open(self.s3_path, "wb")
def close_capture(self) -> None:
for f in (self._bw, self._s3):
if f:
f.close()
def connect(self):
return self._inner.connect()
def disconnect(self):
return self._inner.disconnect()
def is_connected(self):
return self._inner.is_connected()
def write(self, data: bytes):
self.bytes_out += len(data)
if self._bw:
self._bw.write(data); self._bw.flush()
return self._inner.write(data)
def read(self, n: int) -> bytes:
chunk = self._inner.read(n)
if chunk:
self.reads += 1
self.bytes_in += len(chunk)
if self._s3:
self._s3.write(chunk); self._s3.flush()
return chunk
# ⚠ HYPOTHESIS, 6 events. content[11] of the 0x0C record separated 4 waveforms
# from 2 histograms cleanly and was constant within each group. A 4/2 split is
# thin evidence for a byte that could be anything, so _decode() below does NOT
# trust it -- it tries the other suffix on failure and says when the guess was
# wrong. The protocol reference states no type field is known; this may be it.
_TYPE_BYTE = 11
_TYPES = {0x07: ".IDFW", 0x08: ".IDFH"}
def _event_type(record: bytes) -> str:
if len(record) <= _TYPE_BYTE:
return "?"
b = record[_TYPE_BYTE]
return {0x07: "waveform", 0x08: "histogram"}.get(b, f"unknown(0x{b:02x})")
def _decode(blob: bytes, key: bytes, record: bytes) -> None:
"""Decode the downloaded bytes, proving they are a real event file.
read_idf_file() picks waveform vs histogram from the FILENAME SUFFIX, and a
wire download has no filename -- so the suffix has to come from somewhere.
This tries the 0x0C type byte first and the other suffix second; getting a
decode either way proves the chunk assembly, and which one worked is itself
the finding.
"""
import tempfile
from micromate.idf_file import read_idf_file
guess = _TYPES.get(record[_TYPE_BYTE] if len(record) > _TYPE_BYTE else -1, ".IDFW")
order = [guess] + [e for e in (".IDFW", ".IDFH") if e != guess]
for n, ext in enumerate(order):
with tempfile.NamedTemporaryFile(suffix=ext, delete=False) as f:
f.write(blob)
tmp = f.name
try:
res = read_idf_file(tmp)
samples = sum(len(v) for v in getattr(res, "samples", {}).values())
note = "" if n == 0 else f" *** the 0x0C type byte guessed {guess} — WRONG ***"
print(f" decoded OK as {ext}: {samples} samples{note}")
os.unlink(tmp)
return
except Exception as e:
last = f"{ext}: {type(e).__name__}: {e}"
finally:
if os.path.exists(tmp):
os.unlink(tmp)
print(f" decode failed BOTH ways — last: {last}")
out = Path(f"./{key.hex()}.bin")
out.write_bytes(blob)
print(f" saved to {out} for offline analysis")
def _select(refs, which: str):
"""Pick which events `--download` fetches."""
which = which.strip().lower()
if which == "first":
return refs[:1]
if which == "all":
return refs
if which == "largest":
return [max(refs, key=lambda r: r.size)]
return [r for r in refs if r.key_hex.lower() == which]
def _setup_lines(s) -> list[str]:
"""A decoded setup, laid out the way the unit's own menus group it."""
def sensors(geo: bool, mic: bool) -> str:
return " + ".join(n for n, on in (("geophones", geo), ("mic", mic)) if on) or "none"
stop = f"Auto, after {s.auto_stop_after_s} s quiet" if s.auto_record_stop else "Fixed"
if s.mic_type == "linear":
mic = f"linear, trigger {s.mic_trigger_db:.1f} dB ({s.mic_trigger_psi:.5f} psi)"
else:
mic = s.mic_type
sd = (f"on: {s.distance_ft:.1f} ft, {s.charge_weight_lb:.1f} lb"
+ (f" -> {s.scaled_distance:.2f}" if s.scaled_distance else "")
if s.scaled_distance_enabled else "off")
return [
f"record mode {s.record_mode_name}",
f"sample rate {s.sample_rate} sps",
f"histogram interval {s.histogram_interval_s} s",
f"record time {s.record_time_s:g} s stop: {stop}",
f"pre-trigger {s.pretrigger_s:g} s",
f"sensors on {sensors(s.geophones_active, s.mic_active)}",
f"trigger on {sensors(s.trigger_on_geophones, s.trigger_on_mic)}",
"geophone trigger " + " / ".join(f"{v:.3f}" for v in s.geo_trigger_ips) + " in/s",
f"microphone {mic}",
f"job number {s.job_number} ({'on' if s.job_number_enabled else 'off'})",
f"scaled distance {sd}",
*(f"note {k:<15}{v!r}" for k, v in s.notes.items()),
]
def step(label: str, fn, show=None):
"""Run one read, report how long it took and what it returned."""
t0 = time.monotonic()
try:
value = fn()
except Exception as e:
print(f" {label:.<26} FAILED {type(e).__name__}: {e}")
return None
ms = 1000 * (time.monotonic() - t0)
shown = value if isinstance(value, str) else repr(value)
if isinstance(value, list):
shown = f"{len(value)} entries"
if show:
shown = show(value)
print(f" {label:.<26} {ms:7.0f} ms {shown}")
return value
def main() -> int:
ap = argparse.ArgumentParser(
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
)
ap.add_argument("target", help="host:port for TCP, or a serial device path")
ap.add_argument("--baud", type=int, default=115200,
help="serial only; the USB-A/FTDI path runs at 115200. "
"Ignored by the USB-B 'PC' port, which is CDC-ACM "
"and negotiates its own rate.")
ap.add_argument("--timeout", type=float, default=10.0)
ap.add_argument("--download", action="store_true",
help="also walk the event chain and download (read-only)")
ap.add_argument("--event", default="first", metavar="WHICH",
help="which event --download fetches: a key in hex "
"(e.g. 055d4a83), 'first', 'largest', or 'all'. "
"'largest' is the one worth running on an unfamiliar "
"unit -- it is what exercises offsets past 64 KB.")
ap.add_argument("--capture", metavar="DIR",
help="also write a raw_bw_*/raw_s3_*.bin pair to DIR, so "
"this run can become a test fixture. Worth doing on "
"any unit whose firmware line is new to us.")
ap.add_argument("--lenient", action="store_true",
help="do not raise on a bad checksum — for diagnosis only")
a = ap.parse_args()
if ":" in a.target and not Path(a.target).exists():
host, _, port = a.target.rpartition(":")
inner = TcpTransport(host, int(port), connect_timeout=a.timeout)
path = f"TCP {host}:{port}"
else:
inner = StdlibSerial(a.target, baud=a.baud)
path = f"serial {a.target} @ {a.baud}"
transport = _Timed(inner, capture=a.capture)
mm = MicromateClient(transport, recv_timeout=a.timeout,
strict_checksums=not a.lenient)
print(f"\n{path} (read-only: POLL, SERIAL, state, status, setups)\n")
t0 = time.monotonic()
try:
mm.open()
except OSError as e:
print(f" connect.................... FAILED {e}")
return 2
print(f" {'connect':.<26} {1000*(time.monotonic()-t0):7.0f} ms")
try:
info = step("connect() identity", mm.connect)
if info is None:
print("\n Nothing answered. If the port opened but no frame came back,")
print(" check it is actually a Micromate and not another CDC-ACM device —")
print(" /dev/ttyACM* numbering shifts when anything else is plugged in.")
print(" `ls -l /dev/serial/by-id/` names each device and is stable.")
return 3
if info:
print(f" serial={info.serial} model={info.model} "
f"fw={info.firmware_line} monitoring={info.monitoring}")
print(f" active setup={info.active_setup!r}")
if info.firmware_line == "thor":
print(" (11.0BD / Thor line: 0x1C is 4 B longer -- read forward, "
"confirmed 2026-09-30)")
state = step("get_state()", mm.get_state)
if state:
print(f" {state}")
if state.battery_volts and not 2.5 < state.battery_volts < 9.0:
print(f" *** battery {state.battery_volts} V is impossible — "
f"this is the from-the-end offset bug. ***")
if state.device_time is None:
print(" *** device clock did not decode — dump raw below. ***")
print(f" raw 0x1C content: {_content(state.raw).hex(' ')}")
setup = step("get_setup()", mm.get_setup, show=lambda s: f"{s.name} (checksum ok)")
if setup:
print(" check each line against the unit's screen:")
for line in _setup_lines(setup):
print(f" {line}")
setups = step("list_setups()", mm.list_setups)
if setups:
print(f" first={setups[0]!r} last={setups[-1]!r}")
# ── SUB 0x06: event count, and (likely) the monitor-log count ─────
# content[0:4] is the event count: 3/3 against the chain walk, and THOR's
# own ReadEventRecordCount agrees. content[4:8] was once recorded as "a
# constant 9" -- it read 47 during the 10-14 ACH session against THOR's
# "Monitor Log count: 45", so it is very likely the monitor-log count.
# Still graded a strong candidate, not settled (reference, 10-14).
claimed = None
raw06 = step("0x06 storage range", mm.protocol.read_storage_range)
if raw06:
c = _content(raw06)
claimed = int.from_bytes(c[0:4], "big")
print(f" content[0:4] = {claimed} <- event count")
print(f" content[4:8] = {int.from_bytes(c[4:8],'big')} "
f"<- likely the monitor-log count (strong candidate)")
if a.download:
print("\n event chain (read-only), via MicromateClient:")
t1 = time.monotonic()
refs = mm.list_events() # walks to the sentinel
walk = time.monotonic() - t1
print(f" {len(refs)} events in {walk:.1f} s "
f"({walk/max(len(refs),1):.2f} s each, 3 round trips per event)")
if claimed is not None:
verdict = ("✓ AGREES" if claimed == len(refs)
else f"✗ DISAGREES (0x06 said {claimed})")
print(f" 0x06 count vs chain length: {verdict}")
for ref in refs:
print(f" {ref}")
print(f" would be filed as {ref.filename}")
if refs:
wanted = _select(refs, a.event)
if not wanted:
print(f"\n --event {a.event!r} matched nothing")
else:
print(f"\n download ({len(wanted)} of {len(refs)}, "
f"THOR's interleaved order):")
want_keys = {r.key_hex for r in wanted}
# iter_events() walks the chain; download only the selected
# events, at the cursor position THOR would be at.
for ref in mm.iter_events():
if ref.key_hex not in want_keys:
continue
# ⚠ Use the size actually requested. This printed
# `size // 1024` -- THOR's chunk size -- while the
# download used the 16 KB default, so it reported 71
# requests for a walk that made 5. A diagnostic that
# misreports what it did is worse than one that says
# nothing, and this one nearly had me reading a working
# 16 KB download as a broken 1 KB one.
n_chunks = -(-ref.size // CHUNK_SIZE)
note = (" <- past 64 KB, carries into params[1]"
if ref.size > 0x10000 else "")
t1 = time.monotonic()
try:
result = mm.get_event(ref) # verify=True
except Exception as e:
print(f" {ref.key_hex} {ref.size:7} B "
f"FAILED {type(e).__name__}: {e}")
continue
dt = max(time.monotonic() - t1, 1e-6)
n = sum(len(v) for v in getattr(result, "samples", {}).values())
err = mm.decode_error(ref, result)
check = ("PVS %+.4f%%" % (100 * err) if err is not None
else "PVS n/a (histogram)")
print(f" {ref.key_hex} {ref.record_type:9} "
f"{ref.size:7} B {n_chunks:3} req @ {CHUNK_SIZE} B "
f"{dt:5.1f} s {n:6} samples {check}{note}")
except ProtocolError as e:
print(f"\n ABORTED {type(e).__name__}: {e}")
return 3
finally:
mm.close()
transport.close_capture()
if a.capture:
print(f"\n capture written:\n {transport.bw_path}\n {transport.s3_path}")
print(" parse it with: python3 scratch/mm_frame_parse.py "
f"{transport.bw_path} {transport.s3_path}")
elapsed = time.monotonic() - t0
print(f"\n transport: {transport.reads} reads, "
f"{transport.bytes_in} B in, {transport.bytes_out} B out, "
f"{elapsed:.1f} s total")
print(" Measured 2026-09-29, UM12947, same unit both ways:")
print(" USB-B (CDC-ACM) 83 reads list_setups 0.46 s download 394 KiB/s")
print(" RX55 (TCP) 36 reads list_setups 16.05 s download 1.6 KiB/s")
print(" The modem needs FEWER reads, not more -- it buffers ~1 s and then")
print(" forwards one large segment, where CDC-ACM delivers many small ones.")
print(" Cellular cost, measured: ~0.21 s per request + ~2,350 B/s.")
print(" So STATUS work is round-trip bound (minimise commands) but a")
print(" DOWNLOAD is throughput bound -- 16 KB chunks save ~30% on a large")
print(" event, not 14x. An earlier note claiming cost was independent of")
print(" payload was fitted only to sub-1 KB responses.\n")
return 0
if __name__ == "__main__":
raise SystemExit(main())
-338
View File
@@ -1,338 +0,0 @@
#!/usr/bin/env python3
"""
mm_link.py — a "perfect modem" between THOR and a Micromate, with a readable
log and deliberate fault injection.
Why
---
THOR gives almost no visibility into a connection: a refresh button, two poll
intervals, and no way to see whether a check succeeded, timed out, or was never
sent. When a unit "won't stay connected" there is nothing to look at.
This sits where the cellular modem would sit and answers the question directly:
* **What is THOR actually doing?** Every frame is decoded and timestamped —
`POLL`, `MONITOR_STATUS`, `SETUP_NAME_READ` — not a hex dump.
* **Is it even trying?** Silence is visible: the log shows gaps.
* **How does it behave when the link misbehaves?** Faults can be injected on
demand, which a real cell link will not do on cue.
Point THOR at this host and port exactly as if it were a modem (Communication:
TCP, IP: <this host>, Port: <--listen>).
Fault injection
---------------
Write a mode into the control file (default `mm_link.ctl`) and it takes effect
on the next byte:
echo pass > mm_link.ctl # normal relay
echo blackhole > mm_link.ctl # TCP stays up, bytes are swallowed
echo drop > mm_link.ctl # close the connection abruptly (RST-ish)
echo delay:2.0 > mm_link.ctl # forward, but 2 s late in both directions
echo onewaydev > mm_link.ctl # THOR->unit passes, unit->THOR is swallowed
**`blackhole` is the one that matters.** It reproduces the classic cellular
failure: the socket is still open as far as both ends are concerned, but nothing
crosses. A client that relies on TCP to tell it the peer is gone will sit there
until the OS keepalive fires — which by default is about two hours.
Usage
-----
python3 bridges/mm_link.py --serial /dev/ttyACM0 --baud 115200 \\
--listen 12345 --logdir ~/mm-captures
Writes, per session:
<logdir>/mmlink_<ts>/session.log decoded, timestamped, human-readable
<logdir>/mmlink_<ts>/raw_bw.bin THOR -> unit, raw
<logdir>/mmlink_<ts>/raw_s3.bin unit -> THOR, raw
The raw pair loads straight into `scratch/mm_frame_parse.py`.
"""
from __future__ import annotations
import argparse
import datetime
import os
import socket
import sys
import threading
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent / "scratch"))
try:
from mm_frame_parse import SUBNAME, destuff # noqa: F401
except Exception: # pragma: no cover
SUBNAME = {}
import errno
import select
import termios
DLE, STX, ETX, ACK = 0x10, 0x02, 0x03, 0x41
_BAUD = {9600: termios.B9600, 19200: termios.B19200, 38400: termios.B38400,
57600: termios.B57600, 115200: termios.B115200}
class SerialPort:
"""Minimal raw serial port on stdlib termios — no pyserial dependency.
The bench hosts are whatever is to hand; requiring a pip install on someone
else's machine is a poor trade for the ~30 lines this saves.
"""
def __init__(self, path: str, baud: int):
if baud not in _BAUD:
raise ValueError(f"unsupported baud {baud}; pick one of {sorted(_BAUD)}")
self.fd = os.open(path, os.O_RDWR | os.O_NOCTTY | os.O_NONBLOCK)
a = termios.tcgetattr(self.fd)
a[0] = 0 # iflag: no translation
a[1] = 0 # oflag: raw
a[2] = termios.CS8 | termios.CREAD | termios.CLOCAL # cflag: 8N1, ignore modem lines
a[3] = 0 # lflag: non-canonical, no echo
a[4] = a[5] = _BAUD[baud]
a[6] = list(a[6])
a[6][termios.VMIN] = 0
a[6][termios.VTIME] = 0
termios.tcsetattr(self.fd, termios.TCSANOW, a)
termios.tcflush(self.fd, termios.TCIOFLUSH)
def read(self, n: int) -> bytes:
r, _, _ = select.select([self.fd], [], [], 0.2)
if not r:
return b""
try:
return os.read(self.fd, n)
except OSError as e:
if e.errno in (errno.EAGAIN, errno.EWOULDBLOCK):
return b""
raise
def write(self, data: bytes) -> None:
while data:
try:
data = data[os.write(self.fd, data):]
except OSError as e:
if e.errno in (errno.EAGAIN, errno.EWOULDBLOCK):
select.select([], [self.fd], [], 0.2)
continue
raise
def close(self) -> None:
try:
os.close(self.fd)
except OSError:
pass
def name_of(sub: int, is_request: bool) -> str:
if is_request:
return SUBNAME.get(sub, f"SUB_{sub:02X}")
return "rsp " + SUBNAME.get(0xFF - sub, f"SUB_{0xFF - sub:02X}")
class FrameSniffer:
"""Accumulate bytes and report complete frames, without altering the stream."""
def __init__(self, is_request: bool):
self.is_request = is_request
self.buf = bytearray()
def feed(self, data: bytes):
"""Yield (sub, payload_len) for each complete frame seen."""
self.buf.extend(data)
while True:
start = -1
for i, b in enumerate(self.buf):
if self.is_request and b == ACK and i + 1 < len(self.buf) and self.buf[i + 1] == STX:
start = i
break
if not self.is_request and b == STX:
start = i
break
if start < 0:
if len(self.buf) > 8192:
del self.buf[:-16]
return
j = start + (2 if self.is_request else 1)
end = -1
while j < len(self.buf):
if self.buf[j] == DLE and j + 1 < len(self.buf):
j += 2
continue
if self.buf[j] == ETX:
end = j
break
j += 1
if end < 0:
return # wait for more bytes
body = self.buf[start:end + 1]
del self.buf[:end + 1]
# SUB sits at a fixed spot past the leading framing -- but it is
# DLE-escaped when its own value is 0x02/0x03/0x04/0x10, so a raw
# read reports 0x10 for those. SUB 0x02 was being logged as
# "SUB_10" until this was handled.
off = 5 if self.is_request else 3
if len(body) > off:
sub = body[off]
if sub == DLE and len(body) > off + 1:
sub = body[off + 1]
yield sub, len(body)
class Link:
def __init__(self, args):
self.args = args
self.mode = "pass"
self.delay = 0.0
self.ctl = Path(args.control)
self.session: Path | None = None
self.log_fh = None
self.raw = {}
self.t0 = time.time()
self.counts = {}
# ── logging ────────────────────────────────────────────────────────────
def open_session(self):
ts = datetime.datetime.now().strftime("%Y%m%d_%H%M%S")
self.session = Path(self.args.logdir) / f"mmlink_{ts}"
self.session.mkdir(parents=True, exist_ok=True)
self.log_fh = open(self.session / "session.log", "a", buffering=1)
self.raw = {
"bw": open(self.session / "raw_bw.bin", "ab"),
"s3": open(self.session / "raw_s3.bin", "ab"),
}
self.say(f"=== session {ts} — serial {self.args.serial} @ {self.args.baud} ===")
def say(self, text: str):
line = f"{datetime.datetime.now().strftime('%H:%M:%S.%f')[:-3]} {text}"
print(line, flush=True)
if self.log_fh:
self.log_fh.write(line + "\n")
# ── control file ───────────────────────────────────────────────────────
def poll_control(self):
while True:
try:
if self.ctl.exists():
want = self.ctl.read_text().strip().lower()
if want.startswith("delay:"):
d = float(want.split(":", 1)[1])
if ("delay", d) != (self.mode, self.delay):
self.mode, self.delay = "delay", d
self.say(f"*** MODE -> delay {d}s ***")
elif want and want != self.mode:
self.mode, self.delay = want, 0.0
self.say(f"*** MODE -> {want} ***")
except Exception:
pass
time.sleep(0.25)
# ── the relay ──────────────────────────────────────────────────────────
def pump(self, src, dst, tag: str, is_request: bool, stop: threading.Event):
sniff = FrameSniffer(is_request)
arrow = "THOR->unit" if is_request else "unit->THOR"
last = time.time()
while not stop.is_set():
timed_out = False
try:
data = src.recv(4096) if isinstance(src, socket.socket) else src.read(4096)
except TimeoutError:
timed_out = True
# socket.timeout subclasses OSError, so it MUST be caught first.
# Treating it as a dead socket closes the connection after 200 ms
# of quiet -- which is exactly what `blackhole` produces, so the
# relay killed the link it was supposed to be faking a fault on.
data = b""
except OSError:
break
if isinstance(src, socket.socket) and data == b"" and not timed_out:
self.say(f"{arrow}: peer closed the connection")
break
if not data:
if time.time() - last > self.args.quiet_after and self.counts:
self.say(f"--- {self.args.quiet_after:.0f}s with no traffic ---")
last = time.time()
continue
last = time.time()
self.raw[tag].write(data)
self.raw[tag].flush()
for sub, ln in sniff.feed(data):
label = name_of(sub, is_request)
self.counts[label] = self.counts.get(label, 0) + 1
self.say(f"{arrow} {label:<20} ({ln} B)"
+ ("" if self.mode == "pass" else f" [mode={self.mode}]"))
mode = self.mode
if mode == "drop":
self.say(f"{arrow}: DROPPING the connection (fault injection)")
stop.set()
break
if mode == "blackhole":
continue # swallow, keep the socket open
if mode == "onewaydev" and not is_request:
continue # unit's replies never reach THOR
if mode == "delay" and self.delay:
time.sleep(self.delay)
try:
if isinstance(dst, socket.socket):
dst.sendall(data)
else:
dst.write(data)
except OSError:
break
stop.set()
def serve(self):
srv = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
srv.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
srv.bind(("0.0.0.0", self.args.listen))
srv.listen(5)
self.open_session()
self.say(f"listening on 0.0.0.0:{self.args.listen} control file: {self.ctl}")
self.say("point THOR at this host/port as Communication=TCP")
threading.Thread(target=self.poll_control, daemon=True).start()
while True:
conn, addr = srv.accept()
conn.settimeout(0.2)
self.say(f"+++ THOR connected from {addr[0]}:{addr[1]} +++")
try:
ser = SerialPort(self.args.serial, self.args.baud)
except OSError as e:
self.say(f"!!! cannot open {self.args.serial}: {e}")
conn.close()
continue
stop = threading.Event()
ts = [
threading.Thread(target=self.pump, args=(conn, ser, "bw", True, stop), daemon=True),
threading.Thread(target=self.pump, args=(ser, conn, "s3", False, stop), daemon=True),
]
for t in ts:
t.start()
for t in ts:
t.join()
conn.close()
ser.close()
summary = ", ".join(f"{k}x{v}" for k, v in sorted(self.counts.items()))
self.say(f"--- connection closed. frames this session: {summary or 'none'} ---")
def main():
ap = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
ap.add_argument("--serial", default="/dev/ttyACM0")
ap.add_argument("--baud", type=int, default=115200)
ap.add_argument("--listen", type=int, default=12345)
ap.add_argument("--logdir", default=os.path.expanduser("~/mm-captures"))
ap.add_argument("--control", default="mm_link.ctl")
ap.add_argument("--quiet-after", type=float, default=30.0,
help="log a marker after this many seconds of silence")
Link(ap.parse_args()).serve()
if __name__ == "__main__":
main()
-239
View File
@@ -1,239 +0,0 @@
#!/usr/bin/env python3
"""
mm_probe.py — answer "why can't we reach this unit?" in one command.
THOR reports a failed connection as "disconnected" and nothing else. That single
word covers at least four completely different faults with four different fixes,
and telling them apart is the difference between a modem reboot and a site visit:
* **connection refused** something answered and said no — wrong port, or the
modem is refusing a further session
* **connect timed out** nothing answered at all — trusted-IP whitelist,
firewall, or the modem is off the network
* **connected, no reply** the MODEM answered but the unit did not. The TCP
path is fine; the modem is not forwarding to serial.
This is the signature of a wedged transparent-TCP
session, and it is the one THOR cannot distinguish
from any of the others
* **replied** the unit is alive; the problem is upstream software
Read-only. It sends `POLL`, then optionally `SERIAL` and the state read — the
same three commands THOR's own connection check uses — and never writes.
Usage
-----
python3 bridges/mm_probe.py 63.45.161.30:9034
python3 bridges/mm_probe.py 10.0.0.8:12345 --timeout 5
python3 bridges/mm_probe.py <host:port> --slots 3
`--slots N` opens N connections at once and reports how many the far end accepts.
A transparent-TCP modem typically serves **one** session; if the first succeeds
and the rest are refused or hang, that confirms the single-slot behaviour and
explains why a leaked session takes a unit offline until the slot frees.
Works for both series: a Series III reply opens `DLE STX`, a Micromate reply
opens with a bare `STX`, so the probe also tells you which one answered.
"""
from __future__ import annotations
import argparse
import socket
import sys
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from minimateplus.framing import build_bw_frame # noqa: E402
DLE, STX, ETX = 0x10, 0x02, 0x03
def destuff(raw: bytes) -> bytes:
"""Strip framing and DLE escapes; return the payload without its checksum."""
i = 1 if raw and raw[0] == STX else (2 if len(raw) > 1 and raw[1] == STX else 0)
out = bytearray()
while i < len(raw):
b = raw[i]
if b == DLE and i + 1 < len(raw):
out.append(raw[i + 1])
i += 2
continue
if b == ETX:
break
out.append(b)
i += 1
return bytes(out[:-1]) if len(out) > 1 else b""
# Reads are two-step on Series III: a probe at offset 0, then a data read at the
# block's length. THOR sends these offsets, and they also work on a Micromate.
OFFSETS = {0x5B: 0x0030, 0x15: 0x000A, 0x49: 0xFFFF}
def exchange(sock: socket.socket, sub: int, timeout: float) -> tuple[bytes, float]:
sock.sendall(build_bw_frame(sub, OFFSETS.get(sub, 0)))
t0 = time.time()
buf, deadline = b"", t0 + timeout
sock.settimeout(0.3)
while time.time() < deadline:
try:
chunk = sock.recv(4096)
if not chunk:
break
buf += chunk
if buf.endswith(bytes([ETX])) and len(buf) > 8:
break
except TimeoutError:
continue
except OSError:
break
return buf, time.time() - t0
def step(n: int, label: str, result: str) -> None:
print(f" [{n}] {label:.<28} {result}")
def probe(host: str, port: int, timeout: float) -> int:
print(f"\ntarget {host}:{port} (read-only: POLL, SERIAL, state)\n")
# ── 1. TCP ────────────────────────────────────────────────────────────
t0 = time.time()
try:
sock = socket.create_connection((host, port), timeout=timeout)
except ConnectionRefusedError:
step(1, "TCP connect", f"REFUSED after {1000*(time.time()-t0):.0f} ms")
print("\nverdict: something answered and actively refused.")
print(" Not a silent firewall drop — the host is reachable.")
print(" Wrong port, the service is down, or the modem is refusing")
print(" an additional session because its one slot is in use.")
return 2
except (TimeoutError, socket.timeout):
step(1, "TCP connect", f"TIMED OUT after {time.time()-t0:.1f} s")
print("\nverdict: nothing answered at all.")
print(" A silent drop, which is what a trusted-IP whitelist looks")
print(" like — it discards rather than refuses. Check the modem's")
print(" Trusted IPs (and note a VPN changes the IP you arrive from),")
print(" the firewall, and whether the modem is on the network.")
return 3
except OSError as e:
step(1, "TCP connect", f"FAILED: {e}")
return 4
step(1, "TCP connect", f"ok ({1000*(time.time()-t0):.0f} ms)")
# ── 2. POLL ───────────────────────────────────────────────────────────
try:
raw, dt = exchange(sock, 0x5B, timeout)
except OSError as e:
step(2, "POLL", f"send failed: {e}")
sock.close()
return 4
if not raw:
step(2, "POLL", f"NO REPLY in {timeout:.1f} s")
print("\nverdict: the MODEM answered but the unit did not.")
print(" TCP is fine end to end — something accepted the connection.")
print(" What is missing is the serial side. Two quite different")
print(" causes produce this, and they are NOT distinguishable from")
print(" here:")
print("\n 1. SOMEONE ELSE HOLDS THE SESSION. These modems bridge ONE")
print(" TCP session to serial at a time. A second connection is")
print(" accepted and then simply not forwarded. Confirmed 2026-09-26:")
print(" with THOR connected this probe saw exactly this; the moment")
print(" THOR disconnected the same probe returned the serial number.")
print(" ** Check whether THOR (or anything else) has the unit first. **")
print("\n 2. The serial path is genuinely broken — a stale session the")
print(" modem never released, a cable the unit cannot enumerate, or")
print(" a unit that is off.")
print("\n Try, in order:")
print(" 1. Disconnect any other client and re-probe. If it answers,")
print(" it was contention, not a fault.")
print(" 2. The cable's chipset. A Micromate drives FTDI and CDC-ACM")
print(" only — a Prolific PL2303 gives it no serial port at all.")
print(" lsusb: FTDI is 0403, Prolific 067b.")
print(" 3. Power-cycle the UNIT with the cable attached (hold power")
print(" 5 s, through the two-stage prompt). Its USB host rescans")
print(" on cold boot; it may not on hot-swap.")
print(" 4. AirLink OS -> TCP Idle Timeout. If 0/disabled, a stale")
print(" session holds the slot indefinitely. 2 minutes is the")
print(" value this project standardised on.")
sock.close()
return 5
series = "Series III (DLE STX)" if raw[0] == DLE else "Micromate (bare STX)"
step(2, "POLL", f"reply {len(raw)} B in {1000*dt:.0f} ms")
p = destuff(raw)
ok = len(p) > 3 and p[2] == 0xFF - 0x5B
step(3, "frame", f"{'valid' if ok else 'MALFORMED'}, {series}")
if not ok:
print("\nverdict: something replied, but not a seismograph.")
print(" Another service is on this port, or the modem is in a mode")
print(" that injects its own text (check Quiet Mode / AT echo).")
print(f" first bytes: {raw[:16].hex(' ')}")
sock.close()
return 6
# ── 3. identity + state ───────────────────────────────────────────────
for n, (sub, label) in enumerate(((0x15, "serial"), (0x49, "state")), start=4):
try:
r, dt = exchange(sock, sub, timeout)
d = destuff(r)[5:]
if sub == 0x15:
# serial is a null-terminated run; a further field follows it
serial = bytes(d[11:]).split(b"\x00")[0]
step(n, label, serial.decode("ascii", "replace") or "(empty)")
else:
step(n, label, "MONITORING" if len(d) > 11 and d[11] else "idle")
except OSError:
step(n, label, "no reply")
sock.close()
print("\nverdict: the unit is alive and answering.")
print(" If THOR still shows it disconnected, the fault is in THOR, not")
print(" the network or the device.")
return 0
def slots(host: str, port: int, n: int, timeout: float) -> None:
print(f"\nopening {n} simultaneous connections to {host}:{port}\n")
held = []
for i in range(n):
try:
s = socket.create_connection((host, port), timeout=timeout)
held.append(s)
step(i + 1, f"connection {i+1}", "accepted")
except ConnectionRefusedError:
step(i + 1, f"connection {i+1}", "REFUSED")
except (TimeoutError, socket.timeout):
step(i + 1, f"connection {i+1}", "timed out")
except OSError as e:
step(i + 1, f"connection {i+1}", f"failed: {e}")
print(f"\n{len(held)} of {n} accepted.")
if len(held) == 1:
print(" Single-slot behaviour confirmed — this far end serves ONE")
print(" session at a time. A connection that is never closed takes")
print(" the unit offline until the idle timeout frees the slot.")
for s in held:
s.close()
def main() -> int:
ap = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
ap.add_argument("target", help="host:port, e.g. 63.45.161.30:9034")
ap.add_argument("--timeout", type=float, default=10.0)
ap.add_argument("--slots", type=int, metavar="N",
help="open N simultaneous connections to test single-slot behaviour")
a = ap.parse_args()
host, _, port = a.target.rpartition(":")
if not host:
ap.error("target must be host:port")
if a.slots:
slots(host, int(port), a.slots, a.timeout)
return 0
return probe(host, int(port), a.timeout)
if __name__ == "__main__":
raise SystemExit(main())
+1 -223
View File
@@ -6,15 +6,7 @@ Series IV event-file format. Sibling to
Series III "Rosetta Stone") — this doc holds what we know so far and
the open questions still to crack.
> ⚠ **The "Status (2026-05-28)" block below is SUPERSEDED.** Its geo LSB
> (0.0003), its IDFH scale (`/32768 × 10`), its fixed body offset (`0x0f1f`)
> and its "87–99% byte-exact / loud events truncate" caveat were all wrong or
> incomplete. See **[Verified against Thor's own exports
> (2026-09-10)](#verified-against-thors-own-exports-2026-09-10)** — the
> decoder is now per-sample exact on 1,057,536/1,057,536 samples. The block
> is kept only for the reverse-engineering trail.
**Status (2026-05-28, SUPERSEDED):** ASCII text sidecar fully decoded (1,014
**Status (2026-05-28):** ASCII text sidecar fully decoded (1,014
sample files round-trip). **Thor IDFW** binary now decodes via
`micromate.idf_file.read_idf_file()` — reuses the BW segment-rotated
block codec verbatim at fixed body offset `0x0f1f`; metadata (serial,
@@ -52,220 +44,6 @@ signature and raises `NotImplementedError` pointing callers at
time-of-peak); the two uint16 fields (probably PVS contributions);
8-byte interval tail (PVS data); mic dB(L) exact conversion constant.
## Verified against Thor's own exports (2026-09-10)
**The series-4 decoder is now per-sample exact.** 1,057,536 / 1,057,536
geophone samples across all 153 genuine Thor waveform files reproduce Thor's
own CSV export exactly; histogram peaks land within 2% on 858/858 files
(median error −0.004%).
### Ground truth — it was there all along
Thor writes `TXT/`, `CSV/`, `XML/` and `PDF/` exports beside every binary:
```
<serial dir>/UM13981_20220207084555.IDFW
<serial dir>/CSV/UM13981_20220207084555.IDFW.csv
```
The **CSV carries a per-sample block** — four columns (Tran, Vert, Long, Mic)
in in/s and psi, after the 2-column report header. That is the series-4
equivalent of Blastware's `_ASCII.TXT` exports, and it gives 1,012 paired
files (152 IDFW + 860 IDFH). Earlier notes in this file and in
`micromate/idf_file.py` asserted "Thor has no ASCII ground truth in the
corpus"; that was wrong, and it is why the decoder sat pinned to a
superseded walker with a scaling constant nobody could check.
Harness: `scratch/verify_thor_against_csv.py`.
### Geo LSB = 0.000310308 in/s per count (NOT 0.0003)
The old 0.0003 was read off the smallest non-zero sample in the exports —
but that is Thor's **4-decimal display rounding of the LSB, not the LSB**.
It read every series-4 geophone sample **3.3% low**. The quantisation
ladder gives it away: counts 1..6 export as 0.0003, 0.0006, 0.0009, 0.0012,
0.0016, 0.0019 — an LSB of exactly 0.0003 would end 0.0015, 0.0018.
Each exported sample constrains the LSB to the window that rounds to its
printed value. Intersecting 991,415 such constraints gives
```
LSB ∈ [0.000310307933, 0.000310308057] width 1.2e-10
```
so `_GEO_LSB_IPS = 0.000310308`, i.e. full scale 10.0 in/s = **32226.05
counts**. Corroboration: an IDFH interval that never recorded keeps its
min/max accumulator at its ±full-scale seed, and that seed is
`(min=+32226, max=-32226)`. ⚠ The tempting closed form `10.0/32226` is
very slightly wrong — it lands 4.5e-10 above the feasible window and loses
78 boundary samples while never winning one. **Series III uses 32000 counts
for the same 10.0 in/s, so the two generations do not share a scale.**
Independently confirmed on 8 production units (UM6047, UM11402, UM11719,
UM12947, UM13981, UM14133, UM20146, UM20147): every unit's median PPV error
against its device-reported peak moved from −3.3% to within ±0.03%. It is a
global constant, not a per-unit calibration.
### IDFH segment header: the counter is a uint16, and it is cumulative
```
[length_be 2B][0a 00 00 00][counter_be 2B][05 3f]
```
`counter` is the **0-based cumulative index of the last interval in the
segment** — 9, 19, 29, ... for the usual 10-intervals-per-segment layout
(`length` = 730).
The validator used to require `counter`'s high byte to be `0x00`. That
silently **capped every histogram at 250 intervals**: once the cumulative
counter passed 255 the high byte went non-zero and every later segment was
rejected. Any run longer than ~4 hours lost its tail — frequently the part
holding the event peak, so the file's PPV read low. **540 of 858 corpus
files were affected**; fixing it moved histogram peaks from 48.3% to 93.8%
within 0.5% of Thor's reported PPV.
### Unwritten interval slots carry a ±full-scale seed
An interval the device reserved but never wrote keeps `min = +32226`,
`max = -32226` on all four channels — `min > max`, impossible for real data.
Decoded naively it yields a 10.0 in/s peak on every channel and, being a
max-over-intervals, poisons the whole file's PPV. Rare but real: exactly 1
of 497,611 corpus intervals, and it inflated that file's Long PPV from
0.0081 to 10.0 in/s. The inversion is all-or-nothing across channels (0
partial cases), so requiring every channel to be inverted is a safe test.
### Record mode `00 00` — raw int16 absolute (MODE_RAW16)
The record chain's mode field at `off+8` takes a fourth value:
| mode | meaning | header |
|---|---|---|
| `02 00` | deltas + two int16 anchors | 14 B |
| `01 00` | absolute, tagged blocks | 10 B |
| `00 03` | raw 12-bit absolute, untagged | 10 B |
| **`00 00`** | **raw int16 BE absolute, untagged** | **10 B** |
A `MODE_RAW16` record with `length = 1032` carries exactly
`(1032 - 8) / 2 = 512` samples and reproduced Thor's export **512/512
exactly** on first test. Thor uses it for segment 0 (the pre-trigger
window) on some events. Before this mode existed the record fell through
the dispatch unhandled, so the channel silently lost its first 512 samples —
which is what produced the "loud events truncate" symptom.
`MODE_ABSOLUTE` is also valid as a **preamble** (the implicit segment-0 Tran
record); its tagged blocks start at `body[3]`, not `body[7]`, because its
header is 10 bytes rather than 14.
### Body offset is not fixed at 0x0f1f — and 0x0f1f is really a record + 7
A "body offset" is `<record start> + 7`, so that `body[0]` is the segment
index and `body[1:3]` is the mode. The canonical `0x0f1f` is simply the
record at `0x0f18`.
Searching for the literal preamble `00 02 00` finds only MODE_DELTA bodies,
and worse, it **matches the `[seg][mode]` bytes inside any record header**,
so the scan could pick a candidate part-way down the chain. That decodes a
plausible-looking but rotation-shifted body which drops each channel's
segment 0 — the real cause of the remaining truncations.
`_find_waveform_body_offset()` now anchors on record headers (the
`<channel_id> 00 00` signature at `+4`, validated with `is_record()`),
takes the **chain head** — a record no other record's length field points at
— and trial-decodes `head + 7`, preferring the candidate where all four
channels come out the same length.
⚠ Do **not** scan for candidate preambles instead: `MODE_RAW16` is
`00 00`, so every run of three zero bytes looks like a body start and each
costs a full trial decode (~0.5 s/file measured, vs 6 ms/file now).
### `40 NN` is not capped at NN=8 (2026-09-11)
`data_block_len()` rejected any `40 NN` int16 block with `NN > 0x08`. The cap
had no evidence behind it — every corpus available when it was written used
only NN ∈ {1, 2, 3, 4, 8}, so it was never exercised. Loud events use much
wider blocks:
| corpus | `40 NN` values | walker stops |
|---|---|---|
| first + 3-channel corpora | 1, 2, 3, 4, 8 | none |
| UM12947 2025-07..09 | 2, 4, 8, **12, 16, 20 … 196** | every value > 8 |
Because `walk_body`/`run` stop at the first unrecognised tag rather than
raising, this surfaced as **silently short channels** — e.g. Tran 1812 /
Vert 2132 / Long 2324 on a file whose export has 2324 for all three. The
real bound is the buffer (and the caller's record end), not a magic constant.
Verified against Thor's exports for UM12947 (2025-07-14 … 2025-09-25, 167
waveforms): length mismatches **22 → 0**, and **1,476,242 / 1,476,249**
samples exact.
⚠ These events are **not** truncated recordings, which was the competing
hypothesis — the exports carry the full sample count.
**The 7 residual samples are Thor's rounding, not ours.** Each differs by
exactly one 4th-decimal tick (e.g. decoded 3.3551 vs export 3.3550).
Intersecting the per-sample rounding constraints over this corpus is
**infeasible** — the binding pair (count 2013 → 0.6247, count 4351 → 1.3501)
contradict by 2.3e-11, i.e. 7e-5 relative. No single linear LSB can
reproduce every printed value, so Thor is not doing plain round-half-up on
`count × LSB`. Do not retune `_GEO_LSB_IPS` to chase these; it is already
pinned to ~1e-11.
### Mic-disabled units are a distinct shape (2026-09-10, second corpus)
Some units run with the microphone disabled — **3 channels, not 4** — and that
changes two structural things. Confirmed on the `9-10-26-csv-req` corpus
(UM11402, UM12947, UM20147): 139/139 waveforms and 877/877 histograms.
**Waveform: the body starts earlier.** A 3-channel unit has a shorter fixed
header and puts its record chain head at **`0x0dba`**, below the old
`_BODY_SCAN_FLOOR` of `0x0E00`. The head was therefore invisible to the scan,
which fell through to the *Vert* segment-0 record and decoded a body shifted
one position around the channel rotation. The signature is unmistakable:
```
Tran 3072 / Vert 2560 / Long 3072 / MicL 0 <- Vert exactly 512 short
```
46 of 139 files in that corpus were affected; all 46 became per-sample exact
once the floor dropped to `0x0C00`. Note the body-offset scoring also had to
stop requiring four channels — `len(lengths) >= 3`, not `== 4`, or `equal` is
permanently False for these events and the pick falls back to raw sample count.
**Histogram: the interval record is 56 bytes, not 72.**
```
interval_size = 16 × n_channels + 8 (72 for 4 channels, 56 for 3)
```
It is **not a constant**, and it cannot be inferred from `length` alone.
Derive the interval count from the segment counter — it is cumulative, so
`n = counter - previous_counter` — and then `stride = (length - 10) / n`.
`n_channels` follows from `(stride - 8) / 16`.
Assuming 72 read 7 intervals out of each 10-interval segment and then walked
off alignment into garbage that decoded as ~10 in/s peaks — inflating those
files' PPV by up to 191,000%. Fixing it moved the second corpus from 56.6% to
**100.0%** of histograms within 2% of Thor's reported PPV, and recovered 4
files that previously decoded no intervals at all.
### What is still open
- ~~23 of 575 production IDFW files~~ — **RESOLVED 2026-09-11.** Production
IDFW is now **575/575** with zero truncations and zero decode failures
(median PPV error −0.0007%). See "`40 NN` is not capped at NN=8" above.
- Mic → psi scale is still the rough `2.14e-6` regression, not derived.
- Per-channel `int16 field4` in the IDFH interval record (possibly
time-of-peak) and the 8-byte tail (PVS data) remain undecoded.
⚠ **Thor's histogram PPV has a display floor of 0.0050 in/s.** In the
production store 6,080 sidecar PPV values are exactly 0.0050 (next most
common value: 275 occurrences), and **41.4% of IDFH sidecars report a
component PPV larger than their own vector sum** — geometrically impossible.
On those quiet files the decoder's ~0.0025 in/s is *more* accurate than the
reference; do not "fix" the decoder to match it.
### Codec breakthroughs (2026-05-28)
- **Body offset is a fixed `0x0f1f`** across 151/154 corpus IDFW
-9
View File
@@ -11,7 +11,6 @@
| Date | Section | Change |
|---|---|---|
| 2026-10-17 | §7.6.1 | 🔶 **OPEN — the 6-byte "stable anchor" may be two settings at their defaults, not a constant.** Series IV's `0x1A` has the same field order as the S3 compliance block, and a keypad diff pass on a Micromate (UM20147) measured the bytes in the anchor's position: `[f32 BE pre-trigger, negative seconds][record stop mode, 00 00 = Fixed]`. `be 80 00 00` is exactly −0.25 s. If S3 matches — **inferred, not measured on S3** — then any S3 unit set to Record Stop Mode = Auto (a basic Blastware Compliance Setup option) or a non-default pre-trigger loses the anchor, and `client.py` silently decodes no recording mode / sample rate / interval / record time and skips them on write. No S3 capture has ever been taken in Auto stop mode (see the 2026-03-09 Auto Window rows), which would explain why the anchor never broke. To settle: one BW capture with Record Stop Mode = Auto. See `docs/micromate_protocol_reference.md` → *The `0x1A` field map from a keypad pass*. |
| 2026-08-26 | S7.6.2, S15 | **MULTI-INTERVAL HISTOGRAM BLOCKS - sub-minute intervals pack several per block.** The device always writes one minute of data per block, so a shorter histogram interval means more intervals packed into a longer block: 1 min -> 1 (the standard 32-byte block), 15 s -> 4 (stride 92), 2 s -> 30 (stride 612), with `stride = 12 + n * 20`. Each 20-byte record holds 8 x uint16 **little**-endian values (peak/half-period per channel) plus a 2-word tail whose first word is `0000` on every real interval. The standard block is big-endian - the variant is not. This recovers **415 files** (216 on BE18193 at 2 s, 199 on BE9440 at 15 s) that previously decoded to nothing, and before that were being accepted by the WAVEFORM codec and returning garbage up to 400x the device-reported PPV. |
| 2026-08-25 (3) | S7.6.1, S15 | **THE WAVEFORM BODY IS A RECORD CHAIN, NOT A TAG STREAM — supersedes the segment-header model entirely.** Records are self-delimiting: `off+2` is a uint16 BE length and `next = off + 2 + len`; the chain ends on a record whose chan_id is `0x06`. `off+8` holds a 3-valued mode enum - `02 00` (14-byte header, anchors, cumulative deltas), `01 00` (10-byte, no anchors, ABSOLUTE values), `00 03` (10-byte, no tags at all, raw 12-bit absolute). **`40 NN` is an ordinary int16 BE data block of length 2*NN+2**, never a header; reading it as a 2*NN+16 header is what made walks drift, and the 'variable prefix' of 0/2/4/6/8 bytes reported earlier the same day was walker drift, exactly `4 - (old_stop - true_record_start)`. Verified: chain terminates on `06` in 1387/1388 files; all four channels equal length in **1388/1388** (was 156/1388); ASCII sample-count exact 72/75 -> **75/75**, fully exact 70/75 -> **73/75**; device PPV on a live decode **1306/1306** waveform (mean abs ratio error 0.00000) and **4458/4459** histogram. Also eliminated the walker-over-read class: 24 of those files were histograms the waveform codec was wrongly accepting. The superseded model is retained as `decode_waveform_legacy` because `micromate/idf_file.py` pins it for Thor IDFW body-offset search. |
| 2026-08-25 (2) | S7.6.2, S15 | **HISTOGRAM BLOCK IS BIG-ENDIAN + terminal block tail.** The 32-byte histogram block's per-channel fields are uint16 **big-endian** (`T_peak` [5:7], `T_halfperiod` [7:9], `V_peak` [9:11], `V_halfperiod` [11:13], `L_peak` [13:15], `L_halfperiod` [15:17], `M_peak` [17:19], `M_halfperiod` [19:21]); only `block_ctr` [2:4] is little-endian. The marker is `block[4]` alone - the previous uint16 LE marker test at [4:6] forced `block[5] == 0` and thereby capped every geo peak at 255 counts (1.275 in/s), silently clipping larger peaks. The byte previously documented as a per-channel "annotation" is the high byte of the big-endian half-period, which is why it was non-zero exactly on sub-Hz intervals. Separately, the **final block of each stream carries tail `9c 06 00 42`** rather than `1e 0a 00 00` and holds arbitrary bytes at [21:23]; rejecting it dropped the last interval of nearly every histogram. Verified against 1211 production histograms paired with their Blastware ASCII exports: 1211/1211 decode exactly, plus 842,442 per-interval frequency comparisons with zero mismatches (previously 1 of 1196 files fully correct). |
@@ -703,14 +702,6 @@ the anchor).
> reconfigured (e.g. 15 min = `\x03\x84`). Only the 6-byte suffix is constant.
> Code in `client.py` uses `buf.find(b'\xbe\x80\x00\x00\x00\x00', 0, 150)`.
> 🔶 **2026-10-17 — the 6-byte suffix may not be constant either (INFERRED from Series IV).**
> On a Micromate the same position holds `[pre-trigger f32 BE, negative seconds][record stop mode]`,
> measured setting by setting: `be 80 00 00` = −0.25 s, and `00 00` = Fixed (Auto reads `00 01`).
> Every S3 unit this anchor was confirmed on would have been at those defaults. If S3 shares the layout,
> a unit in **Record Stop Mode = Auto** returns `be 80 00 00 00 01`, `find()` returns −1, and the four
> anchor-relative fields silently go undecoded. **Not yet measured on S3** — one BW capture in Auto
> mode settles it. Until then, treat a missing anchor as this, not as DLE jitter.
> ✅ **2026-04-02 — CORRECTED:** Search range was `cfg[40:100]`. With the
> compliance-config orphaned-send bug fixed (§7.6.2), the 44-byte accidental
> header padding is gone and the anchor now appears at `cfg[11]`. Search range
-408
View File
@@ -1,408 +0,0 @@
# Spec — a live client for Series IV (Micromate)
Drafted 2026-09-26, ahead of implementation. The protocol work is finished; this
is the plan for turning `docs/micromate_protocol_reference.md` into code SFM can
run.
**Read that document first.** Everything here assumes it, and every constant
below is sourced from it rather than restated with justification.
---
## Goal and scope
`micromate/` is codec-only today — `idf_file.py`, `models.py`, the report
writers. There is no way to talk to a unit. This adds the live half, mirroring
`minimateplus/`.
**In scope, first pass:**
- connect over TCP (a field modem) or serial/USB (a bench unit)
- identify a unit, read its state, clock, memory and setups
- walk the event chain and download events
- return `Event` objects the existing codec already understands
**Explicitly out of scope, first pass:**
- ⚠ **Any write.** Setups, schedules, call-home config, monitoring start/stop,
and per-event delete are all mapped, and none of them will be implemented
here. **No command has ever been originated against a unit by this project**
— every write observed was performed by THOR while we recorded. Keeping that
true through the read client is deliberate: it means the first thing we ever
send to a customer's instrument is a decision someone made on purpose, not a
side effect of a client that happened to grow a method.
- the inbound call-home session — still the one protocol unknown
---
## Layout
```
micromate/
framing.py NEW frame building, response parsing, checksum
protocol.py NEW one method per wire command, returns raw payloads
client.py NEW high-level API, returns models
idf_file.py (existing — decodes what 0x5A returns, unchanged)
models.py (existing — extend, do not fork)
```
**Transport is reused, not rewritten.** `minimateplus/transport.py` is
byte-level and protocol-agnostic — `BaseTransport`, `SerialTransport`,
`TcpTransport`, plus `read_until_idle()` which already handles the RV50/RV55
habit of emitting `\r\nRING\r\n\r\nCONNECT\r\n` to a caller. Import it.
⚠ Do **not** import `minimateplus.framing`. The two framings differ in ways
that look small and are not, and a shared module would accumulate `if series ==`
branches until neither case is readable.
---
## `micromate/framing.py` — ✅ BUILT 2026-09-27
Implemented, with `tests/test_micromate_framing.py` (31 tests, all passing).
**Two things in this section as originally drafted were wrong**, and both were
caught by measuring against the captures before writing code rather than after.
They are left in place below, struck through, because both are the kind of
mistake that would be made again.
### Requests
~~Series IV accepts Series III request frames unmodified. The simplest correct
implementation re-exports the builder rather than duplicating it:~~
```python
from minimateplus.framing import build_bw_frame # ✗ WRONG — 161/218
```
⚠ **`build_bw_frame` reproduces only 161 of Thor's 218 captured read frames.**
The payload layout is identical; the stuffing is not. A Micromate escapes
**four** byte values — `0x02`, `0x03`, `0x04`, `0x10` — where Series III
escapes one. The frames this breaks are **every `SUB 0x5A` download**
(`offset = 0x0400` → a literal `0x04` in `offset_hi`) and the scheduler enable.
An unescaped `0x03`/`0x04` terminates the frame early, so the unit just does not
answer.
`build_request()` with the correct escape set reproduces **218/218**.
✅ **Settled: `0x10` inside params needs no special handling.** The planned
`NotImplementedError` guard is unnecessary — Thor sends
`params = 00 00 10 00 …` on `SUB 0x5A` in five captured frames and the wire
carries an ordinary doubled `10 10`. One rule covers the whole payload.
### Responses — where Series III's parser cannot follow
| | Series III | Micromate |
|---|---|---|
| frame start | `DLE STX` | **bare `STX`** |
| `payload[1]` | `0x10` | `0xC5` (Blastware fw) / `0x03` (Thor fw) |
| destuffing | `DLE+ETX` kept as literal inner-frame data | **`10 XX` → `XX`, uniformly** |
The first row is why `S3FrameParser` returns nothing at all on Series IV traffic:
it scans for `DLE+STX`, which never appears.
The third is a genuine **simplification** — no inner-frame carve-out. Validated
by checksum across every capture in `bridges/captures/9-24-26 - micromate2/`:
four candidate destuffing rules were tried, and only this one makes all frames
validate.
### Checksum
```python
def checksum(payload: bytes) -> int:
return sum(payload) & 0xFF # payload already de-stuffed
```
~~The DLE-aware variant, same as Series III's `5A` and write frames.~~
⚠ **Plain SUM8, not the DLE-aware variant** — 251/251 both directions. The
DLE-aware form is the right answer paired with *Series III* de-stuffing, which
leaves an escaped byte in the payload as two bytes. De-stuffing `10 XX → XX`
already removes the `0x10`, so excluding it again subtracts the correction
twice, and the result disagrees with the wire on **55 of 251** captured
responses — every frame holding a literal `0x10`.
`scratch/mm_frame_parse.py` shipped with exactly that pairing. It looked clean
only because it accepts a frame matching *either* rule, so it labelled those 55
`SUM8` and never flagged one bad. "Zero bad checksums" was true and carried no
information. Fixed there too.
### ⚠ The SUB byte can be escaped
When a SUB's value is `0x02`, `0x03`, `0x04` or `0x10` it arrives as `10 XX`.
Reading it positionally without destuffing reports `0x10`. This bit once
already — `SUB 0x02` was logged as `SUB_10` for an afternoon. Destuff first,
then index.
### Response shape
```python
@dataclass
class MicromateFrame:
sub: int # response SUB; request = 0xFF - sub
flags: int # 0xC5 Blastware line, 0x03 Thor line
page_hi: int
page_lo: int
data: bytes # payload[5:], checksum stripped
checksum_valid: bool
@property
def request_sub(self) -> int: # 0xFF - sub
@property
def page_key(self) -> int: # uint16 BE at payload[3:5]
@property
def firmware_line(self) -> str: # "blastware" | "thor" | "unknown"
@property
def probe_length(self) -> int | None: # uint16 BE at data[3:5] (= payload[8:10])
```
⚠ **`probe_length` is a uint16 BE.** Read as a single byte it under-reads
`SUB 0x1A` by 47x — 44 against a true 2092. This is the single most expensive
mistake available in this protocol and it has already been made once.
Renamed from `declared_length`, because it is **only meaningful in the reply to
an `offset = 0` probe** — and Thor never probes. Across all 251 captured
responses the field reads 0 or a page count, never a length, precisely because
that session is single-step reads throughout. `page_key` is the field that
carries meaning there. The only genuine probe reply we hold is the POLL one
preserved in `scratch/fake_unit.py`.
`MicromateFrameParser` mirrors `S3FrameParser`: `feed(bytes) -> list[frame]`,
accumulates in `.frames`, `reset()`, and keeps the `bytes_fed` counter (it is
what distinguishes "no bytes at all" from "bytes but no complete frame" on a
timeout, and that distinction earned its keep during the Series III work).
---
## `micromate/protocol.py` — ✅ BUILT 2026-09-27
Implemented, with `tests/test_micromate_protocol.py` (35 tests). Reads only;
nothing here writes, erases or changes monitoring state.
The tests replay Thor's captured responses through a scripted transport and
assert **the bytes we emit are the bytes Thor emits** — including a full replay
of the six-event download session, all 56 `0x5A` frames byte-for-byte. That is
a stronger guarantee than "our parser understands the device": a passing test
means a real unit has already answered exactly that frame.
One method per command, returning raw payload bytes. No interpretation — that
belongs in `client.py`.
**Reads use `offset = 0xFFFF`** and return the whole block in one response;
Series III's two-step probe/data dance is unnecessary. `POLL` is the exception,
taking its data length. Per-command offsets, all observed:
| command | SUB | rsp | offset | returns |
|---|---|---|---|---|
| poll | `0x5B` | `0xA4` | `0x0030` | device string, model |
| serial | `0x15` | `0xEA` | `0x000A` | `UM12947` |
| device info | `0x01` | `0xFE` | `0xFFFF` | firmware, calibration |
| state | `0x49` | `0xB6` | `0xFFFF` | `data[11]`: non-zero = monitoring |
| monitor status | `0x1C` | `0xE3` | `0xFFFF` | flag, **device clock**, battery, memory |
| storage range | `0x06` | `0xF9` | `0xFFFF` | event storage extent |
| active setup name | `0x41` | `0xBE` | `0xFFFF` | `TEST1.mmb` |
| first setup | `0x3F` | `0xC0` | `0xFFFF` | setup-list walk head |
| next setup | `0x40` | `0xBF` | `0xFFFF` | …until an empty name |
| compliance config | `0x1A` | `0xE5` | `0xFFFF` | ~2103 B setup block |
| call-home config | `0x2C` | `0xD3` | `0xFFFF` | 137 B |
| arm event | `0x93` | `0x6C` | — | before every event |
| first event | `0x1E` | `0xE1` | `0xFFFF` | key + size |
| next event | `0x1F` | `0xE0` | `0xFFFF` | key + size |
| event record | `0x0C` | `0xF3` | `0xFFFF` | 221 B — project, location, peaks |
| ~~event header~~ **monitor log** | `0x0A` | `0xF5` | `0xFFFF` | ⚠ 297 B, a **walk** — see below |
| bulk download | `0x5A` | `0xA5` | computed | **the `.IDFW` verbatim**, 1024 B at a time |
⚠ **Corrected 2026-09-27, from Thor's frames.** Three rows of the table above
were wrong or incomplete, and the last one is a different command than labelled:
- **`0x0A` is the monitor-log walk**, not a keyed "30 B list record" read. The
*same request repeated* returns successive 297-byte records — serial, mode,
thresholds — until an 11-byte ack ends the list. The device holds the cursor;
nothing in the request selects a record. Series III reaches this data through
a record-type discriminator on its event chain; here it has its own cursor and
the event chain never sees it.
- **`0x1E`/`0x1F` carry token `0xFE` at `params[7]`.** The reference documents
all-zero params (our own probing, which also worked). Thor's form is the one
with mileage.
- **`0x01` has no Thor frame behind it** — it is never read in any captured
session. Its `0xFFFF` comes from our probes.
And one useful negative: **no `SESSION_RESET` (`41 03`)**. Series III needs that
2-byte signal or a monitoring unit will not answer `POLL` over TCP. Thor never
sends it — zero occurrences across 8 sessions, including 40 frames exchanged
with a unit that *was* monitoring.
⚠ **`SUB 0x1C` is 4 bytes longer on the Thor firmware line** (`0x30` vs `0x2C`).
Parse **forward** from `declared_length`, never backward from the end — Series
III reads battery and memory from the end of that block, and doing so on a BD
unit yields a battery voltage of **577.92 V**.
⚠ **Test the monitoring flag for non-zero**, never against a constant. It has
read both `0x0E` and `0x0C` while monitoring.
### `0x5A` — a bounded chunk loop, and much simpler than Series III
⚠ **Corrected 2026-09-27.** This section said "no chunk loop — one request
returns the whole event", with `offset_word = 0x1000 + 2 * ceil(size / 512)`.
That describes our own 2026-09-23 probes, which set `offset_hi = 0x10`. **Thor
chunks**, and Thor's form is the one verified from bytes on disk:
```python
n = ceil(size / 1024) # size from the chain walk
for i in range(n):
offset = min(1024, size - 1024 * i) # a BYTE COUNT
params = key4 + bytes(6) if i == 0 else bytes(2) + pack(">H", 1024*i) + bytes(6)
file_bytes += response.data[11:] # response data is exactly offset + 11
```
Verified on all six bench events (4,076 → 13,424 B): `sum(offsets) == size`
exactly, with the predicted chunk count and final offset every time.
Still no arming ritual for `0x5A` itself, no `STRT` end-offset parsing and no
`TERM` frame — the simplification the original claim celebrated is real, it just
is not single-shot. (`SUB 0x93` arms the *chain walk*, before `1E`/`1F`, not
the download.)
The concatenated payload **is** the `.IDFW` file, byte for byte — so it feeds
`micromate.idf_file.read_idf_file()` and `/db/import/idf_file` unchanged.
⚠ Do not port the Series III `5A` walk. Its address arithmetic caused a 5x
over-read and a `> 64 KB` page-boundary bug that is *still open* on the Series
III side. None of that applies here: the chunk index is a byte offset into the
file, bounded by a size the device told us, and it cannot run past the event.
⚠ **`assert sum(len(chunk) - 11 for chunk in chunks) == size`.** A silently
short event is the failure mode this project has been bitten by repeatedly on
the Series III side, and here the check is free because the size is known up
front.
---
## `micromate/client.py` — ✅ BUILT (read half) 2026-09-27
`connect()`, `get_state()`, `get_active_setup()`, `list_setups()` plus
`MicromateDeviceInfo` / `MicromateState` in `models.py`. 26 tests, every
response constant a real captured data section.
⚠ **`connect()` is deliberately narrower than this spec asked for.** The spec
said to mirror Thor's `POLL → SERIAL → 0x49 → POLL` "because it is known-good".
Measurement showed the four-command form is Thor's *connection check*, present
in 3 of 8 sessions, and its fourth frame repeats its first — so `connect()`
sends the three reads that gather something. `0x01` is not read at all: Thor
never reads it, its layout is unmapped, and `firmware_line` comes free from any
response's flags byte.
Event-chain methods (`list_events`, `download_event`, `get_event`) are step 4
and not yet written; `MicromateProtocol.read_event_file()` already does the
download.
```python
class MicromateClient:
def __init__(self, transport: BaseTransport): ...
def open(self) / close(self) / is_open(self)
# identity and state
def connect(self) -> DeviceInfo # poll → serial → device info → state
def get_state(self) -> UnitState # monitoring?, clock, battery, memory
def get_active_setup(self) -> str
def list_setups(self) -> list[str] # 0x3F → 0x40… until empty
# events
def list_events(self) -> list[EventRef] # 0x93 → 0x1E → 0x1F… (key + size)
def download_event(self, ref) -> bytes # raw .IDFW/.IDFH
def get_event(self, ref) -> Event # download + decode via idf_file
```
`connect()` should mirror THOR's preamble (`POLL → SERIAL → 0x49 → POLL`) —
⚠ but note the reference records that **whether the unit requires it is
untested**. Do it because it is known-good, not because it is known-necessary,
and say so in the docstring.
`list_events()` returns the key *and* the size, because `download_event()` needs
the size to compute its offset word.
---
## Tests
**Offline, from captured bytes — no hardware.** This is the part worth doing
first, because it can be fully verified tonight's-captures-style before any unit
is involved.
```
tests/test_micromate_framing.py
```
⚠ `bridges/captures/` and `tests/fixtures/` are both gitignored, so tests must
not depend on files being present. **Embed the frames as hex constants** — they
are 19–138 bytes each. ✅ Done; what actually landed:
| case | source | why |
|---|---|---|
| POLL probe reply, 19 B | captured (via `fake_unit.py`) | shortest valid frame; the only real probe reply we hold |
| `0x5A` chunk, 138 B | captured | holds literal `0x10` **and** literal `0x41` — the checksum case, and proves ACK is not escaped |
| `0x49` state reply, 25 B | captured | a literal `0x02`, escaped |
| `0x48` file reply, 24 B | captured | escaped `0x04` in `data[0]` — one byte late without destuffing |
| 8 Thor request frames | captured | byte-for-byte against `build_request()`, incl. both `0x5A` forms and the scheduler enable |
| `probe_length = 0x082C` | **synthesised** | no probe reply for `0x1A` exists on disk — the 9-24-26 session never probes |
| Thor-line reply, `flags = 0x03` | **synthesised** | no 11.0BD capture is in the repo; built by flipping one byte of the real POLL reply |
| escaped checksum byte | **synthesised** | the shortest real one is 1,070 B, too long to embed for one assertion |
| truncated / corrupt / split-across-feeds | derived | parser must return nothing, flag rather than swallow, and survive any split point |
⚠ Synthesised frames are marked `SYNTH_`-style in the test and each says what it
stands in for and why no capture was available. Do not let that set grow
quietly: the `flags = 0x03` case in particular is the **only** coverage of half
the fleet, and it deserves a real 11.0BD capture the next time UM20147 is on a
bench.
Two corpus-backed tests run when the captures happen to be on the box and skip
cleanly otherwise: **251 response frames parse with zero bad checksums**, and
**`build_request()` reproduces 218/218 read frames**. The second is the test
that would have caught the escape-set error, so it is worth the skip marker.
⚠ Do **not** assert against `scratch/mm_frame_parse.py`'s output as the original
plan proposed. That script accepts either checksum rule and is wrong about
which one is right — using it as an oracle would have pinned the bug.
**Live, second:** against the bench unit on mint-mac via `mm_link.py`.
`connect()`, `list_setups()` (should return the 23 known names), `list_events()`,
then `download_event()` and assert the bytes decode and match a
`/db/import/idf_file` ingest of the same event.
---
## Order of work
1. ✅ `framing.py` + its tests — **done 2026-09-27**, 31 tests, offline
2. ✅ `protocol.py` + its tests — **done 2026-09-27**, 35 tests, offline
3. ✅ `client.py` + its tests — **done 2026-09-27**, 26 tests, offline
4. the event chain and `download_event()`
5. decode end-to-end and compare against a store event
Steps 1–2 need no hardware at all.
**Worth carrying forward.** Both steps began by measuring against the captures
rather than trusting this document, and both found errors in it — three in the
framing rules (the escape set, 26% of frames; the checksum, 22%; the `0x5A`
chunk model) and three more in the command table (`0x0A`'s meaning, the
`1E`/`1F` token, `0x01`'s provenance). All six fail quietly. The captures are on
disk and a measure-then-write loop costs about two minutes per rule, so keep
doing it for `client.py`'s field offsets — and treat this spec as a plan, not a
source.
---
## Open questions to settle while implementing
- ~~**Request param stuffing**~~ — ✅ settled 2026-09-27; no special handling.
- **Is the single-request `0x5A` form real?** Our 2026-09-23 probes set
`offset_hi = 0x10` and appeared to get a whole 11 KB event back, where Thor
chunks at 1024 B. Plausibly a distinct streaming mode that returns several
frames. One bench test settles it; implement Thor's form regardless.
- **Is THOR's preamble required?** Try one command cold and find out; it is a
two-minute test with the bench unit and it removes a ritual if unnecessary.
- **`Event` model fit** — Series IV carries fields Series III lacks (setup file
name, `LMic`/`SMic` channels). Extend `micromate/models.py`; do not fork the
shared `Event`.
- **Which `0x0C` fields to trust.** The peak float there runs 2–5% above
`max(T,V,L)` and is **not** the vector sum; its offset was inferred, not
established. The reference marks it do-not-rely-on — prefer decoded samples.
File diff suppressed because it is too large. Load diff
-135
View File
@@ -1,135 +0,0 @@
# USBM RI8507 / OSMRE Blasting Compliance Curve — Reference
Reference for the **velocity-vs-frequency blasting compliance chart** Blastware
draws on its Event Report ("USBM RI8507 And OSMRE"), and how seismo-relay
reproduces it. Implemented in [`sfm/compliance.py`](../sfm/compliance.py); the
spectral (FFT) side lives in [`waveform_fft.py`](../waveform_fft.py).
Reverse-engineered 2026-09-14 against 7 BE12844 (MiniMate Plus) events, each
with a Blastware Event Report + FFT Report as ground truth. Curve values from
USBM RI8507 Appendix B and 30 CFR 816.67.
---
## What it is
Two closely-related sources for the same limit curve:
- **USBM RI8507** — Bureau of Mines *Report of Investigations 8507* (Siskind
et al., 1980), *"Structure Response and Damage Produced by Ground Vibration
From Surface Mine Blasting."* The curve is **Figure B-1**, Appendix B
("Alternative Blasting Level Criteria"), p.73–74.
- **OSMRE / OSM** — the Office of Surface Mining Reclamation and Enforcement
codified it as **30 CFR 816.67, Figure 1**. "CFR" = the U.S. Code of Federal
Regulations. Same curve, regulatory force.
The chart plots each geophone channel's significant vibration cycles as
`(frequency, peak velocity)` points against this limit. A point **below** the
line passes; **above** fails.
---
## The limit curve
A structure has a resonance band (~4–12 Hz for whole structures) where it is
most vulnerable, so the safe velocity is **lower** at those frequencies and
**higher** away from them. The curve captures this by alternating two kinds of
bound:
- **Constant-velocity** segments — a flat horizontal line at a fixed PPV.
- **Constant-displacement** segments — a fixed peak *displacement* `d`. For
simple harmonic motion, peak velocity `v = 2πf·d`, so on a velocity-vs-
frequency **log-log** plot this is a straight line of slope +1 (velocity rises
with frequency). This is why the low- and high-frequency bounds are sloped.
### Two lines — structure type
RI8507 gives two lines for two interior-wall constructions (Table 13, p.67):
| line | construction | plateau PPV |
|---|---|---|
| **Drywall** (solid) | modern gypsum wallboard | **0.75 in/s** |
| **Plaster** (dashed) | older plaster on wood lath | **0.50 in/s** |
Plaster-on-lath is more damage-prone, hence the lower limit. You apply **one**
line depending on the monitored structure.
### The four segments (Figure B-1, p.74)
Going low → high frequency, each line is:
1. **Ultimate low-frequency bound** — constant displacement **0.030 in**
(`v = 2πf·0.030`). Only relevant below ~4 Hz.
2. **Plateau** — constant velocity **0.75** (Drywall) / **0.50** (plaster) in/s.
3. **Rising diagonal** — constant displacement **0.008 in** (`v = 2πf·0.008`),
climbing from the plateau up to the high-frequency cap.
4. **High-frequency cap** — constant velocity **2.0 in/s** above ~40 Hz.
The segments are drawn **continuous**: each bound is used over the frequency
range where it is the binding (lowest) limit, and consecutive bounds meet where
they are equal — so there are no vertical steps. Transition frequencies come
straight from the values (`f = V / (2π·d)`):
| transition | formula | Drywall | Plaster |
|---|---|---|---|
| 0.030 in → plateau | `V_mid / (2π·0.030)` | 3.98 Hz | 2.65 Hz |
| plateau → 0.008 in | `V_mid / (2π·0.008)` | 14.92 Hz | 9.95 Hz |
| 0.008 in → 2.0 in/s | `2.0 / (2π·0.008)` | 39.79 Hz | 39.79 Hz |
Because both lines share the same **0.008 in** rising diagonal, above ~15 Hz
they lie on the *same* line (both reach 2.0 in/s at ~40 Hz) — RI8507's literal
construction merges them there. Blastware renders the dashed line as a separate
parallel diagonal, but that is cosmetic: above ~15 Hz both structure types carry
the identical limit, so compliance is unaffected.
> ⚠ RI8507's *Table 13* is a simpler two-range criterion with a **sharp
> discontinuity at 40 Hz** (flat plateau, then a jump to 2.0). Figure B-1 is the
> **smoothed** version that adds the 0.008 in transition — that is the one drawn
> on reports and implemented here.
---
## The compliance scatter (the points)
The cloud is **not** the FFT spectrum. It is a per-cycle, time-domain measure by
the **zero-crossing method** (`channel_compliance_points`):
- Split the channel's waveform at its zero crossings.
- Each half-cycle contributes one point: **frequency** `= 1 / (2 · half-period)`
(from the samples between the two crossings), **velocity** `= peak |amplitude|`
in that half-cycle.
This yields ~90–110 points per channel, and — by construction — each channel's
**highest** point equals that channel's PPV. Verified against Blastware: the
cloud shape, density, and ceiling all match.
### Why not the FFT?
A broadband blast spreads its energy across many FFT bins, so no single bin
reaches the time-domain peak — the FFT amplitudes come out ~10× below the
compliance-chart velocities. The compliance chart is a *per-cycle peak* view;
the **FFT** is a separate analysis (Blastware's *FFT Report*), reproduced by
[`waveform_fft.py`](../waveform_fft.py) and used for the dominant-frequency
readout and the #10 FFT view — not for this scatter.
---
## Implementation
- `sfm/compliance.py`
- `limit_at(freq, curve)` — the limit PPV at a frequency (`curve` = `"Drywall"`
or `"Plaster"`); curves are data in `_CURVES`, so more standards can be added.
- `channel_compliance_points(samples, sps)` — the zero-crossing scatter.
- `draw_compliance_chart(ax, channels, sps)` — matplotlib rendering (both
limit lines + per-channel scatter, Blastware's tick scales and channel
markers: Tran `+` red, Vert `×` green, Long `o` blue).
- Tests: `tests/test_compliance.py`.
---
## Sources
- USBM **RI8507** (Siskind, Stagg, Kopp, Dowding, 1980), Appendix B / Figure B-1,
p.73–74; Table 13, p.67. (`ref-stuff/usbm-ri8507-ground_vibration.pdf`.)
- **30 CFR 816.67**, "Use of explosives: Control of adverse effects," Figure 1 —
<https://www.ecfr.gov/current/title-30/chapter-VII/subchapter-K/part-816/section-816.67>
+3 -327
View File
@@ -1,7 +1,6 @@
# Runbook — Recovering a wedged unit stuck in a call-home loop
**Incidents:** BE9558H at `166.246.130.1:9034`, 2026-05-17 (Method B) ·
BE12599 at `166.246.64.226:9034`, 2026-09-16 (Method A).
**Original incident:** BE9558H at `166.246.130.1:9034`, recovered 2026-05-17.
A field unit with a stuck-triggered geophone (or any hardware fault causing
constant event triggering) will record events back-to-back, and if Auto Call
@@ -15,33 +14,6 @@ This runbook describes how to break the loop and recover control.
---
## ⚠ Two cures for one disease — intercept first
Both incidents below are the **same failure**: a geophone offset crosses the
trigger level, the unit records back-to-back, ACH set to "after event
recorded" dials continuously, and the unit becomes unreachable because its
modem is in client mode almost all of the time.
There are two ways to get a Stop Monitoring command into it.
| | **A — intercept the call** (preferred) | **B — catch it between calls** (original) |
|---|---|---|
| Idea | Be the server it dials. Point the modem's Destination at our own ACH server and answer it. | Clear the Destination so it stops dialing, then race a Stop into the gap. |
| Needs inbound? | **No — the unit calls us** | Yes: working inbound TCP to the modem |
| Determinism | Deterministic — it dials every ~75 s, we only have to be listening | A race. BE9558H took ~7 h of attempts before one landed. |
| Tool | `bridges/ach_server.py --stop-monitoring` | `scripts/slow_drip.sh` |
| Proven on | BE12599, 2026-09-16 | BE9558H, 2026-05-17 |
**Method A is the standard procedure now.** The unit won't answer us because
it is on the phone — so stop dialing it and be the one it calls. It rings,
we pick up, take its data, and tell it to stop calling here.
Method B is kept because it is proven, and because A needs a listener the
modem can actually reach (public IP + forwarded port). When you have that,
don't race it — intercept it.
---
## Symptoms
- Terra-View / SFM `/device/info` either hangs or fails on `count_events()`.
@@ -59,85 +31,9 @@ If you see *all* of these, the unit is in this exact failure mode.
---
## Method A (preferred) — intercept the call
## Quick reference — how to recover
You need **ACEmanager access** and a host the modem can dial: public IP with
the listener's port forwarded to it.
### A1 — start the listener BEFORE touching the modem
```bash
cd /home/serversdown/seismo-relay
tmux new -s rescue
.venv/bin/python -u bridges/ach_server.py --port 12345 \
-o bridges/captures/<unit>-diag --stop-monitoring -v
```
⚠ **Listener first, always.** A Destination pointed at a dead port is the
worst state available — the device still dials, the modem still flips to
client mode, inbound stays blocked, and nothing gets delivered.
Do **not** add `--events-only` (it silently breaks dedup — see gotchas), and
do **not** add `--disable-ach` yet (see A4).
### A2 — point the modem at it
ACEmanager → **Serial → Port Configuration**:
| Field | Set to |
|---|---|
| **Destination Address** | the listener's public IP |
| **Destination Port** | the listener's port (e.g. `12345`) |
Apply. The modem auto-dials its Destination whenever serial data arrives
while the serial port is closed — so the unit's own retry cycle now lands on
you instead of nowhere.
### A3 — answer, and stop the bleeding
Within ~75 s you should see a call-in. `--stop-monitoring` fires SUB 0x97 at
step 1.5 — after the handshake, **before** the event walk — so the recording
halts at the earliest possible moment in the session. Confirm via
`rescue.json` in the session directory:
```json
{"peer": "166.246.64.226:60921", "stop_monitoring": "ok"}
```
That is the bleeding stopped. Everything after this is cleanup.
### A4 — drain the backlog, THEN disable ACH
⚠ **Order matters, and it is counter-intuitive.** Stopping monitoring also
removes your call-in trigger: ACH fires on "after event recorded", so with
recording stopped the unit has no reason to dial again. The backlog sitting
in its memory does **not** re-arm it.
So if the stored events are worth keeping — and on a fault unit they usually
are, they're the evidence — drain them across however many call-ins it takes
*before* you silence it. Only then add `--disable-ach` (or use
`scripts/rescue_device.sh <host> <port> --no-erase`).
If the unit has gone quiet and you still need it, cycling the modem produces
a call-in, and a unit with a scheduled daily call will dial at its configured
time regardless.
### A5 — restore the Destination, and confirm you did
Put `Destination Address` back to `0.0.0.0` (or the office Instantel ACH
server) once you are finished, and only stop the listener after that is done.
### A6 — do NOT re-enable ACH until the hardware fault is repaired
Otherwise the loop restarts the moment monitoring resumes and you run this
runbook again.
---
## Method B (fallback) — catch it between calls
The original 2026-05 procedure. Use when you cannot stand up a listener the
modem can reach. You need **ACEmanager access** to the unit's modem.
You need **ACEmanager access** to the unit's modem.
### Step 1: stop the modem's mode-flipping
@@ -357,223 +253,3 @@ service).
Total time from "i was wondering if its possible to" first attempt to
recovery: ~7 hours of intermittent debugging across one evening.
---
# Second incident — BE12599, 2026-09-16/17
**Unit:** BE12599 at `166.246.64.226:9034`, RV50, job *I-80 North Fork Bridge
— Abut 1 West* (Fay Company). Same job as BE9558H, which is a coincidence.
**Fault:** the connector fault documented in `docs/offset_investigation.md`
§8e progressed until the Tran pedestal reached **0.400 in/s** — its trigger
level. Constant triggering → constant recording → ACH "after event recorded"
→ continuous dialing. Same disease as BE9558H.
**Same disease, inverted cure.** Method B's Step 1 *did* work — clearing the
Destination stopped the dial-outs, confirmed in the ALEOS log. It was Step 2
that didn't land, and rather than keep racing we turned the rescue around:
gave the unit a different server to call, and answered it.
Total time ≈ 5 h, of which ~90 min went to two red herrings documented below.
Much of the rest was rediscovering the May procedure, which is why the
"two cures" table now sits at the top of this file.
---
## Turn on ALEOS_SERIAL debug FIRST
This is the single highest-value diagnostic and it should be step zero on any
future incident. ACEmanager → **Admin → Log → ALEOS_SERIAL log level →
DEBUG**, then view the serial log.
It is the only thing that tells you what the *device* is actually saying.
Everything before we did this was guesswork.
## What the log showed — the unit is on the phone
Every ~75 seconds, verbatim:
```
ALEOS_SERIAL_HIF: 29 byte(s) in buffer: 'ATQ1^MATE0^MATS0=2^M^MRADIO RING^M'
ALEOS_SERIAL_HMC: TCP recvhost fd 65535 len 29 state TCPMode::kClosed
ALEOS_SERIAL_HMC: tcpmode trying to send to invalid socket
ALEOS_SERIAL_HMC: Connect to IP: 0.0.0.0 Port 0
ALEOS_SERIAL_HMC: Initialize Auto answer on port 9034
ALEOS_SERIAL_HMC: Cannot connect to 0.0.0.0
```
Read that carefully:
- `ATQ1` (quiet) / `ATE0` (echo off) / `ATS0=2` (auto-answer after 2 rings).
**There is no `ATD`.** The device is not dialing — it is trying to
*configure* its modem.
- The modem's serial port is in TCP data mode, so it never interprets these
as AT commands. It treats them as payload and tries to ship them to a TCP
socket that does not exist.
- The device therefore never receives `OK`, never progresses, and **retries
the identical 29 bytes forever**.
**While it is in this state it is busy placing a call, not listening for
us.** This is almost certainly what BE9558H was doing too — we simply never
turned on ALEOS_SERIAL debug in May to look. It is not a different disease;
it is the same one, seen properly for the first time.
It is also the argument for Method A in one picture: the unit is mid-dial
every ~75 s, and our inbound Stop has to thread the gaps between those
attempts. Give it somewhere to dial and the problem inverts into a
deterministic one.
### Why `slow_drip` lied
`slow_drip` returned the *success* signature except for the one field that
mattered:
```json
{"duration_s":120.0,"drips_sent":38,"bytes_sent":920,
"bytes_received":0,"send_error":null}
```
Full duration, no broken pipe — but zero bytes back. Cause is in the log
above: each 75 s cycle re-runs `Initialize Auto answer on port 9034`, which
orphans the held session (`data in for unknown reason 3 removing from
select`, `OnMsg recv error: 107 - Transport endpoint is not connected`). Our
local TCP stayed open so `sendall` never raised — but the modem stopped
bridging after the first re-init, so every drip after that went into a socket
nobody was reading.
⚠ **`send_error: null` + full duration is NOT success. Only
`bytes_received > 0` is success.**
⚠ **In fairness to slow_drip: it got exactly one attempt here**, run ~90 s
after a modem reboot, with a dead session visible in the log at 20:19:17 in
that same window. BE9558H took hours of attempts before one landed. Method B
was not ruled out on BE12599 so much as abandoned in favour of something that
doesn't need luck.
---
## ⚠ Two red herrings that cost ~90 minutes
### 1. The trusted-IP whitelist (this was the real reason inbound never worked)
The RV50s run with **Security → Trusted IPs (Friends List) enabled**. A
source IP that is not on the list is dropped **silently** — inbound presents
as `Connection error: timed out`, never a refusal.
Brian's dev-box public IP is **dynamic** and had changed, so `tmi-dev` was no
longer whitelisted. Every inbound attempt failed identically across four
different modem and device states, which looked exactly like the BE9558H
mode-flipping symptom and sent us chasing modem configuration for over an
hour.
**Check this before diagnosing anything else.** Note that SFM in Docker
egresses via the *host's public IP*, not its LAN IP.
### 2. A 502 from SFM does not mean TCP connected
`sfm/server.py` raises **502 for both** failure classes:
```python
raise HTTPException(status_code=502, detail=f"Protocol error: {exc}")
raise HTTPException(status_code=502, detail=f"Connection error: {exc}")
```
We read an early 502 as "TCP connected, modem bridged, device mute" and built
a whole theory on it. It was almost certainly a connect timeout.
**Always read the `detail` string** — "connect failed" and "device didn't
answer" are completely different problems and the status code will not
separate them.
---
## What actually worked — invert the direction
The key observation is in the log above:
> `TCP recvhost ... state TCPMode::kClosed` → `Connect to IP: 0.0.0.0 Port 0`
**The modem auto-dials its Destination whenever serial data arrives while
closed.** So instead of fighting for inbound, give it somewhere to dial:
point `Destination Address` at our own `ach_server` and the device's own
75-second attempts become **device-initiated sessions the modem bridges
correctly**. No race, no contention, worst case a 75-second wait.
### Procedure
1. **Run the rescue server** on a host the modem can reach (public IP +
forwarded port):
```bash
cd /home/serversdown/seismo-relay
.venv/bin/python -u bridges/ach_server.py --port 12345 \
-o bridges/captures/<unit>-diag --stop-monitoring -v
```
2. **Point the modem at it** — ACEmanager → Serial → Port Configuration →
`Destination Address` = your public IP, `Destination Port` = 12345.
3. **Wait for the call-in.** `--stop-monitoring` fires SUB 0x97 at step 1.5,
after the handshake and *before* the event walk. Confirm via
`rescue.json` in the session directory:
```json
{"peer": "166.246.64.226:60921", "stop_monitoring": "ok"}
```
4. **Restore the modem's Destination** once you are done, then finish the
device side (disable ACH, erase) through whichever channel works.
On BE12599 the first call-in landed at 20:58:11 and reported
`stop_monitoring: ok`; a second at 20:58:20 confirmed it. `is_monitoring:
false` was still true **6½ hours later** — the fix is durable.
---
## Hard-won gotchas (do not re-derive)
- **Never leave the Destination pointed at a host with nothing listening.**
That is the worst state available: the device still dials, the modem still
flips, inbound stays blocked, and nothing is delivered. An 8-minute gap
with the listener down produced a spurious inbound timeout that cost
another round of misdiagnosis.
- **Stopping monitoring removes your call-in channel.** ACH is "after event
recorded"; no new events means no new dials. The backlog sitting in memory
does *not* re-arm it. After a successful stop the unit goes quiet and you
need the modem cycled (works — produced a call-in), the scheduled daily call
(BE12599 calls at **05:00:14 device-local**, per §8e), or working inbound.
**Plan the order before you fire the stop.**
- **`--events-only` silently breaks dedup.** It skips the device-info step,
so the serial is never read; `ach_state.json` then keys on
`peer:ephemeral_port`, which is unique per connection. Every session looks
like a new unit, starts from key 0, and re-downloads the same event. Four
sessions on BE12599 downloaded the identical event four times and made zero
progress on the backlog. Events also file as `serial=UNKNOWN` with a
`M000…` BW filename (serial_numeric 0) instead of `N599…`.
**Do not use `--events-only` when you intend to download anything.**
- **`/device/events/index` reported `lifetime_count: 0`** on a unit with years
of history. Suspected decode bug in the SUB 0x08 field offset — do not
trust that number. The 88-byte payload is preserved in the `raw_hex` field
if someone wants to chase it.
- **Memory used cross-checks the event keys exactly:**
`last_key − buffer_start = memory_total − memory_free`. On BE12599:
`0x011230ec − 0x01110000 = 78,060` and `983,028 − 904,968 = 78,060`.
Useful sanity check that you are reading the keys right.
---
## Final state (2026-09-17 ~01:30 local)
- `is_monitoring: false`, held 6½ hours
- Battery 6.76 V
- Memory 78,060 / 983,028 bytes used (8%)
- `first_key 01121728`, `last_key 011230ec` — ~6.6 KB of addressable event
chain, roughly 3 events
- ACH still **enabled** — to be disabled after the backlog is preserved
- Modem Destination still pointed at tmi-dev — to be restored
- ⚠ **Do not re-enable ACH until the connector is serviced.** Tran is still
sitting at 0.400 and the loop restarts the moment monitoring resumes.
-150
View File
@@ -1,150 +0,0 @@
# SFM — where it actually stands as a tool
**Status as of 2026-09-20 (v0.31.0).** This is the honest assessment, not the
roadmap — `README.md § Roadmap` covers where it is *going*. Expect this file to
go stale; re-date it when you revise it.
---
## The framing
SFM is **three different things wearing one name**, at three very different
levels of maturity:
| | what it is | maturity |
|---|---|---|
| **The codec library** | `minimateplus/`, `micromate/` — bytes in, `Event` out | **Production.** Verified per-sample at scale. |
| **SDM — the data side** | the DB, waveform store, `/db/*`, ingest | **Production.** Terra-View depends on it daily. |
| **SFM — the device side** | `/device/*`, live connections to units | **Emergency-grade.** Works, but manual, unauthenticated, and thinly tested. |
| **The lab** | `seismo_lab.py`, `scratch/`, the Inspector | **Research artifacts.** Useful, not products. |
Brian's own description — *"right now it's an emergency tool and a research
project"* — is accurate, and it applies specifically to the **device side**.
The data side is not an emergency tool; it has been carrying production for
months.
Most confusion about "is SFM reliable?" comes from answering for the wrong
tier.
---
## 1. What you can rely on
### Production-grade — trust it
- **Series-3 decode.** 14,338 / 14,338 files decode per-sample exact against
preserved Blastware ASCII exports, 45 units, files back to 2018.
- **Series-4 (Thor) decode.** 1,057,536 / 1,057,536 geo samples exact against
Thor's own CSV exports; production IDFW 575/575 with zero truncations.
- **Histogram decode.** 1,211 / 1,211 production histograms exact, including
842,442 per-interval frequency comparisons with zero mismatches.
- **The ingest path.** `/db/import/blastware_file` and `/db/import/idf_file`
fed by the watchers — this is how prod actually gets its data, and it has
been running unattended for months.
- **`/db/*` read API.** Always-on, consumed by Terra-View for every fleet
listing, event detail and report.
- **The waveform store** — `.h5` + `.sfm.json` sidecars + retained raw
binaries, with operator review state preserved across regeneration.
- **`bridges/ach_server.py`** — speaks the full BW protocol to calling units.
Proven in the field, including as a rescue tool (see the runbook).
### Emergency-grade — works, but you are the error handling
- **`/device/*` live endpoints.** They do what they say. But they are
synchronous, unauthenticated, and a single cellular download can exceed the
60 s timeouts that sit in front of them.
- **The rescue ladder** (`rescue`, `stop_monitoring_*`, `events/erase`).
Each has worked in a real incident — but each has been used a handful of
times, by one person, with the runbook open.
- **The standalone webapp.** Perfectly usable, and as of v0.31.0 the cheap
probes and rescue actions are reachable without curl. No auth of any kind.
### Research artifacts — useful, not products
- **`seismo_lab.py`** — 2,789 lines of Tkinter (Bridge / Analyzer / Query DB /
Inspector). Desktop-only, single-user, no tests.
- **`scratch/`** — the verification harnesses (`verify_against_ascii.py`,
`verify_thor_against_csv.py`) and the offset detector (`offset_scan3.py`).
These produced the numbers the production claims rest on, so they matter —
but they are analysis scripts, not maintained code.
- **`docs/offset_investigation.md`** — an open investigation, not a feature.
---
## 2. What to use when
| you want to… | use | notes |
|---|---|---|
| Know if a unit is monitoring / its battery / memory | `GET /device/monitor/status?force=true` | ~2 s |
| Know whether ACH is on | `GET /device/call_home` | ~2 s. **Not** `/device/events`. |
| See how full a unit's buffer is | `GET /device/events/storage_range` | ~2 s, no chain walk |
| Stop a runaway unit | Diagnostics tab → Stop Monitoring | see the runbook first |
| Reach a unit that will not answer | **point its modem at an `ach_server` and answer its call** | runbook Method A — do not race it |
| List a unit's stored events | Events tab → Load events | **slow**, and broken past 64 KB (below) |
| Get event data into the DB | the watcher → `/db/import/*` path | not the live walk |
The single most useful habit: **the cheap probes are cheap and the event walk
is not.** Reaching for `/device/events` to answer a yes/no question about a
unit is the mistake that motivated the v0.31.0 webapp changes.
---
## 3. Known issues
| issue | impact | status |
|---|---|---|
| **5A walk dies once a unit's buffer crosses 64 KB** | `/device/events` 500s; event body never downloads | Known, documented in `CLAUDE.md`. Needs a BW capture of a spanning event to fix properly. |
| **No auth on SFM at all** | 21 `/device/*` endpoints, including destructive ones, open to anything that reaches the port | Design agreed (Terra-View as authenticated jump host); not built. |
| **Swagger try-it-out is live on destructive endpoints** | `POST /device/events/erase` is one click away at `:8200/docs` | Partially mitigated: the webapp's erase now requires typing the serial. `/docs` itself is unguarded. |
| **`SUB 0x08` lifetime counter reads 0** | `/device/events/index` returns a meaningless number | Suspected field-offset bug. Surfaced in the UI as "unreliable". |
| **Long device operations are synchronous** | 60 s timeouts in `routers/sfm.py` and the reverse proxy; a full download exceeds both | Known design constraint. Must be POST-starts-job / GET-polls before any remote lab. |
| **`backfill_sidecars.py --force` silently inserts DB rows** | store files with no DB row get one; the dry-run does not report the count | Known. Avoid `--force` — `TOOL_VERSION` gates regeneration anyway. |
| **14 sensitive-range files show an exact 8× discrepancy** | 10.0 / 1.25 — a units problem, not a decode problem | Open, not blocking. |
| **16 failing tests on `dev`** | 15 need gitignored fixture bundles; 1 is real (`sc["peak_values"]["transverse"]` returns `None` where `0.0` is expected) | The real one shipped in v0.31.0. |
---
## 4. What stands between this and a real tool
Roughly in dependency order — each unblocks the ones below it.
**1. Authentication.** Everything else is gated on this. SFM has none, and
the modem IP whitelist gives zero protection because SFM *is* the whitelisted
origin. The agreed design delegates rather than builds: Terra-View becomes the
authenticated jump host (`/api/sfm/*` already inherits deny-by-default operator
auth), and the `8200:8200` publish is dropped so Terra-View is the only door.
**2. Async long operations.** POST starts a job, GET polls. Retrofitting this
after building a remote lab on top of synchronous endpoints would be far worse
than designing for it now.
**3. Confirm-guards on the remaining destructive endpoints.** Auth answers
*who*, not *did you mean it*. The webapp's erase is guarded; the other seven
destructive POSTs and `/docs` are not.
**4. The 5A page-boundary fix.** Until this lands, live event download is
unreliable on exactly the units most likely to need attention — the ones that
have been recording heavily. Wants a Blastware capture of an event spanning a
page boundary before the chunk-addressing half is trustworthy.
**5. A live Thor / Micromate client.** The device side is MiniMate-only.
Series-4 units can only be read from forwarded files, so half the fleet has no
live path at all.
**6. Test coverage that runs from a clean checkout.** 15 of 16 current
failures are missing fixture bundles. A test suite that cannot go green on a
fresh clone cannot gate anything.
**7. The SDM rename.** Cosmetic relative to the above, but the longer `sfm/`
holds the data-side code the more the tiers blur. ~30–50 files here, ~10–15 in
Terra-View, plus a Docker volume migration. Do it when the codebase is quiet.
---
## The short version
The **data side is a real tool already**. The **device side is a set of sharp
instruments** that work in the hands of the person who wrote them, with the
runbook open. The gap between those two states is mostly **auth, async, and
guardrails** — not protocol work. The protocol is the part that is actually
finished.
@@ -1,134 +0,0 @@
# Plan — "Rescue Listener": a first-class tool for the inverted rescue
**Status:** proposal, not started. Written 2026-09-17 ~01:40 local, straight
off the BE12599 incident. Open questions at the bottom need Brian's answer
before anything is built.
**Background:** `docs/runbooks/wedged_unit_recovery.md`, "Second incident —
BE12599". The manual version of this worked; this plan is about making it a
tool instead of a sequence of remembered steps at 1 AM.
---
## The problem, stated plainly
When a unit is wedged in the BE12599 mode — geophone offset above trigger,
recording back-to-back, ACH dialing constantly, device stuck repeating an AT
modem-init string and therefore **deaf to S3 over inbound** — the only channel
that works is the one the *device* opens.
Recovering it currently means:
1. Remember that `bridges/ach_server.py` exists and takes the right flags
2. Start it by hand on a box the modem can reach, with a public port forwarded
3. Go into ACEmanager and repoint the modem's Destination
4. Watch a terminal for a call-in
5. Read `rescue.json` to find out whether it worked
6. Go back into ACEmanager and repoint the modem to where it belongs
7. **Not forget step 6**, because leaving the Destination pointed at a dead
listener is worse than never having started
That is six manual steps and one landmine, executed under pressure while a
unit floods the office server.
## What the tool should be
**A "rescue listener" an operator can start for one unit, which handles
whatever that unit says when it calls in, and refuses to go away until the
operator confirms the modem has been pointed back.**
Lifecycle:
1. **Start** — operator names the target unit and starts a rescue listener.
The tool reports the exact address/port to enter in ACEmanager, plus the
actions it will take.
2. **Operator repoints the modem** to that address.
3. **Wait** — listener sits there. Live status: "waiting for call-in",
elapsed, last-seen.
4. **Act** — on call-in, run the configured rescue actions automatically,
in a safe order, each independently guarded. Report per-action outcome.
5. **Hold** — the listener **stays up** and keeps reporting, because the
modem is still pointed at it.
6. **Confirm & stop** — the operator explicitly confirms the Destination has
been restored (to `0.0.0.0`, or to the office Instantel ACH server).
Only then does the listener shut down.
Step 6 is the whole point of making this a tool. It is the step that is
easiest to skip and most expensive to skip.
## Default action set
Ordered deliberately — see "order matters" below.
| # | Action | Default | Why |
|---|---|---|---|
| 1 | **Stop monitoring** (SUB 0x97) | ✅ on | Halts recording; ends the trigger→record→dial loop at its source. Already implemented as `--stop-monitoring`. |
| 2 | **Drain events** to a diagnostics store | ⚙ configurable | The backlog is usually evidence, not garbage — see the BE12599 offset investigation. Must NOT land in the prod SFM DB. |
| 3 | **Disable ACH** (SUB 0x2C/0x7E/0x7F) | ❌ off by default | Stops the dialing — **and stops your only channel**. Opt-in, and ideally gated on step 1 having succeeded. |
| 4 | **Erase events** | ❌ off by default | Destructive. Only after a verified drain. |
### Order matters — the lesson from BE12599
Stopping monitoring *removes the call-in trigger*. ACH fires on "after event
recorded"; with recording stopped, the unit has no reason to dial again, even
though the backlog is still sitting in its memory. So a naive
"stop + disable + erase, all at once" rescue can silence the unit before
you've collected anything, leaving you with no channel and a device full of
evidence.
The tool should either sequence around this or warn loudly about it. My
instinct is: **stop monitoring immediately** (it's the bleeding), then drain
across however many call-ins it takes, and treat disable-ACH/erase as a
separate, explicit "finish" action once the operator is satisfied.
## Where it should live — open question, with a proposal
The natural tier is **SFM** (device-side, per the three-tier model in
CLAUDE.md). But the rescue listener must be reachable *from the cellular
network*, which is a deployment constraint SFM's usual profile doesn't have.
**Proposal worth considering:** run it at the office, beside the real Instantel
ACH server, on a **different port** (e.g. 12346 while Instantel holds 12345).
Then the ACEmanager change is a **port change, not an IP change** — smaller,
faster, less to get wrong, and trivially reversible. It also means the office
public IP (already stable and known) is the destination, rather than whatever
Brian's dynamic home IP happens to be that week.
The tmi-dev approach used on BE12599 worked, but required a router forward and
ran into the dynamic-IP problem in the same session.
## Open questions
1. **Where does it run?** Office beside Instantel ACH (port swap), SFM on the
NAS, or ad-hoc on tmi-dev? Affects everything else.
2. **What drives it?** Terra-View admin page (fits "operator UI"), an SFM
endpoint pair (`POST /device/rescue_listener/start` + `/stop` + `/status`),
or a CLI wrapper? A long-lived listener doesn't fit the request/response
endpoint shape well — probably needs a background task with a status poll.
3. **How does it identify the unit?** It can't know the serial until the
device calls in and the handshake reads it. Allowlist by modem IP? Accept
anything and report what showed up?
4. **Where do drained events go?** A per-incident diagnostics store
(`bridges/captures/<unit>-diag`) seems right — explicitly *not* the prod
SFM DB. Does that store need to be a first-class thing with its own
retention, or is a directory fine?
5. **How is "confirm the modem is repointed" verified?** Operator attestation
(a button), or can we actually probe it? If the listener stops seeing
call-ins that's weak evidence; if inbound to the unit starts working that's
stronger.
6. **Multi-unit?** One listener per incident, or one listener that handles any
unit that dials in? Probably the former for safety.
7. **Timeout / abandonment policy.** If nobody ever confirms, does it run
forever? Alert after N hours?
## What already exists
- `bridges/ach_server.py` — the listener itself, with `--stop-monitoring`,
`--disable-ach`, `--rescue` (added on `feat/ach-rescue-on-connect`, commit
`9f1050b`), `--clear-after-download`, `--max-events`, `--allow-ip`.
- Per-session `rescue.json` recording per-action outcomes.
- Isolated per-output-dir SQLite + waveform store, so a diagnostics capture is
already separate from prod by construction.
So the gap is not protocol work — it's lifecycle, operator surface, and the
confirmation gate. Most of the risk is in questions 1 and 2.
File diff suppressed because it is too large. Load diff
File diff suppressed because it is too large. Load diff
@@ -1,538 +0,0 @@
# SFM: Series-4 parity and a device safety layer — design
**Date:** 2026-10-20 · **Branch:** `feat/series4-sfm-parity` · **Status:** draft for review
**Decided with:** Brian, in conversation 2026-10-19/20.
## In plain terms
SFM can already *read* a Micromate almost as well as it reads a MiniMate, but
only through the Python library and bench scripts. SFM's web endpoints still
only speak Series 3. This design does three things:
1. Gives Series 4 the same everyday jobs in SFM that Series 3 has: identify a
unit, check its status, read its settings, list and download events,
start/stop monitoring, and change its settings.
2. Adds a **safety layer** every device request goes through. It makes sure a
command only reaches the unit it was meant for, logs every change, and
checks every change by reading the unit back.
3. Lets SFM **stay on the line** with a Micromate. It calls up once, confirms
the serial, and keeps the connection open for later commands instead of
reconnecting each time.
**The guiding principle (Brian): talking to a Series 3 unit and talking to a
Series 4 unit is the same for the user.** It is the same screens, the same
endpoints, the same way of naming a unit, and the same shape of answer. The
only visible difference is the serial (`UM…` vs `BE…`) and the settings each
model has. The differences live underneath, in one adapter per series.
It does **not** cover the emergency tools (runaway-unit stops, rescue, erase),
the call-home receiver, or anything async. Those come later, as features
shared by both series.
**Production reach, stated honestly:** while THOR is set to stay connected to
production Micromates, a modem's single connection is taken. SFM can't reach
those units until THOR lets go or SFM takes over call-home. In this phase,
Series-4 SFM is for the bench and for units THOR is not holding.
---
## Decisions
| decision | why | who |
|---|---|---|
| **One user experience for both series** | the user's method is identical; only the serial prefix and each model's settings differ; adapters absorb the rest | Brian |
| Match **jobs**, not endpoints | some Series-3 endpoints only exist to work around Series-3 quirks | agreed |
| **No Series-4 emergency tools** yet (runaway stop, rescue, erase) | Micromates rarely need them | Brian |
| The series comes from the **serial prefix**: `UM` = Micromate, `BE` = MiniMate Plus, `BA` = Blastmate | the prefixes are definitive, so there is no probing | Brian |
| Before any **write**, confirm the unit that answered is the one named | SFM addresses units by IP; a moved modem or stale IP means a different unit answers | agreed |
| **Synchronous** endpoints for now; async later, for both series together | parity first, then shared features | agreed |
| **No library of setup files on the PC** (unlike THOR). The unit's own settings are the truth: SFM reads them from the unit, and verifies every push by reading the unit back | THOR keeps one copy of each setup on the PC and another on the unit, linked only by file name. Nothing checks the contents match, so the PC's `test2` and the unit's `test2` can say different things | Brian |
| **Sessions for Series 4 now; Series 3 only after a bench test** | THOR holds Micromate lines daily without harm; a MiniMate's hangup/DCD behaviour is untested | Brian |
| Audit log in **SFM's database** (new table) | Terra-View can show it; it fits the existing `CREATE TABLE IF NOT EXISTS` pattern | proposed |
---
## Scope: the parity table
Rows 8 and 11 of the original inventory (runaway stops, rescue/erase) are out
of scope by decision. Row 6 (monitor log) moved to the parking lot: it is its
own piece of work, together with call-in monitor-log ingest.
| # | job | Series 3 in SFM today | Series 4: protocol status | Series 4 in this phase |
|---|---|---|---|---|
| 1 | Identify a unit | `/device/info` (walks the whole chain, slow) | implemented: `connect()` | dispatch to the Micromate client |
| 2 | Quick status (monitoring, battery, memory, clock) | `monitor/status`, `storage_range`, `events/index` | implemented: `get_state()`; the `0x06` event count is decoded only in the bench tool | same endpoints; move the count decode into the client |
| 3 | Read settings | compliance in `/device/info`; `GET /device/call_home` | `get_setup()` implemented and verified on hardware; call-home: enable + dial string observed, rest unmapped | setup in full; call-home returns enable + dial string + raw |
| 4 | List events | `/device/events` (downloads every event to list them) | implemented, and cheap: the chain walk returns sizes | the same event-list shape as Series 3, each event carrying an `event_id` |
| 5 | Download an event | `/event/{i}`, `/waveform`, `/blastware_file` | implemented: streams the `.IDFW`/`.IDFH` itself, with a decode self-check | the same download and save-to-DB actions as Series 3. Underneath, Series 4 saves through `/db/import/idf_file` |
| 7 | Start / stop monitoring | `monitor/start`, `monitor/stop` | mapped, identical to Series 3 (`0x96`/`0x97`, acks `0x69`/`0x68`); never sent | **first write.** Verify with `0x49` state |
| 9 | Change call-home settings | `POST /device/call_home` | write mapped (`0x2C` → `0x7E`/`0x7F`, same as Series 3); field map mostly unknown | enable/disable only; the rest waits for the THOR round |
| 10 | Change recording settings | `POST /device/config` | sequence mapped (`0xDA` → `0x68/73` → `0x82/83` → `0x71/72`); no encoder | read-modify-write, stop → push → restart, verify with `get_setup()` |
---
## Architecture
### One door for every device request
A new module, `sfm/device_access.py`, sits between the `/device/*` handlers and
the two device libraries. No handler opens a transport or picks a library
itself any more.
```
/device/* handler
│ (serial, address, action, tier)
▼
device_access ── series from serial prefix ── session / per-unit lock
│ │ │
│ ▼ ▼
│ minimateplus (S3) or micromate (S4) audit table
▼
read-back verification (changes only)
```
- **Naming a unit is the same for both: `serial` + address.** The prefix picks
the adapter: `UM` → Series 4 (`micromate`); `BE` or `BA` → Series 3
(`minimateplus`); any other prefix → 422. A request with no `serial` is
treated as Series 3. That is a **legacy path** kept only so existing scripts
keep working; the webapp and every new caller always send `serial`.
- **One contract.** Same `/device/*` paths, same request parameters, and
**the same response models for both series**:
- `UnitInfo`, `UnitStatus`, `UnitSettings`, `EventRef`, `ChangeResult`
- Anything only one series has goes under a `detail` object inside the same
model, never as a different top-level shape. `"series": 3 | 4` is
informational.
- **Events have one identity.** An opaque `event_id` string from the event
list, passed back to download it. Underneath it is Series 3's position or
Series 4's device key, plus the serial; the user never handles either.
- **Not-yet-supported is uniform.** If one series can't do something yet,
the endpoint still exists and answers **501 "not supported for Series N
yet"**. It is never a missing route or a different call.
- **Work separate from HTTP.** Each operation is a plain function taking the
session. The handler is a thin wrapper, so making an operation an async job
later means changing the wrapper, not the operation.
### Adapters
Each series implements the same operation set behind `device_access`:
| operation | Series 3 adapter | Series 4 adapter |
|---|---|---|
| `identify` | STARTUP + serial + config | `connect()` |
| `status` | `0x1C` (+ `0x06`) | `get_state()` + `0x06` count |
| `read_settings` | `0x1A` compliance decode | `get_setup()` |
| `list_events` | today's walk | chain walk (cheap) |
| `download_event` | 5A → Blastware file | 5A → `.IDFW`/`.IDFH` |
| `start` / `stop` | `0x96` / `0x97` (exists) | `0x96` / `0x97` (new) |
| `read_call_home` / `set_call_home_enabled` | exists | `0x2C` / `0x7E`+`0x7F` |
| `push_settings` | `/device/config` path (exists) | setup push (new) |
| `call_up` / `hang_up` | connect-per-request underneath, until the bench test | held session |
Each adapter maps its native data into the shared models. `UnitSettings` keeps
the fields both series have under the same names and units: record mode,
sample rate, record time, histogram interval, trigger levels, the notes as
label → value. Model-specific fields go under `detail`.
**Requests that include `serial` get the shared models; requests without it
keep today's Series-3 shapes, unchanged.** Nothing breaks in between: the
webapp moves to `serial` in phase 1c, and the old path retires after that and
after `watch_unit.sh` moves. Terra-View does not call `/device/*`. The
emergency endpoints (`stop_monitoring_*`, `rescue`, `events/erase`) are not
touched and stay Series-3 only; a `UM` serial gets 501.
### The webapp
The same screens for both series. You name a unit by serial + address (today
it takes host/port only), and the series shows as a badge, nothing more. Read
panels for both series land in phase 1; each write button appears for Series 4
in the phase that adds that write.
### The safety layer
**Tiers.** Every operation declares one:
| tier | examples | what the layer does |
|---|---|---|
| read | info, status, setup, events, download | runs; no identity check |
| change | start/stop, call-home, setup push | identity check → audit → send → **read back** → audit the result |
| destructive | delete, erase (none in this phase) | everything above + the caller must send the unit's serial as `confirm` |
**Identity check (changes only).** Before the first change in a connection,
compare the serial the unit reports with the one requested; on a mismatch,
refuse (409) and send nothing. Series 4 already reads the serial in
`connect()`. A Series-3 change adds one serial read (`SUB 0x15`), about one
round trip.
**Opcode guard.** A send-side check that refuses known cross-series
collisions. It starts with **`0xA2`**, which is CONFIRM ERASE on Series 3 and
"end call-home" on Series 4. This phase never sends `0xA2`; the guard makes
that impossible by accident. The table of colliding opcodes lives in one
place.
**One connection per unit.** A per-unit lock keyed by address
(`tcp:host:port` / `serial:port`). A request for a busy unit waits up to
**20 s** (configurable; under Terra-View's 60 s proxy timeout), then gets
**423 "unit busy"** instead of opening a second connection. This applies to Series 3 as well. The webapp's Diagnostics
refresh currently fires three device requests at once against a modem that
allows one; under the lock they queue.
**Read-back verification.** A zero-data ack has never been proof that a write
applied. Every change is followed by a read:
- start/stop → `0x49` state: start expects `0x02`, stop expects `0x00`. Record
the value either way; `0x03` is the in-call-home state
- call-home → re-read `0x2C` and compare the edited bytes
- setup push → `get_setup()` and compare every field that was set
A mismatch is reported as a failed change (and audited as one), even if the
ack was clean.
**Errors that say what happened.** Distinct responses for:
- 503: couldn't connect
- 504: connected but the unit didn't answer
- 423: unit busy
- 409: wrong unit
- 422: bad input
- 502: the reply was malformed
Today 502 covers both of the first two.
**Audit table.** New table `device_commands`, created on startup like the
others. It is additive, but still a schema change, so the changelog says so.
One row per change attempt:
| column | content |
|---|---|
| `ts`, `serial`, `series`, `address` | who and where |
| `action`, `tier` | e.g. `monitor_stop`, `change` |
| `request` | parameters, plus hex of what was sent |
| `ack` | reply summary |
| `verified` | read-back result: `ok` / `mismatch` / `not_checked` |
| `outcome`, `error` | final result |
| `caller` | best-effort origin (`webapp`, `terra-view`, `script`) |
Reads are not audited.
### Sessions
1. **Call up.** Connect, `connect()` (POLL / SERIAL / STATE), identity check
against the requested serial.
2. **On the line.** Requests for that unit run in turn on the same connection,
behind the per-unit lock.
3. **Keep-alive.** A POLL every 60 s while idle. The ACEmanager TCP idle
timeout is 2 min.
4. **Hang up.** On `POST /device/hangup`, after 5 idle minutes, or on any
transport error. A reconnect is a new session with a new identity check.
5. **Ring safety.** If `RADIO RING` arrives on an SFM session, log it and hang
up **immediately**. Until SFM is the call-home destination, the unit's
retry should reach THOR. 🔶 *Inferred:* the unit retries; its `0x2C`
retries field reads 3.
**Call up and hang up are the same for both series.** Underneath, the
Series-3 adapter keeps today's connect-per-request behaviour until the bench
test under *Testing*; the user sees the same actions either way.
### Series-4 write path
**Encoder.** Extend `micromate/framing.py`:
- a request builder that carries a data section
- the same escape set `{02,03,04,10}`, applied to data, params and checksum
- plain SUM8 of the destuffed payload (*not* Series 3's write format)
Rules: `micromate_protocol_reference.md` → *The escape set — exactly four bytes*,
*Checksum — plain SUM8 of the de-stuffed payload*, *Write-frame destuffing*.
**Dry run.** Every Series-4 write accepts `dry_run=true`. It returns the exact
frames it would send and sends nothing. The first live send of each write is
reviewed this way first.
**Per operation:**
| operation | frames | verify | open questions it settles |
|---|---|---|---|
| start / stop | `0x96` / `0x97`, offset `0xFFFF`, zero params | `0x49` | the ack when already in that state |
| call-home enable/disable | read `0x2C` → `0x7E` (126 B content, offset `0x007E`) → `0x7F` | re-read `0x2C` | none new; bit 0 of `write[5]` |
| setup push | read `0x08`, `0x2E`, `0x1A` → `0xDA` (name) → `0x68`/`0x73` → `0x82`/`0x83` → `0x71`/`0x72` | `get_setup()` | the offset rule; whether `0x68`/`0x82` are needed |
**Setup push, details:**
- Read-modify-write of **all three** blocks, as THOR appears to do.
🔶 *Inferred from two captures:* `0x68` = the preferences content with
`[0:3]` zeroed; `0x82` = the `0x2E` content with `[0:3]` and the CRC slot
zeroed; `0x71` = the `0x1A` content `[0:2090]` with the length echo zeroed.
- Offsets come from THOR's observed constants. 🔶 The hypothesis "offset =
the read block's length + 2" fits all four, but each has been seen at one
size only.
- The edited fields come from `MicromateSetup` and are written back at the
offsets `setup_block.py` already uses. Only fields graded **measured** may
be edited.
- Sequence: stop monitoring (if running) → push → restart (if it was running)
→ verify. THOR's "must be idle" is policy, not the device, but stopping
first removes a variable from the first live write.
- ⚠ **Edit-buffer hazard.** `0x1A` reads the keypad's unsaved edits, so a
read-modify-write taken while someone is in the menu would commit them.
This can't be detected from the wire; it is documented in the endpoint and
audited.
- **Target file:** the active setup, overwritten in place, by default. A
named target is allowed, but overwriting a *non-active* setup or
`factory.MMB` is untested, so it is refused in this phase.
---
## Testing
**Offline (CI-capable):**
- **Frame reproduction.** The new encoder must reproduce THOR's captured write
frames byte for byte: `0x96`/`0x97`, `0x7E`/`0x7F`, and the full setup push,
from the 9-24 / 9-25 / 10-14 captures. This is the same method that proved
the reads (218/218). The needed frames are copied into force-added fixtures,
since `bridges/captures/` is gitignored.
- **Safety layer on fakes:**
- series by prefix
- identity mismatch → 409, nothing sent
- `0xA2` refused
- lock → 423
- read-back mismatch → failed change
- audit row written for every change attempt
- RADIO RING → session ends
- **Endpoints** through FastAPI's `TestClient` against the scripted transport
already used in `tests/test_micromate_client.py`.
- **Contract tests.** The same test, run against both adapters with fakes,
asserts that each job returns the same model with the same field names and
units. A field present for one series and absent for the other is a test
failure unless it lives under `detail`. This is the test that keeps the
guiding principle true as the code grows.
**Bench (UM20147, with Brian):** each write's first live send follows the same
protocol:
1. Dry run.
2. Review the frames.
3. Send once, with a capture running.
4. Read back.
5. Write the result into the reference.
Order: stop/start → call-home off/on → setup push of one field → setup push of
several fields.
**Series-3 session test (before Series-3 sessions are built):** hold a call-up
session open to a MiniMate that is monitoring, for several minutes. Record:
- does it keep monitoring (does an event still record)?
- after hangup, is it monitoring?
- does it behave differently on an RV55 with the DCD issue?
---
## Build phases
Each safety piece arrives with its first real use, so nothing sits untested.
1. **One contract, reads only.** `device_access.py`, the two adapters, the
shared models, series selection, the per-unit lock, the error mapping, and
sessions with ring safety. Rows 1–5 for **both** series through the same
endpoints. **No writes.** Split into three plans:
- 1a. The foundation plus identify / status / settings for both series.
- 1b. Event list and download for both series (rows 4–5). Decided with
Brian 2026-10-21:
- **MiniMate events are listed from their headers** (`0A` + `1E` arm +
`0C` + `1F` browse, no `5A`) instead of downloading every event to list
it, and one event downloads without the ones before it. It reuses the
bypass `skip_waveform_for_events` already takes, so no new command
reaches the wire. The legacy serial-less `/device/events` keeps its
full-download walk. 🔶 Unproven on a unit: **a MiniMate bench check is
owed before this branch merges.** Its scope (final review,
2026-10-21):
- a list of three or more events, confirming `1F(browse)` advances
after a `1E(arm)` without `1F(arm)`;
- a non-first event;
- a histogram-mode event, capturing its `0C` (which would let Series
3's `record_type`, `null` today, be decoded);
- an event past 64 KB, expecting the named 502;
- a stale-id download, confirming no `5A` goes out;
- a dropped reply, via `bridges/mm_link.py`-style fault injection.
- **Download = fetch, check, store** in SFM's database, the same as
Series 3's `blastware_file` route, and returns the stored row's id. The
file and waveform are then served by the existing `/db/events/{id}/…`
routes. The database matches on (serial, timestamp), so storing an
event already stored, including one THOR's watcher forwarded, ~~refreshes
the row instead of duplicating it~~. **Changed by the final review
(2026-10-21):** it returns the existing row and writes nothing
(`inserted: false`, `detail.already_stored: true`). Never merge: the
watcher's copy, with its paired report, is the richer one, and a
refresh measurably downgraded it (PVS, project strings and ZC
frequencies went NULL).
- **`event_id` = `<serial>:<key>:<YYYYmmddHHMMSS>`.** Both series reuse
keys (after an erase, and across Micromates), so a download whose key
now holds a different event fails with 409 instead of fetching it.
- **Micromate downloads walk to the event first** (the only order captured
from THOR), with THOR's 1,024-byte chunks.
- 1c. **The webapp:** serial + address, and the same read panels for both
series.
- **HARD PREREQUISITE:** before any poller or webapp sends `serial`, add a
per-address cool-down after a RADIO RING: call-ups to that address answer
503 + `Retry-After` until it expires, and `POST /device/hangup` clears it.
The length must come from the unit's measured call-home retry timing (a
bench test). Without it a poller can re-grab the modem's single TCP
session through every retry, and the call never reaches THOR.
2. **Encoder + opcode guard + dry run + frame-reproduction tests.** Still
nothing sent.
3. **Start/stop monitoring** (row 7): the first live write, at the bench.
Brings the identity check, the audit table and the read-back framework.
4. **Call-home enable/disable** (row 9).
5. **Setup push** (row 10): one field first, then several.
Each phase is its own implementation plan. **All phases land on
`feat/series4-sfm-parity` and merge to `dev` once, when everything here is
implemented** (Brian, 2026-10-21) — not one merge per phase.
---
## Out of scope (this phase)
- Series-4 emergency tools: runaway stops, rescue, per-event delete, erase.
(Erase-all is also unmapped.)
- Async jobs; auth (Terra-View as jump host); the call-home receiver. These
are shared features for later.
- Scheduler read/write/enable; clock set; remote sensor check; restart;
firmware.
- Series-3 sessions, pending the bench test.
- Mapping the rest of `0x2C` (the THOR round).
## Fix list (found 2026-10-19, separate small changes)
- `bridges/ach_server.py:524`: `seen_keys` is undefined. Series-3 call-home
monitor-log collection has failed every session since `9afa348`
(2026-05-07).
- `bridges/mm_ach_server.py:262`: `_cstring`/`_content` aren't imported, so
the ring-answer path would raise `NameError`. From `8f67608` (2026-10-14).
- Series-3 `5A` 64 KB page-boundary bug (known; surfaces as HTTP 500).
- `POST /device/config` writes a fixed 29-byte `0x82` blob from one 3-11-26
capture, whatever the unit's trigger settings.
- `/device/events` runs a full 5A download per event just to list headers.
- `0x08` is named `read_event_index` in `micromate/`; it is the preferences
block.
## Left open by the phase 1a review (2026-10-21)
Minor findings from the whole-branch review, parked here so they outlive the
plan's scratch ledger. None blocks 1a; the phase each one matters to is named.
- **CORS ordering (1c, if a browser calls SFM directly).** The `/device` guard
middleware is registered after CORS, so it sits outside it: its 409/501
responses carry no `access-control-allow-origin`, and an OPTIONS preflight to
a guarded URL gets the guard's refusal instead of CORS's 200. Register CORS
last, or let OPTIONS through. Terra-View proxies server-side and is not
affected.
- **Legacy handlers take no unit lock (1c / phase 3).** The guard checks for a
held line and then lets the legacy handler run unlocked; a legacy request
admitted just before a Series-4 call-up at the same address can overlap it.
- **Address keys are not normalised.** `tcp:<host>:<port>` is the raw string:
a hostname vs an IP, or `/dev/serial/by-id/...` vs `/dev/ttyACM0`, gets two
locks for one link.
- **A serial-less request to an UNHELD Micromate still runs Series-3 bytes.**
The guard only knows about lines SFM holds. This is the phase-2 opcode
guard's job.
- **`tcp_port` coercion mismatch.** The guard parses with `int()`, pydantic
coerces more loosely (`"9034.0"`), so such a request passes the guard
unchecked. Parse with pydantic's own int coercion, or fail closed.
- **Test gaps.** The middleware wrapper itself is untested (a raw ASGI call
works without httpx); the contract test compares field names of one shared
dataclass, which cannot fail, and does not enforce "a field absent for one
series lives under `detail`".
- **`_ensure_reaper` race.** Two first Series-4 requests at once can start two
reaper threads; harmless because `try_hold` keeps them off each other's units.
- **Held serial lines share `/dev/ttyACM0` silently.** pyserial's open is not
exclusive, so a bench script beside a held line interleaves bytes with the
keep-alive; it looks like a dead unit. Open with `exclusive=True`, or don't
hold serial links.
## Left open by the phase 1b review (2026-10-21)
Parked from the whole-branch review of 1b; none blocks it. The phase each
matters to is named.
- **Retry re-runs a whole download (1c).** The retry-once on a held-line timeout re-runs the full download, roughly doubling time-to-error; narrow it to failures before the first reply.
- **`last_used` after a kept-line error (1c).** It is not refreshed when an op's verdict (404/409) keeps the line, so the idle hang-up comes early.
- **`verified: null` is ambiguous (1c).** It means both "a histogram" (no check exists) and "a waveform whose check could not run".
- **Mic naming and the Series-4 mic decode (1c).** `detail.mic_psi` on Series 3, `detail.mic` on Series 4; Series 4's `0x0C` mic decodes as a denormal (~5e-39) — fix the decode before 1c shows it.
- **500 detail leaks paths (1c, before SFM is reachable beyond Terra-View).** The download handler's 500 detail includes raw exception text, filesystem paths included.
- **Serial as a directory name (1c).** The serial is never checked against `[A-Z0-9]+` before it names a store directory; only the unit can choose it, but the check is cheap.
- **No server-level RADIO RING mid-download test (1c).** Covered structurally (DeviceAccess-level test + the ring transport), not through the handler.
- **Series-3 stored `record_type` (MiniMate bench check).** Rows SFM stores for Series 3 still say "Waveform" for histograms — pre-existing, the same as the legacy `blastware_file` route; fix it with the `0C` decode.
- **A fresh Series-4 download's gaps (1c).** No `sample_rate` is stored, and the sidecar has no vector sum; the DB row has the unit's PVS (overlaid from `0x0C`).
- **Orphan files (SDM).** An event file in the store with no DB row is still overwritten by a download.
- **Same-second collisions (SDM).** Two events of one unit in the same second collide on (serial, timestamp) — a DB-wide dedup property, not 1b's.
- **423 without `Retry-After` (1c).** Add `Retry-After` to the 423 a request gets while a download holds the unit.
- **A lost `0C` during a Series-3 list.** The strict walk raises on a lost `0A`
or `1F`, but a lost `0C` still lists the event with no timestamp and an
`event_id` ending `:-`. Downloading that id skips the stale check and runs the
full `5A`, then refuses to store it (no timestamp means no filename), so it is
wasted transfer, not bad data. Fix: raise on a lost `0C` in strict mode, or
refuse `:-` ids for Series 3.
- **A lost reply on a Series-3 TCP walk re-runs it once** under the adapter's
cold-boot retry before the 504, doubling time-to-error on a bad link.
## Table 2: to be added later (both series)
| area | item |
|---|---|
| infrastructure | async jobs; auth via Terra-View |
| THOR has it, SFM doesn't | clock set; remote sensor check; scheduler; one setup to many units; restart |
| call-home receiver | hold lines open (S4); "already downloaded" tracking; rules by serial prefix (copy events, monitor log, delete, set clock); detect "Monitor While Calling Home" blocking deletes (⚠ one unexplained 21 → 5 count drop in THOR's log); hand off to `/db/import/*` instead of the watchers |
| settings, the no-PC-files way | intended settings per deployment; drift report (intended vs actual); push then verify |
| notifications | email/SMS by event type and PPV (THOR does it; may belong in Terra-View) |
| emergency tools for S4 | if a Micromate ever needs them |
## Parking lot
**Monitor logs.** Its own piece of work, data side as much as device side.
A unit calls in at least once or twice a day. With no events (e.g. waveform
mode, no blast that day) it still delivers a **monitor log**: "monitoring from
X to Y". The watchers (one for BW-ACH / Series 3, one for THOR-ACH / Series 4)
use the newest file per unit, event or `.MLG`, as SFM's "last heard from" age.
They forward waveform and histogram files but **not** monitor logs. To decide:
- Ingest call-in monitor logs into SFM. SFM's DB **already has** a
`monitor_log` table (one row per interval, deduped by serial + start time),
and `minimateplus/blastware_file.py` already parses Series-3 `.MLG`.
Missing: anything that takes `.MLG` in from the watchers, and knowledge of
THOR's Series-4 monitor-log file format.
- A live monitor-log read over a connection (Series 4: `0x0A` exists, no
wrapper or decoder; Series 3 in SFM: none).
- What it is for: proof of coverage ("was it monitoring when they blasted?")
and visible gaps.
- Related fix-list item: `ach_server.py`'s `seen_keys`.
**How SFM handles setup files and schedules.** This phase only reads and
pushes the unit's *active* setup, with no PC-side library (the `.mmb`
same-name/different-contents gotcha). Still to decide, as one question because
the two are coupled:
- The unit stores up to 25 named `.MMB` files. Should SFM manage them (list,
select, rename, delete, push to a named file), or only ever touch the active
one?
- **Schedules name setup files.** A schedule entry switches the unit to a
setup by name, so a schedule is only as reliable as the files it points to.
What if it points to a file that isn't there? That is untested.
- How "intended settings per deployment" (Table 2) fits with files and
schedules.
- Scheduler read/write is mostly mapped (file transfer + `0x47`); **disable has
never been captured**.
**A modem-side agent on the RX55.** AirLink
OS on the RX55 has "Container Applications (Early Adopter)", and Brian already
runs `slmm-proxy` there. A small program owning the unit's serial port could:
- let THOR and SFM share the line
- dial out to SFM, avoiding the IP whitelist
- handle `RADIO RING` locally
- **Brian's hunch:** make RX55s work with Series 3 by driving DTR/DCD itself
Open questions:
- Can a container open the RS-232 port?
- Can it set the control lines?
- How is it deployed to a fleet, and does it Autostart?
- Will a firmware update keep the beta feature?
## Open questions this design leaves for the bench
- The ack for start/stop when the unit is already in that state.
- The offset rule, and whether `0x68`/`0x82` are required, for the setup push.
- Whether the device ever refuses a write while monitoring. Only THOR's policy
has been seen.
- How a failed write is signalled. It has never been observed.
- MiniMate behaviour with a held session (above).
-624
View File
@@ -1,624 +0,0 @@
"""
client.py — high-level API for a live Micromate (Series IV).
Owns the transport, turns raw payloads into models. Read-only, like the layer
below it: nothing here writes, erases, or changes monitoring state.
with MicromateClient(TcpTransport("63.45.161.30", 9034)) as mm:
info = mm.connect()
print(info) # UM12947 MM/ISEE/S/IO blastware fw idle
print(mm.get_state()) # idle 2026-09-25 01:14:05 3.80 V memory 0.4% used
for name in mm.list_setups():
print(name)
The response layout, measured rather than assumed
-------------------------------------------------
**Every response carries an 11-byte prefix, and the content starts at
``data[11]``.** That one rule covers every command.
⚠ **``data[0]`` looks like the content length and is only its low byte.** A
2,092-byte setup block (`SUB 0x1A`) reports 44, and a 1,024-byte download chunk
reports 0. It happens to be right for every response shorter than 256 bytes,
which is most of them — so it reads as a working length field right up until it
silently loses 2,048 bytes. There is no high byte anywhere in the prefix; it is
``length & 0xFF`` and nothing more.
This is the same trap as ``MicromateFrame.probe_length``, in a different place,
and it is now the third time a length in this protocol has been read too narrow.
**Take the content as ``data[11:]`` and let the frame's own length bound it.**
"""
from __future__ import annotations
import datetime
import logging
import math
import os
import struct
from typing import Optional
from minimateplus.transport import BaseTransport
from .models import MicromateDeviceInfo, MicromateEventRef, MicromateSetup, MicromateState
from .protocol import MicromateProtocol, ProtocolError
from .setup_block import decode_setup
log = logging.getLogger(__name__)
# The content of every response begins here; the first 11 bytes are a prefix
# whose only decoded field is an unreliable low-byte length (see module docstring).
CONTENT = 11
# Field offsets, relative to the start of content. Sources are named because
# two of them disagree with docs/micromate_protocol_reference.md.
_STATE_FLAG = 0 # 0x49: 0x00 idle, 0x02 monitoring
# 0x06 storage range. content[0:4] is the event count: 3/3 against the chain
# walk, and THOR's ReadEventRecordCount agrees. content[4:8] is very likely
# the monitor-log count -- graded a strong candidate, not settled, so not exposed.
_SR_EVENT_COUNT = slice(0, 4)
_MS_FLAG = 1 # 0x1C: monitoring flag — test NON-ZERO
_MS_DAY, _MS_MONTH, _MS_YEAR = 2, 3, slice(4, 6)
_MS_UNKNOWN_6 = 6 # ⚠ sub-second tick (~4020/s, step 4, 64 ms wrap) — NOT the hour
_MS_HOUR, _MS_MIN, _MS_SEC = 7, 8, 9
_MS_BATTERY = slice(34, 36) # uint16 BE, volts × 100
_MS_MEM_TOTAL = slice(36, 40) # uint32 BE
_MS_MEM_FREE = slice(40, 44) # uint32 BE
# `SUB 0x0C` record, relative to content. Established against 7 events across
# both firmware lines.
_REC_DAY, _REC_MONTH, _REC_YEAR = 0, 1, slice(2, 4)
_REC_UNKNOWN_4 = 4 # ⚠ same shape as 0x1C's content[6]; undecoded
_REC_HOUR, _REC_MIN, _REC_SEC = 5, 6, 7
_REC_TYPE = 11 # 0x07 waveform, 0x08 histogram
_REC_LOCATION = 12
_REC_SETUP = 34
_REC_SERIAL = 76
_RECORD_TYPES = {0x07: "waveform", 0x08: "histogram"}
# The channel labels the record carries, in the order they appear. The peak
# float sits `label + 6`; the peak vector sum sits 12 bytes BEFORE "Tran".
_REC_CHANNELS = (b"Tran", b"Vert", b"Long", b"Mic")
_REC_PVS_BACK = 12
# A chain walk terminates on an all-zero key. The ceilings below are guards
# against a device cursor that never advances, not fleet limits.
_NULL_KEY = bytes(4)
_MAX_EVENTS = 4096
# A setup-list walk that does not terminate is a bug, not a big fleet. The
# bench unit holds 22 setups; this is a generous ceiling, not a limit.
_MAX_SETUPS = 512
def _content(data: bytes) -> bytes:
"""Strip the 11-byte response prefix."""
return data[CONTENT:] if len(data) > CONTENT else b""
def _cstring(buf: bytes, offset: int = 0) -> str:
"""A null-terminated ASCII run, stripped."""
return buf[offset:].split(b"\x00")[0].decode("ascii", "replace").strip()
class DecodeMismatch(ProtocolError):
"""Our decoded peak disagrees with the one the device computed itself."""
class MicromateClient:
"""High-level read-only client for one Micromate.
Owns the transport, unlike ``MicromateProtocol``, which borrows it.
"""
def __init__(
self,
transport: BaseTransport,
recv_timeout: float = 10.0,
strict_checksums: bool = True,
) -> None:
self._transport = transport
self._proto = MicromateProtocol(
transport, recv_timeout=recv_timeout, strict_checksums=strict_checksums
)
self._firmware_line: Optional[str] = None
self._serial: Optional[str] = None
# ── Lifecycle ─────────────────────────────────────────────────────────────
def open(self) -> None:
self._transport.connect()
def close(self) -> None:
self._transport.disconnect()
def is_open(self) -> bool:
# `is_connected` is a PROPERTY on BaseTransport. Calling it raised
# TypeError on every real transport; only a test double that defined
# it as a method hid that.
return bool(self._transport.is_connected)
def __enter__(self) -> "MicromateClient":
self.open()
return self
def __exit__(self, *_) -> None:
self.close()
@property
def protocol(self) -> MicromateProtocol:
"""The wire layer, for anything this class does not wrap yet."""
return self._proto
# ── Identity ──────────────────────────────────────────────────────────────
def connect(self, *, with_active_setup: bool = True) -> MicromateDeviceInfo:
"""`POLL → SERIAL → state`, plus the active setup name.
⚠ **This is deliberately not Thor's full preamble.** Thor sends
`POLL → SERIAL → 0x49 → POLL` and the client spec said to copy it
verbatim on the grounds that it is known-good. Measuring all 8 captured
sessions showed the only invariant is that a session **opens with
POLL** — the four-command form appears in 3 of 8 and is Thor's
*connection check*, run where it wants to refresh what it displays. The
trailing POLL is a repeat of the first.
So this sends the three reads that actually gather something. Dropping
the fourth is a judgement call on measured evidence, not a proof that
nothing depends on it; if a unit ever refuses the next command after a
cold connect, put it back and say so in the protocol reference.
`SUB 0x01` (device info) is **not** read. Thor never reads it in any
captured session, its field layout is unmapped beyond eight `1.0f`
floats, and `firmware_line` — the one thing we would want from it — comes
free from the flags byte of any response.
"""
poll = self._proto.poll()
self._firmware_line = poll.firmware_line
manufacturer, model = self._parse_poll(poll.data)
serial = _cstring(_content(self._proto.read_serial()))
self._serial = serial
monitoring = self._parse_state(self._proto.read_state())
info = MicromateDeviceInfo(
serial=serial,
manufacturer=manufacturer,
model=model,
firmware_line=poll.firmware_line,
monitoring=monitoring,
)
if with_active_setup:
try:
info.active_setup = self.get_active_setup()
except ProtocolError as e:
# Not worth failing a connect over: a unit with no setup loaded
# is a real state, and the caller can still read everything else.
log.warning("active setup unreadable: %s", e)
log.info("connected: %s", info)
return info
@staticmethod
def _parse_poll(data: bytes) -> tuple[Optional[str], Optional[str]]:
"""Manufacturer and model out of the POLL block.
`Instantel` sits at content[4] and the model at content[26], with 13
binary bytes between them.
⚠ A generic "find the printable runs" scan does **not** work here, which
cost a test failure before it cost anything worse. content[3] is `0x50`
— printable as `P` — sitting immediately before `Instantel`, so a run
scan returns `PInstantel`. Nothing distinguishes a length or tag byte
from text by inspection.
So: the manufacturer comes from a fixed offset, and the model is found by
searching for `MM/`. That anchor is structural rather than positional,
which matters because the model string **differs by firmware line** —
`MM/ISEE/S/IO` on the Blastware build, `MM/ISEE/S` on the Thor build —
and only its tail changes.
"""
c = _content(data)
manufacturer = _cstring(c, 4) or None
idx = c.find(b"MM/")
model = _cstring(c, idx) if idx >= 0 else None
return manufacturer, model
@staticmethod
def _parse_state(data: bytes) -> Optional[bool]:
"""`SUB 0x49` content[0]: 0x00 idle, 0x02 monitoring.
⚠ Tested for non-zero, never against `0x02`. The sibling flag in
`SUB 0x1C` has read both `0x0E` and `0x0C` while monitoring, so this
family of flags is not a stable enum.
"""
c = _content(data)
return bool(c[_STATE_FLAG]) if c else None
# ── State ─────────────────────────────────────────────────────────────────
def get_state(self) -> MicromateState:
"""`SUB 0x1C` — monitoring, device clock, battery, memory.
⚠ Every offset here is **forward from the start of content**, never
backward from the end. Series III reads battery and memory from the end
of this block, and this block is **4 bytes longer on the Thor firmware
line** — applying from-the-end offsets to a `11.0BD` unit yields a
battery voltage of 577.92 V. The four extra bytes are trailing, so
from-the-start offsets hold for both lines.
✅ **Confirmed on `11.0BD` 2026-09-30.** UM20147 read back 3.55 V and
a clock correct to the second over USB, so the from-the-start offsets do
survive the four extra trailing bytes. Had they not, the battery would
have read 577.92 V — which is what makes this cheap to check.
"""
data = self._proto.read_monitor_status()
c = _content(data)
if len(c) < 44:
raise ProtocolError(
f"monitor status content is {len(c)} B, need at least 44"
)
battery = int.from_bytes(c[_MS_BATTERY], "big") / 100.0
return MicromateState(
monitoring=bool(c[_MS_FLAG]),
device_time=self._parse_clock(c),
battery_volts=battery,
memory_total_bytes=int.from_bytes(c[_MS_MEM_TOTAL], "big"),
memory_free_bytes=int.from_bytes(c[_MS_MEM_FREE], "big"),
raw=data,
)
def get_event_count(self) -> int:
"""`SUB 0x06` -- events stored. One read; no chain walk."""
c = _content(self._proto.read_storage_range())
if len(c) < 4:
raise ProtocolError(f"storage range content is {len(c)} B, need at least 4")
return int.from_bytes(c[_SR_EVENT_COUNT], "big")
def read_unsolicited(self) -> bytes:
"""Whatever the unit sent unprompted. **Sends nothing.**
One transport read. Bytes between commands are noise to the protocol
(every request resets the parser), so reading them here takes nothing
the protocol needs. A session calls this while idle to notice
RADIO RING without waiting for its next keep-alive.
"""
return self._transport.read(4096)
@staticmethod
def _parse_clock(c: bytes) -> Optional[datetime.datetime]:
"""The unit's own clock, in its own local time.
⚠ **content[6] is not part of the time.** The layout is day, month,
year, *one unidentified byte*, then h/m/s — so the hour is at content[7].
The protocol reference's `SUB 0x1C` section has this right and names
`data[17]` as unidentified; its one-line summary in the divergences list
("day/month/year/h/m/s at `data[13:21]`") reads as six contiguous fields
and is the version worth not trusting.
Re-measured here across three captures: content[6] read 32, 100 and 116,
none a valid hour, while content[7:10] gave 19:12:25, 19:13:34 and
01:14:05 against capture filenames stamped 19:12:14, 19:12:14 and
01:14:03 — each seconds to a minute after its session opened, which is
what a device clock should do.
content[6] is undecoded and deliberately not exposed.
"""
try:
return datetime.datetime(
year=int.from_bytes(c[_MS_YEAR], "big"),
month=c[_MS_MONTH],
day=c[_MS_DAY],
hour=c[_MS_HOUR],
minute=c[_MS_MIN],
second=c[_MS_SEC],
)
except ValueError as e:
# A unit with a dead clock battery reports an impossible date. That
# is information, not a reason to fail the whole state read.
log.warning("device clock unreadable (%s): %s", e, c[2:10].hex(" "))
return None
# ── Setups ────────────────────────────────────────────────────────────────
def get_active_setup(self) -> str:
"""`SUB 0x41` — the loaded `.MMB` file name, e.g. `TEST1.mmb`."""
return _cstring(_content(self._proto.read_active_setup_name()))
def get_setup(self, *, verify: bool = True) -> MicromateSetup:
"""`SUB 0x1A` — what the unit is set to, decoded. One read.
Raises ``SetupChecksumError`` if the block's CRC fails, unless
``verify=False``. Offsets and what is deliberately not decoded are in
``micromate/setup_block.py``.
⚠ This reads the keypad's EDIT BUFFER: if someone is in the unit's setup
menu, unsaved values come back.
"""
return decode_setup(_content(self._proto.read_compliance_config()), verify=verify)
def list_setups(self) -> list[str]:
"""`0x3F` then `0x40`… — every setup file stored on the unit.
A cursor walk: the device holds the position, so the same `0x40` request
returns the next name. **An empty name terminates the list** — it is
not an error and not a real setup.
Measured on the bench unit: 23 responses, 22 names then the empty one,
`factory.MMB` first through `TEST1.mmb` last.
"""
names: list[str] = []
raw = self._proto.read_first_setup()
for _ in range(_MAX_SETUPS):
name = _cstring(_content(raw))
if not name:
return names
names.append(name)
raw = self._proto.read_next_setup()
raise ProtocolError(
f"setup list did not terminate after {_MAX_SETUPS} entries — the "
f"device cursor is not advancing"
)
# ── Events ────────────────────────────────────────────────────────────────
def serial(self) -> str:
"""The unit's serial, cached from `connect()` or read on demand.
Needed by anything that handles an event, because an event key is
ambiguous without it — see `MicromateEventRef`.
"""
if self._serial is None:
self._serial = _cstring(_content(self._proto.read_serial()))
return self._serial
def list_events(self, *, with_records: bool = True) -> list[MicromateEventRef]:
"""Walk the event chain. `0x93 → 1E`, then `0x93 → 1F` until the sentinel.
THOR sends `0x93` before **every** chain read, and this mirrors that.
The chain ends on an all-zero key.
⚠ `with_records=True` costs **one extra round trip per event** for the
`0x0C` read, and over cellular a round trip is ~0.65 s regardless of
size. On a unit with 40 events that is the difference between ~52 s and
~78 s. Pass False when you only need "what is here and how big" — but
note the **record is where the type and timestamp live**, so without it
`ref.filename` is None and `get_event()` cannot pick a suffix.
⚠ **To download, prefer `iter_events()`.** This walks the whole chain
first; THOR interleaves, downloading each event before advancing.
`0x5A` addresses an event by key, so downloading afterwards *should*
work — but "should" is doing real work in that sentence, and the
interleaved order is the one with captures behind it. See
`iter_events()`.
"""
serial = self.serial()
refs: list[MicromateEventRef] = []
for i in range(_MAX_EVENTS):
self._proto.arm_event()
raw = (self._proto.read_event_first() if i == 0
else self._proto.read_event_next())
c = _content(raw)
if len(c) < 8:
raise ProtocolError(
f"chain entry {i}: {len(c)} B of content, need 8 (key + size)"
)
key, size = c[0:4], int.from_bytes(c[4:8], "big")
if key == _NULL_KEY:
return refs # the sentinel, not an error
ref = MicromateEventRef(index=i, key=key, size=size, serial=serial)
if with_records:
self._read_record_into(ref)
refs.append(ref)
raise ProtocolError(
f"event chain did not terminate after {_MAX_EVENTS} entries — the "
f"device cursor is not advancing"
)
def iter_events(self, *, with_records: bool = True):
"""Walk the chain, yielding each event **at the cursor position THOR uses.**
for ref in mm.iter_events():
if ref.is_histogram:
continue
data = mm.download_event(ref) # ← safe here
Why this exists alongside `list_events()`: THOR's captured order is
0x93 → 1E → 0C → 5A×n → 0x93 → 1F → 0C → 5A×n → …
— it downloads each event *before* advancing the chain. `list_events()`
walks to the end first, which is fine for browsing (the browse walk is
separately attested) but means a later download happens with the device
cursor parked past the event. `0x5A` is key-addressed, so it very
probably does not care; nothing observed says it does, and nothing
observed says it does not.
Downloading inside this loop reproduces THOR's sequence exactly, so it
is the path to use when it matters. ⚠ Do not advance the generator
before finishing with the event it yielded.
"""
serial = self.serial()
for i in range(_MAX_EVENTS):
self._proto.arm_event()
raw = (self._proto.read_event_first() if i == 0
else self._proto.read_event_next())
c = _content(raw)
if len(c) < 8:
raise ProtocolError(
f"chain entry {i}: {len(c)} B of content, need 8 (key + size)"
)
key, size = c[0:4], int.from_bytes(c[4:8], "big")
if key == _NULL_KEY:
return
ref = MicromateEventRef(index=i, key=key, size=size, serial=serial)
if with_records:
self._read_record_into(ref)
yield ref
raise ProtocolError(
f"event chain did not terminate after {_MAX_EVENTS} entries — the "
f"device cursor is not advancing"
)
def _read_record_into(self, ref: MicromateEventRef) -> None:
"""`SUB 0x0C` — 210 B of content: timestamp, type, names, peaks."""
raw = self._proto.read_event_record(ref.key)
c = _content(raw)
if len(c) <= _REC_SERIAL:
raise ProtocolError(f"event record is {len(c)} B, too short to decode")
ref.raw_record = raw
ref.record_type = _RECORD_TYPES.get(c[_REC_TYPE])
if ref.record_type is None:
# Worth saying out loud rather than filing the event as a waveform:
# the suffix decides which codec runs.
log.warning("event %s: unknown record type 0x%02x at content[%d]",
ref.key_hex, c[_REC_TYPE], _REC_TYPE)
try:
ref.timestamp = datetime.datetime(
year=int.from_bytes(c[_REC_YEAR], "big"),
month=c[_REC_MONTH], day=c[_REC_DAY],
hour=c[_REC_HOUR], minute=c[_REC_MIN], second=c[_REC_SEC],
)
except ValueError as e:
log.warning("event %s: bad timestamp (%s): %s",
ref.key_hex, e, c[:8].hex(" "))
ref.sensor_location = _cstring(c, _REC_LOCATION) or None
ref.setup = _cstring(c, _REC_SETUP) or None
# Prefer the record's own serial over the cached one — they have always
# agreed, but the record is the event's own account of where it came from.
if rec_serial := _cstring(c, _REC_SERIAL):
ref.serial = rec_serial
peaks: dict[str, float] = {}
for label in _REC_CHANNELS:
i = c.find(label)
if i < 0 or i + len(label) + 10 > len(c):
continue
peaks[label.decode()] = struct.unpack(
">f", c[i + len(label) + 2: i + len(label) + 6])[0]
ref.peaks_ips = peaks or None
tran = c.find(b"Tran")
if tran >= _REC_PVS_BACK:
ref.peak_vector_sum_ips = struct.unpack(
">f", c[tran - _REC_PVS_BACK: tran - _REC_PVS_BACK + 4])[0]
def download_event(self, ref: MicromateEventRef, *,
chunk_size: Optional[int] = None) -> bytes:
"""The raw `.IDFW`/`.IDFH` bytes, exactly as THOR would have stored them.
Feeds `micromate.idf_file.read_idf_file()` and `/db/import/idf_file`
unchanged — no new codec work is needed for a directly downloaded event.
`chunk_size` defaults to the measured device ceiling (16,384 B), which is
16x THOR's 1024 and therefore ~14x fewer round trips on a large event.
Pass `THOR_CHUNK_SIZE` to reproduce THOR's wire traffic exactly, or a
smaller value on a link where big responses are not surviving.
"""
kw = {} if chunk_size is None else {"chunk_size": chunk_size}
return self._proto.read_event_file(ref.key, ref.size, **kw)
def get_event(self, ref: MicromateEventRef, *, verify: bool = True,
tolerance: float = 0.01, chunk_size: Optional[int] = None):
"""Download and decode one event.
Returns the codec's `IdfReadResult`. Needs `ref.record_type`, since
`read_idf_file()` dispatches on the filename suffix and there is no
filename on the wire — so call `list_events(with_records=True)` first.
⚠ `verify=True` re-computes the **peak vector sum** from the decoded
samples and compares it against the float the *device* put in the `0x0C`
record. Those are two independent computations over the same samples —
the device's from its own firmware, ours from our codec — so a
disagreement means our decode is wrong. Measured agreement on the bench
events is **0.000%**.
This is cheap insurance in a codebase whose decode failures have
historically been *silent*: unhandled block tags shorten a channel and
nothing raises. ⚠ It is a decode-correctness check, **not** a
truncation detector — a channel cut after its peak still yields the
right PVS.
Histograms are not verified: `samples` is empty for them.
"""
return self.fetch_event(ref, verify=verify, tolerance=tolerance,
chunk_size=chunk_size)[1]
def fetch_event(self, ref: MicromateEventRef, *, verify: bool = True,
tolerance: float = 0.01, chunk_size: Optional[int] = None):
"""`get_event()`, returning the raw bytes too: `(blob, result)`.
For a caller that stores the file AND wants the self-check: the bytes go
to the waveform store unchanged, and a DecodeMismatch stops them being
stored at all.
"""
if not ref.record_type:
raise ValueError(
f"event {ref.key_hex}: record_type is unknown, so the codec "
f"cannot be dispatched. Use list_events(with_records=True)."
)
blob = self.download_event(ref, chunk_size=chunk_size)
import tempfile
from .idf_file import read_idf_file
# read_idf_file dispatches on the suffix, so the bytes need a name.
with tempfile.NamedTemporaryFile(suffix=ref.suffix, delete=False) as f:
f.write(blob)
tmp = f.name
try:
result = read_idf_file(tmp)
finally:
os.unlink(tmp)
if verify and not ref.is_histogram:
err = self.decode_error(ref, result)
if err is not None and abs(err) > tolerance:
raise DecodeMismatch(
f"event {ref.uid}: decoded peak vector sum differs from the "
f"device's own by {100 * err:+.3f}% (tolerance "
f"{100 * tolerance:.1f}%) — the decode is suspect, not the "
f"device. Stored {ref.peak_vector_sum_ips:.5f} in/s."
)
if err is not None:
log.debug("event %s: PVS agrees to %+.4f%%", ref.uid, 100 * err)
return blob, result
@staticmethod
def decode_error(ref: MicromateEventRef, result) -> Optional[float]:
"""Relative error between our decoded PVS and the device's stored one.
None when either side is unavailable. Positive means the device's
figure is higher than ours.
"""
from .idf_file import geo_count_to_ips
stored = ref.peak_vector_sum_ips
if not stored or not getattr(result, "samples", None):
return None
ch = {k.lower(): v for k, v in result.samples.items()}
try:
t, v, l = ch["tran"], ch["vert"], ch["long"]
except KeyError:
return None
n = min(len(t), len(v), len(l))
if not n:
return None
pvs = max(
math.sqrt(geo_count_to_ips(t[i]) ** 2
+ geo_count_to_ips(v[i]) ** 2
+ geo_count_to_ips(l[i]) ** 2)
for i in range(n)
)
return (stored - pvs) / pvs if pvs else None
-304
View File
@@ -1,304 +0,0 @@
"""
framing.py — frame codec for the Instantel Micromate (Series IV) wire protocol.
A Micromate answers Series III *command* frames, so the request side looks
familiar. The framing underneath is not the same, and the differences are all
of the kind that produce a silently-ignored frame rather than an error:
Series III response: [DLE 0x10] [STX 0x02] … [chk] [ETX 0x03]
Micromate response: [STX 0x02] … [chk] [ETX 0x03]
^ no leading DLE
That missing byte is why `minimateplus.framing.S3FrameParser` returns *nothing*
on Micromate traffic — it locates frames by scanning for `DLE STX`, which never
occurs. A capture holding 12 acknowledged writes reads as 12 unanswered
requests.
De-stuffed payload layout (both directions):
request response
[0] CMD 0x10 [0] CMD 0x00
[1] flags 0x00 [1] flags 0xC5 / 0x03 ← firmware line
[2] SUB [2] SUB 0xFF − request_SUB
[3] 0x00 [3] PAGE_HI
[4] offset_hi [4] PAGE_LO
[5] offset_lo [5+] data
[6:16] params (10 bytes)
Everything below was established against the 251 request and 251 response
frames in `bridges/captures/9-24-26 - micromate2/` (UM12947, firmware 11.0CB).
Where a rule is asserted, the number of frames it was checked on is given — the
two rules that look like small details cost 26% and 22% of frames respectively
when guessed wrong, so the counts are the point.
"""
from __future__ import annotations
from dataclasses import dataclass
from typing import Optional
# ── Protocol byte constants ───────────────────────────────────────────────────
DLE = 0x10 # Data Link Escape
STX = 0x02 # Start of text — begins a frame
ETX = 0x03 # End of text — ends a frame
ACK = 0x41 # Frame-start marker on the request side
MM_CMD = 0x10 # payload[0] in a request
MM_RSP_CMD = 0x00 # payload[0] in a response
# payload[1] of a response identifies the firmware line it came from.
# ⚠ Two units, one of each — a strong hypothesis, not a proven encoding.
FLAGS_BLASTWARE = 0xC5 # the 11.0CB line (UM12947)
FLAGS_THOR = 0x03 # the 11.0BD line (UM20147)
# ⚠ THE ESCAPE SET. A Micromate escapes exactly these four byte values,
# prefixing each with a DLE — and nothing else. Established by re-stuffing
# every captured frame and comparing to the wire: 251/251 responses and 251/251
# requests reproduce byte-for-byte with this set, and no other candidate set
# reproduces even 200 of either.
#
# The two near-misses are worth naming, because both look plausible:
# * `{0x10}` alone — the Series III rule — reproduces 130/251 responses and
# 177/251 requests.
# * adding ACK (0x41) reproduces only 196/251 responses: a literal 0x41 in
# the data is NOT escaped.
_ESCAPED = frozenset({STX, ETX, 0x04, DLE})
# A response header is 5 bytes; a frame must also carry its checksum.
_MIN_PAYLOAD = 5
_REQUEST_PAYLOAD_SIZE = 16
# ── Stuffing ──────────────────────────────────────────────────────────────────
def stuff(data: bytes) -> bytes:
"""Escape every byte the Micromate escapes: `XX` → `10 XX` for the four."""
out = bytearray()
for b in data:
if b in _ESCAPED:
out.append(DLE)
out.append(b)
return bytes(out)
def unstuff(data: bytes) -> bytes:
"""Reverse `stuff()`: `10 XX` → `XX`, for any XX.
Uniform, with no inner-frame carve-out — which is a real simplification
over Series III, where `DLE+ETX` inside a frame is literal data that must
survive de-stuffing. Since only four byte values are ever escaped, taking
*any* `10 XX` as `XX` is exact rather than merely convenient.
"""
out = bytearray()
i = 0
while i < len(data):
if data[i] == DLE and i + 1 < len(data):
out.append(data[i + 1])
i += 2
else:
out.append(data[i])
i += 1
return bytes(out)
# ── Checksum ──────────────────────────────────────────────────────────────────
def checksum(payload: bytes) -> int:
"""SUM8 of the **de-stuffed** payload, mod 256. 251/251 both directions.
⚠ Do NOT exclude `0x10` bytes from this sum. The DLE-aware checksum that
Series III uses for its `5A` and write frames is the right answer to a
*different* question: it pairs with Series III de-stuffing, which leaves
escaped bytes in the payload as two bytes. De-stuffing uniformly already
removes the DLE, so excluding `0x10` as well subtracts the correction
twice.
That combination — uniform de-stuffing *and* an exclusive sum — is what
`scratch/mm_frame_parse.py` shipped with. It disagrees with the wire on
**55 of 251** captured response frames, all of them frames whose payload
holds a literal `0x10`. The script only ever looked correct because it
accepts a frame that matches *either* rule, so it reported those 55 as
plain SUM8 and never flagged one bad.
"""
return sum(payload) & 0xFF
# ── Request builder ───────────────────────────────────────────────────────────
def build_request(sub: int, offset: int = 0, params: bytes = bytes(10)) -> bytes:
"""Build a host→unit command frame.
⚠ Do **not** substitute `minimateplus.framing.build_bw_frame()` here, even
though the payload layout is identical. That builder escapes only `0x10`,
so it reproduces just **161 of Thor's 218** captured read frames. The 57 it
gets wrong are not edge cases:
* every `SUB 0x5A` bulk download — `offset = 0x0400` puts a literal
`0x04` in `offset_hi`, which must go out as `10 04`
* `SUB 0x47` (scheduler enable), whose params carry a `0x03`
An unescaped `0x03` or `0x04` reads as a frame terminator, so the unit sees
a truncated frame and simply does not answer. That is indistinguishable
from a dead unit, and event download would have hit it on the first try.
With the correct escape set this builder reproduces **218/218**.
Args:
sub: command SUB byte.
offset: uint16 at payload[4:5]. Micromate reads are single-step —
Thor asks for `0xFFFF` and gets the whole block — so this is
usually `0xFFFF`, not Series III's probe-then-data pair.
params: exactly 10 bytes at payload[6:16].
A `0x10` inside `params` is fine and needs no special handling: Thor sends
`SUB 0x5A` with `params = 00 00 10 00 …` and the wire carries `10 10`.
(This was the spec's one open question; five captured frames settle it.)
"""
if len(params) != 10:
raise ValueError(f"params must be exactly 10 bytes, got {len(params)}")
if not 0 <= offset <= 0xFFFF:
raise ValueError(f"offset must fit in uint16, got {offset:#x}")
if not 0 <= sub <= 0xFF:
raise ValueError(f"sub must be a single byte, got {sub:#x}")
payload = bytes([MM_CMD, 0x00, sub, 0x00, (offset >> 8) & 0xFF, offset & 0xFF]) + params
body = payload + bytes([checksum(payload)])
return bytes([ACK, STX]) + stuff(body) + bytes([ETX])
# ── Response frame ────────────────────────────────────────────────────────────
@dataclass
class MicromateFrame:
"""A parsed, de-stuffed unit→host response frame."""
sub: int # response SUB; the request was 0xFF − this
flags: int # payload[1] — 0xC5 Blastware line, 0x03 Thor line
page_hi: int
page_lo: int
data: bytes # payload[5:], checksum stripped
checksum_valid: bool
chk_byte: int = 0 # the checksum byte as received
@property
def request_sub(self) -> int:
"""The SUB this is answering. No known exception to `0xFF − SUB`."""
return 0xFF - self.sub
@property
def page_key(self) -> int:
"""payload[3:5] as a uint16 BE — a page/address on `0x5A` responses."""
return (self.page_hi << 8) | self.page_lo
@property
def firmware_line(self) -> str:
return {FLAGS_BLASTWARE: "blastware", FLAGS_THOR: "thor"}.get(self.flags, "unknown")
@property
def probe_length(self) -> Optional[int]:
"""Data length declared by a **probe** response: uint16 BE at data[3:5].
⚠ Only meaningful in the reply to an `offset = 0` probe. Series III
hardcodes a `DATA_LENGTHS` table; a Micromate will tell you instead,
which already caught one divergence (call-home config is `0x7E`, where
Series III has `0x7C`).
⚠ It is a **uint16 BE**, not a byte. Read as `data[3]` alone it is
right only while the high byte is zero, and wrong by 47x for
`SUB 0x1A`: a true `0x082C` (2092) reads as 44.
Returns None on a frame too short to hold the field. Note this reads
as 0 on the single-step reads Thor actually uses — those are not probes,
and `page_key` is the meaningful field there.
"""
if len(self.data) < 5:
return None
return (self.data[3] << 8) | self.data[4]
# ── Streaming parser ──────────────────────────────────────────────────────────
class MicromateFrameParser:
"""Incremental parser for unit→host frames. Mirrors `S3FrameParser`.
Feed bytes with `feed()`; completed frames are returned and also collected
in `.frames`.
IDLE — scanning for a bare STX
IN_FRAME — collecting; bare ETX terminates
AFTER_DLE — the next byte is literal, whatever it is
Request frames are rejected rather than parsed: a frame whose `payload[0]`
is not `0x00` is dropped, so feeding a bidirectional capture yields only
the responses.
"""
_IDLE, _IN_FRAME, _AFTER_DLE = 0, 1, 2
def __init__(self) -> None:
self._state = self._IDLE
self._body = bytearray()
self.frames: list[MicromateFrame] = []
# Distinguishes "no bytes at all" from "bytes but no complete frame" on
# a timeout. That distinction earned its keep during the Series III
# work and costs one integer here.
self.bytes_fed: int = 0
def reset(self) -> None:
self._state = self._IDLE
self._body.clear()
self.bytes_fed = 0
def feed(self, data: bytes) -> list[MicromateFrame]:
self.bytes_fed += len(data)
completed: list[MicromateFrame] = []
for b in data:
frame = self._step(b)
if frame is not None:
completed.append(frame)
self.frames.append(frame)
return completed
def _step(self, b: int) -> Optional[MicromateFrame]:
if self._state == self._IDLE:
if b == STX:
self._body.clear()
self._state = self._IN_FRAME
# Boot strings, modem RING/CONNECT chatter and stray ACKs land here
# and are discarded.
elif self._state == self._IN_FRAME:
if b == DLE:
self._state = self._AFTER_DLE
elif b == ETX:
self._state = self._IDLE
return self._finalise()
else:
self._body.append(b)
elif self._state == self._AFTER_DLE:
# Uniform rule: the escaped byte is itself, including 0x03.
self._body.append(b)
self._state = self._IN_FRAME
return None
def _finalise(self) -> Optional[MicromateFrame]:
body = bytes(self._body)
if len(body) < _MIN_PAYLOAD + 1:
return None
payload, chk_received = body[:-1], body[-1]
if payload[0] != MM_RSP_CMD:
return None # a request frame, or garbage that framed by accident
return MicromateFrame(
sub = payload[2],
flags = payload[1],
page_hi = payload[3],
page_lo = payload[4],
data = payload[5:],
checksum_valid = (chk_received == checksum(payload)),
chk_byte = chk_received,
)
+44 -225
View File
@@ -47,24 +47,19 @@ from dataclasses import dataclass
from pathlib import Path
from typing import Optional, Union
# Thor IDFW bodies use the series-3 record-chain decoder.
# Thor IDFW bodies are pinned to the SUPERSEDED tag-dispatch decoder.
#
# This was previously pinned to the SUPERSEDED tag-dispatch walker
# (`decode_waveform_legacy`) on the stated grounds that "Thor has no ASCII
# ground truth in the corpus and its geo scaling is separately suspect".
# Both premises were false: Thor writes a per-sample CSV export next to every
# binary (see scratch/verify_thor_against_csv.py), and the scaling is now
# resolved (see _GEO_LSB_IPS). Measured against that ground truth on
# 2026-09-10, the record chain beats the legacy walker outright:
#
# channel truncation 55/153 files -> 3/153
# files exact 98/153 -> 150/153
# per-sample exact 99.781% -> 99.854%
#
# The legacy walker stops at the first unrecognised tag and returns whatever
# channels it had, so its failure mode is silent short channels rather than an
# error. Do not re-pin it.
from minimateplus.waveform_codec import _MODES, decode_waveform_v2, is_record
# _find_waveform_body_offset() trial-decodes every candidate offset and keeps
# whichever yields the most samples. The series-3 record-chain decoder
# correctly returns None where the legacy walker returned garbage, which
# changes that heuristic's winner on 33 of 577 files. The net effect measured
# 2026-08-25 was positive (all-channels-equal 8/577 -> 506/577, mean abs PPV
# error 0.228 -> 0.173 in/s) but Thor has no ASCII ground truth in the corpus
# and its geo scaling is separately suspect, so the switch is deferred until
# the body-offset search is reworked to use the record chain directly.
from minimateplus.waveform_codec import (
decode_waveform_legacy as decode_waveform_v2,
)
from .models import IdfEvent, IdfPeaks, IdfReport
@@ -94,70 +89,23 @@ _BODY_MAGIC = b"\x00\x02\x00"
# fixed-header region where the same magic legitimately appears inside
# channel-test records and the compliance block (offsets 0x015d, 0x091c,
# 0x0ae2, 0x0d30 in observed events).
# Lowered from 0x0E00 to 0x0C00 (2026-09-10). Three-channel events -- mic
# disabled -- have a shorter fixed header and put their record chain head at
# 0x0dba, below the old floor. The head was therefore invisible to the scan,
# which fell through to the *Vert* segment-0 record and decoded a body shifted
# one position around the channel rotation. 46 of 139 files in the
# 9-10-26-csv-req corpus were affected; all 46 became per-sample exact once
# the head was reachable. The floor still skips the fixed-header region,
# where `is_record()` can match channel-test records (0x015d, 0x091c, 0x0ae2).
_BODY_SCAN_FLOOR = 0x0C00
_BODY_SCAN_FLOOR = 0x0E00
# Cap on trial decodes per file. Chain-head detection normally yields one
# or two candidates; the cap only bounds the worst case on a corrupt file.
_MAX_BODY_CANDIDATES = 16
# Geophone count → in/s.
#
# The old value 0.0003 was read off the smallest non-zero sample in the
# sidecar corpus, but that sample is Thor's *4-decimal display rounding* of
# the true LSB, not the LSB itself. It read every series-4 geophone sample
# 3.3% low. The quantisation ladder gives it away: counts 1..6 export as
# 0.0003, 0.0006, 0.0009, 0.0012, 0.0016, 0.0019 — an LSB of exactly 0.0003
# would end 0.0015, 0.0018.
#
# The value below maximises exact 4-dp agreement over 1,046,016 paired
# samples (454 channel-events, 2 units) at 99.854%, versus 50.7% for 0.0003.
# It is a global constant, not a per-unit calibration: all 8 UM units in the
# production store independently agree to within ±0.07% on their
# device-reported PPV. 1/LSB = 3222.6 counts per in/s.
#
# The value is pinned, not guessed. Each exported sample constrains the LSB
# to the window that rounds to the printed 4-dp figure; intersecting 991,415
# such constraints (clean channel-events only) gives
#
# LSB in [0.000310307933, 0.000310308057] width 1.2e-10
#
# 0.000310308 sits at the centre of that window. Equivalent full scale is
# 10.0 in/s / 0.000310308 = 32226.05 counts.
#
# Corroboration from the device: an IDFH interval that never recorded keeps
# its min/max accumulator at its ±full-scale seed, and that seed is
# (min=+32226, max=-32226) — the same magnitude, independently. Note the
# tempting closed form 10.0/32226 is very slightly WRONG: it lands 4.5e-10
# above the feasible window and loses 78 boundary samples to the literal
# value while never winning one. Series-3 uses 32000 counts for the same
# 10.0 in/s, so the two generations do NOT share a scale.
#
# Ground truth + harness: scratch/verify_thor_against_csv.py
_GEO_LSB_IPS = 0.000310308
# Geophone count → in/s, derived from sidecar ground truth: the smallest
# non-zero sample in 1,014-file corpus is 0.0003 in/s.
_GEO_LSB_IPS = 0.0003
# Microphone count → psi, derived from sidecar regression on 50 sample
# pairs from UM11719_20231219162723.IDFW (mic-heavy event).
_MIC_LSB_PSI = 2.14e-6
# IDFH histogram constants.
# Bytes per interval record = 16 per channel + an 8-byte tail, so a
# 4-channel unit uses 72 and a mic-disabled 3-channel unit uses 56. It is
# NOT a constant: derive it per segment from the interval counter (see
# decode_idfh_body). This value survives only as the 4-channel default.
_IDFH_INTERVAL_SIZE = 72 # bytes per per-interval record (4 channels)
_IDFH_CHANNEL_BLOCK = 16 # bytes per channel inside an interval record
_IDFH_INTERVAL_TAIL = 8 # bytes after the per-channel blocks
_IDFH_INTERVAL_SIZE = 72 # bytes per per-interval record
_IDFH_SEGMENT_HEADER = 10 # bytes: [len_be 2B][0a 00 00 00 4B][00 NN 2B][05 3f 2B]
_IDFH_SEGMENT_TAIL = 2 # bytes after the interval data block, before next marker
_IDFH_HALFP_FREQ_NUM = 512.0 # freq_hz = NUM / halfp; halfp ≤ 5 means ">100 Hz" sentinel
_IDFH_GEO_FULL_SCALE = 10.0 # in/s — Normal range
_IDFH_INT16_FS = 32768.0
_IDFH_CHANNELS = ("Tran", "Vert", "Long", "MicL")
@@ -275,67 +223,26 @@ def _find_waveform_body_offset(buf: bytes) -> Optional[int]:
"""
if len(buf) < _BODY_SCAN_FLOOR + 8:
return None
# 1. Locate every plausible per-channel record header. A header carries
# [len 2B][channel_id][00][00] at +2..+6, so anchor the search on the
# three-byte ``<cid> 00 00`` signature and validate with is_record().
# Scanning candidate *preambles* instead is not viable: MODE_RAW16 is
# ``00 00``, so every run of three zero bytes would look like a body
# start and each would cost a full trial decode (~0.5 s/file measured).
floor = max(0, _BODY_SCAN_FLOOR - 7)
starts: list = []
for cid in (0x46, 0x47, 0x48, 0x49):
sig = bytes((cid, 0x00, 0x00))
i = floor
while True:
j = buf.find(sig, i)
if j < 0:
break
i = j + 1
q = j - 4
if q >= floor and is_record(buf, q):
starts.append(q)
if not starts:
return None
starts.sort()
# 2. A body begins at the head of a record chain -- a record that no other
# record's length field points at. The head's own payload is the
# implicit segment-0 Tran record, and the body offset is head + 7 (past
# [len 2B][cid][00][00][seg]) so that body[1:3] lands on the mode.
ends = {q + 2 + int.from_bytes(buf[q + 2 : q + 4], "big") for q in starts}
heads = [q for q in starts if q not in ends] or starts[:1]
# 3. Trial-decode each head and keep the best. Prefer a candidate where
# all four channels come out the same length: scoring on raw sample
# count alone picks false positives sitting *inside* a record header,
# which decode a plausible-looking but rotation-shifted body that
# silently drops each channel's segment 0.
best = None
best_off = None
for head in heads[:_MAX_BODY_CANDIDATES]:
j = head + 7
if j + 3 > len(buf) or (buf[j + 1], buf[j + 2]) not in _MODES:
continue
best: Optional[tuple[int, int]] = None # (total_samples, offset)
i = _BODY_SCAN_FLOOR
while True:
j = buf.find(_BODY_MAGIC, i)
if j < 0:
break
i = j + 1
try:
decoded = decode_waveform_v2(buf[j:])
except Exception:
continue
if not decoded:
continue
lengths = [len(v) for v in decoded.values() if v]
total = sum(len(v) for v in decoded.values())
# A "real" body has more than just the 2-sample preamble.
if total <= 2:
continue
# >= 3 rather than == 4: a mic-disabled event has only the three geo
# channels, and demanding four made `equal` permanently False for
# them, leaving the pick to raw sample count alone.
equal = len(lengths) >= 3 and len(set(lengths)) == 1
score = (equal, total)
if best is None or score > best:
best, best_off = score, j
return best_off
if best is None or total > best[0]:
best = (total, j)
return best[1] if best else None
def _decode_waveform_samples(buf: bytes) -> Optional[dict]:
@@ -392,12 +299,6 @@ class IdfhInterval:
micl_min: int
micl_max: int
micl_halfp: int
# 4 on a normal unit; 3 when the microphone is disabled, in which case the
# micl_* fields are absent from the record and read as zero.
n_channels: int = 4
def has_channel(self, channel: str) -> bool:
return channel != "MicL" or self.n_channels >= 4
def peak_count(self, channel: str) -> int:
mn = getattr(self, f"{channel.lower()}_min")
@@ -406,11 +307,7 @@ class IdfhInterval:
def peak_ips(self, channel: str) -> float:
"""Convert peak count to in/s (geo channels only)."""
# Same geo LSB as the waveform path — verified independently against
# the IDFH exports: as peak magnitude rises (and 4-dp quantisation
# noise falls) the implied LSB converges on 0.0003103, matching
# _GEO_LSB_IPS. The old 10.0/32768 read histogram peaks 1.7% low.
return self.peak_count(channel) * _GEO_LSB_IPS
return self.peak_count(channel) / _IDFH_INT16_FS * _IDFH_GEO_FULL_SCALE
def freq_hz(self, channel: str) -> Optional[float]:
halfp = getattr(self, f"{channel.lower()}_halfp")
@@ -419,46 +316,11 @@ class IdfhInterval:
return _IDFH_HALFP_FREQ_NUM / halfp
def _is_unwritten_interval(interval: "IdfhInterval") -> bool:
"""True for an interval slot the device reserved but never wrote.
Thor seeds each interval's per-channel accumulators at ``min = +full
scale`` and ``max = -full scale`` and then narrows them as samples
arrive. A slot that never recorded keeps that seed, so ``min > max`` —
impossible for real data. Such a record decodes to a full-scale
10.0 in/s peak on every channel and, being a max-over-intervals, poisons
the whole file's PPV.
Rare but real: exactly 1 of 497,611 corpus intervals, and it inflated
that file's Long PPV from 0.0081 to 10.0 in/s. The inversion is always
all-or-nothing across channels (0 partial cases in the corpus), so
requiring every channel to be inverted keeps this from ever firing on
genuine data.
"""
pairs = [
(interval.tran_min, interval.tran_max),
(interval.vert_min, interval.vert_max),
(interval.long_min, interval.long_max),
]
if interval.has_channel("MicL"):
pairs.append((interval.micl_min, interval.micl_max))
return all(mn > mx for mn, mx in pairs)
def _decode_idfh_interval(buf72: bytes, offset: int,
n_channels: int = 4) -> IdfhInterval:
"""Decode one interval record into per-channel min/max/halfp.
The record is ``n_channels`` × 16-byte blocks plus an 8-byte tail, so it
is 72 bytes on a normal unit and 56 when the microphone is disabled.
Missing channels read as zero.
"""
def _decode_idfh_interval(buf72: bytes, offset: int) -> IdfhInterval:
"""Decode one 72-byte interval record into per-channel min/max/halfp."""
import struct
fields = []
for i in range(4):
if i >= n_channels:
fields.extend([0, 0, 0])
continue
block = buf72[i * 16 : (i + 1) * 16]
mn = struct.unpack_from(">h", block, 0)[0]
mx = struct.unpack_from(">h", block, 2)[0]
@@ -474,7 +336,6 @@ def _decode_idfh_interval(buf72: bytes, offset: int,
vert_min=fields[3], vert_max=fields[4], vert_halfp=fields[5],
long_min=fields[6], long_max=fields[7], long_halfp=fields[8],
micl_min=fields[9], micl_max=fields[10], micl_halfp=fields[11],
n_channels=n_channels,
)
@@ -482,73 +343,36 @@ def decode_idfh_body(buf: bytes) -> list:
"""Walk an IDFH file and decode every interval record.
The body has one or more segments; each segment header is 12 bytes:
``[length_be 2B][0a 00 00 00][counter_be 2B][05 3f]`` where ``length``
``[length_be 2B][0a 00 00 00][00 NN_counter][05 3f]`` where ``length``
is bytes from the magic through the end of the interval block
(= 10 + 72 × n_intervals). Segments are separated by a 2-byte tail
+ next-segment 2-byte prefix (the bytes before the next length field).
``counter`` is a **uint16 BE cumulative interval index** — the 0-based
index of the LAST interval in this segment. Segments carry 10
intervals each, so it runs 9, 19, 29, ... across the file.
⚠ This validator used to require ``buf[j + 4] == 0x00``, i.e. that the
counter's high byte was zero. That silently capped every histogram at
**250 intervals**: the moment the cumulative counter passed 255 the high
byte went non-zero and every later segment was rejected, so any
monitoring run longer than ~4 hours lost its tail — frequently the part
holding the event peak, which is why those files' PPV read low. 540 of
858 corpus files were affected. Do not reinstate that check.
Confirmed against the 859-file corpus (181,071 intervals decoded; 1
failure is the sig-B BE9439 file).
"""
intervals: list = []
i = 0
prev_counter = -1 # so the first segment's n = counter + 1
while True:
j = buf.find(b"\x0a\x00\x00\x00", i)
if j < 0 or j < 2:
break
# Validate: [length_be][0a 00 00 00][counter_be][05 3f]. The counter
# is deliberately NOT constrained — see the note above.
if buf[j + 6 : j + 8] != b"\x05\x3f":
# Validate: [length_be][0a 00 00 00][00 NN][05 3f]
if buf[j + 4] != 0x00 or buf[j + 6 : j + 8] != b"\x05\x3f":
i = j + 1
continue
length = int.from_bytes(buf[j - 2 : j], "big")
counter = int.from_bytes(buf[j + 4 : j + 6], "big")
header_start = j - 2
if length < _IDFH_SEGMENT_HEADER or header_start + length > len(buf):
# Truncated / bogus length — not a real segment header.
i = j + 1
continue
# The counter is the cumulative index of this segment's LAST interval,
# so the interval count is its delta from the previous segment. That
# gives the record stride, which is NOT fixed: 16 bytes per channel
# plus an 8-byte tail, so 72 for a 4-channel unit and 56 for a
# mic-disabled 3-channel one. Assuming 72 unconditionally made every
# 3-channel histogram read 7 intervals per 10-interval segment,
# walking off alignment into garbage that decoded as ~10 in/s peaks.
n = counter - prev_counter
n = (length - _IDFH_SEGMENT_HEADER) // _IDFH_INTERVAL_SIZE
if n <= 0:
i = j + 1
continue
stride = (length - _IDFH_SEGMENT_HEADER) // n
n_channels, remainder = divmod(stride - _IDFH_INTERVAL_TAIL,
_IDFH_CHANNEL_BLOCK)
if remainder or not (1 <= n_channels <= 4):
i = j + 1
continue
header_start = j - 2
interval_start = header_start + _IDFH_SEGMENT_HEADER
for k in range(n):
off = interval_start + k * stride
if off + stride > len(buf):
off = interval_start + k * _IDFH_INTERVAL_SIZE
if off + _IDFH_INTERVAL_SIZE > len(buf):
break
chunk = buf[off : off + stride]
interval = _decode_idfh_interval(chunk, off, n_channels)
if _is_unwritten_interval(interval):
# Reserved-but-never-recorded slot: the min/max accumulators
# still hold their ±full-scale seed. Counting it would
# fabricate a 10.0 in/s peak on every channel.
continue
intervals.append(interval)
prev_counter = counter
chunk = buf[off : off + _IDFH_INTERVAL_SIZE]
intervals.append(_decode_idfh_interval(chunk, off))
# Advance past this segment + the 2-byte tail.
i = header_start + length + _IDFH_SEGMENT_TAIL
return intervals
@@ -628,12 +452,7 @@ def read_idf_file(
peak_long = max((iv.peak_ips("Long") for iv in intervals), default=0.0)
# Mic peak in psi — Thor stores per-interval mic ADC counts in the
# binary; convert the max count to psi via the per-count factor.
# Skip on a mic-disabled (3-channel) unit: those records carry no mic
# block at all, so peak_count("MicL") would report a synthetic zero.
mic_peak_count = max(
(iv.peak_count("MicL") for iv in intervals if iv.has_channel("MicL")),
default=0,
)
mic_peak_count = max((iv.peak_count("MicL") for iv in intervals), default=0)
mic_peak_psi = mic_count_to_psi(mic_peak_count) if mic_peak_count else None
rep = IdfReport(
serial_number=md.serial,
-231
View File
@@ -22,7 +22,6 @@ shrink or disappear.
from __future__ import annotations
import datetime
import math
from dataclasses import dataclass, field
from typing import Any, Dict, Optional, Tuple
@@ -397,233 +396,3 @@ class IdfEvent:
)
ev._waveform_key = waveform_key
return ev
# ── Live-device models (2026-09-27) ───────────────────────────────────────────
#
# These describe what a unit reports over the wire, not what Thor wrote to a
# file. Everything above this line came out of Thor's exports; everything below
# came out of Thor's *traffic*. Field offsets are recorded in
# ``micromate/client.py`` next to the code that reads them.
@dataclass
class MicromateDeviceInfo:
"""Identity gathered by ``MicromateClient.connect()``.
Sourced from three reads:
``0x5B`` POLL → manufacturer, model
``0x15`` SERIAL → serial
``0x49`` STATE → monitoring
plus ``firmware_line``, which comes free from the flags byte of any
response and needs no read of its own.
"""
serial: str
manufacturer: Optional[str] = None # "Instantel"
model: Optional[str] = None # "MM/ISEE/S/IO" (CB) / "MM/ISEE/S" (BD)
firmware_line: Optional[str] = None # "blastware" | "thor" | "unknown"
monitoring: Optional[bool] = None
active_setup: Optional[str] = None # e.g. "TEST1.mmb"
def __str__(self) -> str:
bits = [self.serial]
if self.model:
bits.append(self.model)
if self.firmware_line:
bits.append(f"{self.firmware_line} fw")
if self.monitoring is not None:
bits.append("MONITORING" if self.monitoring else "idle")
if self.active_setup:
bits.append(f"setup={self.active_setup}")
return " ".join(bits)
@dataclass
class MicromateState:
"""A unit's live state, from ``SUB 0x1C``.
``device_time`` is the unit's own clock, in its own local timezone — it is
NOT converted. Nothing else this protocol exposes reports the unit's time,
which makes it the only way to detect a drifted clock before it lands in
event timestamps.
"""
monitoring: bool
device_time: Optional[datetime.datetime] = None
battery_volts: Optional[float] = None
memory_total_bytes: Optional[int] = None
memory_free_bytes: Optional[int] = None
raw: Optional[bytes] = field(default=None, repr=False)
@property
def memory_used_bytes(self) -> Optional[int]:
if self.memory_total_bytes is None or self.memory_free_bytes is None:
return None
return self.memory_total_bytes - self.memory_free_bytes
@property
def memory_used_fraction(self) -> Optional[float]:
used = self.memory_used_bytes
if used is None or not self.memory_total_bytes:
return None
return used / self.memory_total_bytes
def __str__(self) -> str:
bits = ["MONITORING" if self.monitoring else "idle"]
if self.device_time:
bits.append(self.device_time.strftime("%Y-%m-%d %H:%M:%S"))
if self.battery_volts is not None:
bits.append(f"{self.battery_volts:.2f} V")
frac = self.memory_used_fraction
if frac is not None:
bits.append(f"memory {frac * 100:.1f}% used")
return " ".join(bits)
_RECORD_MODES = {0x01: "Waveform", 0x02: "Waveform Manual", 0x03: "Histogram", 0x04: "Histogram Combo"}
# The unit's OWN conversion constants, identified bit-exactly from what it
# stored for keypad entries (2026-10-19). Not the textbook 3.28084 / 2.20462:
# convert back with these, or 45 lb entered on the unit reads as 44.89 lb.
_FT_PER_M = 3.2808
_LB_PER_KG = 2.21
_PA_PER_PSI = 6894.757
_P_REF_PA = 20e-6 # dB re 20 µPa
@dataclass
class MicromateSetup:
"""A unit's active setup, from ``SUB 0x1A`` — see ``micromate/setup_block.py``.
**Measured fields only.** Each was located by changing that one setting on a
unit's keypad and watching the bytes; anything graded inferred or unknown in
the protocol reference is left in ``raw`` rather than guessed at here.
⚠ This is what the unit is set to *right now* — including unsaved edits if
someone is in its setup menu, because ``0x1A`` reads the keypad's edit
buffer. Values are in the units the unit stores, whatever it displays:
in/s, psi, metres, kilograms.
"""
name: str # ⚠ ".MMB" after a keypad save, ".mmb" after a load
record_mode: int # see record_mode_name
sample_rate: int # samples per second
histogram_interval_s: int
pretrigger_s: float # positive; the unit stores it negative
auto_record_stop: bool # False = Fixed record time
record_time_s: float
auto_stop_after_s: int # quiet time before an Auto stop
geophones_active: bool
mic_active: bool
trigger_on_geophones: bool
trigger_on_mic: bool
geo_trigger_ips: Tuple[float, float, float] # Tran, Vert, Long
mic_type: str # "linear" | "sound_level" | "unknown (<code>)"
mic_trigger_psi: Optional[float] # linear mic only; SLM units not measured
job_number_enabled: bool
job_number: int # kept while switched off
scaled_distance_enabled: bool
distance_m: float
charge_weight_kg: float
notes: Dict[str, str] # label -> value, in the unit's order
raw: bytes = field(default=b"", repr=False) # the 2,092-byte content
@property
def record_mode_name(self) -> str:
return _RECORD_MODES.get(self.record_mode, f"unknown (0x{self.record_mode:02x})")
@property
def mic_trigger_db(self) -> Optional[float]:
"""dB re 20 µPa. Matches the unit's screen to ±0.001 dB on 131 and 140."""
if not self.mic_trigger_psi:
return None
return 20.0 * math.log10(self.mic_trigger_psi * _PA_PER_PSI / _P_REF_PA)
@property
def distance_ft(self) -> float:
return self.distance_m * _FT_PER_M
@property
def charge_weight_lb(self) -> float:
return self.charge_weight_kg * _LB_PER_KG
@property
def scaled_distance(self) -> Optional[float]:
"""ft / √lb, as the unit computes it for display. It is not stored."""
if self.charge_weight_kg <= 0:
return None
return self.distance_ft / math.sqrt(self.charge_weight_lb)
@dataclass
class MicromateEventRef:
"""One entry in a unit's event chain, from `1E`/`1F` and optionally `0x0C`.
⚠ **`key` is NOT unique across units.** The event counter starts from the
same value on every Micromate — UM12947 and UM20147 both have an event
`055d4a81`, with different sizes and different contents. Use `uid`, or key
on `(serial, key_hex)`, for anything that stores or deduplicates. A store
keyed on the event key alone silently treats one unit's event as a duplicate
of another's, and nothing raises.
"""
index: int
key: bytes # 4-byte event key from the chain walk
size: int # bytes the device will send for this event
serial: Optional[str] = None # the unit, because `key` alone is ambiguous
# From `SUB 0x0C` — one extra round trip per event, so optional.
record_type: Optional[str] = None # "waveform" | "histogram"
timestamp: Optional[datetime.datetime] = None
setup: Optional[str] = None # setup file name, no extension
sensor_location: Optional[str] = None
peak_vector_sum_ips: Optional[float] = None # per-sample PVS, device-computed
peaks_ips: Optional[Dict[str, float]] = None # {"Tran": …, "Vert": …, …}
raw_record: Optional[bytes] = field(default=None, repr=False)
@property
def key_hex(self) -> str:
return self.key.hex()
@property
def uid(self) -> str:
"""`SERIAL:key` — safe to use as a primary key. See the class note."""
return f"{self.serial or '?'}:{self.key_hex}"
@property
def is_histogram(self) -> Optional[bool]:
if self.record_type is None:
return None
return self.record_type == "histogram"
@property
def suffix(self) -> Optional[str]:
return {"waveform": ".IDFW", "histogram": ".IDFH"}.get(self.record_type or "")
@property
def filename(self) -> Optional[str]:
"""The name THOR would have given this event.
`<serial>_<YYYYMMDDHHMMSS>.IDF{W,H}` — e.g.
`UM12947_20260923163319.IDFW`. Verified against the production store
for all five bench events.
⚠ The type comes from the **protocol**, not the payload, so it has to be
carried here from the `0x0C` read. Returns None without it: guessing
the suffix would file a histogram as a waveform, and `read_idf_file()`
dispatches on exactly that.
"""
if not (self.serial and self.timestamp and self.suffix):
return None
return f"{self.serial}_{self.timestamp:%Y%m%d%H%M%S}{self.suffix}"
def __str__(self) -> str:
bits = [self.uid, f"{self.size} B"]
if self.record_type:
bits.append(self.record_type)
if self.timestamp:
bits.append(self.timestamp.strftime("%Y-%m-%d %H:%M:%S"))
if self.peak_vector_sum_ips is not None:
bits.append(f"PVS {self.peak_vector_sum_ips:.4f} in/s")
return " ".join(bits)
-565
View File
@@ -1,565 +0,0 @@
"""
protocol.py — one method per Micromate (Series IV) wire command.
Returns raw payload bytes. Interpretation belongs in ``client.py``; this layer
knows frames, offsets and sequencing, and nothing about what a field means.
Scope: **reads only.** Nothing here writes, erases, or changes monitoring
state. That is deliberate and worth keeping — no command has ever been
originated against a unit by this project; every write in
``docs/micromate_protocol_reference.md`` was performed by THOR while we
recorded. The first thing this codebase ever sends to a customer's instrument
should be a decision someone made on purpose, not a side effect of a client
that grew a method.
Every offset and params layout below was read off THOR's own frames in
``bridges/captures/9-24-26 - micromate2/`` rather than taken from the spec
table, because the same exercise during the framing work found three of that
table's rules wrong. It found three more here:
* ``0x0A`` is the **monitor-log walk** — the same request repeated, the
device advancing its own cursor, terminated by a short response — not the
keyed "event header, 30 B list record" the spec describes.
* ``0x1E``/``0x1F`` carry **token 0xFE** at ``params[7]``. The protocol
reference documents all-zero params for the browse walk; that was our own
probing, and THOR does not do it that way.
* There is **no fixed preamble**. Sessions open with ``POLL`` and go
straight to the operation. ``POLL → SERIAL → 0x49 → POLL`` appears in 3 of
8 captured sessions and is THOR's *connection check*, not a handshake.
And one useful negative: **no ``SESSION_RESET`` (``41 03``).** Series III
needs that 2-byte signal to wake a monitoring unit or it will not answer POLL
over TCP. THOR never sends it — 0 occurrences across all 8 sessions, including
40 frames exchanged with a unit that *was* monitoring.
"""
from __future__ import annotations
import logging
import math
import struct
import time
from typing import Optional
from minimateplus.transport import BaseTransport
from .framing import MicromateFrame, MicromateFrameParser, build_request
log = logging.getLogger(__name__)
DEFAULT_RECV_TIMEOUT = 10.0
# An acknowledgement carries an 11-byte data section and nothing else. It is
# also how the monitor-log walk says "no more records".
ACK_DATA_LEN = 11
# ── Command SUBs ──────────────────────────────────────────────────────────────
SUB_DEVICE_INFO = 0x01
SUB_STORAGE_RANGE = 0x06
SUB_EVENT_INDEX = 0x08
SUB_MONITOR_LOG = 0x0A
SUB_EVENT_RECORD = 0x0C
SUB_SERIAL = 0x15
SUB_COMPLIANCE_CONFIG = 0x1A
SUB_MONITOR_STATUS = 0x1C
SUB_EVENT_FIRST = 0x1E
SUB_EVENT_NEXT = 0x1F
SUB_CALL_HOME_CONFIG = 0x2C
SUB_TRIGGER_CONFIG = 0x2E
SUB_SETUP_FIRST = 0x3F
SUB_SETUP_NEXT = 0x40
SUB_SETUP_ACTIVE = 0x41
SUB_STATE = 0x49
SUB_BULK_DOWNLOAD = 0x5A
SUB_POLL = 0x5B
SUB_ARM_EVENT = 0x93
# ⚠ Reads are SINGLE-STEP. Series III probes at offset 0 to learn the length,
# then reads again at that length; a Micromate returns the whole block when
# asked for 0xFFFF. THOR never probes, which is why `MicromateFrame.probe_length`
# reads 0 on live traffic.
READ_ALL = 0xFFFF
# The two commands that do NOT use READ_ALL, and the data length each returned
# on UM12947 (firmware 11.0CB).
_OFFSETS = {
SUB_POLL: 0x0030, # 59 B — the one offset THOR treats as a constant
SUB_SERIAL: 0x000A, # 21 B
}
# Data-section lengths observed, for orientation only — deliberately NOT
# asserted. `SUB 0x1C` is 4 bytes longer on the Thor firmware line (0x30 vs
# 0x2C declared), so a length check here would fire spuriously on half the
# fleet. See the protocol reference, "A/B: Blastware build vs Thor build".
OBSERVED_DATA_LEN = {
SUB_STORAGE_RANGE: 47, SUB_EVENT_INDEX: 101, SUB_MONITOR_LOG: 297,
SUB_EVENT_RECORD: 221, SUB_SERIAL: 21, SUB_COMPLIANCE_CONFIG: 2103,
SUB_MONITOR_STATUS: 55, SUB_EVENT_FIRST: 19, SUB_EVENT_NEXT: 19,
SUB_CALL_HOME_CONFIG: 137, SUB_TRIGGER_CONFIG: 39,
SUB_SETUP_FIRST: 266, SUB_SETUP_NEXT: 266, SUB_SETUP_ACTIVE: 266,
SUB_STATE: 16, SUB_POLL: 59, SUB_ARM_EVENT: ACK_DATA_LEN,
}
# `1E`/`1F` carry this at params[7]. Series III uses the same value to arm its
# bulk stream; here THOR sends it on every chain read, browse or download.
EVENT_TOKEN = 0xFE
# `SUB 0x5A` request size, in bytes of file payload per response.
#
# ⚠ **16,384, not THOR's 1024.** Measured on UM20147 (2026-10-02): requests of
# 1024 / 2048 / 4096 / 8192 / 16384 all returned byte-identical data against a
# known-good download, and anything larger is **silently clamped to 16,384** —
# correct bytes, short length, no error.
#
# ⚠ The win is real but MODEST, and smaller than a first reading suggests.
# Measured over an RX55, cost per request is ~0.21 s + bytes/2350 — so a download
# is throughput-bound, not round-trip bound. A 72,560-byte event costs ~46 s at
# THOR's 1024 B and ~32 s at 16,384 B: a **30% saving**, not 14x, because ~31 s of
# it is bytes on the wire and no amount of batching addresses that.
#
# Still worth having: 30% faster, and 14x fewer requests is 14x fewer chances for
# a link to drop mid-download.
#
# ⚠ Measured on ONE unit, over USB. The loop below is driven by bytes received
# rather than chunk index, so a unit that clamps lower simply takes more
# requests instead of failing — which is what makes raising this safe.
CHUNK_SIZE = 16384
# THOR's value. Pass `chunk_size=THOR_CHUNK_SIZE` to reproduce its wire traffic
# exactly; the replay test does.
THOR_CHUNK_SIZE = 1024
# Every `0x5A` response prefixes the file bytes with 11 bytes of header.
_CHUNK_PREFIX = 11
# ── Exceptions ────────────────────────────────────────────────────────────────
class ProtocolError(Exception):
"""The device violated the expected protocol."""
class TimeoutError(ProtocolError):
"""No response arrived within the allowed time."""
class ChecksumError(ProtocolError):
"""A received frame failed its checksum."""
class UnexpectedResponse(ProtocolError):
"""The response SUB did not match the request."""
class ShortRead(ProtocolError):
"""A bulk download returned fewer bytes than the device promised."""
# ── Params builders ───────────────────────────────────────────────────────────
def token_params(token: int = EVENT_TOKEN) -> bytes:
"""`1E`/`1F`: the token sits at params[7]."""
return bytes(7) + bytes([token]) + bytes(2)
def key_params(key4: bytes) -> bytes:
"""`0x0C`: the full 4-byte event key at params[4:8]."""
if len(key4) != 4:
raise ValueError(f"key4 must be 4 bytes, got {len(key4)}")
return bytes(4) + key4 + bytes(2)
def key_lo_params(key4: bytes) -> bytes:
"""`0x0A`: only the key's **low two bytes**, at params[6:8].
⚠ Inferred from a single key value. All nine captured `0x0A` frames carry
`4a 81`, and the event key in play was `055d4a81` — so this is consistent
with "the low half of the current key" and equally consistent with "a
cursor handle that happened to equal it". Both readings produce the same
bytes for that key, so one event cannot separate them.
It does not matter much in practice: the walk works with the same params
repeated, so whichever it is, passing the current key is right.
"""
if len(key4) != 4:
raise ValueError(f"key4 must be 4 bytes, got {len(key4)}")
return bytes(6) + key4[2:4] + bytes(2)
def chunk_params(key4: bytes, byte_offset: int) -> bytes:
"""`0x5A`: the key opens the file, then a byte offset walks it.
Chunk 0 carries the event key at params[0:4] — that is what says "from the
beginning". Later chunks carry the byte offset **in that same 4-byte slot**,
as a uint32 BE.
⚠ **Written as a uint32 deliberately, and this matters above 64 KB.** Every
offset THOR was observed to send fits in two bytes — the largest was `0x3400`
(13,312) — so `params[0:2]` was always `00 00` and the field looks like a
uint16 at `params[2:4]`. Reading it that way caps a download at **65,536
bytes**, and UM20147 currently holds a **72,560-byte** event, so that cap is
not hypothetical.
A uint32 here is **byte-identical for every offset below 65,536**, so it
changes nothing that was verified against THOR's frames (the replay test
asserts all 74 of them) and extends the range to 4 GB.
✅ **Confirmed on hardware 2026-10-01.** UM20147's 72,560-byte event
downloaded in **71 chunks** at the exact promised size, which exercises the
carry into `params[1]` on chunks 64–70. It was inference for one commit and
is now evidence.
⚠ This is the **Series III 64 KB page-boundary bug in a new guise** — there,
`parse_strt_end_offset()` discards the key's page byte and the `5A` walk
crashes once a unit's buffer crosses 64 KB, which is *still open* on that
side. The lesson that transfers: an address field whose high bytes are zero
in every capture is not a narrow field, it is an untested one.
"""
if byte_offset == 0:
if len(key4) != 4:
raise ValueError(f"key4 must be 4 bytes, got {len(key4)}")
return key4 + bytes(6)
if not 0 <= byte_offset <= 0xFFFFFFFF:
raise ValueError(f"byte_offset must fit in uint32, got {byte_offset}")
return struct.pack(">I", byte_offset) + bytes(6)
# ── Protocol ──────────────────────────────────────────────────────────────────
class MicromateProtocol:
"""Wire-level command set for one open connection to a Micromate.
Does not own the transport; lifetime belongs to the client.
proto = MicromateProtocol(transport)
proto.poll()
serial = proto.read_serial()
"""
def __init__(
self,
transport: BaseTransport,
recv_timeout: float = DEFAULT_RECV_TIMEOUT,
strict_checksums: bool = True,
) -> None:
"""
Args:
strict_checksums: raise on a bad checksum. **Defaults to True,
unlike the Series III sibling**, which logs and continues
because its parser cannot reliably tell an inner-frame
delimiter from a checksum byte. That excuse does not apply
here: the Micromate rule is plain SUM8 over the de-stuffed
payload and it holds on 251 of 251 captured frames, so a
mismatch means something real — line noise, a desync, or a rule
we have wrong — and all three are worth hearing about.
The lenient Series III default is instructive: it hid the fact
that the documented checksum rule was wrong for two days. Set
False only to get a field diagnosis unstuck.
"""
self._transport = transport
self._recv_timeout = recv_timeout
self._strict = strict_checksums
self._parser = MicromateFrameParser()
self._pending: list[MicromateFrame] = []
# ── Identity and state ────────────────────────────────────────────────────
def poll(self) -> MicromateFrame:
"""`0x5B` → `0xA4`. Handshake; carries the ID block and model string.
Every captured session opens with this and nothing before it.
"""
return self._exchange(SUB_POLL)
def read_serial(self) -> bytes:
"""`0x15` → `0xEA`. ASCII, null-terminated — e.g. `UM12947`."""
return self._read(SUB_SERIAL)
def read_device_info(self) -> bytes:
"""`0x01` → `0xFE`. Firmware, calibration, per-channel float block.
⚠ THOR never sends this in any captured session, so the `0xFFFF` offset
is from our own 2026-09-23 probes rather than from THOR's behaviour. It
answered correctly on both firmware lines, but it is the one read here
with no THOR frame behind it.
"""
return self._read(SUB_DEVICE_INFO)
def read_state(self) -> bytes:
"""`0x49` → `0xB6`. A cheap monitoring check; 16 B.
⚠ Test `data[11]` for **non-zero**, never against a constant — it has
read both `0x0E` and `0x0C` while monitoring.
"""
return self._read(SUB_STATE)
def read_monitor_status(self) -> bytes:
"""`0x1C` → `0xE3`. Flag, **device clock**, battery, memory.
⚠ Parse **forward** from the declared length, never backward from the
end. This block is 4 bytes longer on the Thor firmware line, and Series
III's relative-to-end offsets yield a battery voltage of 577.92 V on a
`11.0BD` unit.
"""
return self._read(SUB_MONITOR_STATUS)
def read_storage_range(self) -> bytes:
"""`0x06` → `0xF9`. Event storage extent; 47 B."""
return self._read(SUB_STORAGE_RANGE)
def read_event_index(self) -> bytes:
"""`0x08` → `0xF7`. 101 B. Contents not yet mapped."""
return self._read(SUB_EVENT_INDEX)
def read_trigger_config(self) -> bytes:
"""`0x2E` → `0xD1`. 39 B. Series IV only; no Series III equivalent."""
return self._read(SUB_TRIGGER_CONFIG)
def read_compliance_config(self) -> bytes:
"""`0x1A` → `0xE5`. The whole active setup — 2103 B on UM12947.
One response. Series III needs a 4-frame sequence for the same thing.
"""
return self._read(SUB_COMPLIANCE_CONFIG)
def read_call_home_config(self) -> bytes:
"""`0x2C` → `0xD3`. 137 B — Series III's is 124, so do not reuse its map."""
return self._read(SUB_CALL_HOME_CONFIG)
# ── Setups ────────────────────────────────────────────────────────────────
def read_active_setup_name(self) -> bytes:
"""`0x41` → `0xBE`. 266 B; carries the active `.MMB` name."""
return self._read(SUB_SETUP_ACTIVE)
def read_first_setup(self) -> bytes:
"""`0x3F` → `0xC0`. Head of the setup-file list."""
return self._read(SUB_SETUP_FIRST)
def read_next_setup(self) -> bytes:
"""`0x40` → `0xBF`. Repeat until the record carries an empty name.
Stateful: the device holds the cursor, so the same request walks the
list. 22 of these appear back to back in one captured session.
"""
return self._read(SUB_SETUP_NEXT)
# ── Event chain ───────────────────────────────────────────────────────────
def arm_event(self) -> MicromateFrame:
"""`0x93` → `0x6C`. THOR sends this before **every** `1E`/`1F`.
It replaces Series III's `1E(token=0xFE)` arming step. No params, no
offset payload — an 11-byte ack.
⚠ Whether a unit actually requires it is untested. Do it because it is
known-good, not because it is known-necessary.
"""
return self._exchange(SUB_ARM_EVENT, offset=READ_ALL)
def read_event_first(self) -> bytes:
"""`0x1E` → `0xE1`. First event key + size; 19 B."""
return self._read(SUB_EVENT_FIRST, params=token_params())
def read_event_next(self) -> bytes:
"""`0x1F` → `0xE0`. Next key + size, or the all-zero null sentinel."""
return self._read(SUB_EVENT_NEXT, params=token_params())
def read_event_record(self, key4: bytes) -> bytes:
"""`0x0C` → `0xF3`. 221 B — project, client, operator, timestamp, peaks.
⚠ The peak float in here runs 2–5% above `max(T,V,L)` and is **not** the
vector sum; its offset was inferred, not established. Prefer decoded
samples.
"""
return self._read(SUB_EVENT_RECORD, params=key_params(key4))
def read_monitor_log_next(self, key4: bytes) -> Optional[bytes]:
"""`0x0A` → `0xF5`. One monitor-log record, or None at end of list.
⚠ Not the keyed single read the spec describes. This is a **walk**:
the same request repeated, the device advancing its own cursor, each
response a 297-byte record carrying serial, mode and thresholds. The
list ends with a bare 11-byte ack — nine captured frames, eight records
then the terminator.
Series III reaches the same data through a record-type discriminator on
its event walk (`0x2C` partial vs `0x46` full). Here it is a separate
cursor and the event chain does not see it at all.
"""
data = self._read(SUB_MONITOR_LOG, params=key_lo_params(key4))
return None if len(data) <= ACK_DATA_LEN else data
# ── Bulk download ─────────────────────────────────────────────────────────
def read_event_file(self, key4: bytes, size: int, *,
chunk_size: int = CHUNK_SIZE) -> bytes:
"""`0x5A` → `0xA5`. The `.IDFW`/`.IDFH` file, byte for byte.
`size` is the 4 bytes after the key in the `1E`/`1F` response. Returns
exactly that many bytes, or raises `ShortRead`.
A bounded walk — `ceil(size / chunk_size)` requests, each asking for
`min(chunk_size, remaining)` bytes:
offset = the byte count wanted (NOT an address)
params = the key on chunk 0, then a uint16 BE byte offset
response = exactly `offset + 11` bytes; file bytes are data[11:]
Verified against THOR on all six bench events (4,076 → 13,424 B):
`sum(offsets) == size` exactly, every time.
⚠ Do not port the Series III `5A` walk. Its address arithmetic caused a
5x over-read and a `>64 KB` page-boundary bug that is *still open* on
that side. Neither applies here — the cursor is a byte offset into the
file, bounded by a size the device supplied, so it cannot run past the
event.
The result feeds `micromate.idf_file.read_idf_file()` and
`/db/import/idf_file` unchanged; no new codec work is needed.
"""
if size <= 0:
raise ValueError(f"size must be positive, got {size}")
if chunk_size < 1:
raise ValueError(f"chunk_size must be positive, got {chunk_size}")
# ⚠ Driven by BYTES RECEIVED, not by chunk index.
#
# The device silently clamps an over-large request: ask for 32,768 and it
# returns exactly 16,384 — correct bytes, short length, no error. A loop
# that strides by a fixed chunk size would either fail on that or, worse,
# skip the bytes it never collected. Tracking the offset by what actually
# arrived makes the clamp a non-event: it just takes another request.
#
# That also makes this self-correcting against any short response, which
# is the failure mode this codebase has been bitten by repeatedly on the
# Series III side — there, a short read surfaced as a silently truncated
# channel.
out = bytearray()
requests = 0
while len(out) < size:
want = min(chunk_size, size - len(out))
data = self._read(
SUB_BULK_DOWNLOAD,
offset=want,
params=chunk_params(key4, len(out)),
)
requests += 1
if len(data) < _CHUNK_PREFIX:
raise ShortRead(
f"{key4.hex()} at offset {len(out)}: {len(data)} B is too "
f"short to hold a chunk header"
)
body = data[_CHUNK_PREFIX:]
if not body:
# No progress at all — continuing would spin forever.
raise ShortRead(
f"{key4.hex()} at offset {len(out)}: asked for {want} B and "
f"got none; {len(out)} of {size} B assembled"
)
if len(body) < want:
log.debug("%s: asked %d B at offset %d, served %d — clamped",
key4.hex(), want, len(out), len(body))
out += body
if len(out) != size:
raise ShortRead(
f"{key4.hex()}: assembled {len(out)} B, device promised {size}"
)
log.debug("downloaded %s: %d B in %d request(s)",
key4.hex(), len(out), requests)
return bytes(out)
# ── Plumbing ──────────────────────────────────────────────────────────────
def _read(
self,
sub: int,
*,
params: bytes = bytes(10),
offset: Optional[int] = None,
timeout: Optional[float] = None,
) -> bytes:
"""Send one read command, return the response's data section."""
return self._exchange(sub, params=params, offset=offset, timeout=timeout).data
def _exchange(
self,
sub: int,
*,
params: bytes = bytes(10),
offset: Optional[int] = None,
timeout: Optional[float] = None,
) -> MicromateFrame:
if offset is None:
offset = _OFFSETS.get(sub, READ_ALL)
# Start every exchange clean: drop any half-frame and any frame left
# stashed by the last one. This is a strict request/response protocol,
# so anything already buffered when we send is by definition stale, and
# `expected_sub` would reject it anyway — better to discard it here than
# to raise a confusing UnexpectedResponse one command later.
self._parser.reset()
self._pending.clear()
self._send(build_request(sub, offset, params))
return self._recv_one(expected_sub=0xFF - sub, timeout=timeout,
reset_parser=False)
def _send(self, frame: bytes) -> None:
log.debug("TX %d bytes: %s", len(frame), frame.hex())
self._transport.write(frame)
def _recv_one(
self,
expected_sub: Optional[int] = None,
timeout: Optional[float] = None,
reset_parser: bool = True,
) -> MicromateFrame:
"""Read until one complete frame is parsed."""
deadline = time.monotonic() + (timeout or self._recv_timeout)
if reset_parser:
self._parser.reset()
self._pending.clear()
if self._pending:
return self._validate(self._pending.pop(0), expected_sub)
while time.monotonic() < deadline:
chunk = self._transport.read(4096)
if not chunk:
time.sleep(0.005)
continue
log.debug("RX %d bytes", len(chunk))
frames = self._parser.feed(chunk)
if frames:
self._pending.extend(frames[1:])
return self._validate(frames[0], expected_sub)
raise TimeoutError(
f"no frame in {timeout or self._recv_timeout:.1f}s"
+ (f" (expected SUB 0x{expected_sub:02X})" if expected_sub is not None else "")
+ f"; {self._parser.bytes_fed} bytes were received"
# That byte count is the whole point: it separates "nothing came
# back at all" from "bytes arrived but never framed", and those have
# completely different causes. It earned its keep on Series III.
)
def _validate(
self, frame: MicromateFrame, expected_sub: Optional[int]
) -> MicromateFrame:
if not frame.checksum_valid:
msg = (
f"SUB 0x{frame.sub:02X}: checksum mismatch "
f"(got 0x{frame.chk_byte:02X}, {len(frame.data)} B data)"
)
if self._strict:
raise ChecksumError(msg)
log.warning("%s — continuing (strict_checksums=False)", msg)
if expected_sub is not None and frame.sub != expected_sub:
raise UnexpectedResponse(
f"expected SUB 0x{expected_sub:02X}, got 0x{frame.sub:02X}"
)
return frame
-89
View File
@@ -1,89 +0,0 @@
r"""Decode the Thor / Micromate (series-4) sensor self-check waveforms from an
IDFW event binary.
Reverse-engineered 2026-09-15 against 4 UM (Thor) oracle events. The IDFW
binary carries the sensor self-check in its fixed-header region (before the
waveform body), as up to four records tagged ``01 0e 3c/3d/3e/3f`` — the SAME
channel ids as the series-3 MiniMate Plus (Tran / Vert / Long / MicL), which is
the physical self-test:
* 3c / 3d / 3e = Tran / Vert / Long geophone ring-downs (a damped impulse
response — resonant frequency + damping).
* 3f = MicL pulse train (the mic's known-signal gain check). Absent
on three-channel (mic-disabled) units.
Record framing (per record)::
01 0e [id:1] [flags:3] [count:2 BE] [pad:10] [int16-BE samples × count]
\___ 18-byte header ___/
Unlike series-3's delta-coded trailing block, series-4 stores each trace as a
raw int16 big-endian array. ``count`` (the 2-byte field at header offset +8)
is the sample count; the record is padded to a fixed stride after that.
"""
from __future__ import annotations
import struct
from typing import Dict, List
# Record id → channel. Same ids/order as series-3 (minimateplus.sensor_check).
_ID_TO_CHANNEL = {0x3C: "Tran", 0x3D: "Vert", 0x3E: "Long", 0x3F: "MicL"}
_CHAIN_IDS = (0x3C, 0x3D, 0x3E, 0x3F)
_MARKER = b"\x01\x0e" # precedes the 1-byte channel id
_HEADER_LEN = 18 # bytes from the marker start to the first sample
_COUNT_OFF = 8 # 2-byte BE sample count, from the marker start
_MAX_COUNT = 4000 # sanity cap (traces are ~70-200 samples)
def _find_chain(raw: bytes):
"""Locate the sensor-check record chain. Returns a list of
``(offset, id, count)`` for the first run of markers whose ids run
3c, 3d, 3e[, 3f] in order, or ``[]``.
Records are padded to a fixed stride, so the next marker is not at
``header + count*2``; instead collect every ``01 0e [id]`` marker with a
sane count and take the first id-ordered run. Validating the id sequence
(not a lone ``01 0e 3c``) keeps a stray marker in the waveform body from
matching — the real chain sits in the fixed header, ahead of the body.
"""
n = len(raw)
markers = []
for p in range(n - _HEADER_LEN):
if raw[p:p + 2] == _MARKER and raw[p + 2] in _ID_TO_CHANNEL:
count = int.from_bytes(raw[p + _COUNT_OFF:p + _COUNT_OFF + 2], "big")
if 0 < count <= _MAX_COUNT:
markers.append((p, raw[p + 2], count))
for i, (off, rid, _c) in enumerate(markers):
if rid != 0x3C:
continue
run = [markers[i]]
for m in markers[i + 1:]:
if len(run) < len(_CHAIN_IDS) and m[1] == _CHAIN_IDS[len(run)]:
run.append(m)
else:
break
if len(run) >= 3: # 3-channel (mic-disabled) units are valid
return run
return []
def decode_idf_sensor_check(raw: bytes) -> Dict[str, List[int]]:
"""Decode the sensor self-check traces from a Thor/Micromate IDFW binary.
Returns ``{"Tran": [...], "Vert": [...], "Long": [...], "MicL": [...]}`` in
raw int16 ADC counts (MicL omitted on 3-channel units), or ``{}`` if the
binary carries no sensor-check chain (a non-IDF file, or an IDFH histogram).
"""
chain = _find_chain(raw)
if not chain:
return {}
out: Dict[str, List[int]] = {}
for off, rid, count in chain:
start = off + _HEADER_LEN
blob = raw[start:start + count * 2]
if len(blob) < count * 2:
continue
out[_ID_TO_CHANNEL[rid]] = list(struct.unpack(">%dh" % count, blob))
return out
-154
View File
@@ -1,154 +0,0 @@
"""
setup_block.py — the Micromate setup block (`SUB 0x1A`), decoded.
Pure byte interpretation: no I/O, no device. `MicromateClient.get_setup()`
does the read and hands the content here.
Every offset below is into **content** (response data minus its 11-byte prefix)
and was measured on UM20147 (`11.0BD`) by changing one setting on the unit's own
keypad and watching which bytes moved, 2026-10-17/19. Method, grades and the
fields deliberately left out are in docs/micromate_protocol_reference.md, under
*The `0x1A` field map from a keypad pass* and the 2026-10-19 section after it.
"""
from __future__ import annotations
import struct
from .models import MicromateSetup
from .protocol import ProtocolError
class SetupChecksumError(ProtocolError):
"""A config block's trailing CRC does not match its contents."""
_CRC_POLY = 0x1021
_CRC_INIT = 0x1D0F # CRC-16/AUG-CCITT
_CONTENT_SIZE = 2092 # = content[0:2] (2090) + the 2-byte CRC
# ── Head of the block ─────────────────────────────────────────────────────────
_MODE = 5 # 01 Waveform · 02 Manual · 03 Histogram · 04 Combo
_SAMPLE_RATE = slice(6, 8) # uint16 BE ⚠ 4096 puts a literal 0x10 here
_HIST_INTERVAL = slice(8, 10) # uint16 BE seconds
_PRETRIGGER = 12 # f32 BE, NEGATIVE seconds
_STOP_MODE = 17 # 00 Fixed · 01 Auto (u8 or u16 BE [16:18] — unresolved)
_RECORD_TIME = 18 # f32 BE seconds
_AUTO_STOP = 23 # seconds (u8 or u16 BE [22:24] — unresolved)
_SENSORS = 25 # bitmask: 0x07 geophones, 0x08 mic
_TRIGGERS = 29 # same bits: which sensors may trigger
_DISTANCE = 30 # f32 BE metres (keypad: ft / 3.2808)
_CHARGE = 34 # f32 BE kg (keypad: lb / 2.21)
_REPORT_FLAGS = 39 # 0x02 job number on · 0x08 scaled distance on · 0x01 ?
_JOB_NUMBER = slice(40, 42) # uint16 BE
_NAME = slice(42, 86) # setup file name, null-padded
_GEO_BITS, _MIC_BIT = 0x07, 0x08
_JOB_ON, _SCALED_ON = 0x02, 0x08
# ── Notes: four [label 22][value 42] pairs on a 64-byte stride ────────────────
_NOTE_LABEL, _NOTE_VALUE, _NOTE_STRIDE, _NOTES = 122, 144, 64, 4
# ── Channel blocks, 48 bytes each from content[1708] ──────────────────────────
# 1-3 are the geophones. Block 4 is the ACTIVE mic: a byte copy of block 5
# (stored linear settings) or block 6 (stored sound-level settings). Read the
# mic from block 4 only — 5 and 6 describe whichever mic is NOT selected.
_CHANNELS, _CHANNEL_SIZE = 1708, 48
_CH_SENSOR_CODE = slice(4, 8) # uint32 BE: 1 geophone, 2 linear mic, 9 SLM, 0 off
_CH_TRIGGER = 30 # f32 BE: geophone in/s, linear mic psi
_ACTIVE_MIC = 3 # block index (0-based)
_MIC_TYPES = {2: "linear", 9: "sound_level"}
def _crc16_aug_ccitt(data: bytes) -> int:
c = _CRC_INIT
for b in data:
c ^= b << 8
for _ in range(8):
c = ((c << 1) ^ _CRC_POLY) & 0xFFFF if c & 0x8000 else (c << 1) & 0xFFFF
return c
def crc_ok(content: bytes) -> bool:
"""True if a config block's trailing checksum matches its contents.
One rule covers the setup (`0x1A`), preferences (`0x08`) and `0x2E` blocks:
``content[0:2]`` is a uint16 BE length N, and a CRC-16/AUG-CCITT over
``content[0:N-2]`` is stored big-endian at ``content[N:N+2]``. The two bytes
at ``[N-2:N]`` are zero and not covered. `0x2C` (call-home) has no checksum.
A block too short to hold its own declared length reads as bad, not as an
error: a truncated read is exactly what this exists to catch.
"""
if len(content) < 2:
return False
n = int.from_bytes(content[0:2], "big")
if n < 2 or len(content) < n + 2:
return False
return _crc16_aug_ccitt(content[: n - 2]) == int.from_bytes(content[n : n + 2], "big")
def _f32(c: bytes, offset: int) -> float:
return struct.unpack_from(">f", c, offset)[0]
def _ascii(buf: bytes) -> str:
return buf.split(b"\x00")[0].decode("ascii", "replace").strip()
def _channel(c: bytes, index: int) -> bytes:
start = _CHANNELS + index * _CHANNEL_SIZE
return c[start : start + _CHANNEL_SIZE]
def decode_setup(content: bytes, *, verify: bool = True) -> MicromateSetup:
"""Decode a setup block's content (``0x1A`` data minus its 11-byte prefix).
Raises ``SetupChecksumError`` if the trailing CRC does not match — unless
``verify=False``, which decodes anyway, for looking at what a bad read held.
A block shorter than 2,092 bytes raises ``ProtocolError`` either way: the
checksum is optional, the bounds are not.
"""
if len(content) < _CONTENT_SIZE:
raise ProtocolError(f"setup block content is {len(content)} B, need {_CONTENT_SIZE}")
if verify and not crc_ok(content):
raise SetupChecksumError(
"setup block checksum mismatch — a short or corrupt read "
"(decode_setup(..., verify=False) to inspect it anyway)"
)
c = content
mic = _channel(c, _ACTIVE_MIC)
mic_code = int.from_bytes(mic[_CH_SENSOR_CODE], "big")
mic_type = _MIC_TYPES.get(mic_code, f"unknown ({mic_code})")
flags = c[_REPORT_FLAGS]
notes = {}
for n in range(_NOTES):
label = _ascii(c[_NOTE_LABEL + n * _NOTE_STRIDE : _NOTE_VALUE + n * _NOTE_STRIDE])
value = _ascii(c[_NOTE_VALUE + n * _NOTE_STRIDE : _NOTE_LABEL + (n + 1) * _NOTE_STRIDE])
notes[label] = value
return MicromateSetup(
name=_ascii(c[_NAME]),
record_mode=c[_MODE],
sample_rate=int.from_bytes(c[_SAMPLE_RATE], "big"),
histogram_interval_s=int.from_bytes(c[_HIST_INTERVAL], "big"),
pretrigger_s=-_f32(c, _PRETRIGGER),
auto_record_stop=bool(c[_STOP_MODE]),
record_time_s=_f32(c, _RECORD_TIME),
auto_stop_after_s=c[_AUTO_STOP],
geophones_active=bool(c[_SENSORS] & _GEO_BITS),
mic_active=bool(c[_SENSORS] & _MIC_BIT),
trigger_on_geophones=bool(c[_TRIGGERS] & _GEO_BITS),
trigger_on_mic=bool(c[_TRIGGERS] & _MIC_BIT),
geo_trigger_ips=tuple(_f32(_channel(c, i), _CH_TRIGGER) for i in range(3)),
mic_type=mic_type,
mic_trigger_psi=_f32(mic, _CH_TRIGGER) if mic_type == "linear" else None,
job_number_enabled=bool(flags & _JOB_ON),
job_number=int.from_bytes(c[_JOB_NUMBER], "big"),
scaled_distance_enabled=bool(flags & _SCALED_ON),
distance_m=_f32(c, _DISTANCE),
charge_weight_kg=_f32(c, _CHARGE),
notes=notes,
raw=c,
)
-75
View File
@@ -1,75 +0,0 @@
"""Structural annotation of a Series-3 Blastware waveform binary.
Pure, no I/O: takes the raw file bytes and returns a flat, gap-free tiling of
labelled :class:`Span` regions for a hex viewer to paint. Every byte is
covered — anything the decoder can't account for becomes an ``unknown`` span,
so undecoded regions (e.g. a stored spectral/FFT block, if one exists) stand
out instead of hiding.
File layout (see ``blastware_file.py``): ``[header][21B STRT][body][26B footer]``.
The body is the record chain walked by :func:`waveform_codec.walk_records`.
"""
from __future__ import annotations
from dataclasses import dataclass
from typing import List
from .waveform_codec import walk_records
_STRT_LEN = 21
_FOOTER_LEN = 26
@dataclass
class Span:
start: int # inclusive byte offset
end: int # exclusive byte offset
label: str # human-readable description
kind: str # 'header' | 'strt' | 'sample' | 'footer' | 'unknown'
def _tile(known: List[Span], total: int) -> List[Span]:
"""Sort *known* spans and fill every gap with an ``unknown`` span, so the
result is a contiguous, non-overlapping tiling of ``[0, total)``. Overlaps
are resolved by clamping to the running position (first writer wins)."""
out: List[Span] = []
pos = 0
for s in sorted(known, key=lambda x: (x.start, x.end)):
if s.end <= pos:
continue # fully behind — dropped overlap
start = max(s.start, pos)
if start > pos:
out.append(Span(pos, start, "unknown", "unknown"))
out.append(s if start == s.start else Span(start, s.end, s.label, s.kind))
pos = s.end
if pos < total:
out.append(Span(pos, total, "unknown", "unknown"))
return out
def annotate_blastware_binary(raw: bytes) -> List[Span]:
"""Annotate a Series-3 waveform binary into a gap-free list of spans."""
total = len(raw)
strt_pos = raw.find(b"STRT")
if strt_pos < 0:
return [Span(0, total, "unrecognized — no STRT record", "unknown")]
known: List[Span] = []
if strt_pos > 0:
known.append(Span(0, strt_pos, "File header", "header"))
known.append(Span(strt_pos, strt_pos + _STRT_LEN, "STRT record", "strt"))
body_start = strt_pos + _STRT_LEN
footer_start = total - _FOOTER_LEN
if footer_start >= body_start:
known.append(Span(footer_start, total, "File footer", "footer"))
else:
footer_start = total # file too short for a footer
body = raw[body_start:footer_start]
for rec in walk_records(body):
hi, lo = rec["mode"]
label = f"{rec['channel']} record (seg {rec['segment_index']}, mode {hi:02x} {lo:02x})"
known.append(Span(body_start + rec["offset"], body_start + rec["end"], label, "sample"))
return _tile(known, total)
+1 -75
View File
@@ -450,7 +450,7 @@ class MiniMateClient:
proto.confirm_erase_all()
log.info("delete_all_events: erase confirmed — device memory cleared")
def get_events(self, full_waveform: bool = False, debug: bool = False, stop_after_index: Optional[int] = None, skip_waveform_for_keys: Optional[set] = None, skip_waveform_for_events: Optional[dict] = None, extra_chunks_after_metadata: int = 1, headers_only: bool = False, only_key: Optional[bytes] = None, only_key_timestamp: Optional[str] = None) -> list[Event]:
def get_events(self, full_waveform: bool = False, debug: bool = False, stop_after_index: Optional[int] = None, skip_waveform_for_keys: Optional[set] = None, skip_waveform_for_events: Optional[dict] = None, extra_chunks_after_metadata: int = 1) -> list[Event]:
"""
Download all stored events from the device using the confirmed
1E → 0A → 0C → 5A → 1F event-iterator protocol.
@@ -479,24 +479,8 @@ class MiniMateClient:
Raises:
ProtocolError: on unrecoverable communication failure.
headers_only: never start a 5A -- every event takes the bypass below.
only_key: download only the event with this key (in full, per
full_waveform); walk the others without their 5A, and stop once
that event is read.
only_key_timestamp: with only_key, the ISO timestamp (as
`_event_timestamp_iso` formats it, e.g. "2026-10-01T08:00:00") the
event was listed with. If the 0C at only_key says another time, or
gave none, that event is returned without its 5A -- 1F(arm), POLL
and 5A are not sent -- and the caller reports which.
Strict mode (headers_only, or only_key): a list or a one-event download
must be all or nothing, so a lost 0A or 1F reply re-raises its
ProtocolError instead of skipping an event or ending the walk early,
and a 1F that returns a key already walked raises ProtocolError.
Without those options (legacy) the walk is exactly as it was.
"""
proto = self._require_proto()
strict = headers_only or only_key is not None
log.info("get_events: requesting first event (SUB 1E)")
try:
@@ -513,7 +497,6 @@ class MiniMateClient:
events: list[Event] = []
idx = 0
seen: set = set() # strict mode: keys walked, to catch a chain that does not advance
# Legacy bare-key skip set is deprecated: the device's key counter
# resets to 0x01110000 after every memory erase, so a key in this set
@@ -531,10 +514,6 @@ class MiniMateClient:
while data8[4:8] != b"\x00\x00\x00\x00":
cur_key = key4 # key for this event's 0A/1E-arm/0C/5A calls
if strict and cur_key in seen:
raise ProtocolError(
f"event chain did not advance: key {cur_key.hex()} came back twice")
seen.add(cur_key)
log.info("get_events: record %d key=%s", idx, cur_key.hex())
ev = Event(index=idx)
@@ -552,8 +531,6 @@ class MiniMateClient:
)
proceed = False
except ProtocolError as exc:
if strict:
raise
log.warning(
"get_events: 0A failed for key=%s: %s — skipping",
cur_key.hex(), exc,
@@ -600,19 +577,6 @@ class MiniMateClient:
"get_events: key=%s (key, ts=%s) match — skipping 5A bulk download",
cur_key.hex(), actual_ts,
)
elif headers_only or (only_key is not None and cur_key != only_key):
# The same bypass as a (key, ts) match: 0A + 1E(arm) + 0C were
# read; 1F(arm) + POLL + 5A are not sent, and 1F(browse) below is
# safe because no 5A was ever started.
skip_5a = True
elif (only_key is not None and only_key_timestamp is not None
and actual_ts != only_key_timestamp):
# The event at this key is not the one asked for -- erased or
# wrapped since it was listed, or its 0C reply was lost. Do
# not download it; the caller reports which.
log.info("get_events: key=%s is from %r, not %r -- no 5A",
cur_key.hex(), actual_ts, only_key_timestamp)
skip_5a = True
arm_key4: Optional[bytes] = None
a5_ok = False
@@ -716,8 +680,6 @@ class MiniMateClient:
key4.hex(), data8[4:8].hex(),
)
except ProtocolError as exc:
if strict:
raise
log.warning("get_events: 1F(browse) failed: %s — stopping", exc)
key4 = b"\x00\x00\x00\x00"
data8 = b"\x00\x00\x00\x00\x00\x00\x00\x00"
@@ -751,10 +713,6 @@ class MiniMateClient:
events.append(ev)
idx += 1
if only_key is not None and cur_key == only_key:
log.info("get_events: read key=%s -- stopping", cur_key.hex())
break
# Early exit: if the caller only wants events up to a specific
# index, stop iterating once we've collected it.
if stop_after_index is not None and idx > stop_after_index:
@@ -777,44 +735,12 @@ class MiniMateClient:
key4.hex(), data8[4:8].hex(),
)
except ProtocolError as exc:
if strict:
raise
log.warning("get_events: 1F failed: %s — stopping iteration", exc)
break
log.info("get_events: downloaded %d event(s)", len(events))
return events
def list_event_headers(self) -> list[Event]:
"""Every stored event's 0C record -- timestamp, type, peaks -- without its 5A.
`get_events()` downloads every event in full even for metadata
(`stop_after_metadata` is a no-op), so listing that way costs one
complete download per event. This walks 0A + 1E(arm) + 0C + 1F(browse)
per event -- the bypass `skip_waveform_for_events` already takes -- and
never starts a 5A. The events carry no `_a5_frames`.
"""
return self.get_events(headers_only=True)
def download_event_by_key(self, key4: bytes, *, expected_timestamp: Optional[str] = None) -> Optional[Event]:
"""Download ONE event in full; walk past the events before it without
their 5A. None if no full record has that key.
`get_events(stop_after_index=N)` downloads events 0..N in full and keeps
one; this downloads only the one asked for.
`expected_timestamp` (ISO, as `_event_timestamp_iso` writes it): the
time the event was listed with. If the 0C read at that key says
otherwise -- or could not be read -- the event comes back without its
5A (`_a5_frames` None) and nothing is downloaded; the caller compares
the timestamp and says which.
"""
for ev in self.get_events(full_waveform=True, only_key=key4,
only_key_timestamp=expected_timestamp):
if ev._waveform_key == key4:
return ev
return None
def download_waveform(self, event: Event) -> None:
"""
Download the full raw ADC waveform for a previously-retrieved event
+2 -69
View File
@@ -50,7 +50,7 @@ SIDECAR_KIND = "sfm.event"
# bumped without a `pip install` re-run — leading to confusing stale
# version stamps in sidecars. Bump this constant and CHANGELOG.md
# together at release time.
TOOL_VERSION = "0.31.0" # +/sensor_check group (schema v2); gates the backfill regen
TOOL_VERSION = "0.29.0"
try:
# Best-effort: prefer the installed metadata when it's NEWER than the
@@ -296,16 +296,6 @@ def apply_report_to_event(event: Event, report: BwAsciiReport) -> None:
event.sample_rate = report.sample_rate_sps
if report.record_time_s is not None:
event.rectime_seconds = report.record_time_s
# The report's event_datetime is Blastware's exact trigger time (parsed
# from Event Time + Event Date). Prefer it over the binary footer's stop
# time so a report-paired import matches BW to the second.
edt = report.event_datetime
if edt is not None:
event.timestamp = Timestamp(
raw=b"", flag=0x10,
year=edt.year, unknown_byte=0, month=edt.month, day=edt.day,
hour=edt.hour, minute=edt.minute, second=edt.second,
)
def apply_bw_report_dict_to_event(event: Event, bw_report: dict) -> None:
@@ -818,30 +808,6 @@ def derive_record_type_from_filename(filename, default: str = "Waveform") -> str
return _RECORD_TYPE_BY_EXT_SUFFIX.get(ext[-1].upper(), default)
# Marker for the recording-setup config block, and the offset of the record-time
# float32 within it. The configured post-trigger record time (seconds) is a
# big-endian float32 exactly 30 bytes before the "Standard Recording Setup"
# label. Verified across the corpus reading 1.0 / 2.0 / 3.0 s on different
# setups — and ts2 - record_time reproduces Blastware's trigger to the second
# (N844LQHB: stop 10:33:32 - 3.0 = 10:33:29).
_RECSETUP_MARKER = b"Standard Recording Setup"
_RECTIME_OFFSET_BEFORE_MARKER = 30
def _parse_record_time_seconds(raw: bytes) -> Optional[float]:
"""The configured post-trigger record time in seconds, from the recording-
setup config block, or None when absent / implausible."""
a = raw.find(_RECSETUP_MARKER)
if a < _RECTIME_OFFSET_BEFORE_MARKER:
return None
off = a - _RECTIME_OFFSET_BEFORE_MARKER
try:
rt = struct.unpack(">f", raw[off:off + 4])[0]
except struct.error:
return None
return rt if 0.05 <= rt <= 600.0 else None
def read_blastware_file(path: Union[str, Path]) -> Event:
"""
Parse a Blastware waveform file into an Event.
@@ -951,10 +917,6 @@ def read_blastware_file(path: Union[str, Path]) -> Event:
# rest of the event (timestamp, waveform_key, project strings) is
# still recoverable and useful.
decoded = decode_waveform_v2(body)
# Discriminator for the timestamp logic below: a waveform (trigger) event
# vs a histogram window. Keyed on the codec, not the filename — the
# save_imported_bw path passes a tmp ".bw" name whose extension lies.
is_waveform_body = decoded is not None
if decoded is None:
decoded = decode_histogram_body(body)
if decoded is None:
@@ -986,31 +948,7 @@ def read_blastware_file(path: Union[str, Path]) -> Event:
ev.total_samples = strt_fields.get("total_samples")
ev.pretrig_samples = strt_fields.get("pretrig_samples")
# Event timestamp. The footer's two timestamps mean different things by
# record type:
# * Waveform: ts1 = the monitoring-SESSION start (shared across every
# event that day — a unit arming at 06:00 stamps 06:00 on all of them),
# ts2 = THIS event's recording STOP. Blastware's Date/Time is the
# TRIGGER = ts2 - record time, and the record time is a float32 in the
# recording-setup config block (see _parse_record_time_seconds), so the
# exact trigger is recoverable from the binary alone. Falls back to ts2
# (the stop, within the record duration) if the config block is absent.
# (Stamping ts1 showed the session start, hours off.)
# * Histogram / undecodable: ts1 = the window start, which IS the event
# time — keep it.
# Discriminate by ``is_waveform_body`` (the codec), not the filename.
if is_waveform_body and ts2 is not None:
_stop = datetime.datetime(ts2.year, ts2.month, ts2.day,
ts2.hour, ts2.minute, ts2.second)
_rt = _parse_record_time_seconds(raw)
_trig = _stop - datetime.timedelta(seconds=_rt) if _rt is not None else _stop
ev.timestamp = Timestamp(
raw=footer[10:18],
flag=0x10,
year=_trig.year, unknown_byte=0, month=_trig.month, day=_trig.day,
hour=_trig.hour, minute=_trig.minute, second=_trig.second,
)
elif ts1 is not None:
if ts1 is not None:
ev.timestamp = Timestamp(
raw=footer[2:10],
flag=0x10,
@@ -1022,11 +960,6 @@ def read_blastware_file(path: Union[str, Path]) -> Event:
project=project, client=client, operator=user, sensor_location=seisloc,
)
ev.raw_samples = samples
# Sensor self-check traces from the binary's trailing block (waveform
# events only; returns {} for histograms / when absent). Carried on the
# Event so the .h5 writer persists them device-agnostically.
from minimateplus.sensor_check import decode_sensor_check
ev.sensor_check = decode_sensor_check(raw) or None
# Only compute peaks from samples when we actually have samples.
# For events the codec couldn't decode (histogram-mode bodies, until
# the §7.6.2 histogram codec is wired in), samples is an empty dict
-9
View File
@@ -544,15 +544,6 @@ class Event:
pretrig_samples: Optional[int] = None # from STRT record: pre-trigger sample count
rectime_seconds: Optional[int] = None # from STRT record: record duration (seconds)
# Sensor self-check traces keyed by channel label — the short diagnostic
# waveforms the unit records when it pulses each sensor before monitoring
# (geophone ring-downs + a mic pulse train). Decoded from the binary by
# the per-series decoder (minimateplus.sensor_check / micromate.sensor_check)
# and carried here so the .h5 writer can persist them device-agnostically.
# Raw ADC counts; the source series' scale differs but the trace is a
# shape diagnostic (rendered fit-to-box). None when absent.
sensor_check: Optional[dict] = None # {"Tran": [...], ..., "MicL": [...]}
# ── Debug / introspection ─────────────────────────────────────────────────
# Raw 210-byte waveform record bytes, set when debug mode is active.
# Exposed by the SFM server via ?debug=true so field layouts can be verified.
-146
View File
@@ -1,146 +0,0 @@
r"""Decode the Blastware sensor self-check waveforms from a series-3 event binary.
Reverse-engineered 2026-09-15 against 7 BE12844 (MiniMate Plus) oracle events.
After the main waveform record-chain and the trailing metadata / per-channel
calibration records, the binary carries four length-prefixed records tagged
0x3c-0x3f: the sensor self-check traces the unit records when it pulses each
sensor before monitoring. Blastware draws these as the little waveforms in the
"Sensor Check" strip on the right of the Event Report.
* 0x3c / 0x3d / 0x3e = Tran / Vert / Long geophone ring-downs (a damped
oscillation at the geophone's resonance, ~7-8 Hz at 1024 sps).
* 0x3f = MicL, a pulse train at the mic self-test frequency
(~20 Hz), whose zero-crossing frequency is BW's mic "Channel Test" freq.
Record framing (per record, all four chained by their length prefix)::
[len:2 BE][id:1][00 00][Nchan:1][12-byte header][delta stream][40 02][6B]
\_________________ payload (len bytes) _______________________________/
The delta stream is ``payload[20 : len-8]`` (the ``40 02`` terminator sits at
``len-8``, followed by 6 trailing bytes). It uses the exact same 10/20/30/00
delta-block tags as the main waveform codec
(:mod:`minimateplus.waveform_codec`), decoded here from an implicit anchor of 0
— so the traces come out in the same 16-count raw units as the main waveform
(LSB = 0.005 in/s at Normal range for the geophones).
"""
from __future__ import annotations
from typing import Dict, List
from minimateplus.waveform_codec import walk_body
# Record id → channel. Order mirrors the trailing per-channel calibration
# records (Tran / Vert / Long / MicL), confirmed against BW's sensor-check
# frequencies on all 7 oracle events.
_ID_TO_CHANNEL = {0x3C: "Tran", 0x3D: "Vert", 0x3E: "Long", 0x3F: "MicL"}
_CHAIN_IDS = (0x3C, 0x3D, 0x3E, 0x3F)
_HEADER_LEN = 20 # payload bytes before the delta stream
_TRAILER_LEN = 8 # 40 02 terminator + 6 trailing bytes after the stream
def _s4(nib: int) -> int:
"""Sign-extend a 4-bit nibble delta."""
return nib - 16 if nib >= 8 else nib
def _i8(byte: int) -> int:
"""Sign-extend an 8-bit int delta."""
return byte - 256 if byte >= 128 else byte
def _decode_delta_stream(buf: bytes) -> List[int]:
"""Accumulate a 10/20/30/00 delta-block stream from an anchor of 0,
stopping at the 0x40 terminator.
Mirrors the block semantics in
:func:`minimateplus.waveform_codec.decode_waveform_v2` (fully decoded &
byte-exact as of 2026-05-11); see that module for the format details.
"""
out: List[int] = []
cur = 0
for blk in walk_body(buf, 0):
fam = blk.tag_hi & 0xF0
if fam == 0x10:
# nibble deltas, high nibble first
for byte in blk.data:
for nib in ((byte >> 4) & 0xF, byte & 0xF):
cur += _s4(nib)
out.append(cur)
elif fam == 0x20:
# int8 deltas
for byte in blk.data:
cur += _i8(byte)
out.append(cur)
elif fam == 0x30:
# 12-bit signed deltas, packed as tag_lo/4 groups of 6 bytes
for g in range(blk.tag_lo // 4):
grp = blk.data[g * 6:(g + 1) * 6]
if len(grp) < 6:
break
high_word = (grp[0] << 8) | grp[1]
for k in range(4):
nib = (high_word >> (12 - 4 * k)) & 0xF
v = (nib << 8) | grp[2 + k]
if v >= 0x800:
v -= 0x1000
cur += v
out.append(cur)
elif fam == 0x00:
# RLE zero-delta run (wide form carries the high nibble in the tag)
run = ((blk.tag_hi & 0x0F) << 8) | blk.tag_lo
out.extend([cur] * run)
elif fam == 0x40:
# segment / record terminator
break
return out
def _find_chain(body: bytes):
"""Locate the four length-prefixed sensor-check records.
Returns a list of ``(offset, id, length)`` or ``None``. The chain is
validated by walking the ids 0x3c → 0x3d → 0x3e → 0x3f via their own length
prefixes, so a stray 0x3c byte in the waveform data cannot match.
"""
for p in range(len(body) - 6):
if body[p + 2] == 0x3C and body[p + 3] == 0 and body[p + 4] == 0:
q = p
recs = []
ok = True
for expect in _CHAIN_IDS:
if q + 3 > len(body) or body[q + 2] != expect:
ok = False
break
length = int.from_bytes(body[q:q + 2], "big")
recs.append((q, expect, length))
q = q + 2 + length
if ok and len(recs) == 4:
return recs
return None
def decode_sensor_check(raw: bytes) -> Dict[str, List[int]]:
"""Decode the four sensor self-check traces from a series-3 event binary.
Returns ``{"Tran": [...], "Vert": [...], "Long": [...], "MicL": [...]}`` in
raw decode units (same 16-count LSB as the main waveform), or ``{}`` if the
binary carries no sensor-check block (a histogram event, a non-series-3
file, or a unit/firmware that doesn't store it).
"""
strt = raw.find(b"STRT")
if strt < 0 or len(raw) < strt + 21 + 26:
return {}
body = raw[strt + 21: len(raw) - 26]
chain = _find_chain(body)
if not chain:
return {}
out: Dict[str, List[int]] = {}
for off, rid, length in chain:
payload = body[off + 2: off + 2 + length]
if len(payload) < _HEADER_LEN + _TRAILER_LEN:
continue
stream = payload[_HEADER_LEN: length - _TRAILER_LEN]
out[_ID_TO_CHANNEL[rid]] = _decode_delta_stream(stream)
return out
+7 -44
View File
@@ -722,18 +722,7 @@ STREAM_END_ID = 0x06
MODE_DELTA = (0x02, 0x00)
MODE_ABSOLUTE = (0x01, 0x00)
MODE_RAW12 = (0x00, 0x03)
# Raw int16 BE absolute samples, 10-byte header, no tags — the same shape as
# MODE_RAW12 but two bytes per sample instead of 1.5. Found on Thor/Micromate
# segment-0 records (2026-09-10): a `len=1032` record carries exactly
# (1032 - 8) / 2 = 512 samples and reproduces Thor's own export 512/512
# exactly. Before this mode existed the record fell through the dispatch
# unhandled, so the channel silently lost its first 512 samples.
MODE_RAW16 = (0x00, 0x00)
_MODES = (MODE_DELTA, MODE_ABSOLUTE, MODE_RAW12, MODE_RAW16)
# Preambles whose leading data is untagged and therefore cannot be
# block-walked; find_first_record() must scan for the next record instead.
_UNTAGGED_MODES = (MODE_RAW12, MODE_RAW16)
_MODES = (MODE_DELTA, MODE_ABSOLUTE, MODE_RAW12)
def _u16(b: bytes, p: int) -> int:
@@ -758,18 +747,7 @@ def data_block_len(body: bytes, p: int) -> Tuple[Optional[int], Optional[int]]:
hi = t0 & 0xF0
nn = ((t0 & 0x0F) << 8) | t1
if hi == 0x40: # int16 BE data block
# NN was capped at 0x08 until 2026-09-11. That cap had no basis: the
# two corpora available at the time only ever used NN in {1,2,3,4,8},
# so it was never exercised. Loud UM12947 events use NN of 12, 16,
# 20 ... up to 196, and every value above 8 halted the walk, which
# surfaced as silently short channels (walk_body/run stop at the first
# unrecognised tag rather than raising). Verified against Thor's own
# exports: 22 length-mismatched files -> 0, and the affected corpus
# went to 1,476,242/1,476,249 samples exact. The real bound is the
# buffer; the caller additionally clamps to the record end.
if nn == 0 or p + 2 * nn + 2 > len(body):
return None, None
return 2 * nn + 2, nn
return (None, None) if (nn == 0 or nn > 0x08) else (2 * nn + 2, nn)
if nn == 0 or nn % 4:
return None, None
if hi == 0x00:
@@ -783,11 +761,6 @@ def data_block_len(body: bytes, p: int) -> Tuple[Optional[int], Optional[int]]:
return None, None
def unpack16(data: bytes) -> List[int]:
"""Raw int16 BE absolute samples (MODE_RAW16)."""
return [_i16(data, 2 * k) for k in range(len(data) // 2)]
def unpack12(data: bytes) -> List[int]:
"""Raw 12-bit packed samples: 6 bytes -> 4 signed values."""
out: List[int] = []
@@ -812,17 +785,13 @@ def find_first_record(body: bytes) -> Optional[int]:
"""Offset of the first record, or None.
Under the normal ``00 02 00`` preamble the leading bytes are segment-0's
Tran blocks, so walk them. Under the untagged preambles (``00 00 03``
raw-12 and ``00 00 00`` raw-16) that data has no tags at all and cannot
be block-walked — scan for the next record header instead.
Tran blocks, so walk them. Under the ``00 00 03`` preamble that data is
raw 12-bit with no tags at all and cannot be block-walked — scan instead.
"""
if len(body) >= 3 and (body[1], body[2]) in _UNTAGGED_MODES:
if len(body) >= 3 and (body[1], body[2]) == MODE_RAW12:
scan_from = 3
else:
# Tagged preamble. MODE_DELTA carries a 14-byte record header (two
# int16 anchors), so its blocks start at body[7]; MODE_ABSOLUTE has a
# 10-byte header and starts at body[3].
i = 3 if (len(body) >= 3 and (body[1], body[2]) == MODE_ABSOLUTE) else 7
i = 7
while i < len(body):
if is_record(body, i):
nxt = i + 2 + _u16(body, i + 2)
@@ -881,7 +850,7 @@ def decode_waveform_v2(body: bytes) -> Optional[dict]:
if len(body) < 8 or body[0] != 0x00:
return None
preamble = (body[1], body[2])
if preamble not in (MODE_DELTA, MODE_ABSOLUTE, MODE_RAW12, MODE_RAW16):
if preamble not in (MODE_DELTA, MODE_RAW12):
return None
first = find_first_record(body)
if first is None:
@@ -926,10 +895,6 @@ def decode_waveform_v2(body: bytes) -> Optional[dict]:
if preamble == MODE_DELTA:
out["Tran"].extend([_i16(body, 3), _i16(body, 5)])
run("Tran", 7, first, absolute=False)
elif preamble == MODE_ABSOLUTE:
run("Tran", 3, first, absolute=True)
elif preamble == MODE_RAW16:
out["Tran"].extend(unpack16(body[3:first]))
else:
out["Tran"].extend(unpack12(body[3:first]))
@@ -943,6 +908,4 @@ def decode_waveform_v2(body: bytes) -> Optional[dict]:
run(ch, off + 10, end, absolute=True)
elif mode == MODE_RAW12:
out[ch].extend(unpack12(body[off + 10:end]))
elif mode == MODE_RAW16:
out[ch].extend(unpack16(body[off + 10:end]))
return out
+1 -1
View File
@@ -4,7 +4,7 @@ build-backend = "setuptools.build_meta"
[project]
name = "seismo-relay"
version = "0.31.0"
version = "0.29.0"
description = "Python client and REST server for MiniMate Plus seismographs"
requires-python = ">=3.10"
dependencies = [
-33
View File
@@ -1,33 +0,0 @@
"""Pretend to be a Micromate on a serial port: log what arrives, reply to POLL.
Proves the modem's return path (serial -> TCP) independently of the real unit.
"""
import os, select, sys, termios, time
path, baud = sys.argv[1], int(sys.argv[2]) if len(sys.argv) > 2 else 115200
B = {9600: termios.B9600, 38400: termios.B38400, 115200: termios.B115200}[baud]
fd = os.open(path, os.O_RDWR | os.O_NOCTTY | os.O_NONBLOCK)
a = termios.tcgetattr(fd)
a[0] = a[1] = a[3] = 0
a[2] = termios.CS8 | termios.CREAD | termios.CLOCAL
a[4] = a[5] = B
a[6] = list(a[6]); a[6][termios.VMIN] = 0; a[6][termios.VTIME] = 0
termios.tcsetattr(fd, termios.TCSANOW, a)
termios.tcflush(fd, termios.TCIOFLUSH)
# A real POLL probe reply, captured from UM12947 on 2026-09-24.
REPLY = bytes.fromhex("0200c5a4000000000000300000000000000099") + b"\x03"
print(f"fake unit on {path} @ {baud}; will answer any inbound frame", flush=True)
while True:
r, _, _ = select.select([fd], [], [], 1.0)
if not r:
continue
data = os.read(fd, 4096)
if not data:
continue
ts = time.strftime("%H:%M:%S")
print(f"{ts} IN {len(data):3} B {data.hex(' ')}", flush=True)
time.sleep(0.02)
os.write(fd, REPLY)
print(f"{ts} OUT {len(REPLY):3} B {REPLY.hex(' ')} <- canned POLL reply", flush=True)
-368
View File
@@ -1,368 +0,0 @@
#!/usr/bin/env python3
"""mm_config_diff.py — snapshot a Micromate's config blocks and diff them.
**Read-only.** Sends only the five config reads plus POLL/SERIAL. It never
writes, never erases, never starts or stops monitoring.
Why it exists
-------------
`docs/micromate_protocol_reference.md` has about a dozen fields read out of
`SUB 0x1A` (2,103 bytes) and *nothing* out of `0x2C`, `0x2E`, `0x08` or `0x01`.
They are fetched and undecoded. The method that mapped the Series III config
was a diff loop: change exactly one setting, re-read, see which bytes moved.
This is that loop for Series IV.
The one thing that loop needs first
-----------------------------------
**Which bytes move on their own.** A config block read twice, thirty seconds
apart, with nothing touched, is not byte-identical — it carries a clock, a free
-memory figure and at least one counter. Diff two snapshots taken either side
of a setting change and those bytes show up alongside the real answer, and
there is no way to tell which is which from a single pair.
So `volatile` runs first: N reads back to back, nothing changed, and every byte
that differs is recorded as noise. `diff` then reports the two sets
separately. Without that baseline a diff is suggestive; with it, it is
evidence.
Usage
-----
# establish the noise floor FIRST -- nothing touched between reads
python3 scratch/mm_config_diff.py /dev/ttyACM0 volatile -n 4
# baseline, then change ONE setting on the unit's keypad, then:
python3 scratch/mm_config_diff.py /dev/ttyACM0 snap before
python3 scratch/mm_config_diff.py /dev/ttyACM0 snap after-rectime-4s
python3 scratch/mm_config_diff.py /dev/ttyACM0 diff before after-rectime-4s
Snapshots live in `scratch/mm_config_snaps/<serial>/<label>/`, which is
gitignored like the other capture artefacts.
"""
from __future__ import annotations
import argparse
import json
import struct
import sys
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from bridges.mm_client_check import StdlibSerial # noqa: E402
from micromate.client import MicromateClient # noqa: E402
from micromate.setup_block import crc_ok # noqa: E402
from minimateplus.transport import TcpTransport # noqa: E402
SNAP_ROOT = Path(__file__).resolve().parent / "mm_config_snaps"
# Content starts at data[11]; the reference documents fields as content[N], so
# every changed offset is reported both ways to save a subtraction per finding.
CONTENT = 11
# Block name -> the protocol method that reads it. 0x1C is included on purpose:
# it is the one block whose volatility is already known (it carries the clock),
# so it doubles as a positive control that the volatile pass is working.
# Bytes that are KNOWN volatile from the field layout, seeded regardless of
# whether they happened to move during the sample window. An empirical noise
# floor only catches what moves WHILE sampling: a four-read pass over eight
# seconds sees the sub-second tick and the seconds byte and silently misses
# minutes, hours and the date, which then surface later as fake "findings".
# 0x1C content[2:10] is day/month/year/tick/hour/min/sec; content starts at 11.
# Memory-free (content[40:44]) is deliberately NOT masked -- it moves only when
# the unit actually records, which is a thing worth being told about.
KNOWN_VOLATILE = {
"1C_monitor_status": list(range(11 + 2, 11 + 10)),
}
BLOCKS = {
"1A_compliance": "read_compliance_config",
"2C_call_home": "read_call_home_config",
"2E_trigger": "read_trigger_config",
"08_event_index": "read_event_index",
"01_device_info": "read_device_info",
"1C_monitor_status": "read_monitor_status",
}
def _open(target: str, timeout: float):
if ":" in target and not target.startswith("/"):
host, _, port = target.rpartition(":")
return TcpTransport(host, int(port))
return StdlibSerial(target, baud=115200)
def read_all(mm: MicromateClient) -> dict[str, bytes]:
out = {}
for name, meth in BLOCKS.items():
try:
out[name] = bytes(getattr(mm._proto, meth)())
except Exception as e: # noqa: BLE001
print(f" {name}: FAILED {type(e).__name__}: {e}")
return out
def save(serial: str, label: str, blocks: dict[str, bytes]) -> Path:
d = SNAP_ROOT / serial / label
d.mkdir(parents=True, exist_ok=True)
for name, raw in blocks.items():
(d / f"{name}.bin").write_bytes(raw)
(d / "meta.json").write_text(json.dumps({
"serial": serial,
"label": label,
"taken": time.strftime("%Y-%m-%dT%H:%M:%S"),
"sizes": {k: len(v) for k, v in blocks.items()},
}, indent=2))
return d
def load(serial: str, label: str) -> dict[str, bytes]:
d = SNAP_ROOT / serial / label
if not d.is_dir():
sys.exit(f"no snapshot '{label}' for {serial} (looked in {d})")
return {p.stem: p.read_bytes() for p in sorted(d.glob("*.bin"))}
def _interps(a: bytes, b: bytes, off: int, run: int) -> list[str]:
"""How a changed run reads under each plausible field type."""
out = [f"u8 {a[off]:3d} -> {b[off]:3d}"]
if run <= 2 and off + 2 <= len(a):
x, y = struct.unpack_from(">H", a, off)[0], struct.unpack_from(">H", b, off)[0]
out.append(f"u16be {x} -> {y}")
if run <= 4 and off + 4 <= len(a):
x, y = struct.unpack_from(">I", a, off)[0], struct.unpack_from(">I", b, off)[0]
out.append(f"u32be {x} -> {y}")
fx, fy = struct.unpack_from(">f", a, off)[0], struct.unpack_from(">f", b, off)[0]
if all(abs(v) < 1e9 and (v == 0 or abs(v) > 1e-6) for v in (fx, fy)):
out.append(f"f32be {fx:g} -> {fy:g}")
return out
# Blocks that carry the config checksum (micromate.setup_block.crc_ok): N =
# content[0:2], CRC-16/AUG-CCITT over [0:N-2] stored at [N:N+2]. 0x2C has none.
CRC_BLOCKS = {"1A_compliance", "08_event_index", "2E_trigger"}
def crc_status(raw: bytes) -> str:
"""A mismatch means a short or corrupt read -- or a block this rule misses."""
c = raw[CONTENT:]
stored = c[int.from_bytes(c[0:2], "big"):][:2].hex() if len(c) >= 2 else "--"
return f"CRC ok ({stored})" if crc_ok(c) else f"CRC MISMATCH (stored {stored})"
def _runs(a: bytes, b: bytes, ignore: set[int]) -> list[tuple[int, int]]:
"""Contiguous runs of differing offsets, skipping known-volatile ones."""
diff = [i for i in range(min(len(a), len(b)))
if a[i] != b[i] and i not in ignore]
runs, start = [], None
for i, off in enumerate(diff):
if start is None:
start = off
if i + 1 == len(diff) or diff[i + 1] != off + 1:
runs.append((start, off - start + 1))
start = None
return runs
def cmd_volatile(mm: MicromateClient, serial: str, n: int) -> None:
print(f"\n{n} reads back to back, nothing touched between them.")
print("Every byte that moves here is noise and must be excluded from a diff.\n")
snaps = []
for i in range(n):
print(f" read {i + 1}/{n} ...", end="", flush=True)
snaps.append(read_all(mm))
print(" ok")
if i + 1 < n:
time.sleep(2.0)
volatile: dict[str, list[int]] = {}
for name in snaps[0]:
moved = set()
for later in snaps[1:]:
if name not in later:
continue
a, b = snaps[0][name], later[name]
if len(a) != len(b):
print(f" {name}: LENGTH CHANGED {len(a)} -> {len(b)} -- that is itself a finding")
moved |= {i for i in range(min(len(a), len(b))) if a[i] != b[i]}
volatile[name] = sorted(moved | set(KNOWN_VOLATILE.get(name, [])))
print()
for name, offs in volatile.items():
size = len(snaps[0][name])
seeded = set(KNOWN_VOLATILE.get(name, []))
observed = set(offs) - seeded
if not offs:
print(f" {name:20s} {size:5d} B STABLE -- every byte held still")
else:
note = f"{len(observed)} observed"
if seeded:
note += f" + {len(seeded)} seeded from the known clock layout"
print(f" {name:20s} {size:5d} B {len(offs):4d} volatile ({note})")
print(f" {'':20s} {offs[:20]}" + (" ..." if len(offs) > 20 else ""))
out = SNAP_ROOT / serial / "volatile.json"
out.parent.mkdir(parents=True, exist_ok=True)
out.write_text(json.dumps(volatile, indent=2))
print(f"\nwrote {out}")
print("`diff` reads this automatically and reports noise separately.")
def cmd_diff(serial: str, a_label: str, b_label: str) -> None:
A, B = load(serial, a_label), load(serial, b_label)
vpath = SNAP_ROOT / serial / "volatile.json"
vol = json.loads(vpath.read_text()) if vpath.is_file() else {}
if not vol:
print("⚠ no volatile.json -- run `volatile` first, or every clock tick")
print(" below will look like a config field.\n")
for name in sorted(set(A) & set(B)):
a, b = A[name], B[name]
ignore = set(vol.get(name, []))
if len(a) != len(b):
print(f"\n{name}: LENGTH {len(a)} -> {len(b)} (a length change is a finding)")
runs = _runs(a, b, ignore)
noise = sum(1 for i in range(min(len(a), len(b)))
if a[i] != b[i] and i in ignore)
if not runs:
tail = f" ({noise} volatile bytes ignored)" if noise else ""
print(f"\n{name:20s} no non-volatile change{tail}")
continue
print(f"\n{name} — {len(runs)} changed run(s)"
+ (f", {noise} volatile bytes ignored" if noise else ""))
for off, run in runs:
print(f" @{off:5d} (0x{off:04x}) content[{off - CONTENT:d}] {run} B "
f"{a[off:off + run].hex()} -> {b[off:off + run].hex()}")
for line in _interps(a, b, off, run):
print(f" {line}")
def cmd_watch(mm: MicromateClient, serial: str, interval: float,
duration: float, prefix: str | None = None) -> None:
"""Poll the config blocks and report each change as it lands.
A round trip per setting means walking to the unit and back for every
field. This instead lets one person stand at the keypad changing settings
one at a time while every change is timestamped here, so a whole session is
one pass. Each distinct state is also saved as `<prefix>-NNN`, so the
sequence can be re-diffed offline afterwards without the unit.
The prefix defaults to `watch-MMDD-HHMM`, i.e. one per session. It used to
be a fixed `watch-`, so every run silently overwrote the previous run's
snapshots -- harmless while they were clock ticks, data loss once they
were findings.
"""
prefix = prefix or time.strftime("watch-%m%d-%H%M")
vpath = SNAP_ROOT / serial / "volatile.json"
vol = json.loads(vpath.read_text()) if vpath.is_file() else {}
if not vol:
print("⚠ no volatile.json -- run `volatile` first.\n")
print(f"watching every {interval:g}s"
+ (f" for {duration:g}s" if duration else " until Ctrl-C"))
print("change ONE setting at a time on the unit's keypad; each change is")
print(f"timestamped below and saved as {prefix}-NNN.\n")
prev = read_all(mm)
save(serial, f"{prefix}-000", prev)
print(f"[{time.strftime('%H:%M:%S')}] baseline captured ({prefix}-000)")
for k, v in sorted(prev.items()):
print(f" {k:20s} {len(v):5d} B")
print()
n, t0 = 0, time.monotonic()
try:
while not duration or time.monotonic() - t0 < duration:
time.sleep(interval)
cur = read_all(mm)
hits = []
for name in sorted(set(prev) & set(cur)):
a, b = prev[name], cur[name]
ignore = set(vol.get(name, []))
if len(a) != len(b):
hits.append((name, None, len(a), len(b)))
continue
runs = _runs(a, b, ignore)
if runs:
hits.append((name, runs, None, None))
if not hits:
continue
n += 1
label = f"{prefix}-{n:03d}"
save(serial, label, cur)
print(f"[{time.strftime('%H:%M:%S')}] CHANGE #{n} ({label})")
for name, runs, la, lb in hits:
if runs is None:
print(f" {name}: LENGTH {la} -> {lb} (a length change is a finding)")
continue
print(f" {name} — {len(runs)} run(s)")
for off, run in runs:
a, b = prev[name], cur[name]
print(f" @{off:5d} (0x{off:04x}) content[{off - CONTENT:d}] {run} B "
f"{a[off:off + run].hex()} -> {b[off:off + run].hex()}")
for line in _interps(a, b, off, run):
print(f" {line}")
if name in CRC_BLOCKS:
print(f" {crc_status(cur[name])}")
print(flush=True)
prev = cur
except KeyboardInterrupt:
print("\nstopped.")
print(f"{n} change(s) recorded; snapshots {prefix}-000..{prefix}-{n:03d} under")
print(f" {SNAP_ROOT / serial}")
def main() -> int:
p = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
p.add_argument("target", help="/dev/ttyACM0 or host:port")
p.add_argument("--timeout", type=float, default=10.0)
sub = p.add_subparsers(dest="cmd", required=True)
s = sub.add_parser("snap", help="read all blocks and save under a label")
s.add_argument("label")
v = sub.add_parser("volatile", help="find bytes that move with nothing changed")
v.add_argument("-n", type=int, default=4)
w = sub.add_parser("watch", help="poll and report each change as it lands")
w.add_argument("--interval", type=float, default=2.0)
w.add_argument("--duration", type=float, default=0.0, help="0 = until Ctrl-C")
w.add_argument("--prefix", help="snapshot label prefix (default: watch-MMDD-HHMM)")
d = sub.add_parser("diff", help="diff two saved snapshots")
d.add_argument("a")
d.add_argument("b")
d.add_argument("--serial", help="override (default: read from the unit)")
a = p.parse_args()
# `diff` is pure offline work on saved files -- do not touch the unit for it.
if a.cmd == "diff" and a.serial:
cmd_diff(a.serial, a.a, a.b)
return 0
transport = _open(a.target, a.timeout)
mm = MicromateClient(transport, recv_timeout=a.timeout)
mm.open() # opens the port; connect() only handshakes
info = mm.connect()
serial = info.serial or "unknown"
print(f"{serial} {info.model} fw={info.firmware_line} "
f"setup={info.active_setup} monitoring={info.monitoring}")
try:
if a.cmd == "snap":
blocks = read_all(mm)
d = save(serial, a.label, blocks)
print(f"\nsaved {len(blocks)} blocks -> {d}")
for k, v2 in sorted(blocks.items()):
print(f" {k:20s} {len(v2):5d} B")
elif a.cmd == "volatile":
cmd_volatile(mm, serial, a.n)
elif a.cmd == "watch":
cmd_watch(mm, serial, a.interval, a.duration, a.prefix)
elif a.cmd == "diff":
cmd_diff(serial, a.a, a.b)
finally:
mm.close()
return 0
if __name__ == "__main__":
raise SystemExit(main())
-223
View File
@@ -1,223 +0,0 @@
#!/usr/bin/env python3
"""
mm_frame_parse.py — parse Micromate (Series IV) frames out of a seismo_lab
raw capture pair.
Why this exists
---------------
`minimateplus.framing.S3FrameParser` cannot see Micromate traffic. It locates
frames by scanning for `DLE STX`, and a Micromate response has **no leading
DLE** — it starts at a bare `STX`. It also expects `payload[1] == 0x10`, where
the Micromate sends `0xC5` (Blastware firmware) or `0x03` (Thor firmware).
The practical consequence, seen on the 9-24-26 setup-push capture: the
Blastware-side requests parse fine (Thor emits Series III request frames), but
**every device response is silently dropped or mis-framed** — so a capture that
actually contains 12 acked writes looks like 12 unanswered requests.
Destuffing
----------
One rule covers both directions: after the leading doubled `BW_CMD`, every
`10 XX` pair on the wire destuffs to `XX`. That includes `10 03` — Thor
escapes literal `0x03` bytes in write data so they are not mistaken for ETX,
exactly as Blastware does.
A Micromate escapes exactly four byte values — `0x02 0x03 0x04 0x10` — and
nothing else, which is what makes the uniform rule exact rather than merely
convenient. Established by re-stuffing all 502 captured frames and comparing
to the wire: 251/251 each direction, where `{0x10}` alone gets 130 and 177.
⚠ Checksum, corrected 2026-09-27
--------------------------------
With uniform destuffing the checksum is **plain SUM8 of the destuffed
payload**. This script used to try SUM8 *and* a "DLE-aware" variant that
excludes `0x10` bytes, and report whichever matched — which is why it never
flagged a bad frame and why the protocol reference carried the wrong rule for
two days. The DLE-aware form belongs with *Series III* destuffing, where an
escaped byte survives as two bytes; applying it after uniform destuffing
subtracts the correction twice and disagrees with the wire on 55 of 251
responses.
The lesson generalises: a tool that accepts any of N candidate rules cannot
falsify any of them. It now validates against SUM8 alone, and reports
`DLE-aware` only to name what a mismatch *would* have been — never as a pass.
See `docs/micromate_protocol_reference.md` → *Checksum*, and
`tests/test_micromate_framing.py`, which pins it.
`micromate/framing.py` is the production implementation; this stays as the
one-shot capture-inspection tool.
Usage
-----
python scratch/mm_frame_parse.py <capture-dir>
python scratch/mm_frame_parse.py <raw_bw.bin> <raw_s3.bin>
python scratch/mm_frame_parse.py <capture-dir> --dump 0x71
"""
from __future__ import annotations
import argparse
import sys
from pathlib import Path
DLE, STX, ETX, ACK = 0x10, 0x02, 0x03, 0x41
# Request SUB -> short name. Series III names where they carry over; the
# Series IV additions are marked.
SUBNAME = {
0x01: "DEVICE_INFO",
0x06: "STORAGE_RANGE",
0x08: "EVENT_INDEX",
0x0A: "WAVEFORM_HDR",
0x0C: "WAVEFORM_REC",
0x15: "SERIAL",
0x1A: "COMPLIANCE_CFG",
0x1C: "MONITOR_STATUS",
0x1E: "EVENT_HDR",
0x2C: "CALLHOME_CFG",
0x2E: "TRIGGER_CFG_READ", # Series IV
0x3E: "OPERATOR",
0x41: "SETUP_NAME_READ", # Series IV
0x5A: "BULK_DOWNLOAD",
0x5B: "POLL",
0x68: "EVENT_INDEX_WRITE",
0x69: "WAVEFORM_WRITE",
0x71: "COMPLIANCE_WRITE",
0x72: "CONFIRM_A",
0x73: "CONFIRM_B",
0x74: "CONFIRM_C",
0x82: "TRIGGER_WRITE",
0x83: "TRIGGER_CONFIRM",
0xDA: "SETUP_FILE_DECL", # Series IV — names the target .MMB
0xFE: "FULL_CFG",
}
def destuff(blob: bytes, start: int, *, is_request: bool) -> tuple[bytes, int, int]:
"""Destuff one frame starting at `start`.
Returns (payload, checksum, index_of_terminating_ETX). `payload` excludes
the trailing checksum byte. A request frame opens `ACK STX 10 10`; a
response opens with a bare `STX`.
"""
i = start + (2 if is_request else 1)
out = bytearray()
if is_request:
# The doubled BW_CMD is the one guaranteed stuffed byte.
if blob[i : i + 2] != bytes([DLE, DLE]):
raise ValueError(f"@0x{start:04x}: request does not open with 10 10")
out.append(DLE)
i += 2
while i < len(blob):
b = blob[i]
if b == DLE and i + 1 < len(blob):
out.append(blob[i + 1])
i += 2
continue
if b == ETX:
break
out.append(b)
i += 1
if len(out) < 2:
raise ValueError(f"@0x{start:04x}: frame too short")
return bytes(out[:-1]), out[-1], i
def frames(blob: bytes, *, is_request: bool):
"""Yield (offset, payload, chk, checksum_kind)."""
i, n = 0, len(blob)
while i < n:
if is_request:
if not (blob[i] == ACK and i + 1 < n and blob[i + 1] == STX):
i += 1
continue
elif blob[i] != STX:
i += 1
continue
try:
payload, chk, end = destuff(blob, i, is_request=is_request)
except ValueError:
i += 1
continue
# SUM8 of the destuffed payload is THE rule -- 502/502 captured frames.
# The DLE-aware variant is reported only to name a near-miss; it is
# never a pass. See the module docstring.
if (sum(payload) & 0xFF) == chk:
kind = "ok"
elif (sum(b for b in payload if b != DLE) & 0xFF) == chk:
kind = "BAD(dle-aware)"
else:
kind = "BAD"
yield i, payload, chk, kind
i = end + 1
def describe(payload: bytes, is_request: bool) -> str:
if len(payload) < 3:
return "??"
sub = payload[2]
if is_request:
return SUBNAME.get(sub, f"SUB_{sub:02X}")
req = 0xFF - sub
return "rsp<-" + SUBNAME.get(req, f"SUB_{req:02X}")
def report(path: Path, *, is_request: bool, dump_sub: int | None) -> None:
blob = path.read_bytes()
side = "Thor" if is_request else "unit"
print(f"== {side:4} {path.name} ({len(blob)} bytes)")
n_bad = 0
for idx, (off, p, chk, kind) in enumerate(frames(blob, is_request=is_request)):
if kind == "BAD":
n_bad += 1
sub = p[2] if len(p) > 2 else -1
flags = p[1] if len(p) > 1 else -1
# Requests carry offset at payload[4:6]; responses page at [3:5].
word = int.from_bytes(p[4:6] if is_request else p[3:5], "big")
data = len(p) - 16 if is_request else max(len(p) - 5, 0)
print(
f" [{idx:2}] @0x{off:04x} payload={len(p):5} data={data:5} "
f"flags=0x{flags:02x} SUB=0x{sub:02x} {describe(p, is_request):18} "
f"{'offset' if is_request else 'page'}=0x{word:04x} chk={kind}"
)
if dump_sub is not None and sub == dump_sub:
body = p[16:] if is_request else p[5:]
print(f" ---- data ({len(body)} bytes) ----")
for o in range(0, len(body), 16):
chunk = body[o : o + 16]
txt = "".join(chr(c) if 32 <= c < 127 else "." for c in chunk)
print(f" {o:06x} {chunk.hex(' '):<47} |{txt}|")
print(f" -- {idx + 1} frames, {n_bad} bad checksum\n")
def main() -> int:
ap = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
ap.add_argument("paths", nargs="+",
help="a capture directory, or raw_bw.bin and raw_s3.bin")
ap.add_argument("--dump", default=None,
help="hex-dump the data section of this SUB (e.g. 0x71)")
args = ap.parse_args()
dump_sub = int(args.dump, 0) if args.dump else None
if len(args.paths) == 1 and Path(args.paths[0]).is_dir():
d = Path(args.paths[0])
bw = sorted(d.glob("raw_bw_*.bin"))
s3 = sorted(d.glob("raw_s3_*.bin"))
if not bw or not s3:
print(f"{d}: need one raw_bw_*.bin and one raw_s3_*.bin", file=sys.stderr)
return 2
pairs = [(bw[0], True), (s3[0], False)]
elif len(args.paths) == 2:
pairs = [(Path(args.paths[0]), True), (Path(args.paths[1]), False)]
else:
ap.error("pass a capture directory, or exactly two .bin files")
for path, is_request in pairs:
report(path, is_request=is_request, dump_sub=dump_sub)
return 0
if __name__ == "__main__":
sys.exit(main())
-228
View File
@@ -1,228 +0,0 @@
#!/usr/bin/env python3
"""
mm_stream_probe.py — how many bytes will `SUB 0x5A` serve in one request?
Settled 2026-10-02: there is NO streaming mode
----------------------------------------------
This script started out asking whether `offset_hi = 0x10` meant "stream until
done", because our 2026-09-23 notes recorded a single request appearing to return
an entire 11 KB event. Measured directly on UM20147, it does not:
offset 0x1014 (4116) -> one frame, 4127 B data, 4116 B of file
offset 0x111c (4380) -> one frame, 4391 B data, 4380 B of file
**`offset` is simply a byte count**, and the device returns exactly `offset + 11`
bytes in one frame. `0x1000` is not a marker; it is part of the number. The
2026-09-23 reading was wrong, and the protocol reference now says so.
The useful question it turned up
-------------------------------
**1024 bytes per request is THOR's choice, not the device's limit.** The unit
served 4,380 bytes in a single frame without being asked twice. Since a round
trip over cellular costs ~0.65 s regardless of payload, and UM20147's
72,560-byte event is 71 chunks ≈ 46 seconds, the ceiling on one request is worth
knowing precisely: every doubling halves the dominant cost.
So this now walks ascending request sizes against one event and **checks each
against a known-good chunk-loop download** — a pass means byte-identical output,
not merely a plausible length. The offset field is a uint16, so 65,535 is the
structural maximum.
⚠ **Read-only.** `0x5A` is a read we have sent thousands of times; the only new
thing is a larger value in its offset field. Nothing here writes, erases or
changes monitoring state. It re-POLLs at the end, because the honest risk is
leaving the session in an odd state and the script should say so.
Usage
-----
python3 scratch/mm_stream_probe.py /dev/ttyACM1
python3 scratch/mm_stream_probe.py /dev/ttyACM1 --event largest
"""
from __future__ import annotations
import argparse
import math
import sys
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
sys.path.insert(0, str(Path(__file__).resolve().parent.parent / "bridges"))
from micromate.client import MicromateClient, _content # noqa: E402
from micromate.framing import MicromateFrameParser, build_request # noqa: E402
from micromate.protocol import SUB_BULK_DOWNLOAD, THOR_CHUNK_SIZE # noqa: E402
from mm_client_check import StdlibSerial # noqa: E402
from minimateplus.transport import TcpTransport # noqa: E402
_CHUNK_PREFIX = 11
def collect(transport, parser, *, idle_gap: float, deadline: float) -> list:
"""Read until `idle_gap` seconds pass with no new bytes, or `deadline`."""
frames, last = [], time.monotonic()
while time.monotonic() < deadline:
chunk = transport.read(4096)
if chunk:
frames += parser.feed(chunk)
last = time.monotonic()
continue
if time.monotonic() - last > idle_gap:
break
time.sleep(0.005)
return frames
def main() -> int:
ap = argparse.ArgumentParser(
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
)
ap.add_argument("target", help="host:port, or a serial device path")
ap.add_argument("--baud", type=int, default=115200)
ap.add_argument("--event", default="smallest",
help="a key in hex, 'smallest' (default — the gentlest "
"first test) or 'largest' (the one that matters)")
ap.add_argument("--idle-gap", type=float, default=3.0,
help="seconds of silence that end a read. A 16 KB response "
"is ~1.4 s of serial time at 115200 BEFORE the modem's "
"~1 s forwarding delay, so this is deliberately roomy; "
"too small and a slow link looks like a clamp.")
ap.add_argument("--timeout", type=float, default=90.0)
a = ap.parse_args()
if ":" in a.target and not Path(a.target).exists():
host, _, port = a.target.rpartition(":")
inner = TcpTransport(host, int(port), connect_timeout=10.0)
label = f"TCP {host}:{port}"
else:
inner = StdlibSerial(a.target, baud=a.baud)
label = f"serial {a.target} @ {a.baud}"
mm = MicromateClient(inner, recv_timeout=20.0)
print(f"\n{label} READ-ONLY: chain walk + two downloads of one event\n")
mm.open()
try:
info = mm.connect(with_active_setup=False)
print(f" {info}\n")
refs = mm.list_events()
if not refs:
print(" no events stored — nothing to download. Record one first.")
return 1
for r in refs:
print(f" {r}")
which = a.event.strip().lower()
if which == "smallest":
ref = min(refs, key=lambda r: r.size)
elif which == "largest":
ref = max(refs, key=lambda r: r.size)
else:
matches = [r for r in refs if r.key_hex.lower() == which]
if not matches:
print(f"\n --event {a.event!r} matched nothing")
return 2
ref = matches[0]
n_chunks = math.ceil(ref.size / THOR_CHUNK_SIZE)
print(f"\n target: {ref.key_hex} {ref.size} B {ref.record_type} "
f"({n_chunks} requests at THOR's chunk size)")
# ── 1. the control: THOR's 1024-byte chunk loop ───────────────────────
# ⚠ Pinned to THOR_CHUNK_SIZE on purpose. The library default is now
# 16,384, and using it here would make the experiment circular -- the
# "known-good" reference would share any fault with the sizes under test.
# 1024 is the size with THOR's own captures behind it and the one proven
# over a modem, so it is the control.
t0 = time.monotonic()
chunked = mm.protocol.read_event_file(ref.key, ref.size,
chunk_size=THOR_CHUNK_SIZE)
dt_chunked = time.monotonic() - t0
print(f"\n [1] control ......... {len(chunked)} B in {dt_chunked:.2f} s "
f"({n_chunks} requests at THOR's 1024 B)")
# ── 2. how many bytes will it serve in ONE frame? ─────────────────
# The streaming hypothesis is dead (see the module docstring): `offset`
# is simply a BYTE COUNT, and the device returns `offset + 11` bytes in
# one frame. So the real question is the ceiling -- because 1024 is
# THOR's choice, not the device's limit, and every doubling halves the
# round trips that dominate a cellular download.
print("\n [2] chunk-size ceiling — ascending single requests")
print(" each asks for N bytes from offset 0 and is checked against")
print(" the known-good download, so a pass means identical bytes.\n")
candidates = [1024, 2048, 4096, 8192, 16384, 32768, 65535]
candidates = [n for n in candidates if n <= ref.size] or [ref.size]
if ref.size not in candidates and ref.size < 65536:
candidates.append(ref.size) # the whole event in one request
best = None
for n in candidates:
frame = build_request(SUB_BULK_DOWNLOAD, n, ref.key + bytes(6))
parser = MicromateFrameParser()
t0 = time.monotonic()
mm.protocol._send(frame)
got = collect(inner, parser, idle_gap=a.idle_gap,
deadline=t0 + a.timeout)
dt = time.monotonic() - t0
if not got:
print(f" {n:6} B no answer ({dt:.2f} s)")
continue
body = b"".join(f.data[_CHUNK_PREFIX:] for f in got)
ok = body == chunked[:n]
flag = "OK " if ok else "MISMATCH"
# ⚠ dt includes the idle gap: collect() waits `idle_gap` after the
# last byte before deciding the response is over. Subtract it to
# compare against the control, which reads to frame completion.
print(f" {n:6} B {len(got)} frame(s) {len(body):6} B back "
f"{dt:5.2f} s ({max(dt - a.idle_gap, 0):4.2f} s net) {flag}"
+ ("" if ok or not body else
f" (first diff at {next((i for i in range(min(len(body), n)) if body[i] != chunked[i]), None)})"))
if ok and len(body) == n:
best = n
print()
if best is None:
print(" VERDICT: nothing above the current chunk size verified.")
else:
now = math.ceil(ref.size / THOR_CHUNK_SIZE)
then = math.ceil(ref.size / best)
print(f" VERDICT: the device serves at least {best} B per request,")
print(f" verified byte-identical. For this {ref.size} B event that")
print(f" is {then} request(s) instead of {now}.")
if best > THOR_CHUNK_SIZE:
# ⚠ cost is ~0.21 s per request PLUS ~2,350 B/s over a modem --
# a download is throughput-bound, so do not promise a saving
# proportional to the drop in request count.
fixed, rate = 0.212, 2348.0
t_now = now * fixed + ref.size / rate
t_then = then * fixed + ref.size / rate
print(f" Modelled over cellular (0.21 s/request + "
f"{rate:.0f} B/s): {t_now:.1f} s -> {t_then:.1f} s, "
f"a {100 * (1 - t_then / t_now):.0f}% saving.")
print(" Throughput-bound, not round-trip bound — most of that is")
print(" bytes on the wire and batching does not touch it.")
if best >= ref.size:
print(" The WHOLE EVENT fits in one request.")
# ── 3. is the unit still healthy? ─────────────────────────────────────
# The real risk of this experiment is leaving the session wedged, so
# check rather than assume.
print()
try:
p = mm.protocol.poll()
print(f" [3] unit still answering POLL (SUB 0x{p.sub:02x}) — "
f"session is healthy")
except Exception as e:
print(f" [3] ⚠ POLL FAILED after the probe: {type(e).__name__}: {e}")
print(" Reconnect; if that does not help, power-cycle the unit.")
return 4
finally:
mm.close()
return 0
if __name__ == "__main__":
raise SystemExit(main())
-119
View File
@@ -1,119 +0,0 @@
#!/usr/bin/env python3
"""
socat_log_split.py — recover a capture pair from a `socat -x` relay log.
Why this exists
---------------
The bench relay that puts Thor in front of a USB-attached Micromate is:
socat -d -d -x TCP-LISTEN:12345,reuseaddr,fork /dev/ttyACM0,raw,echo=0,b115200 \
> ~/mm-captures/socat_<ts>.log 2>&1
`-x` makes socat hex-dump every byte it forwards, in both directions, with
timestamps. That log is therefore a **complete second copy of every capture**
taken through the relay — independent of whether seismo_lab was recording.
On 2026-09-25 that mattered: a capture's `.bin` files never made it off the
Windows machine, and the session was rebuilt from this log instead. When the
real bins turned up later, the reconstruction was **byte-for-byte identical in
both directions** (3,595 and 4,004 bytes). So this is a validated fallback, not
a lossy approximation.
Log format
----------
```
> 2026/09/25 00:30:35.000276659 length=21 from=0 to=20
41 02 10 10 00 5b 00 00 30 00 ...
2026/09/25 00:30:35 socat[32190] N write(5, 0x..., 21) completed
< 2026/09/25 00:30:35.000384100 length=64 from=0 to=63
02 00 c5 a4 00 00 30 00 ...
```
`>` is data heading toward the serial device (Thor → unit). `<` is data coming
back (unit → Thor). Hex lines are space-separated and indented; socat's own
status lines start with a date and carry no payload.
Usage
-----
# whole log
python scratch/socat_log_split.py socat_20260924_181248.log --out-dir ./recovered
# one session — line numbers from the "accepting connection" markers
grep -n "accepting connection" socat_*.log
python scratch/socat_log_split.py socat_*.log --from-line 919 --out-dir ./recovered
Then parse the result as usual:
python scratch/mm_frame_parse.py recovered/raw_bw.bin recovered/raw_s3.bin
⚠ A log spanning several sessions concatenates them. Split by line number using
the `accepting connection` markers, or the frame walk will run sessions together.
"""
from __future__ import annotations
import argparse
import re
from pathlib import Path
_HEX = re.compile(r"\A[0-9a-f]{2}\Z")
_SOCAT_STATUS = re.compile(r"\A\d{4}/\d{2}/\d{2}")
def split(lines) -> tuple[bytes, bytes]:
"""Return (to_device, from_device) byte streams."""
to_dev, from_dev = bytearray(), bytearray()
cur = None
for line in lines:
if line.startswith(">"):
cur = to_dev
continue
if line.startswith("<"):
cur = from_dev
continue
if _SOCAT_STATUS.match(line):
# socat's own status line ends the current dump block.
cur = None
continue
if cur is None or not line.startswith(" "):
continue
toks = line.split()
if toks and all(_HEX.match(t) for t in toks):
cur.extend(int(t, 16) for t in toks)
return bytes(to_dev), bytes(from_dev)
def main() -> int:
ap = argparse.ArgumentParser(
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
)
ap.add_argument("log", help="a socat -x log file")
ap.add_argument("--out-dir", default=".", help="where to write the .bin pair")
ap.add_argument("--from-line", type=int, default=1,
help="first log line to read (1-based) — use the "
"'accepting connection' marker of the session you want")
ap.add_argument("--to-line", type=int, default=None,
help="last log line to read (1-based, inclusive)")
ap.add_argument("--prefix", default="raw", help="output basename prefix")
args = ap.parse_args()
lines = Path(args.log).read_text(errors="replace").splitlines()
lo = max(args.from_line - 1, 0)
hi = args.to_line if args.to_line is not None else len(lines)
to_dev, from_dev = split(lines[lo:hi])
out = Path(args.out_dir)
out.mkdir(parents=True, exist_ok=True)
bw = out / f"{args.prefix}_bw.bin"
s3 = out / f"{args.prefix}_s3.bin"
bw.write_bytes(to_dev)
s3.write_bytes(from_dev)
print(f"Thor -> unit {len(to_dev):>7} bytes {bw}")
print(f"unit -> Thor {len(from_dev):>7} bytes {s3}")
if not to_dev or not from_dev:
print("⚠ one direction is empty — check --from-line / --to-line")
return 0
if __name__ == "__main__":
raise SystemExit(main())
-228
View File
@@ -1,228 +0,0 @@
#!/usr/bin/env python3
"""Verify the Thor / Micromate (series-4) IDF decoder against Thor's own exports.
Sister harness to ``scratch/verify_against_ascii.py`` (series-3 / Blastware).
Ground truth is the ``.IDFW.csv`` / ``.IDFH.csv`` file Thor writes next to each
binary, under a sibling ``CSV/`` directory:
<dir>/UM13981_20220207084555.IDFW
<dir>/CSV/UM13981_20220207084555.IDFW.csv
For waveforms the CSV carries a per-sample block of four columns
(Tran, Vert, Long, Mic) in in/s and psi -- i.e. true per-sample ground truth,
exactly what the BW ASCII exports give us for series-3. The leading 2-column
rows are the report header (PPV, sample rate, geo range, ...).
Usage:
python scratch/verify_thor_against_csv.py [--root DIR] [--lsb FLOAT]
[--limit N] [--kind idfw|idfh|both]
"""
from __future__ import annotations
import argparse
import csv
import os
import statistics
import sys
from collections import Counter, defaultdict
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from micromate import idf_file as M
DEFAULT_ROOT = "/home/serversdown/thor-watcher/example-data"
GEO = ("Tran", "Vert", "Long")
def parse_export(path):
"""Return (header_dict, sample_rows) from a Thor CSV export."""
hdr, rows = {}, []
with open(path, newline="", encoding="utf-8", errors="replace") as fh:
for rec in csv.reader(fh):
if len(rec) == 2:
hdr[rec[0].strip()] = rec[1].strip()
elif len(rec) >= 3:
try:
rows.append([float(x) for x in rec])
except ValueError:
pass
return hdr, rows
def index_corpus(root):
"""Map BASENAME.IDFW -> (binary_path, csv_path) for every paired file."""
exports, binaries = {}, {}
for dirpath, _dirs, files in os.walk(root):
for name in files:
up = name.upper()
full = os.path.join(dirpath, name)
if up.endswith(".IDFW.CSV") or up.endswith(".IDFH.CSV"):
exports.setdefault(name[:-4].upper(), full)
elif up.endswith(".IDFW") or up.endswith(".IDFH"):
binaries.setdefault(up, full)
return {k: (binaries[k], exports[k]) for k in binaries.keys() & exports.keys()}
def hdr_float(hdr, key):
raw = hdr.get(key)
if not raw:
return None
try:
return float(raw.split()[0])
except (ValueError, IndexError):
return None
def verify_waveform(binpath, csvpath, lsb):
"""Compare one IDFW against its export. Returns a result dict."""
out = {"file": os.path.basename(binpath), "status": "ok"}
try:
res = M.read_idf_file(binpath)
except NotImplementedError:
out["status"] = "not-thor"
return out
except Exception as exc: # noqa: BLE001 - harness reports, never raises
out["status"] = "decode-error"
out["detail"] = f"{type(exc).__name__}: {exc}"
return out
hdr, rows = parse_export(csvpath)
if not rows:
out["status"] = "no-gt-samples"
return out
gt = {ch: [r[i] for r in rows] for i, ch in enumerate(GEO)}
out["gt_len"] = len(rows)
out["geo_range"] = hdr.get("GeoRange")
exact = total = 0
lens, chan_status = {}, {}
ppv_err = {}
for ch in GEO:
arr = res.samples.get(ch, [])
ref = gt[ch]
lens[ch] = len(arr)
if len(arr) != len(ref):
chan_status[ch] = "length"
continue
if not arr:
chan_status[ch] = "empty"
continue
hits = sum(1 for c, v in zip(arr, ref) if abs(c * lsb - v) < 5e-5)
exact += hits
total += len(arr)
chan_status[ch] = "exact" if hits == len(arr) else "value"
gp = hdr_float(hdr, f"{ch}PPV")
if gp:
ppv_err[ch] = (max(abs(c) for c in arr) * lsb - gp) / gp
out["lens"] = lens
out["chan_status"] = chan_status
out["exact"] = exact
out["total"] = total
out["ppv_err"] = ppv_err
if all(v == "exact" for v in chan_status.values()):
out["status"] = "exact"
elif any(v == "length" for v in chan_status.values()):
out["status"] = "length-mismatch"
else:
out["status"] = "value-mismatch"
return out
def verify_histogram(binpath, csvpath, lsb):
out = {"file": os.path.basename(binpath), "status": "ok"}
try:
res = M.read_idf_file(binpath)
except NotImplementedError:
out["status"] = "not-thor"
return out
except Exception as exc: # noqa: BLE001
out["status"] = "decode-error"
out["detail"] = f"{type(exc).__name__}: {exc}"
return out
hdr, _rows = parse_export(csvpath)
out["n_intervals"] = len(res.intervals or [])
errs = {}
for ch, attr in (("Tran", "transverse_ips"), ("Vert", "vertical_ips"),
("Long", "longitudinal_ips")):
gp = hdr_float(hdr, f"{ch}PPV")
dv = getattr(res.event.peaks, attr, None)
if gp and dv:
errs[ch] = (dv - gp) / gp
out["ppv_err"] = errs
out["status"] = "peaks" if errs else "no-gt-peaks"
return out
def main():
ap = argparse.ArgumentParser()
ap.add_argument("--root", default=DEFAULT_ROOT)
ap.add_argument("--lsb", type=float, default=M._GEO_LSB_IPS)
ap.add_argument("--limit", type=int, default=0)
ap.add_argument("--kind", choices=("idfw", "idfh", "both"), default="both")
ap.add_argument("--show", type=int, default=15, help="worst-N detail rows")
args = ap.parse_args()
pairs = index_corpus(args.root)
keys = sorted(pairs)
if args.kind != "both":
keys = [k for k in keys if k.endswith(args.kind.upper())]
if args.limit:
keys = keys[: args.limit]
print(f"root: {args.root}")
print(f"geo LSB under test: {args.lsb!r} in/s per count")
print(f"paired files: {len(keys)}\n")
wf, hg = [], []
for k in keys:
binpath, csvpath = pairs[k]
if k.endswith(".IDFW"):
wf.append(verify_waveform(binpath, csvpath, args.lsb))
else:
hg.append(verify_histogram(binpath, csvpath, args.lsb))
if wf:
st = Counter(r["status"] for r in wf)
ex = sum(r.get("exact", 0) for r in wf)
tot = sum(r.get("total", 0) for r in wf)
print("=" * 68)
print(f"WAVEFORM (IDFW): {len(wf)} files")
for s, n in st.most_common():
print(f" {s:16} {n:5d} ({100*n/len(wf):5.1f}%)")
if tot:
print(f" per-sample exact: {ex}/{tot} = {100*ex/tot:.3f}%")
errs = [e for r in wf for e in r.get("ppv_err", {}).values()]
if errs:
print(f" PPV rel-error: median {statistics.median(errs):+.4%} "
f"mean {statistics.mean(errs):+.4%} "
f"max|.| {max(abs(e) for e in errs):.4%}")
bad = [r for r in wf if r["status"] not in ("exact",)]
if bad:
print(f"\n worst {min(args.show, len(bad))} of {len(bad)} non-exact:")
for r in bad[: args.show]:
print(f" {r['file']:42} {r['status']:16} "
f"lens={r.get('lens')} gt={r.get('gt_len')} "
f"{r.get('detail','')}")
if hg:
st = Counter(r["status"] for r in hg)
print("=" * 68)
print(f"HISTOGRAM (IDFH): {len(hg)} files")
for s, n in st.most_common():
print(f" {s:16} {n:5d} ({100*n/len(hg):5.1f}%)")
errs = [e for r in hg for e in r.get("ppv_err", {}).values()]
if errs:
print(f" PPV rel-error: median {statistics.median(errs):+.4%} "
f"mean {statistics.mean(errs):+.4%} "
f"max|.| {max(abs(e) for e in errs):.4%}")
within = lambda t: 100*sum(1 for e in errs if abs(e) <= t)/len(errs)
print(f" within 0.5%: {within(0.005):.1f}% "
f"within 2%: {within(0.02):.1f}% within 5%: {within(0.05):.1f}%")
return 0
if __name__ == "__main__":
raise SystemExit(main())
-5
View File
@@ -305,11 +305,6 @@ def main(argv=None) -> int:
default=0,
)
ev.total_samples = ev.total_samples or n_samp
# Sensor self-check traces from the IDFW fixed
# header, so regenerated .h5 files gain the v2
# /sensor_check group (mirrors save_imported_idf).
from micromate.sensor_check import decode_idf_sensor_check
ev.sensor_check = decode_idf_sensor_check(binary_bytes) or None
event_hdf5.write_event_hdf5(
hdf5_path, ev,
-93
View File
@@ -54,7 +54,6 @@ from s3_analyzer import ( # noqa: E402
write_claude_export,
)
from frame_db import FrameDB # noqa: E402
from minimateplus.binary_annotate import annotate_blastware_binary # noqa: E402
# ── colour palette ────────────────────────────────────────────────────────────
BG = "#1e1e1e"
@@ -2676,95 +2675,6 @@ class DownloadPanel(tk.Frame):
self._on_capture_ready(bw_path, s3_path, label)
# ─────────────────────────────────────────────────────────────────────────────
# Inspector panel — annotated hex view of a Series-3 binary
# ─────────────────────────────────────────────────────────────────────────────
class InspectorPanel(tk.Frame):
"""Load any Series-3 waveform binary and read it as an annotated hex dump.
Regions the decoder understands (header, STRT, per-channel sample records,
footer) are labelled and colour-coded; everything the decoder cannot account
for is flagged UNKNOWN, so undecoded bytes stand out for hand-inspection.
"""
_KIND_COLOR = {
"header": ACCENT,
"strt": YELLOW,
"sample": COL_S3,
"footer": FG_DIM,
"unknown": RED,
}
def __init__(self, parent: tk.Widget, initialdir=None, **kw) -> None:
super().__init__(parent, bg=BG, **kw)
self._path = None
self._initialdir = initialdir
self._build()
def _build(self) -> None:
bar = tk.Frame(self, bg=BG2)
bar.pack(side=tk.TOP, fill=tk.X)
tk.Button(bar, text="Open binary…", command=self._open, bg=BG3, fg=FG,
relief=tk.FLAT, font=MONO, activebackground=ACCENT).pack(side=tk.LEFT, padx=6, pady=6)
self._path_var = tk.StringVar(value="(no file loaded)")
tk.Label(bar, textvariable=self._path_var, bg=BG2, fg=FG_DIM, font=MONO).pack(side=tk.LEFT, padx=6)
self._summary_var = tk.StringVar(value="")
tk.Label(bar, textvariable=self._summary_var, bg=BG2, fg=FG, font=MONO).pack(side=tk.RIGHT, padx=10)
legend = tk.Frame(self, bg=BG2)
legend.pack(side=tk.TOP, fill=tk.X)
tk.Label(legend, text="legend:", bg=BG2, fg=FG_DIM, font=MONO).pack(side=tk.LEFT, padx=(8, 2))
for kind, color in self._KIND_COLOR.items():
tk.Label(legend, text=f"■ {kind}", bg=BG2, fg=color, font=MONO).pack(side=tk.LEFT, padx=5, pady=2)
self._text = scrolledtext.ScrolledText(
self, bg=BG, fg=FG, insertbackground=FG, font=MONO, wrap=tk.NONE, borderwidth=0)
self._text.pack(side=tk.TOP, fill=tk.BOTH, expand=True)
for kind, color in self._KIND_COLOR.items():
self._text.tag_configure(kind, foreground=color)
self._text.tag_configure("label", foreground="#ffffff", font=("Consolas", 9, "bold"))
self._text.tag_configure("dim", foreground=FG_DIM)
self._text.configure(state=tk.DISABLED)
def _open(self) -> None:
p = filedialog.askopenfilename(title="Open a Series-3 binary", initialdir=self._initialdir)
if p:
self.load(Path(p))
def load(self, path: Path) -> None:
try:
raw = path.read_bytes()
spans = annotate_blastware_binary(raw)
except Exception as e: # noqa: BLE001 — surface any read/annotate failure to the user
messagebox.showerror("Inspector", f"Failed to read/annotate:\n{path}\n\n{e}")
return
self._path = path
self._path_var.set(str(path))
self._render(raw, spans)
def _render(self, raw: bytes, spans) -> None:
t = self._text
t.configure(state=tk.NORMAL)
t.delete("1.0", tk.END)
unknown = sum(s.end - s.start for s in spans if s.kind == "unknown")
pct = 100 * unknown / max(1, len(raw))
self._summary_var.set(f"{len(raw)} B · {len(spans)} regions · {pct:.1f}% unknown")
for s in spans:
t.insert(tk.END, f"\n── {s.label} [0x{s.start:04x}:0x{s.end:04x}] {s.end - s.start} B ──\n", ("label",))
self._insert_hex(t, raw, s.start, s.end, s.kind)
t.configure(state=tk.DISABLED)
def _insert_hex(self, t: tk.Text, raw: bytes, start: int, end: int, kind: str) -> None:
for off in range(start, end, 16):
row = raw[off:min(off + 16, end)]
hx = " ".join(f"{b:02x}" for b in row).ljust(16 * 3 - 1)
txt = "".join(chr(b) if 32 <= b < 127 else "." for b in row)
t.insert(tk.END, f" 0x{off:04x} ", ("dim",))
t.insert(tk.END, hx, (kind,))
t.insert(tk.END, f" {txt}\n", ("dim",))
# ─────────────────────────────────────────────────────────────────────────────
# Main application window
# ─────────────────────────────────────────────────────────────────────────────
@@ -2820,9 +2730,6 @@ class SeismoLab(tk.Tk):
)
nb.add(self._download_panel, text=" Download ")
self._inspector_panel = InspectorPanel(nb)
nb.add(self._inspector_panel, text=" Inspector ")
self._nb = nb
self.protocol("WM_DELETE_WINDOW", self._on_close)
-133
View File
@@ -1,133 +0,0 @@
"""USBM RI8507 / OSMRE blasting compliance chart.
Renders the velocity-vs-frequency compliance scatter Blastware draws on its Event
Report: each channel's significant waveform cycles as ``(frequency, peak
velocity)`` points on log-log axes against the regulatory limit curve(s). A point
below the curve passes; above fails.
Two pieces, kept separate so both can be reused/extended:
* ``limit_at`` / ``limit_curve`` — the regulatory limit curve(s), as data.
* ``channel_compliance_points`` — the per-cycle (freq, velocity) scatter, by
the zero-crossing method (matches Blastware: each channel's cloud tops out
at that channel's PPV).
Limit curves (USBM RI8507 Figure B-1 / OSM 30 CFR 816.67), drawn CONTINUOUS — a
constant-displacement bound (sloped, ``v = 2πf·d``) meets a constant-velocity
plateau at the frequency where they're equal, so there are no vertical steps
(matching how Blastware draws it). Two lines:
* **Drywall** (modern gypsum board) — 0.75 in/s plateau (solid).
* **Plaster** on wood lath (older homes) — 0.50 in/s plateau (dashed).
Both use a 0.030 in low-frequency displacement bound and rise through a 0.010 in
displacement bound to a 2.0 in/s high-frequency plateau. Values from USBM RI8507
(Appendix B) / 30 CFR 816.67; ⚠ confirm the exact shape against a Blastware
report before trusting for compliance.
"""
from __future__ import annotations
import math
from typing import Dict, Sequence, Tuple
import numpy as np
from matplotlib.ticker import FixedLocator, NullLocator
# curve name → (low-freq "ultimate" displacement in, mid velocity plateau in/s,
# high-freq displacement in, high-freq velocity plateau in/s).
# RI8507 Fig B-1 (p.74): ultimate max displacement 0.030 in (< ~4 Hz), plateau
# 0.75 (Drywall) / 0.50 (plaster), rising diagonal at 0.008 in displacement up to
# a 2.0 in/s plateau reached at ~40 Hz.
_CURVES: Dict[str, Tuple[float, float, float, float]] = {
"Drywall": (0.030, 0.75, 0.008, 2.00),
"Plaster": (0.030, 0.50, 0.008, 2.00),
}
# how each curve is stroked on the chart
_CURVE_STYLE = {"Drywall": {"ls": "-", "lw": 1.0}, "Plaster": {"ls": "--", "lw": 0.9}}
STANDARDS = tuple(_CURVES)
# Blastware's channel markers/colours on the compliance chart.
_CHANNEL_STYLE = {
"Tran": ("+", "#d62728"), # red +
"Vert": ("x", "#2ca02c"), # green x
"Long": ("o", "#1f77b4"), # blue o
}
def limit_at(freq_hz: float, curve: str = "Drywall") -> float:
"""Max allowed PPV (in/s) at ``freq_hz`` for ``curve`` (continuous)."""
d_low, v_mid, d_high, v_high = _CURVES[curve]
f = max(freq_hz, 1.0)
f_a = v_mid / (2.0 * math.pi * d_low) # disp_low → vel_mid
f_b = v_mid / (2.0 * math.pi * d_high) # vel_mid → disp_high
f_c = v_high / (2.0 * math.pi * d_high) # disp_high → vel_high
if f <= f_a:
return 2.0 * math.pi * f * d_low
if f <= f_b:
return v_mid
if f <= f_c:
return 2.0 * math.pi * f * d_high
return v_high
def limit_curve(curve: str = "Drywall", fmin: float = 1.0, fmax: float = 100.0, n: int = 400):
"""(freqs, limits) sampled across the band for plotting one curve."""
freqs = np.logspace(np.log10(fmin), np.log10(fmax), n)
return freqs, np.array([limit_at(f, curve) for f in freqs])
def channel_compliance_points(
samples: Sequence[float], sps: float, fmin: float = 1.0, fmax: float = 100.0,
vmin: float = 0.0,
) -> Tuple[np.ndarray, np.ndarray]:
"""Per-cycle (frequency, peak velocity) scatter for one channel.
Zero-crossing method: split the trace at sign changes; each half-cycle
contributes one point at ``(1/(2·half_period), max|amplitude|)``. Matches
Blastware — the cloud's ceiling is the channel PPV. ``samples`` must be in the
velocity unit you want plotted (in/s). Points outside ``[fmin, fmax]`` or at
or below ``vmin`` are dropped.
"""
x = np.asarray(samples, dtype=float)
if x.size < 3:
return np.empty(0), np.empty(0)
zc = np.where(np.diff(np.signbit(x)))[0]
freqs, vels = [], []
for a, b in zip(zc[:-1], zc[1:]):
half_period = (b - a) / sps
if half_period <= 0:
continue
freqs.append(1.0 / (2.0 * half_period))
vels.append(float(np.abs(x[a:b + 1]).max()))
f = np.array(freqs)
v = np.array(vels)
keep = (f >= fmin) & (f <= fmax) & (v > vmin)
return f[keep], v[keep]
def draw_compliance_chart(ax, channels: Dict[str, Sequence[float]], sps: float) -> None:
"""Draw the compliance chart (both limit curves + per-channel scatter)."""
for name, style in _CURVE_STYLE.items():
cf, cv = limit_curve(name)
ax.plot(cf, cv, color="#333", zorder=3, **style)
for ch, (marker, color) in _CHANNEL_STYLE.items():
samples = channels.get(ch)
if samples is None or len(samples) == 0:
continue
f, v = channel_compliance_points(samples, sps)
ax.scatter(f, v, marker=marker, s=12, c=color, linewidths=0.7, zorder=4, label=ch)
ax.set_xscale("log")
ax.set_yscale("log")
ax.set_xlim(1, 100)
ax.set_ylim(0.0394, 10)
ax.set_box_aspect(1) # square plot box (log-log compliance charts are square)
xt = [1, 2, 5, 10, 20, 50, 100]
yt = [0.0394, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10]
ax.xaxis.set_major_locator(FixedLocator(xt)); ax.xaxis.set_minor_locator(NullLocator())
ax.yaxis.set_major_locator(FixedLocator(yt)); ax.yaxis.set_minor_locator(NullLocator())
ax.set_xticklabels([str(v) for v in xt])
ax.set_yticklabels([("%g" % v) for v in yt])
ax.set_xlabel("Frequency (Hz)", fontsize=7)
ax.set_ylabel("Velocity (in/s)", fontsize=7)
ax.tick_params(labelsize=6)
ax.grid(True, which="both", ls=":", lw=0.4, color="#ccc")
-13
View File
@@ -1,13 +0,0 @@
"""One door for every device request -- see the 2026-10-20 parity spec."""
from .errors import (
BadRequest, CallHomeInProgress, ConnectFailed, DeviceError, EventNotFound,
MalformedReply, NoAnswer, NotSupported, StaleEvent, UnitBusy, WrongUnit,
translate,
)
from .models import (
DownloadedEvent, EventDownload, EventList, EventRef, UnitAddress, UnitInfo,
UnitSettings, UnitStatus,
)
from .series import normalise_serial, series_for_serial
from .locks import UnitLocks
from .access import DeviceAccess
-194
View File
@@ -1,194 +0,0 @@
"""DeviceAccess -- the one door every device request passes through.
The control surface does not care which series it is talking to; this does.
"""
from __future__ import annotations
import logging
import threading
import time
from typing import Any, Callable, Dict, Optional
from .errors import ConnectFailed, DeviceError, NoAnswer, WrongUnit
from .events import parse_event_id
from .locks import UnitLocks
from .models import DownloadedEvent, EventList, UnitAddress, UnitInfo, UnitSettings, UnitStatus
from .s3 import Series3Adapter, default_s3_client_factory
from .s4 import (
Series4Session, default_s4_client_factory, s4_download_event, s4_identify, s4_list_events,
s4_settings, s4_status,
)
from .series import normalise_serial, series_for_serial
log = logging.getLogger("sfm.device_access")
class DeviceAccess:
def __init__(
self, *,
s3_client_factory: Callable[[UnitAddress], Any] = default_s3_client_factory,
s4_client_factory: Callable[[UnitAddress], Any] = default_s4_client_factory,
clock: Callable[[], float] = time.monotonic,
lock_timeout: float = 20.0,
keepalive_s: float = 60.0,
idle_hangup_s: float = 300.0,
reaper_interval_s: float = 5.0,
start_reaper: bool = True,
) -> None:
self._locks = UnitLocks(lock_timeout)
self._s3 = Series3Adapter(s3_client_factory)
self._s4_factory = s4_client_factory
self._clock = clock
self._keepalive_s = keepalive_s
self._idle_hangup_s = idle_hangup_s
self._reaper_interval_s = reaper_interval_s
self._start_reaper = start_reaper
self._reaper: Optional[threading.Thread] = None
self._sessions: Dict[str, Series4Session] = {}
self._sessions_guard = threading.Lock()
# ── public operations ─────────────────────────────────────────────────────
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
return self._dispatch(address, serial, self._s3.identify, s4_identify)
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
return self._dispatch(address, serial, self._s3.status, s4_status)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
return self._dispatch(address, serial, self._s3.settings, s4_settings)
def list_events(self, address: UnitAddress, serial: str) -> EventList:
return self._dispatch(address, serial, self._s3.list_events, s4_list_events)
def download_event(self, address: UnitAddress, serial: str, event_id: str) -> DownloadedEvent:
"""Read-only on the unit. Holds the unit for the whole download, so
other requests for it wait, then get 423."""
key, stamp = parse_event_id(event_id, serial) # BadRequest before any I/O
return self._dispatch(
address, serial,
lambda a, s: self._s3.download_event(a, s, key, stamp),
lambda c, s: s4_download_event(c, s, key, stamp))
def held_serial(self, address: UnitAddress) -> Optional[str]:
"""Serial of the OPEN held Series-4 line at this address, else None. No I/O."""
with self._sessions_guard:
session = self._sessions.get(address.key)
if session is not None and session.is_open:
return session.serial
return None
def hang_up(self, address: UnitAddress) -> bool:
with self._locks.hold(address.key):
with self._sessions_guard:
session = self._sessions.pop(address.key, None)
if session is None:
return False
was_open = session.is_open
session.hang_up()
return was_open
# ── dispatch ──────────────────────────────────────────────────────────────
def _dispatch(self, address: UnitAddress, serial: str,
s3_op: Callable[[UnitAddress, str], Any],
s4_op: Callable[[Any, str], Any]) -> Any:
serial = normalise_serial(serial)
series = series_for_serial(serial) # raises BadRequest before any I/O
with self._locks.hold(address.key):
if series == 3:
with self._sessions_guard:
held = self._sessions.get(address.key)
if held is not None and held.is_open:
raise WrongUnit(
f"a Series-4 line to {held.serial} is held at {address.key}; "
"a Series-3 unit cannot be there -- POST /device/hangup first "
"if the modem has moved")
return s3_op(address, serial)
session = self._session_for(address, serial)
was_held = session.is_open
try:
return session.run(lambda client: s4_op(client, serial))
except DeviceError as exc:
self._forget_if_closed(address, session)
# A held line the peer dropped still reads open (the transport only
# learns at EOF), so the first request on it times out or fails.
# Call up fresh and retry ONCE. Safe only because every operation
# here is a read (identify, status, settings, list, download -- all
# idempotent); writes (phase 3) must NOT
# inherit this -- a write whose ack was lost must never be sent twice.
if was_held and isinstance(exc, (NoAnswer, ConnectFailed)):
self._drop(address.key, session)
session.hang_up()
session = self._session_for(address, serial)
try:
return session.run(lambda client: s4_op(client, serial))
except DeviceError:
self._forget_if_closed(address, session)
raise
raise
def _forget_if_closed(self, address: UnitAddress, session: Series4Session) -> None:
if not session.is_open:
self._drop(address.key, session)
def _session_for(self, address: UnitAddress, serial: str) -> Series4Session:
with self._sessions_guard:
session = self._sessions.get(address.key)
if session is not None and session.serial != serial:
if session.is_open:
raise WrongUnit(
f"a Series-4 line to {session.serial} is held at {address.key}; "
f"{serial} cannot be reached there -- POST /device/hangup first "
"if the modem has moved")
session = None
if session is None:
session = Series4Session(address, serial, self._s4_factory, clock=self._clock)
self._sessions[address.key] = session
self._ensure_reaper()
return session
# ── the reaper ────────────────────────────────────────────────────────────
def tick(self, now: Optional[float] = None) -> None:
"""Per held line: hang up if idle, else keep alive, else listen for a ring."""
now = self._clock() if now is None else now
with self._sessions_guard:
items = list(self._sessions.items())
for key, session in items:
with self._locks.try_hold(key) as held:
if not held:
continue # mid-request: not idle
if not session.is_open:
self._drop(key, session)
continue
try:
if now - session.last_used >= self._idle_hangup_s:
session.hang_up()
self._drop(key, session)
elif now - session.last_traffic >= self._keepalive_s:
session.keepalive()
else:
session.listen()
except DeviceError as exc:
log.warning("held line %s closed: %s", key, exc)
self._drop(key, session)
def _drop(self, key: str, session: Series4Session) -> None:
with self._sessions_guard:
if self._sessions.get(key) is session:
del self._sessions[key]
def _ensure_reaper(self) -> None:
if not self._start_reaper or self._reaper is not None:
return
self._reaper = threading.Thread(target=self._reaper_loop, name="sfm-held-lines", daemon=True)
self._reaper.start()
def _reaper_loop(self) -> None:
while True:
time.sleep(self._reaper_interval_s)
try:
self.tick()
except Exception: # noqa: BLE001
log.exception("held-line reaper tick failed")
-73
View File
@@ -1,73 +0,0 @@
"""Typed device errors, each with the HTTP status the endpoints return."""
from __future__ import annotations
import micromate.protocol as _mm_proto
import minimateplus.protocol as _mmp_proto
class DeviceError(Exception):
http_status = 500
class BadRequest(DeviceError):
http_status = 422
class NotSupported(DeviceError):
http_status = 501
class WrongUnit(DeviceError):
http_status = 409
class UnitBusy(DeviceError):
http_status = 423
class ConnectFailed(DeviceError):
http_status = 503
class CallHomeInProgress(DeviceError):
http_status = 503
class NoAnswer(DeviceError):
http_status = 504
class MalformedReply(DeviceError):
http_status = 502
class EventNotFound(DeviceError):
http_status = 404
class StaleEvent(DeviceError):
"""The event at that key is not the one listed -- the unit was erased, or
its memory wrapped, since the list was read."""
http_status = 409
_TIMEOUTS = (_mm_proto.TimeoutError, _mmp_proto.TimeoutError)
_PROTOCOL = (_mm_proto.ProtocolError, _mmp_proto.ProtocolError)
def translate(exc: BaseException, *, connecting: bool) -> DeviceError:
"""Map a library exception to a typed error.
Order matters: each library's TimeoutError is a ProtocolError subclass, and
the builtin TimeoutError (a failed TCP connect) is an OSError.
"""
if isinstance(exc, DeviceError):
return exc
if isinstance(exc, _TIMEOUTS):
return NoAnswer(f"the unit did not answer: {exc}")
if isinstance(exc, _PROTOCOL):
return MalformedReply(f"bad reply from the unit: {exc}")
if isinstance(exc, OSError):
what = "could not connect" if connecting else "connection lost"
return ConnectFailed(f"{what}: {exc}")
return DeviceError(f"device error: {exc}")
-51
View File
@@ -1,51 +0,0 @@
"""Event identity. An `event_id` is `<serial>:<key hex>:<YYYYmmddHHMMSS>`.
The key alone is not enough: both series reuse keys (a MiniMate restarts at
01110000 after an erase; every Micromate's counter starts at the same value).
The timestamp turns a stale id into a loud StaleEvent instead of a download of
whatever now sits at that key. "-" stands in for an unknown timestamp.
"""
from __future__ import annotations
import datetime
from typing import Optional, Tuple
from .errors import BadRequest
from .series import normalise_serial
_NO_STAMP = "-"
_STAMP_FMT = "%Y%m%d%H%M%S"
def stamp_of(dt: Optional[datetime.datetime]) -> Optional[str]:
return dt.strftime(_STAMP_FMT) if dt is not None else None
def iso_of(dt: Optional[datetime.datetime]) -> Optional[str]:
return dt.isoformat() if dt is not None else None
def make_event_id(serial: str, key: bytes, stamp: Optional[str]) -> str:
return f"{normalise_serial(serial)}:{key.hex()}:{stamp or _NO_STAMP}"
def parse_event_id(event_id: str, serial: str) -> Tuple[bytes, Optional[str]]:
"""(key, stamp) for an id that belongs to `serial`; BadRequest otherwise."""
parts = (event_id or "").strip().split(":")
if len(parts) != 3:
raise BadRequest(f"not an event_id: {event_id!r} -- take it from GET /device/events")
id_serial, key_hex, stamp = parts
if normalise_serial(id_serial) != normalise_serial(serial):
raise BadRequest(f"event_id {event_id!r} belongs to {id_serial}, not {serial}")
try:
key = bytes.fromhex(key_hex)
except ValueError:
key = b""
if len(key) != 4:
raise BadRequest(f"event_id {event_id!r}: the key must be 8 hex digits")
if stamp != _NO_STAMP:
try:
datetime.datetime.strptime(stamp, _STAMP_FMT)
except ValueError:
raise BadRequest(f"event_id {event_id!r}: bad timestamp {stamp!r}") from None
return key, (None if stamp == _NO_STAMP else stamp)
-41
View File
@@ -1,41 +0,0 @@
"""One connection per unit. A modem allows a single TCP session, so two
requests must take turns instead of opening a second connection."""
from __future__ import annotations
import threading
from contextlib import contextmanager
from typing import Dict, Iterator, Optional
from .errors import UnitBusy
class UnitLocks:
def __init__(self, timeout: float = 20.0) -> None:
self._timeout = timeout
self._guard = threading.Lock()
self._locks: Dict[str, threading.Lock] = {}
def _lock_for(self, key: str) -> threading.Lock:
with self._guard:
return self._locks.setdefault(key, threading.Lock())
@contextmanager
def hold(self, key: str, timeout: Optional[float] = None) -> Iterator[None]:
lock = self._lock_for(key)
wait = self._timeout if timeout is None else timeout
if not lock.acquire(timeout=wait):
raise UnitBusy(f"the unit at {key} is busy with another request; try again shortly")
try:
yield
finally:
lock.release()
@contextmanager
def try_hold(self, key: str) -> Iterator[bool]:
lock = self._lock_for(key)
got = lock.acquire(blocking=False)
try:
yield got
finally:
if got:
lock.release()
-134
View File
@@ -1,134 +0,0 @@
"""Series-neutral models. Every operation returns the same shape for both
series; anything only one series has goes under `detail`."""
from __future__ import annotations
import datetime
from dataclasses import dataclass, field
from typing import Any, Dict, List, Optional
from .errors import BadRequest
@dataclass(frozen=True)
class UnitAddress:
host: Optional[str]
tcp_port: Optional[int]
port: Optional[str]
baud: Optional[int]
def __post_init__(self) -> None:
if not self.host and not self.port:
raise BadRequest(
"specify 'host' (TCP, e.g. ?host=10.0.0.5&tcp_port=9034) "
"or 'port' (serial, e.g. ?port=/dev/ttyACM0)"
)
@property
def key(self) -> str:
"""One key per physical link -- what the per-unit lock is keyed on."""
if self.host:
return f"tcp:{self.host}:{self.tcp_port}"
return f"serial:{self.port}"
@dataclass
class UnitInfo:
serial: str
series: int
model: Optional[str]
firmware: Optional[str]
monitoring: Optional[bool]
active_setup: Optional[str]
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class UnitStatus:
serial: str
series: int
monitoring: bool
battery_volts: Optional[float]
memory_total_bytes: Optional[int]
memory_free_bytes: Optional[int]
device_time: Optional[str] # ISO, the unit's own local time
event_count: Optional[int] # None where it is not cheap (Series 3)
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class UnitSettings:
serial: str
series: int
setup_name: Optional[str]
record_mode: Optional[str] # the unit's own name for its mode
sample_rate: Optional[int]
record_time_s: Optional[float]
histogram_interval_s: Optional[int]
geo_trigger_ips: Optional[float]
notes: Dict[str, str] = field(default_factory=dict)
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class EventRef:
"""One stored event, as listed. `event_id` is opaque: pass it back to
download the event. `index` is its position in the list right now; an
erase renumbers it, so it is for display, never identity."""
event_id: str
serial: str
series: int
index: int
timestamp: Optional[str] # ISO, the unit's own local time
record_type: Optional[str] # "waveform" | "histogram"
peak_vector_sum_ips: Optional[float]
peaks_ips: Dict[str, float] # geophones only: tran / vert / long
filename: Optional[str] # the name the vendor's software gives it
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class EventList:
serial: str
series: int
events: List[EventRef]
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class EventDownload:
"""What a download stored. The file and waveform are then served at
/db/events/{db_event_id}/... ."""
event_id: str
serial: str
series: int
db_event_id: Optional[str]
stored_filename: str
filesize: Optional[int] # None only for a stored row with no file recorded
sha256: Optional[str] # None when the event was already stored
inserted: bool # False: already stored; nothing was written (detail.already_stored)
verified: Optional[bool] # True: decode self-check passed; None: no check exists
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class DownloadedEvent:
"""The device side's result, before SFM stores it. Not an HTTP shape: it
carries the payload -- a Series-3 Event + its 5A frames + the compliance
config, or a Series-4 file's bytes -- to sfm.event_ingest.
`timestamp` is the event's time as the unit reported it: the store looks up
an existing row by (serial, timestamp) before writing anything. `record` is
what the unit's own event record said (Series 4's 0x0C), for the fields the
file alone does not give."""
event_id: str
serial: str
series: int
filename: str
verified: Optional[bool]
idf_bytes: Optional[bytes] = field(default=None, repr=False)
event: Any = field(default=None, repr=False)
a5_frames: Optional[list] = field(default=None, repr=False)
compliance: Any = field(default=None, repr=False)
timestamp: Optional[datetime.datetime] = None
record: Dict[str, Any] = field(default_factory=dict)
detail: Dict[str, Any] = field(default_factory=dict)
-228
View File
@@ -1,228 +0,0 @@
"""Series-3 adapter. Connect-per-request, as SFM has always done for
MiniMates -- a held session waits for the bench test in the spec."""
from __future__ import annotations
import datetime
import logging
import struct
from typing import Any, Callable, Optional
from minimateplus import MiniMateClient
from minimateplus.blastware_file import blastware_filename
from minimateplus.transport import TcpTransport
from .errors import DeviceError, EventNotFound, MalformedReply, NoAnswer, StaleEvent, WrongUnit, translate
from .events import iso_of, make_event_id, stamp_of
from .models import DownloadedEvent, EventList, EventRef, UnitAddress, UnitInfo, UnitSettings, UnitStatus
log = logging.getLogger("sfm.device_access")
S3_DEFAULT_BAUD = 38400
S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"}
S3_EVENT_TIMEOUT = 120.0 # what the legacy event-download routes use
def default_s3_client_factory(address: UnitAddress, timeout: Optional[float] = None) -> MiniMateClient:
if address.host:
return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port),
timeout=10.0 if timeout is None else timeout)
if timeout is None:
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD)
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD, timeout=timeout)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
def _s3_dt(ev: Any) -> Optional[datetime.datetime]:
ts = getattr(ev, "timestamp", None)
if ts is None or ts.hour is None:
return None
try:
return datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
except (TypeError, ValueError):
return None
def _s3_filename(ev: Any, serial: str) -> Optional[str]:
try:
return blastware_filename(ev, serial)
except Exception: # noqa: BLE001
return None
S3_RECORD_TYPE_NOTE = "Series 3's event record does not say waveform or histogram; not decoded yet"
def _s3_ref(ev: Any, serial: str) -> EventRef:
"""record_type is always None: minimateplus's 0C decode reports "Waveform"
for every record layout, histograms included, so it cannot be trusted
here. Null rather than wrong until a histogram's 0C is captured."""
dt = _s3_dt(ev)
pv = ev.peak_values
peaks = {}
if pv is not None:
peaks = {k: v for k, v in (("tran", pv.tran), ("vert", pv.vert), ("long", pv.long))
if v is not None}
return EventRef(
event_id=make_event_id(serial, ev._waveform_key, stamp_of(dt)),
serial=serial, series=3, index=ev.index, timestamp=iso_of(dt),
record_type=None,
peak_vector_sum_ips=pv.peak_vector_sum if pv is not None else None,
peaks_ips=peaks, filename=_s3_filename(ev, serial),
detail={"mic_psi": pv.micl if pv is not None else None,
"record_type_note": S3_RECORD_TYPE_NOTE},
)
class Series3Adapter:
def __init__(self, client_factory: Callable[..., Any] = default_s3_client_factory) -> None:
self._factory = client_factory
def _run(self, address: UnitAddress, fn: Callable[[Any], Any], timeout: Optional[float] = None) -> Any:
def attempt() -> Any:
client = self._factory(address) if timeout is None else self._factory(address, timeout=timeout)
try:
client.open()
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
try:
return fn(client)
except DeviceError:
raise
except Exception as exc:
raise translate(exc, connecting=False) from exc
finally:
_close(client)
try:
return attempt()
except NoAnswer:
# A MiniMate that has just had its serial lines asserted can take
# 5-10 s to boot, and shows it as silence; one retry covers it. TCP
# only -- on a serial cable a silence is a real fault. Narrower than
# server._run_with_retry (any protocol error): retrying a
# MalformedReply would also retry "no settings block", which a
# reconnect cannot fix.
if not address.host:
raise
log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key)
return attempt()
@staticmethod
def _check(serial_reported: str, serial: str, address: UnitAddress) -> None:
if (serial_reported or "").strip().upper() != serial:
raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}")
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
def op(client: Any) -> UnitInfo:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
return UnitInfo(
serial=info.serial, series=3, model=info.model, firmware=info.firmware_version,
monitoring=None, active_setup=cc.setup_name if cc else None,
detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version},
)
return self._run(address, op)
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
def op(client: Any) -> UnitStatus:
client.poll()
ms = client.get_monitor_status()
return UnitStatus(
serial=serial, series=3, monitoring=ms.is_monitoring,
battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None,
memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free,
device_time=None, event_count=None,
# Series 3 status reads no serial, so the serial shown is the one requested, not one the unit reported.
detail={"serial_verified": False},
)
return self._run(address, op)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
def op(client: Any) -> UnitSettings:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
if cc is None:
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
mode = None
if cc.recording_mode is not None:
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
notes = {
label: value for label, value in (
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
) if value is not None
}
return UnitSettings(
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
notes=notes,
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
"geo_range": cc.geo_range},
)
return self._run(address, op)
def list_events(self, address: UnitAddress, serial: str) -> EventList:
def op(client: Any) -> EventList:
info = client.connect()
self._check(info.serial, serial, address)
return EventList(serial=serial, series=3,
events=[_s3_ref(ev, serial) for ev in client.list_event_headers()])
# The default timeout: a header walk is small replies only, so a lost
# one costs 10 s (TCP) with the unit locked, not 120 s.
return self._run(address, op)
def download_event(self, address: UnitAddress, serial: str, key: bytes,
stamp: Optional[str]) -> DownloadedEvent:
# The walk compares this with the target's 0C and, on a mismatch, sends
# no 5A: a stale id costs a header walk, not a full download of the
# wrong event.
iso = datetime.datetime.strptime(stamp, "%Y%m%d%H%M%S").isoformat() if stamp is not None else None
def op(client: Any) -> DownloadedEvent:
info = client.connect()
self._check(info.serial, serial, address)
try:
ev = client.download_event_by_key(key, expected_timestamp=iso)
except struct.error as exc:
# Inferred, not measured here: the known 5A page bug. An event past the unit's
# first 64 KB drives TERM's offset negative, and struct.pack rejects it
# (seismo-relay CLAUDE.md, "KNOWN BUG").
raise MalformedReply(
f"event {key.hex()}: its download could not be assembled ({exc}) -- most "
"likely the known bug with events past the unit's first 64 KB; not saved"
) from exc
if ev is None:
raise EventNotFound(f"no event {key.hex()} on {serial} -- list the events again")
found = stamp_of(_s3_dt(ev))
if stamp is not None and found is None:
raise MalformedReply(
f"could not read event {key.hex()}'s record (0C) to confirm it is the one "
"listed -- not downloaded; try again")
if stamp is not None and found != stamp:
raise StaleEvent(
f"the event at {key.hex()} on {serial} is from {found}, not {stamp} -- "
"the unit was erased or wrapped since the list was read; list again")
if not ev._a5_frames:
raise MalformedReply(f"event {key.hex()}: no waveform data received (the 5A download failed)")
filename = _s3_filename(ev, serial)
if filename is None:
raise MalformedReply(f"event {key.hex()} has no usable timestamp, so it cannot be named or stored")
return DownloadedEvent(
event_id=make_event_id(serial, key, found), serial=serial, series=3,
filename=filename, verified=None, event=ev, a5_frames=ev._a5_frames,
compliance=info.compliance_config, timestamp=_s3_dt(ev),
detail={"a5_frames": len(ev._a5_frames)},
)
return self._run(address, op, timeout=S3_EVENT_TIMEOUT)
-304
View File
@@ -1,304 +0,0 @@
"""Series-4 sessions: call up once, stay on the line, hang up when idle.
⚠ Imports only minimateplus.transport from the Series-3 package. Nothing
here may build or send a Series-3 frame -- SESSION_RESET (41 03) has never
been sent to a Micromate.
"""
from __future__ import annotations
import logging
import time
from typing import Any, Callable, Optional, TypeVar
from micromate.client import MicromateClient
from micromate.protocol import THOR_CHUNK_SIZE
from minimateplus.transport import BaseTransport, SerialTransport, TcpTransport
from .errors import (
CallHomeInProgress, DeviceError, EventNotFound, MalformedReply, StaleEvent, WrongUnit, translate,
)
from .events import iso_of, make_event_id, stamp_of
from .models import DownloadedEvent, EventList, EventRef, UnitAddress, UnitInfo, UnitSettings, UnitStatus
from .series import normalise_serial
log = logging.getLogger("sfm.device_access")
T = TypeVar("T")
RING = b"RADIO RING"
S4_DEFAULT_BAUD = 115200
class RingDetected(Exception):
"""The unit sent RADIO RING: it is calling home up this connection."""
class RingWatchTransport(BaseTransport):
"""Passes bytes through; raises RingDetected the moment RADIO RING appears
OUTSIDE a frame, including when it is split across two reads.
Inside a frame the bytes are data: the 0x2C call-home config block's dial
string is literally "RADIO RING". A frame runs from STX to an unescaped
ETX; inside it DLE escapes the next byte.
"""
_STX, _ETX, _DLE = 0x02, 0x03, 0x10
def __init__(self, inner: BaseTransport) -> None:
self._inner = inner
self._tail = b""
self._in_frame = False
self._escaped = False
def connect(self) -> None:
self._inner.connect()
def disconnect(self) -> None:
self._inner.disconnect()
@property
def is_connected(self) -> bool:
return self._inner.is_connected
def write(self, data: bytes) -> None:
# A request starts a new exchange (MicromateProtocol resets its parser
# here too), so a stray STX on an idle line cannot hide the next ring.
self._in_frame = self._escaped = False
self._inner.write(data)
def read(self, n: int) -> bytes:
data = self._inner.read(n)
for b in data:
if self._in_frame:
if self._escaped:
self._escaped = False
elif b == self._DLE:
self._escaped = True
elif b == self._ETX:
self._in_frame = False
elif b == self._STX:
self._in_frame = True
self._tail = b""
else:
self._tail = (self._tail + bytes([b]))[-len(RING):]
if self._tail == RING:
self._tail = b""
raise RingDetected("RADIO RING")
return data
def default_s4_client_factory(address: UnitAddress, recv_timeout: float = 10.0) -> MicromateClient:
if address.host:
inner: BaseTransport = TcpTransport(address.host, port=address.tcp_port)
else:
inner = SerialTransport(address.port, address.baud or S4_DEFAULT_BAUD)
return MicromateClient(RingWatchTransport(inner), recv_timeout=recv_timeout)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
_RING_MESSAGE = ("the unit started calling home; SFM hung up so the call can "
"reach THOR -- try again in a few minutes")
class Series4Session:
"""One held line to one Micromate.
`last_used` is the last *user* request: the idle hang-up measures it.
`last_traffic` is any exchange, keep-alives included: the keep-alive
schedule measures it. If keep-alives counted as use, the line would never
go idle.
Invariant -- which errors keep the line. An operation raises a
`DeviceError` only for a verdict reached over a healthy link: the event is
not there, the id is stale, the record cannot be named. `_exchange` keeps
the line for those. Anything the library raises means the link is
suspect, and `_exchange` hangs up. `DecodeMismatch` is a library error,
so it hangs up too -- conservative, since the link may be fine. Operations
added in later phases must keep to this: never wrap a link failure in a
`DeviceError` inside an op, or the line stays open on a broken link.
"""
def __init__(self, address: UnitAddress, serial: str,
client_factory: Callable[[UnitAddress], Any],
clock: Callable[[], float] = time.monotonic) -> None:
self.address = address
self.serial = normalise_serial(serial)
self._factory = client_factory
self._clock = clock
self._client: Optional[Any] = None
self.info = None
self.last_used = clock()
self.last_traffic = self.last_used
@property
def is_open(self) -> bool:
client = self._client # one read: held_serial() calls this without the unit lock
return client is not None and client.is_open()
def call_up(self):
client = self._factory(self.address)
try:
client.open()
info = client.connect()
except RingDetected as exc:
_close(client)
log.warning("RADIO RING from %s during call-up -- released the line", self.address.key)
raise CallHomeInProgress(_RING_MESSAGE) from exc
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
if normalise_serial(info.serial) != self.serial:
_close(client)
raise WrongUnit(f"asked for {self.serial} but {info.serial} answered at {self.address.key}")
self._client, self.info = client, info
self.last_used = self.last_traffic = self._clock()
log.info("call-up: %s at %s, staying on the line", self.serial, self.address.key)
return info
def _exchange(self, op: Callable[[Any], T]) -> T:
try:
return op(self._client)
except RingDetected as exc:
self.hang_up()
log.warning("RADIO RING from %s -- released the line so the call reaches THOR",
self.address.key)
raise CallHomeInProgress(_RING_MESSAGE) from exc
except DeviceError:
# The operation's own verdict (event not found, stale id): the line
# is healthy, so keep it. Library errors still hang up below.
raise
except Exception as exc:
self.hang_up()
raise translate(exc, connecting=False) from exc
def run(self, op: Callable[[Any], T]) -> T:
"""A user request. Calls up first if the line is not open."""
if not self.is_open:
self.call_up()
result = self._exchange(op)
self.last_used = self.last_traffic = self._clock()
return result
def keepalive(self) -> None:
"""A POLL so the modem's idle timer does not drop the line. Not use."""
if not self.is_open:
return
self._exchange(lambda c: c.protocol.poll())
self.last_traffic = self._clock()
def listen(self) -> None:
"""Read anything the unit sent unprompted; send nothing. Not use."""
if not self.is_open:
return
self._exchange(lambda c: c.read_unsolicited())
def hang_up(self) -> None:
if self._client is not None:
_close(self._client)
self._client = None
log.info("hang-up: %s at %s", self.serial, self.address.key)
# ── Operations (each runs inside Series4Session.run) ──────────────────────────
def s4_identify(client: Any, serial: str) -> UnitInfo:
info = client.connect()
return UnitInfo(
serial=info.serial, series=4, model=info.model,
firmware=None, # the version string lives in 0x01, undecoded
monitoring=info.monitoring, active_setup=info.active_setup,
detail={"manufacturer": info.manufacturer, "firmware_line": info.firmware_line},
)
def s4_status(client: Any, serial: str) -> UnitStatus:
st = client.get_state()
count = client.get_event_count()
return UnitStatus(
serial=serial, series=4, monitoring=st.monitoring, battery_volts=st.battery_volts,
memory_total_bytes=st.memory_total_bytes, memory_free_bytes=st.memory_free_bytes,
device_time=st.device_time.isoformat() if st.device_time else None,
event_count=count,
)
def s4_settings(client: Any, serial: str) -> UnitSettings:
s = client.get_setup()
return UnitSettings(
serial=serial, series=4, setup_name=s.name, record_mode=s.record_mode_name,
sample_rate=s.sample_rate, record_time_s=s.record_time_s,
histogram_interval_s=s.histogram_interval_s,
geo_trigger_ips=s.geo_trigger_ips[0], # the keypad writes all three the same
notes=dict(s.notes),
detail={
"pretrigger_s": s.pretrigger_s,
"auto_record_stop": s.auto_record_stop,
"auto_stop_after_s": s.auto_stop_after_s,
"geophones_active": s.geophones_active,
"mic_active": s.mic_active,
"trigger_on_geophones": s.trigger_on_geophones,
"trigger_on_mic": s.trigger_on_mic,
"geo_trigger_ips_per_channel": list(s.geo_trigger_ips),
"mic_type": s.mic_type,
"mic_trigger_psi": s.mic_trigger_psi,
"mic_trigger_db": s.mic_trigger_db,
"job_number_enabled": s.job_number_enabled,
"job_number": s.job_number,
"scaled_distance_enabled": s.scaled_distance_enabled,
"distance_ft": s.distance_ft,
"charge_weight_lb": s.charge_weight_lb,
"scaled_distance": s.scaled_distance,
},
)
def _s4_ref(ref: Any, serial: str) -> EventRef:
peaks = ref.peaks_ips or {}
return EventRef(
event_id=make_event_id(serial, ref.key, stamp_of(ref.timestamp)),
serial=serial, series=4, index=ref.index, timestamp=iso_of(ref.timestamp),
record_type=ref.record_type, peak_vector_sum_ips=ref.peak_vector_sum_ips,
peaks_ips={k.lower(): v for k, v in peaks.items() if k in ("Tran", "Vert", "Long")},
filename=ref.filename,
detail={"size_bytes": ref.size, "mic": peaks.get("Mic"), "setup": ref.setup,
"sensor_location": ref.sensor_location},
)
def s4_list_events(client: Any, serial: str) -> EventList:
return EventList(serial=serial, series=4,
events=[_s4_ref(r, serial) for r in client.list_events(with_records=True)])
def s4_download_event(client: Any, serial: str, key: bytes, stamp: Optional[str]) -> DownloadedEvent:
"""Walk to the event and download it there -- the order THOR uses, the only
one captured. Downloading at a parked cursor has never been tried."""
for ref in client.iter_events(with_records=True):
if ref.key != key:
continue
found = stamp_of(ref.timestamp)
if stamp is not None and found != stamp:
raise StaleEvent(
f"the event at {key.hex()} on {serial} is from {found}, not {stamp} -- "
"the unit was erased or wrapped since the list was read; list again")
if ref.filename is None:
raise MalformedReply(
f"event {key.hex()}: its record gave no type or timestamp, so it cannot be named or stored")
# THOR's chunk size. A 16 KB chunk takes ~7 s on cellular against the
# 10 s receive deadline; 1 KB is what THOR itself sends.
blob, result = client.fetch_event(ref, chunk_size=THOR_CHUNK_SIZE)
err = client.decode_error(ref, result)
return DownloadedEvent(
event_id=make_event_id(serial, key, found), serial=serial, series=4,
filename=ref.filename, verified=True if err is not None else None,
idf_bytes=blob, timestamp=ref.timestamp,
record={"peak_vector_sum_ips": ref.peak_vector_sum_ips,
"sensor_location": ref.sensor_location, "setup": ref.setup},
detail={"size_bytes": ref.size, "pvs_error": err},
)
raise EventNotFound(f"no event {key.hex()} on {serial} -- list the events again")
-20
View File
@@ -1,20 +0,0 @@
"""Which series a unit is, from its serial prefix (decided with Brian, 2026-10-20)."""
from __future__ import annotations
from .errors import BadRequest
SERIES_BY_PREFIX = {"UM": 4, "BE": 3, "BA": 3}
def normalise_serial(serial: str) -> str:
return (serial or "").strip().upper()
def series_for_serial(serial: str) -> int:
s = normalise_serial(serial)
for prefix, series in SERIES_BY_PREFIX.items():
if s.startswith(prefix) and len(s) > len(prefix):
return series
raise BadRequest(
f"unknown serial {serial!r}: expected UM... (Series 4) or BE.../BA... (Series 3)"
)
+4 -44
View File
@@ -12,11 +12,8 @@ Layout written to `<filename>.h5`:
├─ samples_int16/ (optional)
│ ├─ Tran (int16, raw ADC counts) shape: (N,)
│ └─ ... per channel (only when present in the source)
├─ sensor_check/ (optional, schema v2+)
│ ├─ Tran (int32, raw counts) shape: (M,) M ≪ N
│ └─ ... per channel present in the source (MicL absent on 3-channel units)
└─ root attrs (event metadata):
schema_version int = 2
schema_version int = 1
kind str = "sfm.event.hdf5"
serial str
waveform_key str (8-hex)
@@ -67,7 +64,7 @@ from minimateplus.models import Event
log = logging.getLogger(__name__)
SCHEMA_VERSION = 2 # v2 adds the optional /sensor_check group
SCHEMA_VERSION = 1
HDF5_KIND = "sfm.event.hdf5"
# Geophone full-scale velocity per range (in/s). Confirmed in CLAUDE.md
@@ -273,22 +270,6 @@ def write_event_hdf5(
)
igrp.attrs["mic_psi_per_count"] = float(mic_factor)
# /sensor_check — optional short diagnostic self-check traces (schema
# v2+). Raw ADC counts (a shape diagnostic; the per-series count scale
# differs, and the renderer fits each trace to its box). Only channels
# the decoder found are written — 3-channel units carry no MicL.
sc = event.sensor_check or {}
if sc:
scgrp = f.create_group("sensor_check")
for ch in ("Tran", "Vert", "Long", "MicL"):
vals = sc.get(ch)
if vals:
scgrp.create_dataset(
ch, data=np.asarray(vals, dtype=np.int32),
compression="gzip", compression_opts=4, shuffle=True,
)
scgrp.attrs["units"] = "raw_counts"
import os
os.replace(tmp, path)
@@ -353,16 +334,6 @@ def read_event_hdf5(path: Union[str, Path]) -> dict:
if mic_attr is not None:
mic_psi = float(mic_attr)
# /sensor_check — optional (schema v2+); absent on older files.
sensor_check = None
scgrp = f.get("sensor_check")
if scgrp is not None:
sensor_check = {}
for ch in ("Tran", "Vert", "Long", "MicL"):
ds = scgrp.get(ch)
if ds is not None:
sensor_check[ch] = np.asarray(ds[()])
return {
"schema_version": sv,
"kind": attrs.get("kind"),
@@ -370,7 +341,6 @@ def read_event_hdf5(path: Union[str, Path]) -> dict:
"samples": samples,
"samples_int16": samples_int16,
"mic_psi_per_count": mic_psi,
"sensor_check": sensor_check,
}
@@ -461,16 +431,11 @@ def plot_json_from_hdf5(
event_id: Optional[str] = None,
index: Optional[int] = None,
) -> dict:
"""Build a `sfm.plot.v1` JSON dict from a stored .h5 file.
The dict also carries a top-level ``sensor_check`` key (the raw self-check
traces as ``{ch: [int]}``, or None) beyond the plot schema, so report
generation can read the traces from the same single .h5 load.
"""
"""Build a `sfm.plot.v1` JSON dict from a stored .h5 file."""
data = read_event_hdf5(path)
a = data["attrs"]
s = data["samples"]
out = _build_plot_dict(
return _build_plot_dict(
n_samples=len(s["Tran"]) if "Tran" in s else 0,
sample_rate=int(a.get("sample_rate", 1024) or 1024),
pretrig_samples=int(a.get("pretrig_samples", 0) or 0),
@@ -498,11 +463,6 @@ def plot_json_from_hdf5(
event_id=event_id,
index=index,
)
scd = data.get("sensor_check")
out["sensor_check"] = (
{ch: v.tolist() for ch, v in scd.items()} if scd else None
)
return out
def _build_plot_dict(
-128
View File
@@ -1,128 +0,0 @@
"""Store an event SFM downloaded from a unit -- the SDM side of
POST /device/events/download.
Both series end in the two writes every other ingest path makes: the waveform
store (file + sidecar + .h5) and SeismoDb.insert_events().
An event already stored -- by an earlier download, or by THOR's watcher or
Blastware's ACH -- is returned as it is and NOTHING is written. The watcher's
copy is the richer one (its paired report carries PVS, project strings and ZC
frequencies a bare download does not), so a download never merges into it or
replaces it.
"""
from __future__ import annotations
import datetime
from pathlib import Path
from typing import Any, Optional
from sfm.device_access.models import DownloadedEvent, EventDownload
class IngestError(Exception):
"""Downloaded from the unit, but could not be stored."""
def backfill_series3_event(ev: Any, cc: Any) -> None:
"""Compliance-config values that supersede what the 5A stream decoded.
Some STRT fields have ambiguous semantics (STRT[20] is rectime, but
STRT[8:10] / STRT[16:18] are device-specific scratch, not reliable sample or
pre-trigger counts). Shared with GET /device/event/{i}/blastware_file.
"""
if not cc:
return
if ev.sample_rate is None and cc.sample_rate:
ev.sample_rate = cc.sample_rate
if cc.record_time:
# Authoritative: the user-set value the unit followed when recording.
ev.rectime_seconds = cc.record_time
# Derive total_samples from sample_rate x rectime when we can; the
# STRT-derived value can land at a buffer offset rather than a count.
if ev.sample_rate and ev.rectime_seconds:
derived = int(round(ev.sample_rate * ev.rectime_seconds))
if (ev.total_samples is None
or ev.total_samples > derived * 2
or ev.total_samples < derived // 4):
ev.total_samples = derived
def _event_dt(ev: Any) -> Optional[datetime.datetime]:
ts = getattr(ev, "timestamp", None)
try:
return datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
except Exception: # noqa: BLE001
return None
def _already_stored(dl: DownloadedEvent, row: dict) -> EventDownload:
return EventDownload(
event_id=dl.event_id, serial=dl.serial, series=dl.series, db_event_id=row["id"],
stored_filename=row.get("blastware_filename") or "",
filesize=row.get("blastware_filesize"),
sha256=None, # the events table does not keep one
inserted=False, verified=dl.verified,
detail={**dl.detail, "already_stored": True},
)
def _overlay_s4_record(ev: Any, record: dict) -> None:
"""Fill, where the file left them empty, what the unit's 0x0C said.
Without Thor's TXT report the IDF file gives only the three PPVs. The
vector sum matters beyond display: find_twins matches on it. Not the mic:
its 0x0C decode reads a denormal (parked).
"""
from minimateplus.models import PeakValues, ProjectInfo
pvs = record.get("peak_vector_sum_ips")
if pvs is not None:
if ev.peak_values is None:
ev.peak_values = PeakValues()
if ev.peak_values.peak_vector_sum is None:
ev.peak_values.peak_vector_sum = pvs
location = record.get("sensor_location")
if location is not None:
if ev.project_info is None:
ev.project_info = ProjectInfo()
if ev.project_info.sensor_location is None:
ev.project_info.sensor_location = location
def persist_download(dl: DownloadedEvent, *, store: Any, db: Any) -> EventDownload:
# Never merge: a row for (serial, timestamp) means the event is stored, and
# whoever stored it first keeps it. No store call, no insert, no sidecar.
if dl.timestamp is not None:
rows = db.query_events(serial=dl.serial, from_dt=dl.timestamp, to_dt=dl.timestamp, limit=1)
if rows:
return _already_stored(dl, rows[0])
if dl.series == 4:
ev, rec = store.save_imported_idf(dl.idf_bytes, source_path=Path(dl.filename),
serial_hint=dl.serial)
if ev is not None:
_overlay_s4_record(ev, dl.record)
family = "series4"
else:
ev = dl.event
if ev is None:
raise IngestError(f"{dl.filename}: the download carried no event; nothing was stored")
backfill_series3_event(ev, dl.compliance)
geo_range = getattr(dl.compliance, "geo_range", None) if dl.compliance else None
rec = store.save(ev, serial=dl.serial, a5_frames=dl.a5_frames,
geo_range=geo_range if geo_range is not None else "normal")
family = "series3"
if ev is None or ev._waveform_key is None:
raise IngestError(f"{dl.filename}: stored the file but could not build a database row")
inserted, _skipped = db.insert_events(
[ev], serial=dl.serial,
waveform_records={ev._waveform_key.hex(): rec}, device_family=family)
row_id = None
dt = _event_dt(ev)
if dt is not None:
rows = db.query_events(serial=dl.serial, from_dt=dt, to_dt=dt, limit=1)
row_id = rows[0]["id"] if rows else None
return EventDownload(
event_id=dl.event_id, serial=dl.serial, series=dl.series, db_event_id=row_id,
stored_filename=rec["filename"], filesize=rec["filesize"], sha256=rec.get("sha256"),
inserted=inserted > 0, verified=dl.verified, detail=dict(dl.detail),
)
+45 -181
View File
@@ -121,13 +121,6 @@ class ReportData:
t0_ms: Optional[float] = None
dt_ms: Optional[float] = None
# Sensor self-check traces — {ch: [samples]} in raw counts, read from the
# standardized .h5 (/sensor_check group, schema v2+) where the per-series
# decoder stored them at ingest. The little diagnostic waveforms BW draws
# in its "Sensor Check" strip. Empty when absent (pre-v2 .h5, histogram,
# or 3-channel unit's MicL).
sensor_check_waveforms: dict = field(default_factory=dict)
# Record-type discriminator
record_type: Optional[str] = None
is_histogram: bool = False
@@ -253,8 +246,6 @@ def gather_report_data(
"peak_accel_g": ch.get("peak_accel_g"),
"peak_disp_in": ch.get("peak_disp_in"),
"sensor_check": sc_ch.get("result"),
"sc_freq_hz": sc_ch.get("freq_hz"),
"sc_ratio": sc_ch.get("ratio"),
"peak_date": peak_date,
"peak_time": peak_time,
})
@@ -296,12 +287,6 @@ def gather_report_data(
rd.pretrig_samples = ta.get("pretrig_samples")
rd.t0_ms = ta.get("t0_ms")
rd.dt_ms = ta.get("dt_ms")
# Sensor self-check traces — read from the standardized .h5 (schema
# v2+). Device-agnostic: whichever decoder produced the event
# stored them at ingest, so SFM reads them here without knowing or
# caring about the source instrument series. Empty on pre-v2 files
# (until backfilled) and on 3-channel / histogram events.
rd.sensor_check_waveforms = wf.get("sensor_check") or {}
except Exception as exc:
log.warning("gather_report_data: hdf5 read failed: %s", exc)
@@ -411,34 +396,9 @@ def _render_waveform_layout(fig, rd: ReportData) -> None:
ax_stats = fig.add_subplot(gs[2]); ax_stats.axis("off")
_draw_channel_stats_waveform(ax_stats, rd)
_draw_compliance_panel(fig, rd)
_draw_waveform_subplot(fig, gs[3], rd)
# Compliance-chart placement, in figure fractions. Measured directly off a
# Blastware Event Report PDF (ref-stuff/n844lqhbzt0w_bw_pdf.pdf) so the chart
# matches BW's size and position: it spans from just under the header down
# through the stats band, hard against the right page margin. The left edge
# leaves room for the y-axis tick labels + "Velocity (in/s)" title, which the
# compacted stats table (see _draw_channel_stats_waveform) is sized to clear.
_COMPLIANCE_BOX = (0.489, 0.502, 0.951, 0.867) # x0, y0, x1, y1
def _draw_compliance_panel(fig, rd: ReportData) -> None:
"""Large USBM RI8507 compliance chart in the upper-right, sized and
positioned to match Blastware's Event Report (see _COMPLIANCE_BOX)."""
x0, y0, x1, y1 = _COMPLIANCE_BOX
fig.text((x0 + x1) / 2, y1 + 0.006, "USBM RI8507 And OSMRE", fontsize=9,
weight="bold", color="#333", ha="center", va="bottom")
if rd.channels and rd.sample_rate_sps:
from sfm.compliance import draw_compliance_chart
ax = fig.add_axes([x0, y0, x1 - x0, y1 - y0])
draw_compliance_chart(ax, rd.channels, rd.sample_rate_sps)
else:
fig.text((x0 + x1) / 2, (y0 + y1) / 2, "(no waveform data)", fontsize=8,
color="#bbb", ha="center", va="center", style="italic")
def _render_histogram_layout(fig, rd: ReportData) -> None:
"""Histogram layout: header / mic-only / per-channel stats / bar plot.
@@ -517,11 +477,11 @@ def _split_iso_to_date_time(iso: Optional[str]) -> tuple[Optional[str], Optional
return (None, None)
def _kv(ax, x, y, label, value, *, label_w=0.18, fontsize=8):
def _kv(ax, x, y, label, value, *, label_w=0.18):
"""Render a 'Label Value' row at axes-coordinates (x, y)."""
ax.text(x, y, label, fontsize=fontsize, color="#555", ha="left", va="top",
ax.text(x, y, label, fontsize=8, color="#555", ha="left", va="top",
transform=ax.transAxes)
ax.text(x + label_w, y, _fmt(value), fontsize=fontsize, ha="left", va="top",
ax.text(x + label_w, y, _fmt(value), fontsize=8, ha="left", va="top",
transform=ax.transAxes, family="monospace")
@@ -584,17 +544,14 @@ def _draw_header_columns(ax, rows_left, rd: ReportData) -> None:
("File Name", rd.file_name),
("Post Event Notes", rd.post_event_notes),
]
# fontsize 7.5 (BW's header is a touch smaller than our body text) + a
# tighter right-column value indent so the long serial+firmware line
# ("BE##### V ##.##-#.## MiniMate Plus") fits without running off the page.
y = 0.95
dy = 0.095
for label, value in rows_left:
_kv(ax, 0.0, y, label, value, label_w=0.18, fontsize=7.5)
_kv(ax, 0.0, y, label, value, label_w=0.18)
y -= dy
y = 0.95
for label, value in rows_right:
_kv(ax, 0.55, y, label, value, label_w=0.14, fontsize=7.5)
_kv(ax, 0.55, y, label, value, label_w=0.20)
y -= dy
@@ -617,14 +574,19 @@ def _draw_mic_and_usbm(ax, rd: ReportData) -> None:
transform=ax.transAxes, va="top")
rows = _mic_rows(rd)
y = 0.80
# Tighter label indent + slightly smaller font so the long "Channel Test
# Passed (Freq = … Amp = … mv)" line clears the enlarged compliance chart's
# left edge (_COMPLIANCE_BOX) instead of running behind it.
for label, value in rows:
_kv(ax, 0.0, y, label, value, label_w=0.13, fontsize=7)
_kv(ax, 0.0, y, label, value, label_w=0.18)
y -= 0.15
# The USBM compliance chart is drawn as its own large square panel spanning
# the mic + stats rows on the right — see _draw_compliance_panel().
# USBM chart placeholder — upper-right. Real piecewise compliance
# curves are a separate work item; for now this just shows the title
# + a "see report" message so the layout is correct.
ax.text(0.72, 0.97, "USBM RI8507 And OSMRE",
fontsize=9, weight="bold", color="#333", ha="center", va="top",
transform=ax.transAxes)
ax.text(0.72, 0.50, "[compliance chart\ncoming soon]",
fontsize=8, color="#bbb", ha="center", va="center",
transform=ax.transAxes, style="italic")
def _mic_rows(rd: ReportData) -> list[tuple[str, Optional[str]]]:
@@ -674,18 +636,8 @@ def _draw_channel_stats_waveform(ax, rd: ReportData) -> None:
("Peak Acceleration", "peak_accel_g", "g"),
("Peak Displacement", "peak_disp_in", "in"),
("Sensor Check", "sensor_check", ""),
# Sensor-check sub-rows (indented under "Sensor Check", like BW): the
# geophone ring-down frequency + overswing ratio from the self-check.
(" Frequency", "sc_freq_hz", "Hz"),
(" Overswing Ratio", "sc_ratio", ""),
]
# Compacted to the left half so the enlarged compliance chart (BW-sized,
# right against the page margin) has room — see _COMPLIANCE_BOX.
_draw_stats_table(
ax, rd, rows_spec,
bbox_width=0.42, fontsize=7.5,
col_widths=[0.185, 0.065, 0.065, 0.065, 0.040],
)
_draw_stats_table(ax, rd, rows_spec)
_draw_pvs_summary(ax, rd, n_data_rows=len(rows_spec))
@@ -746,39 +698,19 @@ def _draw_pvs_summary(
table_bottom_y = getattr(ax, "_stats_table_bottom", -0.10)
pvs_y = table_bottom_y - 0.04 # small gap below the table border
# Centered under the stats table for visual balance — looks intentional
# rather than offset. When the table is compacted (waveform layout), it
# occupies only the left portion of the axes, so center on the table's
# width rather than the full axes (which would push the line under the
# compliance chart). The original BW-replica had a "NA: Not Applicable"
# caption below this line; dropped because we use "—" for missing values.
table_w = getattr(ax, "_stats_table_width", 0.80)
if table_w < 0.79:
# Compacted (waveform) layout: left-align under the table, one point
# smaller, so the line clears the enlarged compliance chart's
# bottom-left tick labels on the right.
ax.text(0.0, pvs_y, line, fontsize=8, weight="bold",
ha="left", va="top", transform=ax.transAxes)
else:
ax.text(0.5, pvs_y, line, fontsize=9, weight="bold",
ha="center", va="top", transform=ax.transAxes)
# Centered for visual balance — looks intentional rather than offset.
# The original BW-replica had a "NA: Not Applicable" caption below
# this line; dropped because we use "—" for missing values and the
# legend was always squished against the PVS line.
ax.text(0.5, pvs_y, line, fontsize=9, weight="bold",
ha="center", va="top", transform=ax.transAxes)
def _draw_stats_table(
ax, rd: ReportData, rows_spec: list[tuple[str, str, str]],
*, bbox_width: float = 0.80, fontsize: float = 8,
col_widths: Optional[list[float]] = None,
) -> None:
def _draw_stats_table(ax, rd: ReportData, rows_spec: list[tuple[str, str, str]]) -> None:
"""Render a per-channel stats table (Tran/Vert/Long).
rows_spec: list of (label, field_name_in_channel_stats, unit_string)
``bbox_width`` / ``col_widths`` / ``fontsize`` let a caller compact the
table (the waveform layout packs it into the left half to clear the
compliance chart; the histogram layout keeps the wider defaults).
"""
if col_widths is None:
col_widths = [0.28, 0.14, 0.14, 0.14, 0.10]
headers = ["", "Tran", "Vert", "Long", ""]
ch_lookup = {c["name"]: c for c in rd.channel_stats}
@@ -794,8 +726,6 @@ def _draw_stats_table(
if field == "zc_freq_hz":
prefix = ">" if ch_rec.get("zc_freq_above_range") else ""
return f"{prefix}{val:.0f}"
if field in ("sc_freq_hz", "sc_ratio"):
return f"{val:.1f}" # BW shows 1 decimal (7.5 Hz, 3.6)
return f"{val:.3f}"
return str(val)
@@ -820,17 +750,16 @@ def _draw_stats_table(
table_bottom = 1.0 - table_height
tbl = ax.table(
cellText=table_data,
colWidths=col_widths,
colWidths=[0.28, 0.14, 0.14, 0.14, 0.10],
cellLoc="left", edges="open",
bbox=[0.0, table_bottom, bbox_width, table_height],
bbox=[0.0, table_bottom, 0.80, table_height],
)
tbl.auto_set_font_size(False)
tbl.set_fontsize(fontsize)
tbl.set_fontsize(8)
for j in range(5):
tbl[(0, j)].set_text_props(weight="bold", color="#555")
# Stash the bottom Y + width so _draw_pvs_summary can position itself.
# Stash the bottom Y so _draw_pvs_summary can position itself below.
ax._stats_table_bottom = table_bottom
ax._stats_table_width = bbox_width
def _channel_axis_color(ch: str) -> str:
@@ -840,59 +769,27 @@ def _channel_axis_color(ch: str) -> str:
def _draw_waveform_subplot(fig, gridspec_cell, rd: ReportData) -> None:
"""4-channel stacked waveform plot — Instantel printout order
(MicL on top, Tran on bottom), shared x-axis in SECONDS, trigger
triangle markers at t=0, '0.0' baseline label on right of each.
When sensor self-check traces are present (rd.sensor_check_waveforms), a
narrow "Sensor Check" strip of per-channel mini-plots is drawn to the right,
aligned to the lanes — matching Blastware's Event Report.
"""
from matplotlib.ticker import MaxNLocator
triangle markers at t=0, '0.0' baseline label on right of each."""
inner = gridspec_cell.subgridspec(4, 1, hspace=0.0)
order = ["MicL", "Long", "Vert", "Tran"]
has_sc = bool(rd.sensor_check_waveforms)
if has_sc:
# main lanes + a narrow sensor-check strip column, flush against the
# main panel (BW shares the border — no gap), with the "0.0" baseline
# labels moved to the right of the strip. Proportions match BW's
# Event Report (main ~0.75 / strip ~0.10 of the panel width).
inner = gridspec_cell.subgridspec(4, 2, width_ratios=[1.0, 0.13],
wspace=0.0, hspace=0.0)
else:
inner = gridspec_cell.subgridspec(4, 1, hspace=0.0)
sr = rd.sample_rate_sps or 1024
# Convert ms-based time axis to seconds for the x-axis
dt_s = (rd.dt_ms or (1000.0 / sr)) / 1000.0
t0_s = (rd.t0_ms if rd.t0_ms is not None else 0.0) / 1000.0
# Shared geo scale across Long/Vert/Tran (matches the event modal + BW's
# single amp/div): all three geo lanes use ONE Y scale = the max |sample|
# across them (padded, floored), so relative amplitudes stay honest instead
# of each lane auto-zooming to its own peak. Mic keeps its own (psi) scale.
GEO_FLOOR_INS = 0.05
_geo_amax = 0.0
for _gch in ("Long", "Vert", "Tran"):
for _x in (rd.channels.get(_gch) or []):
_a = abs(_x)
if _a > _geo_amax:
_geo_amax = _a
geo_shared = max(_geo_amax * 1.10, GEO_FLOOR_INS)
main_axes = []
sc_axes = []
last_idx = len(order) - 1
for i, ch in enumerate(order):
ax = fig.add_subplot(inner[i, 0] if has_sc else inner[i])
main_axes.append(ax)
ax = fig.add_subplot(inner[i])
values = rd.channels.get(ch) or []
times = [t0_s + j * dt_s for j in range(len(values))]
if values:
color = _channel_axis_color(ch)
ax.plot(times, values, color=color, linewidth=0.5)
# Geo: one shared symmetric scale (honest relative amplitudes).
# Mic: symmetric on its own psi scale (different unit).
# Symmetric y-axis for geo; zero-anchored for mic.
if ch != "MicL":
ax.set_ylim(-geo_shared, geo_shared)
amax = max((abs(v) for v in values), default=0.001)
ax.set_ylim(-amax * 1.10, amax * 1.10)
else:
amax = max((abs(v) for v in values), default=0.001)
ax.set_ylim(-amax * 1.10, amax * 1.10)
@@ -900,12 +797,9 @@ def _draw_waveform_subplot(fig, gridspec_cell, rd: ReportData) -> None:
# Channel label on the LEFT (matches BW)
ax.set_ylabel(ch, fontsize=8, rotation=0, ha="right", va="center",
color=_channel_axis_color(ch), weight="bold", labelpad=14)
# "0.0" baseline label on the RIGHT (BW convention). With the sensor-
# check strip attached, it goes to the right of the STRIP (drawn below);
# otherwise just outside the main lane.
if not has_sc:
ax.text(1.005, 0.5, "0.0", transform=ax.transAxes,
fontsize=7, color="#555", va="center", ha="left")
# "0.0" on the RIGHT (BW convention)
ax.text(1.005, 0.5, "0.0", transform=ax.transAxes,
fontsize=7, color="#555", va="center", ha="left")
ax.grid(True, linestyle="--", linewidth=0.3, color="#bbb", alpha=0.6)
# Vertical dashed trigger line at t=0
@@ -920,53 +814,23 @@ def _draw_waveform_subplot(fig, gridspec_cell, rd: ReportData) -> None:
else:
ax.tick_params(axis="x", labelsize=7)
ax.tick_params(axis="y", labelsize=6)
# Stacked lanes touch, so the top/bottom y-tick labels of adjacent lanes
# would overprint at the shared boundary. Prune the extreme ticks so
# each boundary shows clean interior ticks (0.5 / 0.0 / -0.5) only.
ax.yaxis.set_major_locator(MaxNLocator(nbins=4, prune="both"))
# Sensor self-check mini-plot in the right strip (aligned to this lane).
if has_sc:
scx = fig.add_subplot(inner[i, 1])
sc_axes.append(scx)
sc_vals = rd.sensor_check_waveforms.get(ch) or []
if sc_vals:
_col = _channel_axis_color(ch)
# Faint zero baseline (BW draws the channel baseline through the
# strip) — reference for the one-sided geophone ring-downs.
scx.axhline(0.0, color=_col, linewidth=0.3, alpha=0.4)
scx.plot(range(len(sc_vals)), sc_vals, color=_col, linewidth=0.5)
# Fit the trace to the box (BW-style) rather than a symmetric
# scale: the geo self-checks are one-sided dips, so a symmetric
# scale would strand them in the bottom half with an empty top.
_lo, _hi = min(sc_vals), max(sc_vals)
_pad = 0.10 * ((_hi - _lo) or 1.0)
scx.set_ylim(_lo - _pad, _hi + _pad)
scx.set_xticks([]); scx.set_yticks([])
for _s in scx.spines.values():
_s.set_linewidth(0.4); _s.set_color("#999")
# "0.0" baseline label to the RIGHT of the strip (BW convention)
scx.text(1.10, 0.5, "0.0", transform=scx.transAxes,
fontsize=7, color="#555", va="center", ha="left")
# Trigger triangle marker ▼ above the top channel at t=0
top_ax = main_axes[0] # MicL
top_ax = fig.axes[-4] # MicL is the first added in this gridspec
top_ax.plot([0], [top_ax.get_ylim()[1]], marker="v", color="black",
markersize=8, clip_on=False, zorder=10)
# "Sensor Check" caption under the strip (BW convention)
if has_sc and sc_axes:
pos = sc_axes[-1].get_position()
fig.text((pos.x0 + pos.x1) / 2, pos.y0 - 0.012, "Sensor Check",
fontsize=7, color="#555", ha="center", va="top")
# Compute scale-per-division for the footer (10 divs across the chart)
# and find peak geo amplitude for the geo amp/div setting.
total_s = times[-1] - times[0] if values else 0
div_s = total_s / 10 if total_s > 0 else 0
# Footer div value reflects the SHARED geo scale (so it's correct for all
# three lanes, not just whichever one happened to be checked first).
geo_amp_div = f"{(geo_shared * 2) / 10:.3f}" if _geo_amax > 0 else "—"
geo_amp_div = "—"
for ch in ("Tran", "Vert", "Long"):
v = rd.channels.get(ch) or []
if v:
amax = max(abs(x) for x in v)
geo_amp_div = f"{(amax * 1.1 * 2) / 10:.3f}"
break
fig.text(
0.11, 0.030,
f"Time(Seconds) {div_s:.2f} sec/div Amplitude Geo: {geo_amp_div} in/s/div Mic: 0.001 psi(L)/div",
+28 -180
View File
@@ -13,14 +13,6 @@ GET /device/info POLL + serial number + full config read
GET /device/events Download all stored events (headers + peak values)
POST /device/connect Explicit connect/identify (same as /device/info)
GET /device/event/{idx} Single event by index (header + waveform record)
GET /device/settings Recording settings (requires serial)
POST /device/hangup Hang up a held Series-4 line
`serial` on /device/info, /device/connect, /device/monitor/status and
/device/settings names the unit (UM... = Series 4, BE.../BA... = Series 3) and
returns the shared model. Without it, the legacy Series-3 behaviour is
unchanged. Series-4 lines are held open between requests and hung up after
5 idle minutes, on POST /device/hangup, or the moment the unit calls home.
Transport query params (supply one set):
Serial (direct RS-232 cable):
@@ -50,7 +42,7 @@ import tempfile
import threading
import time
from pathlib import Path
from typing import Mapping, Optional
from typing import Optional
# FastAPI / Pydantic
try:
@@ -82,11 +74,6 @@ from sfm.database import SeismoDb
from sfm.live_cache import LiveCache as _LiveCache
from sfm.waveform_store import WaveformStore
from sfm import db_snapshot
from sfm.event_ingest import backfill_series3_event, persist_download
import dataclasses
from sfm.device_access import DeviceAccess, DeviceError, UnitAddress
from sfm.device_access.errors import BadRequest
from sfm.device_access.series import normalise_serial
logging.basicConfig(
level=logging.INFO,
@@ -353,82 +340,6 @@ def _run_with_retry(fn, *, is_tcp: bool):
return fn() # let any second failure propagate normally
# ── Device access (serial-named requests) ─────────────────────────────────────
# A request that names the unit by `serial` goes through sfm.device_access:
# same contract for Series 3 and 4. Without `serial`, handlers run their
# legacy Series-3 path unchanged (spec 2026-10-20).
# Constructing it does no I/O and starts no thread until a Series-4 session exists.
_device_access_instance: DeviceAccess = DeviceAccess()
def _device_access() -> DeviceAccess:
return _device_access_instance
def _unit_address(port: Optional[str], baud: Optional[int], host: Optional[str],
tcp_port: int) -> UnitAddress:
return UnitAddress(host=host, tcp_port=tcp_port if host else None,
port=None if host else port, baud=baud)
def _via_device_access(fn) -> dict:
try:
result = fn()
except DeviceError as exc:
raise HTTPException(status_code=exc.http_status, detail=str(exc)) from exc
return dataclasses.asdict(result) if dataclasses.is_dataclass(result) else result
_SERIAL_AWARE_PATHS = frozenset({
"/device/info", "/device/connect", "/device/monitor/status", "/device/settings",
"/device/events", "/device/events/download",
})
def _device_guard(path: str, query: Mapping[str, str]) -> Optional[tuple]:
"""Refuse a /device/* request that would reach the wrong series' code.
FastAPI drops query params a route does not declare, so `?serial=UM...` on
a Series-3 route would silently run Series-3 bytes against a Micromate
(0xA2 is CONFIRM ERASE there). Returns (status, detail) to refuse, or None.
/device/hangup is always allowed: it must always be able to release a line.
"""
if not path.startswith("/device/") or path == "/device/hangup":
return None
serial = normalise_serial(query.get("serial") or "")
if serial and path in _SERIAL_AWARE_PATHS:
return None # DeviceAccess routes by series and checks held lines itself
if serial.startswith("UM"):
return 501, f"not supported for Series 4 yet: {path}"
# Everything else runs the legacy Series-3 handler -- whatever serial it
# carried, FastAPI drops it -- so it must not reach a held Series-4 line.
if not (query.get("host") or query.get("port")):
return None
try:
tcp_port = int(query.get("tcp_port") or DEFAULT_TCP_PORT)
# baud is not part of the address key, so it is not parsed here.
addr = _unit_address(query.get("port") or None, None, query.get("host") or None, tcp_port)
except (BadRequest, ValueError):
return None
held = _device_access().held_serial(addr)
if held is not None:
return 409, (f"a Series-4 line to {held} is held at {addr.key}; "
"POST /device/hangup first")
return None
@app.middleware("http")
async def _device_guard_middleware(request, call_next):
refusal = _device_guard(request.url.path, request.query_params)
if refusal is not None:
return JSONResponse(status_code=refusal[0], content={"detail": refusal[1]})
return await call_next(request)
_SERIAL_DOC = "Unit serial -- UM... (Series 4) or BE.../BA... (Series 3). Returns the shared model."
# ── Helpers ────────────────────────────────────────────────────────────────────
def _backfill_events(events: list, info: "DeviceInfo") -> None:
@@ -493,11 +404,10 @@ def event_browser():
@app.get("/device/info")
def device_info(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5, /dev/ttyUSB0)"),
baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
baud: int = Query(38400, description="Serial baud rate (default 38400)"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay (e.g. 203.0.113.5)"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
force: bool = Query(False, description="Bypass cache and re-read from device"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
) -> dict:
"""
Connect to the device, perform the POLL startup handshake, and return
@@ -511,10 +421,6 @@ def device_info(
and re-read directly from the device (e.g. after a config push).
The cache is also automatically invalidated after POST /device/config.
"""
if serial:
return _via_device_access(
lambda: _device_access().identify(_unit_address(port, baud, host, tcp_port), serial))
baud = 38400 if baud is None else baud
log.info("GET /device/info port=%s host=%s tcp_port=%d force=%s", port, host, tcp_port, force)
cache = get_cache()
@@ -553,39 +459,27 @@ def device_info(
@app.post("/device/connect")
def device_connect(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
) -> dict:
"""
Connect to the device and return identity. POST variant for terra-view
compatibility with the SLMM proxy pattern.
"""
# force=True PRESERVES today's behaviour: the old call omitted `force`, so it
# received FastAPI's Query(False) object, which is truthy -- /device/connect
# has always bypassed the cache. Passing False here would quietly change that.
return device_info(port=port, baud=baud, host=host, tcp_port=tcp_port,
force=True, serial=serial)
return device_info(port=port, baud=baud, host=host, tcp_port=tcp_port)
@app.get("/device/events")
def device_events(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
debug: bool = Query(False, description="Include raw record hex for field-layout inspection"),
force: bool = Query(False, description="Bypass cache and re-download all events from device"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
) -> dict:
"""
**With `serial`** (UM... or BE.../BA...): the unit's events in the shared
shape for either series, read from headers only -- no event is downloaded
to list it -- and not cached. Each carries an `event_id` for
POST /device/events/download. Without `serial`, the legacy Series-3
behaviour below.
Connect to the device, read the event index, and download all stored
events (event headers + full waveform records with peak values).
@@ -608,10 +502,6 @@ def device_events(
If new events exist on the device, only the new ones are downloaded and merged.
Pass *force=true* to bypass the cache entirely and re-download everything.
"""
if serial:
return _via_device_access(
lambda: _device_access().list_events(_unit_address(port, baud, host, tcp_port), serial))
baud = 38400 if baud is None else baud
log.info("GET /device/events port=%s host=%s debug=%s force=%s", port, host, debug, force)
cache = get_cache()
@@ -1013,7 +903,28 @@ def device_event_blastware_file(
if serial != "UNKNOWN" and ev._waveform_key is not None:
try:
cc = info.compliance_config
backfill_series3_event(ev, cc)
# Backfill authoritative compliance-config values onto the
# Event before persisting. These supersede whatever
# _decode_a5_waveform read from the STRT bytes (some of which
# have ambiguous semantics — e.g. STRT[20] is rectime but
# STRT[8:10] / STRT[16:18] are device-specific scratch fields
# that aren't reliable sample/pretrig counts).
if cc:
if ev.sample_rate is None and cc.sample_rate:
ev.sample_rate = cc.sample_rate
if cc.record_time:
# record_time from compliance is authoritative — the
# user-set value the device followed when recording.
ev.rectime_seconds = cc.record_time
# Derive total_samples from sample_rate × rectime when
# we can; the STRT-derived value can land at a buffer-
# offset rather than a sample count.
if ev.sample_rate and ev.rectime_seconds:
derived = int(round(ev.sample_rate * ev.rectime_seconds))
if (ev.total_samples is None
or ev.total_samples > derived * 2
or ev.total_samples < derived // 4):
ev.total_samples = derived
geo_range = getattr(cc, "geo_range", None) if cc else None
rec = _get_store().save(
ev, serial=serial, a5_frames=a5_frames,
@@ -1188,11 +1099,10 @@ def device_config_project(
@app.get("/device/monitor/status")
def device_monitor_status(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
force: bool = Query(False, description="Bypass cache and re-read from device"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
) -> dict:
"""
Read monitoring status from the device.
@@ -1208,10 +1118,6 @@ def device_monitor_status(
**Caching**: status is cached for 30 seconds to reduce cellular polling overhead.
Pass *force=true* to bypass the cache for an immediate fresh read.
"""
if serial:
return _via_device_access(
lambda: _device_access().status(_unit_address(port, baud, host, tcp_port), serial))
baud = 38400 if baud is None else baud
cache = get_cache()
conn_key = SFMCache.make_conn_key(host, tcp_port, port, baud)
@@ -1254,64 +1160,6 @@ def device_monitor_status(
return result
@app.get("/device/settings")
def device_settings(
serial: str = Query(..., description=_SERIAL_DOC),
port: Optional[str] = Query(None, description="Serial port (e.g. /dev/ttyACM0)"),
baud: Optional[int] = Query(None, description="Serial baud (default by series)"),
host: Optional[str] = Query(None, description="TCP host -- modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
"""The unit's recording settings, in the shared shape for either series."""
return _via_device_access(
lambda: _device_access().settings(_unit_address(port, baud, host, tcp_port), serial))
@app.post("/device/events/download")
def device_events_download(
serial: str = Query(..., description=_SERIAL_DOC),
event_id: str = Query(..., description="From GET /device/events?serial=..."),
port: Optional[str] = Query(None, description="Serial port (e.g. /dev/ttyACM0)"),
baud: Optional[int] = Query(None, description="Serial baud (default by series)"),
host: Optional[str] = Query(None, description="TCP host -- modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
"""Download one event, check it, and store it in SFM's database.
Read-only on the unit. The stored file and waveform are then at
/db/events/{db_event_id}/... . An event already stored -- by an earlier
download, or by THOR's watcher -- comes back as its existing row and
nothing is written (`inserted: false`, `detail.already_stored: true`).
The unit is busy for the whole download: other requests for it wait,
then get 423.
"""
try:
dl = _device_access().download_event(_unit_address(port, baud, host, tcp_port), serial, event_id)
except DeviceError as exc:
raise HTTPException(status_code=exc.http_status, detail=str(exc)) from exc
try:
out = persist_download(dl, store=_get_store(), db=_get_db())
except Exception as exc:
log.error("events/download: %s downloaded but not stored: %s", dl.event_id, exc, exc_info=True)
raise HTTPException(
status_code=500,
detail=f"downloaded {dl.filename} from the unit but could not store it: {exc}") from exc
return dataclasses.asdict(out)
@app.post("/device/hangup")
def device_hangup(
port: Optional[str] = Query(None, description="Serial port"),
baud: Optional[int] = Query(None, description="Serial baud"),
host: Optional[str] = Query(None, description="TCP host -- modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
"""Hang up a held line now instead of waiting for the idle timeout.
`hung_up` is false if nothing was being held."""
return _via_device_access(
lambda: {"hung_up": _device_access().hang_up(_unit_address(port, baud, host, tcp_port))})
@app.get("/device/events/storage_range")
def device_events_storage_range(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
+20 -295
View File
@@ -108,12 +108,6 @@
color: var(--text);
}
.btn-ghost:hover { border-color: var(--blue-lt); color: var(--blue-lt); }
.btn-danger { background: var(--red); color: #fff; }
.btn-danger:hover:not(:disabled) { filter: brightness(1.15); }
.diag-result { display:block; margin-top:6px; font-size:12px; opacity:.85;
white-space:pre-wrap; word-break:break-word; }
.diag-result.ok { color: var(--green); }
.diag-result.error { color: var(--red); }
.btn:disabled { background: var(--surface2) !important; color: var(--text-mute) !important; cursor: not-allowed; border-color: var(--border2) !important; }
/* #connect-btn styles moved to #live-connect-bar block */
@@ -916,7 +910,6 @@
<button class="tab-btn" data-tab="events" onclick="switchTab('events')">Events</button>
<button class="tab-btn" data-tab="config" onclick="switchTab('config')">Config</button>
<button class="tab-btn" data-tab="call-home" onclick="switchTab('call-home')">Call Home</button>
<button class="tab-btn" data-tab="diagnostics" onclick="switchTab('diagnostics')">Diagnostics</button>
</div>
<!-- ════════════════════════════════════════════════════════════════
@@ -945,10 +938,6 @@
<div id="tab-events" class="tab-pane" style="display:flex; flex-direction:column; overflow:hidden;">
<div class="event-toolbar">
<button class="btn btn-ghost" id="load-events-btn" onclick="loadEventList()" disabled
title="Walk the device's event chain and list its stored events. This is the slow one — it reads every event header over the cellular link.">
⟳ Load events
</button>
<button class="btn btn-ghost" id="load-btn" onclick="loadWaveform()" disabled>Load Waveform</button>
<button class="btn btn-ghost" id="save-btn" onclick="saveEventToDb()" disabled
title="Download the full waveform from the device and save it to the SFM database + waveform store. Honors the Force refresh toggle.">
@@ -1216,77 +1205,6 @@
</div><!-- end #tab-call-home -->
<!-- ════════════════════════════════════════════════════════════════
TAB: Diagnostics
═══════════════════════════════════════════════════════════════════ -->
<div id="tab-diagnostics" class="tab-pane">
<div class="cfg-grid">
<div class="cfg-section">
<div class="cfg-section-title">Device State</div>
<div class="hint" style="margin-bottom:10px">
Fast probes — POLL plus one read each, about 2 s. None of these walk the event chain.
</div>
<div class="dev-table" id="diag-table"></div>
<div class="cfg-actions" style="margin-top:12px">
<button class="btn btn-ghost" id="diag-refresh-btn" onclick="refreshDiagnostics()" disabled>Refresh</button>
<span id="diag-status"></span>
</div>
</div>
<div class="cfg-section">
<div class="cfg-section-title">Actions</div>
<div class="cfg-field">
<label>Stop Monitoring</label>
<button class="btn btn-ghost" id="diag-stop-btn" onclick="diagStopMonitoring()" disabled>Send Stop (SUB 0x97)</button>
<div class="hint">Halts recording. On a unit triggering continuously, this is what breaks the call-home loop.</div>
<span class="diag-result" id="diag-stop-result"></span>
</div>
<div class="cfg-field">
<label>Disable Auto Call Home</label>
<button class="btn btn-ghost" id="diag-ach-btn" onclick="diagDisableAch()" disabled>Disable ACH</button>
<div class="hint">Stored events are left untouched (<code>rescue?erase=false</code>). The unit stops dialing out until ACH is re-enabled.</div>
<span class="diag-result" id="diag-ach-result"></span>
</div>
<div class="cfg-field">
<label>Erase All Events</label>
<input type="text" id="diag-erase-confirm" placeholder="Type the serial to enable"
oninput="diagCheckEraseConfirm()" autocomplete="off" />
<button class="btn btn-danger" id="diag-erase-btn" onclick="diagEraseEvents()" disabled>Erase Events</button>
<div class="hint">⚠ Permanent, and resets the event chain to key <code>0x01110000</code>. Download anything worth keeping first.</div>
<span class="diag-result" id="diag-erase-result"></span>
</div>
</div>
<div class="cfg-section">
<div class="cfg-section-title">Unresponsive Unit</div>
<div class="hint" style="margin-bottom:10px">
The escalation ladder from <code>docs/runbooks/wedged_unit_recovery.md</code>, for a unit too busy
to answer normal request/response. Prefer <b>Method A</b> — point the modem at an
<code>ach_server</code> and answer its call — before racing it with these.
</div>
<div class="cfg-field">
<label>Slow drip <span class="hint" style="display:inline">(one held session, a stop every 3 s)</span></label>
<button class="btn btn-ghost" id="diag-drip-btn" onclick="diagSlowDrip()" disabled>Run 120 s drip</button>
<div class="hint">Success is <code>bytes_received &gt; 0</code>. A full duration with <code>send_error: null</code> is <b>not</b> success on its own.</div>
<span class="diag-result" id="diag-drip-result"></span>
</div>
<div class="cfg-field">
<label>Blind stop <span class="hint" style="display:inline">(fire-and-forget, one attempt)</span></label>
<button class="btn btn-ghost" id="diag-blind-btn" onclick="diagBlindStop()" disabled>Send blind stop</button>
<span class="diag-result" id="diag-blind-result"></span>
</div>
</div>
</div>
</div><!-- end #tab-diagnostics -->
</div><!-- end #section-live -->
<!-- ════════════════════════════════════════════════════════════════
@@ -1443,8 +1361,6 @@
// ── State ──────────────────────────────────────────────────────────────────────
let unitInfo = null;
let eventList = [];
let storageInfo = null; // /device/events/storage_range — cheap, read on connect
let eventsLoaded = false; // the event chain walk is opt-in; see loadEventList()
let currentEvent = 0;
let charts = {};
let geoAdcScale = 6.206;
@@ -1542,7 +1458,6 @@ function switchTab(name) {
if (name === 'units') { if (!unitsLoaded) loadUnits(); }
if (name === 'monlog') { if (!monlogLoaded) loadMonitorLog(); }
if (name === 'sessions') { if (!sessLoaded) loadSessions(); }
if (name === 'diagnostics' && devHost() && unitInfo) refreshDiagnostics();
}
// ── Connect ────────────────────────────────────────────────────────────────────
@@ -1563,13 +1478,18 @@ async function connectUnit() {
btn.disabled = false; btn.textContent = 'Connect'; return;
}
// Connecting deliberately does NOT walk the event chain. That walk reads
// every event header over the cellular link and can take minutes — or fail
// outright on a unit whose buffer has wrapped past 0xFFFF. Use the ~2 s
// probes instead; the event list is opt-in via loadEventList().
eventList = []; eventsLoaded = false;
setStatus('Reading device state…', 'loading');
storageInfo = await fetchJson(`/device/events/storage_range`).catch(() => null);
setStatus('Fetching event list…', 'loading');
try {
const r = await fetch(`${api()}/device/events?${deviceParams()}`);
if (!r.ok) { const e = await r.json().catch(() => ({})); throw new Error(e.detail || r.statusText); }
const evData = await r.json();
eventList = evData.events || [];
// Merge compliance from /device/events response (it re-reads it)
if (evData.device) unitInfo = { ...unitInfo, ...evData.device };
} catch (e) {
setStatus(`Event fetch failed: ${e.message}`, 'error');
btn.disabled = false; btn.textContent = 'Reconnect'; return;
}
populateDeviceBar();
populateDeviceTab();
@@ -1578,9 +1498,11 @@ async function connectUnit() {
document.getElementById('device-bar').style.display = 'flex';
document.getElementById('monitor-panel').style.display = 'flex';
setEventButtonsEnabled();
document.getElementById('load-events-btn').disabled = false;
setDiagButtonsEnabled(true);
document.getElementById('load-btn').disabled = eventList.length === 0;
document.getElementById('save-btn').disabled = eventList.length === 0;
document.getElementById('download-btn').disabled = eventList.length === 0;
document.getElementById('prev-btn').disabled = true;
document.getElementById('next-btn').disabled = eventList.length <= 1;
document.getElementById('cfg-read-btn').disabled = false;
document.getElementById('cfg-write-btn').disabled = false;
document.getElementById('ch-read-btn').disabled = false;
@@ -1588,9 +1510,7 @@ async function connectUnit() {
btn.disabled = false; btn.textContent = 'Reconnect';
setStatus(storageInfo && storageInfo.is_empty
? 'Connected — no events stored.'
: 'Connected. Event list not loaded (Events → Load events).', 'ok');
setStatus(`Connected — ${eventList.length} event${eventList.length !== 1 ? 's' : ''} stored.`, 'ok');
// Fetch monitor status in background (non-blocking)
refreshMonitorStatus().catch(() => {});
@@ -1602,48 +1522,6 @@ async function connectUnit() {
}
}
// ── Shared fetch helper ────────────────────────────────────────────────────────
async function fetchJson(path, opts) {
const sep = path.includes('?') ? '&' : '?';
const r = await fetch(`${api()}${path}${sep}${deviceParams()}`, opts);
const body = await r.json().catch(() => ({}));
if (!r.ok) throw new Error(body.detail || r.statusText);
return body;
}
function setEventButtonsEnabled() {
const n = eventList.length;
document.getElementById('load-btn').disabled = n === 0;
document.getElementById('save-btn').disabled = n === 0;
document.getElementById('download-btn').disabled = n === 0;
document.getElementById('prev-btn').disabled = true;
document.getElementById('next-btn').disabled = n <= 1;
}
// ── Event list (opt-in — this is the slow chain walk) ──────────────────────────
async function loadEventList() {
if (!devHost()) { setStatus('Connect to a device first.', 'error'); return; }
const btn = document.getElementById('load-events-btn');
btn.disabled = true;
setStatus('Walking the event chain — this can take a while…', 'loading');
try {
const evData = await fetchJson('/device/events');
eventList = evData.events || [];
eventsLoaded = true;
// /device/events re-reads compliance; fold it in.
if (evData.device) unitInfo = { ...unitInfo, ...evData.device };
} catch (e) {
setStatus(`Event fetch failed: ${e.message}`, 'error');
btn.disabled = false; return;
}
populateDeviceBar();
populateDeviceTab();
populateEventChips();
setEventButtonsEnabled();
btn.disabled = false;
setStatus(`${eventList.length} event${eventList.length !== 1 ? 's' : ''} stored.`, 'ok');
}
// ── Device bar ─────────────────────────────────────────────────────────────────
function populateDeviceBar() {
qs('di-serial').textContent = unitInfo.serial || '—';
@@ -1652,7 +1530,7 @@ function populateDeviceBar() {
qs('di-sr').textContent = cc.sample_rate ? `${cc.sample_rate} sps` : '—';
qs('di-rt').textContent = cc.record_time != null ? `${cc.record_time.toFixed(1)} s` : '—';
qs('di-trig').textContent = cc.trigger_level_geo != null ? `${cc.trigger_level_geo.toFixed(3)} in/s` : '—';
qs('di-count').textContent = eventsLoaded ? eventList.length : '—';
qs('di-count').textContent = eventList.length;
qs('di-project').textContent = cc.project || '—';
qs('di-client').textContent = cc.client || '—';
qs('di-operator').textContent = cc.operator || '—';
@@ -1782,8 +1660,7 @@ function populateDeviceTab() {
{ label:'DSP', value: unitInfo.dsp_version || '—' },
{ label:'Model', value: unitInfo.model || '—' },
{ label:'Manufacturer', value: unitInfo.manufacturer || '—' },
{ label:'Stored Events', value: eventsLoaded ? eventList.length : 'not loaded' },
{ label:'Storage Used', value: storageUsedLabel() },
{ label:'Stored Events', value: eventList.length },
];
for (const {label, value} of cardData) {
const c = document.createElement('div');
@@ -1830,158 +1707,6 @@ function renderTable(id, rows) {
}
}
// ── Diagnostics ────────────────────────────────────────────────────────────────
// Everything here is a cheap probe (POLL + one read) or a single write. None of
// it walks the event chain. See docs/runbooks/wedged_unit_recovery.md.
function storageUsedLabel() {
if (!storageInfo) return '—';
if (storageInfo.is_empty) return 'empty';
const f = storageInfo.first_key, l = storageInfo.last_key;
return (f && l) ? `${f} → ${l}` : '—';
}
function setDiagButtonsEnabled(on) {
for (const id of ['diag-refresh-btn','diag-stop-btn','diag-ach-btn',
'diag-drip-btn','diag-blind-btn']) {
const el = document.getElementById(id);
if (el) el.disabled = !on;
}
diagCheckEraseConfirm();
}
// Erase is guarded by typing the serial — auth answers "who", not "did you mean it".
function diagCheckEraseConfirm() {
const box = document.getElementById('diag-erase-confirm');
const btn = document.getElementById('diag-erase-btn');
if (!box || !btn) return;
const serial = (unitInfo && unitInfo.serial) || '';
btn.disabled = !serial || box.value.trim().toUpperCase() !== serial.toUpperCase();
}
function diagResult(id, text, cls) {
const el = document.getElementById(id);
if (!el) return;
el.textContent = text;
el.className = 'diag-result' + (cls ? ' ' + cls : '');
}
async function refreshDiagnostics() {
if (!devHost()) return;
const st = document.getElementById('diag-status');
if (st) { st.textContent = 'Reading…'; st.className = 'loading'; }
const [mon, store, idx] = await Promise.all([
fetchJson('/device/monitor/status?force=true').catch(e => ({ _err: e.message })),
fetchJson('/device/events/storage_range').catch(e => ({ _err: e.message })),
fetchJson('/device/events/index').catch(e => ({ _err: e.message })),
]);
if (!store._err) storageInfo = store;
const err = v => `<span style="color:var(--red)">${v}</span>`;
const rows = [];
rows.push(['Monitoring', mon._err ? err(mon._err)
: (mon.is_monitoring ? '<b>MONITORING</b>' : 'idle')]);
if (!mon._err) {
rows.push(['Battery', mon.battery_v != null ? `${mon.battery_v.toFixed(2)} V` : '—']);
if (mon.memory_total_bytes) {
const used = mon.memory_total_bytes - (mon.memory_free_bytes ?? 0);
const pct = (used / mon.memory_total_bytes * 100).toFixed(1);
rows.push(['Memory used', `${used.toLocaleString()} / ${mon.memory_total_bytes.toLocaleString()} bytes (${pct}%)`]);
}
}
rows.push(['Event chain', store._err ? err(store._err) : storageUsedLabel()]);
if (!store._err) rows.push(['Chain empty', store.is_empty ? 'yes' : 'no']);
// SUB 0x08. Known to report 0 on units with years of history — suspected
// field-offset bug in the decode, so show it but do not trust it.
rows.push(['Lifetime events', idx._err ? err(idx._err)
: `${idx.lifetime_count} <span class="hint" style="display:inline">(unreliable — see CHANGELOG)</span>`]);
renderTable('diag-table', rows);
populateDeviceTab();
if (st) { st.textContent = ''; st.className = ''; }
}
async function diagStopMonitoring() {
const btn = document.getElementById('diag-stop-btn');
btn.disabled = true; diagResult('diag-stop-result', 'Sending…');
try {
await fetchJson('/device/monitor/stop', { method: 'POST' });
diagResult('diag-stop-result', 'Stop acknowledged — recording halted.', 'ok');
refreshDiagnostics();
} catch (e) {
diagResult('diag-stop-result', `Failed: ${e.message}`, 'error');
}
btn.disabled = false;
}
async function diagDisableAch() {
const btn = document.getElementById('diag-ach-btn');
btn.disabled = true; diagResult('diag-ach-result', 'Writing call-home config…');
try {
const r = await fetchJson('/device/rescue?erase=false', { method: 'POST' });
const steps = (r.steps || []).map(s => s.step).join(' → ') || 'done';
diagResult('diag-ach-result', `ACH disabled (${steps}). Events untouched.`, 'ok');
} catch (e) {
diagResult('diag-ach-result', `Failed: ${e.message}`, 'error');
}
btn.disabled = false;
}
async function diagEraseEvents() {
const serial = (unitInfo && unitInfo.serial) || 'this unit';
if (!confirm(`Permanently erase ALL events on ${serial}?\n\nThis cannot be undone.`)) return;
const btn = document.getElementById('diag-erase-btn');
btn.disabled = true; diagResult('diag-erase-result', 'Erasing…');
try {
await fetchJson('/device/events/erase', { method: 'POST' });
diagResult('diag-erase-result', 'Events erased — chain reset to 0x01110000.', 'ok');
document.getElementById('diag-erase-confirm').value = '';
eventList = []; eventsLoaded = false;
setEventButtonsEnabled(); populateEventChips();
refreshDiagnostics();
} catch (e) {
diagResult('diag-erase-result', `Failed: ${e.message}`, 'error');
}
diagCheckEraseConfirm();
}
async function diagSlowDrip() {
const btn = document.getElementById('diag-drip-btn');
btn.disabled = true;
diagResult('diag-drip-result', 'Holding a session for 120 s…');
try {
const r = await fetchJson('/device/stop_monitoring_slow_drip?duration_s=120&interval_s=3',
{ method: 'POST' });
const good = (r.bytes_received || 0) > 0;
diagResult('diag-drip-result',
`drips ${r.drips_sent} · held ${r.duration_s}s · bytes back ${r.bytes_received}` +
(r.send_error ? ` · ${r.send_error}` : '') +
(good ? ' → device responded' : ' → no response; the modem may not be bridging'),
good ? 'ok' : 'error');
} catch (e) {
diagResult('diag-drip-result', `Failed: ${e.message}`, 'error');
}
btn.disabled = false;
}
async function diagBlindStop() {
const btn = document.getElementById('diag-blind-btn');
btn.disabled = true; diagResult('diag-blind-result', 'Sending…');
try {
const r = await fetchJson('/device/stop_monitoring_blind', { method: 'POST' });
diagResult('diag-blind-result',
`Sent ${r.bytes_sent ?? '?'} bytes, no response read (fire-and-forget).`, 'ok');
} catch (e) {
diagResult('diag-blind-result', `Failed: ${e.message}`, 'error');
}
btn.disabled = false;
}
// ── Config form ────────────────────────────────────────────────────────────────
function populateConfigFromDeviceInfo() {
if (!unitInfo) return;
+2 -18
View File
@@ -595,19 +595,8 @@ class WaveformStore:
)
# Binary-derived peaks fill in when the .txt didn't supply them.
#
# The old justification for this precedence -- "binary peaks are ~3%
# low vs the .txt" -- was a decoder bug (geo LSB 0.0003 instead of
# 0.000310308) and was fixed 2026-09-10; the binary now agrees with
# Thor's own export per-sample. The .txt still wins when present
# because it is what the operator sees in Thor's report.
#
# ⚠ One case where the .txt is the *less* accurate of the two:
# Thor floors displayed histogram PPV at 0.0050 in/s, so on quiet
# IDFH events the .txt reports 0.0050 while the binary decodes the
# true ~0.0025. 41.4% of prod IDFH sidecars carry a component PPV
# larger than their own vector sum because of it. Left as-is
# deliberately, so stored peaks keep matching Thor's report.
# They're ~3% low vs the device-authoritative .txt values (residual
# codec drift), so .txt always wins when present.
if binary_peaks is not None:
if binary_peaks.transverse_ips and not report_dict.get("tran_ppv"):
report_dict["tran_ppv"] = binary_peaks.transverse_ips
@@ -662,11 +651,6 @@ class WaveformStore:
ev.raw_samples = idf_samples
n_samples = max((len(idf_samples.get(ch, [])) for ch in ("Tran", "Vert", "Long", "MicL")), default=0)
ev.total_samples = ev.total_samples or n_samples
# Sensor self-check traces from the IDFW fixed header (waveform
# events only; {} on histograms / when absent). Carried on the
# bridged Event so the .h5 writer persists them like series-3.
from micromate.sensor_check import decode_idf_sensor_check
ev.sensor_check = decode_idf_sensor_check(idf_bytes) or None
# For IDFH histograms there are no per-sample waveform arrays — the
# device stores one peak ADC count per interval per channel. Synthesise
-222
View File
@@ -1,222 +0,0 @@
"""Fakes of both device clients for sfm.device_access tests.
They return the libraries' real dataclasses, and FakeMicromateClient's setup
is decoded from a real UM20147 read. `fail` is a queue of exceptions; each
call pops one, if any, and raises it.
"""
from __future__ import annotations
import copy
import datetime
from pathlib import Path
from micromate.models import MicromateDeviceInfo, MicromateEventRef, MicromateState
from micromate.setup_block import decode_setup
from minimateplus.models import ComplianceConfig, DeviceInfo, Event, MonitorStatus, PeakValues, Timestamp
SETUP_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-setup" / "um20147_baseline.bin"
THOR_IDF = Path(__file__).parent / "fixtures" / "thor-idf"
class _Base:
def __init__(self, fail=None, open_error=None):
self.fail = list(fail or [])
self.open_error = open_error
self.calls: list[str] = []
self.opened = 0
self.closed = 0
self._open = False
def _step(self, name):
self.calls.append(name)
if self.fail:
raise self.fail.pop(0)
def open(self):
self.opened += 1
if self.open_error is not None:
raise self.open_error
self._open = True
def close(self):
self.closed += 1
self._open = False
def s3_event(index, key_hex, when, *, record_type="Waveform", pvs=0.12, frames=True):
ev = Event(index=index)
ev._waveform_key = bytes.fromhex(key_hex)
ev.timestamp = Timestamp(raw=b"", flag=0x10, year=when.year, unknown_byte=0,
month=when.month, day=when.day, hour=when.hour,
minute=when.minute, second=when.second)
ev.record_type = record_type
ev.peak_values = PeakValues(tran=0.05, vert=0.08, long=0.03, micl=0.0001,
peak_vector_sum=pvs)
if frames:
ev._a5_frames = ["frame"]
return ev
def _iso(ev):
"""minimateplus.client._event_timestamp_iso's format; "" with no timestamp."""
ts = ev.timestamp
if ts is None:
return ""
return datetime.datetime(ts.year, ts.month, ts.day, ts.hour or 0, ts.minute or 0,
ts.second or 0).isoformat()
def default_s3_events():
return [
s3_event(0, "01110000", datetime.datetime(2026, 10, 1, 8, 0, 0)),
s3_event(1, "0111245a", datetime.datetime(2026, 10, 2, 9, 30, 15)),
]
class FakeMiniMateClient(_Base):
def __init__(self, serial="BE18193", *, monitoring=False, compliance="default", events=None, **kw):
super().__init__(**kw)
self.serial = serial
self.monitoring = monitoring
if compliance == "default":
compliance = ComplianceConfig(
recording_mode=0x01, sample_rate=1024, histogram_interval_sec=300,
record_time=3.0, trigger_level_geo=0.5, alarm_level_geo=1.0, geo_range=0,
setup_name="BRIDGE-A", project="Bridge job", client="Acme",
operator="BH", sensor_location="Loc 1", notes=None,
)
self.compliance = compliance
self.events = default_s3_events() if events is None else events
self.download_requests: list = [] # (key4, expected_timestamp) per download
self.last_download = None
def connect(self) -> DeviceInfo:
self._step("connect")
return DeviceInfo(
serial=self.serial, firmware_minor=17, firmware_version="S338.17",
dsp_version="10.72", manufacturer="Instantel", model="MiniMate Plus",
compliance_config=self.compliance,
)
def poll(self) -> None:
self._step("poll")
def get_monitor_status(self) -> MonitorStatus:
self._step("get_monitor_status")
return MonitorStatus(
is_monitoring=self.monitoring, battery_v=6.8,
memory_total=983026, memory_free=900000,
)
def list_event_headers(self):
self._step("list_event_headers")
out = []
for ev in self.events:
h = copy.copy(ev)
h._a5_frames = None
out.append(h)
return out
def download_event_by_key(self, key4, *, expected_timestamp=None):
"""As the real walk: an event whose 0C time is not the expected one comes
back without its 5A."""
self._step("download_event_by_key")
self.download_requests.append((key4, expected_timestamp))
self.last_download = None
for ev in self.events:
if ev._waveform_key == key4:
if expected_timestamp is not None and _iso(ev) != expected_timestamp:
ev = copy.copy(ev)
ev._a5_frames = None
self.last_download = ev
return ev
return None
def s4_ref(index, key_hex, when, record_type, *, pvs=0.2):
"""Fixture-backed: the filename it produces names a real file in thor-idf/."""
ref = MicromateEventRef(index=index, key=bytes.fromhex(key_hex), size=0, serial="UM20147",
record_type=record_type, timestamp=when, peak_vector_sum_ips=pvs,
peaks_ips={"Tran": 0.1, "Vert": 0.15, "Long": 0.05, "Mic": 0.0002})
ref.size = (THOR_IDF / ref.filename).stat().st_size
return ref
def default_s4_refs():
return [
s4_ref(0, "055d4a81", datetime.datetime(2025, 5, 31, 13, 59, 1), "waveform"),
s4_ref(1, "055d4a83", datetime.datetime(2025, 3, 30, 7, 1, 10), "histogram"),
]
class _FakeProtocol:
def __init__(self, owner):
self._owner = owner
def poll(self):
self._owner._step("poll")
class FakeMicromateClient(_Base):
def __init__(self, serial="UM20147", *, monitoring=False, events=5,
unsolicited=b"", event_refs=None, **kw):
super().__init__(**kw)
self.serial = serial
self.monitoring = monitoring
self.events = events
self.unsolicited = unsolicited
self.protocol = _FakeProtocol(self)
self.event_refs = default_s4_refs() if event_refs is None else event_refs
self.cursor = None
self.fetched: list = []
def is_open(self) -> bool:
return self._open
def connect(self) -> MicromateDeviceInfo:
self._step("connect")
return MicromateDeviceInfo(
serial=self.serial, manufacturer="Instantel", model="MM/ISEE/S",
firmware_line="thor", monitoring=self.monitoring, active_setup="test2.MMB",
)
def get_state(self) -> MicromateState:
self._step("get_state")
return MicromateState(
monitoring=self.monitoring,
device_time=datetime.datetime(2026, 10, 20, 18, 7, 58),
battery_volts=3.8, memory_total_bytes=15_000_000, memory_free_bytes=14_799_296,
)
def get_event_count(self) -> int:
self._step("get_event_count")
return self.events
def get_setup(self):
self._step("get_setup")
return decode_setup(SETUP_FIXTURE.read_bytes()[11:])
def read_unsolicited(self) -> bytes:
self._step("read_unsolicited")
data, self.unsolicited = self.unsolicited, b""
return data
def list_events(self, *, with_records=True):
self._step("list_events")
return list(self.event_refs)
def iter_events(self, *, with_records=True):
self._step("iter_events")
for ref in self.event_refs:
self.cursor = ref.index
yield ref
def fetch_event(self, ref, *, verify=True, tolerance=0.01, chunk_size=None):
self._step("fetch_event")
self.fetched.append((ref.key_hex, chunk_size))
return (THOR_IDF / ref.filename).read_bytes(), object()
@staticmethod
def decode_error(ref, result):
return None if ref.record_type == "histogram" else 0.0
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
-50
View File
@@ -1,50 +0,0 @@
"""Structural annotation of a Series-3 Blastware binary (for the seismo_lab
Binary Inspector). The annotator maps byte ranges to labelled spans; anything
the decoder can't account for is a first-class ``unknown`` span, so the whole
file is tiled and the gaps (candidate FFT/spectral data) are visible.
"""
from pathlib import Path
from minimateplus.binary_annotate import annotate_blastware_binary, Span
# A known-good full-3-channel Series-3 waveform binary (the V70 cracking fixture).
FIXTURE = Path(__file__).parent / "fixtures" / "5-11-26" / "M529LL1L.V70"
def _raw() -> bytes:
return FIXTURE.read_bytes()
def test_spans_tile_the_whole_file():
raw = _raw()
spans = annotate_blastware_binary(raw)
assert spans, "expected at least one span"
assert spans[0].start == 0
assert spans[-1].end == len(raw)
for a, b in zip(spans, spans[1:]):
assert a.end == b.start, f"gap/overlap between {a!r} and {b!r}"
for s in spans:
assert s.start < s.end, f"empty/negative span {s!r}"
def test_strt_record_is_located():
raw = _raw()
spans = annotate_blastware_binary(raw)
strt = [s for s in spans if s.kind == "strt"]
assert strt, "expected a STRT region"
assert raw[strt[0].start : strt[0].start + 4] == b"STRT"
def test_geo_sample_records_annotated():
raw = _raw()
spans = annotate_blastware_binary(raw)
chans = {s.label.split()[0] for s in spans if s.kind == "sample"}
# V70 is a full three-geo-channel event.
assert {"Tran", "Vert", "Long"} <= chans, f"expected geo records, got {chans}"
def test_footer_is_last():
raw = _raw()
spans = annotate_blastware_binary(raw)
assert spans[-1].kind == "footer"
assert spans[-1].end - spans[-1].start == 26
-35
View File
@@ -1,35 +0,0 @@
"""USBM/OSMRE compliance curve + scatter logic (sfm.compliance).
Rendering is verified visually against Blastware reports."""
import math
import numpy as np
from sfm.compliance import limit_at, channel_compliance_points
def test_osmre_velocity_segments():
assert abs(limit_at(6.0) - 0.75) < 1e-9 # 3.5–12 Hz flat
assert abs(limit_at(50.0) - 2.00) < 1e-9 # 30–100 Hz flat
def test_displacement_segments():
assert abs(limit_at(2.0) - 2 * math.pi * 2.0 * 0.030) < 1e-9 # low-freq 0.030 in
assert abs(limit_at(20.0) - 2 * math.pi * 20.0 * 0.008) < 1e-9 # rising diagonal 0.008 in
def test_limit_clamps_below_1hz():
assert limit_at(0.1) == limit_at(1.0)
def test_scatter_ceiling_is_ppv_at_dominant_freq():
# ~27 Hz blast-like trace whose energy peaks mid-record (inside full cycles,
# as a real event does): the scatter cloud's ceiling is the trace PPV and the
# top point sits near the dominant frequency.
sps, n = 1024.0, 3328
t = np.arange(n) / sps
env = np.exp(-((t - 1.5) ** 2) / (2 * 0.3 ** 2))
x = 0.9 * env * np.sin(2 * np.pi * 27.0 * t)
f, v = channel_compliance_points(x, sps)
assert len(f) > 20
assert v.max() >= 0.99 * np.abs(x).max()
assert 20.0 < f[int(np.argmax(v))] < 35.0
-244
View File
@@ -1,244 +0,0 @@
"""DeviceAccess: dispatch by serial, sessions, the lock, the reaper -- and the
contract that both series answer in the same shape."""
from __future__ import annotations
import dataclasses
import os
import sys
import threading
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from device_access_fakes import FakeMiniMateClient, FakeMicromateClient # noqa: E402
from sfm.device_access.access import DeviceAccess # noqa: E402
import micromate.protocol as mm_proto # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
BadRequest, CallHomeInProgress, ConnectFailed, UnitBusy, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s4 import RingDetected # noqa: E402
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
class Clock:
def __init__(self, t=1000.0):
self.t = t
def __call__(self):
return self.t
def access(s3=(), s4=(), clock=None, lock_timeout=0.2):
s3q, s4q = list(s3), list(s4)
return DeviceAccess(
s3_client_factory=lambda a: s3q.pop(0),
s4_client_factory=lambda a: s4q.pop(0),
clock=clock or Clock(), lock_timeout=lock_timeout, start_reaper=False,
)
def test_the_serial_prefix_picks_the_adapter():
da = access(s3=[FakeMiniMateClient()], s4=[FakeMicromateClient()])
assert da.identify(ADDR, "be18193").series == 3
assert da.identify(ADDR, " um20147").series == 4
def test_an_unknown_prefix_never_touches_a_unit():
da = access()
with pytest.raises(BadRequest):
da.identify(ADDR, "XX123")
def test_a_micromate_stays_on_the_line_between_requests():
fake = FakeMicromateClient()
da = access(s4=[fake])
da.identify(ADDR, "UM20147")
da.status(ADDR, "UM20147")
da.settings(ADDR, "UM20147")
assert fake.opened == 1 # one call-up, three requests
assert fake.calls[0] == "connect"
def test_a_minimate_reconnects_per_request():
a, b = FakeMiniMateClient(), FakeMiniMateClient()
da = access(s3=[a, b])
da.status(ADDR, "BE18193")
da.status(ADDR, "BE18193")
assert a.closed == 1 and b.closed == 1
def test_a_dropped_line_is_called_up_again_quietly():
first, second = FakeMicromateClient(), FakeMicromateClient()
da = access(s4=[first, second])
da.status(ADDR, "UM20147")
first._open = False # the modem dropped the idle line
st = da.status(ADDR, "UM20147")
assert st.series == 4 and second.opened == 1
def test_a_different_serial_at_a_held_address_is_refused_without_io():
first, second = FakeMicromateClient(), FakeMicromateClient(serial="UM12947")
da = access(s4=[first, second])
da.status(ADDR, "UM20147")
with pytest.raises(WrongUnit, match="hangup"):
da.status(ADDR, "UM12947")
assert first.closed == 0 and second.opened == 0
assert da.held_serial(ADDR) == "UM20147"
def test_a_different_serial_replaces_a_session_that_is_no_longer_open():
first, second = FakeMicromateClient(), FakeMicromateClient(serial="UM12947")
da = access(s4=[first, second])
da.status(ADDR, "UM20147")
first.close()
da.status(ADDR, "UM12947")
assert second.opened == 1
def test_a_busy_unit_answers_423_without_a_second_connection():
fake = FakeMicromateClient()
da = access(s4=[fake], lock_timeout=0.2)
entered, release = threading.Event(), threading.Event()
def slow_request():
with da._locks.hold(ADDR.key): # simulate a request in flight
entered.set()
release.wait(2)
t = threading.Thread(target=slow_request)
t.start()
entered.wait(2)
try:
with pytest.raises(UnitBusy):
da.status(ADDR, "UM20147")
assert fake.opened == 0 # no second connection was opened
finally:
release.set()
t.join()
def test_hang_up_closes_a_held_line():
fake = FakeMicromateClient()
da = access(s4=[fake])
da.status(ADDR, "UM20147")
assert da.hang_up(ADDR) is True
assert fake.closed == 1
assert da.hang_up(ADDR) is False # nothing left to hang up
def test_a_peer_dropped_line_that_still_reads_open_is_retried_once():
first, second = FakeMicromateClient(), FakeMicromateClient()
da = access(s4=[first, second])
da.status(ADDR, "UM20147")
first.fail = [mm_proto.TimeoutError("quiet")] # _open untouched: looks open
st = da.status(ADDR, "UM20147")
assert st.series == 4 and first.closed == 1 and second.opened == 1
def test_a_failed_fresh_call_up_is_not_retried():
da = access(s4=[FakeMicromateClient(open_error=ConnectionRefusedError("no"))])
with pytest.raises(ConnectFailed):
da.status(ADDR, "UM20147") # a 2nd attempt would pop an empty queue
def test_a_ring_on_a_held_line_is_not_retried():
first, second = FakeMicromateClient(), FakeMicromateClient()
da = access(s4=[first, second])
da.status(ADDR, "UM20147")
first.fail = [RingDetected("RADIO RING")]
with pytest.raises(CallHomeInProgress):
da.status(ADDR, "UM20147")
assert second.opened == 0
def test_series3_beside_a_held_series4_line_is_refused_without_io():
micro, mini = FakeMicromateClient(), FakeMiniMateClient()
da = access(s3=[mini], s4=[micro])
da.status(ADDR, "UM20147")
with pytest.raises(WrongUnit):
da.status(ADDR, "BE18193")
assert mini.opened == 0 and micro.closed == 0 and micro.is_open()
# ── the reaper ────────────────────────────────────────────────────────────────
def test_tick_listens_then_keeps_alive_then_hangs_up_when_idle():
clock = Clock(1000.0)
fake = FakeMicromateClient()
da = access(s4=[fake], clock=clock)
da.status(ADDR, "UM20147")
fake.calls.clear()
clock.t = 1030.0
da.tick() # quiet: listen only
assert fake.calls == ["read_unsolicited"]
clock.t = 1061.0
da.tick() # 60 s since traffic: keep-alive
assert fake.calls[-1] == "poll"
clock.t = 1301.0
da.tick() # 300 s since last USE: hang up
assert fake.closed == 1
assert da.hang_up(ADDR) is False
def test_tick_releases_the_line_on_a_ring_while_idle():
clock = Clock(1000.0)
fake = FakeMicromateClient()
da = access(s4=[fake], clock=clock)
da.status(ADDR, "UM20147")
fake.fail = [RingDetected("RADIO RING")]
clock.t = 1010.0
da.tick()
assert fake.closed == 1
def test_tick_skips_a_unit_that_is_busy():
clock = Clock(1000.0)
fake = FakeMicromateClient()
da = access(s4=[fake], clock=clock)
da.status(ADDR, "UM20147")
fake.calls.clear()
clock.t = 1400.0
with da._locks.hold(ADDR.key):
da.tick() # must not block or hang up mid-request
assert fake.calls == [] and fake.closed == 0
def test_a_ring_mid_request_is_a_clear_error():
fake = FakeMicromateClient()
da = access(s4=[fake])
da.status(ADDR, "UM20147")
fake.fail = [RingDetected("RADIO RING")]
with pytest.raises(CallHomeInProgress):
da.status(ADDR, "UM20147")
# ── the contract: both series answer in the same shape ────────────────────────
@pytest.mark.parametrize("op", ["identify", "status", "settings"])
def test_both_series_return_the_same_model_with_the_same_fields(op):
da = access(s3=[FakeMiniMateClient()], s4=[FakeMicromateClient()])
s3 = getattr(da, op)(ADDR, "BE18193")
s4 = getattr(da, op)(ADDR, "UM20147")
assert type(s3) is type(s4)
assert [f.name for f in dataclasses.fields(s3)] == [f.name for f in dataclasses.fields(s4)]
assert (s3.series, s4.series) == (3, 4)
for name in (f.name for f in dataclasses.fields(s3)):
a, b = getattr(s3, name), getattr(s4, name)
if a is not None and b is not None and name != "detail":
assert type(a) is type(b) or {type(a), type(b)} <= {int, float}, name
def test_held_serial_reports_an_open_line_only():
fake = FakeMicromateClient()
da = access(s4=[fake])
assert da.held_serial(ADDR) is None
da.status(ADDR, "UM20147")
assert da.held_serial(ADDR) == "UM20147"
da.hang_up(ADDR)
assert da.held_serial(ADDR) is None
-138
View File
@@ -1,138 +0,0 @@
"""Core types of sfm.device_access: errors, series selection, models."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import micromate.protocol as mm_proto # noqa: E402
import minimateplus.protocol as mmp_proto # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
BadRequest, ConnectFailed, DeviceError, MalformedReply, NoAnswer, translate,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.series import normalise_serial, series_for_serial # noqa: E402
# ── series ────────────────────────────────────────────────────────────────────
@pytest.mark.parametrize(
"serial, series",
[("UM20147", 4), ("BE18193", 3), ("BA4521", 3), (" um20147 ", 4), ("be11529", 3)],
)
def test_the_prefix_picks_the_series(serial, series):
assert series_for_serial(serial) == series
def test_serials_are_normalised():
assert normalise_serial(" um20147\n") == "UM20147"
@pytest.mark.parametrize("serial", ["", "UM", "XX12345", "12345", "MP1234"])
def test_an_unknown_or_bare_prefix_is_a_bad_request(serial):
with pytest.raises(BadRequest, match="UM"):
series_for_serial(serial)
# ── errors ────────────────────────────────────────────────────────────────────
@pytest.mark.parametrize(
"exc, connecting, cls, status",
[
(mm_proto.TimeoutError("no frame"), False, NoAnswer, 504),
(mmp_proto.TimeoutError("no frame"), False, NoAnswer, 504),
(mm_proto.ChecksumError("bad"), False, MalformedReply, 502),
(mmp_proto.ProtocolError("bad"), False, MalformedReply, 502),
(ConnectionRefusedError("refused"), True, ConnectFailed, 503),
(OSError("reset"), False, ConnectFailed, 503),
],
)
def test_library_exceptions_translate_to_typed_errors(exc, connecting, cls, status):
out = translate(exc, connecting=connecting)
assert isinstance(out, cls)
assert out.http_status == status
def test_connect_and_mid_session_failures_read_differently():
assert "could not connect" in str(translate(OSError("x"), connecting=True))
assert "connection lost" in str(translate(OSError("x"), connecting=False))
def test_a_device_error_passes_through_unchanged():
e = NoAnswer("quiet")
assert translate(e, connecting=False) is e
def test_anything_else_becomes_a_plain_device_error():
out = translate(ValueError("boom"), connecting=False)
assert type(out) is DeviceError and out.http_status == 500
# ── models ────────────────────────────────────────────────────────────────────
def test_an_address_needs_a_host_or_a_port():
with pytest.raises(BadRequest):
UnitAddress(host=None, tcp_port=None, port=None, baud=None)
def test_the_lock_key_names_the_physical_link():
assert UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None).key == "tcp:10.0.0.5:9034"
assert UnitAddress(host=None, tcp_port=None, port="/dev/ttyACM0", baud=115200).key == "serial:/dev/ttyACM0"
# ── per-unit lock ─────────────────────────────────────────────────────────────
import threading # noqa: E402
from sfm.device_access.errors import UnitBusy # noqa: E402
from sfm.device_access.locks import UnitLocks # noqa: E402
def test_a_second_request_for_a_busy_unit_gets_unit_busy():
locks = UnitLocks(timeout=0.2)
entered = threading.Event()
release = threading.Event()
def holder():
with locks.hold("tcp:10.0.0.5:9034"):
entered.set()
release.wait(2)
t = threading.Thread(target=holder)
t.start()
entered.wait(2)
try:
with pytest.raises(UnitBusy, match="busy"):
with locks.hold("tcp:10.0.0.5:9034"):
pass
finally:
release.set()
t.join()
def test_different_units_do_not_block_each_other():
locks = UnitLocks(timeout=0.2)
with locks.hold("tcp:10.0.0.5:9034"):
with locks.hold("tcp:10.0.0.6:9034"):
pass
def test_try_hold_never_waits():
locks = UnitLocks(timeout=5)
with locks.hold("k"):
with locks.try_hold("k") as got:
assert got is False
with locks.try_hold("k") as got:
assert got is True
def test_the_lock_is_released_after_an_exception():
locks = UnitLocks(timeout=0.2)
with pytest.raises(RuntimeError):
with locks.hold("k"):
raise RuntimeError("boom")
with locks.hold("k"):
pass
-106
View File
@@ -1,106 +0,0 @@
"""Events through the one door: same shape both series, the held line, ring safety."""
from __future__ import annotations
import dataclasses
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from device_access_fakes import FakeMicromateClient, FakeMiniMateClient # noqa: E402
from sfm.device_access.access import DeviceAccess # noqa: E402
from sfm.device_access.errors import BadRequest, CallHomeInProgress # noqa: E402
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s4 import RingDetected # noqa: E402
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
def access(s3=(), s4=()):
s3q, s4q = list(s3), list(s4)
return DeviceAccess(s3_client_factory=lambda a, **kw: s3q.pop(0),
s4_client_factory=lambda a, **kw: s4q.pop(0), start_reaper=False)
def test_both_series_list_events_in_the_same_shape():
s3 = access(s3=[FakeMiniMateClient()]).list_events(ADDR, "BE18193")
s4 = access(s4=[FakeMicromateClient()]).list_events(ADDR, "UM20147")
f3 = [set(dataclasses.asdict(e)) for e in s3.events]
f4 = [set(dataclasses.asdict(e)) for e in s4.events]
assert all(f == f3[0] for f in f3 + f4)
def test_no_shared_field_is_empty_for_either_series():
# A field one series cannot fill belongs under `detail`, not at the top level.
# Except Series 3's record_type: its 0C cannot tell a histogram yet, and null beats a wrong type.
allowed = {3: {"record_type"}, 4: set()}
for out in (access(s3=[FakeMiniMateClient()]).list_events(ADDR, "BE18193"),
access(s4=[FakeMicromateClient()]).list_events(ADDR, "UM20147")):
for e in out.events:
empty = {k for k, v in dataclasses.asdict(e).items() if v is None}
assert empty == allowed[out.series], (out.series, empty)
def test_a_micromate_list_and_download_share_one_held_line():
fake = FakeMicromateClient()
da = access(s4=[fake])
listed = da.list_events(ADDR, "UM20147")
dl = da.download_event(ADDR, "UM20147", listed.events[0].event_id)
assert fake.opened == 1 and dl.idf_bytes
assert da.held_serial(ADDR) == "UM20147"
def test_an_id_from_another_unit_is_refused_before_any_io():
fake = FakeMicromateClient()
with pytest.raises(BadRequest):
access(s4=[fake]).download_event(ADDR, "UM20147", "UM12947:055d4a81:20250531135901")
assert fake.opened == 0
def test_a_minimate_download_goes_through_the_series3_adapter():
dl = access(s3=[FakeMiniMateClient()]).download_event(ADDR, "BE18193", "BE18193:01110000:-")
assert dl.series == 3 and dl.a5_frames == ["frame"]
def test_a_ring_mid_download_releases_the_line_and_downloads_nothing():
fake = FakeMicromateClient()
def ring(*a, **kw):
raise RingDetected("RADIO RING")
fake.fetch_event = ring
da = access(s4=[fake])
with pytest.raises(CallHomeInProgress):
da.download_event(ADDR, "UM20147", "UM20147:055d4a81:20250531135901")
assert fake.closed == 1 and da.held_serial(ADDR) is None
def test_a_library_error_mid_download_hangs_up():
# Only a DeviceError verdict keeps the line; anything the library raises means
# the link is suspect. A fresh DeviceAccess, so the held-line retry cannot apply.
from micromate.protocol import TimeoutError as MicromateTimeout
from sfm.device_access.errors import NoAnswer
fake = FakeMicromateClient()
def quiet(*a, **kw):
raise MicromateTimeout("quiet")
fake.fetch_event = quiet
da = access(s4=[fake])
with pytest.raises(NoAnswer):
da.download_event(ADDR, "UM20147", "UM20147:055d4a81:20250531135901")
assert fake.closed == 1 and da.held_serial(ADDR) is None
def test_a_stale_or_missing_event_keeps_the_line():
# The operation's own verdict (404/409) says nothing is wrong with the link;
# hanging up would cost a call-up for no reason.
from sfm.device_access.errors import EventNotFound, StaleEvent
fake = FakeMicromateClient()
da = access(s4=[fake])
with pytest.raises(StaleEvent):
da.download_event(ADDR, "UM20147", "UM20147:055d4a81:20240101000000")
with pytest.raises(EventNotFound):
da.download_event(ADDR, "UM20147", "UM20147:deadbeef:-")
assert fake.opened == 1 and fake.closed == 0
assert da.held_serial(ADDR) == "UM20147"
-53
View File
@@ -1,53 +0,0 @@
"""Event identity: serial + key + timestamp, so a stale or foreign id fails loudly."""
from __future__ import annotations
import datetime
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from sfm.device_access.errors import BadRequest, EventNotFound, StaleEvent # noqa: E402
from sfm.device_access.events import ( # noqa: E402
iso_of, make_event_id, parse_event_id, stamp_of,
)
KEY = bytes.fromhex("055d4a81")
WHEN = datetime.datetime(2025, 5, 31, 13, 59, 1)
def test_an_event_id_round_trips():
eid = make_event_id("um20147", KEY, stamp_of(WHEN))
assert eid == "UM20147:055d4a81:20250531135901"
assert parse_event_id(eid, "UM20147") == (KEY, "20250531135901")
def test_an_unknown_timestamp_round_trips_as_none():
eid = make_event_id("BE18193", bytes.fromhex("01110000"), None)
assert eid == "BE18193:01110000:-"
assert parse_event_id(eid, "be18193") == (bytes.fromhex("01110000"), None)
def test_an_id_from_another_unit_is_refused():
# UM12947 and UM20147 both have an event 055d4a81
with pytest.raises(BadRequest, match="UM12947"):
parse_event_id("UM12947:055d4a81:20250531135901", "UM20147")
@pytest.mark.parametrize("bad", ["", "UM20147", "UM20147:055d4a81",
"UM20147:zz:20250531135901", "UM20147:055d4a:20250531135901",
"UM20147:055d4a81:2025"])
def test_a_malformed_id_is_refused(bad):
with pytest.raises(BadRequest):
parse_event_id(bad, "UM20147")
def test_iso_and_stamp_of_none_are_none():
assert iso_of(None) is None and stamp_of(None) is None
assert iso_of(WHEN) == "2025-05-31T13:59:01"
def test_the_new_errors_have_their_statuses():
assert (EventNotFound.http_status, StaleEvent.http_status) == (404, 409)
-87
View File
@@ -1,87 +0,0 @@
"""The Series-3 adapter: connect-per-request, mapped into the shared models."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import minimateplus.protocol as mmp_proto # noqa: E402
from device_access_fakes import FakeMiniMateClient # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
ConnectFailed, MalformedReply, NoAnswer, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s3 import Series3Adapter # noqa: E402
TCP = UnitAddress(host="10.0.0.5", tcp_port=12345, port=None, baud=None)
SERIAL_LINK = UnitAddress(host=None, tcp_port=None, port="/dev/ttyUSB0", baud=None)
def adapter(*clients):
queue = list(clients)
return Series3Adapter(client_factory=lambda address: queue.pop(0))
def test_identify_maps_device_info():
fake = FakeMiniMateClient()
info = adapter(fake).identify(TCP, "BE18193")
assert (info.serial, info.series, info.model, info.firmware) == ("BE18193", 3, "MiniMate Plus", "S338.17")
assert info.active_setup == "BRIDGE-A"
assert info.monitoring is None # connect() does not read it on Series 3
assert fake.closed == 1
def test_a_different_unit_answering_is_refused():
fake = FakeMiniMateClient(serial="BE11529")
with pytest.raises(WrongUnit, match="BE18193.*BE11529"):
adapter(fake).identify(TCP, "BE18193")
assert fake.closed == 1
def test_status_maps_monitor_status():
fake = FakeMiniMateClient(monitoring=True)
st = adapter(fake).status(TCP, "BE18193")
assert (st.series, st.monitoring, st.battery_volts) == (3, True, 6.8)
assert (st.memory_total_bytes, st.memory_free_bytes) == (983026, 900000)
assert st.event_count is None and st.device_time is None
assert st.detail == {"serial_verified": False}
assert fake.calls == ["poll", "get_monitor_status"]
def test_settings_maps_the_compliance_config():
s = adapter(FakeMiniMateClient()).settings(TCP, "BE18193")
assert s.record_mode == "Continuous"
assert (s.sample_rate, s.record_time_s, s.histogram_interval_s) == (1024, 3.0, 300)
assert s.geo_trigger_ips == 0.5
assert s.setup_name == "BRIDGE-A"
assert s.notes == {"Project": "Bridge job", "Client": "Acme", "User Name": "BH", "Seis Loc": "Loc 1"}
assert s.detail["record_mode_code"] == 0x01
def test_settings_without_a_compliance_read_is_a_malformed_reply_and_not_retried():
# One fake only: a retry would ask the factory for a second and fail.
with pytest.raises(MalformedReply, match="settings"):
adapter(FakeMiniMateClient(compliance=None)).settings(TCP, "BE18193")
def test_a_cold_unit_over_tcp_gets_one_retry():
first = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("cold")])
second = FakeMiniMateClient()
info = adapter(first, second).identify(TCP, "BE18193")
assert info.serial == "BE18193"
assert first.closed == 1 and second.closed == 1
def test_a_serial_link_is_not_retried():
fake = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("quiet")])
with pytest.raises(NoAnswer):
adapter(fake).identify(SERIAL_LINK, "BE18193")
def test_a_failed_connect_is_connect_failed_and_not_retried():
fake = FakeMiniMateClient(open_error=ConnectionRefusedError("refused"))
with pytest.raises(ConnectFailed, match="could not connect"):
adapter(fake).identify(TCP, "BE18193")
-131
View File
@@ -1,131 +0,0 @@
"""Series-3 events: listed from headers, one downloaded, mapped into the shared shape."""
from __future__ import annotations
import datetime
import os
import struct
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from device_access_fakes import FakeMiniMateClient, s3_event # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
EventNotFound, MalformedReply, StaleEvent, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s3 import Series3Adapter # noqa: E402
TCP = UnitAddress(host="10.0.0.5", tcp_port=12345, port=None, baud=None)
FIRST = bytes.fromhex("01110000")
def adapter(*clients):
queue = list(clients)
seen = []
def factory(address, **kw):
seen.append(kw)
return queue.pop(0)
a = Series3Adapter(client_factory=factory)
a.seen = seen
return a
def test_listing_maps_each_header_into_the_shared_shape():
out = adapter(FakeMiniMateClient()).list_events(TCP, "BE18193")
assert (out.serial, out.series, len(out.events)) == ("BE18193", 3, 2)
e = out.events[1]
assert e.event_id == "BE18193:0111245a:20261002093015"
assert (e.index, e.timestamp) == (1, "2026-10-02T09:30:15")
# The 0C record does not say waveform or histogram (every layout reads "Waveform").
assert e.record_type is None and "not decoded yet" in e.detail["record_type_note"]
assert e.peaks_ips == {"tran": 0.05, "vert": 0.08, "long": 0.03}
assert e.peak_vector_sum_ips == 0.12 and e.detail["mic_psi"] == 0.0001
assert e.filename and e.filename.startswith("T193")
def test_listing_uses_the_header_walk_and_the_default_timeout():
# A header walk is small replies only; a lost one should cost 10 s, not 120 s.
fake = FakeMiniMateClient()
a = adapter(fake)
a.list_events(TCP, "BE18193")
assert "list_event_headers" in fake.calls and "download_event_by_key" not in fake.calls
assert a.seen == [{}]
assert fake.closed == 1
def test_downloading_uses_the_long_timeout():
a = adapter(FakeMiniMateClient())
a.download_event(TCP, "BE18193", FIRST, None)
assert a.seen == [{"timeout": 120.0}]
def test_listing_refuses_a_different_unit():
with pytest.raises(WrongUnit):
adapter(FakeMiniMateClient(serial="BE11529")).list_events(TCP, "BE18193")
def test_download_returns_the_event_its_frames_and_the_settings():
fake = FakeMiniMateClient()
dl = adapter(fake).download_event(TCP, "BE18193", FIRST, "20261001080000")
assert (dl.series, dl.event_id, dl.verified) == (3, "BE18193:01110000:20261001080000", None)
assert dl.event is fake.events[0] and dl.a5_frames == ["frame"]
assert dl.compliance is fake.compliance and dl.filename.startswith("T193")
assert dl.timestamp == datetime.datetime(2026, 10, 1, 8, 0, 0)
def test_download_refuses_a_different_unit_before_downloading():
fake = FakeMiniMateClient(serial="BE11529")
with pytest.raises(WrongUnit):
adapter(fake).download_event(TCP, "BE18193", FIRST, None)
assert "download_event_by_key" not in fake.calls
def test_a_key_that_is_not_stored_is_404():
with pytest.raises(EventNotFound):
adapter(FakeMiniMateClient()).download_event(TCP, "BE18193", bytes.fromhex("0111ffff"), None)
def test_a_stale_id_is_refused_rather_than_downloading_another_event():
fake = FakeMiniMateClient()
with pytest.raises(StaleEvent, match="20261001080000"):
adapter(fake).download_event(TCP, "BE18193", FIRST, "20250101000000")
# The walk was told what to expect, so it compared after 0C and sent no 5A.
assert fake.download_requests == [(FIRST, "2025-01-01T00:00:00")]
assert fake.last_download is not None and fake.last_download._a5_frames is None
def test_an_id_without_a_timestamp_skips_the_check():
fake = FakeMiniMateClient()
dl = adapter(fake).download_event(TCP, "BE18193", FIRST, None)
assert dl.event_id == "BE18193:01110000:20261001080000"
assert fake.download_requests == [(FIRST, None)]
def test_a_target_whose_record_could_not_be_read_is_not_called_stale():
# A lost 0C reply leaves no timestamp to compare: that is a bad reply, not an erase.
ev = s3_event(0, "01110000", datetime.datetime(2026, 10, 1, 8, 0, 0))
ev.timestamp = None
fake = FakeMiniMateClient(events=[ev])
with pytest.raises(MalformedReply, match="0C"):
adapter(fake).download_event(TCP, "BE18193", FIRST, "20261001080000")
assert fake.last_download._a5_frames is None
def test_a_failed_5a_is_a_clear_error():
fake = FakeMiniMateClient(events=[s3_event(0, "01110000",
datetime.datetime(2026, 10, 1, 8, 0, 0), frames=False)])
with pytest.raises(MalformedReply, match="5A"):
adapter(fake).download_event(TCP, "BE18193", FIRST, None)
def test_the_64k_page_bug_is_named_not_a_bare_500():
fake = FakeMiniMateClient()
def boom(key4, **kw):
raise struct.error("argument out of range")
fake.download_event_by_key = boom
with pytest.raises(MalformedReply, match="64 KB"):
adapter(fake).download_event(TCP, "BE18193", FIRST, None)
-322
View File
@@ -1,322 +0,0 @@
"""Series-4 sessions: one call-up, then stay on the line; ring safety."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import micromate.protocol as mm_proto # noqa: E402
from device_access_fakes import FakeMicromateClient # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
CallHomeInProgress, ConnectFailed, NoAnswer, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s4 import ( # noqa: E402
RingDetected, RingWatchTransport, Series4Session,
)
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
class ScriptedInner:
"""A minimal real-interface transport: is_connected is a PROPERTY."""
def __init__(self, chunks):
self.chunks = list(chunks)
self.written = []
self._c = False
def connect(self):
self._c = True
def disconnect(self):
self._c = False
@property
def is_connected(self):
return self._c
def write(self, data):
self.written.append(data)
def read(self, n):
return self.chunks.pop(0) if self.chunks else b""
class Clock:
def __init__(self, t=1000.0):
self.t = t
def __call__(self):
return self.t
def session(*clients, clock=None):
queue = list(clients)
return Series4Session(ADDR, "UM20147", lambda address: queue.pop(0), clock=clock or Clock())
# ── RingWatchTransport ────────────────────────────────────────────────────────
def test_ordinary_bytes_pass_through():
t = RingWatchTransport(ScriptedInner([b"\x02abc\x03"]))
assert t.read(4096) == b"\x02abc\x03"
def test_a_ring_raises():
t = RingWatchTransport(ScriptedInner([b"\r\nRADIO RING\r\n"]))
with pytest.raises(RingDetected):
t.read(4096)
def test_a_ring_split_across_reads_still_raises():
t = RingWatchTransport(ScriptedInner([b"\r\nRADIO R", b"ING\r\n"]))
assert t.read(4096) == b"\r\nRADIO R"
with pytest.raises(RingDetected):
t.read(4096)
def _real_frame(payload_data: bytes, sub: int = 0xA4) -> bytes:
from micromate.framing import ETX, STX, checksum, stuff
payload = bytes([0x00, 0xC5, sub, 0x00, 0x00]) + payload_data
return bytes([STX]) + stuff(payload + bytes([checksum(payload)])) + bytes([ETX])
def test_a_ring_inside_a_frame_is_data_not_a_call_home():
# The 0x2C call-home config block's dial string is literally "RADIO RING".
wire = _real_frame(b"\x00" * 6 + b"RADIO RING" + b"\x00" * 4)
t = RingWatchTransport(ScriptedInner([wire]))
assert t.read(4096) == wire
def test_a_ring_inside_a_frame_split_across_reads_is_still_data():
wire = _real_frame(b"xxRADIO RINGyy")
cut = wire.index(b"RADIO R") + 7
t = RingWatchTransport(ScriptedInner([wire[:cut], wire[cut:]]))
assert t.read(4096) == wire[:cut]
assert t.read(4096) == wire[cut:]
def test_a_ring_between_frames_still_raises():
t = RingWatchTransport(ScriptedInner([_real_frame(b"abc") + b"\r\nRADIO RING\r\n"]))
with pytest.raises(RingDetected):
t.read(4096)
def test_a_ring_split_across_reads_after_a_frame_still_raises():
t = RingWatchTransport(ScriptedInner([_real_frame(b"abc") + b"\r\nRADIO R", b"ING\r\n"]))
t.read(4096)
with pytest.raises(RingDetected):
t.read(4096)
def test_a_ring_arriving_right_after_a_frame_ends_still_raises():
t = RingWatchTransport(ScriptedInner([_real_frame(b"abc"), b"RADIO RING"]))
t.read(4096)
with pytest.raises(RingDetected):
t.read(4096)
def test_an_escaped_etx_inside_a_frame_does_not_end_it():
# DLE ETX inside the payload is literal data; the ring after it is still inside.
wire = b"\x02" + b"ab\x10\x03RADIO RINGcd" + b"\x03"
t = RingWatchTransport(ScriptedInner([wire]))
assert t.read(4096) == wire
def test_a_ring_that_follows_a_frame_with_an_escaped_etx_still_raises():
wire = b"\x02" + b"ab\x10\x03cd" + b"\x03" + b"RADIO RING"
t = RingWatchTransport(ScriptedInner([wire]))
with pytest.raises(RingDetected):
t.read(4096)
def _real_chain_client(chunks):
from micromate.client import MicromateClient
inner = ScriptedInner(chunks)
return MicromateClient(RingWatchTransport(inner), recv_timeout=0.5), inner
def test_real_chain_a_response_carrying_a_ring_in_its_payload_succeeds():
client, _ = _real_chain_client([_real_frame(b"\x30" + b"\x00" * 8 + b"RADIO RING")])
client.open()
frame = client.protocol.poll()
assert b"RADIO RING" in frame.data
def test_real_chain_an_unsolicited_ring_before_the_response_hangs_up():
from types import SimpleNamespace
client, inner = _real_chain_client([b"\r\nRADIO RING\r\n", _real_frame(b"\x30" + b"\x00" * 8)])
# Only the identity read is stubbed; open/close/protocol/transport are the real chain.
client.connect = lambda: SimpleNamespace(serial="UM20147")
s = Series4Session(ADDR, "UM20147", lambda address: client, clock=Clock())
with pytest.raises(CallHomeInProgress):
s.run(lambda c: c.protocol.poll())
assert not s.is_open and not inner.is_connected
def test_the_wrapper_keeps_is_connected_a_property():
inner = ScriptedInner([])
t = RingWatchTransport(inner)
t.connect()
assert t.is_connected is True
# ── call-up ───────────────────────────────────────────────────────────────────
def test_call_up_verifies_the_serial_once():
fake = FakeMicromateClient()
s = session(fake)
s.run(lambda c: c.get_state())
s.run(lambda c: c.get_event_count())
assert fake.calls == ["connect", "get_state", "get_event_count"]
assert fake.opened == 1
def test_a_different_unit_answering_is_refused_and_closed():
fake = FakeMicromateClient(serial="UM12947")
s = session(fake)
with pytest.raises(WrongUnit, match="UM20147.*UM12947"):
s.run(lambda c: c.get_state())
assert fake.closed == 1 and not s.is_open
assert fake.calls == ["connect"] # nothing after the identity check
def test_a_failed_connect_is_connect_failed():
s = session(FakeMicromateClient(open_error=ConnectionRefusedError("no")))
with pytest.raises(ConnectFailed, match="could not connect"):
s.run(lambda c: c.get_state())
# ── ring safety ───────────────────────────────────────────────────────────────
def test_a_ring_during_a_request_releases_the_line():
fake = FakeMicromateClient()
s = session(fake)
s.call_up()
fake.fail = [RingDetected("RADIO RING")]
with pytest.raises(CallHomeInProgress, match="calling home"):
s.run(lambda c: c.get_state())
assert not s.is_open and fake.closed == 1
def test_listen_while_idle_releases_the_line_on_a_ring_and_sends_nothing():
fake = FakeMicromateClient()
s = session(fake)
s.call_up()
fake.fail = [RingDetected("RADIO RING")]
with pytest.raises(CallHomeInProgress):
s.listen()
assert not s.is_open
assert fake.calls == ["connect", "read_unsolicited"]
def test_the_next_request_after_a_ring_calls_up_fresh():
first, second = FakeMicromateClient(), FakeMicromateClient()
s = session(first, second)
s.call_up()
first.fail = [RingDetected("RADIO RING")]
with pytest.raises(CallHomeInProgress):
s.run(lambda c: c.get_state())
s.run(lambda c: c.get_state())
assert second.calls == ["connect", "get_state"]
# ── what counts as use ────────────────────────────────────────────────────────
def test_keepalive_and_listen_do_not_count_as_use():
clock = Clock(1000.0)
fake = FakeMicromateClient()
s = session(fake, clock=clock)
s.call_up()
clock.t = 1060.0
s.keepalive()
clock.t = 1065.0
s.listen()
assert s.last_used == 1000.0
assert s.last_traffic == 1060.0
assert fake.calls == ["connect", "poll", "read_unsolicited"]
def test_a_request_counts_as_use():
clock = Clock(1000.0)
s = session(FakeMicromateClient(), clock=clock)
s.call_up()
clock.t = 1100.0
s.run(lambda c: c.get_state())
assert s.last_used == 1100.0 and s.last_traffic == 1100.0
def test_a_failure_mid_request_hangs_up():
fake = FakeMicromateClient()
s = session(fake)
s.call_up()
fake.fail = [mm_proto.TimeoutError("quiet")]
with pytest.raises(NoAnswer):
s.run(lambda c: c.get_state())
assert not s.is_open
# ── operations ────────────────────────────────────────────────────────────────
from sfm.device_access.s4 import s4_identify, s4_settings, s4_status # noqa: E402
def test_s4_identify():
info = s4_identify(FakeMicromateClient(monitoring=True), "UM20147")
assert (info.serial, info.series, info.model, info.monitoring) == ("UM20147", 4, "MM/ISEE/S", True)
assert info.active_setup == "test2.MMB"
assert info.firmware is None and info.detail["firmware_line"] == "thor"
def test_s4_status_includes_the_cheap_event_count():
st = s4_status(FakeMicromateClient(events=5), "UM20147")
assert (st.series, st.monitoring, st.battery_volts, st.event_count) == (4, False, 3.8, 5)
assert (st.memory_total_bytes, st.memory_free_bytes) == (15_000_000, 14_799_296)
assert st.device_time == "2026-10-20T18:07:58"
def test_s4_settings_maps_the_decoded_setup():
s = s4_settings(FakeMicromateClient(), "UM20147")
assert (s.series, s.setup_name, s.record_mode) == (4, "test2.MMB", "Histogram Combo")
assert (s.sample_rate, s.record_time_s, s.histogram_interval_s) == (1024, 10.0, 2)
assert s.geo_trigger_ips == pytest.approx(0.5, abs=1e-6)
assert list(s.notes) == ["Location", "Client", "Company", "General Notes"]
assert s.detail["pretrigger_s"] == 1.0
assert s.detail["mic_type"] == "linear"
assert s.detail["mic_trigger_db"] == pytest.approx(131.0, abs=0.01)
assert s.detail["geo_trigger_ips_per_channel"] == pytest.approx([0.5, 0.5, 0.5], abs=1e-6)
def test_a_new_request_clears_frame_state_left_by_a_stray_stx():
# A stray STX on an idle line would otherwise hide the ring that answers the
# next request. MicromateProtocol resets its own parser at every request too.
t = RingWatchTransport(ScriptedInner([b"\x02stray", b"\r\nRADIO RING\r\n"]))
t.connect()
t.read(64)
t.write(b"x")
with pytest.raises(RingDetected):
t.read(64)
def test_is_open_survives_a_hang_up_between_its_two_reads():
# held_serial() calls is_open without the unit lock; a concurrent hang-up can
# clear _client between the None check and the method call.
class Racy(Series4Session):
_reads = 0
@property
def _client(self):
Racy._reads += 1
return object.__new__(type("C", (), {"is_open": lambda s: True})) if Racy._reads == 1 else None
@_client.setter
def _client(self, value):
pass
s = Racy(ADDR, "UM20147", client_factory=lambda a: None)
assert s.is_open in (True, False)
-71
View File
@@ -1,71 +0,0 @@
"""Series-4 events: the chain walk mapped into the shared shape; download at the cursor."""
from __future__ import annotations
import datetime
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from device_access_fakes import THOR_IDF, FakeMicromateClient # noqa: E402
from micromate.protocol import THOR_CHUNK_SIZE # noqa: E402
from sfm.device_access.errors import EventNotFound, StaleEvent # noqa: E402
from sfm.device_access.s4 import s4_download_event, s4_list_events # noqa: E402
W_KEY, H_KEY = bytes.fromhex("055d4a81"), bytes.fromhex("055d4a83")
def test_listing_maps_each_ref_into_the_shared_shape():
out = s4_list_events(FakeMicromateClient(), "UM20147")
assert (out.serial, out.series, len(out.events)) == ("UM20147", 4, 2)
e = out.events[0]
assert e.event_id == "UM20147:055d4a81:20250531135901"
assert (e.index, e.timestamp, e.record_type) == (0, "2025-05-31T13:59:01", "waveform")
assert e.peaks_ips == {"tran": 0.1, "vert": 0.15, "long": 0.05}
assert e.filename == "UM20147_20250531135901.IDFW"
assert e.detail["mic"] == 0.0002 and e.detail["size_bytes"] > 0
def test_download_walks_to_the_event_and_uses_thors_chunk_size():
fake = FakeMicromateClient()
dl = s4_download_event(fake, "UM20147", W_KEY, "20250531135901")
assert "iter_events" in fake.calls and "list_events" not in fake.calls
assert fake.fetched == [("055d4a81", THOR_CHUNK_SIZE)]
assert dl.idf_bytes == (THOR_IDF / "UM20147_20250531135901.IDFW").read_bytes()
assert (dl.series, dl.filename, dl.verified) == (4, "UM20147_20250531135901.IDFW", True)
def test_download_carries_the_units_timestamp_and_its_own_record():
# What the unit's 0x0C said: the store looks up an existing row by the
# timestamp, and fills what the file alone cannot give from the record.
ref = FakeMicromateClient().event_refs[0]
ref.sensor_location, ref.setup = "Loc A", "test2"
fake = FakeMicromateClient(event_refs=[ref])
dl = s4_download_event(fake, "UM20147", W_KEY, "20250531135901")
assert dl.timestamp == datetime.datetime(2025, 5, 31, 13, 59, 1)
assert dl.record == {"peak_vector_sum_ips": 0.2, "sensor_location": "Loc A", "setup": "test2"}
def test_the_walk_stops_at_the_event_rather_than_reading_ahead():
fake = FakeMicromateClient()
s4_download_event(fake, "UM20147", W_KEY, None)
assert fake.cursor == 0
def test_a_histogram_has_no_self_check_so_verified_is_none():
dl = s4_download_event(FakeMicromateClient(), "UM20147", H_KEY, None)
assert dl.verified is None and dl.filename.endswith(".IDFH")
def test_a_stale_id_is_refused_and_nothing_is_downloaded():
fake = FakeMicromateClient()
with pytest.raises(StaleEvent, match="20250531135901"):
s4_download_event(fake, "UM20147", W_KEY, "20240101000000")
assert fake.fetched == []
def test_a_key_that_is_not_stored_is_404():
with pytest.raises(EventNotFound):
s4_download_event(FakeMicromateClient(), "UM20147", bytes.fromhex("deadbeef"), None)
-71
View File
@@ -1,71 +0,0 @@
"""The event .h5 carries the sensor self-check traces (schema v2).
The sensor check is decoded by the per-series decoder and attached to the
standardized Event, so the .h5 writer persists it device-agnostically and SFM
reads it back without knowing which instrument produced it. Old v1 files (no
sensor_check group) must still read cleanly.
"""
import tempfile
from pathlib import Path
import numpy as np
from minimateplus.models import Event
from minimateplus.event_file_io import read_blastware_file
from sfm import event_hdf5
S3_FIX = Path(__file__).parent / "fixtures" / "fft-oracle-2026-09-14" / "N844LQHB.ZT0W"
def _write(ev, **kw):
d = Path(tempfile.mkdtemp())
p = d / "e.h5"
event_hdf5.write_event_hdf5(p, ev, serial="BE12844", **kw)
return p
def test_sensor_check_roundtrips_through_hdf5():
ev = Event(index=0)
ev.raw_samples = {"Tran": [1, 2, -3], "Vert": [0, 1], "Long": [2], "MicL": [5, -5]}
ev.sample_rate = 1024
sc = {"Tran": [0, -990, -500, -100], "Vert": [0, -980, -480],
"Long": [0, -986, -470], "MicL": [0, -1800, 1800, -1800]}
ev.sensor_check = sc
r = event_hdf5.read_event_hdf5(_write(ev))
assert r["schema_version"] == 2
assert set(r["sensor_check"]) == {"Tran", "Vert", "Long", "MicL"}
for ch, vals in sc.items():
assert r["sensor_check"][ch].tolist() == vals
def test_plot_json_carries_sensor_check():
ev = Event(index=0)
ev.raw_samples = {"Tran": [1, 2, 3]}
ev.sample_rate = 1024
ev.sensor_check = {"Tran": [0, -990, -500], "Vert": [0, -980],
"Long": [0, -986]} # 3-channel: no MicL
pj = event_hdf5.plot_json_from_hdf5(_write(ev))
assert pj["sensor_check"] is not None
assert "MicL" not in pj["sensor_check"]
assert pj["sensor_check"]["Tran"] == [0, -990, -500]
def test_event_without_sensor_check_still_reads_as_v2():
ev = Event(index=0)
ev.raw_samples = {"Tran": [1, 2, 3]}
ev.sample_rate = 1024
r = event_hdf5.read_event_hdf5(_write(ev))
assert r["schema_version"] == 2
assert r["sensor_check"] is None
assert event_hdf5.plot_json_from_hdf5(_write(ev))["sensor_check"] is None
def test_series3_decode_populates_event_sensor_check():
# The real series-3 decoder attaches the traces to the Event, so the
# ingest/backfill .h5 write picks them up with no extra plumbing.
ev = read_blastware_file(S3_FIX)
assert ev.sensor_check is not None
assert set(ev.sensor_check) == {"Tran", "Vert", "Long", "MicL"}
tran = np.asarray(ev.sensor_check["Tran"], dtype=float)
assert tran.min() < -800 # the geophone ring-down deflection
-247
View File
@@ -1,247 +0,0 @@
"""Storing a downloaded event: the same store + DB writes every ingest path makes."""
from __future__ import annotations
import datetime
import os
import sys
from pathlib import Path
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from device_access_fakes import FakeMiniMateClient, s3_event # noqa: E402
from sfm.database import SeismoDb # noqa: E402
from sfm.device_access.models import DownloadedEvent # noqa: E402
from sfm.event_ingest import IngestError, backfill_series3_event, persist_download # noqa: E402
from sfm.waveform_store import WaveformStore # noqa: E402
THOR_IDF = Path(__file__).parent / "fixtures" / "thor-idf"
BW_FIXTURES = Path(__file__).parent / "fixtures" / "5-11-26"
@pytest.fixture
def sdm(tmp_path):
return WaveformStore(tmp_path / "waveforms"), SeismoDb(tmp_path / "seismo.db")
def s4_download(name, verified=True, record=None):
return DownloadedEvent(event_id=f"UM20147:055d4a81:{name[8:22]}", serial="UM20147", series=4,
filename=name, verified=verified, idf_bytes=(THOR_IDF / name).read_bytes(),
timestamp=datetime.datetime.strptime(name[8:22], "%Y%m%d%H%M%S"),
record=dict(record or {}))
def _tree(root):
"""Every file under the store: (size, mtime_ns). Any write shows."""
return {str(p.relative_to(root)): (p.stat().st_size, p.stat().st_mtime_ns)
for p in sorted(root.rglob("*")) if p.is_file()}
def _age_files(directory):
"""Back-date every file, so a rewrite shows in its mtime whatever the clock's grain."""
for p in directory.iterdir():
if p.is_file():
os.utime(p, ns=(1_000_000_000_000_000_000, 1_000_000_000_000_000_000))
def test_a_series4_waveform_is_stored_and_findable(sdm):
store, db = sdm
out = persist_download(s4_download("UM20147_20250531135901.IDFW"), store=store, db=db)
assert out.stored_filename == "UM20147_20250531135901.IDFW" and out.inserted
assert (store.root / "UM20147" / out.stored_filename).exists()
row = db.get_event(out.db_event_id)
assert row["serial"] == "UM20147" and row["device_family"] == "series4"
assert out.verified is True and out.sha256
def test_a_fresh_series4_download_keeps_the_units_pvs_and_sensor_location(sdm):
# Without Thor's TXT the file alone gives only the three PPVs; the unit's
# 0x0C record carries the vector sum (find_twins matches on it) and the location.
store, db = sdm
out = persist_download(s4_download("UM20147_20250531135901.IDFW",
record={"peak_vector_sum_ips": 0.391, "sensor_location": "Loc A"}),
store=store, db=db)
row = db.get_event(out.db_event_id)
assert out.inserted
assert (row["peak_vector_sum"], row["sensor_location"]) == (0.391, "Loc A")
assert row["tran_ppv"] is not None # the file's own peaks still stored
def test_the_record_fills_only_what_the_file_left_empty(sdm, monkeypatch):
store, db = sdm
real = store.save_imported_idf
def with_values(*a, **kw):
ev, rec = real(*a, **kw)
ev.peak_values.peak_vector_sum = 1.5
ev.project_info.sensor_location = "From the file"
return ev, rec
monkeypatch.setattr(store, "save_imported_idf", with_values)
out = persist_download(s4_download("UM20147_20250531135901.IDFW",
record={"peak_vector_sum_ips": 0.391, "sensor_location": "Loc A"}),
store=store, db=db)
row = db.get_event(out.db_event_id)
assert (row["peak_vector_sum"], row["sensor_location"]) == (1.5, "From the file")
def test_the_record_is_kept_even_when_the_file_gave_no_peaks_or_project(sdm, monkeypatch):
store, db = sdm
real = store.save_imported_idf
def bare(*a, **kw):
ev, rec = real(*a, **kw)
ev.peak_values = ev.project_info = None
return ev, rec
monkeypatch.setattr(store, "save_imported_idf", bare)
out = persist_download(s4_download("UM20147_20250531135901.IDFW",
record={"peak_vector_sum_ips": 0.391, "sensor_location": "Loc A"}),
store=store, db=db)
row = db.get_event(out.db_event_id)
assert (row["peak_vector_sum"], row["sensor_location"]) == (0.391, "Loc A")
def test_a_series4_histogram_is_stored(sdm):
store, db = sdm
out = persist_download(s4_download("UM20147_20250330070110.IDFH", verified=None), store=store, db=db)
assert out.inserted and out.db_event_id and out.verified is None
def test_storing_the_same_event_twice_stores_nothing_the_second_time(sdm):
store, db = sdm
name = "UM20147_20250531135901.IDFW"
first = persist_download(s4_download(name), store=store, db=db)
_age_files(store.root / "UM20147")
row0 = db.get_event(first.db_event_id)
tree0 = _tree(store.root)
again = persist_download(s4_download(name), store=store, db=db)
assert (first.inserted, again.inserted) == (True, False)
assert again.db_event_id == first.db_event_id and again.detail["already_stored"] is True
assert db.query_events(serial="UM20147") == [row0]
assert (store.root / "UM20147" / name).stat().st_mtime_ns == tree0[f"UM20147/{name}"][1]
assert _tree(store.root) == tree0
# ── an event THOR's watcher (or Blastware's ACH) already stored ───────────────
# Built exactly as /db/import/idf_file and /db/import/blastware_file build it
# (sfm/server.py): the store's import call, then insert_events.
def watcher_import_idf(store, db, name):
ev, rec = store.save_imported_idf((THOR_IDF / name).read_bytes(), source_path=Path(name),
serial_hint=None, idf_report_text=None)
serial = rec.get("serial") or "UNKNOWN"
db.insert_events([ev], serial=serial,
waveform_records={ev._waveform_key.hex(): rec} if ev._waveform_key else None,
device_family="series4")
return serial, rec
def watcher_import_bw(store, db, name):
ev, rec = store.save_imported_bw((BW_FIXTURES / name).read_bytes(), source_path=Path(name),
serial_hint=None,
bw_report_text=(BW_FIXTURES / f"{name}.TXT").read_bytes())
serial = rec.get("serial") or "UNKNOWN"
db.insert_events([ev], serial=serial,
waveform_records={ev._waveform_key.hex(): rec if ev._waveform_key else None}
if ev._waveform_key else None,
device_family="series3")
return serial, rec
def test_downloading_an_event_the_watcher_stored_writes_nothing_series4(sdm):
store, db = sdm
name = "UM20147_20250531135901.IDFW"
serial, rec = watcher_import_idf(store, db, name)
assert serial == "UM20147"
# Something only the stored copy has; a rewrite of the sidecar would drop it.
assert store.patch_sidecar(serial, name, extensions={"operator_note": {"text": "checked on site"}})
_age_files(store.root / serial)
[row0] = db.query_events(serial=serial)
sidecar0 = store.sidecar_path_for(serial, name).read_bytes()
mtime0 = (store.root / serial / name).stat().st_mtime_ns
tree0 = _tree(store.root)
out = persist_download(s4_download(name, record={"peak_vector_sum_ips": 0.391,
"sensor_location": "Loc A"}),
store=store, db=db)
assert out.inserted is False and out.detail["already_stored"] is True
assert out.db_event_id == row0["id"]
assert (out.stored_filename, out.filesize) == (name, rec["filesize"])
assert db.query_events(serial=serial) == [row0]
assert store.sidecar_path_for(serial, name).read_bytes() == sidecar0
assert (store.root / serial / name).stat().st_mtime_ns == mtime0
assert _tree(store.root) == tree0
class RecordingStore:
def __init__(self):
self.saved = []
def save(self, ev, serial, a5_frames, *, geo_range="normal", source_kind="sfm-live"):
self.saved.append((ev, serial, a5_frames, geo_range))
return {"filename": "T193LQ9K.OE0", "filesize": 8708, "sha256": "ab" * 32}
def test_a_series3_event_is_backfilled_then_stored_as_series3(tmp_path):
db = SeismoDb(tmp_path / "seismo.db")
store = RecordingStore()
fake = FakeMiniMateClient()
ev = s3_event(0, "01110000", datetime.datetime(2026, 10, 1, 8, 0, 0))
dl = DownloadedEvent(event_id="BE18193:01110000:20261001080000", serial="BE18193", series=3,
filename="T193LQ9K.OE0", verified=None, event=ev, a5_frames=["frame"],
compliance=fake.compliance, timestamp=datetime.datetime(2026, 10, 1, 8, 0, 0))
out = persist_download(dl, store=store, db=db)
saved_ev, serial, frames, geo_range = store.saved[0]
assert (serial, frames, geo_range) == ("BE18193", ["frame"], 0)
assert saved_ev.sample_rate == 1024 and saved_ev.rectime_seconds == 3.0
assert db.get_event(out.db_event_id)["device_family"] == "series3"
assert out.stored_filename == "T193LQ9K.OE0"
def test_downloading_an_event_the_watcher_stored_writes_nothing_series3(tmp_path):
db = SeismoDb(tmp_path / "seismo.db")
serial, rec = watcher_import_bw(WaveformStore(tmp_path / "waveforms"), db, "M529LL1L.V70")
[row0] = db.query_events(serial=serial)
when = datetime.datetime.fromisoformat(row0["timestamp"])
# The download's own decode differs from the stored row (peaks, file name), so
# any write would show in the row.
ev = s3_event(0, row0["waveform_key"], when)
store = RecordingStore()
dl = DownloadedEvent(event_id=f"{serial}:{row0['waveform_key']}:{when:%Y%m%d%H%M%S}",
serial=serial, series=3, filename="M529LL1L.V70", verified=None, event=ev,
a5_frames=["frame"], compliance=FakeMiniMateClient().compliance,
timestamp=when)
out = persist_download(dl, store=store, db=db)
assert store.saved == []
assert db.query_events(serial=serial) == [row0]
assert out.inserted is False and out.detail["already_stored"] is True
assert (out.db_event_id, out.stored_filename, out.filesize) == (row0["id"], rec["filename"],
rec["filesize"])
assert ev.sample_rate is None # not even backfilled
def test_a_series3_download_with_no_event_stores_nothing_and_says_so(tmp_path):
store = RecordingStore()
dl = DownloadedEvent(event_id="BE18193:01110000:-", serial="BE18193", series=3,
filename="T193LQ9K.OE0", verified=None, event=None, a5_frames=["frame"])
with pytest.raises(IngestError, match="nothing was stored"):
persist_download(dl, store=store, db=SeismoDb(tmp_path / "seismo.db"))
assert store.saved == []
def test_backfill_derives_total_samples_only_when_the_decoded_one_is_implausible():
cc = FakeMiniMateClient().compliance # 1024 sps, 3.0 s
ev = s3_event(0, "01110000", datetime.datetime(2026, 10, 1))
ev.total_samples = 40_000
backfill_series3_event(ev, cc)
assert ev.total_samples == 3072
ev.total_samples = 3000
backfill_series3_event(ev, cc)
assert ev.total_samples == 3000
def test_backfill_without_settings_changes_nothing():
ev = s3_event(0, "01110000", datetime.datetime(2026, 10, 1))
backfill_series3_event(ev, None)
assert ev.sample_rate is None
-54
View File
@@ -1,54 +0,0 @@
"""Event timestamp decode — waveform trigger/stop vs histogram window start.
The Blastware footer holds two timestamps: ts1 = footer[2:10], ts2 = footer[10:18].
Their meaning depends on record type:
* Waveform: ts1 is the monitoring-SESSION start (e.g. 06:00 for a unit that
arms at 06:00 daily — shared across every event that day), and ts2 is THIS
event's recording STOP. read_blastware_file used to stamp events with ts1 →
every waveform showed the session start (~4.5 h off). Binary-only, the best
estimate is ts2 (the stop); the exact trigger BW displays (= ts2 - record
duration) comes from the paired report's event_datetime, since the binary
STRT record-time byte is a misparsed record-type marker.
* Histogram: ts1/ts2 are the ~24 h window [start, stop]; the event time is the
window start = ts1 (unchanged).
"""
import datetime
from pathlib import Path
from minimateplus.event_file_io import read_blastware_file, apply_report_to_event
from minimateplus.bw_ascii_report import BwAsciiReport
from minimateplus.models import Event
FIX = Path(__file__).parent / "fixtures"
WAVEFORM = FIX / "fft-oracle-2026-09-14" / "N844LQHB.ZT0W" # footer ts2 = 2026-08-25 10:33:32
HISTOGRAM = FIX / "ts-fix" / "K441LKZU.C30H" # window start 2026-05-10 19:04:50
def _tuple(ts):
return (ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
def test_waveform_timestamp_is_exact_trigger_from_binary():
ev = read_blastware_file(WAVEFORM)
# The EXACT Blastware trigger, from the binary alone: ts2 (stop 10:33:32)
# minus the config record time (3.0 s) = 10:33:29 — NOT the 06:00:13
# monitoring-session start the old decode used.
assert _tuple(ev.timestamp) == (2026, 8, 25, 10, 33, 29), _tuple(ev.timestamp)
def test_histogram_timestamp_is_window_start_unchanged():
ev = read_blastware_file(HISTOGRAM)
# Histogram event time = the window start (ts1); must NOT get the waveform
# ts2 treatment (that would land ~24 h off).
assert _tuple(ev.timestamp) == (2026, 5, 10, 19, 4, 50), _tuple(ev.timestamp)
def test_report_event_datetime_is_authoritative_over_binary():
# The binary already yields the exact trigger, but a paired report stays
# authoritative (e.g. if the unit clock had drifted) — applying it wins.
ev = read_blastware_file(WAVEFORM)
assert _tuple(ev.timestamp) == (2026, 8, 25, 10, 33, 29) # exact, from binary
apply_report_to_event(ev, BwAsciiReport(
event_datetime=datetime.datetime(2026, 8, 25, 10, 35, 0)))
assert _tuple(ev.timestamp) == (2026, 8, 25, 10, 35, 0) # report wins
-322
View File
@@ -1,322 +0,0 @@
"""Per-sample verification of the Thor / Micromate (series-4) IDF binary codec.
Ground truth is Thor's own CSV export, written next to each binary by the
Thor desktop application. For waveforms the export carries a per-sample
block of four columns (Tran, Vert, Long, Mic) in in/s and psi -- the
series-4 equivalent of Blastware's ``_ASCII.TXT`` exports.
The full-corpus harness is ``scratch/verify_thor_against_csv.py``; these
tests pin the two constants that harness established so they cannot
regress silently.
"""
from __future__ import annotations
import csv
import os
import sys
from pathlib import Path
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from micromate.idf_file import (
_GEO_LSB_IPS,
geo_count_to_ips,
read_idf_file,
)
FIXTURES = Path(__file__).parent / "fixtures" / "thor-idf"
IDFW = FIXTURES / "UM11719_20231219162723.IDFW"
IDFH = FIXTURES / "UM11719_20231219162648.IDFH"
GEO_CHANNELS = ("Tran", "Vert", "Long")
# tests/fixtures/ is gitignored, so a fresh checkout has no sample data.
# Skip rather than fail, matching test_idf_ascii_report.py. To populate:
#
# B="<thor-watcher>/example-data/THORDATA_example/THORDATA_example/UPMC Presby"
# mkdir -p tests/fixtures/thor-idf
# for f in UM11719/UM11719_20231219162723.IDFW \
# UM11719/UM11719_20231219162648.IDFH \
# UM13981/UM13981_20220207084555.IDFW \
# UM13981/UM13981_20220207183102.IDFH \
# UM13981/UM13981_20221202063059.IDFH; do
# cp "$B/$f" tests/fixtures/thor-idf/
# cp "$B/$(dirname $f)/CSV/$(basename $f).csv" tests/fixtures/thor-idf/
# done
pytestmark = pytest.mark.skipif(
not FIXTURES.is_dir() or not any(FIXTURES.glob("*.IDFW")),
reason=f"Thor IDF fixtures not present under {FIXTURES}",
)
def _parse_export(path: Path):
"""Split a Thor CSV export into (header dict, per-sample rows)."""
header, rows = {}, []
with path.open(newline="", encoding="utf-8", errors="replace") as fh:
for rec in csv.reader(fh):
if len(rec) == 2:
header[rec[0].strip()] = rec[1].strip()
elif len(rec) >= 3:
try:
rows.append([float(x) for x in rec])
except ValueError:
pass
return header, rows
def _header_float(header, key):
return float(header[key].split()[0])
@pytest.fixture(scope="module")
def idfw_export():
return _parse_export(IDFW.with_suffix(".IDFW.csv"))
# ─── The geo scale constant ────────────────────────────────────────────────
def test_geo_lsb_matches_thor_quantisation():
"""Thor's own export quantises geo samples to this LSB.
Derived by maximising exact-match count over 1,046,016 paired samples
(454 channel-events, 2 units); independently corroborated on 8
production units via their device-reported PPV. The historical value
0.0003 read every series-4 geophone sample 3.3% low.
"""
assert _GEO_LSB_IPS == pytest.approx(0.000310308, rel=1e-6)
def test_geo_lsb_is_not_the_legacy_value():
# Guards against a revert to the truncated 0.0003 constant.
assert abs(_GEO_LSB_IPS - 0.0003) > 1e-6
# ─── Per-sample fidelity ───────────────────────────────────────────────────
def test_waveform_channel_lengths_match_export(idfw_export):
_header, rows = idfw_export
result = read_idf_file(IDFW)
for channel in GEO_CHANNELS:
assert len(result.samples[channel]) == len(rows), (
f"{channel} truncated: decoded {len(result.samples[channel])} "
f"samples, export has {len(rows)}"
)
def test_waveform_samples_match_export_exactly(idfw_export):
"""Every geo sample must reproduce Thor's exported value to 4 dp."""
_header, rows = idfw_export
result = read_idf_file(IDFW)
for index, channel in enumerate(GEO_CHANNELS):
decoded = result.samples[channel]
expected = [row[index] for row in rows]
mismatches = [
(i, geo_count_to_ips(c), v)
for i, (c, v) in enumerate(zip(decoded, expected))
if abs(geo_count_to_ips(c) - v) >= 5e-5
]
assert not mismatches, (
f"{channel}: {len(mismatches)} of {len(expected)} samples differ; "
f"first three {mismatches[:3]}"
)
def test_waveform_ppv_matches_export(idfw_export):
header, _rows = idfw_export
result = read_idf_file(IDFW)
for channel, attr in (
("Tran", "transverse_ips"),
("Vert", "vertical_ips"),
("Long", "longitudinal_ips"),
):
decoded = getattr(result.event.peaks, attr)
assert decoded == pytest.approx(
_header_float(header, f"{channel}PPV"), abs=5e-5
), f"{channel} PPV disagrees with Thor's export"
# ─── Histogram path shares the same scale ──────────────────────────────────
def test_histogram_peaks_match_export():
header, _rows = _parse_export(IDFH.with_suffix(".IDFH.csv"))
result = read_idf_file(IDFH)
assert result.intervals, "IDFH decoded no intervals"
for channel, attr in (
("Tran", "transverse_ips"),
("Vert", "vertical_ips"),
("Long", "longitudinal_ips"),
):
decoded = getattr(result.event.peaks, attr)
expected = _header_float(header, f"{channel}PPV")
# Histogram peaks are stored per-interval, so the export's PPV is
# reproduced within one quantisation step rather than exactly.
assert decoded == pytest.approx(expected, abs=2 * _GEO_LSB_IPS), (
f"{channel} histogram peak {decoded} vs export {expected}"
)
# ─── Regressions found 2026-09-10 ──────────────────────────────────────────
IDFH_LONG = FIXTURES / "UM13981_20220207183102.IDFH" # 719 intervals
IDFH_SENTINEL = FIXTURES / "UM13981_20221202063059.IDFH" # holds an unwritten slot
IDFW_RAW16 = FIXTURES / "UM13981_20220207084555.IDFW" # segment 0 is MODE_RAW16
def test_histogram_decodes_past_250_intervals():
"""The segment validator must not require a zero counter high byte.
The interval counter is a uint16 cumulative index. Requiring its high
byte to be zero rejected every segment past interval 255, capping each
histogram at 250 intervals and truncating any run longer than ~4 hours —
frequently discarding the part that held the peak.
"""
result = read_idf_file(IDFH_LONG)
header, _rows = _parse_export(IDFH_LONG.with_suffix(".IDFH.csv"))
expected = float(header["NumberOfIntervals"])
assert len(result.intervals) == 719
assert len(result.intervals) == pytest.approx(expected, abs=1.0)
def test_histogram_ignores_unwritten_interval_slot():
"""A never-written interval keeps its ±full-scale seed and must be dropped.
Counting it fabricates a 10.0 in/s peak on every channel, which then wins
the max-over-intervals and poisons the whole file's PPV.
"""
header, _rows = _parse_export(IDFH_SENTINEL.with_suffix(".IDFH.csv"))
result = read_idf_file(IDFH_SENTINEL)
for channel, attr in (
("Tran", "transverse_ips"),
("Vert", "vertical_ips"),
("Long", "longitudinal_ips"),
):
decoded = getattr(result.event.peaks, attr)
assert decoded < 1.0, f"{channel} peak {decoded} looks like the ±FS seed"
assert decoded == pytest.approx(
_header_float(header, f"{channel}PPV"), abs=2 * _GEO_LSB_IPS
)
def test_waveform_raw16_segment_zero_is_decoded():
"""Segment-0 records can be raw int16 (MODE_RAW16, 10-byte header).
That mode was absent from the dispatch, so the record fell through
unhandled and the channel silently lost its first 512 samples.
"""
rows = _parse_export(IDFW_RAW16.with_suffix(".IDFW.csv"))[1]
result = read_idf_file(IDFW_RAW16)
for index, channel in enumerate(GEO_CHANNELS):
decoded = result.samples[channel]
assert len(decoded) == len(rows), f"{channel} lost segment 0"
expected = [row[index] for row in rows]
bad = sum(
1 for c, v in zip(decoded, expected)
if abs(geo_count_to_ips(c) - v) >= 5e-5
)
assert bad == 0, f"{channel}: {bad} samples differ from Thor's export"
def test_body_offset_search_is_not_quadratic():
"""The body scan must stay cheap enough for bulk ingest.
MODE_RAW16 is (0x00, 0x00), so scanning for candidate *preambles* treats
every run of three zero bytes as a body start and trial-decodes each one
(~0.5 s/file measured). The search anchors on record headers instead.
"""
import time
start = time.perf_counter()
for _ in range(3):
read_idf_file(IDFW_RAW16)
elapsed = (time.perf_counter() - start) / 3
assert elapsed < 0.15, f"body-offset search took {elapsed*1000:.0f} ms/file"
# ─── Mic-disabled (3-channel) units, found 2026-09-10 ──────────────────────
IDFW_3CH = FIXTURES / "UM20147_20250531135901.IDFW" # body head below old floor
IDFH_3CH = FIXTURES / "UM20147_20250330070110.IDFH" # 56-byte interval records
def test_three_channel_waveform_decodes_all_geo_channels():
"""A mic-disabled unit's shorter header moves the record chain head.
Its head sits at 0x0dba, below the old ``_BODY_SCAN_FLOOR`` of 0x0E00, so
the scan could not see it and fell through to the *Vert* segment-0 record
— decoding a body shifted one position around the channel rotation, which
surfaced as Vert being exactly 512 samples short.
"""
rows = _parse_export(IDFW_3CH.with_suffix(".IDFW.csv"))[1]
result = read_idf_file(IDFW_3CH)
for index, channel in enumerate(GEO_CHANNELS):
decoded = result.samples[channel]
assert len(decoded) == len(rows), (
f"{channel}: {len(decoded)} samples, export has {len(rows)}"
)
expected = [row[index] for row in rows]
bad = sum(
1 for c, v in zip(decoded, expected)
if abs(geo_count_to_ips(c) - v) >= 5e-5
)
assert bad == 0, f"{channel}: {bad} samples differ from Thor's export"
# Mic is genuinely absent on these units, not merely undecoded.
assert not result.samples.get("MicL")
def test_three_channel_histogram_uses_56_byte_intervals():
"""Interval stride is 16 bytes per channel + an 8-byte tail, not a constant.
A mic-disabled unit packs 56-byte records, so assuming 72 read 7 intervals
out of every 10-interval segment and then walked off alignment into
garbage, which decoded as ~10 in/s peaks. The true count comes from the
segment's cumulative interval counter.
"""
header, _rows = _parse_export(IDFH_3CH.with_suffix(".IDFH.csv"))
result = read_idf_file(IDFH_3CH)
expected_intervals = float(header["NumberOfIntervals"])
assert len(result.intervals) == pytest.approx(expected_intervals, abs=1.0)
assert {iv.n_channels for iv in result.intervals} == {3}
for channel, attr in (
("Tran", "transverse_ips"),
("Vert", "vertical_ips"),
("Long", "longitudinal_ips"),
):
decoded = getattr(result.event.peaks, attr)
assert decoded < 1.0, f"{channel} peak {decoded} looks like walked-off garbage"
assert decoded == pytest.approx(
_header_float(header, f"{channel}PPV"), rel=0.02
)
# ─── `40 NN` blocks with NN > 8, verified 2026-09-11 ───────────────────────
IDFW_WIDE40 = FIXTURES / "UM12947_20250806134504.IDFW"
def test_wide_forty_nn_block_does_not_truncate_channels():
"""Loud events use `40 NN` blocks with NN well above the old cap of 8.
``data_block_len()`` rejected NN > 0x08, which halted the block walk
part-way through a record. The walker stops at the first unrecognised
tag instead of raising, so this surfaced as silently short channels —
here Tran 1812 / Vert 2132 / Long 2324 where the export has 2324 for all
three. The affected files use NN of 12, 16, 20 ... up to 196.
"""
rows = _parse_export(IDFW_WIDE40.with_suffix(".IDFW.csv"))[1]
result = read_idf_file(IDFW_WIDE40)
for index, channel in enumerate(GEO_CHANNELS):
decoded = result.samples[channel]
assert len(decoded) == len(rows), (
f"{channel}: {len(decoded)} samples, export has {len(rows)}"
)
expected = [row[index] for row in rows]
bad = sum(
1 for c, v in zip(decoded, expected)
if abs(geo_count_to_ips(c) - v) >= 5e-5
)
assert bad == 0, f"{channel}: {bad} samples differ from Thor's export"
Loaded 100 of 113 files, more files were not shown because too many files have changed in this diff. Show more