583 changed files with 10197 additions and 220538 deletions

No files matched your search

-28
View File
@@ -1,28 +0,0 @@
.git
.gitignore
.venv
venv
env
__pycache__
*.pyc
*.pyo
*.pyd
.pytest_cache
.mypy_cache
.ruff_cache
*.db
*.db-wal
*.db-shm
*.sqlite
*.sqlite3
sfm/data
bridges/captures
example-events
captures
logs
.DS_Store
Thumbs.db
-28
View File
@@ -1,28 +0,0 @@
# Line endings (2026-11-12): every text file is stored and checked out with LF,
# whatever tool or OS wrote it -- file types we have not invented yet included.
# The protocol reference and seismo_lab.py were CRLF, so any rewrite outside the
# Edit tool turned them into whole-file diffs, and merges into them had to be
# resolved byte by byte. Same rule as Terra-View's. tests/test_line_endings.py
# fails if a CRLF file gets in anyway.
* text=auto eol=lf
# Binary -- never converted.
*.bin binary
*.pdf binary
*.png binary
*.jpg binary
*.jpeg binary
*.gif binary
*.ico binary
*.h5 binary
*.pkl binary
*.db binary
*.sqlite binary
*.zip binary
*.gz binary
*.xlsx binary
*.docx binary
# Test fixtures are recorded bytes -- Blastware's own reports and exports, unit
# captures, event files -- kept byte for byte as ground truth: never converted.
tests/fixtures/** -text
+33 -43
View File
@@ -1,43 +1,33 @@
/bridges/captures/
# Capture artefacts that land beside the bridge scripts. Deliberately NOT
# `/bridges/s3-bridge/` -- proxy.py and s3_bridge.py live there and are tracked.
/bridges/*.bin
/bridges/s3-bridge/*.bin
/bridges/s3-bridge/*.log
/bridges/s3-bridge/*.set
/example-events
/tests/fixtures/
/manuals/
# Python build artifacts
*.egg-info/
dist/
build/
# Python bytecode
__pycache__/
*.py[cod]
# Virtual environments
.venv/
venv/
env/
# Editor / OS
.vscode/
*.swp
.DS_Store
Thumbs.db
# Analyzer outputs
*.report
claude_export_*.md
# Frame database
*.db
*.db-wal
*.db-shm
# Config-block snapshots from scratch/mm_config_diff.py (device dumps, not source)
scratch/mm_config_snaps/
/bridges/captures/
/example-events/
/manuals/
# Python build artifacts
*.egg-info/
dist/
build/
# Python bytecode
__pycache__/
*.py[cod]
# Virtual environments
.venv/
venv/
env/
# Editor / OS
.vscode/
*.swp
.DS_Store
Thumbs.db
# Analyzer outputs
*.report
claude_export_*.md
# Frame database
*.db
*.db-wal
*.db-shm
-2989
View File
File diff suppressed because it is too large. Load diff
+13 -1152
View File
File diff suppressed because it is too large. Load diff
-33
View File
@@ -1,33 +0,0 @@
FROM python:3.11-slim
WORKDIR /app
# tzdata is required for the TZ env var to take effect (python:slim
# omits the timezone database). Without it, datetime.now() / logging
# / matplotlib all stay in UTC regardless of TZ. Default zone gets
# set further down via ENV; users override per-deployment via the
# `TZ` env var in docker-compose.
RUN apt-get update && \
apt-get install -y --no-install-recommends curl tzdata && \
rm -rf /var/lib/apt/lists/*
# Default display timezone — applied to server logs, datetime.now(),
# matplotlib rendered timestamps, and any naïve-vs-aware datetime
# conversions in the PDF renderer. Override via TZ env var in
# docker-compose; storage in the DB is always UTC regardless.
ENV TZ=America/New_York
# The product and its maintenance scripts (the backfills run in this
# container). The bench and lab tools -- bridges/, scratch/, seismo_lab.py --
# stay out of the image (ADR 0003; SFM imports nothing from them).
COPY pyproject.toml requirements.txt ./
COPY minimateplus ./minimateplus
COPY micromate ./micromate
COPY sfm ./sfm
COPY scripts ./scripts
RUN pip install --no-cache-dir -e .
EXPOSE 8200
CMD ["python", "-m", "uvicorn", "sfm.server:app", "--host", "0.0.0.0", "--port", "8200"]
+34 -419
View File
@@ -1,11 +1,7 @@
# seismo-relay `v0.35.0`
# seismo-relay `v0.15.0`
A ground-up replacement for **Blastware** — Instantel's aging Windows-only
software for managing seismographs. Supports both the **MiniMate Plus
(Series III)** and the **Micromate (Series IV / "Thor")** families:
Series III via the live RS-232 / TCP wire protocol *and* Blastware ACH file
ingest; Series IV via Thor IDF file ingest (binary codec verified per-sample
against Thor's own exports), plus a read-only live client in `micromate/`.
software for managing MiniMate Plus seismographs.
Built in Python. Runs on Windows, Linux, or macOS. Connects to instruments
over direct RS-232 or cellular modem (Sierra Wireless RV50 / RV55).
@@ -18,116 +14,11 @@ over direct RS-232 or cellular modem (Sierra Wireless RV50 / RV55).
> byte-perfect against Blastware captures across 2-sec, 3-sec, and 10-sec
> events.** Generated `.G10` / `.AB0` files open cleanly in Blastware with
> full Event Reports, frequency analysis, and waveform plots.
> **v0.16.0 (2026-05-11)** adds BW ASCII report ingestion to
> `/db/import/blastware_file` — paired with **series3-watcher v1.5.0**,
> every Blastware ACH event lands in SeismoDb with device-authoritative
> peaks, project metadata, sensor self-check, and ZC/Time-of-Peak data,
> without depending on the still-undecoded waveform body codec.
> **v0.18.0 (2026-05-19)** adds Thor / Micromate Series IV ingest at
> `/db/import/idf_file` — paired with **thor-watcher v0.3.0**, every
> `.IDFH` / `.IDFW` event file (plus its `.txt` sidecar) lands in
> SeismoDb the same way BW events do. See
> [`docs/idf_protocol_reference.md`](docs/idf_protocol_reference.md) for
> the IDF format reference and reverse-engineering plan.
> **v0.19.0 (2026-05-20)** separates Series III and Series IV at the
> code level: new `micromate/` package alongside `minimateplus/`, new
> `events.device_family` DB column ("series3" / "series4") so the UI
> and storage layer dispatch deterministically instead of sniffing
> filenames. Self-applying migration backfills existing rows from the
> binary filename extension.
> **v0.20.0 (2026-05-28)** closes out the Event-Report PDF iteration
> started in v0.17.x: histogram layouts render correctly against BW
> reference PDFs, the ASCII parser handles real-world edge cases
> (`OORANGE`, `>100 Hz`, histogram timestamps), and per-channel ZC
> Freq is surfaced in both modals (event browser + main webapp).
> Adds a server-wide `TZ` env var so operator-visible timestamps
> render in local time instead of UTC. New
> `scripts/backfill_sidecars.py --reparse-txt` lets parser fixes be
> applied retroactively to existing events without re-forwarding,
> using the `.TXT` files preserved at ingest time.
> **v0.21.0 (2026-05-29)** is the Thor / Series IV decoder release —
> `micromate/idf_file.read_idf_file()` now decodes both IDFW
> (waveform) and IDFH (histogram) binaries (87–99% sample fidelity
> on quiet IDFW events; all 859 IDFH corpus files decode cleanly).
> A new `micromate/idf_to_bw_report.py` adapter projects parsed
> Thor reports into the BW-shaped sidecar block, so Thor events
> flow through the existing Event Report PDF pipeline without a
> separate renderer. Terra-View v0.13.0 ships in parallel and
> closes Phase 1 of the SFM integration — see its CHANGELOG.
> **v0.22.0 (2026-07-03)** adds the SFM side of the full-snapshot
> bundle: `GET /db/snapshot` (WAL-safe DB copy), `GET /db/waveforms/
> recent.zip` (recent events' waveform files), and a gated
> `POST /db/restore` (`SFM_DB_RESTORE_ENABLED`, dev-only). Terra-View
> v0.17.0 drives them to pull a one-pass prod→dev refresh.
> **v0.32.0 (2026-10-27)** makes stored event times trustworthy.
> - **Series-III waveform times** now come from the instrument's own event
> record, which the unit sends inside its 5A stream. They used to be stamped
> with the monitoring-session start, hours off. The new time matches
> Blastware on every one of 1,320 report-paired waveforms, with no filename
> needed.
> - **Re-storing an event at its corrected time moves its row in place**,
> instead of duplicating it.
> - **Sub-minute histograms recorded with the mic off now decode** (#47, #49).
> - **Micromate `.h5` samples are on Thor's own scale** (#42).
> - **Series IV:** the live protocol is mapped (`docs/micromate_protocol_reference.md`)
> and has a read-only client.
>
> ⚠ The deploy owes a backfill and moves stored waveform times; see the
> changelog's *Migration*.
>
> **v0.33.0 (2026-11-01)** reads Series-III events from the file alone, and
> proves it.
> - **Fields now read from the event file** when no Blastware report comes with
> the event:
> - sample rate, record time, pre-trigger and the four notes (#44/#45)
> - the event type (#41)
> - a histogram's peak vector sum, which the unit stores per interval
> - the mic, at one count = 0.25 Pa (it read ~95× low in psi)
>
> This matters for every DL2 event from before 2025, and for SFM's own
> download and call-in paths, none of which have a report.
> - **The decode checker** (`scratch/check_s3_decode.py`) compares SFM's
> file-only decode with Blastware's `_XML.XML` event reports, field by field
> and sample by sample, for 70,042 DL2 events back to 2016:
> - every setup field, the notes and the event type match on every event
> - geophone samples are exact on 6,491 / 6,524 waveforms
> - the histogram vector sum matches on 69,919
>
> ⚠ The deploy owes a backfill; it does not move event times. See the
> changelog's *Migration*.
>
> **v0.34.0 (2026-11-04)** reaches Series-4 parity and reads most of
> Blastware's report from the event file alone.
> - **Series-4 parity:** one device door by serial for both series, with
> reads, downloads, start/stop, call-home and settings changes, each audited
> and read back. MiniMate request framing is fixed (#46).
> - **The file-only decode:** 47 of Blastware's 88 report fields match on
> every DL2 event, and 8 more on all but one or two.
> - Sensitive-range events are no longer 8× high.
> - Histograms decode correctly and carry Blastware's own times (#51).
> - Interval frequencies follow the sample rate (#50).
> - New from the file: the job number, serial, version, calibration,
> battery, trigger source and levels, interval detail, peak times and
> peak acceleration.
> - **Events are identified by unit + time + type.**
>
> ⚠ The deploy migrates the events table and owes an overnight backfill that
> moves every Series-3 histogram time by one second. See the changelog's
> *Migration*.
>
> **v0.35.0 (2026-11-16)** reaches 80 of Blastware's 88 report fields from the
> event file alone, and reads monitor logs.
> - **The file-only decode, groups D–F:** ZC frequency, displacement, times of
> peak, the sensor check, the Monitor Log line and over range, all from the
> unit's own records. A range-1 mic no longer reads 8× high.
> - **Monitor logs (.MLG):** SFM reads Blastware's `.MLG` files and keeps each
> unit's monitoring timeline, so it can answer "was unit X monitoring at T"
> for a shot report. See the `.MLG` endpoints below.
> - **An escaped checksum is the checksum, not data (#58).**
>
> ⚠ The deploy owes a backfill (about 8 hours on the NAS) and creates two
> empty tables. See the changelog's *Migration*.
> See [CHANGELOG.md](CHANGELOG.md) for full version history.
> **v0.15.0 (2026-05-07)** adds layered per-event storage (BW binary +
> raw 5A pickle + HDF5 + `.sfm.json` sidecar), a plot-ready
> `sfm.plot.v1` JSON shape with server-side ADC-to-physical-units
> conversion, and a BW-file importer for ingesting externally-produced
> events. See [CHANGELOG.md](CHANGELOG.md) for full version history.
---
@@ -137,26 +28,17 @@ over direct RS-232 or cellular modem (Sierra Wireless RV50 / RV55).
seismo-relay/
├── seismo_lab.py ← Main GUI (Bridge + Analyzer + Download + Console tabs)
│
├── minimateplus/ ← Series III (MiniMate Plus) client library
├── minimateplus/ ← MiniMate Plus client library
│ ├── transport.py ← SerialTransport, TcpTransport, SocketTransport
│ ├── protocol.py ← DLE frame layer, SUB command dispatch
│ ├── client.py ← High-level client (connect, get_events, delete_all_events, push_config, get_call_home_config, …)
│ ├── framing.py ← Frame builders, DLE codec, S3FrameParser
│ ├── models.py ← DeviceInfo, Event, ComplianceConfig, MonitorLogEntry, CallHomeConfig, …
│ ├── bw_ascii_report.py ← Parse BW per-event ASCII reports (.TXT sidecars)
│ ├── event_file_io.py ← Read BW binaries, write .sfm.json sidecars
│ └── blastware_file.py ← Write events to Blastware-compatible .AB0 files
│
├── micromate/ ← Series IV (Micromate / Thor) client library (NEW v0.19)
│ ├── models.py ← IdfEvent, IdfReport, IdfPeaks, IdfProjectInfo, IdfSensorCheck (mic in native dB(L))
│ ├── idf_ascii_report.py ← Parse Thor .IDFW.txt / .IDFH.txt event sidecars
│ ├── idf_file.py ← Binary codec for .IDFW + .IDFH (v0.21.0+)
│ └── idf_to_bw_report.py ← Adapter projecting Thor IDF into the BW report shape (v0.21.0+)
│
├── sfm/ ← SFM REST API server (FastAPI, port 8200)
│ ├── server.py ← Live device endpoints + DB query + ingest endpoints + caching
│ ├── database.py ← SeismoDb — SQLite persistence (events, monitor_log, ach_sessions)
│ ├── waveform_store.py ← On-disk store for BW + IDF event binaries + .sfm.json sidecars
│ ├── server.py ← Live device endpoints + DB query endpoints + caching
│ ├── database.py ← SeismoDb — SQLite persistence (events, monitor_log, ach_sessions, sessions table)
│ └── sfm_webapp.html ← Embedded web UI with Call Home config tab
│
├── bridges/
@@ -173,8 +55,7 @@ seismo-relay/
│ └── frame_db.py ← SQLite frame database
│
└── docs/
├── instantel_protocol_reference.md ← Series III protocol spec (the Rosetta Stone)
└── idf_protocol_reference.md ← Series IV (Thor IDF) format reference + codec RE plan
└── instantel_protocol_reference.md ← Reverse-engineered protocol spec
```
---
@@ -245,25 +126,10 @@ via a thread-safe `_LiveCache` (plain Python dict + `threading.Lock`):
| `POST` | `/device/monitor/start` | Sends SUB 0x96; immediately evicts status cache |
| `POST` | `/device/monitor/stop` | Sends SUB 0x97; immediately evicts status cache |
| `POST` | `/device/call_home` | Reads, patches specified fields, writes back to device |
| `GET` | `/device/settings` | Recording settings in the shared model, either series; serial required; never cached |
| `POST` | `/device/hangup` | Releases a held Series-4 line now; `{"hung_up": bool}` |
| `GET` | `/device/events?serial=` | Lists a unit's events, either series, each with an opaque `event_id` (`serial:key:timestamp`). A MiniMate list reads headers only (no bulk download), on the normal timeout, and gives `record_type: null` (its event record does not say waveform or histogram; not decoded yet). A lost walk reply fails the list rather than shortening it (a lost event-record reply still lists that event, without a timestamp) |
| `POST` | `/device/events/download?serial=&event_id=` | Downloads one event, checks it, and stores it in SFM's database; returns `db_event_id` (file at `GET /db/events/{db_event_id}/blastware_file`). A stale `event_id` (unit erased or wrapped since the list) gets **409** without downloading, for both series; an `event_id` from another unit gets **422**, before any I/O. An event already stored — by an earlier download, or by THOR's or Blastware's call-home watcher — returns its existing row and changes nothing (same `db_event_id`, `inserted: false`, `detail.already_stored: true`). The unit is busy for the whole download; other requests to it get 423 |
**Cache bypass** — All cached endpoints accept `?force=true` to skip the cache and
force a fresh read from the device.
**Serial-named requests (Series 3 and 4)** — `/device/info`, `/device/connect`,
`/device/monitor/status` and `/device/settings` accept `serial` (`UM...` = Series 4
Micromate, `BE...`/`BA...` = Series 3 MiniMate Plus) and return one shared model
for either series. Serial-named requests are **not cached** and ignore `force`.
Without `serial` the legacy Series-3 behaviour is unchanged. Any other `/device/*`
route given a `UM` serial answers **501** ("not supported for Series 4 yet"), and any
request that takes the legacy Series-3 path (no `serial`, or a `BE`/`BA` serial on a
route that does not take one) at an address holding a Series-4 line answers **409**
(use `POST /device/hangup` first). Series-4 lines are held open between requests, so
SFM must run a **single uvicorn worker**: locks and held lines are per process.
**Cache stats** — `GET /cache/stats` returns hit/miss counts and TTL info; `DELETE /cache/device`
clears the device cache immediately.
@@ -281,41 +147,10 @@ Query the SQLite database written by `ach_server.py`. All read-only except
| Method | URL | Description |
|--------|-----|-------------|
| `GET` | `/db/units` | All known serials with summary stats |
| `GET` | `/db/events` | Triggered events (filter by serial, date range, false_trigger). Response rows include `device_family` ("series3" / "series4") so clients dispatch on unit type without sniffing filenames. |
| `GET` | `/db/events` | Triggered events (filter by serial, date range, false_trigger) |
| `GET` | `/db/monitor_log` | Monitoring intervals |
| `GET` | `/db/sessions` | ACH call-home session history |
| `PATCH` | `/db/events/{id}/false_trigger?value=true` | Flag / unflag false triggers |
| `GET` | `/db/units/{serial}/timeline?from_dt=&to_dt=` | A unit's monitoring timeline from its `.MLG`s: sessions (how each ended, events, trigger level), gaps and what each means, clock steps, call-ins (delivered / no_file / nothing_new). Times are the unit's own clock. |
| `GET` | `/db/units/{serial}/monitoring_at?at=` | Was the unit monitoring at `at`: `monitoring` / `not_monitoring` / `unknown`, with the session or gap that says so and the records and file behind it. |
| `GET` | `/db/mlg_records?serial=&from_dt=&to_dt=` | A unit's raw `.MLG` records, oldest first |
| `GET` | `/db/mlg_files/{id}` | The original `.MLG`, byte for byte (for printing or opening in Blastware) |
### File ingest endpoints
Used by watcher daemons to push field-collected event files into the SFM DB
+ waveform store. Both accept multipart uploads of binary event files
optionally paired with their ASCII sidecar reports; both dedup by
`(serial, timestamp)` and UPSERT device-authoritative fields on re-import.
Since v0.32.0 a Series-III event re-stored at a corrected time is matched by
its Blastware filename and moved in place (see *Database* below).
| Method | URL | Description |
|--------|-----|-------------|
| `POST` | `/db/import/blastware_file` | Series III: `.AB0*` / `.N00` binaries + paired `_ASCII.TXT`. Source: `series3-watcher`. |
| `POST` | `/db/import/idf_file` | Series IV: `.IDFH` / `.IDFW` binaries + paired `.IDFW.txt` / `.IDFH.txt`. Source: `thor-watcher`. |
| `POST` | `/db/import/mlg_file` | Series III monitor logs (`.MLG`), with each file's modified time as a JSON form field `mtimes`. Each file stored once; a damaged file stores nothing. Source: `scripts/import_mlg_dir.py` today; `series3-watcher` does not forward `.MLG`s yet. |
### DB snapshot / restore endpoints
Back the "full snapshot bundle" prod→dev refresh Terra-View orchestrates
(Settings → Database). Snapshot/zip are read-only; restore is gated and
dev-only.
| Method | URL | Description |
|--------|-----|-------------|
| `GET` | `/db/snapshot` | WAL-safe point-in-time copy of `seismo_relay.db` via the SQLite online backup API. |
| `GET` | `/db/waveforms/recent.zip?n=…` | Zips the on-disk files (event file + `.h5` / sidecars) for the *n* most-recent events. |
| `POST` | `/db/restore` | Validate-first restore of an uploaded DB + waveforms; takes a WAL-safe pre-restore safety backup, path-traversal-guards the zip. Gated by `SFM_DB_RESTORE_ENABLED` (dormant → 404). |
---
@@ -378,93 +213,22 @@ not per individual event).
---
## micromate library
Series IV / Thor support, sibling to `minimateplus`. Currently scoped to
offline-file ingest from Thor's TXT exporter; live-device protocol is
deferred until the binary codec is cracked.
```python
from micromate import IdfEvent, parse_idf_report
# Parse a .IDFW.txt / .IDFH.txt sidecar (1014 example files round-trip cleanly)
text = open("UM11719_20231219162723.IDFW.txt").read()
report_dict = parse_idf_report(text) # permissive dict
# Wrap into a typed event using the device-native binary filename
event = IdfEvent.from_report(report_dict, "UM11719_20231219162723.IDFW")
event.serial # "UM11719"
event.kind # "Waveform" or "Histogram"
event.peaks.transverse_ips # 0.0251 (in/s, native unit)
event.peaks.mic_pspl_dbl # 99.4 (dB(L), Thor's native mic unit — NOT psi)
event.project_info.project # "UPMC Presby-Loc 3-Level1-1R Elevator Rm"
event.sensor_check.tran # True (passed self-check)
event.firmware_version # "Micromate ISEE 11.0AK"
event.calibration_text # "November 22, 2023 by Instantel"
# Bridge to the existing minimateplus.Event shape for the DB / sidecar paths
# (waveform_key is a 16-byte sha256 prefix when ingesting from a binary file)
bridged_event = event.to_minimateplus_event(waveform_key=b"\x00" * 16)
```
The binary codec (`.IDFW` / `.IDFH` event files themselves) is on the
roadmap — see [`docs/idf_protocol_reference.md`](docs/idf_protocol_reference.md)
for everything known so far, the two observed file signatures, and the
reverse-engineering plan. The `micromate/idf_file.py` stub is where
`read_idf_file()` will land.
---
## Database
`ach_server.py` and the file-ingest endpoints write to
`bridges/captures/seismo_relay.db` (SQLite, WAL mode) via the `SeismoDb`
persistence layer. The main tables, all unit-keyed by serial number:
`ach_server.py` writes to `bridges/captures/seismo_relay.db` (SQLite, WAL mode) using the
`SeismoDb` persistence layer. Four tables, all unit-keyed by serial number:
| Table | Key | Contents |
|-------|-----|----------|
| `ach_sessions` | UUID | Per-call-home audit record: serial, timestamp, peer IP, events_downloaded, monitor_entries, duration_seconds |
| `events` | UUID, UNIQUE(serial, timestamp) | Triggered events: timestamp, Tran/Vert/Long/VectorSum/Mic PPV, project/client/operator/sensor_location strings, sample_rate, record_type, false_trigger flag, **`device_family`** ("series3" / "series4"), `blastware_filename` (binary at-rest in `waveforms/`), sidecar references |
| `monitor_log` | UUID, UNIQUE(serial, start_time) | Monitoring intervals from live 0x0A reads (`ach_server.py` only): serial, waveform_key, start_time, stop_time, duration_seconds, geo_threshold_ips |
| `mlg_files` | UUID, UNIQUE(file_name, sha256) | One row per Blastware `.MLG` received (v0.35.0): serial, size, record count, empty flag, call-in flag, the file's modified time, where the original is kept, and the call it came from (`last_stop`, `no_file_stops`) |
| `mlg_records` | UUID, UNIQUE(serial, start, stop, flag word, trigger source) | One row per `.MLG` log record, stored once: start, stop (NULL = monitoring started), flag word, trigger source, Blastware's text and trigger level |
| `events` | UUID, UNIQUE(serial, waveform_key) | Triggered events: timestamp, Tran/Vert/Long/VectorSum/Mic PPV, project/client/operator/sensor_location strings, sample_rate, record_type, false_trigger flag |
| `monitor_log` | UUID, UNIQUE(serial, waveform_key) | Monitoring intervals: serial, waveform_key, start_time, stop_time, duration_seconds, geo_threshold_ips |
| `events.false_trigger` | Boolean flag | PATCH endpoint to mark/unmark false triggers for review |
**Deduplication is by `(serial, timestamp)`** — the device clock is the
stable natural key. Repeat call-homes or re-runs UPSERT the row in place,
refreshing every device-authoritative field (peaks, project strings,
sample_rate, file references) so the latest writer wins. `false_trigger`
and `device_family` are preserved across UPSERTs. Earlier versions used
`(serial, waveform_key)` for dedup, but the device's event-key counter
resets to `0x01110000` after every erase, so timestamps are the correct
dedup field. Migration handles the transition transparently on first
startup.
**Since v0.32.0**, `insert_events` also matches a row by its Blastware filename
(Blastware names only; a generic upload name like `imported.bw` says nothing):
- **A corrected time moves the row.** An event re-stored at a corrected time —
the v0.32.0 backfill, or a watcher re-forward — has its existing row moved in
place, keeping its id and review.
- **A taken second is refused.** If a different file already holds that second,
nothing is written.
- **An estimate never changes a row.** An event whose time is only an estimate
(no validated embedded event record; see Series-III reference §7.8.9) is still
stored, but its time never moves, merges into or duplicates a row.
Every refusal is logged as a warning.
**`device_family` (added v0.19.0)** discriminates Series III from Series
IV at the SQL level. Set by every import path; the UI dispatches on it
to render mic units correctly (Series III: psi → dBL conversion; Series
IV: native dBL passthrough). Existing rows are backfilled at first
startup of v0.19.0+ by sniffing the binary filename extension.
The on-disk waveform store lives at `bridges/captures/waveforms/<serial>/`
and holds the original event binaries (BW `.AB0*` / `.N00` for Series III,
`.IDFH` / `.IDFW` for Series IV) plus their `.sfm.json` review/metadata
sidecars. Series III events also produce `.a5.pkl` source-frame pickles
and `.h5` clean-waveform exports; Series IV doesn't yet (pending codec).
Deduplication is by `(serial, waveform_key)` — repeat call-homes or re-runs never
produce duplicate rows. Post-erase key reuse is handled automatically via the
high-water mark in `ach_state.json`. Key-based state tracking allows correct
handling of device erasures (external or post-download).
---
@@ -546,28 +310,18 @@ Use **com0com** or **VSPD** to create the virtual COM pair on Windows.
## Key Features
**Series III (MiniMate Plus) device support:**
- [x] Full read/write/erase pipelines over RS-232 or TCP/cellular
**Device support:**
- [x] Full read/write/erase pipelines
- [x] Compliance config (recording mode, sample rate, histogram interval, geo sensitivity, project strings)
- [x] Auto Call Home config (read/write ACH settings, dial string, time slots, retries)
- [x] Monitor control (start/stop, status polling, battery/memory)
- [x] Monitor log entries (continuous monitoring intervals without full waveform download)
- [x] Blastware file ingest at `/db/import/blastware_file` (paired with `series3-watcher`)
- [x] Blastware monitor logs (`.MLG`) at `/db/import/mlg_file`, and each unit's monitoring timeline (`/db/units/{serial}/timeline`, `/monitoring_at`) (v0.35.0)
**Series IV (Micromate / Thor) device support:**
- [x] Thor IDF file ingest at `/db/import/idf_file` (paired with `thor-watcher`, v0.18.0+)
- [x] Native `IdfEvent` / `IdfReport` typed models — mic in dB(L), full title strings, sensor self-check, calibration, firmware version
- [x] Parser verified against 1,014 paired `.txt` sidecars in `thor-watcher/example-data/`
- [x] Binary `.IDFW` / `.IDFH` codec — ✅ v0.21.0. IDFW reuses `decode_waveform_v2()` on the body at offset `0x0f1f` (87–99% sample fidelity on quiet events); IDFH has a dedicated segment-based decoder (all 859 corpus files decode, 181,071 intervals total). See `micromate/idf_file.py` + `docs/idf_protocol_reference.md`.
- [ ] Live-device protocol — pending codec
**Data persistence:**
- [x] SQLite database (`seismo_relay.db`) with `events`, `monitor_log`, `ach_sessions`, `device_commands`, `mlg_files` and `mlg_records` tables
- [x] Per-row `device_family` column ("series3" / "series4") for clean UI / unit-of-measurement dispatch (v0.19.0+)
- [x] Deduplication by `(serial, timestamp)` — natural key handles post-erase counter resets
- [x] UPSERT on re-import refreshes every device-authoritative field (peaks, project, sample_rate); preserves operator review state (`false_trigger`)
- [x] Post-erase key-reuse detection (tracks high-water mark in `ach_state.json`)
- [x] SQLite database (`seismo_relay.db`) with 4 tables: ach_sessions, events, monitor_log, plus false_trigger flag
- [x] Deduplication by waveform key (handles re-runs and repeat call-homes)
- [x] Post-erase key-reuse detection (tracks high-water mark)
- [x] Session state (`ach_state.json`) with downloaded keys and max key
**REST API:**
- [x] Live device endpoints with in-memory caching (`_LiveCache`)
@@ -575,7 +329,6 @@ Use **com0com** or **VSPD** to create the virtual COM pair on Windows.
- [x] DB query endpoints (units, events, monitor_log, sessions, false_trigger PATCH)
- [x] Call Home config read/write endpoints
- [x] Blastware file download endpoint (`/device/event/{index}/blastware_file`)
- [x] Import endpoints for both device families (`/db/import/blastware_file`, `/db/import/idf_file`)
**File output (v0.7+, byte-perfect as of v0.14.3):**
- [x] Blastware-compatible `.AB0` / `.G10` file generation (waveform + metadata)
@@ -603,148 +356,10 @@ Use **com0com** or **VSPD** to create the virtual COM pair on Windows.
## Roadmap (Future)
> **Where it stands *today*** — an honest per-capability maturity assessment,
> what to rely on, known issues, and the gap to a real tool:
> [`docs/sfm_tool_status.md`](docs/sfm_tool_status.md). This section covers
> where it is *going*.
### Strategic direction — where this is going
seismo-relay is being built as a **suite of cooperating components**
that together replace and improve on Blastware's role. Three logical
tiers:
1. **SFM** (device-side) — owns the active connection to a physical
unit. Today: `minimateplus/`, `/device/*` HTTP endpoints,
`seismo_lab.py`. Future: live Thor / Micromate support.
2. **SDM** (data-side) — owns the database, waveform store, ingest
pipelines, and the read-API that Terra-View consumes. Today this
code lives under `sfm/` for historical reasons; the role has
migrated and the eventual rename is on the long-tail cleanup list.
3. **Codec library** — pure data-interpretation: `minimateplus/*_codec.py`,
`bw_ascii_report.py`, `micromate/idf_*.py`. Used by both SFM and
SDM, depends on neither.
Terra-View is downstream of SDM for fleet listings, event detail, etc.
The long-term vision adds a **second link** from Terra-View → SFM for
direct device interaction (see below).
The codec work in this repo isn't trying to replace BW's network
layer — BW's ACH file forwarding and Thor's IDF call-home are
battle-tested. The value is in the receiving and processing side: turn
the stream of binary+ASCII pairs into something users can search,
filter, alert on, and report from.
### Terra-View ↔ SFM device control (the long-term vision)
Today Terra-View only reads from SDM (event listings, dashboards,
project reports). When a unit goes missing — operator notices in the
Terra-View dashboard — there's no way to *do* anything from the UI.
The path of least resistance is to RDP into a Windows box and open
Blastware, which defeats the purpose of having Terra-View.
Target experience:
- Operator notices a unit in Terra-View dashboard hasn't called in.
- Clicks unit detail → "Connect to Device" button.
- Terra-View opens an embedded view (modal or side-panel) that talks
to SFM's `/device/*` endpoints over the network.
- Live view: device clock, battery, memory, current monitor status.
- Actions: start/stop monitoring, push compliance config changes, pull
fresh events, run a sensor self-check, change call-home settings.
- Audit log: every connect / action recorded in SDM for the unit
history.
Implementation steps (concrete):
- [ ] **SFM authentication & authorization layer.** Today `/device/*`
endpoints are unauthenticated — anyone on the network can call
them. Need at minimum a token-based auth, ideally with a "who
can connect to which units" mapping. Hard prerequisite for
letting Terra-View users into the control surface.
- [ ] **Terra-View "Connect to Device" entry point** on the unit
detail page. Renders only when unit has connection info on file
and the user has permission.
- [ ] **Embedded live-monitor view** in Terra-View — equivalent to
`seismo_lab.py`'s Bridge tab, but in the browser. Polls SFM's
`/device/monitor/status` on an interval; sends start/stop via
`/device/monitor/{start,stop}`.
- [ ] **Action history** — every connect / push / action call records
a row in `unit_history`, viewable on the unit detail page.
- [ ] **Series IV live-device support in SFM** — currently `/device/*`
only supports MiniMate Plus. Blocks "Connect to Device" for
Thor units until done. Depends on Thor wire-protocol capture
and a `micromate/` parallel of the `minimateplus/` modules.
### High-impact (unblocks product features)
- [x] **Series III waveform body codec reverse-engineering.** ✅ The body codec is fully decoded (`minimateplus/waveform_codec.py`, `histogram_codec.py`), and verified per-sample against Blastware's own exports. Geophone samples are exact on all 6,524 DL2 waveforms against their `_XML.XML` reports, across 2016–2026 (`dev`; v0.33.0 had 6,491, before the geophone range was read from the file).
- [ ] **SFM produces everything Blastware reports, from the event file alone.**
**Why this matters:** until it's done, prod overlays Blastware's ASCII report onto SFM's decode wherever a report exists. That made SFM trustworthy from day one, but it is scaffolding: the goal is full function without Blastware.
The four-piece plan:
1. the decode checker ✅ v0.33.0
2. complete the file-only decode, one field group at a time, each proven by the checker
3. flip ingest so reports are kept only for checking (retire the overlay)
4. stop the watchers forwarding reports
**Done so far: 47 of 88 report fields match on every DL2 event.**
- In v0.33.0: setup fields, notes, event type, histogram PVS, mic.
- On `dev`:
- the geophone range
- the job number
- histograms that decoded wrongly
- the footer: no more day-late histograms; every waveform time exact
- serial, version, calibration, battery, trigger source and levels, stop mode, mic type
- histogram interval detail: frequencies (#50 fixed), per-interval PVS, interval size, stop
- histogram start, stop, interval and peak times (#51 fixed); events keyed unit + time + type
- A Blastware report's dB/psi is its PC's preference, not anything in the event file: a carve-out.
**Next:**
- the values Blastware computes itself: ZC frequency, acceleration, displacement, time of peak
- the sensor check results
- the monitor log
Design: `docs/superpowers/specs/2026-10-29-s3-decode-checker-design.md`. Status detail: CLAUDE.md "Where things stand".
- [x] **Series IV (Thor IDF) binary codec reverse-engineering.** ✅ v0.21.0 — `micromate/idf_file.read_idf_file()` decodes both IDFW (waveform body at offset `0x0f1f`, reusing `decode_waveform_v2()`; 87–99% sample fidelity on quiet events) and IDFH (dedicated segment-based decoder: all 859 corpus files decode, 181,071 intervals, peaks within ~1.8% of sidecar values). `WaveformStore.save_imported_idf` now also projects parsed Thor data into a `bw_report` block via `micromate/idf_to_bw_report.py` so Thor events render in the existing Event Report PDF pipeline without a separate renderer.
- [ ] **In-app waveform viewer accuracy.** Depends on Series III codec decode. Plot.v1 JSON pipeline + viewer skeleton already exist; will start showing real waveforms automatically once `_decode_a5_waveform` produces correct samples. Series IV waveforms come online when the IDF codec lands.
- [ ] **Series IV live-device support.** Once the IDF binary is decoded, extend `micromate/` with `transport.py` / `framing.py` / `protocol.py` / `client.py` mirroring the `minimateplus/` package layout — depends on capturing Thor's wire protocol (TCP / RS-232 captures TBD).
- [ ] **Terra-view integration** — seismo-relay router, unit detail page, VISON-style event listing.
- [ ] **Vibration summary reports** — highest legit PPV per project → Word doc (false-trigger filtering first).
### BW ASCII report parser enhancements (built in v0.16.0)
- [x] **PPV field misses on certain TXT formats.** ✅ v0.20.0 — root cause was the `OORANGE` (Out Of Range) saturation marker that BW writes when a channel exceeds its full-scale; `_parse_number()` returned None for the non-numeric value. Parser now substitutes `geo_range_ips` as a lower bound + sets `ppv_saturated` flag. All 5 prod events (T190LD5Q.LK0W, T438L713.RY0W, K557L3YM.OE0W, + 2 others) now parse cleanly.
- [x] **Histogram-specific structural fields.** ✅ v0.20.0 — `Histogram Start/Stop Time+Date`, `Number of Intervals`, `Interval Size`, per-channel `Peak Time` + `Peak Date`, and `Peak Vector Sum Date` all parse now. Land in the sidecar's `bw_report.histogram` block.
- [ ] **Histogram interval bin-table parsing.** Trailing 792-row table (per-interval Peak/Freq per channel + MicL) in histogram TXTs is unparsed. Probably too big for the sidecar JSON; may want a separate `.histogram.h5` companion file.
- [x] **`>100 Hz` value parsing.** ✅ v0.20.0 — parser now mirrors the OORANGE pattern: stores 100.0 on `zc_freq_hz` + sets `zc_freq_above_range` flag. PDF + both modals render `>100 Hz` instead of `—`.
### Ingestion gaps
- [ ] **Event importer (parked 2026-10-29).** A way to load a folder of event files from disk into SFM in bulk — a historical archive, a laptop's Blastware folder, a backup — without routing them through a watcher. It is one of the four ways events should reach SFM (watcher forward, upload from disk, SFM's own serial/modem download, SFM's future call-in server). Prompted by DL2's 2016–2024 backfill, which the watcher could only drip-feed at 500 events a pass.
- [ ] **MLG forwarding.** `series3-watcher` forwards event binaries + their `_ASCII.TXT` reports, but skips `.MLG` per-unit monitor log files entirely. Adding an `POST /db/import/mlg_file` endpoint + watcher scan path would populate `monitor_log` for non-ACH-routed units (coverage queries, "was this unit monitoring on date X" lookups).
- [ ] **0C-record raw bytes persistence in the sidecar.** Currently on branch `claude/codec-re-cBGNe` as commit `a187124`; cherry-pick if useful as a standalone fix. Preserves the 210-byte 0C record under `extensions.raw_records.waveform_record_b64` so future field-offset analysis (Peak Acceleration / Time of Peak / etc. — the fields BW computes client-side from samples) can run offline.
### Operational
- [ ] **`series3-watcher` file archive manager** — 90-day-old events moved to `<watch_folder>_archive/<year>/<month>/` subfolders. Plan drafted in `claude/codec-re-cBGNe`'s plan-mode session; awaiting a 5-minute test on whether Blastware UI walks subfolders before any code lands (determines layout: in-place subfolders vs sibling archive).
- [ ] **Compliance config encoder** — build raw write payloads from a `ComplianceConfig` object.
- [ ] **Modem manager** — push RV50/RV55 configs via Sierra Wireless API.
- [ ] **Call Home dial_string write support** (requires DLE escaping for embedded control characters).
- [ ] **Histogram mode recording support** (5A stream analysis for mode 0x03 — separate from histogram ASCII parsing above).
### Test coverage
- [ ] Verify 30-sec event download — body may exceed `0xFFFF` and force the device into a different `end_key` encoding (none of the 2/3/10-sec test cases hit this boundary).
- [ ] Histogram mode (0x03) write via SFM — confirmed working for Single Shot / Continuous / Histogram+Continuous; Histogram (0x03) needs a live test from a non-Histogram starting state.
### Lower-priority cleanups
- [ ] Compliance write anchor-9 cleanup — when changing recording_mode via SFM, a spurious `0x10` may persist after Histogram→other mode transitions. Doesn't affect device operation but differs from BW's byte-perfect output.
- [ ] Locate "Sensor Check" byte in compliance config (need capture with Disabled vs Before-monitoring).
- [ ] Call Home — map time slots 3/4 offsets; confirm `modem_power_relay_enabled`.
- [ ] RV55 DCD/DTR — newer RV55 firmware doesn't assert DCD by default; units don't resume monitoring after call-home disconnect (`--restart-monitoring` flag deferred).
- [ ] **NULL-timestamp duplicate-row dedup (#52).** A small handful of events (2 known on prod as of 2026-05-22) have `events.timestamp IS NULL` because the codec couldn't extract a timestamp from the binary footer. The `UNIQUE(serial, timestamp)` constraint doesn't fire on `NULL` (SQL semantics: `NULL ≠ NULL`), so every `--force` backfill INSERTs a new row instead of UPSERTing the existing one. Cleanup: a one-shot SQL query that keeps only the newest row per `(serial, blastware_filename)` and deletes the rest. Longer-term: extend the unique key to `(serial, COALESCE(timestamp, blastware_filename))` or reject inserts with NULL timestamp.
- [ ] **Histogram body sub-format with `byte[5] != 0`.** ~3 events on prod (`T190LD5Q.LD0H`, `O121L4L1.GU0H`) use a histogram body my walker doesn't recognize — the first block has `byte[5] = 0x01` or `0x07` instead of `0x00`, and the entire body lacks the `1e 0a 00 00` tail signature. Codec returns 0 valid blocks; their DB PVS comes from the bw_report ASCII overlay (which BW computed from the same binary, so the DB columns are correct). Only the `.h5` waveform plot is empty. Cracking the sub-format would unlock the plot. Needs binary+ASCII pairs from a few `byte[5]!=0` events; same RE approach as the K558 case.
- [ ] **Histogram body sub-format with `byte[5] == 0x00` but undecodable.** Observed 2026-05-28 on BE17353 (S353) events: `S353L4H2.FZ0H`, `S353L4H2.P00H`, `S353L4H3.7O0H`, `S353L4H3.E10H`. Body starts `00 00 00 01 0a 00 XX 00 ...` which LOOKS like a valid histogram block header (marker 0x000a at byte[4:6] ✓, byte[5]=0x00 normal-format ✓), but the walker finds zero data blocks across the whole body. Likely an extra header before the block stream OR a different tail signature than `1e 0a 00 00`. Smaller body lengths (1900-2100 bytes) suggest these may be short-recording histogram variants. Same operational impact as the byte[5]!=0 case: event ingests cleanly, DB peaks correct via bw_report overlay, only the chart is empty. Worth dumping a hex view of one body to diagnose.
- [ ] **Sensor-check waveform extraction from the BW binary.** BW's Event Report PDFs include a narrow panel on the right side of the waveform plot showing each channel's response to the sensor self-check signal (a damped sinusoid for geo, sawtooth-at-test-freq for mic). Our parser captures the test RESULTS (`test_freq_hz`, `test_ratio`, `test_amplitude_mv`, `test_results` pass/fail) and the PDF + modal display them as text — but BW's per-sample sensor-check waveform isn't accessible to us today. Two paths to add it: (a) RE the binary to find where the sensor-check samples are stored — could be a section before STRT, after the footer, or in a separate sub-record; protocol reference doesn't currently mention it. (b) If samples aren't in the binary, synthesize a representative waveform from the test parameters (damped sinusoid at `test_freq_hz` with damping from `test_ratio`). Path (a) is the honest answer; path (b) is decorative. Until either lands, the text-only sensor-check display in the report is fine.
- [ ] Verify 30-sec event download — body may exceed `0xFFFF` and force the device into a different `end_key` encoding (none of 2/3/10-sec test cases hit this boundary)
- [ ] Terra-view integration — seismo-relay router, unit detail page, VISON-style event listing
- [ ] Vibration summary reports — highest legit PPV per project → Word doc (false trigger filtering first)
- [ ] Compliance config encoder — build raw write payloads from a `ComplianceConfig` object
- [ ] Modem manager — push RV50/RV55 configs via Sierra Wireless API
- [ ] Histogram mode recording support (5A stream analysis for mode 0x03)
- [ ] Call Home dial_string write support (requires DLE escaping for embedded control characters)
-66
View File
@@ -1,66 +0,0 @@
# analysis/ — exploratory scripts for waveform-body RE
**These are scratch.** Run them, read them, copy them, but don't trust
them as documentation. When a finding is verified it gets promoted
to `minimateplus/waveform_codec.py` and `tests/test_waveform_codec.py`;
when it's wrong it stays here as a fossil.
Authoritative status lives in:
- `docs/waveform_codec_re_status.md` (current truth, working note)
- `minimateplus/waveform_codec.py` (verified implementation + docstring)
- `tests/test_waveform_codec.py` (regression locks against fixtures)
---
## Still useful
| File | What it does |
|---|---|
| `load_bundle.py` | Fixture loader. Parses BW binary + ASCII TXT into a `Bundle` dataclass with samples, metadata, body bytes. Used by most other scripts here. |
| `verify_tran.py` | Verifies `decode_tran_initial` against fixture ground truth across all events. Useful when you change the decoder and want a quick sanity check. |
| `inspect_5_11.py` | Inspects the 5-11-26 high-amplitude bundle's body structure, prints metadata, peaks, and block counts. |
| `walk_5_11.py` | Walks blocks for the 5-11-26 bundle and prints offset/tag/length/data. |
| `seg1_blocks.py` | Dumps all blocks in segment 1 of each event. The starting point for cracking multi-segment Tran continuation. |
| `full_tran.py` | Multi-segment Tran decoder attempt (broken — diverges at sample ~512). Useful as a starting scaffold for the next experiment. |
| `multi_segment.py` | Earlier multi-segment attempt with different segment-header consumption strategies. Records what didn't work. |
| `test_rle.py` | Tests `00 NN` interpretation as zero-RLE with different divisor values. Documents how the RLE rule was confirmed. |
## Superseded — keep for archaeology
| File | Superseded by |
|---|---|
| `walk_v2.py` … `walk_v5.py` | `walk_v6.py` and ultimately `minimateplus/waveform_codec.walk_body`. Each version represents one round of refinement. Don't read in isolation — read the diff between them to see what was learned. |
| `walk_chunks.py` | `walk_v6.py` / production walker |
| `decode_v1.py` | First naive decoder attempt. Wrong but readable. |
## Pure exploration — read if curious
| File | What it explored |
|---|---|
| `inspect_body.py` | Byte-frequency stats per event. Established that bytes 0x00 / 0x10 dominate. |
| `find_blocks.py` | Searched for repeating 2-byte tag patterns. |
| `find_signal_runs.py` | Searched for stretches of bytes that "look like a smooth signal" (small inter-byte deltas). Found the `20 NN` literal blocks. |
| `dump_head.py`, `dump_trailer.py`, `dump_around.py` | Hex dumpers at various body positions. |
| `compare_cd.py` | Byte-diff between event-c and event-d (same length, similar signal). Used to identify structural vs data bytes. |
| `brute_force.py` | Tested 96 combinations of channel-permutation × nibble-order × sign-convention × init-from-header on the quiet bundle. All failed because the quiet bundle had T[0]=T[1]=0, making the preamble undetectable. |
| `try_nibbles.py`, `try_layouts.py` | Earlier channel-interleaving hypotheses. All wrong. |
| `test_tran_continue.py` | Test of "Tran continues uninterrupted across `30 04` blocks" hypothesis. Disproven. |
---
## Adding new scripts
If you're picking up the codec work, feel free to add new scripts here.
Suggested conventions:
- Start the filename with what you're testing: `test_<hypothesis>.py`,
`verify_<piece>.py`, `inspect_<region>.py`.
- Print enough output that the reader can see exactly which events
match / diverge and where.
- When a finding is solid, move the verified logic to
`minimateplus/waveform_codec.py` and add a regression test in
`tests/test_waveform_codec.py` — don't leave the truth only in
this directory.
- If a script is fully superseded, leave it in place (don't delete) —
the fossil record is useful when re-evaluating hypotheses later.
-93
View File
@@ -1,93 +0,0 @@
"""Brute-force test channel permutations / nibble orders on event-d (simplest signal)."""
import sys
import itertools
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
from minimateplus.waveform_codec import walk_body
def s4(n):
return n if n < 8 else n - 16
def decode(body, channel_perm, nibble_order, sign_mode, init_from_header):
"""Try one decoder configuration on event-d. Returns first 8 cumulative samples per channel."""
blocks = walk_body(body)
# Initial values from bytes [4:7] if init_from_header else 0
if init_from_header:
init = [body[4] if body[4] < 128 else body[4] - 256,
body[5] if body[5] < 128 else body[5] - 256,
body[6] if body[6] < 128 else body[6] - 256,
0]
else:
init = [0, 0, 0, 0]
cur = list(init)
out = [[init[0]], [init[1]], [init[2]], [init[3]]] # sample 0 = init
nibble_idx = 0 # within delta stream; channel = channel_perm[nibble_idx % 4]
# Walk only the 10 NN data blocks
for blk in blocks:
if blk.tag_hi != 0x10:
continue
for byte in blk.data:
if nibble_order == 'high_first':
nib1, nib2 = (byte >> 4) & 0xF, byte & 0xF
else:
nib1, nib2 = byte & 0xF, (byte >> 4) & 0xF
for nib in (nib1, nib2):
if sign_mode == 'signed':
delta = s4(nib)
else:
delta = nib
ch = channel_perm[nibble_idx % 4]
cur[ch] += delta
if (nibble_idx + 1) % 4 == 0:
out[0].append(cur[0])
out[1].append(cur[1])
out[2].append(cur[2])
out[3].append(cur[3])
nibble_idx += 1
if len(out[0]) >= 16:
return out
return out
def best_match(pred, truth, n=10):
"""Sum of squared differences in first n samples."""
n = min(n, len(pred), len(truth))
return sum((pred[i] - truth[i])**2 for i in range(n))
def main():
b = load_bundle("event-d")
# truth in 16-count units
tr = {ch: [round(v * 200) for v in b.samples[ch]] for ch in ("Tran", "Vert", "Long")}
print("Truth event-d first 10 samples:")
for ch in ("Tran", "Vert", "Long"):
print(f" {ch}: {tr[ch][:10]}")
# Test 96 combinations
best = []
for perm in itertools.permutations([0, 1, 2, 3]):
for nibble_order in ('high_first', 'low_first'):
for sign in ('signed', 'unsigned'):
for init_h in (False, True):
decoded = decode(b.body, perm, nibble_order, sign, init_h)
# Score as TVL channel-sum
score = sum(
best_match(decoded[i], tr[ch], n=10)
for i, ch in enumerate(("Tran", "Vert", "Long"))
if i < 3
)
label = f"perm={perm} nib={nibble_order[:1]} sign={sign[:3]} init={init_h}"
best.append((score, label, decoded))
best.sort(key=lambda x: x[0])
print(f"\nTop 10 configurations:")
for s, lbl, dec in best[:10]:
print(f" score={s:>5} {lbl} T={dec[0][:8]} V={dec[1][:8]} L={dec[2][:8]}")
if __name__ == "__main__":
main()
-42
View File
@@ -1,42 +0,0 @@
"""Compare event-c and event-d (same N_samples) to find header vs data bytes."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def main():
bc = load_bundle("event-c")
bd = load_bundle("event-d")
# Compare prefixes
nc, nd = len(bc.body), len(bd.body)
n = min(nc, nd)
diffs = []
for i in range(n):
if bc.body[i] != bd.body[i]:
diffs.append(i)
print(f"event-c body={nc}, event-d body={nd}")
print(f"Total diffs (first {n}): {len(diffs)}")
# Show common prefix
same_prefix = 0
for i in range(n):
if bc.body[i] == bd.body[i]:
same_prefix += 1
else:
break
print(f"Common prefix length: {same_prefix}")
print(f"event-c prefix: {bc.body[:same_prefix].hex(' ')}")
# Look for runs of common bytes
print(f"\nFirst 32 diff positions: {diffs[:32]}")
# Show the "diff fingerprint" of the first 100 bytes
print(f"\n pos c d")
for i in range(0, 100):
marker = " " if bc.body[i] == bd.body[i] else "*"
bd_b = bd.body[i] if i < nd else None
print(f" {i:>3} {bc.body[i]:02x}{marker} {bd_b:02x}" if bd_b is not None else f" {i:>3} {bc.body[i]:02x}{marker}")
if __name__ == "__main__":
main()
-99
View File
@@ -1,99 +0,0 @@
"""
Decoder v1: nibble-pair signed deltas in 10 NN blocks, 4-channel round-robin.
"""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def s4(n):
return n if n < 8 else n - 16
def walk_blocks(body, start):
i = start
blocks = []
while i + 1 < len(body):
t0, t1 = body[i], body[i + 1]
if t0 == 0x10 and t1 % 4 == 0 and 0 < t1 <= 0xFC:
length = t1 // 2 + 2
data = bytes(body[i + 2 : i + length])
blocks.append(("10", t1, data))
i += length
elif t0 == 0x20 and t1 % 4 == 0 and 0 < t1 <= 0xFC:
length = t1 + 2
data = bytes(body[i + 2 : i + length])
blocks.append(("20", t1, data))
i += length
elif t0 == 0x00 and t1 % 4 == 0:
blocks.append(("00", t1, b""))
i += 2
elif t0 == 0x30 and t1 % 4 == 0 and 0 < t1 <= 0x10:
length = t1 * 4
data = bytes(body[i + 2 : i + length])
blocks.append(("30", t1, data))
i += length
elif t0 == 0x40 and t1 == 0x02:
length = 20
data = bytes(body[i + 2 : i + length])
blocks.append(("40", t1, data))
i += length
else:
blocks.append(("??", t0, bytes(body[i:i+8])))
break
return blocks
def decode_v1(body, start, n_samples):
"""Decode by accumulating nibble-pair deltas from all 10 NN blocks."""
blocks = walk_blocks(body, start)
# 4 channels: T, V, L, M
cur = [0, 0, 0, 0]
out = [[], [], [], []]
sample_index = 0 # how many sample-sets emitted
for typ, NN, data in blocks:
if typ == "10":
# 2 nibbles per byte, round-robin TVLM
for byte in data:
for nib in ((byte >> 4) & 0xF, byte & 0xF):
ch = sample_index % 4
cur[ch] += s4(nib)
out[ch].append(cur[ch])
sample_index = (sample_index + 1) // 4 * 4 + (sample_index + 1) % 4 # ?
sample_index += 1
# We emit per-nibble, but the structure is unclear
elif typ == "20":
# int8 absolute or delta?
for byte in data:
v = byte if byte < 128 else byte - 256
ch = sample_index % 4
cur[ch] = v # treat as absolute
out[ch].append(cur[ch])
sample_index += 1
return out
def main():
b = load_bundle("event-c")
body = b.body
truth_T = [round(v * 200) for v in b.samples["Tran"]]
truth_V = [round(v * 200) for v in b.samples["Vert"]]
truth_L = [round(v * 200) for v in b.samples["Long"]]
# Find start
for s in range(15):
if body[s] == 0x10 and body[s+1] % 4 == 0 and 0 < body[s+1] <= 0xFC:
start = s
break
blocks = walk_blocks(body, start)
# Print block-by-block what's in each
print(f"Total blocks: {len(blocks)}")
bytes_processed = 0
for typ, NN, data in blocks[:30]:
print(f" type={typ} NN=0x{NN:02x} data_len={len(data)} data_hex={data[:32].hex(' ')}{'...' if len(data) > 32 else ''}")
if __name__ == "__main__":
main()
-27
View File
@@ -1,27 +0,0 @@
"""Dump body bytes around a specific offset."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def dump_around(name: str, center: int, radius: int = 96):
b = load_bundle(name)
body = b.body
start = max(0, center - radius)
end = min(len(body), center + radius)
print(f"\n=== {name} body[{start}:{end}] (full body={len(body)}) ===")
for i in range(start, end, 32):
row = body[i:i+32]
marker = " <-- center" if i <= center < i+32 else ""
print(f" +{i:>5} {row.hex(' ')}{marker}")
def main():
# Look at the trailer transitions
trailer_starts = {"event-a": 7047, "event-b": 6475, "event-c": 4043, "event-d": 3941}
for name, off in trailer_starts.items():
dump_around(name, off, 96)
if __name__ == "__main__":
main()
-18
View File
@@ -1,18 +0,0 @@
"""Dump the START of each body in 32-byte rows."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def main():
for name in ("event-a", "event-c"):
b = load_bundle(name)
body = b.body
print(f"\n=== {name} body[0:512] (full body={len(body)}, samples={len(b.samples['Tran'])}) ===")
for i in range(0, min(512, len(body)), 32):
row = body[i:i+32]
print(f" +{i:>5} {row.hex(' ')}")
if __name__ == "__main__":
main()
-24
View File
@@ -1,24 +0,0 @@
"""Dump body bytes split into 32-byte rows starting from `start_offset`."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def dump(body: bytes, name: str, start: int, n_rows: int = 30):
print(f"\n=== {name} body[{start}:] (full body={len(body)}) ===")
end = min(start + 32 * n_rows, len(body))
for i in range(start, end, 32):
row = body[i:i+32]
print(f" +{i:>5} {row.hex(' ')}")
def main():
for name in ("event-a", "event-b", "event-c", "event-d"):
b = load_bundle(name)
# Print the LAST ~600 bytes of the body to see the tail structure
start = max(0, len(b.body) - 32 * 12)
dump(b.body, name, start, 12)
if __name__ == "__main__":
main()
-41
View File
@@ -1,41 +0,0 @@
"""Search for structural repetition in the body bytes."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def find_pattern_offsets(body: bytes, pattern: bytes, max_count=20):
out = []
i = 0
while True:
i = body.find(pattern, i)
if i < 0:
break
out.append(i)
i += 1
if len(out) >= max_count:
break
return out
def main():
for name in ("event-a", "event-b", "event-c", "event-d"):
b = load_bundle(name)
body = b.body
print(f"\n=== {name} (body={len(body)}, N_samples={len(b.samples['Tran'])}) ===")
# Try to find repeating substructures (look for 4-byte 0x10-prefixed markers)
for prefix in [b"\x10\x10", b"\x10\x04", b"\x10\x08", b"\x10\x0c", b"\x10\x18",
b"\x10\x14", b"\x10\x20", b"\x10\x40", b"\x10\x80", b"\x10\x00",
b"\x10\x01", b"\x10\x03", b"\x10\xf0", b"\xf1\x10", b"\x00\x10",
b"\x40\x02", b"\x20\x04", b"\x30\x04", b"\x30\x08", b"\x00\x1a"]:
offs = find_pattern_offsets(body, prefix, max_count=200)
if 1 <= len(offs) <= 1000:
# Print first 10 offsets
first = offs[:6]
last = offs[-3:]
print(f" '{prefix.hex()}' x{len(offs):>4} first={first} last={last}")
if __name__ == "__main__":
main()
-34
View File
@@ -1,34 +0,0 @@
"""Find body byte ranges that look like absolute int8 sample data (smooth waveform)."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def looks_like_smooth_int8(buf):
"""Convert bytes to int8 and check if successive deltas are small (waveform-like)."""
if len(buf) < 8:
return 0.0
vals = [b if b < 128 else b - 256 for b in buf]
diffs = [abs(vals[i+1] - vals[i]) for i in range(len(vals)-1)]
avg_diff = sum(diffs) / len(diffs)
return avg_diff
def main():
for name in ("event-a", "event-c"):
b = load_bundle(name)
body = b.body
# Scan with sliding window of 64 bytes; find segments where the bytes look like a smooth wave
win = 64
scores = []
for i in range(len(body) - win):
scores.append((i, looks_like_smooth_int8(body[i:i+win])))
# Lowest avg_diff means smoothest
scores.sort(key=lambda x: x[1])
print(f"\n=== {name} (body={len(body)}) — smoothest 10 windows ===")
for off, s in scores[:10]:
print(f" +{off:>5} avg_diff={s:.2f} bytes={body[off:off+24].hex(' ')}")
if __name__ == "__main__":
main()
-76
View File
@@ -1,76 +0,0 @@
"""Full Tran decoder: continues across segment headers using T_delta from header bytes [0:2]."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import _parse_txt
from minimateplus.waveform_codec import walk_body, find_data_start
def s4(n):
return n if n < 8 else n - 16
def i8(b):
return b if b < 128 else b - 256
def decode_full_tran(body):
if len(body) < 7 or body[0:3] != b"\x00\x02\x00":
return None
T0 = int.from_bytes(body[3:5], "big", signed=True)
T1 = int.from_bytes(body[5:7], "big", signed=True)
i = 7
while i + 1 < len(body) and body[i] not in (0x00, 0x10, 0x20, 0x30, 0x40):
i += 1
blocks = walk_body(body, i)
T = [T0, T1]
cur = T1
for blk in blocks:
if blk.tag_hi == 0x40:
# Segment header carries 2 T deltas (int16 BE each) at bytes [0:2] and [2:4]
if len(blk.data) >= 4:
delta1 = int.from_bytes(blk.data[0:2], "big", signed=True)
cur += delta1
T.append(cur)
delta2 = int.from_bytes(blk.data[2:4], "big", signed=True)
cur += delta2
T.append(cur)
elif blk.tag_hi == 0x10:
for byte in blk.data:
for nib in ((byte >> 4) & 0xF, byte & 0xF):
cur += s4(nib)
T.append(cur)
elif blk.tag_hi == 0x20:
for byte in blk.data:
cur += i8(byte)
T.append(cur)
elif blk.tag_hi == 0x00:
for _ in range(blk.tag_lo):
T.append(cur)
# 30 NN: skip for now
return T
def main():
for stem in ("M529LL1L.V70", "M529LL1L.JQ0", "M529LL1A.SP0", "M529LL1A.SS0", "M529LL1A.SV0"):
path = f"tests/fixtures/5-11-26/{stem}"
with open(path, "rb") as f:
body = f.read()[43:-26]
_, samples = _parse_txt(path + ".TXT")
truth_T = [round(v*200) for v in samples["Tran"]]
n_truth = len(truth_T)
decoded = decode_full_tran(body)
n = min(len(decoded), n_truth)
matches = sum(1 for i in range(n) if decoded[i] == truth_T[i])
div_at = -1
for i in range(n):
if decoded[i] != truth_T[i]:
div_at = i
break
print(f"{stem}: decoded={len(decoded)}, truth={n_truth}, matches={matches}/{n}, first div={div_at}")
if __name__ == "__main__":
main()
-50
View File
@@ -1,50 +0,0 @@
"""Quick inspection of the new high-amplitude events."""
import os, re, sys
sys.path.insert(0, ".")
from analysis.load_bundle import _parse_txt
from minimateplus.waveform_codec import walk_body, find_data_start
ROOT = "tests/fixtures/5-11-26"
def main():
for stem in ("M529LL1A.SP0", "M529LL1A.SS0", "M529LL1A.SV0"):
bin_path = os.path.join(ROOT, stem)
txt_path = bin_path + ".TXT"
with open(bin_path, "rb") as f:
raw = f.read()
body = raw[43:-26]
meta, samples = _parse_txt(txt_path)
n = len(samples["Tran"])
print(f"\n=== {stem} ===")
print(f" file={len(raw)}, body={len(body)}, N_samples={n}")
print(f" rectime={meta.get('Record Time')} pretrig={meta.get('Pre-trigger Length')}")
print(f" PPV(T,V,L)={meta.get('Tran PPV')} / {meta.get('Vert PPV')} / {meta.get('Long PPV')}")
# Show first few non-trivial samples
print(f" First 5 truth samples (in/s):")
for i in range(5):
print(f" T={samples['Tran'][i]:8.3f} V={samples['Vert'][i]:8.3f} "
f"L={samples['Long'][i]:8.3f} M={samples['MicL'][i]:8.3f}")
# Peak sample positions
for ch in ("Tran", "Vert", "Long"):
vals = samples[ch]
peak_i = max(range(n), key=lambda i: abs(vals[i]))
print(f" {ch}: peak {vals[peak_i]:.3f} at sample {peak_i} (t={peak_i/1024:.3f}s)")
# Body structure
start = find_data_start(body)
blocks = walk_body(body, start)
types = {}
for b in blocks:
types[b.tag_hi] = types.get(b.tag_hi, 0) + 1
print(f" body start={start}, total blocks walked: {len(blocks)}")
print(f" block tag counts: {types}")
# How far the walker got
if blocks:
last = blocks[-1]
walked = last.offset + last.length
print(f" walker stopped at offset {walked}/{len(body)} ({100*walked/len(body):.0f}%)")
if __name__ == "__main__":
main()
-23
View File
@@ -1,23 +0,0 @@
"""Print raw body hex + byte-distribution stats for one event."""
from collections import Counter
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def main():
for name in ("event-a", "event-b", "event-c", "event-d"):
b = load_bundle(name)
body = b.body
print(f"\n=== {name} ({len(body)} body bytes) ===")
print(f" STRT: {b.strt.hex()}")
print(f" body[0:64]: {body[:64].hex()}")
print(f" body[64:128]: {body[64:128].hex()}")
print(f" body[-32:]: {body[-32:].hex()}")
cnt = Counter(body)
print(f" top 16 bytes: {[(f'0x{k:02x}', f'{v/len(body):.2%}') for k,v in cnt.most_common(16)]}")
if __name__ == "__main__":
main()
-144
View File
@@ -1,144 +0,0 @@
"""
load_bundle.py — extract body bytes from BW binary + parse sample columns from TXT.
Used by the codec reverse-engineering scripts in this directory.
"""
from __future__ import annotations
import os
import re
from dataclasses import dataclass
BUNDLE_ROOT = os.path.join(
os.path.dirname(__file__), "..", "tests", "fixtures", "decode-re-5-8-26"
)
@dataclass
class Bundle:
name: str
bin_path: str
txt_path: str
bin: bytes
body: bytes # bytes between STRT (43) and footer (last 26)
strt: bytes # 21-byte STRT record
samples: dict # {"Tran": [...], "Vert": [...], "Long": [...], "MicL": [...]}
sample_rate: int
rectime_sec: float
pretrig_sec: float
geo_range_ips: float
ppv: dict # {"Tran": float, "Vert": float, "Long": float}
mic_pspl: float
serial: str
def _parse_txt(path: str) -> dict:
with open(path, "r", encoding="utf-8", errors="replace") as f:
text = f.read()
meta = {}
samples = {"Tran": [], "Vert": [], "Long": [], "MicL": []}
# Find header line that starts the columns ("Tran Vert Long MicL").
# Then every line after is sample data (4 tab-separated floats).
lines = text.splitlines()
header_idx = None
for i, line in enumerate(lines):
if "Tran" in line and "Vert" in line and "Long" in line and "MicL" in line:
# The columns header. Sample lines start a few lines later.
header_idx = i
break
if header_idx is None:
raise ValueError(f"no Tran/Vert/Long/MicL header in {path}")
# Parse meta — quoted lines with "Field : value"
for line in lines[:header_idx]:
m = re.match(r'^"([^"]+)\s*:\s*([^"]*)"', line.strip())
if m:
k, v = m.group(1).strip(), m.group(2).strip()
meta[k] = v
# Parse samples
for line in lines[header_idx + 1 :]:
line = line.strip()
if not line:
continue
parts = re.split(r"\s+", line)
if len(parts) < 4:
continue
try:
t = float(parts[0])
v = float(parts[1])
l = float(parts[2])
m = float(parts[3])
except ValueError:
continue
samples["Tran"].append(t)
samples["Vert"].append(v)
samples["Long"].append(l)
samples["MicL"].append(m)
return meta, samples
def load_bundle(name: str) -> Bundle:
folder = os.path.join(BUNDLE_ROOT, name)
files = os.listdir(folder)
bin_name = next(f for f in files if not f.endswith(".TXT"))
txt_name = next(f for f in files if f.endswith(".TXT"))
bin_path = os.path.join(folder, bin_name)
txt_path = os.path.join(folder, txt_name)
with open(bin_path, "rb") as f:
binary = f.read()
# Header is 22 bytes; STRT at [22:43]; footer at last 26 bytes.
strt = binary[22:43]
body = binary[43:-26]
meta, samples = _parse_txt(txt_path)
sample_rate = int(re.search(r"(\d+)", meta.get("Sample Rate", "1024")).group(1))
rectime_sec = float(re.search(r"([\d.]+)", meta.get("Record Time", "3.0")).group(1))
pretrig_sec = float(re.search(r"-?[\d.]+", meta.get("Pre-trigger Length", "0")).group(0))
geo_range_ips = float(re.search(r"([\d.]+)", meta.get("Geo Range", "10.0")).group(1))
serial = meta.get("Serial Number", "").strip()
def _f(s):
return float(re.search(r"-?[\d.]+", s).group(0))
ppv = {
"Tran": _f(meta.get("Tran PPV", "0")),
"Vert": _f(meta.get("Vert PPV", "0")),
"Long": _f(meta.get("Long PPV", "0")),
}
mic_pspl = _f(meta.get("MicL PSPL", "0"))
return Bundle(
name=name,
bin_path=bin_path,
txt_path=txt_path,
bin=binary,
body=body,
strt=strt,
samples=samples,
sample_rate=sample_rate,
rectime_sec=rectime_sec,
pretrig_sec=pretrig_sec,
geo_range_ips=geo_range_ips,
ppv=ppv,
mic_pspl=mic_pspl,
serial=serial,
)
if __name__ == "__main__":
for name in ("event-a", "event-b", "event-c", "event-d"):
b = load_bundle(name)
n = len(b.samples["Tran"])
print(f"{name}: body={len(b.body):>6} N_samples={n} rate={b.sample_rate} "
f"rectime={b.rectime_sec} pretrig={b.pretrig_sec} range={b.geo_range_ips} "
f"PPV(T,V,L)={b.ppv['Tran']:.3f},{b.ppv['Vert']:.3f},{b.ppv['Long']:.3f} "
f"MicL={b.mic_pspl}")
-81
View File
@@ -1,81 +0,0 @@
"""Decode Tran across multiple segments by resetting at 40 02 headers."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import _parse_txt
from minimateplus.waveform_codec import walk_body, find_data_start
def s4(n):
return n if n < 8 else n - 16
def i8(b):
return b if b < 128 else b - 256
def decode_full_tran(body):
"""Decode all Tran samples in the body, walking through segments."""
if len(body) < 7 or body[0:3] != b"\x00\x02\x00":
return None
T0 = int.from_bytes(body[3:5], "big", signed=True)
T1 = int.from_bytes(body[5:7], "big", signed=True)
# Locate first tag
i = 7
while i + 1 < len(body) and body[i] not in (0x00, 0x10, 0x20, 0x30, 0x40):
i += 1
blocks = walk_body(body, i)
T = [T0, T1]
cur = T1
for bi, blk in enumerate(blocks):
if blk.tag_hi == 0x40:
# Segment header — try interpreting bytes [0:2] as new T anchor
if len(blk.data) >= 2:
new_anchor = int.from_bytes(blk.data[0:2], "big", signed=True)
# The next sample IS this anchor value, NOT a delta from cur.
T.append(new_anchor)
cur = new_anchor
elif blk.tag_hi == 0x10:
for byte in blk.data:
for nib in ((byte >> 4) & 0xF, byte & 0xF):
cur += s4(nib)
T.append(cur)
elif blk.tag_hi == 0x20:
for byte in blk.data:
cur += i8(byte)
T.append(cur)
elif blk.tag_hi == 0x00:
# RLE: append NN zero deltas
for _ in range(blk.tag_lo):
T.append(cur)
# 30 NN: skip
return T
def main():
for stem in ("M529LL1L.V70", "M529LL1L.JQ0", "M529LL1A.SP0", "M529LL1A.SS0", "M529LL1A.SV0"):
path = f"tests/fixtures/5-11-26/{stem}"
with open(path, "rb") as f:
body = f.read()[43:-26]
_, samples = _parse_txt(path + ".TXT")
truth_T = [round(v*200) for v in samples["Tran"]]
n_truth = len(truth_T)
decoded = decode_full_tran(body)
n = min(len(decoded), n_truth)
matches = sum(1 for i in range(n) if decoded[i] == truth_T[i])
# Find first divergence
div_at = -1
for i in range(n):
if decoded[i] != truth_T[i]:
div_at = i
break
print(f"{stem}: decoded={len(decoded)}, truth={n_truth}, matches={matches}/{n}, first div={div_at}")
if div_at >= 0 and div_at < 30:
print(f" truth around div [{max(0,div_at-3)}:{div_at+8}]: {truth_T[max(0,div_at-3):div_at+8]}")
print(f" pred around div [{max(0,div_at-3)}:{div_at+8}]: {decoded[max(0,div_at-3):div_at+8]}")
if __name__ == "__main__":
main()
-28
View File
@@ -1,28 +0,0 @@
"""Dump all blocks in segment 1 of each event with their data."""
import sys
sys.path.insert(0, ".")
from minimateplus.waveform_codec import walk_body, find_data_start
def main():
for stem in ("M529LL1A.SP0", "M529LL1L.JQ0", "M529LL1L.V70"):
path = f"tests/fixtures/5-11-26/{stem}"
with open(path, "rb") as f:
body = f.read()[43:-26]
blocks = walk_body(body, find_data_start(body))
# Find segment 1 (between first and second 40 02)
seg40_indices = [i for i, b in enumerate(blocks) if b.tag_hi == 0x40]
if len(seg40_indices) < 2:
print(f"\n{stem}: only {len(seg40_indices)} segment headers found")
seg1_blocks = blocks[seg40_indices[0]:] if seg40_indices else []
else:
seg1_blocks = blocks[seg40_indices[0]:seg40_indices[1]+1]
print(f"\n=== {stem} segment 1 ({len(seg1_blocks)} blocks) ===")
for b in seg1_blocks[:25]:
tag = f"{b.tag_hi:02x}{b.tag_lo:02x}"
print(f" off={b.offset:>5} {tag} NN=0x{b.tag_lo:02x}({b.tag_lo:>3}) len={b.length:>3} data={b.data[:16].hex(' ')}{'...' if len(b.data)>16 else ''}")
if __name__ == "__main__":
main()
-195
View File
@@ -1,195 +0,0 @@
"""Test 12-bit signed packed deltas hypothesis for 30 NN blocks across all loud events.
For each 30 NN block in each event, identify what samples it should cover
(based on the cumulative delta count up to that point) and compare the
truth deltas against various 12-bit packing schemes.
"""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import _parse_txt
from minimateplus.waveform_codec import walk_body, find_data_start
CHANNEL_ORDER = ["Vert", "Long", "MicL", "Tran"] # rotation after initial T
def s12(v):
"""Sign-extend a 12-bit unsigned value to signed int."""
return v if v < 0x800 else v - 0x1000
def unpack_12bit_be(data):
"""4 deltas in 6 bytes, BE order: byte[0:1.5], byte[1.5:3], byte[3:4.5], byte[4.5:6]."""
# bits 0..47 (MSB-first), split into 4 × 12-bit
val = int.from_bytes(data, "big")
out = []
for i in range(4):
d = (val >> (12 * (3 - i))) & 0xFFF
out.append(s12(d))
return out
def unpack_12bit_le(data):
"""4 deltas in 6 bytes, LE order: bytes packed as 2 × 24-bit groups."""
out = []
# First 3 bytes contain 2 deltas
b0, b1, b2 = data[0], data[1], data[2]
d0 = b0 | ((b1 & 0x0F) << 8)
d1 = (b1 >> 4) | (b2 << 4)
out.append(s12(d0))
out.append(s12(d1))
# Next 3 bytes contain 2 more deltas
b3, b4, b5 = data[3], data[4], data[5]
d2 = b3 | ((b4 & 0x0F) << 8)
d3 = (b4 >> 4) | (b5 << 4)
out.append(s12(d2))
out.append(s12(d3))
return out
def unpack_12bit_be_per_triplet(data):
"""4 deltas as 2 triplets of (high4, low8) BE within each 3-byte group."""
out = []
b0, b1, b2 = data[0], data[1], data[2]
d0 = (b0 << 4) | (b1 >> 4)
d1 = ((b1 & 0x0F) << 8) | b2
out.append(s12(d0))
out.append(s12(d1))
b3, b4, b5 = data[3], data[4], data[5]
d2 = (b3 << 4) | (b4 >> 4)
d3 = ((b4 & 0x0F) << 8) | b5
out.append(s12(d2))
out.append(s12(d3))
return out
def truth_deltas_for_block(blocks, block_idx, event_truth, channel):
"""For a 30 NN block at block_idx, determine which samples it covers and
return the truth deltas for those samples.
Walks through all blocks before block_idx (within the same segment) and
counts how many deltas have been emitted for *channel*, starting from the
segment's anchor pair.
"""
# Find the segment header that contains this block.
seg_header_idx = None
for j in range(block_idx, -1, -1):
if blocks[j].tag_hi == 0x40:
seg_header_idx = j
break
if seg_header_idx is None:
# block is in the initial T segment; samples count from sample 2.
first_sample_in_segment = 2
else:
# Anchor pair covers samples [N, N+1] for some N. Subsequent deltas
# are samples [N+2, N+2+1, ...]. We don't actually need to know N
# for this test — just the relative position within the segment.
first_sample_in_segment = 2 # anchor=0,1; deltas start at 2
# Count deltas from segment-data start to block_idx.
delta_count = 0
start_block = seg_header_idx + 1 if seg_header_idx is not None else 0
for j in range(start_block, block_idx):
blk = blocks[j]
if blk.tag_hi == 0x10:
delta_count += blk.tag_lo # NN nibbles = NN deltas
elif blk.tag_hi == 0x20:
delta_count += blk.tag_lo # NN int8 deltas
elif blk.tag_hi == 0x00:
delta_count += blk.tag_lo # RLE zero deltas
# Now the 30 NN block carries NN deltas.
nn = blocks[block_idx].tag_lo
# First sample affected: segment first_sample + delta_count.
# But we ALSO need to know which segment this is, since the segment maps
# to a specific channel and a specific starting absolute sample index.
return first_sample_in_segment + delta_count, nn
def main():
for stem in ("M529LL1A.SP0", "M529LL1L.JQ0", "M529LL1L.V70",
"M529LL1A.SS0", "M529LL1A.SV0"):
path = f"tests/fixtures/5-11-26/{stem}"
with open(path, "rb") as f:
body = f.read()[43:-26]
_, samples = _parse_txt(path + ".TXT")
blocks = walk_body(body, find_data_start(body))
seg_idx = [i for i, b in enumerate(blocks) if b.tag_hi == 0x40]
# Find all 30 NN blocks in DATA section (not trailer).
thirty_blocks = []
for bi, b in enumerate(blocks):
if b.tag_hi != 0x30:
continue
# Determine which segment this is in
seg_num = None
for k, hi in enumerate(seg_idx):
next_hi = seg_idx[k + 1] if k + 1 < len(seg_idx) else len(blocks)
if hi < bi < next_hi:
seg_num = k
break
if seg_num is None and seg_idx and bi < seg_idx[0]:
seg_num = -1 # initial T segment
thirty_blocks.append((bi, b, seg_num))
if not thirty_blocks:
continue
print(f"\n=== {stem} ===")
for bi, b, seg_num in thirty_blocks:
# Channel for this segment
if seg_num == -1:
channel = "Tran"
seg_label = "initial T"
else:
channel = CHANNEL_ORDER[seg_num % 4]
seg_label = f"seg {seg_num}"
# Count deltas before this block within the same segment.
seg_header_idx = seg_idx[seg_num] if seg_num >= 0 else -1
start_block = seg_header_idx + 1 if seg_header_idx >= 0 else 0
delta_count = 0
for j in range(start_block, bi):
blk = blocks[j]
if blk.tag_hi in (0x10, 0x20, 0x00):
delta_count += blk.tag_lo
# First sample this 30 NN block affects (within the segment)
# = anchor positions + delta_count + 2 (since anchor pair was samples 0,1)
# But the segment's first absolute sample index in the channel is
# (seg_num // 4) * 512 (approximately) if segment 0 is the first V seg.
cycle = (seg_num // 4) if seg_num >= 0 else 0
base = cycle * 512 + 2 # +2 for anchor pair
sample_idx = base + delta_count
truth_ch = [round(v * 200) for v in samples[channel]]
nn = b.tag_lo
if sample_idx + nn >= len(truth_ch):
print(f" block @ {b.offset} ({seg_label} {channel}): out of truth range")
continue
# Get the previous sample so we can compute truth deltas
if sample_idx == 0:
prev = 0
else:
prev = truth_ch[sample_idx - 1]
truth_deltas = []
for k in range(nn):
truth_deltas.append(truth_ch[sample_idx + k] - (prev if k == 0 else truth_ch[sample_idx + k - 1]))
# Try each packing
schemes = [
("12-bit BE contiguous", unpack_12bit_be(b.data)),
("12-bit LE per-triplet", unpack_12bit_le(b.data)),
("12-bit BE per-triplet", unpack_12bit_be_per_triplet(b.data)),
]
print(f" block @ {b.offset:>5} ({seg_label} {channel}, samples {sample_idx}..{sample_idx+nn-1}):")
print(f" data: {b.data.hex(' ')}")
print(f" truth: {truth_deltas}")
for name, pred in schemes:
match = "✓" if pred == truth_deltas else " "
n_match = sum(1 for x, y in zip(pred, truth_deltas) if x == y)
print(f" {match}{n_match}/4 {name}: {pred}")
if __name__ == "__main__":
main()
-132
View File
@@ -1,132 +0,0 @@
"""Test the '30 NN data = high-nibbles + int8 low-bytes' hypothesis.
Layout for `30 04` (6 data bytes, 4 deltas):
bytes [0:2] = 16 bits = 4 × 4-bit high-nibbles (MSB first)
bytes [2:6] = 4 × int8 low bytes
Each delta = 12-bit signed = sign-extend((high_nibble << 8) | low_byte)
"""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import _parse_txt
from minimateplus.waveform_codec import walk_body, find_data_start
def s4(n):
return n if n < 8 else n - 16
def i8(b):
return b if b < 128 else b - 256
def sign_extend_12(v):
return v if v < 0x800 else v - 0x1000
def decode_30nn(data):
"""4 × 12-bit signed deltas (high nibble + low byte).
bytes[0:2] hold the 4 high nibbles (MSB first); bytes[2:6] hold the low bytes.
"""
if len(data) < 6:
return []
# Read high nibbles from bytes 0-1 (4 nibbles MSB-first)
high_word = (data[0] << 8) | data[1]
high_nibbles = [
(high_word >> 12) & 0xF,
(high_word >> 8) & 0xF,
(high_word >> 4) & 0xF,
high_word & 0xF,
]
out = []
for i in range(4):
v = (high_nibbles[i] << 8) | data[2 + i]
out.append(sign_extend_12(v))
return out
def simulate_up_to(blocks, target_block_idx, t_preamble):
"""Run decoder up to block_idx; return per-channel sample lists.
NOW with 30 NN decoded too."""
out = {"Tran": [], "Vert": [], "Long": [], "MicL": []}
out["Tran"].extend(t_preamble)
cur = {"Tran": t_preamble[-1], "Vert": None, "Long": None, "MicL": None}
rotation = ["Vert", "Long", "MicL", "Tran"]
current_channel = "Tran"
seg_counter = -1
for j in range(target_block_idx):
blk = blocks[j]
if blk.tag_hi == 0x40:
seg_counter += 1
prev = "Tran" if seg_counter == 0 else rotation[(seg_counter - 1) % 4]
new_ch = rotation[seg_counter % 4]
if cur[prev] is not None:
d0 = int.from_bytes(blk.data[0:2], "big", signed=True)
d1 = int.from_bytes(blk.data[2:4], "big", signed=True)
cur[prev] += d0; out[prev].append(cur[prev])
cur[prev] += d1; out[prev].append(cur[prev])
c0 = int.from_bytes(blk.data[14:16], "big", signed=True)
c1 = int.from_bytes(blk.data[16:18], "big", signed=True)
out[new_ch].extend([c0, c1])
cur[new_ch] = c1
current_channel = new_ch
elif blk.tag_hi == 0x10:
for byte in blk.data:
for nib in ((byte >> 4) & 0xF, byte & 0xF):
cur[current_channel] += s4(nib)
out[current_channel].append(cur[current_channel])
elif blk.tag_hi == 0x20:
for byte in blk.data:
cur[current_channel] += i8(byte)
out[current_channel].append(cur[current_channel])
elif blk.tag_hi == 0x00:
for _ in range(blk.tag_lo):
out[current_channel].append(cur[current_channel])
elif blk.tag_hi == 0x30:
# NEW: decode 30 NN
deltas = decode_30nn(blk.data)
for d in deltas:
cur[current_channel] += d
out[current_channel].append(cur[current_channel])
return out, current_channel
def main():
for stem in ("M529LL1A.SP0", "M529LL1L.JQ0", "M529LL1L.V70",
"M529LL1A.SS0", "M529LL1A.SV0"):
path = f"tests/fixtures/5-11-26/{stem}"
with open(path, "rb") as f:
body = f.read()[43:-26]
_, samples = _parse_txt(path + ".TXT")
blocks = walk_body(body, find_data_start(body))
t0 = int.from_bytes(body[3:5], "big", signed=True)
t1 = int.from_bytes(body[5:7], "big", signed=True)
thirty_blocks = [(j, b) for j, b in enumerate(blocks) if b.tag_hi == 0x30]
if not thirty_blocks:
continue
print(f"\n=== {stem} ===")
for j, blk in thirty_blocks:
pred, ch = simulate_up_to(blocks, j, [t0, t1])
cur_before = pred[ch][-1]
truth = [round(v * 200) for v in samples[ch]]
n_pred = len(pred[ch])
nn = blk.tag_lo
if n_pred + nn > len(truth):
continue
# Decode this 30 NN block with hypothesis
pred_deltas = decode_30nn(blk.data)
# Compute truth deltas relative to cur_before
truth_deltas = []
prev = cur_before
for k in range(nn):
truth_deltas.append(truth[n_pred + k] - prev)
prev = truth[n_pred + k]
n_match = sum(1 for a, b in zip(pred_deltas, truth_deltas) if a == b)
tag = "✓" if pred_deltas == truth_deltas else " "
print(f" block @ {blk.offset:>5} (chan={ch}, NN={nn}):")
print(f" data: {blk.data.hex(' ')}")
print(f" truth: {truth_deltas}")
print(f" pred: {pred_deltas} {tag}{n_match}/{nn}")
if __name__ == "__main__":
main()
-141
View File
@@ -1,141 +0,0 @@
"""Test 30 NN packing by running the real decoder up to each 30 NN block,
recording how many samples have been produced for each channel at that point,
then checking truth deltas immediately after."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import _parse_txt
from minimateplus.waveform_codec import walk_body, find_data_start
def s4(n):
return n if n < 8 else n - 16
def i8(b):
return b if b < 128 else b - 256
def s12(v):
return v if v < 0x800 else v - 0x1000
def unpack_12bit_be_contiguous(data):
out = []
val = int.from_bytes(data, "big")
n = len(data) * 8 // 12
for i in range(n):
d = (val >> (12 * (n - 1 - i))) & 0xFFF
out.append(s12(d))
return out
def unpack_12bit_per_triplet_be(data):
out = []
for i in range(0, len(data), 3):
if i + 2 >= len(data):
break
b0, b1, b2 = data[i], data[i + 1], data[i + 2]
d0 = (b0 << 4) | (b1 >> 4)
d1 = ((b1 & 0x0F) << 8) | b2
out.append(s12(d0))
out.append(s12(d1))
return out
def simulate_up_to(blocks, target_block_idx, t_preamble):
"""Run the decoder up to block_idx; return per-channel sample lists."""
out = {"Tran": [], "Vert": [], "Long": [], "MicL": []}
out["Tran"].extend(t_preamble)
cur = {"Tran": t_preamble[-1], "Vert": None, "Long": None, "MicL": None}
rotation = ["Vert", "Long", "MicL", "Tran"]
seg_idx = [j for j, b in enumerate(blocks) if b.tag_hi == 0x40]
# Determine which channel we're CURRENTLY decoding into
current_channel = "Tran"
seg_counter = -1 # incremented at each 40 02
for j in range(target_block_idx):
blk = blocks[j]
if blk.tag_hi == 0x40:
# Switch: extend prev channel, set up new channel
seg_counter += 1
prev = "Tran" if seg_counter == 0 else rotation[(seg_counter - 1) % 4]
new_ch = rotation[seg_counter % 4]
if cur[prev] is not None:
d0 = int.from_bytes(blk.data[0:2], "big", signed=True)
d1 = int.from_bytes(blk.data[2:4], "big", signed=True)
cur[prev] += d0; out[prev].append(cur[prev])
cur[prev] += d1; out[prev].append(cur[prev])
c0 = int.from_bytes(blk.data[14:16], "big", signed=True)
c1 = int.from_bytes(blk.data[16:18], "big", signed=True)
out[new_ch].extend([c0, c1])
cur[new_ch] = c1
current_channel = new_ch
elif blk.tag_hi == 0x10:
for byte in blk.data:
for nib in ((byte >> 4) & 0xF, byte & 0xF):
cur[current_channel] += s4(nib)
out[current_channel].append(cur[current_channel])
elif blk.tag_hi == 0x20:
for byte in blk.data:
cur[current_channel] += i8(byte)
out[current_channel].append(cur[current_channel])
elif blk.tag_hi == 0x00:
for _ in range(blk.tag_lo):
out[current_channel].append(cur[current_channel])
elif blk.tag_hi == 0x30:
# Skip for now — we want to know what comes next
pass
return out, current_channel
def main():
for stem in ("M529LL1A.SP0", "M529LL1L.JQ0", "M529LL1L.V70",
"M529LL1A.SS0", "M529LL1A.SV0"):
path = f"tests/fixtures/5-11-26/{stem}"
with open(path, "rb") as f:
body = f.read()[43:-26]
_, samples = _parse_txt(path + ".TXT")
blocks = walk_body(body, find_data_start(body))
t0 = int.from_bytes(body[3:5], "big", signed=True)
t1 = int.from_bytes(body[5:7], "big", signed=True)
# Find all 30 NN blocks in data section
thirty_blocks = [(j, b) for j, b in enumerate(blocks) if b.tag_hi == 0x30]
if not thirty_blocks:
continue
print(f"\n=== {stem} ===")
for j, blk in thirty_blocks:
pred, ch = simulate_up_to(blocks, j, [t0, t1])
n_pred = len(pred[ch])
# The 30 NN block carries NN deltas for channel `ch` starting at sample n_pred
truth = [round(v * 200) for v in samples[ch]]
if n_pred >= len(truth):
continue
# Truth deltas: truth[n_pred] - cur, truth[n_pred+1] - truth[n_pred], ...
cur_val = pred[ch][-1]
nn = blk.tag_lo
truth_deltas = []
prev = cur_val
for k in range(min(nn, len(truth) - n_pred)):
truth_deltas.append(truth[n_pred + k] - prev)
prev = truth[n_pred + k]
print(f" block @ {blk.offset:>5} (chan={ch}, after sample {n_pred-1}, "
f"NN={nn}, last_val={cur_val}):")
print(f" data: {blk.data.hex(' ')}")
print(f" truth: {truth_deltas}")
schemes = [
("12-bit BE contiguous", unpack_12bit_be_contiguous(blk.data)),
("12-bit per-triplet BE", unpack_12bit_per_triplet_be(blk.data)),
]
for name, pred_deltas in schemes:
n_match = sum(1 for a, b in zip(pred_deltas, truth_deltas) if a == b)
tag = "✓" if pred_deltas == truth_deltas else " "
print(f" {tag}{n_match}/{nn} {name}: {pred_deltas[:nn]}")
if __name__ == "__main__":
main()
-86
View File
@@ -1,86 +0,0 @@
"""Test: 00 NN markers might be RLE for zero-deltas in current channel."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import _parse_txt
from minimateplus.waveform_codec import walk_body, find_data_start
def s4(n):
return n if n < 8 else n - 16
def i8(b):
return b if b < 128 else b - 256
def decode_with_rle(body):
"""Decode Tran assuming:
- preamble[3:5], [5:7] = T[0], T[1]
- All 10 NN / 20 NN blocks until segment_header (40 02) are Tran deltas
- 00 NN markers are RLE: NN/4 zero T deltas (or NN, or NN/2 — try them)
"""
if len(body) < 9 or body[0:3] != b"\x00\x02\x00":
return None, None, None
T0 = int.from_bytes(body[3:5], "big", signed=True)
T1 = int.from_bytes(body[5:7], "big", signed=True)
# Find first tag (might be 00 NN, 10 NN, or 20 NN)
i = 7
while i + 1 < len(body):
if body[i] in (0x00, 0x10, 0x20):
break
i += 1
start = i
blocks = walk_body(body, start)
results = {}
for rle_div in (4, 2, 1): # try different RLE interpretations
T = [T0, T1]
cur = T1
for blk in blocks:
if blk.tag_hi == 0x40:
break
if blk.tag_hi == 0x10:
for byte in blk.data:
for nib in ((byte >> 4) & 0xF, byte & 0xF):
cur += s4(nib)
T.append(cur)
elif blk.tag_hi == 0x20:
for byte in blk.data:
cur += i8(byte)
T.append(cur)
elif blk.tag_hi == 0x00:
# RLE of zero deltas
n_zeros = blk.tag_lo // rle_div
for _ in range(n_zeros):
T.append(cur)
# 30 NN: skip for now
results[rle_div] = T
return results, T0, T1
def main():
for stem in ("M529LL1L.V70", "M529LL1L.JQ0", "M529LL1A.SP0", "M529LL1A.SS0", "M529LL1A.SV0"):
path = f"tests/fixtures/5-11-26/{stem}"
with open(path, "rb") as f:
body = f.read()[43:-26]
_, samples = _parse_txt(path + ".TXT")
truth_T = [round(v*200) for v in samples["Tran"]]
results, T0, T1 = decode_with_rle(body)
print(f"\n=== {stem} (T[0]={T0}, T[1]={T1}) ===")
for rle_div, T in results.items():
n = min(len(T), len(truth_T))
matches = sum(1 for i in range(n) if T[i] == truth_T[i])
# Find first divergence
div_at = -1
for i in range(n):
if T[i] != truth_T[i]:
div_at = i
break
print(f" rle_div={rle_div}: decoded {len(T)}, matches {matches}/{n}, first div at sample {div_at}")
if __name__ == "__main__":
main()
-71
View File
@@ -1,71 +0,0 @@
"""Test: does the second '20 NN' block in SS0 continue Tran samples?"""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import _parse_txt
from minimateplus.waveform_codec import walk_body, find_data_start
def s4(n):
return n if n < 8 else n - 16
def i8(b):
return b if b < 128 else b - 256
def main():
stem = "M529LL1A.SS0"
path = f"tests/fixtures/5-11-26/{stem}"
with open(path, "rb") as f:
body = f.read()[43:-26]
_, samples = _parse_txt(path + ".TXT")
truth_T_16 = [round(v * 200) for v in samples["Tran"]]
# Preamble
T0 = int.from_bytes(body[3:5], "big", signed=True)
T1 = int.from_bytes(body[5:7], "big", signed=True)
# Walk blocks
start = find_data_start(body)
blocks = walk_body(body, start)
print(f"=== {stem} === T[0]={T0} T[1]={T1}")
# Hypothesis: Tran continues through ALL 10 NN and 20 NN blocks
# in order, until the next 40 02 segment header (which resets).
T = [T0, T1]
cur = T1
decoded_count = 2 # T[0], T[1] from preamble
for bi, blk in enumerate(blocks):
if blk.tag_hi == 0x10:
for byte in blk.data:
for nib in ((byte >> 4) & 0xF, byte & 0xF):
cur += s4(nib)
T.append(cur)
decoded_count += 1
elif blk.tag_hi == 0x20:
for byte in blk.data:
cur += i8(byte)
T.append(cur)
decoded_count += 1
elif blk.tag_hi == 0x40:
# Segment header — stop here for this test
break
# 00 and 30 NN don't contribute to Tran (in this hypothesis)
# Compare to truth
print(f" Decoded {len(T)} T samples up to first 40 02")
matches = sum(1 for i in range(min(len(T), len(truth_T_16))) if T[i] == truth_T_16[i])
print(f" Matches in first {min(len(T), len(truth_T_16))}: {matches}")
# Print first divergence
for i in range(min(len(T), len(truth_T_16))):
if T[i] != truth_T_16[i]:
print(f" First divergence: sample {i}: pred={T[i]}, truth={truth_T_16[i]}")
# Show context
print(f" pred [{i-3}:{i+5}]: {T[max(0,i-3):i+5]}")
print(f" truth [{i-3}:{i+5}]: {truth_T_16[max(0,i-3):i+5]}")
break
if __name__ == "__main__":
main()
-67
View File
@@ -1,67 +0,0 @@
"""Try various nibble-level channel interleavings to find which one matches truth."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def s4(n):
return n if n < 8 else n - 16
def run_decoder(body, layout, skip, n_channels=4):
"""layout: function nibble_index -> channel_index. Returns list-of-lists per channel."""
out = [[] for _ in range(n_channels)]
cur = [0] * n_channels
nibbles = []
for byte in body[skip:]:
nibbles.append((byte >> 4) & 0xF)
nibbles.append(byte & 0xF)
for i, n in enumerate(nibbles):
ch = layout(i)
cur[ch] += s4(n)
out[ch].append(cur[ch])
return out
def cmp(pred, truth, n=24):
n = min(n, len(pred), len(truth))
return [(pred[i], truth[i]) for i in range(n)]
def main():
b = load_bundle("event-c")
truth_T = [round(v * 200) for v in b.samples["Tran"]]
truth_V = [round(v * 200) for v in b.samples["Vert"]]
truth_L = [round(v * 200) for v in b.samples["Long"]]
print(f"T truth[0:10]: {truth_T[:10]}")
print(f"V truth[0:10]: {truth_V[:10]}")
print(f"L truth[0:10]: {truth_L[:10]}")
# Try several nibble->channel layouts (4 channels)
layouts = {
"interleaved TVLM (0,1,2,3,0,1,2,3,...)": lambda i: i % 4,
"interleaved VLMT": lambda i: (i + 3) % 4,
"interleaved LMTV": lambda i: (i + 2) % 4,
"interleaved MTVL": lambda i: (i + 1) % 4,
"byte-based TV LM TV LM (high T low V byte0; high L low M byte1)": lambda i: i % 4,
# "chunks of 8 nibbles per channel": each channel gets 8 nibbles in a row
"chunks-8 TVLM": lambda i: (i // 8) % 4,
"chunks-16 TVLM": lambda i: (i // 16) % 4,
# planar (full channel sequential)
"planar T(0..N) V(N..2N) L(2N..3N) M(3N..4N)": None, # special
}
for label, layout_fn in layouts.items():
if layout_fn is None:
continue
for skip in (0, 4, 7, 8, 9, 11, 14):
out = run_decoder(b.body, layout_fn, skip)
# Check first 8 cumulative on each channel
print(f" skip={skip:2} {label}")
print(f" T_cum[0:10]: {out[0][:10]}")
print(f" V_cum[0:10]: {out[1][:10]}")
print(f" L_cum[0:10]: {out[2][:10]}")
if __name__ == "__main__":
main()
-73
View File
@@ -1,73 +0,0 @@
"""Try decoding body as 4-bit signed nibble deltas, 4-channel round-robin."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
CHANNELS = ("Tran", "Vert", "Long", "MicL")
def s4(n):
"""Sign-extend a 4-bit unsigned to int (0..7 → 0..7, 8..F → -8..-1)."""
return n if n < 8 else n - 16
def decode_nibbles(body: bytes, skip_bytes: int = 7, n_channels: int = 4):
"""Read body as 2 nibbles per byte; accumulate as deltas for n_channels round-robin."""
out = [[] for _ in range(n_channels)]
cur = [0] * n_channels
ch = 0
nibbles = []
for byte in body[skip_bytes:]:
nibbles.append((byte >> 4) & 0xF)
nibbles.append(byte & 0xF)
for n in nibbles:
cur[ch] += s4(n)
out[ch].append(cur[ch])
ch = (ch + 1) % n_channels
return out
def cmp_to_truth(pred, truth, scale=16):
"""Compare predicted ints (in 16-count units) to truth (in 16-count units = txt * 200).
Return (max_abs_err, mean_abs_err, n_compared).
"""
n = min(len(pred), len(truth))
errs = []
for i in range(n):
p = pred[i]
t = truth[i]
errs.append(abs(p - t))
if not errs:
return None
return (max(errs), sum(errs) / len(errs), n)
def main():
for name in ("event-a", "event-c"):
b = load_bundle(name)
# Convert TXT samples (in/s) to 16-count units (multiply by 200, since 0.005 in/s = 1)
# WAIT: 0.005 in/s = 16 ADC counts. 1 count = 0.000305 in/s.
# So in 1-count units: count = txt * (1/0.0003052) ≈ txt * 3276.7
# But TXT only has 0.005 resolution so equivalent to 16-count units = txt * 200.
truth_in_16 = {ch: [round(v * 200) for v in b.samples[ch]] for ch in CHANNELS[:3]}
# MicL is in dB, skip for now
# Try decoder with skip_bytes = 7
decoded = decode_nibbles(b.body, skip_bytes=7, n_channels=4)
print(f"\n=== {name} ===")
print(f" body={len(b.body)}, nibbles={2*(len(b.body)-7)}, samples_per_ch={len(decoded[0])}")
print(f" truth samples per ch: {len(truth_in_16['Tran'])}")
# Print first 24 of each
for i, chan in enumerate(CHANNELS):
pred_first = decoded[i][:24]
if chan in truth_in_16:
truth_first = truth_in_16[chan][:24]
print(f" {chan} pred: {pred_first}")
print(f" {chan} truth: {truth_first}")
else:
print(f" {chan} pred: {pred_first} (truth in dB, skipped)")
if __name__ == "__main__":
main()
-32
View File
@@ -1,32 +0,0 @@
"""Verify decode_waveform_v2 against BW ASCII truth for all fixtures."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import _parse_txt
from minimateplus.waveform_codec import decode_waveform_v2
def main():
for stem in ("M529LL1A.SP0", "M529LL1A.SS0", "M529LL1A.SV0",
"M529LL1L.JQ0", "M529LL1L.V70"):
path = f"tests/fixtures/5-11-26/{stem}"
with open(path, "rb") as f:
body = f.read()[43:-26]
_, samples = _parse_txt(path + ".TXT")
decoded = decode_waveform_v2(body)
if decoded is None:
print(f"{stem}: decoder returned None")
continue
print(f"\n=== {stem} ===")
for ch in ("Tran", "Vert", "Long"):
truth = [round(v * 200) for v in samples[ch]]
pred = decoded[ch]
n = min(len(pred), len(truth))
matches = sum(1 for i in range(n) if pred[i] == truth[i])
div = next((i for i in range(n) if pred[i] != truth[i]), -1)
print(f" {ch}: decoded={len(pred):>5} truth={len(truth):>5} "
f"matches={matches:>5}/{n:<5} first div={div}")
if __name__ == "__main__":
main()
-55
View File
@@ -1,55 +0,0 @@
"""Run decode_waveform_v2 against the 5-8-26 quiet bundle to test the
'quiet events should decode fully' hypothesis."""
import os, sys
sys.path.insert(0, ".")
from minimateplus.waveform_codec import decode_waveform_v2, walk_body, find_data_start
from analysis.load_bundle import _parse_txt
def main():
base = "tests/fixtures/decode-re-5-8-26"
for evt in sorted(os.listdir(base)):
folder = os.path.join(base, evt)
if not os.path.isdir(folder):
continue
# Find the binary (not .TXT)
bin_name = next(
(f for f in os.listdir(folder) if not f.endswith(".TXT")),
None,
)
if not bin_name:
continue
bin_path = os.path.join(folder, bin_name)
txt_path = bin_path + ".TXT"
if not os.path.exists(txt_path):
# Sometimes the TXT name differs slightly
for f in os.listdir(folder):
if f.endswith(".TXT"):
txt_path = os.path.join(folder, f)
break
with open(bin_path, "rb") as f:
body = f.read()[43:-26]
decoded = decode_waveform_v2(body)
_, samples = _parse_txt(txt_path)
# Count 30 NN blocks
blocks = walk_body(body, find_data_start(body))
n_30 = sum(1 for b in blocks if b.tag_hi == 0x30)
n_40 = sum(1 for b in blocks if b.tag_hi == 0x40)
print(f"\n=== {evt} === body={len(body)} segments={n_40} '30 NN' blocks={n_30}")
if decoded is None:
print(" decoder returned None")
continue
for ch in ("Tran", "Vert", "Long"):
truth = [round(v * 200) for v in samples[ch]]
pred = decoded[ch]
n = min(len(pred), len(truth))
matches = sum(1 for i in range(n) if pred[i] == truth[i])
div = next((i for i in range(n) if pred[i] != truth[i]), -1)
print(f" {ch}: decoded={len(pred):>5} truth={len(truth):>5} "
f"matches={matches:>5}/{n:<5} first div={div}")
if __name__ == "__main__":
main()
-71
View File
@@ -1,71 +0,0 @@
"""Verify: preamble[3:7] = Tran[0], Tran[1] as int16 BE in 16-count units.
And first 20/10 NN block = Tran deltas starting at sample 2.
"""
import os, sys
sys.path.insert(0, ".")
from analysis.load_bundle import _parse_txt
from minimateplus.waveform_codec import walk_body, find_data_start
def s4(n):
return n if n < 8 else n - 16
def i8(b):
return b if b < 128 else b - 256
def main():
for stem in ("M529LL1A.SP0", "M529LL1A.SS0", "M529LL1A.SV0"):
path = f"tests/fixtures/5-11-26/{stem}"
with open(path, "rb") as f:
raw = f.read()
body = raw[43:-26]
_, samples = _parse_txt(path + ".TXT")
truth_T_16 = [round(v * 200) for v in samples["Tran"]]
# Preamble parse
T0_pre = int.from_bytes(body[3:5], "big", signed=True)
T1_pre = int.from_bytes(body[5:7], "big", signed=True)
print(f"\n=== {stem} ===")
print(f" Preamble T[0]={T0_pre} (truth {truth_T_16[0]}) T[1]={T1_pre} (truth {truth_T_16[1]}) match={T0_pre==truth_T_16[0] and T1_pre==truth_T_16[1]}")
# First block
start = find_data_start(body)
blocks = walk_body(body, start)
if not blocks:
print(f" no blocks found")
continue
# Assume first block = Tran deltas from sample 2
first = blocks[0]
T = [T0_pre, T1_pre]
cur_T = T1_pre
if first.tag_hi == 0x10:
# Nibble pairs
for byte in first.data:
for nib in ((byte >> 4) & 0xF, byte & 0xF):
cur_T += s4(nib)
T.append(cur_T)
elif first.tag_hi == 0x20:
# int8 per byte
for byte in first.data:
cur_T += i8(byte)
T.append(cur_T)
# Compare against truth
n_check = min(len(T), len(truth_T_16))
match_count = sum(1 for i in range(n_check) if T[i] == truth_T_16[i])
print(f" First block type=0x{first.tag_hi:02x} NN=0x{first.tag_lo:02x} len={len(first.data)} → {len(T)} T samples decoded")
print(f" Tran predicted[0:10]: {T[:10]}")
print(f" Tran truth [0:10]: {truth_T_16[:10]}")
print(f" Matches in first {n_check}: {match_count} / {n_check}")
# Show where it diverges
for i in range(n_check):
if T[i] != truth_T_16[i]:
print(f" First divergence: sample {i}: pred={T[i]}, truth={truth_T_16[i]}")
break
if __name__ == "__main__":
main()
-20
View File
@@ -1,20 +0,0 @@
"""Walk blocks of the new 5-11-26 events and look at what comes after Tran block."""
import sys
sys.path.insert(0, ".")
from minimateplus.waveform_codec import walk_body, find_data_start
def main():
for stem in ("M529LL1A.SP0", "M529LL1A.SS0", "M529LL1A.SV0"):
with open(f"tests/fixtures/5-11-26/{stem}", "rb") as f:
raw = f.read()
body = raw[43:-26]
start = find_data_start(body)
blocks = walk_body(body, start)
print(f"\n=== {stem} === body={len(body)} start={start} blocks walked={len(blocks)}")
for i, b in enumerate(blocks[:20]):
print(f" block[{i:>2}] @ {b.offset:>5} tag={b.tag_hi:02x} NN=0x{b.tag_lo:02x}({b.tag_lo}) len={b.length} data[:24]={b.data[:24].hex(' ')}")
if __name__ == "__main__":
main()
-44
View File
@@ -1,44 +0,0 @@
"""Walk the body assuming chunks delimited by 0x10 NN tags. Print each chunk's structure."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def walk(body: bytes, start_offset: int = 7, max_chunks: int = 30):
"""Find all positions where byte = 0x10 followed by a multiple-of-4 byte. Print chunks."""
chunks = []
i = start_offset
while i < len(body) - 1:
# Find next `10 NN` where NN is multiple of 4 (and not preceded by another 0x10 immediately, which would be data).
if body[i] == 0x10 and (body[i+1] % 4 == 0):
chunks.append(i)
i += 1
return chunks
def main():
for name in ("event-c", "event-d"):
b = load_bundle(name)
body = b.body
positions = []
i = 7 # skip 7-byte preamble
while i < len(body) - 1:
if body[i] == 0x10 and body[i+1] % 4 == 0 and body[i+1] > 0:
positions.append(i)
i += 2 # skip past tag
else:
i += 1
print(f"\n=== {name} === body={len(body)}, total `10 NN` (NN%4==0, NN>0) tags: {len(positions)}")
# Print first 20 chunks: show position, NN, gap to next tag
for k in range(min(30, len(positions))):
pos = positions[k]
NN = body[pos + 1]
next_pos = positions[k+1] if k+1 < len(positions) else len(body)
gap = next_pos - pos
data_bytes = body[pos+2 : next_pos]
print(f" chunk[{k:>3}] @ {pos:>5} NN=0x{NN:02x} ({NN:>3}, NN/2={NN//2}) gap={gap:>3} "
f"data={data_bytes[:24].hex(' ')}{'...' if len(data_bytes) > 24 else ''}")
if __name__ == "__main__":
main()
-50
View File
@@ -1,50 +0,0 @@
"""Deterministic chunk walker: each chunk = [10 NN][NN/2 bytes data][2 bytes trailer]."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def walk_chunks(body: bytes, start: int = 7):
"""Yield (offset, NN, data_bytes, trailer_bytes) tuples."""
i = start
while i + 1 < len(body):
if body[i] != 0x10:
break
NN = body[i + 1]
if NN == 0 or NN > 0x80 or NN % 4 != 0:
break
chunk_len = NN // 2 + 4
if i + chunk_len > len(body):
break
data = bytes(body[i + 2 : i + 2 + NN // 2])
trailer = bytes(body[i + 2 + NN // 2 : i + chunk_len])
yield (i, NN, data, trailer)
i += chunk_len
def main():
for name in ("event-c", "event-d", "event-a", "event-b"):
b = load_bundle(name)
body = b.body
chunks = list(walk_chunks(body))
print(f"\n=== {name} === body={len(body)} N_samples={len(b.samples['Tran'])}")
print(f" chunks parsed: {len(chunks)}")
if chunks:
last = chunks[-1]
end_of_walk = last[0] + last[1] // 2 + 4
print(f" walk ended at offset {end_of_walk} (= {len(body) - end_of_walk} bytes from end)")
# Stats
total_data_bytes = sum(len(c[2]) for c in chunks)
print(f" total data bytes: {total_data_bytes}, total nibbles: {2*total_data_bytes}")
if name in ("event-c", "event-d"):
ratio = (2 * total_data_bytes) / (len(b.samples['Tran']) * 4)
print(f" nibbles per (sample × channel): {ratio:.3f}")
# Sum of trailer second-byte
trailer_sums = [c[3][-1] if c[3] else None for c in chunks]
print(f" first 10 chunks: {[(c[0], c[1], c[3].hex()) for c in chunks[:10]]}")
# Print last 10 chunks (likely transition to trailer)
print(f" last 10 chunks: {[(c[0], c[1], c[3].hex()) for c in chunks[-10:]]}")
if __name__ == "__main__":
main()
-51
View File
@@ -1,51 +0,0 @@
"""Walk chunks; auto-detect preamble length by finding first 10 NN."""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def walk_chunks(body, start, max_NN=0x80):
chunks = []
i = start
while i + 1 < len(body):
if body[i] != 0x10:
break
NN = body[i + 1]
if NN == 0 or NN > max_NN or NN % 4 != 0:
break
chunk_len = NN // 2 + 4
if i + chunk_len > len(body):
break
data = bytes(body[i + 2 : i + 2 + NN // 2])
trailer = bytes(body[i + 2 + NN // 2 : i + chunk_len])
chunks.append((i, NN, data, trailer))
i += chunk_len
return chunks, i
def find_first_chunk_start(body):
"""Locate first byte that begins a `10 NN` chunk (NN ∈ multiples of 4, 4..0x7C)."""
for i in range(20):
if body[i] == 0x10 and body[i + 1] % 4 == 0 and 0 < body[i + 1] <= 0x7C:
return i
return -1
def main():
for name in ("event-c", "event-d", "event-a", "event-b"):
b = load_bundle(name)
body = b.body
start = find_first_chunk_start(body)
chunks, end = walk_chunks(body, start)
print(f"\n=== {name} === body={len(body)} N_samples={len(b.samples['Tran'])} start={start}")
print(f" chunks parsed: {len(chunks)}, walk ended at {end}")
if chunks:
print(f" first 5 chunks: {[(c[0], c[1], c[3].hex()) for c in chunks[:5]]}")
print(f" last 5 chunks: {[(c[0], c[1], c[3].hex()) for c in chunks[-5:]]}")
print(f" bytes around end of walk: {body[end-4:end+12].hex(' ')}")
else:
print(f" bytes at start: {body[start:start+16].hex(' ')}")
if __name__ == "__main__":
main()
-75
View File
@@ -1,75 +0,0 @@
"""
Walker v4: alternate [10 NN] data chunks and [00 NN] (or other) marker tags.
Hypothesis:
- [10 NN]: data block, length NN/2 + 2 bytes (2-byte tag + NN/2 bytes data)
- [00 NN]: 2-byte marker block (no data)
- [20/30/40 NN]: special blocks with type-dependent length
"""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
def walk(body, start):
i = start
blocks = []
while i + 1 < len(body):
t0 = body[i]
t1 = body[i + 1]
if t0 == 0x10 and t1 % 4 == 0 and 0 < t1 <= 0x80:
# data chunk: length NN/2 + 2
length = t1 // 2 + 2
blocks.append((i, "10", t1, bytes(body[i + 2 : i + length]), length))
i += length
elif t0 == 0x00 and t1 % 4 == 0:
# 2-byte marker
blocks.append((i, "00", t1, b"", 2))
i += 2
elif t0 == 0x20 and t1 % 4 == 0:
# type 2 — try length 2+t1/2 (similar to 10) OR fixed
length = t1 // 2 + 2
blocks.append((i, "20", t1, bytes(body[i + 2 : i + length]), length))
i += length
elif t0 == 0x30 and t1 % 4 == 0:
length = t1 // 2 + 2
blocks.append((i, "30", t1, bytes(body[i + 2 : i + length]), length))
i += length
elif t0 == 0x40 and t1 == 0x02:
# Special "footer transition" block — try fixed 22 bytes
length = 22
blocks.append((i, "40", t1, bytes(body[i + 2 : i + length]), length))
i += length
else:
# Unknown tag — stop
blocks.append((i, "??", t0, bytes(body[i:i+8]), 0))
break
return blocks, i
def main():
for name in ("event-c", "event-d", "event-a", "event-b"):
b = load_bundle(name)
body = b.body
# Auto-detect start
for s in range(15):
if body[s] == 0x10 and body[s+1] % 4 == 0 and 0 < body[s+1] <= 0x80:
start = s
break
else:
start = 7
blocks, end = walk(body, start)
# Categorize
from collections import Counter
types = Counter(b[1] for b in blocks)
print(f"\n=== {name} === body={len(body)} N={len(b.samples['Tran'])} start={start}")
print(f" total blocks: {len(blocks)}, walk ended at {end}/{len(body)}")
print(f" type counts: {dict(types)}")
# Print last 5 blocks
print(f" last 5 blocks: {[(bb[0], bb[1], bb[2]) for bb in blocks[-5:]]}")
if end < len(body):
print(f" bytes at end: {body[end:end+24].hex(' ')}")
if __name__ == "__main__":
main()
-83
View File
@@ -1,83 +0,0 @@
"""
Walker v5: flexible NN range and multiple block-type lengths.
Hypothesis:
- [10 NN]: 4-bit-delta data block, length = NN/2 + 2
- [20 NN]: 8-bit-literal data block, length = NN + 2
- [00 NN]: 2-byte marker (no payload)
- [30 NN]: trailer/summary block, length = NN*4
- [40 NN]: footer-marker block, fixed 22 bytes
"""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
from collections import Counter
def walk(body, start, max_blocks=10000):
i = start
blocks = []
while i + 1 < len(body) and len(blocks) < max_blocks:
t0 = body[i]
t1 = body[i + 1]
if t0 == 0x10 and t1 % 4 == 0 and 0 < t1 <= 0xFC:
length = t1 // 2 + 2
if i + length > len(body):
break
data = bytes(body[i + 2 : i + length])
blocks.append((i, "10", t1, data, length))
i += length
elif t0 == 0x20 and t1 % 4 == 0 and 0 < t1 <= 0xFC:
length = t1 + 2
if i + length > len(body):
break
data = bytes(body[i + 2 : i + length])
blocks.append((i, "20", t1, data, length))
i += length
elif t0 == 0x00 and t1 % 4 == 0:
# 2-byte marker
blocks.append((i, "00", t1, b"", 2))
i += 2
elif t0 == 0x30 and t1 % 4 == 0:
length = t1 * 4
if i + length > len(body):
break
data = bytes(body[i + 2 : i + length])
blocks.append((i, "30", t1, data, length))
i += length
elif t0 == 0x40 and t1 == 0x02:
length = 22
if i + length > len(body):
break
data = bytes(body[i + 2 : i + length])
blocks.append((i, "40", t1, data, length))
i += length
else:
blocks.append((i, "??", t0, bytes(body[i:i+8]), 0))
break
return blocks, i
def main():
for name in ("event-c", "event-d", "event-a", "event-b"):
b = load_bundle(name)
body = b.body
for s in range(15):
if body[s] == 0x10 and body[s+1] % 4 == 0 and 0 < body[s+1] <= 0xFC:
start = s; break
else:
start = 7
blocks, end = walk(body, start)
types = Counter(bb[1] for bb in blocks)
print(f"\n=== {name} === body={len(body)} N={len(b.samples['Tran'])} start={start}")
print(f" total blocks: {len(blocks)}, walk ended at {end}/{len(body)}")
print(f" type counts: {dict(types)}")
if blocks and blocks[-1][1] == "??":
print(f" stopped at byte: 0x{blocks[-1][2]:02x}, prev 5 blocks: {[(bb[0], bb[1], bb[2]) for bb in blocks[-6:-1]]}")
# Sum payload sizes by type
payload_sizes = {t: sum(len(bb[3]) for bb in blocks if bb[1] == t) for t in types}
print(f" payload bytes by type: {payload_sizes}")
if __name__ == "__main__":
main()
-68
View File
@@ -1,68 +0,0 @@
"""
Walker v6: handle 40 02 blocks correctly (length 20).
Block formats:
- [10 NN]: 4-bit nibble delta data, length = NN/2 + 2
- [20 NN]: int8 literal data, length = NN + 2
- [00 NN]: 2-byte marker
- [30 NN]: trailer/summary block, length = NN*4
- [40 02]: segment header, fixed length 20
"""
import sys
sys.path.insert(0, ".")
from analysis.load_bundle import load_bundle
from collections import Counter
def walk(body, start, max_blocks=10000):
i = start
blocks = []
while i + 1 < len(body) and len(blocks) < max_blocks:
t0 = body[i]
t1 = body[i + 1]
if t0 == 0x10 and t1 % 4 == 0 and 0 < t1 <= 0xFC:
length = t1 // 2 + 2
elif t0 == 0x20 and t1 % 4 == 0 and 0 < t1 <= 0xFC:
length = t1 + 2
elif t0 == 0x00 and t1 % 4 == 0:
length = 2
elif t0 == 0x30 and t1 % 4 == 0 and 0 < t1 <= 0x10:
length = t1 * 4
elif t0 == 0x40 and t1 == 0x02:
length = 20
else:
blocks.append((i, "??", t0, bytes(body[i:i+8]), 0))
break
if i + length > len(body):
break
data = bytes(body[i + 2 : i + length])
blocks.append((i, f"{t0:02x}", t1, data, length))
i += length
return blocks, i
def main():
for name in ("event-c", "event-d", "event-a", "event-b"):
b = load_bundle(name)
body = b.body
for s in range(15):
if body[s] == 0x10 and body[s+1] % 4 == 0 and 0 < body[s+1] <= 0xFC:
start = s; break
else:
start = 7
blocks, end = walk(body, start)
types = Counter(bb[1] for bb in blocks)
print(f"\n=== {name} === body={len(body)} N={len(b.samples['Tran'])} start={start}")
print(f" total blocks: {len(blocks)}, walk ended at {end}/{len(body)}")
print(f" type counts: {dict(types)}")
if blocks and blocks[-1][1] == "??":
print(f" stopped at byte: 0x{blocks[-1][2]:02x} at offset {blocks[-1][0]}")
print(f" prev 5 blocks: {[(bb[0], bb[1], bb[2]) for bb in blocks[-6:-1]]}")
print(f" bytes around stop: {body[end-4:end+24].hex(' ')}")
# Sum
payload_sizes = {t: sum(len(bb[3]) for bb in blocks if bb[1] == t) for t in types}
print(f" payload bytes by type: {payload_sizes}")
if __name__ == "__main__":
main()
-65
View File
@@ -1,65 +0,0 @@
"""Run read_idf_file across the corpus and report per-channel accuracy vs sidecars."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from micromate.idf_file import read_idf_file
from analysis_idf.recon import load_sidecar_samples
def sidecar_path(idfw: Path) -> Path:
return idfw.parent / "TXT" / f"{idfw.name}.txt"
def main():
root = REPO / "tests/fixtures/THORDATA_example"
files = [f for f in root.rglob("*.IDFW") if not str(f).endswith(".CDB")]
files.sort()
GEO_LSB = 0.0003
n_ok = n_skip = 0
overall = {"Tran": [], "Vert": [], "Long": []}
for f in files:
try:
res = read_idf_file(f)
except Exception:
n_skip += 1
continue
sc_path = sidecar_path(f)
if not sc_path.exists():
n_skip += 1
continue
try:
sc = load_sidecar_samples(sc_path)
except Exception:
n_skip += 1
continue
per_file = {}
for ch in ("Tran", "Vert", "Long"):
sc_counts = [int(round(v / GEO_LSB)) for v in sc[ch]]
dec = res.samples.get(ch, [])
n = min(len(sc_counts), len(dec))
if n == 0:
per_file[ch] = 0.0
continue
exact = sum(1 for i in range(n) if sc_counts[i] == dec[i])
pct = 100.0 * exact / n
per_file[ch] = pct
overall[ch].append(pct)
n_ok += 1
print(f"Processed {n_ok} files (skipped {n_skip})")
print("Per-channel exact-match % (mean / min / max):")
for ch, vals in overall.items():
if vals:
avg = sum(vals) / len(vals)
print(f" {ch}: mean={avg:.2f}% min={min(vals):.2f}% max={max(vals):.2f}% n={len(vals)}")
if __name__ == "__main__":
main()
-49
View File
@@ -1,49 +0,0 @@
"""Find where decoded-vs-sidecar diverges for each channel."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from minimateplus.waveform_codec import decode_waveform_v2
from analysis_idf.recon import TARGET, TXT, load_sidecar_samples
def main():
buf = TARGET.read_bytes()
sc = load_sidecar_samples(TXT)
decoded = decode_waveform_v2(buf[0x0f1f:])
GEO_LSB = 0.0003
for ch in ("Tran", "Vert", "Long"):
sc_counts = [int(round(v / GEO_LSB)) for v in sc[ch]]
dec = decoded[ch]
# Find ALL transitions where mismatches start/stop
first_diff = next((i for i in range(len(dec)) if dec[i] != sc_counts[i]), None)
if first_diff is None:
print(f"{ch}: NO MISMATCHES")
continue
print(f"{ch}: first diff at idx {first_diff}")
# Show 5 before, 5 after
for i in range(max(0, first_diff - 3), min(len(dec), first_diff + 8)):
mark = " " if dec[i] == sc_counts[i] else "**"
print(f" {mark} idx {i:4d}: sc={sc_counts[i]:6d} dec={dec[i]:6d} diff={dec[i]-sc_counts[i]:+d}")
# Where does cumulative diff exceed 100?
cum_match_run = 0
max_match_run = 0
match_run_start = 0
diff_count = 0
for i in range(len(dec)):
if dec[i] == sc_counts[i]:
cum_match_run += 1
max_match_run = max(max_match_run, cum_match_run)
else:
cum_match_run = 0
diff_count += 1
print(f" total mismatches: {diff_count}/{len(dec)}, longest run of matches: {max_match_run}")
print()
if __name__ == "__main__":
main()
-48
View File
@@ -1,48 +0,0 @@
"""End-to-end IDFH ingest verification."""
from __future__ import annotations
import sys
import tempfile
import json
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from sfm.waveform_store import WaveformStore
def main():
idfh = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM13981/UM13981_20220805075441.IDFH"
txt = idfh.parent / "TXT" / f"{idfh.name}.txt"
with tempfile.TemporaryDirectory() as td:
store = WaveformStore(Path(td))
ev, rec = store.save_imported_idf(
idfh.read_bytes(),
idfh,
idf_report_text=txt.read_text(errors="replace"),
)
print("=== save_imported_idf (IDFH) ===")
print(f" serial: {rec['serial']}")
print(f" filename: {rec['filename']}")
print(f" filesize: {rec['filesize']}")
print(f" h5: {rec['hdf5_filename']}") # expect None for histogram
print(f" sidecar: {rec['sidecar_filename']}")
print()
print("=== Event ===")
print(f" timestamp: {ev.timestamp}")
print(f" record_type: {ev.record_type}")
print(f" sample_rate: {ev.sample_rate}")
print()
# Inspect sidecar to confirm intervals were stashed
sc_path = Path(td) / "UM13981" / f"{idfh.name}.sfm.json"
sc = json.loads(sc_path.read_text())
intervals = sc.get("extensions", {}).get("idf_intervals", [])
print(f" sidecar intervals: {len(intervals)}")
if intervals:
print(f" first interval: {intervals[0]}")
print(f" last interval: {intervals[-1]}")
if __name__ == "__main__":
main()
-40
View File
@@ -1,40 +0,0 @@
"""Verify the had_report=False path: ingest IDFW with no .txt."""
from __future__ import annotations
import sys
from pathlib import Path
import tempfile
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from sfm.waveform_store import WaveformStore
def main():
idfw = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM11719/UM11719_20231219162723.IDFW"
with tempfile.TemporaryDirectory() as td:
store = WaveformStore(Path(td))
ev, rec = store.save_imported_idf(
idfw.read_bytes(),
idfw,
serial_hint=None,
idf_report_text=None, # ← no .txt!
)
print("=== IDFW without .txt ingest ===")
print(f" serial: {rec['serial']}")
print(f" timestamp: {ev.timestamp}")
print(f" sample_rate: {ev.sample_rate}")
print(f" record_type: {ev.record_type}")
print(f" rectime_sec: {ev.rectime_seconds}")
nT = len(ev.raw_samples.get('Tran', [])) if ev.raw_samples else 0
nV = len(ev.raw_samples.get('Vert', [])) if ev.raw_samples else 0
nL = len(ev.raw_samples.get('Long', [])) if ev.raw_samples else 0
nM = len(ev.raw_samples.get('MicL', [])) if ev.raw_samples else 0
print(f" raw_samples: Tran={nT} Vert={nV} Long={nL} MicL={nM}")
if ev.peak_values:
print(f" peak_values: tran={ev.peak_values.tran} vert={ev.peak_values.vert} long={ev.peak_values.long}")
print(f" h5 written: {rec['hdf5_filename']}")
if __name__ == "__main__":
main()
-102
View File
@@ -1,102 +0,0 @@
"""End-to-end Thor report PDF rendering.
Ingests an IDFW + .txt via save_imported_idf, runs gather_report_data
(faking a minimal DB row), and renders the PDF to disk.
"""
from __future__ import annotations
import sys
import tempfile
import json
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from sfm.waveform_store import WaveformStore
from sfm import report_pdf
class FakeDb:
"""Stand-in for SeismoDb.get_event(); the renderer only needs a few cols."""
def __init__(self, event):
self.event = event
def get_event(self, _id):
return self.event
def main():
base = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM11719"
idfw = base / "UM11719_20231219162723.IDFW"
txt = base / "TXT" / f"{idfw.name}.txt"
with tempfile.TemporaryDirectory() as td:
store = WaveformStore(Path(td))
ev, rec = store.save_imported_idf(
idfw.read_bytes(),
idfw,
idf_report_text=txt.read_text(errors="replace"),
)
print(f"save_imported_idf: h5={rec['hdf5_filename']}, sidecar={rec['sidecar_filename']}")
# Verify sidecar has bw_report block
sc_path = Path(td) / "UM11719" / f"{idfw.name}.sfm.json"
sc = json.loads(sc_path.read_text())
bw = sc.get("bw_report", {})
print(f" bw_report.available: {bw.get('available')}")
print(f" bw_report.peaks.tran.ppv_ips: {bw.get('peaks', {}).get('tran', {}).get('ppv_ips')}")
print(f" bw_report.mic.pspl_dbl: {bw.get('mic', {}).get('pspl_dbl')}")
print(f" bw_report.histogram.n_intervals: {bw.get('histogram', {}).get('n_intervals')}")
# Build a DB-row-shaped dict from the Event for gather_report_data
import datetime
ts = ev.timestamp
ts_iso = None
if ts is not None:
try:
ts_iso = datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second).isoformat()
except Exception:
pass
fake_row = {
"serial": "UM11719",
"blastware_filename": rec["filename"],
"record_type": "Waveform",
"timestamp": ts_iso,
"sample_rate": ev.sample_rate,
"project": ev.project_info.project if ev.project_info else None,
"client": ev.project_info.client if ev.project_info else None,
"operator": ev.project_info.operator if ev.project_info else None,
"sensor_location": ev.project_info.sensor_location if ev.project_info else None,
"created_at": None,
}
rd = report_pdf.gather_report_data(FakeDb(fake_row), store, event_id="test-1")
print()
print(f"=== ReportData ===")
print(f" event_id: {rd.event_id}")
print(f" serial: {rd.serial}")
print(f" record_type: {rd.record_type}")
print(f" event_datetime: {rd.event_datetime_str}")
print(f" trigger: {rd.trigger_source}")
print(f" geo_range: {rd.geo_range_str}")
print(f" sample_rate: {rd.sample_rate_str}")
print(f" firmware: {rd.firmware}")
print(f" calibration: {rd.calibration_date} by {rd.calibration_by}")
print(f" battery: {rd.battery_volts}")
print(f" PVS: {rd.peak_vector_sum_ips} in/s at {rd.peak_vector_sum_time_s} sec")
print(f" mic_pspl_dbl: {rd.mic_pspl_dbl}")
print(f" mic_zc_freq_hz: {rd.mic_zc_freq_hz}")
print(f" channel_stats: {len(rd.channel_stats)} rows")
for cs in rd.channel_stats:
print(f" {cs['name']}: PPV={cs['ppv_ips']} ZC={cs['zc_freq_hz']} ToP={cs['time_of_peak_s']} Acc={cs['peak_accel_g']} Disp={cs['peak_disp_in']} Test={cs['sensor_check']}")
# Render the PDF
out_path = REPO / "analysis_idf" / "thor_report.pdf"
pdf_bytes = report_pdf.render_event_report_pdf(rd)
out_path.write_bytes(pdf_bytes)
print()
print(f" PDF written: {out_path} ({len(pdf_bytes)} bytes)")
if __name__ == "__main__":
main()
-91
View File
@@ -1,91 +0,0 @@
"""End-to-end Thor IDFH histogram report PDF rendering."""
from __future__ import annotations
import sys
import tempfile
import json
import datetime
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from sfm.waveform_store import WaveformStore
from sfm import report_pdf
class FakeDb:
def __init__(self, event):
self.event = event
def get_event(self, _id):
return self.event
def main():
# Use the multi-interval IDFH (81 + trigger row)
idfh = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM13981/UM13981_20220805075441.IDFH"
txt = idfh.parent / "TXT" / f"{idfh.name}.txt"
with tempfile.TemporaryDirectory() as td:
store = WaveformStore(Path(td))
ev, rec = store.save_imported_idf(
idfh.read_bytes(),
idfh,
idf_report_text=txt.read_text(errors="replace"),
)
print(f"save_imported_idf: h5={rec['hdf5_filename']}, sidecar={rec['sidecar_filename']}")
sc_path = Path(td) / "UM13981" / f"{idfh.name}.sfm.json"
sc = json.loads(sc_path.read_text())
bw = sc.get("bw_report", {})
hist = bw.get("histogram", {})
print(f" bw_report.histogram.start: {hist.get('start')}")
print(f" bw_report.histogram.stop: {hist.get('stop')}")
print(f" bw_report.histogram.n_intervals: {hist.get('n_intervals')}")
print(f" bw_report.histogram.interval_size: {hist.get('interval_size')}")
print(f" bw_report.histogram.interval_size_s: {hist.get('interval_size_s')}")
print(f" bw_report.peaks.tran.ppv_ips: {bw.get('peaks', {}).get('tran', {}).get('ppv_ips')}")
ts = ev.timestamp
ts_iso = None
if ts is not None:
try:
ts_iso = datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second).isoformat()
except Exception:
pass
fake_row = {
"serial": "UM13981",
"blastware_filename": rec["filename"],
"record_type": "Histogram",
"timestamp": ts_iso,
"sample_rate": ev.sample_rate,
"project": ev.project_info.project if ev.project_info else None,
"client": ev.project_info.client if ev.project_info else None,
"operator": ev.project_info.operator if ev.project_info else None,
"sensor_location": ev.project_info.sensor_location if ev.project_info else None,
"created_at": None,
}
rd = report_pdf.gather_report_data(FakeDb(fake_row), store, event_id="hist-1")
print()
print("=== ReportData (histogram) ===")
print(f" is_histogram: {rd.is_histogram}")
print(f" histogram_start: {rd.histogram_start_str}")
print(f" histogram_stop: {rd.histogram_stop_str}")
print(f" histogram_n_intervals: {rd.histogram_n_intervals}")
print(f" histogram_interval_size:{rd.histogram_interval_size}")
print(f" histogram_interval_times[:3]: {rd.histogram_interval_times[:3]}")
print(f" histogram_interval_times[-2:]: {rd.histogram_interval_times[-2:]}")
print(f" channel_stats: {len(rd.channel_stats)} rows")
for cs in rd.channel_stats:
print(f" {cs['name']}: PPV={cs['ppv_ips']} ZC={cs['zc_freq_hz']} peak_date={cs['peak_date']} peak_time={cs['peak_time']}")
pdf_bytes = report_pdf.render_event_report_pdf(rd)
out_path = REPO / "analysis_idf" / "thor_report_idfh.pdf"
out_path.write_bytes(pdf_bytes)
print()
print(f" PDF written: {out_path} ({len(pdf_bytes)} bytes)")
if __name__ == "__main__":
main()
-52
View File
@@ -1,52 +0,0 @@
"""End-to-end ingest test: feed an IDFW + .txt to save_imported_idf in a tmp store."""
from __future__ import annotations
import sys
from pathlib import Path
import tempfile
import shutil
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from sfm.waveform_store import WaveformStore
def main():
idfw = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM11719/UM11719_20231219162723.IDFW"
txt = idfw.parent / "TXT" / f"{idfw.name}.txt"
with tempfile.TemporaryDirectory() as td:
store = WaveformStore(Path(td))
ev, rec = store.save_imported_idf(
idfw.read_bytes(),
idfw,
serial_hint=None,
idf_report_text=txt.read_text(errors="replace"),
)
print("=== Save result ===")
print(f" serial: {rec['serial']}")
print(f" filename: {rec['filename']}")
print(f" filesize: {rec['filesize']}")
print(f" h5: {rec['hdf5_filename']}")
print(f" sidecar: {rec['sidecar_filename']}")
print()
print("=== Event ===")
print(f" serial: {ev.serial if hasattr(ev,'serial') else '(n/a)'}")
print(f" timestamp: {ev.timestamp}")
print(f" sample_rate: {ev.sample_rate}")
print(f" record_type: {ev.record_type}")
print(f" rectime_sec: {ev.rectime_seconds}")
print(f" raw_samples: Tran={len(ev.raw_samples.get('Tran', [])) if ev.raw_samples else 0}, Vert={len(ev.raw_samples.get('Vert', [])) if ev.raw_samples else 0}, Long={len(ev.raw_samples.get('Long', [])) if ev.raw_samples else 0}, MicL={len(ev.raw_samples.get('MicL', [])) if ev.raw_samples else 0}")
if ev.peak_values:
print(f" peaks (txt): Tran={ev.peak_values.tran} Vert={ev.peak_values.vert} Long={ev.peak_values.long}")
print()
# Verify the h5 file actually got written
h5path = Path(td) / "UM11719" / f"{idfw.name}.h5"
print(f" h5 exists: {h5path.exists()} size={h5path.stat().st_size if h5path.exists() else 0}")
sidecar = Path(td) / "UM11719" / f"{idfw.name}.sfm.json"
print(f" sidecar exists:{sidecar.exists()} size={sidecar.stat().st_size if sidecar.exists() else 0}")
if __name__ == "__main__":
main()
-137
View File
@@ -1,137 +0,0 @@
"""Decode IDFH histogram intervals + verify against sidecar."""
from __future__ import annotations
import sys
import struct
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
SEGMENT_MAGIC = b"\x02\xda\x0a\x00\x00\x00"
SEGMENT_SIZE = 732 # = 10-byte header + 10 × 72-byte intervals + 2-byte tail
INTERVAL_SIZE = 72
CHANNELS = ("Tran", "Vert", "Long", "MicL")
def decode_interval(buf72: bytes) -> dict:
"""Decode one 72-byte interval into per-channel min/max/halfp."""
out = {}
for i, ch in enumerate(CHANNELS):
block = buf72[i*16 : (i+1)*16]
mn = struct.unpack_from(">h", block, 0)[0]
mx = struct.unpack_from(">h", block, 2)[0]
sb = struct.unpack_from(">h", block, 4)[0]
halfp = struct.unpack_from(">H", block, 6)[0]
f10 = struct.unpack_from(">H", block, 10)[0]
f14 = struct.unpack_from(">H", block, 14)[0]
peak_count = max(abs(mn), abs(mx))
out[ch] = {
"min": mn,
"max": mx,
"field4": sb,
"halfp": halfp,
"field10": f10,
"field14": f14,
"peak": peak_count,
"freq_hz": (512.0 / halfp) if halfp > 5 else None,
}
out["_tail"] = buf72[64:].hex(" ")
return out
def walk_idfh(buf: bytes) -> list:
"""Walk all interval records in an IDFH file."""
intervals = []
# Multi-segment file: every 02 da 0a 00 00 00 marker introduces a segment.
# Single-interval file: just one body header at 0xf96 of form ?? ?? 0a 00 00 00.
# Find them all.
i = 0
while True:
j = buf.find(b"\x0a\x00\x00\x00", i)
if j < 0:
break
# Validate: the 2 bytes before must form a length, and we want bytes
# [j-2 : j+6] to have a recognisable shape. Actually the cleanest
# filter is "preceded by a length and followed by 00 NN 05 3f".
if j < 2:
i = j + 1
continue
# Body header form: [length_be_2][0a 00 00 00][00 NN][05 3f]
if j + 10 > len(buf):
break
length = int.from_bytes(buf[j-2:j], "big")
# Verify the segment-marker shape: [length_be][0a 00 00 00][00 NN][05 3f]
if buf[j+4] != 0x00:
i = j + 1
continue
if buf[j+6:j+8] != b"\x05\x3f":
i = j + 1
continue
# Header layout (10 bytes): [length_be 2B][0a 00 00 00 4B][00 NN 2B][05 3f 2B]
# Followed by N interval records of 72 bytes each, then 2 tail bytes.
# length value = (N × 72) + 10 (counts bytes from 0x0a... through interval data).
header_start = j - 2
n_intervals = (length - 10) // INTERVAL_SIZE
interval_start = header_start + 10
for k in range(n_intervals):
off = interval_start + k * INTERVAL_SIZE
if off + INTERVAL_SIZE > len(buf):
break
chunk = buf[off:off + INTERVAL_SIZE]
intervals.append({"offset": off, **decode_interval(chunk)})
i = header_start + length + 2
return intervals
def main():
# Test against multi-segment IDFH
target = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM13981/UM13981_20220805075441.IDFH"
sc_path = target.parent / "TXT" / f"{target.name}.txt"
buf = target.read_bytes()
intervals = walk_idfh(buf)
print(f"=== {target.name} ===")
print(f" file size: {len(buf)}")
print(f" decoded intervals: {len(intervals)}")
# Show first 2 + last 2
sc_rows = []
for line in sc_path.read_text(errors="replace").splitlines():
if line.startswith("2022-") or line.startswith("2023-"):
sc_rows.append(line)
print(f" sidecar rows: {len(sc_rows)}")
print()
for k in [0, 1, 78, 79, 80]:
if k >= len(intervals):
continue
iv = intervals[k]
print(f"--- interval {k} @0x{iv['offset']:04x} ---")
for ch in CHANNELS:
d = iv[ch]
peak_ips = d["peak"] / 32768 * 10.0
print(f" {ch}: peak={d['peak']:5d} ({peak_ips:.4f} in/s) halfp={d['halfp']:5d} freq={d['freq_hz']}")
# sidecar row
if k < len(sc_rows):
print(f" SC: {sc_rows[k]}")
# Test single-interval IDFH
print()
target2 = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM11719/UM11719_20231219162648.IDFH"
sc2 = target2.parent / "TXT" / f"{target2.name}.txt"
buf2 = target2.read_bytes()
intervals2 = walk_idfh(buf2)
print(f"=== {target2.name} ===")
print(f" file size: {len(buf2)}, decoded intervals: {len(intervals2)}")
if intervals2:
iv = intervals2[0]
for ch in CHANNELS:
d = iv[ch]
peak_ips = d["peak"] / 32768 * 10.0
print(f" {ch}: peak={d['peak']:5d} ({peak_ips:.4f} in/s) halfp={d['halfp']:5d} freq={d['freq_hz']}")
sc_rows2 = [l for l in sc2.read_text(errors='replace').splitlines() if l.startswith("2023-")]
if sc_rows2:
print(f" SC: {sc_rows2[0]}")
if __name__ == "__main__":
main()
-41
View File
@@ -1,41 +0,0 @@
"""Find IDFH interval period via auto-correlation of structural patterns."""
from __future__ import annotations
import sys
from pathlib import Path
from collections import Counter
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
def main():
target = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM13981/UM13981_20220805075441.IDFH"
buf = target.read_bytes()
body_start = 0xF96
body_end = 0x270C
body = buf[body_start:body_end]
print(f"body size: {len(body)} bytes (file {len(buf)} bytes)")
# For each candidate interval size, count how many bytes at fixed offsets within
# each interval are zero (consistent column-zero pattern indicates correct size).
print()
print("=== zero-column score by interval size (higher = more likely) ===")
best = []
for sz in range(16, 100):
n = len(body) // sz
if n < 30:
continue
# For each column position within an interval, count how many of n intervals have zero
score = 0
for col in range(sz):
zeros = sum(1 for i in range(n) if body[i*sz + col] == 0)
if zeros >= n * 0.9:
score += 1
best.append((score, sz, n))
best.sort(reverse=True)
for score, sz, n in best[:10]:
print(f" size={sz:3d} n_intervals={n} consistently-zero-cols={score}")
if __name__ == "__main__":
main()
-40
View File
@@ -1,40 +0,0 @@
"""Per-file accuracy + sample-count details."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from micromate.idf_file import read_idf_file
from analysis_idf.recon import load_sidecar_samples
def main():
root = REPO / "tests/fixtures/THORDATA_example"
files = sorted([f for f in root.rglob("*.IDFW") if not str(f).endswith(".CDB")])
GEO_LSB = 0.0003
# Limit to first 15 successful files for detail.
shown = 0
for f in files:
try:
res = read_idf_file(f)
except Exception:
continue
sc_path = f.parent / "TXT" / f"{f.name}.txt"
if not sc_path.exists():
continue
sc = load_sidecar_samples(sc_path)
sc_tran = [int(round(v / GEO_LSB)) for v in sc["Tran"]]
dec = res.samples.get("Tran", [])
n = min(len(sc_tran), len(dec))
exact = sum(1 for i in range(n) if sc_tran[i] == dec[i]) if n else 0
pct = 100.0 * exact / n if n else 0.0
print(f"{f.name:40s} size={f.stat().st_size:6d} sc_n={len(sc_tran):4d} dec_n={len(dec):4d} exact={pct:.1f}%")
shown += 1
if shown >= 20:
break
if __name__ == "__main__":
main()
-64
View File
@@ -1,64 +0,0 @@
"""Look at what's at the divergence boundary."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from minimateplus.waveform_codec import walk_body, find_data_start, parse_segment_header
from analysis_idf.recon import TARGET, TXT, load_sidecar_samples
def main():
buf = TARGET.read_bytes()
body = buf[0x0f1f:]
start = find_data_start(body)
print(f"data_start: {start} (= file offset 0x{0x0f1f + start:04x})")
blocks = walk_body(body, start)
print(f"{len(blocks)} blocks total")
print()
# First 25 blocks
print("=== first 30 blocks ===")
for i, b in enumerate(blocks[:30]):
body_off = 0x0f1f + b.offset
if b.tag_hi == 0x40:
hdr = parse_segment_header(b)
print(f" [{i:3d}] @0x{body_off:04x} {b.kind} (segment header) counter={hdr['counter'] if hdr else '?'} field2={hdr['field2'].hex() if hdr else '?'} anchor={hdr['anchor_bytes'].hex() if hdr else '?'} tail={hdr['tail'].hex() if hdr else '?'}")
else:
print(f" [{i:3d}] @0x{body_off:04x} {b.kind} len={b.length} data={b.data[:16].hex()}")
print()
# Cumulative sample counts per block to find which block contains sample 254
print("=== cumulative samples through blocks ===")
cur_ch = "Tran"
rotation = ["Vert", "Long", "MicL", "Tran"]
seg_count = 0
samples_in_curseg = 2 # preamble Tran[0], Tran[1]
for i, b in enumerate(blocks[:30]):
if b.tag_hi == 0x40:
seg_count += 1
prev_ch = cur_ch
cur_ch = rotation[(seg_count - 1) % 4]
print(f" [{i:3d}] 40 02 -> end of {prev_ch} segment, start {cur_ch} (segment {seg_count})")
samples_in_curseg = 2 # anchors
elif (b.tag_hi & 0xF0) == 0x10:
nn = ((b.tag_hi & 0x0F) << 8) | b.tag_lo
samples_in_curseg += nn
print(f" [{i:3d}] {b.kind} nibble: +{nn} samples, ch={cur_ch}, ch_total~{samples_in_curseg}")
elif (b.tag_hi & 0xF0) == 0x20:
nn = ((b.tag_hi & 0x0F) << 8) | b.tag_lo
samples_in_curseg += nn
print(f" [{i:3d}] {b.kind} int8: +{nn} samples, ch={cur_ch}, ch_total~{samples_in_curseg}")
elif b.tag_hi == 0x00:
samples_in_curseg += b.tag_lo
print(f" [{i:3d}] {b.kind} RLE: +{b.tag_lo}, ch={cur_ch}, ch_total~{samples_in_curseg}")
elif b.tag_hi == 0x30:
samples_in_curseg += b.tag_lo
print(f" [{i:3d}] {b.kind} packed12: +{b.tag_lo} samples, ch={cur_ch}, ch_total~{samples_in_curseg}")
if __name__ == "__main__":
main()
-89
View File
@@ -1,89 +0,0 @@
"""Reconnaissance helpers for cracking the Thor IDFW binary."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
TARGET = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM11719/UM11719_20231219162723.IDFW"
TXT = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM11719/TXT/UM11719_20231219162723.IDFW.txt"
def hex_at(buf: bytes, off: int, n: int = 32) -> str:
chunk = buf[off : off + n]
hexs = " ".join(f"{b:02x}" for b in chunk)
asc = "".join(chr(b) if 32 <= b < 127 else "." for b in chunk)
return f"{off:04x}: {hexs} {asc}"
def find_all(buf: bytes, needle: bytes) -> list[int]:
out: list[int] = []
i = 0
while True:
j = buf.find(needle, i)
if j < 0:
break
out.append(j)
i = j + 1
return out
def load_sidecar_samples(path: Path) -> dict[str, list[float]]:
"""Parse the txt sample table — Tran/Vert/Long/MicL."""
out = {"Tran": [], "Vert": [], "Long": [], "MicL": []}
in_block = False
for line in path.read_text(errors="replace").splitlines():
if not in_block:
if line.strip() == "Waveform Data Channels":
in_block = True
continue
if line.startswith("Waveform Data USB Channels"):
break
parts = line.split("\t")
# First row is the header "\tTran\tVert\tLong\tMicL"
if len(parts) >= 5 and parts[1] == "Tran":
continue
if len(parts) < 5:
continue
try:
out["Tran"].append(float(parts[1]))
out["Vert"].append(float(parts[2]))
out["Long"].append(float(parts[3]))
out["MicL"].append(float(parts[4]))
except ValueError:
continue
return out
def main():
buf = TARGET.read_bytes()
samples = load_sidecar_samples(TXT)
print(f"file size: {len(buf)} bytes")
print(f"sample rows: Tran={len(samples['Tran'])} Vert={len(samples['Vert'])} Long={len(samples['Long'])} MicL={len(samples['MicL'])}")
print(f"first 6 Tran samples: {samples['Tran'][:6]}")
print(f"first 6 Vert samples: {samples['Vert'][:6]}")
print(f"first 6 Long samples: {samples['Long'][:6]}")
print(f"first 6 MicL samples: {samples['MicL'][:6]}")
print()
print("=== BW magic '00 02 00' positions ===")
hits = find_all(buf, b"\x00\x02\x00")
print(f"{len(hits)} hits")
for h in hits[:20]:
print(hex_at(buf, h, 24))
print()
print("=== '40 02' segment-header positions ===")
hits = find_all(buf, b"\x40\x02")
print(f"{len(hits)} hits")
for h in hits:
ctx_pre = buf[max(0, h - 4): h].hex()
ctx_post = buf[h: h + 20].hex()
# Show byte preceding to help identify real headers vs casual occurrences
print(f" 0x{h:04x} pre={ctx_pre} post={ctx_post}")
if __name__ == "__main__":
main()
-40
View File
@@ -1,40 +0,0 @@
"""Find each segment boundary in the channel and check if errors reset there."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from minimateplus.waveform_codec import decode_waveform_v2
from analysis_idf.recon import TARGET, TXT, load_sidecar_samples
def main():
buf = TARGET.read_bytes()
sc = load_sidecar_samples(TXT)
decoded = decode_waveform_v2(buf[0x0f1f:])
GEO_LSB = 0.0003
for ch in ("Tran", "Vert", "Long"):
sc_counts = [int(round(v / GEO_LSB)) for v in sc[ch]]
dec = decoded[ch]
# Find every transition where error becomes zero from nonzero (or grows from zero)
# Print indices where dec resyncs back to exact match.
n = min(len(sc_counts), len(dec))
events = []
prev_match = True
for i in range(n):
match = sc_counts[i] == dec[i]
if match != prev_match:
kind = "RESYNC" if match else "DIVERGE"
events.append((i, kind, sc_counts[i], dec[i]))
prev_match = match
print(f"{ch}: {len(events)} transitions")
for i, kind, sc_v, dec_v in events[:20]:
print(f" idx {i:4d} {kind:8s} sc={sc_v:6d} dec={dec_v:6d} diff={dec_v-sc_v:+d}")
print()
if __name__ == "__main__":
main()
-46
View File
@@ -1,46 +0,0 @@
"""Smoke-test read_idf_file on IDFH across the corpus."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from micromate.idf_file import read_idf_file
def main():
target = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM11719/UM11719_20231219162648.IDFH"
result = read_idf_file(target)
ev = result.event
print(f"=== {target.name} ===")
print(f" signature: {result.signature}")
print(f" serial: {ev.serial}")
print(f" timestamp: {ev.timestamp}")
print(f" sample_rate: {ev.sample_rate}")
print(f" kind: {ev.kind}")
print(f" intervals: {len(result.intervals or [])}")
print(f" peaks: T={ev.peaks.transverse_ips:.4f} V={ev.peaks.vertical_ips:.4f} L={ev.peaks.longitudinal_ips:.4f}")
print()
root = REPO / "tests/fixtures/THORDATA_example"
files = list(root.rglob("*.IDFH"))
ok = fail = nyi = 0
total_intervals = 0
for f in files:
try:
r = read_idf_file(f)
ok += 1
total_intervals += len(r.intervals or [])
except NotImplementedError:
nyi += 1
except Exception as exc:
fail += 1
if fail <= 3:
print(f" FAIL: {f.name}: {type(exc).__name__}: {exc}")
print(f"Corpus: {len(files)} IDFH files | ok={ok} fail={fail} nyi={nyi}")
print(f"Total intervals decoded: {total_intervals}")
if __name__ == "__main__":
main()
-48
View File
@@ -1,48 +0,0 @@
"""Smoke-test read_idf_file across the sample corpus."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from micromate.idf_file import read_idf_file, geo_count_to_ips, mic_count_to_psi
def main():
target = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM11719/UM11719_20231219162723.IDFW"
result = read_idf_file(target)
ev = result.event
print(f"=== {target.name} ===")
print(f" signature: {result.signature}")
print(f" serial: {ev.serial}")
print(f" timestamp: {ev.timestamp}")
print(f" sample_rate: {ev.sample_rate}")
print(f" record_time: {ev.record_time_sec}")
print(f" calibration: {result.binary_metadata.calibration_date}")
print(f" Tran samples: {len(result.samples['Tran'])}, peak_ips={ev.peaks.transverse_ips:.4f}")
print(f" Vert samples: {len(result.samples['Vert'])}, peak_ips={ev.peaks.vertical_ips:.4f}")
print(f" Long samples: {len(result.samples['Long'])}, peak_ips={ev.peaks.longitudinal_ips:.4f}")
print(f" MicL samples: {len(result.samples['MicL'])}")
print()
# Corpus sweep
root = REPO / "tests/fixtures/THORDATA_example"
files = [f for f in root.rglob("*.IDFW") if not str(f).endswith(".CDB")]
ok = fail = nyi = 0
for f in files:
try:
r = read_idf_file(f)
ok += 1
except NotImplementedError:
nyi += 1
except Exception as exc:
fail += 1
if fail <= 5:
print(f" FAIL: {f.name}: {type(exc).__name__}: {exc}")
print()
print(f"Corpus: {len(files)} IDFW files | ok={ok} fail={fail} not-implemented={nyi}")
if __name__ == "__main__":
main()
-47
View File
@@ -1,47 +0,0 @@
"""Verify build_bw_report_from_idf against a known sidecar."""
from __future__ import annotations
import json
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from micromate.idf_ascii_report import parse_idf_report
from micromate.idf_to_bw_report import build_bw_report_from_idf
from micromate.idf_file import read_idf_file
def show(prefix: str, d: dict, indent: int = 0):
for k, v in d.items():
if isinstance(v, dict):
print(f"{' '*indent}{prefix}{k}:")
show("", v, indent + 1)
else:
print(f"{' '*indent}{prefix}{k}: {v!r}")
def main():
base = REPO / "tests/fixtures/THORDATA_example/THORDATA_example/UPMC Presby/UM11719"
idfw = base / "UM11719_20231219162723.IDFW"
txt = base / "TXT" / f"{idfw.name}.txt"
report_dict = parse_idf_report(txt.read_text(errors="replace"))
res = read_idf_file(idfw)
bw = build_bw_report_from_idf(report_dict, binary_md=res.binary_metadata)
print("=== IDFW → bw_report ===")
show("", bw)
print()
print("=== IDFH (single trigger row) ===")
idfh = base / "UM11719_20231219162648.IDFH"
txt_h = base / "TXT" / f"{idfh.name}.txt"
rh = parse_idf_report(txt_h.read_text(errors="replace"))
res_h = read_idf_file(idfh)
bw_h = build_bw_report_from_idf(rh, binary_md=res_h.binary_metadata, intervals=res_h.intervals)
show("", bw_h)
if __name__ == "__main__":
main()
Binary file not shown.
Binary file not shown.
-73
View File
@@ -1,73 +0,0 @@
"""Trace Tran sample-by-sample to find exactly where the codec drifts."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from analysis_idf.recon import TARGET, TXT, load_sidecar_samples
def s4(n: int) -> int:
return n if n < 8 else n - 16
def i8(b: int) -> int:
return b if b < 128 else b - 256
def main():
buf = TARGET.read_bytes()
sc = load_sidecar_samples(TXT)
GEO_LSB = 0.0003
sc_tran = [int(round(v / GEO_LSB)) for v in sc["Tran"]]
body = buf[0x0f1f:]
# Tran[0], Tran[1] from preamble
t0 = int.from_bytes(body[3:5], "big", signed=True)
t1 = int.from_bytes(body[5:7], "big", signed=True)
print(f"preamble Tran[0]={t0} Tran[1]={t1} (sidecar: {sc_tran[0]}, {sc_tran[1]})")
# Block 0: 10 f8 at body[7:9]
print(f"block 0: tag {body[7]:02x} {body[8]:02x}")
print(f" block 0 first 10 data bytes: {body[9:19].hex()}")
# Walk block 0 manually, comparing each sample
cur = t1
samples = [t0, t1]
block_off = 7
nn = body[8]
print(f" NN = {nn}")
data = body[9 : 9 + nn // 2]
for byi, byte in enumerate(data):
for nib_idx, nib in enumerate(((byte >> 4) & 0xF, byte & 0xF)):
cur += s4(nib)
samples.append(cur)
idx = len(samples) - 1
if 0 <= idx < len(sc_tran):
sc_v = sc_tran[idx]
match = "✓" if sc_v == cur else "✗"
if idx < 12 or 240 <= idx <= 260:
print(f" idx {idx:3d}: nibble byte={byte:02x} nib={nib:x} delta={s4(nib):+d} cur={cur:+d} sc={sc_v:+d} {match}")
print(f"end of block 0: cur={cur}, len(samples)={len(samples)}, decoder expected 250 here")
# Block 1: 20 28 starts at offset 9 + 124 = 133 from block_off=7
block1_off = 9 + nn // 2
print(f"block 1: tag {body[block1_off]:02x} {body[block1_off+1]:02x} (expecting 20 28)")
nn1 = body[block1_off + 1]
print(f" block 1 NN = {nn1}")
data1 = body[block1_off + 2 : block1_off + 2 + nn1]
for byi, byte in enumerate(data1):
cur += i8(byte)
samples.append(cur)
idx = len(samples) - 1
if idx < len(sc_tran):
sc_v = sc_tran[idx]
match = "✓" if sc_v == cur else "✗"
if 248 <= idx <= 295:
print(f" idx {idx:3d}: int8 byte={byte:02x} delta={i8(byte):+d} cur={cur:+d} sc={sc_v:+d} {match}")
if __name__ == "__main__":
main()
-42
View File
@@ -1,42 +0,0 @@
"""Feed candidate body offsets to the BW codec and compare with sidecar."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from minimateplus.waveform_codec import decode_waveform_v2, walk_body, find_data_start
from analysis_idf.recon import TARGET, TXT, load_sidecar_samples
def main():
buf = TARGET.read_bytes()
sc = load_sidecar_samples(TXT)
# Sidecar samples in 0.0003 counts (Thor geo LSB).
sc_tran = [int(round(v / 0.0003)) for v in sc["Tran"][:30]]
sc_vert = [int(round(v / 0.0003)) for v in sc["Vert"][:30]]
sc_long = [int(round(v / 0.0003)) for v in sc["Long"][:30]]
sc_micl = [int(round(v / 1e-6)) for v in sc["MicL"][:30]] # 1 µ unit for mic? Will iterate.
print(f"sidecar Tran (counts): {sc_tran}")
print(f"sidecar Vert (counts): {sc_vert}")
print(f"sidecar Long (counts): {sc_long}")
print(f"sidecar MicL (×1e-6): {sc_micl}")
print()
# Try candidate body start offsets.
for off in (0x0f1f, 0x1057, 0x11f1, 0x1333, 0x1bde, 0x0d30):
print(f"=== body @ 0x{off:04x} ===")
body = buf[off:]
decoded = decode_waveform_v2(body)
if not decoded:
print(" decode_waveform_v2 returned None")
continue
for ch in ("Tran", "Vert", "Long", "MicL"):
arr = decoded.get(ch, [])
print(f" {ch}[{len(arr)}]: {arr[:20]}")
print()
if __name__ == "__main__":
main()
-51
View File
@@ -1,51 +0,0 @@
"""Verify decode_waveform_v2 against sidecar across all 2304 samples per channel."""
from __future__ import annotations
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parents[1]
sys.path.insert(0, str(REPO))
from minimateplus.waveform_codec import decode_waveform_v2
from analysis_idf.recon import TARGET, TXT, load_sidecar_samples
def main():
buf = TARGET.read_bytes()
sc = load_sidecar_samples(TXT)
body = buf[0x0f1f:]
decoded = decode_waveform_v2(body)
print(f"Sidecar lengths: Tran={len(sc['Tran'])} Vert={len(sc['Vert'])} Long={len(sc['Long'])} MicL={len(sc['MicL'])}")
print(f"Decoded lengths: Tran={len(decoded['Tran'])} Vert={len(decoded['Vert'])} Long={len(decoded['Long'])} MicL={len(decoded['MicL'])}")
print()
GEO_LSB = 0.0003 # in/s per count
for ch in ("Tran", "Vert", "Long"):
sc_counts = [int(round(v / GEO_LSB)) for v in sc[ch]]
dec = decoded[ch]
n = min(len(sc_counts), len(dec))
matches = sum(1 for i in range(n) if sc_counts[i] == dec[i])
first_mismatch = next((i for i in range(n) if sc_counts[i] != dec[i]), None)
print(f"{ch}: compared {n}, exact matches {matches} ({100*matches/n:.2f}%)")
if first_mismatch is not None:
i = first_mismatch
print(f" first mismatch at idx {i}: sidecar={sc_counts[i]} ({sc[ch][i]}), decoded={dec[i]}")
print(f" context sidecar[{i-2}..{i+5}]: {sc_counts[max(0,i-2):i+5]}")
print(f" context decoded[{i-2}..{i+5}]: {dec[max(0,i-2):i+5]}")
# MicL: find the multiplicative factor that fits
print()
print("=== MicL scale analysis ===")
sc_micl = sc["MicL"]
dec_micl = decoded["MicL"]
# Skip zero values when computing ratio
ratios = [sc_micl[i] / dec_micl[i] for i in range(min(50, len(sc_micl), len(dec_micl))) if dec_micl[i] != 0]
if ratios:
avg = sum(ratios) / len(ratios)
print(f" avg ratio sidecar/decoded over first 50 nonzero: {avg:.4e} (n={len(ratios)})")
print(f" ratios sample: {[f'{r:.4e}' for r in ratios[:6]]}")
if __name__ == "__main__":
main()
-76
View File
@@ -177,8 +177,6 @@ class AchSession:
store: "WaveformStore",
clear_after_download: bool = False,
restart_monitoring: bool = False,
rescue_stop_monitoring: bool = False,
rescue_disable_ach: bool = False,
force_redownload: bool = False,
) -> None:
self.sock = sock
@@ -192,9 +190,6 @@ class AchSession:
self.store = store
self.clear_after_download = clear_after_download
self.restart_monitoring = restart_monitoring
# Rescue actions for a runaway unit — fired before the event walk.
self.rescue_stop_monitoring = rescue_stop_monitoring
self.rescue_disable_ach = rescue_disable_ach
# `force_redownload` tells this session to ignore ach_state and
# re-download every event currently on the device, regardless of any
# (key, timestamp) match. Useful as a manual override when state has
@@ -295,41 +290,6 @@ class AchSession:
root_logger.addHandler(fh)
try:
# ── Step 1.5: rescue actions ──────────────────────────────────────
# Fired BEFORE the event walk so a runaway unit is quieted as early
# in the session as possible. A unit whose geophone sits above the
# trigger threshold records back-to-back and, with ACH set to "after
# event recorded", re-dials every time — saturating its own firmware
# so it never services inbound requests. See
# docs/runbooks/wedged_unit_recovery.md.
#
# Each action is independently guarded: a failure here must not
# abort the download that follows.
if self.rescue_stop_monitoring or self.rescue_disable_ach:
rescue: dict = {"peer": self.peer, "ts": ts}
if self.rescue_stop_monitoring:
log.info("Step 1.5: RESCUE — stop monitoring (SUB 0x97)")
try:
client.stop_monitoring()
rescue["stop_monitoring"] = "ok"
log.info(" stop monitoring OK — device should stop recording")
except Exception as exc:
rescue["stop_monitoring"] = f"failed: {exc}"
log.error(" stop monitoring FAILED: %s", exc)
if self.rescue_disable_ach:
log.info("Step 1.5: RESCUE — disable auto call home (SUB 0x2C/0x7E/0x7F)")
try:
client.set_call_home_config(auto_call_home_enabled=False)
rescue["disable_ach"] = "ok"
log.info(" disable ACH OK — unit should stop calling home")
except Exception as exc:
rescue["disable_ach"] = f"failed: {exc}"
log.error(" disable ACH FAILED: %s", exc)
_save_json(session_dir / "rescue.json", rescue)
# ── Step 2: device info ───────────────────────────────────────────
device_info = None
if not self.events_only:
@@ -556,7 +516,6 @@ class AchSession:
serial=serial or self.peer,
session_id=None,
waveform_records=waveform_records,
device_family="series3",
)
_ml_ins, _ml_skip = self.db.insert_monitor_log(
new_monitor_entries, session_id=None
@@ -787,13 +746,6 @@ def serve(args: argparse.Namespace) -> None:
print(f" Max events per session: {max_ev if max_ev else 'unlimited'}")
print(f" Clear device after download: {'YES' if args.clear_after_download else 'no'}")
print(f" Restart monitoring after download: {'YES' if args.restart_monitoring else 'no'}")
_stop_mon = args.stop_monitoring or args.rescue
_dis_ach = args.disable_ach or args.rescue
print(f" RESCUE stop monitoring on connect: {'YES' if _stop_mon else 'no'}")
print(f" RESCUE disable auto call home: {'YES' if _dis_ach else 'no'}")
if _stop_mon and args.restart_monitoring:
print(" !! --restart-monitoring will re-start the unit after download,")
print(" undoing --stop-monitoring. Drop one of them.")
print(f" Force re-download all (ignore state): {'YES' if args.force_redownload_all else 'no'}")
print(f"{'='*60}")
print(f"\n Point your test unit's ACEmanager call-home settings to:")
@@ -835,8 +787,6 @@ def serve(args: argparse.Namespace) -> None:
store=store,
clear_after_download=args.clear_after_download,
restart_monitoring=args.restart_monitoring,
rescue_stop_monitoring=args.stop_monitoring or args.rescue,
rescue_disable_ach=args.disable_ach or args.rescue,
force_redownload=args.force_redownload_all,
)
t = threading.Thread(target=session.run, daemon=True, name=f"ach-{peer}")
@@ -911,32 +861,6 @@ def parse_args() -> argparse.Namespace:
"DCD on disconnect — without this the unit stays idle after a call-home."
),
)
p.add_argument(
"--stop-monitoring",
action="store_true",
default=False,
help=(
"RESCUE: send SUB 0x97 (stop monitoring) immediately after the "
"handshake, before any event download. Use on a unit that is "
"recording back-to-back because of a stuck-triggered geophone."
),
)
p.add_argument(
"--disable-ach",
action="store_true",
default=False,
help=(
"RESCUE: disable Auto Call Home on the device (SUB 0x2C read → "
"0x7E write → 0x7F confirm) immediately after the handshake. The "
"unit stops dialing out until ACH is explicitly re-enabled."
),
)
p.add_argument(
"--rescue",
action="store_true",
default=False,
help="Shorthand for --stop-monitoring --disable-ach.",
)
p.add_argument(
"--clear-after-download",
action="store_true",
-398
View File
@@ -1,398 +0,0 @@
#!/usr/bin/env python3
"""
mm_ach_server.py — inbound Auto Call Home server for Micromate (Series IV).
**Read-only.** It identifies the unit, reads its state and setups, and walks the
event chain. It does not erase, does not write, does not start or stop
monitoring, and downloads nothing unless asked. Series III's `ach_server.py`
has "rescue actions" that quiet a runaway unit; those are deliberately absent
here, because no command has ever been originated against a unit by this project
and an inbound session is the worst place to break that.
What this is for
----------------
The inbound call-home session is the last unmapped part of the Series IV
protocol.
⚠ **No Micromate has ever been observed calling home.** The 72 `ach_inbound_*`
sessions in `bridges/captures/` are **MiniMate Plus**, and the Series III setup
does not automatically transfer. What we have for Series IV is prior, not
observation:
* The THOR manual §6.2 and the firmware's own strings
(`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING`, `Call Home Deleting
Events`) say the unit dials in and then **waits to be told what to do** —
server-driven, the same shape as Series III's pull model.
* UM12947's `0x2C` dial string reads literally `"RADIO RING"`, which is modem
*answer* vocabulary rather than a destination. With the RV50 debug string
`ATQ1 ATE0 ATS0=2 … RADIO RING` — `ATS0=2` being auto-answer-after-2-rings —
that reads as the unit configuring the modem to **accept** calls, i.e. the
call-*up* path. Which suggests the ACH destination lives in the **modem**,
as it does for Series III.
**If both priors hold, this file is just `MicromateClient` on an inbound socket
and the unknown evaporates.** But there is a specific way it can fail:
⚠ **Those AT strings prove the Micromate talks to the modem over serial.** If it
drives an AT dial for call-home, that exchange happens on the **serial link**,
where a TCP listener sees nothing whatsoever. So a null result here is
informative but ambiguous — it means *either* the trigger did not fire *or* the
interesting part is happening somewhere this tool cannot watch. **If nothing
arrives, the next step is a serial-level capture between the unit and the modem,
not more fiddling with this server.**
**The one question that matters is push vs pull**, and it cannot be answered by
sniffing — only by connecting and keeping quiet. So this server **says nothing
for `--grace` seconds** after accepting. If bytes arrive in that window the unit
speaks first (push) and the server reports exactly what it sent. If the window
passes in silence, it is pull, and the normal handshake follows.
Setup
-----
1. Run this where the unit can reach it:
python3 bridges/mm_ach_server.py --port 12345
2. Point the call-home destination at this machine. **For Series III that
lived in the MODEM's config (ACEmanager), not in the seismograph** — so try
AirLink OS first. If the RX55 can be told to open an outbound TCP session
to `<your IP>:12345` on serial activity, nothing on the instrument needs to
change, which is much the better outcome.
If it has to come from the unit instead, its `SUB 0x2C` call-home block
holds a 40-byte dial string — but **writing that is THOR's job, not ours.**
3. Trigger a call. A scheduled time is the controllable option: repeatable,
needs no monitoring and no thumping. An event-triggered call is the more
interesting session, because it shows how an event gets offered.
4. Watch. Every frame is decoded as it arrives.
⚠ Use a bench unit. Changing a call-home destination means a unit stops
reporting to THOR until it is changed back.
Output per session, in the layout `scratch/mm_frame_parse.py` reads directly:
bridges/captures/mm_ach_<ts>/
raw_bw_<ts>.bin us → unit
raw_s3_<ts>.bin unit → us
session_<ts>.log
session.json what we learned, including push-vs-pull
"""
from __future__ import annotations
import argparse
import datetime
import json
import logging
import socket
import sys
import threading
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from micromate.client import MicromateClient # noqa: E402
from micromate.framing import MicromateFrameParser # noqa: E402
from micromate.protocol import ProtocolError # noqa: E402
from minimateplus.transport import SocketTransport # noqa: E402
log = logging.getLogger("mm_ach")
DEPTHS = ("identify", "state", "events", "download")
# Strings the MODEM puts on the wire, which are not the unit talking.
#
# `CLAUDE.md` already records that an RV50/RV55 "sends \r\nRING\r\n\r\nCONNECT\r\n
# over TCP to the caller even with Quiet Mode enabled". An RX55 on AirLink OS
# says `RADIO RING` instead, space-padded and newline-separated. Observed
# 2026-10-14 from UM12947's modem: four of them and **no CONNECT**.
#
# ⚠ The absence of CONNECT is the useful part. RING means the modem is ringing
# the serial device; CONNECT means something answered. Rings without a CONNECT,
# and no answer to POLL, means the TCP side is fine and the UNIT is not on the
# other end of the serial link.
_MODEM_CHATTER = (b"RADIO RING", b"RING", b"CONNECT", b"NO CARRIER", b"BUSY",
b"NO ANSWER", b"ERROR", b"OK")
class Session:
"""One inbound call. Captures every byte; decides push vs pull first."""
def __init__(self, sock: socket.socket, peer: str, args) -> None:
self.sock, self.peer, self.args = sock, peer, args
self.ts = datetime.datetime.now().strftime("%Y%m%d_%H%M%S")
self.found: dict = {"peer": peer, "started": self.ts}
self._rx: list[bytes] = []
self._tx: list[bytes] = []
self._rx_fh = self._tx_fh = None
# ── byte taps ─────────────────────────────────────────────────────────────
def _tap(self, transport) -> None:
"""Mirror every byte, buffered until we know this is a real unit."""
orig_read, orig_write = transport.read, transport.write
def read(n: int) -> bytes:
data = orig_read(n)
if data:
(self._rx_fh.write(data), self._rx_fh.flush()) if self._rx_fh \
else self._rx.append(data)
return data
def write(data: bytes) -> None:
orig_write(data)
if data:
(self._tx_fh.write(data), self._tx_fh.flush()) if self._tx_fh \
else self._tx.append(data)
transport.read, transport.write = read, write
def _open_capture(self) -> Path:
"""Create the session directory — only once we trust the peer.
A port scanner should leave nothing on disk.
"""
d = Path(self.args.output) / f"mm_ach_{self.ts}"
d.mkdir(parents=True, exist_ok=True)
# Named raw_bw/raw_s3 so scratch/mm_frame_parse.py reads the pair as-is.
self._tx_fh = open(d / f"raw_bw_{self.ts}.bin", "wb")
self._rx_fh = open(d / f"raw_s3_{self.ts}.bin", "wb")
for c in self._tx:
self._tx_fh.write(c)
for c in self._rx:
self._rx_fh.write(c)
self._tx_fh.flush()
self._rx_fh.flush()
self._tx.clear()
self._rx.clear()
return d
# ── the experiment ────────────────────────────────────────────────────────
def _listen_first(self, transport) -> bytes:
"""Say nothing for `--grace` seconds — unless a RING arrives.
Originally this just answered "does the unit speak first?". THOR's ACH
log (2026-10-14) made the question sharper: on seeing `RADIO RING` it
replies in **36 ms**, and with `ReadSerialNumber`, not `POLL`.
We were doing neither — sitting silent for the full 8 s and then sending
POLL. The unit may well have given up long before we spoke. So the
grace window now **ends the moment a ring is seen**, and the caller
answers it the way THOR does.
"""
print(f" listening in silence for up to {self.args.grace:.1f} s "
f"(ends early on a RING)...")
deadline = time.monotonic() + self.args.grace
got = bytearray()
while time.monotonic() < deadline:
chunk = transport.read(4096)
if chunk:
got += chunk
if b"RING" in got:
print(f" RING seen after "
f"{self.args.grace - (deadline - time.monotonic()):.2f} s"
f" — answering immediately, as THOR does")
return bytes(got)
else:
time.sleep(0.02)
return bytes(got)
def run(self) -> None:
print(f"\n=== inbound from {self.peer} at {self.ts} ===")
transport = SocketTransport(self.sock, peer=self.peer)
self._tap(transport)
unsolicited = self._listen_first(transport)
self.found["push"] = bool(unsolicited)
self.found["unsolicited_bytes"] = len(unsolicited)
if unsolicited:
print(f" ** PUSH ** — the unit sent {len(unsolicited)} B unprompted")
print(f" hex : {unsolicited[:64].hex(' ')}")
txt = "".join(chr(c) if 32 <= c < 127 else "." for c in unsolicited[:64])
print(f" ascii : |{txt}|")
hits = [c.decode() for c in _MODEM_CHATTER if c in unsolicited]
if hits:
rings = unsolicited.count(b"RING")
print(f" *** MODEM CHATTER, not the unit: {hits} ***")
self.found["modem_chatter"] = hits
self.found["ring_count"] = rings
if rings and b"CONNECT" not in unsolicited:
print(f" *** {rings} RING(s) and NO CONNECT. ***")
print(" The modem is ringing the serial device and nothing")
print(" is answering. TCP is fine; the UNIT is not on the")
print(" other end of the serial link. Check, in order:")
print(" 1. is the unit cabled to the modem at all?")
print(" 2. cable chipset -- FTDI (0403) or CDC-ACM only,")
print(" never Prolific (067b)")
print(" 3. cold-boot the unit WITH the cable attached;")
print(" its USB-A host port only enumerates at power-on")
self.found["diagnosis"] = "rings without connect: unit not on serial"
frames = MicromateFrameParser().feed(unsolicited)
if frames:
for f in frames:
print(f" frame : SUB=0x{f.sub:02x} "
f"(answers 0x{f.request_sub:02x}) {len(f.data)} B data, "
f"flags=0x{f.flags:02x}, chk "
f"{'ok' if f.checksum_valid else 'BAD'}")
self.found["unsolicited_subs"] = [f"0x{f.sub:02x}" for f in frames]
else:
print(" frame : none parsed — not a response frame. Could be")
print(" a banner (series III sends 'Operating System'")
print(" on cold boot) or a greeting we have not seen.")
else:
print(" ** PULL ** — silence. The unit is waiting to be driven,")
print(" same as series III. Running the normal handshake.")
# From here on it is the ordinary client, which is the point.
mm = MicromateClient(transport, recv_timeout=self.args.timeout)
try:
if b"RING" in unsolicited:
# ⚠ Answer a ring the way THOR does: SERIAL first, not POLL.
# THOR's ACH log shows ReadSerialNumber 36 ms after detecting the
# ring -- it is identifying which unit rang before doing anything
# else. Our POLL-after-8-seconds may simply have been too late
# and the wrong question.
print(" answering the ring with SERIAL (THOR's first move)...")
serial = _cstring(_content(mm.protocol.read_serial()))
print(f" *** THE UNIT ANSWERED: {serial} ***")
self.found["answered_ring"] = True
self.found["ring_serial"] = serial
info = mm.connect()
except ProtocolError as e:
print(f" handshake FAILED: {type(e).__name__}: {e}")
if not unsolicited:
print(" Nothing unprompted AND no answer to POLL — so this is")
print(" neither push nor pull as we understand it. The raw")
print(" capture is the thing to look at; keep it.")
self._finish(self._open_capture())
return
d = self._open_capture()
print(f" {info}")
self.found["device"] = {
"serial": info.serial, "model": info.model,
"firmware_line": info.firmware_line, "monitoring": info.monitoring,
"active_setup": info.active_setup,
}
try:
if DEPTHS.index(self.args.depth) >= DEPTHS.index("state"):
st = mm.get_state()
print(f" {st}")
self.found["state"] = {
"monitoring": st.monitoring,
"device_time": st.device_time.isoformat() if st.device_time else None,
"battery_volts": st.battery_volts,
"memory_free_bytes": st.memory_free_bytes,
}
self.found["setups"] = mm.list_setups()
print(f" {len(self.found['setups'])} setups")
if DEPTHS.index(self.args.depth) >= DEPTHS.index("events"):
refs = mm.list_events()
print(f" {len(refs)} events")
self.found["events"] = []
for r in refs:
print(f" {r}")
self.found["events"].append({
"uid": r.uid, "key": r.key_hex, "size": r.size,
"type": r.record_type, "filename": r.filename,
"timestamp": r.timestamp.isoformat() if r.timestamp else None,
"pvs_ips": r.peak_vector_sum_ips,
})
if self.args.depth == "download":
# Bounded on purpose: an unknown session is a poor place to
# discover that a 70 KB pull takes 30 s and the unit hung up.
for r in refs[: self.args.max_events]:
blob = mm.download_event(r)
out = d / (r.filename or f"{r.key_hex}.bin")
out.write_bytes(blob)
print(f" saved {out.name} ({len(blob)} B)")
except ProtocolError as e:
print(f" session ended early: {type(e).__name__}: {e}")
self.found["error"] = f"{type(e).__name__}: {e}"
self._finish(d)
def _finish(self, d: Path) -> None:
for fh in (self._rx_fh, self._tx_fh):
if fh:
fh.close()
(d / "session.json").write_text(json.dumps(self.found, indent=2))
try:
self.sock.close()
except OSError:
pass
print(f" saved {d}")
print(f" parse with: python3 scratch/mm_frame_parse.py {d}")
def main() -> int:
ap = argparse.ArgumentParser(
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
)
ap.add_argument("--port", type=int, default=12345)
ap.add_argument("--bind", default="0.0.0.0")
ap.add_argument("--output", default="bridges/captures")
ap.add_argument("--timeout", type=float, default=30.0,
help="per-command receive timeout; generous, because an "
"inbound cellular session is the slow case")
ap.add_argument("--grace", type=float, default=5.0,
help="seconds to stay SILENT after accepting, to see whether "
"the unit speaks first. This is the experiment; do not "
"set it to 0 on a first run.")
ap.add_argument("--depth", choices=DEPTHS, default="events",
help="how far to take the session. 'events' walks the chain "
"without downloading (default); 'download' also fetches "
"events, which on cellular is ~0.21 s + bytes/2350 each")
ap.add_argument("--max-events", type=int, default=3,
help="with --depth download, how many to fetch")
ap.add_argument("--once", action="store_true",
help="exit after the first session instead of listening on")
a = ap.parse_args()
# ⚠ Without this, stdout is block-buffered whenever it is not a terminal,
# so the live session commentary sits in a buffer and the log looks EMPTY
# while a call is happening. That cost a confusing few minutes on the first
# real call-in: the session was on disk but nothing was on screen.
try:
sys.stdout.reconfigure(line_buffering=True)
except AttributeError: # pragma: no cover - py<3.7
pass
logging.basicConfig(level=logging.INFO,
format="%(asctime)s %(levelname)-7s %(message)s")
srv = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
srv.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
srv.bind((a.bind, a.port))
srv.listen(5)
print(f"\nMicromate ACH server on {a.bind}:{a.port} (READ-ONLY)")
print(f" depth={a.depth} grace={a.grace}s timeout={a.timeout}s")
print(" waiting for a unit to call in. Ctrl-C to stop.\n")
try:
while True:
sock, addr = srv.accept()
peer = f"{addr[0]}:{addr[1]}"
s = Session(sock, peer, a)
if a.once:
s.run()
return 0
threading.Thread(target=s.run, daemon=False).start()
except KeyboardInterrupt:
print("\nstopped")
return 0
finally:
srv.close()
if __name__ == "__main__":
raise SystemExit(main())
-476
View File
@@ -1,476 +0,0 @@
#!/usr/bin/env python3
"""
mm_client_check.py — exercise the Micromate read client against a real unit.
**Read-only.** It sends POLL, SERIAL, state, monitor status, the setup walk and
(optionally) one event download. It never writes, never erases, never starts or
stops monitoring.
Why it exists
-------------
`micromate/{framing,protocol,client}.py` are verified against captures taken
**over USB**, on **one firmware line** (`11.0CB`). Two things that cannot be
verified that way:
* **the modem path.** An RX55/RV55 bridges serial to TCP transparently, but
it buffers up to ~1 s before forwarding, so a single logical response can
arrive as many small reads. The client reads to frame completion rather
than using idle-gap detection, which should be strictly more robust — but
"should be" is the point of this script.
* **the other firmware line.** `11.0BD` reports `flags = 0x03`, a shorter
model string, and a `SUB 0x1C` block 4 bytes longer. Inferred from a
2026-09-23 sweep; **confirmed on UM20147 2026-09-30** (forward offsets read
a correct battery and clock).
Run it over both paths and diff the two reports. Anything that differs beyond
timings is a finding.
Usage
-----
# over the modem
python3 bridges/mm_client_check.py 63.45.161.30:9034
# over USB / direct serial
python3 bridges/mm_client_check.py /dev/ttyACM0 --baud 115200
# include one event download (still read-only)
python3 bridges/mm_client_check.py <target> --download
⚠ These modems bridge ONE TCP session to serial at a time. If THOR holds the
unit, this will connect and then see nothing — that is contention, not a fault.
`bridges/mm_probe.py` explains that case; disconnect THOR first.
"""
from __future__ import annotations
import argparse
import errno
import os
import select
import sys
import termios
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from micromate.client import MicromateClient, _content # noqa: E402
from micromate.protocol import CHUNK_SIZE, ProtocolError # noqa: E402
from minimateplus.transport import TcpTransport # noqa: E402
class StdlibSerial:
"""Raw serial on stdlib `termios` — no pyserial.
`minimateplus.SerialTransport` needs pyserial, and a bench host is whatever
is to hand. On a PEP 668 distro (Mint 22, Ubuntu 24.04, Debian 12) a plain
`pip install pyserial` is refused outright, so a diagnostic that depends on
it is one you cannot run at the moment you need it. `bridges/mm_link.py`
and `scratch/fake_unit.py` already take this approach; this is the same
~30 lines, and it means the tool runs on a stock Python 3 anywhere.
Not a general replacement for SerialTransport — no flow control, no
parity options, Linux/macOS only. Enough for a Micromate, which is 8N1
with no handshaking.
"""
_BAUD = {9600: termios.B9600, 19200: termios.B19200, 38400: termios.B38400,
57600: termios.B57600, 115200: termios.B115200}
def __init__(self, path: str, baud: int = 115200) -> None:
if baud not in self._BAUD:
raise ValueError(f"unsupported baud {baud}; pick from {sorted(self._BAUD)}")
self.path, self.baud, self.fd = path, baud, None
def connect(self) -> None:
if self.fd is not None:
return
self.fd = os.open(self.path, os.O_RDWR | os.O_NOCTTY | os.O_NONBLOCK)
a = termios.tcgetattr(self.fd)
a[0] = a[1] = a[3] = 0 # raw in/out, non-canonical
a[2] = termios.CS8 | termios.CREAD | termios.CLOCAL # 8N1, ignore modem lines
a[4] = a[5] = self._BAUD[self.baud]
a[6] = list(a[6])
a[6][termios.VMIN] = 0
a[6][termios.VTIME] = 0
termios.tcsetattr(self.fd, termios.TCSANOW, a)
termios.tcflush(self.fd, termios.TCIOFLUSH)
def disconnect(self) -> None:
if self.fd is not None:
os.close(self.fd)
self.fd = None
def is_connected(self) -> bool:
return self.fd is not None
def read(self, n: int) -> bytes:
if self.fd is None:
return b""
r, _, _ = select.select([self.fd], [], [], 0.05)
if not r:
return b""
try:
return os.read(self.fd, n)
except OSError as e:
if e.errno in (errno.EAGAIN, errno.EWOULDBLOCK):
return b""
raise
def write(self, data: bytes) -> None:
if self.fd is None:
raise OSError("port is not open")
while data:
data = data[os.write(self.fd, data):]
class _Timed:
"""Count bytes and time each read, so the two transports can be compared.
With `capture`, also writes the raw byte streams to a `raw_bw_*` /
`raw_s3_*` pair in the layout `scratch/mm_frame_parse.py` already reads --
so a run on an unfamiliar unit can be turned into test fixtures without
setting up a relay.
"""
def __init__(self, inner, capture: str | None = None) -> None:
self._inner = inner
self.reads = 0
self.bytes_in = 0
self.bytes_out = 0
self._bw = self._s3 = None
if capture:
stamp = time.strftime("%Y%m%d_%H%M%S")
d = Path(capture)
d.mkdir(parents=True, exist_ok=True)
self.bw_path = d / f"raw_bw_{stamp}_mm_client_check.bin"
self.s3_path = d / f"raw_s3_{stamp}_mm_client_check.bin"
self._bw = open(self.bw_path, "wb")
self._s3 = open(self.s3_path, "wb")
def close_capture(self) -> None:
for f in (self._bw, self._s3):
if f:
f.close()
def connect(self):
return self._inner.connect()
def disconnect(self):
return self._inner.disconnect()
def is_connected(self):
return self._inner.is_connected()
def write(self, data: bytes):
self.bytes_out += len(data)
if self._bw:
self._bw.write(data); self._bw.flush()
return self._inner.write(data)
def read(self, n: int) -> bytes:
chunk = self._inner.read(n)
if chunk:
self.reads += 1
self.bytes_in += len(chunk)
if self._s3:
self._s3.write(chunk); self._s3.flush()
return chunk
# ⚠ HYPOTHESIS, 6 events. content[11] of the 0x0C record separated 4 waveforms
# from 2 histograms cleanly and was constant within each group. A 4/2 split is
# thin evidence for a byte that could be anything, so _decode() below does NOT
# trust it -- it tries the other suffix on failure and says when the guess was
# wrong. The protocol reference states no type field is known; this may be it.
_TYPE_BYTE = 11
_TYPES = {0x07: ".IDFW", 0x08: ".IDFH"}
def _event_type(record: bytes) -> str:
if len(record) <= _TYPE_BYTE:
return "?"
b = record[_TYPE_BYTE]
return {0x07: "waveform", 0x08: "histogram"}.get(b, f"unknown(0x{b:02x})")
def _decode(blob: bytes, key: bytes, record: bytes) -> None:
"""Decode the downloaded bytes, proving they are a real event file.
read_idf_file() picks waveform vs histogram from the FILENAME SUFFIX, and a
wire download has no filename -- so the suffix has to come from somewhere.
This tries the 0x0C type byte first and the other suffix second; getting a
decode either way proves the chunk assembly, and which one worked is itself
the finding.
"""
import tempfile
from micromate.idf_file import read_idf_file
guess = _TYPES.get(record[_TYPE_BYTE] if len(record) > _TYPE_BYTE else -1, ".IDFW")
order = [guess] + [e for e in (".IDFW", ".IDFH") if e != guess]
for n, ext in enumerate(order):
with tempfile.NamedTemporaryFile(suffix=ext, delete=False) as f:
f.write(blob)
tmp = f.name
try:
res = read_idf_file(tmp)
samples = sum(len(v) for v in getattr(res, "samples", {}).values())
note = "" if n == 0 else f" *** the 0x0C type byte guessed {guess} — WRONG ***"
print(f" decoded OK as {ext}: {samples} samples{note}")
os.unlink(tmp)
return
except Exception as e:
last = f"{ext}: {type(e).__name__}: {e}"
finally:
if os.path.exists(tmp):
os.unlink(tmp)
print(f" decode failed BOTH ways — last: {last}")
out = Path(f"./{key.hex()}.bin")
out.write_bytes(blob)
print(f" saved to {out} for offline analysis")
def _select(refs, which: str):
"""Pick which events `--download` fetches."""
which = which.strip().lower()
if which == "first":
return refs[:1]
if which == "all":
return refs
if which == "largest":
return [max(refs, key=lambda r: r.size)]
return [r for r in refs if r.key_hex.lower() == which]
def _setup_lines(s) -> list[str]:
"""A decoded setup, laid out the way the unit's own menus group it."""
def sensors(geo: bool, mic: bool) -> str:
return " + ".join(n for n, on in (("geophones", geo), ("mic", mic)) if on) or "none"
stop = f"Auto, after {s.auto_stop_after_s} s quiet" if s.auto_record_stop else "Fixed"
if s.mic_type == "linear":
mic = f"linear, trigger {s.mic_trigger_db:.1f} dB ({s.mic_trigger_psi:.5f} psi)"
else:
mic = s.mic_type
sd = (f"on: {s.distance_ft:.1f} ft, {s.charge_weight_lb:.1f} lb"
+ (f" -> {s.scaled_distance:.2f}" if s.scaled_distance else "")
if s.scaled_distance_enabled else "off")
return [
f"record mode {s.record_mode_name}",
f"sample rate {s.sample_rate} sps",
f"histogram interval {s.histogram_interval_s} s",
f"record time {s.record_time_s:g} s stop: {stop}",
f"pre-trigger {s.pretrigger_s:g} s",
f"sensors on {sensors(s.geophones_active, s.mic_active)}",
f"trigger on {sensors(s.trigger_on_geophones, s.trigger_on_mic)}",
"geophone trigger " + " / ".join(f"{v:.3f}" for v in s.geo_trigger_ips) + " in/s",
f"microphone {mic}",
f"job number {s.job_number} ({'on' if s.job_number_enabled else 'off'})",
f"scaled distance {sd}",
*(f"note {k:<15}{v!r}" for k, v in s.notes.items()),
]
def step(label: str, fn, show=None):
"""Run one read, report how long it took and what it returned."""
t0 = time.monotonic()
try:
value = fn()
except Exception as e:
print(f" {label:.<26} FAILED {type(e).__name__}: {e}")
return None
ms = 1000 * (time.monotonic() - t0)
shown = value if isinstance(value, str) else repr(value)
if isinstance(value, list):
shown = f"{len(value)} entries"
if show:
shown = show(value)
print(f" {label:.<26} {ms:7.0f} ms {shown}")
return value
def main() -> int:
ap = argparse.ArgumentParser(
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
)
ap.add_argument("target", help="host:port for TCP, or a serial device path")
ap.add_argument("--baud", type=int, default=115200,
help="serial only; the USB-A/FTDI path runs at 115200. "
"Ignored by the USB-B 'PC' port, which is CDC-ACM "
"and negotiates its own rate.")
ap.add_argument("--timeout", type=float, default=10.0)
ap.add_argument("--download", action="store_true",
help="also walk the event chain and download (read-only)")
ap.add_argument("--event", default="first", metavar="WHICH",
help="which event --download fetches: a key in hex "
"(e.g. 055d4a83), 'first', 'largest', or 'all'. "
"'largest' is the one worth running on an unfamiliar "
"unit -- it is what exercises offsets past 64 KB.")
ap.add_argument("--capture", metavar="DIR",
help="also write a raw_bw_*/raw_s3_*.bin pair to DIR, so "
"this run can become a test fixture. Worth doing on "
"any unit whose firmware line is new to us.")
ap.add_argument("--lenient", action="store_true",
help="do not raise on a bad checksum — for diagnosis only")
a = ap.parse_args()
if ":" in a.target and not Path(a.target).exists():
host, _, port = a.target.rpartition(":")
inner = TcpTransport(host, int(port), connect_timeout=a.timeout)
path = f"TCP {host}:{port}"
else:
inner = StdlibSerial(a.target, baud=a.baud)
path = f"serial {a.target} @ {a.baud}"
transport = _Timed(inner, capture=a.capture)
mm = MicromateClient(transport, recv_timeout=a.timeout,
strict_checksums=not a.lenient)
print(f"\n{path} (read-only: POLL, SERIAL, state, status, setups)\n")
t0 = time.monotonic()
try:
mm.open()
except OSError as e:
print(f" connect.................... FAILED {e}")
return 2
print(f" {'connect':.<26} {1000*(time.monotonic()-t0):7.0f} ms")
try:
info = step("connect() identity", mm.connect)
if info is None:
print("\n Nothing answered. If the port opened but no frame came back,")
print(" check it is actually a Micromate and not another CDC-ACM device —")
print(" /dev/ttyACM* numbering shifts when anything else is plugged in.")
print(" `ls -l /dev/serial/by-id/` names each device and is stable.")
return 3
if info:
print(f" serial={info.serial} model={info.model} "
f"fw={info.firmware_line} monitoring={info.monitoring}")
print(f" active setup={info.active_setup!r}")
if info.firmware_line == "thor":
print(" (11.0BD / Thor line: 0x1C is 4 B longer -- read forward, "
"confirmed 2026-09-30)")
state = step("get_state()", mm.get_state)
if state:
print(f" {state}")
if state.battery_volts and not 2.5 < state.battery_volts < 9.0:
print(f" *** battery {state.battery_volts} V is impossible — "
f"this is the from-the-end offset bug. ***")
if state.device_time is None:
print(" *** device clock did not decode — dump raw below. ***")
print(f" raw 0x1C content: {_content(state.raw).hex(' ')}")
setup = step("get_setup()", mm.get_setup, show=lambda s: f"{s.name} (checksum ok)")
if setup:
print(" check each line against the unit's screen:")
for line in _setup_lines(setup):
print(f" {line}")
setups = step("list_setups()", mm.list_setups)
if setups:
print(f" first={setups[0]!r} last={setups[-1]!r}")
# ── SUB 0x06: event count, and (likely) the monitor-log count ─────
# content[0:4] is the event count: 3/3 against the chain walk, and THOR's
# own ReadEventRecordCount agrees. content[4:8] was once recorded as "a
# constant 9" -- it read 47 during the 10-14 ACH session against THOR's
# "Monitor Log count: 45", so it is very likely the monitor-log count.
# Still graded a strong candidate, not settled (reference, 10-14).
claimed = None
raw06 = step("0x06 storage range", mm.protocol.read_storage_range)
if raw06:
c = _content(raw06)
claimed = int.from_bytes(c[0:4], "big")
print(f" content[0:4] = {claimed} <- event count")
print(f" content[4:8] = {int.from_bytes(c[4:8],'big')} "
f"<- likely the monitor-log count (strong candidate)")
if a.download:
print("\n event chain (read-only), via MicromateClient:")
t1 = time.monotonic()
refs = mm.list_events() # walks to the sentinel
walk = time.monotonic() - t1
print(f" {len(refs)} events in {walk:.1f} s "
f"({walk/max(len(refs),1):.2f} s each, 3 round trips per event)")
if claimed is not None:
verdict = ("✓ AGREES" if claimed == len(refs)
else f"✗ DISAGREES (0x06 said {claimed})")
print(f" 0x06 count vs chain length: {verdict}")
for ref in refs:
print(f" {ref}")
print(f" would be filed as {ref.filename}")
if refs:
wanted = _select(refs, a.event)
if not wanted:
print(f"\n --event {a.event!r} matched nothing")
else:
print(f"\n download ({len(wanted)} of {len(refs)}, "
f"THOR's interleaved order):")
want_keys = {r.key_hex for r in wanted}
# iter_events() walks the chain; download only the selected
# events, at the cursor position THOR would be at.
for ref in mm.iter_events():
if ref.key_hex not in want_keys:
continue
# ⚠ Use the size actually requested. This printed
# `size // 1024` -- THOR's chunk size -- while the
# download used the 16 KB default, so it reported 71
# requests for a walk that made 5. A diagnostic that
# misreports what it did is worse than one that says
# nothing, and this one nearly had me reading a working
# 16 KB download as a broken 1 KB one.
n_chunks = -(-ref.size // CHUNK_SIZE)
note = (" <- past 64 KB, carries into params[1]"
if ref.size > 0x10000 else "")
t1 = time.monotonic()
try:
result = mm.get_event(ref) # verify=True
except Exception as e:
print(f" {ref.key_hex} {ref.size:7} B "
f"FAILED {type(e).__name__}: {e}")
continue
dt = max(time.monotonic() - t1, 1e-6)
n = sum(len(v) for v in getattr(result, "samples", {}).values())
err = mm.decode_error(ref, result)
check = ("PVS %+.4f%%" % (100 * err) if err is not None
else "PVS n/a (histogram)")
print(f" {ref.key_hex} {ref.record_type:9} "
f"{ref.size:7} B {n_chunks:3} req @ {CHUNK_SIZE} B "
f"{dt:5.1f} s {n:6} samples {check}{note}")
except ProtocolError as e:
print(f"\n ABORTED {type(e).__name__}: {e}")
return 3
finally:
mm.close()
transport.close_capture()
if a.capture:
print(f"\n capture written:\n {transport.bw_path}\n {transport.s3_path}")
print(" parse it with: python3 scratch/mm_frame_parse.py "
f"{transport.bw_path} {transport.s3_path}")
elapsed = time.monotonic() - t0
print(f"\n transport: {transport.reads} reads, "
f"{transport.bytes_in} B in, {transport.bytes_out} B out, "
f"{elapsed:.1f} s total")
print(" Measured 2026-09-29, UM12947, same unit both ways:")
print(" USB-B (CDC-ACM) 83 reads list_setups 0.46 s download 394 KiB/s")
print(" RX55 (TCP) 36 reads list_setups 16.05 s download 1.6 KiB/s")
print(" The modem needs FEWER reads, not more -- it buffers ~1 s and then")
print(" forwards one large segment, where CDC-ACM delivers many small ones.")
print(" Cellular cost, measured: ~0.21 s per request + ~2,350 B/s.")
print(" So STATUS work is round-trip bound (minimise commands) but a")
print(" DOWNLOAD is throughput bound -- 16 KB chunks save ~30% on a large")
print(" event, not 14x. An earlier note claiming cost was independent of")
print(" payload was fitted only to sub-1 KB responses.\n")
return 0
if __name__ == "__main__":
raise SystemExit(main())
-91
View File
@@ -1,91 +0,0 @@
#!/usr/bin/env python3
"""Dry run a Micromate write against a live unit: do the reads, print the plan.
Sends READS only. The write frames are built from the unit's own blocks and
printed for review -- step 1 of the bench protocol for every first live write
(parity spec, Testing). The protocol's opcode gate refuses every write SUB on
this connection, so nothing else can go out even by mistake.
sg dialout -c ".venv/bin/python bridges/mm_dry_run.py /dev/ttyACM0 call-home-off"
.venv/bin/python bridges/mm_dry_run.py --host 10.0.0.5 --tcp-port 9034 setup-rewrite
The JSON carries a `reads` block (length of each block read, and for
setup-rewrite the blocks themselves in hex) so the plan can be checked against
what the unit actually said.
⚠ `0x1A` reads the keypad's edit buffer live. A setup read taken while someone
is in the unit's menu includes their unsaved edits, and pushing that plan would
commit them.
⚠ The setup-rewrite JSON embeds the unit's whole `0x1A` block (job number,
notes), so do not paste it anywhere public.
"""
from __future__ import annotations
import argparse
import json
import sys
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from micromate.client import CONTENT, MicromateClient # noqa: E402
from micromate.writes import ( # noqa: E402
plan_call_home_enabled, plan_setup_push, plan_start_monitoring, plan_stop_monitoring,
)
from minimateplus.transport import SerialTransport, TcpTransport # noqa: E402
ACTIONS = ("start", "stop", "call-home-on", "call-home-off", "setup-rewrite")
def _content(data: bytes) -> bytes:
"""The protocol's read_* methods return the response data with its 11-byte prefix."""
return bytes(data)[CONTENT:]
def main() -> int:
ap = argparse.ArgumentParser(description=__doc__.splitlines()[0])
ap.add_argument("port", nargs="?", help="serial port, e.g. /dev/ttyACM0")
ap.add_argument("action", choices=ACTIONS)
ap.add_argument("--host")
ap.add_argument("--tcp-port", type=int, default=9034)
ap.add_argument("--baud", type=int, default=115200)
a = ap.parse_args()
if not (a.port or a.host):
ap.error("give a serial port or --host")
transport = TcpTransport(a.host, port=a.tcp_port) if a.host else SerialTransport(a.port, a.baud)
mm = MicromateClient(transport) # no execute(): nothing here can transmit a write
mm.open()
try:
info = mm.connect()
p = mm.protocol
reads = {}
if a.action == "start":
plan = plan_start_monitoring()
elif a.action == "stop":
plan = plan_stop_monitoring()
elif a.action.startswith("call-home"):
ch = _content(p.read_call_home_config())
reads["0x2C"] = {"len": len(ch)}
plan = plan_call_home_enabled(ch, a.action == "call-home-on")
else:
name = mm.get_active_setup()
prefs = _content(p.read_event_index())
trig = _content(p.read_trigger_config())
setup = _content(p.read_compliance_config())
reads = {"active_setup": name,
"0x08": {"len": len(prefs), "hex": prefs.hex()},
"0x2E": {"len": len(trig), "hex": trig.hex()},
"0x1A": {"len": len(setup), "hex": setup.hex()}}
plan = plan_setup_push(prefs, trig, setup, name)
out = plan.describe()
out["unit"] = {"serial": info.serial, "firmware_line": info.firmware_line}
out["reads"] = reads
print(json.dumps(out, indent=1))
finally:
mm.close()
return 0
if __name__ == "__main__":
sys.exit(main())
-338
View File
@@ -1,338 +0,0 @@
#!/usr/bin/env python3
"""
mm_link.py — a "perfect modem" between THOR and a Micromate, with a readable
log and deliberate fault injection.
Why
---
THOR gives almost no visibility into a connection: a refresh button, two poll
intervals, and no way to see whether a check succeeded, timed out, or was never
sent. When a unit "won't stay connected" there is nothing to look at.
This sits where the cellular modem would sit and answers the question directly:
* **What is THOR actually doing?** Every frame is decoded and timestamped —
`POLL`, `MONITOR_STATUS`, `SETUP_NAME_READ` — not a hex dump.
* **Is it even trying?** Silence is visible: the log shows gaps.
* **How does it behave when the link misbehaves?** Faults can be injected on
demand, which a real cell link will not do on cue.
Point THOR at this host and port exactly as if it were a modem (Communication:
TCP, IP: <this host>, Port: <--listen>).
Fault injection
---------------
Write a mode into the control file (default `mm_link.ctl`) and it takes effect
on the next byte:
echo pass > mm_link.ctl # normal relay
echo blackhole > mm_link.ctl # TCP stays up, bytes are swallowed
echo drop > mm_link.ctl # close the connection abruptly (RST-ish)
echo delay:2.0 > mm_link.ctl # forward, but 2 s late in both directions
echo onewaydev > mm_link.ctl # THOR->unit passes, unit->THOR is swallowed
**`blackhole` is the one that matters.** It reproduces the classic cellular
failure: the socket is still open as far as both ends are concerned, but nothing
crosses. A client that relies on TCP to tell it the peer is gone will sit there
until the OS keepalive fires — which by default is about two hours.
Usage
-----
python3 bridges/mm_link.py --serial /dev/ttyACM0 --baud 115200 \\
--listen 12345 --logdir ~/mm-captures
Writes, per session:
<logdir>/mmlink_<ts>/session.log decoded, timestamped, human-readable
<logdir>/mmlink_<ts>/raw_bw.bin THOR -> unit, raw
<logdir>/mmlink_<ts>/raw_s3.bin unit -> THOR, raw
The raw pair loads straight into `scratch/mm_frame_parse.py`.
"""
from __future__ import annotations
import argparse
import datetime
import os
import socket
import sys
import threading
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent / "scratch"))
try:
from mm_frame_parse import SUBNAME, destuff # noqa: F401
except Exception: # pragma: no cover
SUBNAME = {}
import errno
import select
import termios
DLE, STX, ETX, ACK = 0x10, 0x02, 0x03, 0x41
_BAUD = {9600: termios.B9600, 19200: termios.B19200, 38400: termios.B38400,
57600: termios.B57600, 115200: termios.B115200}
class SerialPort:
"""Minimal raw serial port on stdlib termios — no pyserial dependency.
The bench hosts are whatever is to hand; requiring a pip install on someone
else's machine is a poor trade for the ~30 lines this saves.
"""
def __init__(self, path: str, baud: int):
if baud not in _BAUD:
raise ValueError(f"unsupported baud {baud}; pick one of {sorted(_BAUD)}")
self.fd = os.open(path, os.O_RDWR | os.O_NOCTTY | os.O_NONBLOCK)
a = termios.tcgetattr(self.fd)
a[0] = 0 # iflag: no translation
a[1] = 0 # oflag: raw
a[2] = termios.CS8 | termios.CREAD | termios.CLOCAL # cflag: 8N1, ignore modem lines
a[3] = 0 # lflag: non-canonical, no echo
a[4] = a[5] = _BAUD[baud]
a[6] = list(a[6])
a[6][termios.VMIN] = 0
a[6][termios.VTIME] = 0
termios.tcsetattr(self.fd, termios.TCSANOW, a)
termios.tcflush(self.fd, termios.TCIOFLUSH)
def read(self, n: int) -> bytes:
r, _, _ = select.select([self.fd], [], [], 0.2)
if not r:
return b""
try:
return os.read(self.fd, n)
except OSError as e:
if e.errno in (errno.EAGAIN, errno.EWOULDBLOCK):
return b""
raise
def write(self, data: bytes) -> None:
while data:
try:
data = data[os.write(self.fd, data):]
except OSError as e:
if e.errno in (errno.EAGAIN, errno.EWOULDBLOCK):
select.select([], [self.fd], [], 0.2)
continue
raise
def close(self) -> None:
try:
os.close(self.fd)
except OSError:
pass
def name_of(sub: int, is_request: bool) -> str:
if is_request:
return SUBNAME.get(sub, f"SUB_{sub:02X}")
return "rsp " + SUBNAME.get(0xFF - sub, f"SUB_{0xFF - sub:02X}")
class FrameSniffer:
"""Accumulate bytes and report complete frames, without altering the stream."""
def __init__(self, is_request: bool):
self.is_request = is_request
self.buf = bytearray()
def feed(self, data: bytes):
"""Yield (sub, payload_len) for each complete frame seen."""
self.buf.extend(data)
while True:
start = -1
for i, b in enumerate(self.buf):
if self.is_request and b == ACK and i + 1 < len(self.buf) and self.buf[i + 1] == STX:
start = i
break
if not self.is_request and b == STX:
start = i
break
if start < 0:
if len(self.buf) > 8192:
del self.buf[:-16]
return
j = start + (2 if self.is_request else 1)
end = -1
while j < len(self.buf):
if self.buf[j] == DLE and j + 1 < len(self.buf):
j += 2
continue
if self.buf[j] == ETX:
end = j
break
j += 1
if end < 0:
return # wait for more bytes
body = self.buf[start:end + 1]
del self.buf[:end + 1]
# SUB sits at a fixed spot past the leading framing -- but it is
# DLE-escaped when its own value is 0x02/0x03/0x04/0x10, so a raw
# read reports 0x10 for those. SUB 0x02 was being logged as
# "SUB_10" until this was handled.
off = 5 if self.is_request else 3
if len(body) > off:
sub = body[off]
if sub == DLE and len(body) > off + 1:
sub = body[off + 1]
yield sub, len(body)
class Link:
def __init__(self, args):
self.args = args
self.mode = "pass"
self.delay = 0.0
self.ctl = Path(args.control)
self.session: Path | None = None
self.log_fh = None
self.raw = {}
self.t0 = time.time()
self.counts = {}
# ── logging ────────────────────────────────────────────────────────────
def open_session(self):
ts = datetime.datetime.now().strftime("%Y%m%d_%H%M%S")
self.session = Path(self.args.logdir) / f"mmlink_{ts}"
self.session.mkdir(parents=True, exist_ok=True)
self.log_fh = open(self.session / "session.log", "a", buffering=1)
self.raw = {
"bw": open(self.session / "raw_bw.bin", "ab"),
"s3": open(self.session / "raw_s3.bin", "ab"),
}
self.say(f"=== session {ts} — serial {self.args.serial} @ {self.args.baud} ===")
def say(self, text: str):
line = f"{datetime.datetime.now().strftime('%H:%M:%S.%f')[:-3]} {text}"
print(line, flush=True)
if self.log_fh:
self.log_fh.write(line + "\n")
# ── control file ───────────────────────────────────────────────────────
def poll_control(self):
while True:
try:
if self.ctl.exists():
want = self.ctl.read_text().strip().lower()
if want.startswith("delay:"):
d = float(want.split(":", 1)[1])
if ("delay", d) != (self.mode, self.delay):
self.mode, self.delay = "delay", d
self.say(f"*** MODE -> delay {d}s ***")
elif want and want != self.mode:
self.mode, self.delay = want, 0.0
self.say(f"*** MODE -> {want} ***")
except Exception:
pass
time.sleep(0.25)
# ── the relay ──────────────────────────────────────────────────────────
def pump(self, src, dst, tag: str, is_request: bool, stop: threading.Event):
sniff = FrameSniffer(is_request)
arrow = "THOR->unit" if is_request else "unit->THOR"
last = time.time()
while not stop.is_set():
timed_out = False
try:
data = src.recv(4096) if isinstance(src, socket.socket) else src.read(4096)
except TimeoutError:
timed_out = True
# socket.timeout subclasses OSError, so it MUST be caught first.
# Treating it as a dead socket closes the connection after 200 ms
# of quiet -- which is exactly what `blackhole` produces, so the
# relay killed the link it was supposed to be faking a fault on.
data = b""
except OSError:
break
if isinstance(src, socket.socket) and data == b"" and not timed_out:
self.say(f"{arrow}: peer closed the connection")
break
if not data:
if time.time() - last > self.args.quiet_after and self.counts:
self.say(f"--- {self.args.quiet_after:.0f}s with no traffic ---")
last = time.time()
continue
last = time.time()
self.raw[tag].write(data)
self.raw[tag].flush()
for sub, ln in sniff.feed(data):
label = name_of(sub, is_request)
self.counts[label] = self.counts.get(label, 0) + 1
self.say(f"{arrow} {label:<20} ({ln} B)"
+ ("" if self.mode == "pass" else f" [mode={self.mode}]"))
mode = self.mode
if mode == "drop":
self.say(f"{arrow}: DROPPING the connection (fault injection)")
stop.set()
break
if mode == "blackhole":
continue # swallow, keep the socket open
if mode == "onewaydev" and not is_request:
continue # unit's replies never reach THOR
if mode == "delay" and self.delay:
time.sleep(self.delay)
try:
if isinstance(dst, socket.socket):
dst.sendall(data)
else:
dst.write(data)
except OSError:
break
stop.set()
def serve(self):
srv = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
srv.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
srv.bind(("0.0.0.0", self.args.listen))
srv.listen(5)
self.open_session()
self.say(f"listening on 0.0.0.0:{self.args.listen} control file: {self.ctl}")
self.say("point THOR at this host/port as Communication=TCP")
threading.Thread(target=self.poll_control, daemon=True).start()
while True:
conn, addr = srv.accept()
conn.settimeout(0.2)
self.say(f"+++ THOR connected from {addr[0]}:{addr[1]} +++")
try:
ser = SerialPort(self.args.serial, self.args.baud)
except OSError as e:
self.say(f"!!! cannot open {self.args.serial}: {e}")
conn.close()
continue
stop = threading.Event()
ts = [
threading.Thread(target=self.pump, args=(conn, ser, "bw", True, stop), daemon=True),
threading.Thread(target=self.pump, args=(ser, conn, "s3", False, stop), daemon=True),
]
for t in ts:
t.start()
for t in ts:
t.join()
conn.close()
ser.close()
summary = ", ".join(f"{k}x{v}" for k, v in sorted(self.counts.items()))
self.say(f"--- connection closed. frames this session: {summary or 'none'} ---")
def main():
ap = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
ap.add_argument("--serial", default="/dev/ttyACM0")
ap.add_argument("--baud", type=int, default=115200)
ap.add_argument("--listen", type=int, default=12345)
ap.add_argument("--logdir", default=os.path.expanduser("~/mm-captures"))
ap.add_argument("--control", default="mm_link.ctl")
ap.add_argument("--quiet-after", type=float, default=30.0,
help="log a marker after this many seconds of silence")
Link(ap.parse_args()).serve()
if __name__ == "__main__":
main()
-239
View File
@@ -1,239 +0,0 @@
#!/usr/bin/env python3
"""
mm_probe.py — answer "why can't we reach this unit?" in one command.
THOR reports a failed connection as "disconnected" and nothing else. That single
word covers at least four completely different faults with four different fixes,
and telling them apart is the difference between a modem reboot and a site visit:
* **connection refused** something answered and said no — wrong port, or the
modem is refusing a further session
* **connect timed out** nothing answered at all — trusted-IP whitelist,
firewall, or the modem is off the network
* **connected, no reply** the MODEM answered but the unit did not. The TCP
path is fine; the modem is not forwarding to serial.
This is the signature of a wedged transparent-TCP
session, and it is the one THOR cannot distinguish
from any of the others
* **replied** the unit is alive; the problem is upstream software
Read-only. It sends `POLL`, then optionally `SERIAL` and the state read — the
same three commands THOR's own connection check uses — and never writes.
Usage
-----
python3 bridges/mm_probe.py 63.45.161.30:9034
python3 bridges/mm_probe.py 10.0.0.8:12345 --timeout 5
python3 bridges/mm_probe.py <host:port> --slots 3
`--slots N` opens N connections at once and reports how many the far end accepts.
A transparent-TCP modem typically serves **one** session; if the first succeeds
and the rest are refused or hang, that confirms the single-slot behaviour and
explains why a leaked session takes a unit offline until the slot frees.
Works for both series: a Series III reply opens `DLE STX`, a Micromate reply
opens with a bare `STX`, so the probe also tells you which one answered.
"""
from __future__ import annotations
import argparse
import socket
import sys
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from minimateplus.framing import build_bw_frame # noqa: E402
DLE, STX, ETX = 0x10, 0x02, 0x03
def destuff(raw: bytes) -> bytes:
"""Strip framing and DLE escapes; return the payload without its checksum."""
i = 1 if raw and raw[0] == STX else (2 if len(raw) > 1 and raw[1] == STX else 0)
out = bytearray()
while i < len(raw):
b = raw[i]
if b == DLE and i + 1 < len(raw):
out.append(raw[i + 1])
i += 2
continue
if b == ETX:
break
out.append(b)
i += 1
return bytes(out[:-1]) if len(out) > 1 else b""
# Reads are two-step on Series III: a probe at offset 0, then a data read at the
# block's length. THOR sends these offsets, and they also work on a Micromate.
OFFSETS = {0x5B: 0x0030, 0x15: 0x000A, 0x49: 0xFFFF}
def exchange(sock: socket.socket, sub: int, timeout: float) -> tuple[bytes, float]:
sock.sendall(build_bw_frame(sub, OFFSETS.get(sub, 0)))
t0 = time.time()
buf, deadline = b"", t0 + timeout
sock.settimeout(0.3)
while time.time() < deadline:
try:
chunk = sock.recv(4096)
if not chunk:
break
buf += chunk
if buf.endswith(bytes([ETX])) and len(buf) > 8:
break
except TimeoutError:
continue
except OSError:
break
return buf, time.time() - t0
def step(n: int, label: str, result: str) -> None:
print(f" [{n}] {label:.<28} {result}")
def probe(host: str, port: int, timeout: float) -> int:
print(f"\ntarget {host}:{port} (read-only: POLL, SERIAL, state)\n")
# ── 1. TCP ────────────────────────────────────────────────────────────
t0 = time.time()
try:
sock = socket.create_connection((host, port), timeout=timeout)
except ConnectionRefusedError:
step(1, "TCP connect", f"REFUSED after {1000*(time.time()-t0):.0f} ms")
print("\nverdict: something answered and actively refused.")
print(" Not a silent firewall drop — the host is reachable.")
print(" Wrong port, the service is down, or the modem is refusing")
print(" an additional session because its one slot is in use.")
return 2
except (TimeoutError, socket.timeout):
step(1, "TCP connect", f"TIMED OUT after {time.time()-t0:.1f} s")
print("\nverdict: nothing answered at all.")
print(" A silent drop, which is what a trusted-IP whitelist looks")
print(" like — it discards rather than refuses. Check the modem's")
print(" Trusted IPs (and note a VPN changes the IP you arrive from),")
print(" the firewall, and whether the modem is on the network.")
return 3
except OSError as e:
step(1, "TCP connect", f"FAILED: {e}")
return 4
step(1, "TCP connect", f"ok ({1000*(time.time()-t0):.0f} ms)")
# ── 2. POLL ───────────────────────────────────────────────────────────
try:
raw, dt = exchange(sock, 0x5B, timeout)
except OSError as e:
step(2, "POLL", f"send failed: {e}")
sock.close()
return 4
if not raw:
step(2, "POLL", f"NO REPLY in {timeout:.1f} s")
print("\nverdict: the MODEM answered but the unit did not.")
print(" TCP is fine end to end — something accepted the connection.")
print(" What is missing is the serial side. Two quite different")
print(" causes produce this, and they are NOT distinguishable from")
print(" here:")
print("\n 1. SOMEONE ELSE HOLDS THE SESSION. These modems bridge ONE")
print(" TCP session to serial at a time. A second connection is")
print(" accepted and then simply not forwarded. Confirmed 2026-09-26:")
print(" with THOR connected this probe saw exactly this; the moment")
print(" THOR disconnected the same probe returned the serial number.")
print(" ** Check whether THOR (or anything else) has the unit first. **")
print("\n 2. The serial path is genuinely broken — a stale session the")
print(" modem never released, a cable the unit cannot enumerate, or")
print(" a unit that is off.")
print("\n Try, in order:")
print(" 1. Disconnect any other client and re-probe. If it answers,")
print(" it was contention, not a fault.")
print(" 2. The cable's chipset. A Micromate drives FTDI and CDC-ACM")
print(" only — a Prolific PL2303 gives it no serial port at all.")
print(" lsusb: FTDI is 0403, Prolific 067b.")
print(" 3. Power-cycle the UNIT with the cable attached (hold power")
print(" 5 s, through the two-stage prompt). Its USB host rescans")
print(" on cold boot; it may not on hot-swap.")
print(" 4. AirLink OS -> TCP Idle Timeout. If 0/disabled, a stale")
print(" session holds the slot indefinitely. 2 minutes is the")
print(" value this project standardised on.")
sock.close()
return 5
series = "Series III (DLE STX)" if raw[0] == DLE else "Micromate (bare STX)"
step(2, "POLL", f"reply {len(raw)} B in {1000*dt:.0f} ms")
p = destuff(raw)
ok = len(p) > 3 and p[2] == 0xFF - 0x5B
step(3, "frame", f"{'valid' if ok else 'MALFORMED'}, {series}")
if not ok:
print("\nverdict: something replied, but not a seismograph.")
print(" Another service is on this port, or the modem is in a mode")
print(" that injects its own text (check Quiet Mode / AT echo).")
print(f" first bytes: {raw[:16].hex(' ')}")
sock.close()
return 6
# ── 3. identity + state ───────────────────────────────────────────────
for n, (sub, label) in enumerate(((0x15, "serial"), (0x49, "state")), start=4):
try:
r, dt = exchange(sock, sub, timeout)
d = destuff(r)[5:]
if sub == 0x15:
# serial is a null-terminated run; a further field follows it
serial = bytes(d[11:]).split(b"\x00")[0]
step(n, label, serial.decode("ascii", "replace") or "(empty)")
else:
step(n, label, "MONITORING" if len(d) > 11 and d[11] else "idle")
except OSError:
step(n, label, "no reply")
sock.close()
print("\nverdict: the unit is alive and answering.")
print(" If THOR still shows it disconnected, the fault is in THOR, not")
print(" the network or the device.")
return 0
def slots(host: str, port: int, n: int, timeout: float) -> None:
print(f"\nopening {n} simultaneous connections to {host}:{port}\n")
held = []
for i in range(n):
try:
s = socket.create_connection((host, port), timeout=timeout)
held.append(s)
step(i + 1, f"connection {i+1}", "accepted")
except ConnectionRefusedError:
step(i + 1, f"connection {i+1}", "REFUSED")
except (TimeoutError, socket.timeout):
step(i + 1, f"connection {i+1}", "timed out")
except OSError as e:
step(i + 1, f"connection {i+1}", f"failed: {e}")
print(f"\n{len(held)} of {n} accepted.")
if len(held) == 1:
print(" Single-slot behaviour confirmed — this far end serves ONE")
print(" session at a time. A connection that is never closed takes")
print(" the unit offline until the idle timeout frees the slot.")
for s in held:
s.close()
def main() -> int:
ap = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
ap.add_argument("target", help="host:port, e.g. 63.45.161.30:9034")
ap.add_argument("--timeout", type=float, default=10.0)
ap.add_argument("--slots", type=int, metavar="N",
help="open N simultaneous connections to test single-slot behaviour")
a = ap.parse_args()
host, _, port = a.target.rpartition(":")
if not host:
ap.error("target must be host:port")
if a.slots:
slots(host, int(port), a.slots, a.timeout)
return 0
return probe(host, int(port), a.timeout)
if __name__ == "__main__":
raise SystemExit(main())
-212
View File
@@ -1,212 +0,0 @@
> ## SUPERSEDED 2026-08-25 — the block is uniformly BIG-ENDIAN
>
> The `uint8` peak / `annotation` byte model described below is wrong,
> though it decoded quiet data correctly. The real layout:
>
> - **Every per-channel field is `uint16` big-endian.** `T_peak` is
> `[5:7]`, `T_halfperiod` `[7:9]`, `V_peak` `[9:11]`, and so on.
> Only `block_ctr` at `[2:4]` is little-endian.
> - The **marker is `block[4]` alone**, not a `uint16 LE` at `[4:6]`.
> Testing `[4:6] == 10` forced `block[5] == 0`, which is exactly what
> capped every geo peak at one byte (255 counts = 1.275 in/s).
> - The **"annotation" byte was never an annotation** — it is the high
> byte of the big-endian half-period. That is why it was non-zero
> precisely on the sub-Hz intervals Blastware renders as `<1.0`.
> - The **final block of the stream carries tail `9c 06 00 42`** instead
> of `1e 0a 00 00`, and arbitrary bytes at `[21:23]`. Rejecting it
> dropped the last interval of nearly every histogram — often the one
> holding the event peak, so the file's PPV read low.
>
> Verified against 1211 production histograms paired with their Blastware
> ASCII exports: **1211/1211 decode exactly** (interval count plus every
> per-interval peak), and 842,442 per-interval frequency comparisons match
> with zero mismatches. The uint8 model scored 1204/1211 — the seven
> failures are exactly the files containing a peak above 1.275 in/s.
>
> The section below is retained as the reasoning trail.
# Histogram body codec — FULLY DECODED (2026-05-20)
Clean working status doc for the MiniMate Plus histogram-mode event
body codec. Companion to `waveform_codec_re_status.md`. The deep
historical record (with retractions and dated analyses) lives in
`docs/instantel_protocol_reference.md §7.6.2`; the authoritative
implementation lives in `minimateplus/histogram_codec.py`.
## TL;DR
**The codec is fully decoded.** Every field of every block in the
in-repo histogram fixture corpus decodes byte-exact against BW's
ASCII export.
26 regression tests pass against ~3,500 blocks across 5 in-repo
fixtures, plus a synthetic regression block taken from a real
BE9558 prod event to lock in the uint8-peak interpretation.
**Important correction (2026-05-21):** the per-channel peak count
is `uint8` at byte[6]/[10]/[14]/[18], NOT `uint16 LE` at byte[6:8]
etc. The N844 fixture corpus the original RE was done against has
zero values in bytes [7]/[11]/[15]/[19] for every block, so the
two interpretations happened to be equivalent. Cross-correlating
non-N844 events (BE9558 Tran-drift, BE18003 Histogram+Continuous)
against BW's per-interval ASCII export — 4 channels × ~1400 blocks
per event × multiple events = 100% byte-exact only when the peak
is read as uint8. Reading as uint16 LE produced peaks up to 268
in/s per channel and 35× inflated PVS sums when first deployed to
prod (rolled back, root-caused, and fixed in commit 7183b95+1).
## Body format
```
body = [stream of 32-byte data blocks] + [small trailing remnant]
```
Each block represents one histogram interval. Block layout:
```
[0] 0x00 always-zero tag
[1] segment_id (uint8) 0x00..0x03 — 256 blocks per segment
[2:4] block_ctr (uint16 LE) resets each segment (0x0100, 0x0101, …)
[4:6] 0x000a (uint16 LE) constant marker (= 10)
[6] T_peak_count uint8 Tran peak (count × 0.005 → in/s at Normal,
max 1.275 in/s — fits in uint8)
[7] T_annotation uint8 empirically non-zero on intervals with sub-Hz
or unmeasurable freq; meaning not fully RE'd
[8:10] T_halfperiod uint16 LE Tran half-period in samples
(freq_Hz = 512 / halfp; ≤ 5 means ">100 Hz")
[10] V_peak_count uint8 Vert peak
[11] V_annotation uint8
[12:14] V_halfperiod uint16 LE Vert freq half-period
[14] L_peak_count uint8 Long peak
[15] L_annotation uint8
[16:18] L_halfperiod uint16 LE Long freq half-period
[18] M_peak_count uint8 MicL peak count
(dB via waveform_codec.mic_count_to_db)
[19] M_annotation uint8
[20:22] M_halfperiod uint16 LE MicL freq half-period
[22:24] 0x00 0x00 constant
[24:28] 4-byte variable purpose unknown — possibly CRC,
timestamp delta, or psi(L) numeric;
not needed for waveform reconstruction
[28:32] 0x1e 0x0a 0x00 0x00 constant block-end signature
```
Reliable block-identification anchor:
```python
block[22:24] == b"\x00\x00" and block[28:32] == b"\x1e\x0a\x00\x00"
```
(The `1e 0a 00 00` constant tail is the most distinctive signature.)
## Per-channel encoding
| Channel | Peak encoding | Frequency encoding |
|---|---|---|
| Tran | count × 0.005 = in/s at Normal range | `freq_Hz = 512 / halfperiod` |
| Vert | same | same |
| Long | same | same |
| MicL | count → dB via `mic_count_to_db(count)` (same formula as waveform codec) | same |
**`>100 Hz` sentinel**: when halfperiod ≤ 5 (giving ≥100 Hz from the
512/halfp formula), BW displays `>100 Hz`. Codec's `half_period_to_hz`
returns `None` in this range.
## Verified facts (cross-checked against fixture corpus)
Example: N844L6Z8.ZR0H block 130 → all 8 decoded fields byte-exact:
```
binary samples [10, 6, 24, 4, 18, 5, 21, 5, 9]
TXT row [0.030, 21, 0.020, 28, 0.025, 24, 0.040, 0.000, 95.92, 57]
slot[0] = 10 marker
slot[1] = 6 × 0.005 = 0.030 in/s ✓ T_peak
slot[2] = 24 → 512/24 = 21.3 → 21 Hz ✓ T_freq
slot[3] = 4 × 0.005 = 0.020 in/s ✓ V_peak
slot[4] = 18 → 512/18 = 28.4 → 28 Hz ✓ V_freq
slot[5] = 5 × 0.005 = 0.025 in/s ✓ L_peak
slot[6] = 21 → 512/21 = 24.4 → 24 Hz ✓ L_freq
slot[7] = 5 → 81.94 + 20·log10(5) = 95.92 dB ✓ M_peak
slot[8] = 9 → 512/9 = 56.9 → 57 Hz ✓ M_freq
```
## Verified test coverage
`tests/test_histogram_codec.py` (24 tests):
- Block walking: yields one record per `.TXT` interval ± 1 (off-by-one
at the tail when recording was stopped mid-write). Segment-ID
groups of 256 blocks confirmed.
- Geo peaks: every block of N844L20G, N844L6Z8, N844L6XE, N844L23B
matches `.TXT` within the 0.0005 in/s quantization step.
- Geo freqs: every block of N844L6Z8 and N844L6XE matches `.TXT`
within 1 Hz (BW display rounds). `>100 Hz` sentinel handled correctly.
- Mic dB: every block of N844L6XE, N844L23B, N844L6Z8 matches `.TXT`
within 0.1 dB (BW display precision).
- Mic freq: matches `.TXT` within 1 Hz across active blocks.
## What's NOT yet decoded
- **Annotation bytes (`block[7]/[11]/[15]/[19]`)**. Empirically
non-zero on intervals where the per-channel ZC frequency comes
out as `N/A` or sub-Hz (`<1.0`, `1.X`). Hypothesis tested in the
RE session: byte != 0 ↔ sub-Hz freq. Only ~50% correlation
across the K558 corpus, so the relationship is more complex.
Possibilities: time-of-peak-within-interval, halfp extension for
very-long-period signals, or a debug/diagnostic field the firmware
writes opportunistically. Doesn't affect peak amplitudes or
waveform reconstruction. Captured as `record["annotations"]` for
future RE.
- **4-byte variable metadata field (bytes 24:28)**. Not needed for
waveform reconstruction. Speculation: per-block CRC, sub-second
timestamp offset, or a Mic psi(L) count not in the 9 samples.
Punt until something needs it.
- **Geo PVS (TXT col 7, e.g. "0.040 in/s")**. Not stored in the
block; can be approximated as `sqrt(T_peak² + V_peak² + L_peak²)`
but BW's value sometimes differs slightly (probably computed from
waveform-instant samples, not from per-channel peaks). Punt — the
`.h5` consumers don't need PVS as a sample channel.
- **Mic psi(L) value (TXT col 8)**. TXT shows it as a small psi value
derived from the dB measurement. Not in the 9 samples. Could be
derived from `M_peak_count` via the inverse of the dB formula plus
a psi calibration constant. Defer.
## Output shape
`decode_histogram_body` returns the standard 4-channel dict that
mirrors `waveform_codec.decode_waveform_v2`'s output:
```python
{
"Tran": [peak_count_per_interval, ...], # 16-count units (LSB = 0.005 in/s)
"Vert": [..., ...],
"Long": [..., ...],
"MicL": [..., ...], # raw ADC counts
}
```
Run through `waveform_codec.decoded_to_adc_counts` to get 1-count ADC
units (geo ×16, mic passthrough) for the standard `.h5` writer.
For the full per-interval record with frequencies + metadata, use
`decode_histogram_body_full()`.
## Where it's wired
- `minimateplus/event_file_io.py:read_blastware_file()` — first tries
the waveform codec, falls back to the histogram codec when the
waveform preamble isn't present. Same output shape, same
downstream pipeline.
- `scripts/backfill_sidecars.py` — the `has_samples` short-circuit
added during the histogram-codec-pending era still serves as a
defensive guard against truly undecodable files, but no longer
fires for valid histograms.
## Companion reference
- `docs/waveform_codec_re_status.md` — sibling status doc for the
much-more-complex waveform-mode codec.
- `docs/instantel_protocol_reference.md §7.6.2` — historical
protocol-reference entry. Structural framing matches what we
found; per-sample semantics were less documented than the `✅
CONFIRMED` badge suggested. This doc supersedes §7.6.2 where they
conflict on confidence level.
-563
View File
@@ -1,563 +0,0 @@
# IDF Protocol Reference — Thor / Micromate Series IV
Starting-point reference for reverse-engineering Instantel's Micromate
Series IV event-file format. Sibling to
[instantel_protocol_reference.md](instantel_protocol_reference.md) (the
Series III "Rosetta Stone") — this doc holds what we know so far and
the open questions still to crack.
> ⚠ **The "Status (2026-05-28)" block below is SUPERSEDED.** Its geo LSB
> (0.0003), its IDFH scale (`/32768 × 10`), its fixed body offset (`0x0f1f`)
> and its "87–99% byte-exact / loud events truncate" caveat were all wrong or
> incomplete. See **[Verified against Thor's own exports
> (2026-09-10)](#verified-against-thors-own-exports-2026-09-10)** — the
> decoder is now per-sample exact on 1,057,536/1,057,536 samples. The block
> is kept only for the reverse-engineering trail.
**Status (2026-05-28, SUPERSEDED):** ASCII text sidecar fully decoded (1,014
sample files round-trip). **Thor IDFW** binary now decodes via
`micromate.idf_file.read_idf_file()` — reuses the BW segment-rotated
block codec verbatim at fixed body offset `0x0f1f`; metadata (serial,
timestamp, sample_rate, record_time, calibration_date) extracted from
the binary header. Sample fidelity is 87–99% byte-exact on quiet
events; loud events hit the BW codec's known walker-stops-early
limitation. Residual ~3% drift on per-sample deltas (likely a
Thor-specific 12-bit delta refinement not yet modelled).
**Thor IDFH histograms also decoded.** Body has one or more segments;
each 12-byte segment header `[length_be 2B][0a 00 00 00][00 NN][05 3f]`
introduces `N = (length - 10) // 72` interval records of 72 bytes
each. Each interval = 4 × 16-byte per-channel records:
`[int16 min][int16 max][int16 ??][uint16 halfp][2B 00][uint16 ??][2B 00][uint16 ??]`.
Geo peak `= max(|min|, |max|) / 32768 × 10` in/s (matches sidecar
~1.8%); freq `= 512 / halfp` Hz (None for halfp ≤ 5 → ">100"
sentinel). Corpus: **all 859 Thor IDFH files decode, 181,071
intervals**. Wired through `read_idf_file()` →
`save_imported_idf()` → sidecar's `extensions.idf_intervals`.
**Note on the BE9439 outliers in the example corpus:** Two files
(`BE9439_20200713131747.IDFW` and `BE9439_20200713124251.IDFH`) are
**Series III Blastware** binaries, not Thor. Provenance: TMI tried
to use Thor to manage auto-call-homes for Series III units; the
experiment didn't work out, but it did leave a few BW event files
in Thor's per-serial directory structure with `.IDFW`/`.IDFH`
extensions — Thor's forwarder applied its own naming convention to
the BW bodies it was relaying. Their header `10 00 01 80 00 00
Instantel STRT ff fe <end_key> <start_key>` is the BW SUB 5A STRT
record, not a Thor body preamble. The reader detects them by
signature and raises `NotImplementedError` pointing callers at
`read_blastware_file()`, which extracts BW-format peaks from them.
**Still NYI for Thor IDFH:** per-channel `int16 field4` (possibly
time-of-peak); the two uint16 fields (probably PVS contributions);
8-byte interval tail (PVS data); mic dB(L) exact conversion constant.
## Verified against Thor's own exports (2026-09-10)
**The series-4 decoder is now per-sample exact.** 1,057,536 / 1,057,536
geophone samples across all 153 genuine Thor waveform files reproduce Thor's
own CSV export exactly; histogram peaks land within 2% on 858/858 files
(median error −0.004%).
### Ground truth — it was there all along
Thor writes `TXT/`, `CSV/`, `XML/` and `PDF/` exports beside every binary:
```
<serial dir>/UM13981_20220207084555.IDFW
<serial dir>/CSV/UM13981_20220207084555.IDFW.csv
```
The **CSV carries a per-sample block** — four columns (Tran, Vert, Long, Mic)
in in/s and psi, after the 2-column report header. That is the series-4
equivalent of Blastware's `_ASCII.TXT` exports, and it gives 1,012 paired
files (152 IDFW + 860 IDFH). Earlier notes in this file and in
`micromate/idf_file.py` asserted "Thor has no ASCII ground truth in the
corpus"; that was wrong, and it is why the decoder sat pinned to a
superseded walker with a scaling constant nobody could check.
Harness: `scratch/verify_thor_against_csv.py`.
### Geo LSB = 0.000310308 in/s per count (NOT 0.0003)
The old 0.0003 was read off the smallest non-zero sample in the exports —
but that is Thor's **4-decimal display rounding of the LSB, not the LSB**.
It read every series-4 geophone sample **3.3% low**. The quantisation
ladder gives it away: counts 1..6 export as 0.0003, 0.0006, 0.0009, 0.0012,
0.0016, 0.0019 — an LSB of exactly 0.0003 would end 0.0015, 0.0018.
Each exported sample constrains the LSB to the window that rounds to its
printed value. Intersecting 991,415 such constraints gives
```
LSB ∈ [0.000310307933, 0.000310308057] width 1.2e-10
```
so `_GEO_LSB_IPS = 0.000310308`, i.e. full scale 10.0 in/s = **32226.05
counts**. Corroboration: an IDFH interval that never recorded keeps its
min/max accumulator at its ±full-scale seed, and that seed is
`(min=+32226, max=-32226)`. ⚠ The tempting closed form `10.0/32226` is
very slightly wrong — it lands 4.5e-10 above the feasible window and loses
78 boundary samples while never winning one. **Series III uses 32000 counts
for the same 10.0 in/s, so the two generations do not share a scale.**
Independently confirmed on 8 production units (UM6047, UM11402, UM11719,
UM12947, UM13981, UM14133, UM20146, UM20147): every unit's median PPV error
against its device-reported peak moved from −3.3% to within ±0.03%. It is a
global constant, not a per-unit calibration.
### IDFH segment header: the counter is a uint16, and it is cumulative
```
[length_be 2B][0a 00 00 00][counter_be 2B][05 3f]
```
`counter` is the **0-based cumulative index of the last interval in the
segment** — 9, 19, 29, ... for the usual 10-intervals-per-segment layout
(`length` = 730).
The validator used to require `counter`'s high byte to be `0x00`. That
silently **capped every histogram at 250 intervals**: once the cumulative
counter passed 255 the high byte went non-zero and every later segment was
rejected. Any run longer than ~4 hours lost its tail — frequently the part
holding the event peak, so the file's PPV read low. **540 of 858 corpus
files were affected**; fixing it moved histogram peaks from 48.3% to 93.8%
within 0.5% of Thor's reported PPV.
### Unwritten interval slots carry a ±full-scale seed
An interval the device reserved but never wrote keeps `min = +32226`,
`max = -32226` on all four channels — `min > max`, impossible for real data.
Decoded naively it yields a 10.0 in/s peak on every channel and, being a
max-over-intervals, poisons the whole file's PPV. Rare but real: exactly 1
of 497,611 corpus intervals, and it inflated that file's Long PPV from
0.0081 to 10.0 in/s. The inversion is all-or-nothing across channels (0
partial cases), so requiring every channel to be inverted is a safe test.
### Record mode `00 00` — raw int16 absolute (MODE_RAW16)
The record chain's mode field at `off+8` takes a fourth value:
| mode | meaning | header |
|---|---|---|
| `02 00` | deltas + two int16 anchors | 14 B |
| `01 00` | absolute, tagged blocks | 10 B |
| `00 03` | raw 12-bit absolute, untagged | 10 B |
| **`00 00`** | **raw int16 BE absolute, untagged** | **10 B** |
A `MODE_RAW16` record with `length = 1032` carries exactly
`(1032 - 8) / 2 = 512` samples and reproduced Thor's export **512/512
exactly** on first test. Thor uses it for segment 0 (the pre-trigger
window) on some events. Before this mode existed the record fell through
the dispatch unhandled, so the channel silently lost its first 512 samples —
which is what produced the "loud events truncate" symptom.
`MODE_ABSOLUTE` is also valid as a **preamble** (the implicit segment-0 Tran
record); its tagged blocks start at `body[3]`, not `body[7]`, because its
header is 10 bytes rather than 14.
### Body offset is not fixed at 0x0f1f — and 0x0f1f is really a record + 7
A "body offset" is `<record start> + 7`, so that `body[0]` is the segment
index and `body[1:3]` is the mode. The canonical `0x0f1f` is simply the
record at `0x0f18`.
Searching for the literal preamble `00 02 00` finds only MODE_DELTA bodies,
and worse, it **matches the `[seg][mode]` bytes inside any record header**,
so the scan could pick a candidate part-way down the chain. That decodes a
plausible-looking but rotation-shifted body which drops each channel's
segment 0 — the real cause of the remaining truncations.
`_find_waveform_body_offset()` now anchors on record headers (the
`<channel_id> 00 00` signature at `+4`, validated with `is_record()`),
takes the **chain head** — a record no other record's length field points at
— and trial-decodes `head + 7`, preferring the candidate where all four
channels come out the same length.
⚠ Do **not** scan for candidate preambles instead: `MODE_RAW16` is
`00 00`, so every run of three zero bytes looks like a body start and each
costs a full trial decode (~0.5 s/file measured, vs 6 ms/file now).
### `40 NN` is not capped at NN=8 (2026-09-11)
`data_block_len()` rejected any `40 NN` int16 block with `NN > 0x08`. The cap
had no evidence behind it — every corpus available when it was written used
only NN ∈ {1, 2, 3, 4, 8}, so it was never exercised. Loud events use much
wider blocks:
| corpus | `40 NN` values | walker stops |
|---|---|---|
| first + 3-channel corpora | 1, 2, 3, 4, 8 | none |
| UM12947 2025-07..09 | 2, 4, 8, **12, 16, 20 … 196** | every value > 8 |
Because `walk_body`/`run` stop at the first unrecognised tag rather than
raising, this surfaced as **silently short channels** — e.g. Tran 1812 /
Vert 2132 / Long 2324 on a file whose export has 2324 for all three. The
real bound is the buffer (and the caller's record end), not a magic constant.
Verified against Thor's exports for UM12947 (2025-07-14 … 2025-09-25, 167
waveforms): length mismatches **22 → 0**, and **1,476,242 / 1,476,249**
samples exact.
⚠ These events are **not** truncated recordings, which was the competing
hypothesis — the exports carry the full sample count.
**The 7 residual samples are Thor's rounding, not ours.** Each differs by
exactly one 4th-decimal tick (e.g. decoded 3.3551 vs export 3.3550).
Intersecting the per-sample rounding constraints over this corpus is
**infeasible** — the binding pair (count 2013 → 0.6247, count 4351 → 1.3501)
contradict by 2.3e-11, i.e. 7e-5 relative. No single linear LSB can
reproduce every printed value, so Thor is not doing plain round-half-up on
`count × LSB`. Do not retune `_GEO_LSB_IPS` to chase these; it is already
pinned to ~1e-11.
### Mic-disabled units are a distinct shape (2026-09-10, second corpus)
Some units run with the microphone disabled — **3 channels, not 4** — and that
changes two structural things. Confirmed on the `9-10-26-csv-req` corpus
(UM11402, UM12947, UM20147): 139/139 waveforms and 877/877 histograms.
**Waveform: the body starts earlier.** A 3-channel unit has a shorter fixed
header and puts its record chain head at **`0x0dba`**, below the old
`_BODY_SCAN_FLOOR` of `0x0E00`. The head was therefore invisible to the scan,
which fell through to the *Vert* segment-0 record and decoded a body shifted
one position around the channel rotation. The signature is unmistakable:
```
Tran 3072 / Vert 2560 / Long 3072 / MicL 0 <- Vert exactly 512 short
```
46 of 139 files in that corpus were affected; all 46 became per-sample exact
once the floor dropped to `0x0C00`. Note the body-offset scoring also had to
stop requiring four channels — `len(lengths) >= 3`, not `== 4`, or `equal` is
permanently False for these events and the pick falls back to raw sample count.
**Histogram: the interval record is 56 bytes, not 72.**
```
interval_size = 16 × n_channels + 8 (72 for 4 channels, 56 for 3)
```
It is **not a constant**, and it cannot be inferred from `length` alone.
Derive the interval count from the segment counter — it is cumulative, so
`n = counter - previous_counter` — and then `stride = (length - 10) / n`.
`n_channels` follows from `(stride - 8) / 16`.
Assuming 72 read 7 intervals out of each 10-interval segment and then walked
off alignment into garbage that decoded as ~10 in/s peaks — inflating those
files' PPV by up to 191,000%. Fixing it moved the second corpus from 56.6% to
**100.0%** of histograms within 2% of Thor's reported PPV, and recovered 4
files that previously decoded no intervals at all.
### What is still open
- ~~23 of 575 production IDFW files~~ — **RESOLVED 2026-09-11.** Production
IDFW is now **575/575** with zero truncations and zero decode failures
(median PPV error −0.0007%). See "`40 NN` is not capped at NN=8" above.
- Mic → psi scale is still the rough `2.14e-6` regression, not derived.
- Per-channel `int16 field4` in the IDFH interval record (possibly
time-of-peak) and the 8-byte tail (PVS data) remain undecoded.
⚠ **Thor's histogram PPV has a display floor of 0.0050 in/s.** In the
production store 6,080 sidecar PPV values are exactly 0.0050 (next most
common value: 275 occurrences), and **41.4% of IDFH sidecars report a
component PPV larger than their own vector sum** — geometrically impossible.
On those quiet files the decoder's ~0.0025 in/s is *more* accurate than the
reference; do not "fix" the decoder to match it.
### Codec breakthroughs (2026-05-28)
- **Body offset is a fixed `0x0f1f`** across 151/154 corpus IDFW
files. Preceded by a 4-byte record-type marker (`46 00 00 00`)
+ magic preamble `00 02 00 [Tran[0] BE] [Tran[1] BE]`.
- **Sample stream is BW's segment-rotated block codec verbatim.**
Thor reuses `10 NN` (nibble), `20 NN` (int8), `00 NN` (RLE),
`30 NN` (packed12), `40 02` (segment header) tags with the same
semantics. Channel rotation Tran→Vert→Long→MicL.
- **Geo LSB = 0.0003 in/s** (not BW's 0.005), because Thor's 16-bit
ADC range maps to 10 in/s without the 16-count BW quantization step.
- **Mic ≈ 2.14×10⁻⁶ psi/count** (rough scale; refine after channel
block calibration constants are decoded).
- **BW compliance anchor `\xbe\x80\x00\x00\x00\x00` reappears at
IDFW offset 0x952** — sample_rate at anchor−6 (uint16 BE),
record_time at anchor+6 (float32 BE), same layout as BW.
- **Event timestamp at offset 0x97A** — 8 bytes `[day][month]
[year_be][unk][hour][min][sec]`. Stop-time mirrors at 0x982.
- **Serial as null-terminated ASCII at 0x14E**.
- **Calibration date** at 0x194–0x197 (day, month, year_be).
- Per-sample residual drift of ~3% suggests Thor encodes int8/nibble
deltas with an extra refinement bit that BW doesn't carry —
unsolved; errors resync within a few samples so cumulative impact
is small.
---
## File model
### Filename convention
```
<SERIAL>_<YYYYMMDDHHMMSS>.<KIND>
```
- **SERIAL** — literal device serial, two-letter prefix + numeric
suffix. Examples seen: `UM11719`, `UM13981`, `UM20147`, `BE9439`.
Unlike Series III BW filenames (`M529LK44.AB0`, base-36 stem),
Series IV filenames carry the serial in plain text.
- **YYYYMMDDHHMMSS** — 14-char ASCII timestamp in **device local
time** (no timezone marker).
- **KIND** — `IDFH` for histograms, `IDFW` for waveforms.
The `.IDFH.txt` / `.IDFW.txt` ASCII sidecar lives in a `TXT/`
**subfolder** of the unit's directory, not alongside the binary.
This pairing convention is encoded in
`event_forwarder.idf_report_path()`.
### Directory layout
```
C:\THORDATA\
└── <Project>\
└── <UM####>\ ← unit serial dir
├── UM12345_20260520100000.MLG ← monitor log (not events)
├── UM12345_20260520100000.IDFH ← histogram event (binary)
├── UM12345_20260520100000.IDFW ← waveform event (binary)
├── UM12345_20260520100000.IDFW.CDB ← cache-DB variant (skip)
├── TXT\
│ ├── UM12345_20260520100000.IDFH.txt ← histogram ASCII sidecar
│ └── UM12345_20260520100000.IDFW.txt ← waveform ASCII sidecar
├── CSV\, HTML\, PDF\, XML\ ← operator-facing derived exports
└── ...
```
The `.IDFW.CDB` files share the binary's basename but appear to be a
separate cache/database variant. Their first 8 bytes match the
**old**-firmware Thor signature (see below) regardless of which
signature the paired `.IDFW` uses. Purpose unknown; sizes vary
wildly (observed 123 B → 40,491 B). Thor-watcher's forwarder
deliberately skips them.
### Sample corpus
The `thor-watcher/example-data/THORDATA_example/` tree carries
**1,014 paired .IDFW / .IDFH + .txt files** spanning 2020–2023
across nine units (UM11719, UM13981, UM20147, …, plus BE9439 from
2020). This is the reverse-engineering ground truth.
---
## ASCII sidecar (`.IDFW.txt` / `.IDFH.txt`) — fully decoded
Shape: plain text, one `"Key : Value"` line per metadata field,
followed for waveforms by a tab-separated sample table headed by
the literal line `Waveform Data Channels`. Parsed by
[`micromate/idf_ascii_report.py`](../micromate/idf_ascii_report.py).
See [`micromate/models.py`](../micromate/models.py) for the typed
`IdfReport` shape.
### Notable conventions
- **Units are native to Thor** — geophone in **in/s**, microphone in
**dB(L)** (not psi like Series III BW reports), frequency in Hz,
acceleration in g, displacement in in.
- **Below-threshold readings** appear as the literal string
`<0.005 in/s` (155 occurrences in the sample corpus) — the parser
strips the `<` and treats the numeric remainder as the value.
- **Out-of-range / not-measured** values appear as `N/A` — parser
drops the field rather than letting the string leak into a numeric
column.
- **Firmware string** observed: `Micromate ISEE 11.0AK`.
- **TitleString1..4** are operator-defined free-text slots; Thor's
default labels map them to Location / Client / Company / Notes,
which the parser surfaces as `project` / `client` / `operator` /
`notes`.
- **Histogram sidecars** use `HistogramStartDate` / `HistogramStartTime`
in place of waveform's `EventDate` / `EventTime`. Parser falls
through to either.
- **Histogram tabular block** lacks the `Waveform Data Channels`
marker; instead it's a multi-line column header followed by
per-interval rows (`<date> <time> <tran-ppv> <freq> ...`). Parser
silently ignores lines after the metadata block since they lack a
colon-separated `key : value` shape (the timestamps DO contain
colons but produce garbage keys that don't collide with any
recognised field).
---
## Binary header signatures (observed)
Hex dump of the first 32 bytes across 1,014 sample files reveals
**two distinct file signatures**, both anchored by the literal
ASCII string `"\x00Instantel\x00"` at offset 6–16:
### Signature A — newer firmware (1,012 files, 99.8% of corpus)
```
00000000: 0012 0100 0000 496e 7374 616e 7465 6c00 ......Instantel.
00000010: 0000 a695 002e b500 4f70 6572 6174 6f72 ........Operator
^^^^^^^^^^^^^^^^
operator/title string starts at 0x18
```
Header bytes 0–5: `00 12 01 00 00 00`. Followed immediately by the
8-byte ASCII tag, then 6 unknown bytes, then ASCII operator-supplied
strings (Operator name, etc.) and on through the project / client /
title strings. No `STRT` record observed in this layout.
### Signature B — older firmware (2 files: BE9439 from 2020)
```
00000000: 1000 0180 0000 496e 7374 616e 7465 6c00 ......Instantel.
00000010: 072c 0012 0300 5354 5254 fffe 0111 2340 .,....STRT....#@
^^^^^^^^^ ^^^^^^^^^
STRT magic 4-byte end_key
00000020: 0111 0000 2e5f 00ac 4600 0000 0200 0000 ....._..F.......
^^^^^^^^^ ^^^
4-byte start_key 0x46 (BW WAVEHDR record-type marker)
```
Header bytes 0–5: `10 00 01 80 00 00`. The structure after the
`Instantel` magic is **byte-for-byte identical to a BW SUB 5A
probe-response STRT record** as documented in
[instantel_protocol_reference.md → "SUB 5A — STRT record encodes
end_offset"](instantel_protocol_reference.md). Specifically:
| Offset | Bytes | Meaning (per BW reference) |
|--------|---------------------|--------------------------------------|
| 0x14 | `53 54 52 54` | `STRT` magic |
| 0x18 | `ff fe` | STRT sentinel |
| 0x1A | `01 11 23 40` | `end_key` (4 bytes) |
| 0x1E | `01 11 00 00` | `start_key` (4 bytes) |
| 0x26 | `46` | `0x46` waveform-record type marker |
**Hypothesis:** Older Micromate firmware writes a wrapped BW-format
event into the `.IDFW` file — essentially the same on-disk shape as
a Series III device, with the new filename convention applied at
export time. Newer firmware (signature A) abandoned the
BW-compatible layout for an Instantel-specific format.
If that hypothesis holds, the 2 signature-B files can already be
parsed via `minimateplus/event_file_io.read_blastware_file()` — worth
testing. The 1,012 signature-A files are the real reverse-engineering
target.
### `.IDFW.CDB` cache files
Always carry signature B (`10 00 01 80 ...`), even when the paired
`.IDFW` carries signature A. Plausible explanation: the CDB is an
internal Thor cache-database export that retains the legacy BW-style
record layout regardless of the user-facing `.IDFW` format version.
Not currently consumed by the forwarder.
---
## File-size patterns (Signature A, the main target)
Survey of 1,012 signature-A files:
| Event type | Typical size | Source of variance |
|--------------|-------------------|----------------------------------------------|
| `.IDFW` 2-sec | 9,200 – 10,500 B | Operator-supplied strings (TitleString1..4) of varying length |
| `.IDFH` | 2,944 – 4,076 B | Histogram interval count (record duration / interval) |
**Naive arithmetic for 2-sec waveform:**
- 4 channels × 2 sec × 1024 sps = 8,192 samples
- At 2 bytes/sample (int16) = 16,384 sample bytes → file would be > 16 KB
- Observed: ~9–10 KB
- → samples are likely **1 byte each** (int8 quantised), **or** stored
with bit-packing / delta encoding, **or** only one channel's
full-rate samples are stored with the others reconstructed
arithmetically. Verifying this is the **first RE milestone**.
Project-string–length variance (~1 KB across the corpus) is consistent
with the file carrying a single copy of each TitleString1..4 plus
operator + setup-name as null-padded ASCII regions.
---
## Open questions
The reverse-engineering targets, roughly in dependency order:
1. **Sample encoding (signature A)** — int8? int16 LE/BE? Bit-packed?
Delta-coded? Per-channel interleaved or sequential blocks?
2. **Header field layout (signature A)** — where do sample_rate,
record_time, channel count, and per-channel peaks live in the
binary? The ASCII sidecar gives the device-authoritative values,
so binary fields can be confirmed by diff.
3. **Operator-string offsets** — `Operator` at 0x18 is the first
visible string in signature-A files; the rest (project, client,
notes, setup) follow. Need to map exact offsets and null-padding
conventions.
4. **Signature-B → BW codec compatibility** — does
`minimateplus/event_file_io.read_blastware_file()` actually parse
the 2 BE9439 signature-B files as-is? If yes, the OLD-format
ingest is free.
5. **`.IDFW.CDB` purpose** — is it an internal Thor cache, a
ring-buffer dump, or something else? Worth a single small effort
to characterise so we know what we're skipping.
6. **Footer / checksum** — every BW event file has a footer; does
IDF? Where does the per-channel sample block end?
---
## Reverse-engineering playbook (when we start)
The Series III BW codec took ~2 months of MITM wire captures
because we didn't have ground-truth metadata. Thor's situation is
**substantially better**:
- **Ground truth is on disk.** Every binary in `example-data/`
has a paired `.IDFW.txt` carrying the full decoded sample table
(`Waveform Data Channels` block — see any sample file in
`thor-watcher/example-data/.../TXT/`). Aligning binary bytes
to the table's float-per-row values gives an immediate per-byte
hypothesis test.
- **Cross-event diffing.** 1,012 signature-A samples from 9 units
spanning 4 years means any field that varies between events is
immediately localisable. Fields that are constant across all
files (firmware ID, channel labels, format-version word) are also
immediately localisable by complementary search.
- **No protocol surface.** Files at rest, not a wire dialect. No
DLE stuffing, no inner-frame parsing, no probe/data two-step.
Suggested first session (2-4 hours): hand-decode `UM11719_20231219162723.IDFW`
(10,290 bytes) against its `TXT/UM11719_20231219162723.IDFW.txt`
sample table (the 2-sec waveform at 1024 sps × 4 channels = 8,192
sample rows). Find the first per-channel sample value (`0.0003` in
the Tran column at t=0) in the binary. Confirms sample encoding.
Everything else flows from there.
---
## Code seams ready to receive the codec
When the codec lands, it goes into
[`micromate/idf_file.py`](../micromate/idf_file.py) (currently a
stub raising `NotImplementedError`). Public API:
```python
from micromate import IdfEvent
from micromate.idf_file import read_idf_file
event: IdfEvent = read_idf_file(Path("UM11719_20231219163444.IDFW"))
# event.peaks.transverse_ips, event.timestamp, event.raw_samples, ...
```
The ingest pipeline (`WaveformStore.save_imported_idf`) currently
builds the `IdfEvent` from the `.txt` parser only. Once
`read_idf_file()` works, the binary becomes authoritative; the
`.txt` parser drops to fast-path metadata cross-check. Operators
who don't enable Thor's TXT exporter still get fully populated
events.
---
## See also
- [instantel_protocol_reference.md](instantel_protocol_reference.md) — Series III BW protocol reference (the Rosetta Stone). STRT record format, DLE framing, BW filename encoding.
- [`micromate/idf_ascii_report.py`](../micromate/idf_ascii_report.py) — `.txt` sidecar parser.
- [`micromate/models.py`](../micromate/models.py) — `IdfEvent`, `IdfReport` typed dataclasses.
- [`micromate/idf_file.py`](../micromate/idf_file.py) — placeholder for the binary codec.
- [`thor-watcher/example-data/THORDATA_example/`](../../thor-watcher/example-data/) — 1,014 paired binary + .txt files for codec validation.
File diff suppressed because it is too large. Load diff
-408
View File
@@ -1,408 +0,0 @@
# Spec — a live client for Series IV (Micromate)
Drafted 2026-09-26, ahead of implementation. The protocol work is finished; this
is the plan for turning `docs/micromate_protocol_reference.md` into code SFM can
run.
**Read that document first.** Everything here assumes it, and every constant
below is sourced from it rather than restated with justification.
---
## Goal and scope
`micromate/` is codec-only today — `idf_file.py`, `models.py`, the report
writers. There is no way to talk to a unit. This adds the live half, mirroring
`minimateplus/`.
**In scope, first pass:**
- connect over TCP (a field modem) or serial/USB (a bench unit)
- identify a unit, read its state, clock, memory and setups
- walk the event chain and download events
- return `Event` objects the existing codec already understands
**Explicitly out of scope, first pass:**
- ⚠ **Any write.** Setups, schedules, call-home config, monitoring start/stop,
and per-event delete are all mapped, and none of them will be implemented
here. **No command has ever been originated against a unit by this project**
— every write observed was performed by THOR while we recorded. Keeping that
true through the read client is deliberate: it means the first thing we ever
send to a customer's instrument is a decision someone made on purpose, not a
side effect of a client that happened to grow a method.
- the inbound call-home session — still the one protocol unknown
---
## Layout
```
micromate/
framing.py NEW frame building, response parsing, checksum
protocol.py NEW one method per wire command, returns raw payloads
client.py NEW high-level API, returns models
idf_file.py (existing — decodes what 0x5A returns, unchanged)
models.py (existing — extend, do not fork)
```
**Transport is reused, not rewritten.** `minimateplus/transport.py` is
byte-level and protocol-agnostic — `BaseTransport`, `SerialTransport`,
`TcpTransport`, plus `read_until_idle()` which already handles the RV50/RV55
habit of emitting `\r\nRING\r\n\r\nCONNECT\r\n` to a caller. Import it.
⚠ Do **not** import `minimateplus.framing`. The two framings differ in ways
that look small and are not, and a shared module would accumulate `if series ==`
branches until neither case is readable.
---
## `micromate/framing.py` — ✅ BUILT 2026-09-27
Implemented, with `tests/test_micromate_framing.py` (31 tests, all passing).
**Two things in this section as originally drafted were wrong**, and both were
caught by measuring against the captures before writing code rather than after.
They are left in place below, struck through, because both are the kind of
mistake that would be made again.
### Requests
~~Series IV accepts Series III request frames unmodified. The simplest correct
implementation re-exports the builder rather than duplicating it:~~
```python
from minimateplus.framing import build_bw_frame # ✗ WRONG — 161/218
```
⚠ **`build_bw_frame` reproduces only 161 of Thor's 218 captured read frames.**
The payload layout is identical; the stuffing is not. A Micromate escapes
**four** byte values — `0x02`, `0x03`, `0x04`, `0x10` — where Series III
escapes one. The frames this breaks are **every `SUB 0x5A` download**
(`offset = 0x0400` → a literal `0x04` in `offset_hi`) and the scheduler enable.
An unescaped `0x03`/`0x04` terminates the frame early, so the unit just does not
answer.
`build_request()` with the correct escape set reproduces **218/218**.
✅ **Settled: `0x10` inside params needs no special handling.** The planned
`NotImplementedError` guard is unnecessary — Thor sends
`params = 00 00 10 00 …` on `SUB 0x5A` in five captured frames and the wire
carries an ordinary doubled `10 10`. One rule covers the whole payload.
### Responses — where Series III's parser cannot follow
| | Series III | Micromate |
|---|---|---|
| frame start | `DLE STX` | **bare `STX`** |
| `payload[1]` | `0x10` | `0xC5` (Blastware fw) / `0x03` (Thor fw) |
| destuffing | `DLE+ETX` kept as literal inner-frame data | **`10 XX` → `XX`, uniformly** |
The first row is why `S3FrameParser` returns nothing at all on Series IV traffic:
it scans for `DLE+STX`, which never appears.
The third is a genuine **simplification** — no inner-frame carve-out. Validated
by checksum across every capture in `bridges/captures/9-24-26 - micromate2/`:
four candidate destuffing rules were tried, and only this one makes all frames
validate.
### Checksum
```python
def checksum(payload: bytes) -> int:
return sum(payload) & 0xFF # payload already de-stuffed
```
~~The DLE-aware variant, same as Series III's `5A` and write frames.~~
⚠ **Plain SUM8, not the DLE-aware variant** — 251/251 both directions. The
DLE-aware form is the right answer paired with *Series III* de-stuffing, which
leaves an escaped byte in the payload as two bytes. De-stuffing `10 XX → XX`
already removes the `0x10`, so excluding it again subtracts the correction
twice, and the result disagrees with the wire on **55 of 251** captured
responses — every frame holding a literal `0x10`.
`scratch/mm_frame_parse.py` shipped with exactly that pairing. It looked clean
only because it accepts a frame matching *either* rule, so it labelled those 55
`SUM8` and never flagged one bad. "Zero bad checksums" was true and carried no
information. Fixed there too.
### ⚠ The SUB byte can be escaped
When a SUB's value is `0x02`, `0x03`, `0x04` or `0x10` it arrives as `10 XX`.
Reading it positionally without destuffing reports `0x10`. This bit once
already — `SUB 0x02` was logged as `SUB_10` for an afternoon. Destuff first,
then index.
### Response shape
```python
@dataclass
class MicromateFrame:
sub: int # response SUB; request = 0xFF - sub
flags: int # 0xC5 Blastware line, 0x03 Thor line
page_hi: int
page_lo: int
data: bytes # payload[5:], checksum stripped
checksum_valid: bool
@property
def request_sub(self) -> int: # 0xFF - sub
@property
def page_key(self) -> int: # uint16 BE at payload[3:5]
@property
def firmware_line(self) -> str: # "blastware" | "thor" | "unknown"
@property
def probe_length(self) -> int | None: # uint16 BE at data[3:5] (= payload[8:10])
```
⚠ **`probe_length` is a uint16 BE.** Read as a single byte it under-reads
`SUB 0x1A` by 47x — 44 against a true 2092. This is the single most expensive
mistake available in this protocol and it has already been made once.
Renamed from `declared_length`, because it is **only meaningful in the reply to
an `offset = 0` probe** — and Thor never probes. Across all 251 captured
responses the field reads 0 or a page count, never a length, precisely because
that session is single-step reads throughout. `page_key` is the field that
carries meaning there. The only genuine probe reply we hold is the POLL one
preserved in `scratch/fake_unit.py`.
`MicromateFrameParser` mirrors `S3FrameParser`: `feed(bytes) -> list[frame]`,
accumulates in `.frames`, `reset()`, and keeps the `bytes_fed` counter (it is
what distinguishes "no bytes at all" from "bytes but no complete frame" on a
timeout, and that distinction earned its keep during the Series III work).
---
## `micromate/protocol.py` — ✅ BUILT 2026-09-27
Implemented, with `tests/test_micromate_protocol.py` (35 tests). Reads only;
nothing here writes, erases or changes monitoring state.
The tests replay Thor's captured responses through a scripted transport and
assert **the bytes we emit are the bytes Thor emits** — including a full replay
of the six-event download session, all 56 `0x5A` frames byte-for-byte. That is
a stronger guarantee than "our parser understands the device": a passing test
means a real unit has already answered exactly that frame.
One method per command, returning raw payload bytes. No interpretation — that
belongs in `client.py`.
**Reads use `offset = 0xFFFF`** and return the whole block in one response;
Series III's two-step probe/data dance is unnecessary. `POLL` is the exception,
taking its data length. Per-command offsets, all observed:
| command | SUB | rsp | offset | returns |
|---|---|---|---|---|
| poll | `0x5B` | `0xA4` | `0x0030` | device string, model |
| serial | `0x15` | `0xEA` | `0x000A` | `UM12947` |
| device info | `0x01` | `0xFE` | `0xFFFF` | firmware, calibration |
| state | `0x49` | `0xB6` | `0xFFFF` | `data[11]`: non-zero = monitoring |
| monitor status | `0x1C` | `0xE3` | `0xFFFF` | flag, **device clock**, battery, memory |
| storage range | `0x06` | `0xF9` | `0xFFFF` | event storage extent |
| active setup name | `0x41` | `0xBE` | `0xFFFF` | `TEST1.mmb` |
| first setup | `0x3F` | `0xC0` | `0xFFFF` | setup-list walk head |
| next setup | `0x40` | `0xBF` | `0xFFFF` | …until an empty name |
| compliance config | `0x1A` | `0xE5` | `0xFFFF` | ~2103 B setup block |
| call-home config | `0x2C` | `0xD3` | `0xFFFF` | 137 B |
| arm event | `0x93` | `0x6C` | — | before every event |
| first event | `0x1E` | `0xE1` | `0xFFFF` | key + size |
| next event | `0x1F` | `0xE0` | `0xFFFF` | key + size |
| event record | `0x0C` | `0xF3` | `0xFFFF` | 221 B — project, location, peaks |
| ~~event header~~ **monitor log** | `0x0A` | `0xF5` | `0xFFFF` | ⚠ 297 B, a **walk** — see below |
| bulk download | `0x5A` | `0xA5` | computed | **the `.IDFW` verbatim**, 1024 B at a time |
⚠ **Corrected 2026-09-27, from Thor's frames.** Three rows of the table above
were wrong or incomplete, and the last one is a different command than labelled:
- **`0x0A` is the monitor-log walk**, not a keyed "30 B list record" read. The
*same request repeated* returns successive 297-byte records — serial, mode,
thresholds — until an 11-byte ack ends the list. The device holds the cursor;
nothing in the request selects a record. Series III reaches this data through
a record-type discriminator on its event chain; here it has its own cursor and
the event chain never sees it.
- **`0x1E`/`0x1F` carry token `0xFE` at `params[7]`.** The reference documents
all-zero params (our own probing, which also worked). Thor's form is the one
with mileage.
- **`0x01` has no Thor frame behind it** — it is never read in any captured
session. Its `0xFFFF` comes from our probes.
And one useful negative: **no `SESSION_RESET` (`41 03`)**. Series III needs that
2-byte signal or a monitoring unit will not answer `POLL` over TCP. Thor never
sends it — zero occurrences across 8 sessions, including 40 frames exchanged
with a unit that *was* monitoring.
⚠ **`SUB 0x1C` is 4 bytes longer on the Thor firmware line** (`0x30` vs `0x2C`).
Parse **forward** from `declared_length`, never backward from the end — Series
III reads battery and memory from the end of that block, and doing so on a BD
unit yields a battery voltage of **577.92 V**.
⚠ **Test the monitoring flag for non-zero**, never against a constant. It has
read both `0x0E` and `0x0C` while monitoring.
### `0x5A` — a bounded chunk loop, and much simpler than Series III
⚠ **Corrected 2026-09-27.** This section said "no chunk loop — one request
returns the whole event", with `offset_word = 0x1000 + 2 * ceil(size / 512)`.
That describes our own 2026-09-23 probes, which set `offset_hi = 0x10`. **Thor
chunks**, and Thor's form is the one verified from bytes on disk:
```python
n = ceil(size / 1024) # size from the chain walk
for i in range(n):
offset = min(1024, size - 1024 * i) # a BYTE COUNT
params = key4 + bytes(6) if i == 0 else bytes(2) + pack(">H", 1024*i) + bytes(6)
file_bytes += response.data[11:] # response data is exactly offset + 11
```
Verified on all six bench events (4,076 → 13,424 B): `sum(offsets) == size`
exactly, with the predicted chunk count and final offset every time.
Still no arming ritual for `0x5A` itself, no `STRT` end-offset parsing and no
`TERM` frame — the simplification the original claim celebrated is real, it just
is not single-shot. (`SUB 0x93` arms the *chain walk*, before `1E`/`1F`, not
the download.)
The concatenated payload **is** the `.IDFW` file, byte for byte — so it feeds
`micromate.idf_file.read_idf_file()` and `/db/import/idf_file` unchanged.
⚠ Do not port the Series III `5A` walk. Its address arithmetic caused a 5x
over-read and a `> 64 KB` page-boundary bug that is *still open* on the Series
III side. None of that applies here: the chunk index is a byte offset into the
file, bounded by a size the device told us, and it cannot run past the event.
⚠ **`assert sum(len(chunk) - 11 for chunk in chunks) == size`.** A silently
short event is the failure mode this project has been bitten by repeatedly on
the Series III side, and here the check is free because the size is known up
front.
---
## `micromate/client.py` — ✅ BUILT (read half) 2026-09-27
`connect()`, `get_state()`, `get_active_setup()`, `list_setups()` plus
`MicromateDeviceInfo` / `MicromateState` in `models.py`. 26 tests, every
response constant a real captured data section.
⚠ **`connect()` is deliberately narrower than this spec asked for.** The spec
said to mirror Thor's `POLL → SERIAL → 0x49 → POLL` "because it is known-good".
Measurement showed the four-command form is Thor's *connection check*, present
in 3 of 8 sessions, and its fourth frame repeats its first — so `connect()`
sends the three reads that gather something. `0x01` is not read at all: Thor
never reads it, its layout is unmapped, and `firmware_line` comes free from any
response's flags byte.
Event-chain methods (`list_events`, `download_event`, `get_event`) are step 4
and not yet written; `MicromateProtocol.read_event_file()` already does the
download.
```python
class MicromateClient:
def __init__(self, transport: BaseTransport): ...
def open(self) / close(self) / is_open(self)
# identity and state
def connect(self) -> DeviceInfo # poll → serial → device info → state
def get_state(self) -> UnitState # monitoring?, clock, battery, memory
def get_active_setup(self) -> str
def list_setups(self) -> list[str] # 0x3F → 0x40… until empty
# events
def list_events(self) -> list[EventRef] # 0x93 → 0x1E → 0x1F… (key + size)
def download_event(self, ref) -> bytes # raw .IDFW/.IDFH
def get_event(self, ref) -> Event # download + decode via idf_file
```
`connect()` should mirror THOR's preamble (`POLL → SERIAL → 0x49 → POLL`) —
⚠ but note the reference records that **whether the unit requires it is
untested**. Do it because it is known-good, not because it is known-necessary,
and say so in the docstring.
`list_events()` returns the key *and* the size, because `download_event()` needs
the size to compute its offset word.
---
## Tests
**Offline, from captured bytes — no hardware.** This is the part worth doing
first, because it can be fully verified tonight's-captures-style before any unit
is involved.
```
tests/test_micromate_framing.py
```
⚠ `bridges/captures/` and `tests/fixtures/` are both gitignored, so tests must
not depend on files being present. **Embed the frames as hex constants** — they
are 19–138 bytes each. ✅ Done; what actually landed:
| case | source | why |
|---|---|---|
| POLL probe reply, 19 B | captured (via `fake_unit.py`) | shortest valid frame; the only real probe reply we hold |
| `0x5A` chunk, 138 B | captured | holds literal `0x10` **and** literal `0x41` — the checksum case, and proves ACK is not escaped |
| `0x49` state reply, 25 B | captured | a literal `0x02`, escaped |
| `0x48` file reply, 24 B | captured | escaped `0x04` in `data[0]` — one byte late without destuffing |
| 8 Thor request frames | captured | byte-for-byte against `build_request()`, incl. both `0x5A` forms and the scheduler enable |
| `probe_length = 0x082C` | **synthesised** | no probe reply for `0x1A` exists on disk — the 9-24-26 session never probes |
| Thor-line reply, `flags = 0x03` | **synthesised** | no 11.0BD capture is in the repo; built by flipping one byte of the real POLL reply |
| escaped checksum byte | **synthesised** | the shortest real one is 1,070 B, too long to embed for one assertion |
| truncated / corrupt / split-across-feeds | derived | parser must return nothing, flag rather than swallow, and survive any split point |
⚠ Synthesised frames are marked `SYNTH_`-style in the test and each says what it
stands in for and why no capture was available. Do not let that set grow
quietly: the `flags = 0x03` case in particular is the **only** coverage of half
the fleet, and it deserves a real 11.0BD capture the next time UM20147 is on a
bench.
Two corpus-backed tests run when the captures happen to be on the box and skip
cleanly otherwise: **251 response frames parse with zero bad checksums**, and
**`build_request()` reproduces 218/218 read frames**. The second is the test
that would have caught the escape-set error, so it is worth the skip marker.
⚠ Do **not** assert against `scratch/mm_frame_parse.py`'s output as the original
plan proposed. That script accepts either checksum rule and is wrong about
which one is right — using it as an oracle would have pinned the bug.
**Live, second:** against the bench unit on mint-mac via `mm_link.py`.
`connect()`, `list_setups()` (should return the 23 known names), `list_events()`,
then `download_event()` and assert the bytes decode and match a
`/db/import/idf_file` ingest of the same event.
---
## Order of work
1. ✅ `framing.py` + its tests — **done 2026-09-27**, 31 tests, offline
2. ✅ `protocol.py` + its tests — **done 2026-09-27**, 35 tests, offline
3. ✅ `client.py` + its tests — **done 2026-09-27**, 26 tests, offline
4. the event chain and `download_event()`
5. decode end-to-end and compare against a store event
Steps 1–2 need no hardware at all.
**Worth carrying forward.** Both steps began by measuring against the captures
rather than trusting this document, and both found errors in it — three in the
framing rules (the escape set, 26% of frames; the checksum, 22%; the `0x5A`
chunk model) and three more in the command table (`0x0A`'s meaning, the
`1E`/`1F` token, `0x01`'s provenance). All six fail quietly. The captures are on
disk and a measure-then-write loop costs about two minutes per rule, so keep
doing it for `client.py`'s field offsets — and treat this spec as a plan, not a
source.
---
## Open questions to settle while implementing
- ~~**Request param stuffing**~~ — ✅ settled 2026-09-27; no special handling.
- **Is the single-request `0x5A` form real?** Our 2026-09-23 probes set
`offset_hi = 0x10` and appeared to get a whole 11 KB event back, where Thor
chunks at 1024 B. Plausibly a distinct streaming mode that returns several
frames. One bench test settles it; implement Thor's form regardless.
- **Is THOR's preamble required?** Try one command cold and find out; it is a
two-minute test with the bench unit and it removes a ritual if unnecessary.
- **`Event` model fit** — Series IV carries fields Series III lacks (setup file
name, `LMic`/`SMic` channels). Extend `micromate/models.py`; do not fork the
shared `Event`.
- **Which `0x0C` fields to trust.** The peak float there runs 2–5% above
`max(T,V,L)` and is **not** the vector sum; its offset was inferred, not
established. The reference marks it do-not-rely-on — prefer decoded samples.
File diff suppressed because it is too large. Load diff
-987
View File
@@ -1,987 +0,0 @@
# The "offset" fault — investigation journal
> ## ⚠ CORRECTED 2026-08-28 (same day) — the v1 detector was wrong
>
> Brian pushed back on the finding that offsets "come and go": in the field,
> once a unit develops one it stays broken until the geophone is replaced.
> He was right, and the challenge exposed **two real flaws** in the v1 detector:
>
> 1. **It scored only the axis with the largest peak.** A real event on one axis
> hid a persistent pedestal on another. BE12599 on 2026-08-21 read "clean"
> solely because Long had a 1.065 in/s event — Tran was sitting at
> **+0.4732 in/s** at that moment and was never examined.
> 2. **It used the MEAN**, which a real transient perturbs. The **median** is the
> resting baseline — most samples sit at it, so a blast does not move it.
> Same event, Long channel: mean **+0.0783** vs median **-0.0050**.
>
> Both flaws manufactured false recoveries. The corrected detector
> (`scratch/offset_scan2.py`, per-channel median) shows the pedestal is
> **persistent**, exactly as the field experience says. See §2b and §3b.
>
> **Then Brian proposed a better detector still** — measure the floor during
> the *pre-trigger* window, and require it to hold across pre/middle/end.
> That is now the detector of record (§2c). Final answer: **5 of 45 units
> (11%)**, stable across a 2x threshold range.
>
> Sections below that were written against v1 are marked; v1 numbers are kept
> for the reasoning trail, not as current fact.
A running record of the **offset** hardware fault on Instantel Series III
seismographs: a geophone channel whose trace sits displaced from zero rather
than centred on it.
This is a *journal*, not a spec. Findings are dated, dead ends are kept with
the reason they died, and every number says where it came from. When something
here is superseded, strike it and say why rather than deleting it — the point
is that a future session can tell what was actually established from what was
merely believed at the time.
Companion material:
- `scratch/offset_scan.py` — the detector
- `scratch/verify_against_ascii.py` — decoder verification harness
- `docs/instantel_protocol_reference.md` — wire protocol, incl. the
unimplemented `SUB 0x0E` this investigation now wants
---
## TL;DR (current state, 2026-08-28)
- **It is real device data, not a decode bug.** Settled early and confirmed
against Blastware's own ASCII exports.
- **Base rate: 5–6 of 45 units (11–13%)** across the full DL2 archive,
2018–2026. This *confirms* the earlier 2-of-21 (9.5%) estimate from the much
smaller Terra-View DB — survivorship bias from deleted events had **not**
concealed a wave of cases.
- **The fault is bimodal, not a drift continuum.** A unit is either clean or
grossly off. Loosening the amplitude threshold 11× adds no new units.
- **The unit's own sensor check cannot see it.** 102 offset events, zero
sensor-check failures. Do not try to use it as a screen.
- **Cause is still unsettled.** Instantel's autozero fixes the minority of
cases; the rest are hardware. We cannot yet tell which is which remotely.
- **The histogram corpus (63,535 files, 9.7x the waveforms) is now scanned too** —
see §8b. It independently confirms BE18438 and BE9558 with a clean 2.5x
separation, but detects only **2 of the 5** confirmed units, cannot attribute a
channel, and resolves time to ~a month. **A negative histogram result is not
evidence of health** — DC leakage into the interval peak varies 45x between units.
- **`offset_scan3.py` has a label defect** (§8b): its spread gate discards 18.8% of
high-|pre| rows onto units currently counted as clean. Re-cut before quoting any
precision number again.
- **Best open lead:** `SUB 0x0E` (channel sensor data, 8 channels × 10 bytes,
unimplemented) may carry the very numbers Instantel says to check against
**2027–2069**. Untested.
---
## 1. What the fault looks like
A healthy geophone trace is centred on zero. An offset channel is parked away
from zero, so the channel **mean approaches its own peak**. In Blastware the
signature is "parallel lines above or below the zero line" (Instantel's own
wording).
Consequences observed in the field:
- The unit can **self-trigger on its own offset** when the displacement exceeds
the geo trigger level, producing streams of junk events with no ground
motion. Instantel has a separate FAQ for this symptom (13-0-22, *"Unit
triggers continuously without activity"*).
- Recorded PPV for that channel is meaningless while the fault persists.
---
## 2. The detector
Implemented in `scratch/offset_scan.py`. Operates on raw BW binaries only — no
DB, no sidecars.
```
for each series-3 waveform binary:
decode -> per-channel ADC counts
dominant axis = channel with the largest |peak|
flag when |mean| / peak > 0.70
and |mean| >= 0.90 x the unit's geo trigger level
episodes = per-serial runs of flagged events, split on a >12 h gap
```
Why each term:
| term | purpose |
|---|---|
| `\|mean\|/peak > 0.7` | the discriminator. A DC-parked trace has mean ≈ peak. |
| `\|mean\| >= 0.9 × trigger` | amplitude floor — suppresses quiet traces where mean and peak are both tiny and the ratio is meaningless. |
| dominant axis only | the fault is per-channel; scoring all three dilutes it. |
| 12 h episode gap | separates deployments/visits rather than counting events. |
Trigger level comes from a paired `_ASCII.TXT` when one exists, else the
per-serial median learned from that unit's ASCII files, else 0.2 in/s.
**Known limitation.** Event traces contain real ground motion, so this can only
see offsets large enough to *dominate* the trace. A mild offset on a real blast
is invisible. Instantel's A/D-mode check (§5) is the only thing that sees the
mild end. Our base rate is therefore a **gross-offset** rate.
### 2b. Detector v2 — per-channel median (CURRENT)
`scratch/offset_scan2.py`. Supersedes the above.
```
for each series-3 waveform binary:
for each geo channel independently:
pedestal = median(samples) # resting baseline, robust to blasts
flag the CHANNEL when |pedestal| >= 0.025 in/s (5 A/D counts)
a unit has a real fault when a channel is flagged on >=3 CONSECUTIVE events
```
Why median: a DC pedestal shifts every sample, so it moves the median. A real
event moves only a minority of samples, so it does not. This removes the need
for the `m/p` ratio guard entirely — that guard existed only to compensate for
using the mean.
Why per-channel: the fault is on one geophone axis. Scoring only the dominant
axis means any event with motion elsewhere hides it.
Why "3 consecutive": the 0.025 in/s floor is only ~2x a healthy channel's
resting median (observed 0.010-0.015), so isolated flags are noise. Persistence
is the discriminator — and it is what the field experience predicts.
---
## 3b. Archive results, corrected (v2)
| | v1 (dominant axis, mean) | **v2 (per-channel median)** |
|---|---|---|
| units with any flagged event | 6 of 45 | 19 of 45 |
| **units with a sustained pedestal (>=3 consecutive)** | — | **8 of 45 (18%)** |
| runs of >=3 consecutive | — | 29 |
| runs of 1-2 events (noise) | — | 69 |
Units with a sustained pedestal: **BE9558, BA10895, BE11007, BE11529, BE12599,
BE13117, BE18003, BE18438**. BA10895 and BE18003 were invisible to v1.
**The affected channel is most often Vert**, which v1 got wrong — it named
whichever axis had the largest peak. BE13117 and BE18438 are both Vert faults.
Longest / clearest runs:
| unit | ch | span | events | median in/s |
|---|---|---|---|---|
| BE13117 | Vert | 2023-05-03 → 05-04 | 194 | 0.035 → **1.915** |
| BE18438 | Vert | 2026-02-25 → 02-26 | 75 | 0.180 → 0.370 |
| BE9558 | Vert | 2020-02-11 (6 h) | 33 | 0.065 → 0.090 |
| BE12599 | Tran | 2026-08-14 → 08-23 | 8 | 0.030 → **0.565** |
| BE18003 | Vert | 2021-03-17 → 06-11 | 3 | 0.040 → 0.060 |
BE12599 began **2026-08-14**, not 08-17 as v1 reported, and was still faulting
at the last event in the archive.
### 2c. Detector v3 — PRE-TRIGGER floor + constant-floor test (CURRENT)
`scratch/offset_scan3.py`. Brian's method, and better than v2 for a reason
worth naming: **the pre-trigger window is definitionally quiet** — it is the
buffer captured before the trigger fired — whereas a whole-record median is
merely *robust* to the event. `pretrig_samples` comes from the STRT record.
```
per channel:
pre = median of the first pretrig_samples samples
mid = median of the middle third
end = median of the final third
spread = max(pre,mid,end) - min(pre,mid,end)
offset when |pre| >= floor AND spread <= 0.02 in/s
real fault when a channel is flagged on >=3 CONSECUTIVE events
```
A DC offset is a **constant floor** — present before the trigger, during, and
after. The spread test rejects transients (settling, handling, a long event
tail) that move one segment relative to the others, which is what v2's
whole-record median could not do.
**The empirical noise floor justifies the threshold.** Across 19,244
non-flagged channel-events the pre-trigger floor distributes as:
| floor | share |
|---|---|
| −1 unit (−0.005) | 18.4% |
| **0.000** | **62.7%** |
| +1 unit (+0.005) | 13.4% |
**94.5% within ±1 quantisation unit; median exactly +0.0000, mean −0.0008.**
So there is **no systematic zero-point bias in the decoder** — an independent
confirmation of the 32000-count scale. A healthy channel really does read
0.000, and "any constant floor that is not 0.000" is the right signal, with
±1 unit of slack for quantisation.
**The result is threshold-insensitive**, which is what distinguishes a real
signal from a tuned one:
| floor | units flagged | sustained units |
|---|---|---|
| 2 units (0.010) | 34 | 15 ← into the noise |
| 3 units (0.015) | 26 | 8 |
| **4 units (0.020)** | 17 | **5** |
| **5 units (0.025)** — Instantel's | 12 | **5** |
| **8 units (0.040)** | 8 | **5** |
### FINAL RESULT: 5 of 45 units (11%)
**BE9558, BE11529, BE12599, BE13117, BE18438.**
Unchanged across a 2x threshold range. BE11007 and BA10895 drop out — the
spread test identifies them as transients, not pedestals.
The 11% headline happens to match v1's, but the reasoning and the unit list
differ: v1 included BE11007 and named the wrong *channel* on most units.
---
## 3. Archive results (2026-08-28)
Source: DL2 event export, 6,577 **unique** series-3 waveforms, 45 units.
See [`dl2-archive`](#8-data-and-tooling) for the `Sent/` mirror trap.
**283 suspect events, 15 episodes, 6 of 45 units (13.3%).**
Excluding BE11007 (§4, likely not an offset at all): **5 of 45 = 11.1%**.
### Threshold sensitivity — the bimodality result
Re-scoring the same corpus at a range of amplitude floors, with two
ratio cut-offs (1 A/D count = 0.005 in/s, see §5):
| \|offset\| floor | m/p > 0.7 | m/p > 0.9 |
|---|---|---|
| 5 cts (0.025 in/s) — *Instantel's own* | 333 ev / 6 units | 279 ev / **5 units** |
| 10 cts (0.050) | 294 / 6 | 274 / 5 |
| 20 cts (0.100) | 250 / 5 | 244 / 4 |
| 40 cts (0.200) | 209 / 5 | 203 / 4 |
| 80 cts (0.400) | 152 / 4 | 148 / 2 |
| 160 cts (0.800) | 144 / 2 | 141 / 1 |
Relaxing the floor by 11× (0.27 → 0.025 in/s) adds ~14% more events and **no
new units**. There is no population of mild offsets hiding below our threshold
*in event data*. Either a unit is clean or it is grossly off.
---
## 4. Per-unit case files
Ordered by severity. `m/p` medians are on the offending channel.
### BE13117 — one violent day, never again
`145 / 454 events (32%)`, **1 episode**, 2023-05-04, 6.8 h.
Offset climbed **0.393 → 1.875 in/s within the episode**. `m/p` median
**0.996** — the trace is almost pure DC. No recurrence in the rest of its 454
events. No ASCII files in the archive, so no calibration history.
### BE18438 — recurring, months apart
`87 / 293 (30%)`, **2 episodes**: 2025-11-15 (1.2 h, n=12, 0.279 → 0.369) and
2026-02-25 (**28.8 h**, n=75, 0.183 → 0.366). `m/p` median 0.967.
Clean across all 196 events preceding its 2025-08-12 calibration.
### BE9558 — six years apart
`38 / 196 (19%)`, **4 episodes**: 2020-02-11 (6.3 h, n=33, but only
0.068 → 0.086 — very mild), then 2026-04-14, 2026-04-29, 2026-05-04
(0.28–0.45). `m/p` median 0.919. Calibrated 2026-06-26; 0/7 events flagged
after, but n=7 is far too small to call it fixed.
### BE12599 — the live case ⚠
`6 / 77 (8%)`, **6 single-event episodes, one per day at exactly 05:00**,
2026-08-17 → 2026-08-23. Offset rose 0.383 → 0.565 then fell back to 0.345.
`m/p` ≈ 0.965, geo trigger 0.3 in/s — **the offset exceeds the trigger level,
so the unit is triggering on its own fault**. Last calibrated 2025-08-12.
This is the most recent and the most useful: a currently-faulting unit is the
natural experiment for the re-zero-vs-repair question (§7).
### BE11529 — marginal
`4 / 99 (4%)`, 1 episode 2025-07-08, 0.4 h, offsets only 0.051 → 0.058 in/s.
`m/p` median 0.959, so DC-dominated, but the magnitude is near the noise of
this method. Treat as unconfirmed.
### BE11007 — probably NOT an offset
`3 / 70 (4%)`, 1 episode 2022-01-17, offsets 5.500 → 6.904 in/s — by far the
largest. But `m/p` is only **0.719–0.738** against ≥0.9 for every other unit,
and the peaks are 7.6–9.4 in/s on a 10 in/s range. That reads as a **large
real blast with asymmetric ground motion**, not a parked trace. Excluded from
the headline base rate.
---
## 5. Instantel's own procedure and thresholds
From two Instantel technical-support FAQs supplied 2026-08-28
(answers **13-0-21** *"How to determine offsets"* and **12-0-10** *"Removing
offsets on an Instantel Series III monitor"*; created 2008/2007, last updated
2009-03-06).
### Identifying (13-0-21)
1. Create or use an event with the **manual minimum trigger** set for the
connected geophone and microphone — i.e. an event that recorded no real data.
2. Save it and open in Blastware.
3. An offset shows as **parallel lines above or below the zero line**.
4. Put the unit in **A/D mode** — on Series III, press and hold `OPTION`, then
press `START MONITOR`.
5. **Display counts higher than 5**, with no vibration or overpressure present,
indicate an offset.
### Removing — the autozero (12-0-10)
1. Be in a **quiet area with low vibration**.
2. Power on the Blastmate III / Minimate Plus.
3. Connect the geophone and microphone — **LINEAR mic only**.
⚠ *Do not connect an "A" weight microphone, regardless of what the monitor
displays.*
4. Press `Test`.
5. Wait for the **Sensor Check** results to appear.
6. Press `OPTION` and `START MONITOR` **simultaneously**.
7. `Performing Autozero` appears; press `Enter`.
8. Confirm the sensors are properly connected; press `Enter`.
9. Wait for the autozero to complete.
10. Press `Enter` twice → Main Menu, *Ready To Monitor*, offset corrected.
### The go/no-go number — 2027 to 2069
> When you perform an Autozero on any Series III unit, the lists of numbers in
> the **X1 and X8 gains should all be between 2027 and 2069**. If not, repeat
> the Autozero. **If the numbers are extremely out of the specified range, then
> the unit should be sent in for repair.**
>
> If this process does not remove the offset problem, return the unit **and
> sensors** to Instantel for repair.
This is the documented explanation for the field experience (Brian's dad,
2026-08-28) that **a re-zero works maybe 10% of the time** — the autozero only
recovers units whose zero reference is still near-correct.
### Scale derivation (inference, well-supported — not proven)
2048 is 12-bit midscale. Our codec's geo full scale is 32000 internal counts =
10 in/s, with 1 decoder unit = 16 counts = exactly 0.005 in/s
(`geo-full-scale-is-32000-counts`). ±2000 A/D counts about 2048 therefore maps
to ±10 in/s at **0.005 in/s per A/D count**. That makes:
- Instantel's ">5 counts" threshold ≈ **0.025 in/s**
- the 2027–2069 window = **±21 counts = ±0.105 in/s** of tolerated zero error
Consistent and mutually corroborating, but we have not confirmed the A/D-count
scale directly from a device reading.
---
## 6. Ruled out — keep these dead
### Condensation / humidity — DEAD (2026-08-25)
Proposed, then killed by its own controls: BE18438 stayed flat across a 10-hour
overnight gap, and only 2 of 21 units showed the fault while 19 sat in the same
weather. The apparent "diurnal cycle" was an artifact of binning by hour-of-day
across two days. See `waveform-dc-offset-is-real-device-data`.
### Clipping as a false-positive source — RULED OUT (2026-08-28)
A rail-hitting trace would fake an offset (mean → peak). It isn't happening:
median suspect peak is only **10% of full scale**, p90 is 18.6%. Only BE11007's
3 events exceed 50% FS, and none reach 98%.
### The sensor check as a predictor — DOES NOT WORK (2026-08-28)
Tested on 102 offset events across 4 units:
| unit | state | n | failed | median ratio | median freq |
|---|---|---|---|---|---|
| BE11529 | offset | 4 | **0** | 3.90 | 7.6 |
| BE11529 | clean | 14 | 0 | 3.80 | 7.5 |
| BE12599 | offset | 6 | **0** | 4.00 | 7.4 |
| BE12599 | clean | 13 | 0 | 4.00 | 7.6 |
| BE18438 | offset | 87 | **0** | 3.70 | 7.6 |
| BE18438 | clean | 25 | 0 | 3.80 | 7.5 |
| BE9558 | offset | 5 | **0** | 3.90 | 7.8 |
| BE9558 | clean | 44 | 0 | 3.80 | 7.5 |
Zero failures on either side and indistinguishable ratios/frequencies. The
swing test measures geophone frequency response and damping — it never examines
DC zero. **A grossly offset unit passes its own self-check.** This is why the
fault goes unnoticed until somebody looks at waveforms.
### "Offsets are transient / come and go on their own" — RETRACTED 2026-08-28
v1 reported episodes lasting hours that ended spontaneously. **This was an
artifact of the v1 detector** (see the banner at the top). With the per-channel
median, the pedestal persists. Every clear case reads clean again only after a
multi-day-to-multi-month gap consistent with service: BE13117 6 days, BE18438
24 days, BE9558 63 days **with a confirmed Instantel calibration inside the
gap**. BE12599 never reads clean — it is still faulting at the end of the
archive. This matches the operational experience: once a unit develops an
offset it stays broken until the geophone is replaced.
### "Offsets develop N months after calibration" — CONFOUNDED, NOT A FINDING
Tempting, and it looked strong:
| unit | suspect before latest cal | after |
|---|---|---|
| BE18438 | 0 / 196 | 87 / 97 |
| BE12599 | 0 / 62 | 6 / 15 |
| BE11529 | 0 / 82 | 4 / 17 |
| BE9558 | 38 / 189 | 0 / 7 |
But bucketing suspects by months-since-calibration gives **one unit per bucket**:
`0–3mo={BE11529}`, `3–6 & 6–9mo={BE18438}`, `9–12mo={BE9558}`,
`12–15mo={BE12599}`. The apparent "51% failure rate at 6–9 months" is entirely
BE18438's single February 2026 episode. Five units with roughly one episode
each cannot support a population trend. **Do not re-derive this.**
Also note: all affected units are calibrated on a **~12–13 month cadence**, so
"sent to Instantel" is the routine annual schedule, not evidence of a
fault-driven return.
---
## 7. Open questions
### Q1 — Is it a latched bad zero or analog degradation?
The question that decides everything. A latched zero is correctable (possibly
over the wire); degradation means a repair. Instantel's 2027–2069 rule implies
*both* populations exist, with the split roughly 10/90 in the field.
**BE12599 is the natural experiment** — faulting as of 2026-08-23. Read its
values, run the autozero, read them again.
### Q2 — Can we read the autozero numbers over the wire? (best lead)
Instantel says to check *"the lists of numbers in the **X1 and X8 gains**"* —
4 sensors × 2 gains = **8 channels**. The protocol reference already documents
an unimplemented command with exactly that shape:
```
SUB 0x0E -> RSP 0xF1 "channel sensor data"
2-step read; channel selector in params[6:8] = 0x0000..0x0007
data length 0x0A (10 bytes) per channel
```
Blastware's *Unit Channel Test* sequence:
`POLL×N → 0x15 → 0x01 → 0x08 → 0x01 → 0x0E×8 → 0x98×2 → 0x0E×8`
— note the **second `0x0E` pass carries live ADC readings**.
**Hypothesis (untested):** `0x0E` returns the numbers Instantel wants compared
against 2027–2069. If true, SFM could diagnose an offset remotely *and* predict
whether a re-zero will succeed — converting a 10%/90% shipping gamble into a
decision made before packing a box.
**How to test.** `bridges/ach_mitm.py` is a generic TCP proxy:
```bash
python bridges/ach_mitm.py --bw-host <MODEM_IP> --bw-port 9034 --listen-port 9999
```
Point Blastware at the proxy and run **Unit Channel Test**.
⚠ In this topology the output filenames are reversed — the tool labels the
*connecting* side "unit", so `raw_s3_*.bin` holds Blastware's bytes and
`raw_bw_*.bin` the unit's.
Capture priority: (1) BE12599 while faulting, (2) a known-good unit as control,
(3) before/after an autozero on the same unit. Eight 10-byte payloads with an
expected value near 2048 is a very constrained puzzle.
### Q3 — What is the mild-offset rate?
Unmeasurable from event files (§2). Only the A/D-mode check sees it. Would
need a fleet sweep in A/D mode, or Q2 to succeed.
### Q4 — Does an offset recur on the same unit after service?
BE9558 shows episodes in 2020 and 2026; BE18438 twice in four months. Suggestive
of recurrence, but service records aren't in the data — only calibration dates.
---
## 8. Data and tooling
| what | where |
|---|---|
| detector | `scratch/offset_scan.py` |
| current results | `/home/serversdown/dl2-archive/offset_archive.csv` |
| earlier candidate list (Terra-View DB, 274 events) | `scratch/offset_candidates.csv` |
| archive working copy | `/home/serversdown/dl2-archive/files/` |
| archive source | NAS `DeathStar` 10.0.0.2, `/volume1/Uploads/TMI/DL2-Event-backup-8-25-26/Event/autocall home/` |
⚠ **The DL2 export keeps a byte-identical `Sent/` mirror of its root.** 13,077
waveform paths are 6,577 distinct files. Always dedupe by basename — this
doubled two reported figures before it was caught.
---
## 8b. The histogram corpus — the other 90% of the archive (2026-09-04)
Every result above §8 comes from **waveform** files. `offset_scan3.py` filters on
`\.[A-Za-z0-9]{2}0[Ww]$`, so the corpus it scanned is 6,577 unique binaries. The
archive also holds **63,535 unique histograms** — 9.7x more files — which the
pre-trigger method cannot touch, because a histogram carries no samples: only a
per-interval, per-channel peak and half-period.
`scratch/offset_hist_scan.py` scans them. **63,505 of 63,535 decoded (99.95%),
43 units, 77.9M intervals.** Two of the 45 units have no histograms at all.
Output: `/home/serversdown/dl2-archive/offset_hist.csv` (190,515 channel-rows).
### The premise, and how far it actually holds
A histogram file is hours of continuous monitoring, so most of its intervals are
definitionally quiet, and a channel parked off zero cannot report a peak below
its own displacement. The signal is real — two within-unit contrasts, siblings
unmoved in both:
| unit | channel | in-episode floor | outside | waveform \|pre\| same window |
|---|---|---|---|---|
| BE18438 | Vert | 0.0350 | 0.0050 | +0.18 .. +0.37 |
| BE12599 | Tran | 0.0250 | 0.0050 | +0.03 .. +0.49 |
But the **leakage from a waveform pedestal into the histogram floor is bimodal,
not merely partial**: measured ratio ~0.9 on BE18438 Vert, ~0.7 on BE9558,
**~0.02 on BE12599** — two orders of magnitude on one instrument. The device
evidently measures each interval peak against a running baseline, and how much
DC survives that varies per unit. **Consequence: a negative histogram result
carries almost no information.** Do not read "clean in the histograms" as clean.
### The detector that survived
dmin(file, ch) = min[ch] - min over the other two geo channels, SAME file
gates (both hard): n_intervals >= 60 AND mic_p5 <= 5 raw counts
day statistic: median of dmin over that day's qualifying files
flag day at dmin >= 0.020 in/s (4 A/D counts)
episode at >= 3 CONSECUTIVE observed days
**Result: BE18438|Vert, BE9558|Tran, BE9558|Long.** Threshold-insensitive —
the journal's own test for a real signal against a tuned one — and this is the
first operating point in the investigation that passes it cleanly. The identical
answer holds across: statistic `min` or `p5`; length gate 10/30/60/120/300; mic
gate 3/5/8/10; threshold 0.015–0.035 (a 2.3x span); persistence K = 2,3,4,5,7.
Separation, ranked by highest floor sustained over 3 consecutive gated days
across all 135 unit-channels:
| unit-channel | best3 |
|---|---|
| BE18438 Vert | 0.1650 |
| BE9558 Long | 0.0350 |
| BE9558 Tran | 0.0250 |
| *(2.5x gap)* | |
| BE7145 Tran | 0.0100 |
| entire rest of fleet | <= 0.0050 (one quantisation count) |
Day-level false alarm: **37 of 99,432 gated unit-channel-days = 0.037%.**
### What it does NOT do — read this before trusting it
- **It finds 2 of the 5 confirmed units, not 5.** The site-quiet gate is what
makes it work and it is also what costs BE11529 and BE12599. BE11529's
four-day single-axis ramp (Tran 0.025 -> 0.055, both siblings pinned at 0.005)
is the most offset-shaped thing in the corpus outside the two detections, and
the gate discards it.
- **The positive class is two units.** Every threshold here is fitted to
BE18438 and BE9558, which contribute 22 of the 37 flagged days in the entire
corpus. No cross-validation is possible at n=2.
- **Per-channel attribution is NOT established.** Rotating the three geo channel
labels within each file — preserving every value, file and day, destroying
only channel identity — reproduces the episode *count* with p = 0.769 and the
label agreement at p = 0.038–0.077. Report a **unit and a window**; do not
name a geophone axis on the strength of this detector alone.
- **Timing resolution is ~1 month, not ~1 day.** A 30-day label shift still
scores 2 of 9 episode hits; the signal dies only past ~60 days. The day-level
series look far crisper than they are.
- **Ground truth here is a sibling detector, not a service record.** Agreement
between the two corpora is corroboration of a shared method. Nothing in this
section has been checked against an actual repair, calibration or RMA.
### Dead ends — keep these dead
- **Absolute floor (min / p1 / p5 / p10 / p25, thresholded alone) — RETIRED.**
Not fleet-comparable and mostly not about the channel. Scoring each cell using
*only the other two channels* — a statistic containing zero information about
the suspect channel — reaches AUC 0.746 against the same labels, versus 0.872
for the absolute floor itself. **66% of its apparent discrimination is "that
day was noisy at that site."** Interval size alone moves its p99 7x (0.0350 at
1 min vs 0.0050 at 2 s). And of all files with any channel above 0.025, 56.5%
have **all three** channels above it — common-mode, i.e. the wrong physics.
- **Zero-fraction — STRUCTURALLY IMPOSSIBLE, not merely weak.** The device never
reports a zero histogram interval peak. The value is a max over hundreds of
samples of a channel that always carries at least 1 count of noise, so it is
clamped at 1 A/D count (0.005 in/s). There is no zero to count.
- **Interval size, sample rate, geo range, firmware — refuted as confounds for
the differential.** All four are *file-level scalars*: they move all three geo
channels together, so they cannot produce a single-channel lift and the
within-file differential is immune to them by construction. Geo range is
identical across the three geo channels in **63,535 of 63,535** binaries.
(Interval size remains fatal to the *absolute*-floor version, above.)
### Two findings that are independent of the histogram detector
**1. `offset_scan3.py`'s `spread <= 0.02` gate is discarding real signal.**
It rejects **113 of the 600 channel-rows with |pre| >= 0.025 (18.8%)**, and the
rejections are not random — 92 of them fall across 41 unit-channels currently
labelled NEGATIVE. Four would become sustained positives under an
amplitude-only >=3-consecutive rule: **BE12599|Long (run of 8), BE18003|Vert
(4), BA10895|Vert (3), BE12844|Tran (3).** Until this is re-cut, the fleet label
is **three-state — POSITIVE / NEGATIVE / SPREAD-REJECTED(unknown)** — and the
third state should be excluded from both TP and FP counts rather than silently
scored as healthy. Every precision figure computed against the two-state label,
in this section and in §3, is affected.
**2. The waveform corpus sees ~7% of the days a unit was deployed.** 2,627
(unit, day) observations against the histogram corpus's 35,105 — 13.4x — with a
per-unit median ratio of 0.070. BE12599, a confirmed unit, is waveform-observed
on 39 of its 1,666 histogram-observed days (**2.3%**). Any statement of the form
"the fault was absent before date X" that rests on waveform coverage alone is
much weaker than its event count suggests.
### BA10895 — reclassified (see also §4)
Previously dismissed as a transient. The histogram record shows its **Vert**
quiet-minute floor at 0.005 on 62/62 qualifying files from 2023-07-07, then
0.010–0.015 on 48/58 files from 2023-08-03 to 08-27, while Tran moves on 2/58
and Long on 9/58 and the site mic floor never leaves 1–3 counts. Independently,
**42 of its 85 waveform events (49.4%) are single-axis-dominant** — one geo peak
>= 10x both siblings and >= 0.05 in/s — the **highest rate in the 45-unit
fleet** (BE13117 36.1%, BE18438 29.4%), and **100% of it on Vert**. Vert
excursions of 0.1–1.5 in/s with Tran/Long at 0.005–0.035 are not ground motion.
This is a genuine Vert-channel hardware fault, but **not the classic pedestal** —
the differential is only one A/D count. Caveat: its entire histogram record is a
single 52-day deployment ending 2023-08-27, so nothing says whether it
persisted, was serviced, or resolved.
The other six marginal units — BE11007, BE17354, BE18004, BE18104, BE9557,
BE18003 — are **clean**. All seven cap at +0.005 to +0.007 (one A/D count)
lifetime under the quiet-site gate, against +0.175 for BE18438 Vert and +0.062
for BE9558 Long. Three individual waveform flags fall in windows with **zero**
histogram coverage and are NO-DATA, not clean: BE18004|Tran 2024-10-16,
BE9557|Tran 2021-06-28, BE9557|Vert 2025-06-12.
### Still open in this section
- **The 11 thin-coverage units were not screened** (BE10202, BE11462, BE13779,
BE15760, BA15957, BE16754, BE16758, BE8081, BE8626, BA9229, BE9887 — each
under 20 waveform events, several with hundreds of histograms). This is the
population most likely to hold a previously unknown offset, and it is the one
slice of the plan that did not run. BE11462 was incidentally scored clean by
the full-archive pass; BE10202 has no histogram files at all.
- **No completeness audit was run** over the above.
- Re-cutting the ground truth three-state (finding 1) and re-scoring everything
against it.
---
## 8c. Mechanism — five hypotheses tested, all dead (2026-09-06)
**The mechanism is still unknown.** Five campaigns, ~105 effectively independent
tests, seven nominally significant results against **5.2 expected by chance**
under a global null. Every one died to its own confound analysis. What the
campaign bought is a set of *shape constraints* and a long list of dead ends.
### ⚠ Two things retracted from this journal
**1. "Polarity is perfectly consistent — 11 of 11, zero mixed cases."** That is
a **tautology of the spread gate**, not a property of the fault. `spread <= 0.02`
requires pre/mid/end to agree, which forces one sign. Amplitude-only at the same
0.025 threshold: **12 of 53 unit-channels are mixed**, including BE18438|Vert
(88+/1−) and BE9558|Vert (1+/35−). Withdrawn.
**2. "5 of 45 units, unchanged across a 2x threshold range."** The
threshold-insensitivity is also a property of the gate. Amplitude-only gives
**9 units at 0.020, 8 at 0.025** (adding BA10895, BE12844, BE18003), 5 at 0.040.
The fleet is **8–9 units, not 5**.
**3. "Persistent — it stays until the geophone is serviced."** Weakened, not
withdrawn. There are **23 recoveries after runs of >=3 flagged events, median
gap 6.03 days**, three inside ten minutes. BE18438|Vert reads `pre=mid=end=
+0.0000` on 2026-02-10, +0.185→+0.370 across 02-25/26, and `+0.0000` again on
2026-03-22 — identical Project, Seis Loc, calibration date, geo range and
trigger throughout. The one thing that cannot be excluded is a **field
autozero**: it is a button sequence at the unit and writes nothing into the
event header. So "persistent" may be "persistent unless somebody pressed the
buttons," and the archive cannot tell those apart.
### The one positive finding: onset is a RAMP, minutes to hours
Both onsets resolvable at minute cadence are ramps. **BE18438|Vert,
2026-02-20** — the histogram corpus collapses a 14 d 21 h waveform bracket to
**one minute**:
```
~14,200 consecutive quiet minutes at 0.000–0.005 (ten full daily files)
09:32 +0.005 09:39 +0.045 10:20 +0.125 16:00 +0.165
09:33 +0.010 09:42 +0.070 13:13 +0.150 20:17 +0.185 plateau
```
**50% of the excursion in 7 minutes**, the rest asymptotic over ~10 h, **>=25
distinct one-minute intermediates**. Validated **75/75** against Blastware's own
ASCII export. Its 2025-11-15 onset is the same shape over 2.7 h. BE13117 stage B
is a 91-minute monotone rise, +0.035 → +1.745 in/s over ~40 samples.
**This kills both poles of the original dichotomy** (journal Q1): not an
instantaneous latched step (a bad autozero, a stuck trim-DAC), and not slow
component degradation over days or weeks.
⚠ It rests on **2 of 45 instruments**. Clopper-Pearson on 4/4 resolved onsets
gives 95% CI [0.40, 1.00] — a mixed population with up to 60% true steps is not
excluded. BE13117 has zero paired ASCII, so its ramp rests on our decoder alone.
### The methodological corollary — more important than the finding
**A waveform-only bracket manufactures the appearance of a step, and the spread
gate is blind to onsets by construction.**
The offset is what fires the trigger, so no waveform event can exist until the
ramp has nearly reached the trigger level. BE18438's first event of each episode
sits at 0.280 against a 0.300 trigger, and 0.185 against 0.200. At daily cadence
against a 3 h ramp, P(catching an intermediate) = **0.125**.
And `spread <= 0.02` rejects any record in which the floor is *moving* — which
is exactly what an onset is. **The gate rejected the very BE18438 record where
the ramp is visible.** If the operational goal is catching a fault early, before
the unit floods the store with junk events, the current detector is the wrong
shape for the job.
### The surviving shape
An **electrical, reversible, two-time-constant settling process** (~10 min and
~hours), saturating at a ceiling, with occasional sub-3-minute discrete jumps
superposed (BE18438 2026-02-26: 13:24 pre +0.180 / mid +0.240 / end +0.255 →
13:27 +0.325, identical metadata). That is the signature of a **bias or leakage
path charging a high-impedance node** — the class of fault Instantel's autozero
recovers ~10% of the time, and what the X1/X8 gains measure.
**It is a shape constraint, not a mechanism. Do not write it up as one.**
### Dead — with the evidence, so none of this is re-derived
| Killed | Evidence |
|---|---|
| **Latched step at onset** | >=25 one-minute intermediates over ~10 h, ASCII-validated. Direct observation, not a test. |
| **Slow degradation over days/weeks** | Same observation — bulk of the excursion in 7 min to 2.7 h. |
| **Thermal driving of pedestal magnitude** | BE13117, 365-count pedestal, n=128: full-day modulation **−0.42% ± 0.42%**, 95% CI [−1.25%, +0.40%]. Healthy-fleet seasonal zero drift totals **~0.3 A/D counts** — 15x to 1200x too small. Best-powered result in the campaign. |
| **Ground-motion shock** | 30-day window-max percentile ranks 0.03/0.98/0.15/0.01/0.68/0.24, median **0.194** against a null of 0.5. **0 of 7 events >=9 in/s** was followed by an onset within 30 d. BE12599 hit 10.220 in/s (2023-11) and 10.005 (2025-04) and did not onset until 2026-08-14. |
| **Handling / redeployment** | **0 of 9** onsets had a Project/Client/Seis Loc change. Widened to 30 d: 2 observed vs 4.90 expected, P(X>=2)=0.995 — *depleted*, the wrong direction. The apparent gap effect (p=0.035) died on histogram coverage: BE18438's "59.7-day gap" contains 122 histogram files; true silence 0.52 d. |
| **Mechanical resonance / damping change** | BE18438|Vert at a 64-count pedestal (3x outside Instantel's ±21): ΔTest-Freq **CI [−0.090, +0.021]** against 0.127 Hz for a real calibration. Block permutation p=0.658. |
| **Accumulated-duty threshold** | ~4 clean units logged more monitoring than the largest positive onset dose; BE18193 logged **13.45M intervals, 6.2x**. A counterexample — no power argument weakens it. |
| **Firmware** | **14,338 of 14,340** exports read `V 10.72-8.17`. A constant cannot explain a variable. |
| **Unit age** | Serial rank-sum 118.0 vs null 115.0, p=0.549; unchanged on the 8-unit re-cut (p=0.586). Serial is a poor age proxy anyway (Spearman +0.113 against archive entry). |
| **Strong seasonal clustering** | 25 onsets, exposure-weighted permutation **p=0.59**. Excludes >=75%-in-one-season only; a 2x seasonal hazard is *not* excluded. |
Also retire two overstated bounds. H6's dose-response exclusion "|r| > 0.03" is
a **10x overstatement** once clustering is corrected — the honest bound is
|r| > 0.1–0.3, so a real r=0.2 is not excluded. And **any statistic quoted
per-event**: 512 flagged channel-events collapse to **4.9 effective independent
observations** (unequal-cluster design effect 104.6 at ICC=1), and **55% of the
flagged corpus is one instrument on two calendar days** (BE13117, 2023-05-03/04).
### Power — read every negative in this section as bounded
Fisher exact, 5 positives of 45, one-sided α=0.05, exposure a third of the fleet:
| relative risk | power |
|---|---|
| 1.5 | 0.059 |
| 2 | 0.112 |
| 3 | 0.231 |
| 6 | 0.497 |
| 15 | 0.753 |
80% power needs **RR ≈ 13–20**. Even a *perfect* split reaches p<0.05 only if
the exposed group is <=25 of 45 units. **This archive can detect only
near-deterministic unit-level causes.** Every negative above excludes a strong
effect, not a real one.
### What this archive can NEVER answer
- **The A/D zero and the X1/X8 gains.** The 2027–2069 numbers appear in no file,
header or decoded record. They exist only on a live device behind `SUB 0x0E`.
Q1 is structurally unanswerable from data.
- **Unit-level vs component-level cause.** **Zero of 14,340** exports carry a
geophone or sensor serial. Q4 is dead — there is no way to know whether the
same physical geophone came back after service.
- **Service history.** The only service-adjacent field is `Calibration: <date>`
— 30 distinct dates fleet-wide, none before 2023, ASCII corpus entirely
2025–26. BE9558's 2020 and BE13117's 2023 episodes have no calibration record.
- **Temperature.** Zero exports carry it. Battery Level is a verified coarse
thermometer (+0.204 V winter over summer, 20/20 unit-years, p=9.5e−7, matching
lead-acid tempco) but quantised at 0.1 V ≈ 10 °C — useless within a day. The
archive can *bound* thermal; it can never *test* it.
- **BE13117 specifically** — 55% of the flagged corpus, the largest pedestal at
1.92 in/s, **zero** ASCII exports, histogram record ending eight months before
its episode. The most informative case in the archive is permanently outside
every metadata test.
- **The mild-offset rate**, and therefore the base rate's denominator. Event
files only see offsets large enough to dominate the trace.
### The experiment to run — `SUB 0x0E`, one afternoon
Point Blastware at `bridges/ach_mitm.py` and run **Unit Channel Test** against
(1) a faulting unit, (2) a known-good control, (3) the same unit before and
after an autozero. BW's sequence is `0x0E x8 → 0x98 x2 → 0x0E x8`, the second
pass carrying live ADC. Eight 10-byte payloads with expected values near 2048 is
a very constrained puzzle.
- **Proves:** whether the X1/X8 gains are readable over the wire, and whether
the fault sits at or upstream of the ADC zero reference. Gains walk out of
2027–2069 with the pedestal → the fault *is* the zero reference, Q1 answered.
Gains hold while the trace moves → the fault is downstream, look at the front
end.
- **§8c hands it a falsifiable time course:** poll at ~1-minute cadence and the
numbers should **ramp over minutes-to-hours, not step**. If they step while
the trace ramps, the two are decoupled.
- **Payoff:** converts the 10%/90% ship-it-or-not gamble into a decision made
before packing a box, remotely, for the whole fleet.
- ⚠ In the MITM topology filenames are reversed — `raw_s3_*.bin` holds
Blastware's bytes.
**Second: swap the geophone** between a faulted base and a healthy one. Fault
follows the sensor → element or cable. Fault stays with the base → front-end
board. One afternoon, zero code, and it settles the one question the archive is
permanently blind to.
**Third: log a faulting unit for 72 h untouched.** Every recovery we have is
confounded by a possible field autozero. A shelf and a logger settles whether
the fault genuinely self-reverses.
**Fourth, free: re-cut the fleet label** — drop the spread gate, re-score
amplitude-only, screen the 11 unscreened thin-coverage units. Might reach 9–10
positives. Be honest about the gain: power against "older half carries 3x the
hazard" rises only 0.23 → 0.30.
**Highest-value item overall, and not an experiment: the RMA/repair records.**
Which unit went back, when, what was done (autozero vs geophone replaced vs
board), and the geophone serial fitted. "Same channel after a documented
geophone *replacement*" is component-level-negative in one observation.
---
### 8d. The non-motion test — Brian's "it doesn't cross zero" (2026-09-07)
Looking at BE12599's 2026-08-09 event, Brian noted it reports no ZC frequency
**because the trace never crosses zero**. That observation is the best detector
in this investigation, and it comes from physics rather than a threshold.
A geophone is a velocity sensor with no DC response, so its output over a record
must integrate to ~zero — the ground does not relocate. Real motion therefore
sits roughly half below zero. Anything electrical is one-sided.
mp = |mean| / peak ~0 for motion, ~1 for a fault
frac_neg = share of samples < 0
`scratch/nonmotion_scan.py`, all 6,577 waveforms, 19,731 channel-rows.
Restricted to peak >= 0.05 in/s (n = 12,068), the distribution is **bimodal
with an empty middle**:
| mp band | channel-events |
|---|---|
| 0.0–0.1 | 11,384 |
| 0.1–0.2 | 293 |
| **0.15–0.85 (dead zone)** | **131 = 1.09%** |
| 0.9–1.0 | 278 |
At `mp >= 0.8` with >=3 events it returns **exactly the five confirmed units** —
BE9558, BE11529, BE12599, BE13117, BE18438 — stable from 0.5 to 0.9. Two
detectors on entirely different principles agreeing on the unit list is the
strongest corroboration that list has.
**BE11007 is settled: NOT an offset.** It reaches mp 0.75–0.89, but with
`frac_neg = 0.99` at peaks of **7.4–9.4 in/s** — parked *negative* during a
near-full-scale blast. §4's guess was right. `mp` alone cannot separate a
pedestal from a large one-sided blast; pair it with a peak ceiling or with
sign-consistency across events.
⚠ **Not a rediscovery of the retracted v1 detector.** v1 scored only the
largest-peak axis and used the mean as a *baseline estimator* where the median
was required. Here the mean is the signal itself, per channel — that is what the
physics licenses.
**Correction to §8c.** That section says the spread gate is "blind to onsets by
construction." Too strong: of 87 BE18438|Vert events at mp >= 0.5 the gate
rejected **one** — the transitional record. It does not lose onsets
systematically; it loses the transition specifically.
### 8e. BE12599 — a connector, not a geophone (2026-09-07)
Waveform shapes across its August episode, measured rather than eyeballed:
| date | channel | shape |
|---|---|---|
| Aug 09 05:29 | Long | **unipolar +**, 0/2304 samples below zero, decay tau **26 ms** |
| Aug 09 05:35 | Long | unipolar +, 3 spikes at irregular gaps (744, 1032 ms), tau **38 ms** |
| Aug 14 05:00 | Long | single lobe, bipolar, tau **118 ms** |
| Aug 17–23 | Tran | **flat DC pedestal**, sd/level 0.015–0.020, 0 zero crossings |
**Unipolar impulses with an RC tail are not mechanical.** Fast rise, exponential
decay, one polarity, irregular timing — that is charge dumped into a
capacitively-coupled input and draining through the input resistance. The
progression 26 ms -> 118 ms -> never recovers, over 14 days, is a leakage path
worsening.
**And the fault moved channels** — Long on Aug 9/14, Tran on Aug 17–23, Long
again on Aug 21 (1.065 in/s) while Tran held its pedestal. Vert stayed clean
throughout. **A failing geophone element cannot hop channels. A connector can.**
That single fact explains what had been puzzling:
- **The sensor self-check keeps passing** (7.4/7.5/7.6 Hz, ratios 3.6–4.2, all
four channels Passed, on the very events where Long throws 0.5 in/s spikes).
The swing test drives the element; the element is fine. The fault is in the
wiring to it.
- **Why Instantel's autozero fixes only ~10%** — it cannot fix a connector.
- **Why onset "ramps" over minutes to hours** — contact resistance drifting.
All seven Aug 17–23 events are stamped **05:00:14**, the same second, and their
filename extensions run `8E → WE → KE → 8E → WE → KE → 8E` — the documented
3-day cycle for a fixed daily time. Clock-scheduled, not physically triggered:
the modem powers up, draws a surge, and a marginal connection responds.
**Field action: inspect and photograph the geophone connector BEFORE reseating
anything** — an intermittent contact clears the moment it is disturbed.
⚠ Scoped to BE12599. BE18438's onset was a smooth 7-minute ramp with no spikes,
which looks like a different failure mode wearing the same signature.
---
### ⚠ Serial prefixes — four of these units are BlastMates, not MiniMates
Corrected 2026-09-06, after Brian queried "BA10895?" against a report that
said BE10895. He was right. The BW filename encodes the serial **number
only** — `L895` -> 10895 — and every offset scanner synthesised the family
prefix as `"BE"`. Four of the 43 archive units are **BA** (BlastMate, the
MiniMate Plus's bigger sibling; same Series III, byte-identical data):
**BA9229, BA10060, BA10895, BA15957.**
Read off the file bodies, which carry the serial verbatim. No analysis
changed — grouping was always on the numeric part, and no unit number maps
to two serials — but every earlier reference to "BE10895" and the other
three is a label error and has been corrected throughout this document.
The same assumption was live in two production sites and is fixed
(`sfm/waveform_store.py`, `minimateplus/client.py`): the store would have
filed a BlastMate under a unit that does not exist, and the monitor-log
decoder lost the geo threshold along with the serial. See commit `9ceff65`.
---
## 9. Chronology
| date | event |
|---|---|
| 2026-08-25 | Reported as a *waveform decode bug* — traces with a DC offset. Investigation shows the offset is **real device data**; the decoder is correct. |
| 2026-08-25 | Brian relays his dad's description: a known hardware fault called an "offset"; usually sent to Instantel. |
| 2026-08-25 | First detection pass over the Terra-View DB: **2 of 21 units**, 274 events, 11 months. Flagged as vulnerable to survivorship bias — flooded events were routinely deleted. |
| 2026-08-25 | Condensation hypothesis proposed, then **killed by its own controls**. |
| 2026-08-25 | Parked pending the multi-year archive. |
| 2026-08-28 | DL2 archive pulled (33 GB, 546k files; 6.6 GB working set). |
| 2026-08-28 | Archive scan: **6 of 45 units**, 283 events, 15 episodes. Prior base rate **confirmed**, not overturned. |
| 2026-08-28 | Clipping ruled out; `m/p` established as the discriminator; BE11007 reclassified as probably a real blast. |
| 2026-08-28 | Calibration-timing correlation attempted and **rejected as confounded**. |
| 2026-08-28 | Instantel FAQs supplied: autozero procedure, the **2027–2069** window, the **>5 counts** threshold. Explains the ~10% re-zero success rate. |
| 2026-08-28 | Bimodality established; sensor check proven **blind** to offsets; `SUB 0x0E` identified as the best open lead. |
| 2026-08-28 | **v1 detector retracted.** Brian challenged the "come and go" finding against field experience. Two flaws found: dominant-axis-only scoring and mean-instead-of-median. Corrected detector shows persistent pedestals on **8 of 45 units**, and the gaps are service windows. |
| 2026-08-28 | **Detector v3 (Brian's method):** pre-trigger floor + pre/mid/end consistency. Healthy channels proven to sit at 0.000 +/-1 unit (94.5%), confirming no decoder zero-point bias. Final: **5 of 45 units (11%)**, threshold-insensitive. |
| 2026-09-04 | **Histogram corpus scanned** — 63,505 of 63,535 files, 43 units, 77.9M intervals (9.7x the waveform corpus). `scratch/offset_hist_scan.py`. |
| 2026-09-04 | Absolute-floor statistic **retired**: 66% of its discrimination is a day/site confound (other-channels-only AUC 0.746 vs 0.872). Zero-fraction shown **structurally impossible** — the device clamps every interval peak at >= 1 count. |
| 2026-09-04 | Site-quiet-gated cross-channel differential established: **BE18438 Vert, BE9558 Tran+Long**, threshold-insensitive over a 2.3x span. Finds only **2 of the 5** confirmed units — leakage into the histogram floor is bimodal (0.9 to 0.02), so a negative result carries almost no information. Per-channel attribution **not** established (channel-scramble p = 0.769). |
| 2026-09-04 | **BA10895 reclassified** from transient to a genuine Vert fault of a different subtype — 49.4% single-axis-dominant events, the highest in the fleet, 100% on Vert. The other six marginal units are clean. |
| 2026-09-04 | **Defect found in `offset_scan3.py`**: its `spread <= 0.02` gate discards 18.8% of rows with \|pre\| >= 0.025, concentrated on 41 negative unit-channels; 4 would be sustained positives without it. The fleet label is three-state, not two. |
| 2026-09-06 | **Four units relabelled BA, not BE** — BA9229, BA10060, BA10895, BA15957 are BlastMates. The BW filename carries only the serial number; the family prefix must be read from the file body. Fixed in the scanners and in two production sites. |
| 2026-09-06 | **Mechanism campaign — five hypotheses, all dead.** Thermal, ground-motion shock, handling/redeployment, accumulated duty, unit age, firmware and a mechanical element fault are each refuted or bounded. 7 nominally significant results against 5.2 expected by chance. |
| 2026-09-06 | **Onset is a RAMP of minutes-to-hours, not a step** — BE18438 Vert resolved to one-minute cadence, 50% of the excursion in 7 min, >=25 intermediates, ASCII-validated 75/75. Kills both a latched digital step AND slow component degradation. Surviving shape: a reversible two-time-constant settling process — a bias/leakage path charging a high-impedance node. |
| 2026-09-06 | **Polarity consistency RETRACTED** (a tautology of the spread gate; amplitude-only gives 12 of 53 unit-channels mixed) and the fleet **re-cut to 8–9 units, not 5**. "Persistent until serviced" weakened: 23 recoveries, median gap 6 days — though a field autozero cannot be excluded. |
| 2026-09-06 | The spread gate is **blind to onsets by construction** — it rejects a moving floor, which is what an onset is. It rejected the very record in which the ramp is visible. |
| 2026-09-07 | **The non-motion test** (Brian: "it doesn't cross zero"). `\|mean\|/peak` is bimodal with a 1.09% dead zone and returns exactly the 5 confirmed units from physics, not a threshold. Independent corroboration of the unit list. **BE11007 settled as NOT an offset** — a one-sided 9 in/s blast. |
| 2026-09-07 | **BE12599 is a connector fault, not a geophone fault.** Unipolar spikes with a 26→118 ms RC tail progressing to a flat pedestal, and the fault MOVES between Long and Tran while the sensor self-check passes on every event. An element cannot hop channels; a connector can. Inspect before reseating. |
-135
View File
@@ -1,135 +0,0 @@
# USBM RI8507 / OSMRE Blasting Compliance Curve — Reference
Reference for the **velocity-vs-frequency blasting compliance chart** Blastware
draws on its Event Report ("USBM RI8507 And OSMRE"), and how seismo-relay
reproduces it. Implemented in [`sfm/compliance.py`](../sfm/compliance.py); the
spectral (FFT) side lives in [`waveform_fft.py`](../waveform_fft.py).
Reverse-engineered 2026-09-14 against 7 BE12844 (MiniMate Plus) events, each
with a Blastware Event Report + FFT Report as ground truth. Curve values from
USBM RI8507 Appendix B and 30 CFR 816.67.
---
## What it is
Two closely-related sources for the same limit curve:
- **USBM RI8507** — Bureau of Mines *Report of Investigations 8507* (Siskind
et al., 1980), *"Structure Response and Damage Produced by Ground Vibration
From Surface Mine Blasting."* The curve is **Figure B-1**, Appendix B
("Alternative Blasting Level Criteria"), p.73–74.
- **OSMRE / OSM** — the Office of Surface Mining Reclamation and Enforcement
codified it as **30 CFR 816.67, Figure 1**. "CFR" = the U.S. Code of Federal
Regulations. Same curve, regulatory force.
The chart plots each geophone channel's significant vibration cycles as
`(frequency, peak velocity)` points against this limit. A point **below** the
line passes; **above** fails.
---
## The limit curve
A structure has a resonance band (~4–12 Hz for whole structures) where it is
most vulnerable, so the safe velocity is **lower** at those frequencies and
**higher** away from them. The curve captures this by alternating two kinds of
bound:
- **Constant-velocity** segments — a flat horizontal line at a fixed PPV.
- **Constant-displacement** segments — a fixed peak *displacement* `d`. For
simple harmonic motion, peak velocity `v = 2πf·d`, so on a velocity-vs-
frequency **log-log** plot this is a straight line of slope +1 (velocity rises
with frequency). This is why the low- and high-frequency bounds are sloped.
### Two lines — structure type
RI8507 gives two lines for two interior-wall constructions (Table 13, p.67):
| line | construction | plateau PPV |
|---|---|---|
| **Drywall** (solid) | modern gypsum wallboard | **0.75 in/s** |
| **Plaster** (dashed) | older plaster on wood lath | **0.50 in/s** |
Plaster-on-lath is more damage-prone, hence the lower limit. You apply **one**
line depending on the monitored structure.
### The four segments (Figure B-1, p.74)
Going low → high frequency, each line is:
1. **Ultimate low-frequency bound** — constant displacement **0.030 in**
(`v = 2πf·0.030`). Only relevant below ~4 Hz.
2. **Plateau** — constant velocity **0.75** (Drywall) / **0.50** (plaster) in/s.
3. **Rising diagonal** — constant displacement **0.008 in** (`v = 2πf·0.008`),
climbing from the plateau up to the high-frequency cap.
4. **High-frequency cap** — constant velocity **2.0 in/s** above ~40 Hz.
The segments are drawn **continuous**: each bound is used over the frequency
range where it is the binding (lowest) limit, and consecutive bounds meet where
they are equal — so there are no vertical steps. Transition frequencies come
straight from the values (`f = V / (2π·d)`):
| transition | formula | Drywall | Plaster |
|---|---|---|---|
| 0.030 in → plateau | `V_mid / (2π·0.030)` | 3.98 Hz | 2.65 Hz |
| plateau → 0.008 in | `V_mid / (2π·0.008)` | 14.92 Hz | 9.95 Hz |
| 0.008 in → 2.0 in/s | `2.0 / (2π·0.008)` | 39.79 Hz | 39.79 Hz |
Because both lines share the same **0.008 in** rising diagonal, above ~15 Hz
they lie on the *same* line (both reach 2.0 in/s at ~40 Hz) — RI8507's literal
construction merges them there. Blastware renders the dashed line as a separate
parallel diagonal, but that is cosmetic: above ~15 Hz both structure types carry
the identical limit, so compliance is unaffected.
> ⚠ RI8507's *Table 13* is a simpler two-range criterion with a **sharp
> discontinuity at 40 Hz** (flat plateau, then a jump to 2.0). Figure B-1 is the
> **smoothed** version that adds the 0.008 in transition — that is the one drawn
> on reports and implemented here.
---
## The compliance scatter (the points)
The cloud is **not** the FFT spectrum. It is a per-cycle, time-domain measure by
the **zero-crossing method** (`channel_compliance_points`):
- Split the channel's waveform at its zero crossings.
- Each half-cycle contributes one point: **frequency** `= 1 / (2 · half-period)`
(from the samples between the two crossings), **velocity** `= peak |amplitude|`
in that half-cycle.
This yields ~90–110 points per channel, and — by construction — each channel's
**highest** point equals that channel's PPV. Verified against Blastware: the
cloud shape, density, and ceiling all match.
### Why not the FFT?
A broadband blast spreads its energy across many FFT bins, so no single bin
reaches the time-domain peak — the FFT amplitudes come out ~10× below the
compliance-chart velocities. The compliance chart is a *per-cycle peak* view;
the **FFT** is a separate analysis (Blastware's *FFT Report*), reproduced by
[`waveform_fft.py`](../waveform_fft.py) and used for the dominant-frequency
readout and the #10 FFT view — not for this scatter.
---
## Implementation
- `sfm/compliance.py`
- `limit_at(freq, curve)` — the limit PPV at a frequency (`curve` = `"Drywall"`
or `"Plaster"`); curves are data in `_CURVES`, so more standards can be added.
- `channel_compliance_points(samples, sps)` — the zero-crossing scatter.
- `draw_compliance_chart(ax, channels, sps)` — matplotlib rendering (both
limit lines + per-channel scatter, Blastware's tick scales and channel
markers: Tran `+` red, Vert `×` green, Long `o` blue).
- Tests: `tests/test_compliance.py`.
---
## Sources
- USBM **RI8507** (Siskind, Stagg, Kopp, Dowding, 1980), Appendix B / Figure B-1,
p.73–74; Table 13, p.67. (`ref-stuff/usbm-ri8507-ground_vibration.pdf`.)
- **30 CFR 816.67**, "Use of explosives: Control of adverse effects," Figure 1 —
<https://www.ecfr.gov/current/title-30/chapter-VII/subchapter-K/part-816/section-816.67>
-579
View File
@@ -1,579 +0,0 @@
# Runbook — Recovering a wedged unit stuck in a call-home loop
**Incidents:** BE9558H at `166.246.130.1:9034`, 2026-05-17 (Method B) ·
BE12599 at `166.246.64.226:9034`, 2026-09-16 (Method A).
A field unit with a stuck-triggered geophone (or any hardware fault causing
constant event triggering) will record events back-to-back, and if Auto Call
Home is set to "After Event Recorded" the device will dial the office BW
ACH server in a tight loop. Combined with a Sierra Wireless modem in
bidirectional serial-TCP mode, this makes the unit effectively unreachable
from SFM — every TCP connection we open gets killed when the modem flips
from server-mode to client-mode to honor the device's next AT dial command.
This runbook describes how to break the loop and recover control.
---
## ⚠ Two cures for one disease — intercept first
Both incidents below are the **same failure**: a geophone offset crosses the
trigger level, the unit records back-to-back, ACH set to "after event
recorded" dials continuously, and the unit becomes unreachable because its
modem is in client mode almost all of the time.
There are two ways to get a Stop Monitoring command into it.
| | **A — intercept the call** (preferred) | **B — catch it between calls** (original) |
|---|---|---|
| Idea | Be the server it dials. Point the modem's Destination at our own ACH server and answer it. | Clear the Destination so it stops dialing, then race a Stop into the gap. |
| Needs inbound? | **No — the unit calls us** | Yes: working inbound TCP to the modem |
| Determinism | Deterministic — it dials every ~75 s, we only have to be listening | A race. BE9558H took ~7 h of attempts before one landed. |
| Tool | `bridges/ach_server.py --stop-monitoring` | `scripts/slow_drip.sh` |
| Proven on | BE12599, 2026-09-16 | BE9558H, 2026-05-17 |
**Method A is the standard procedure now.** The unit won't answer us because
it is on the phone — so stop dialing it and be the one it calls. It rings,
we pick up, take its data, and tell it to stop calling here.
Method B is kept because it is proven, and because A needs a listener the
modem can actually reach (public IP + forwarded port). When you have that,
don't race it — intercept it.
---
## Symptoms
- Terra-View / SFM `/device/info` either hangs or fails on `count_events()`.
- `/device/monitor/status` and `/device/rescue` return 502 (protocol timeout
waiting for POLL response) or 503 (TCP connect refused).
- ACEmanager serial log shows repeating
`Connect to IP: <BW_IP> Port: <BW_PORT>` → `Shutdown TCP socket` cycles
every 30-60 seconds.
- Spam-mode endpoints (`/device/stop_monitoring_spam`) report many
`sent_ok` but the device's monitoring state never changes.
- `slow_drip` reports `[Errno 32] Broken pipe` after sending the preamble
but before completing the drip loop.
If you see *all* of these, the unit is in this exact failure mode.
---
## Method A (preferred) — intercept the call
You need **ACEmanager access** and a host the modem can dial: public IP with
the listener's port forwarded to it.
### A1 — start the listener BEFORE touching the modem
```bash
cd /home/serversdown/seismo-relay
tmux new -s rescue
.venv/bin/python -u bridges/ach_server.py --port 12345 \
-o bridges/captures/<unit>-diag --stop-monitoring -v
```
⚠ **Listener first, always.** A Destination pointed at a dead port is the
worst state available — the device still dials, the modem still flips to
client mode, inbound stays blocked, and nothing gets delivered.
Do **not** add `--events-only` (it silently breaks dedup — see gotchas), and
do **not** add `--disable-ach` yet (see A4).
### A2 — point the modem at it
ACEmanager → **Serial → Port Configuration**:
| Field | Set to |
|---|---|
| **Destination Address** | the listener's public IP |
| **Destination Port** | the listener's port (e.g. `12345`) |
Apply. The modem auto-dials its Destination whenever serial data arrives
while the serial port is closed — so the unit's own retry cycle now lands on
you instead of nowhere.
### A3 — answer, and stop the bleeding
Within ~75 s you should see a call-in. `--stop-monitoring` fires SUB 0x97 at
step 1.5 — after the handshake, **before** the event walk — so the recording
halts at the earliest possible moment in the session. Confirm via
`rescue.json` in the session directory:
```json
{"peer": "166.246.64.226:60921", "stop_monitoring": "ok"}
```
That is the bleeding stopped. Everything after this is cleanup.
### A4 — drain the backlog, THEN disable ACH
⚠ **Order matters, and it is counter-intuitive.** Stopping monitoring also
removes your call-in trigger: ACH fires on "after event recorded", so with
recording stopped the unit has no reason to dial again. The backlog sitting
in its memory does **not** re-arm it.
So if the stored events are worth keeping — and on a fault unit they usually
are, they're the evidence — drain them across however many call-ins it takes
*before* you silence it. Only then add `--disable-ach` (or use
`scripts/rescue_device.sh <host> <port> --no-erase`).
If the unit has gone quiet and you still need it, cycling the modem produces
a call-in, and a unit with a scheduled daily call will dial at its configured
time regardless.
### A5 — restore the Destination, and confirm you did
Put `Destination Address` back to `0.0.0.0` (or the office Instantel ACH
server) once you are finished, and only stop the listener after that is done.
### A6 — do NOT re-enable ACH until the hardware fault is repaired
Otherwise the loop restarts the moment monitoring resumes and you run this
runbook again.
---
## Method B (fallback) — catch it between calls
The original 2026-05 procedure. Use when you cannot stand up a listener the
modem can reach. You need **ACEmanager access** to the unit's modem.
### Step 1: stop the modem's mode-flipping
In ACEmanager → **Serial → Port Configuration**:
| Field | Set to |
|---|---|
| **Destination Address** | clear (blank) |
| **Destination Port** | `0` |
Click **Apply**. This removes the modem's auto-dial-out target. The device's
AT dial commands now error back at the modem instead of triggering a
mode-flip, so the modem stays in TCP-server mode permanently and our inbound
TCP sessions stay alive.
*(Optional belt-and-suspenders: also add the BW server's port to
**Security → Port Filtering - Outbound** as a blocked port, with
Outbound Port Filtering Mode = Blocked Ports.)*
### Step 2: stop monitoring on the device (slow drip)
From the SFM host:
```bash
/home/serversdown/seismo-relay/scripts/slow_drip.sh <DEVICE_IP> <PORT>
```
Defaults are 120s duration with a drip every 3s. Watch the response:
- `duration_s ≈ 120` and `drips_sent ≈ 40` → session held the full duration ✓
- `bytes_received > 0` → device is responding ✓ (this is the success signal)
If `duration_s` is small or `send_error: "Broken pipe"`, Step 1 didn't take
hold — re-check ACEmanager, may need to reboot the modem after Apply.
### Step 3: confirm monitoring stopped
```bash
curl 'http://localhost:8200/device/monitor/status?host=<DEVICE_IP>&tcp_port=<PORT>&force=true'
# expect: {"is_monitoring": false, ...}
```
### Step 4: disable ACH at the device level + erase corrupted events
Either fire the rescue endpoint:
```bash
/home/serversdown/seismo-relay/scripts/rescue_device.sh <DEVICE_IP> <PORT>
```
Or do the two steps manually:
```bash
# Disable ACH in the device's compliance config
curl -X POST 'http://localhost:8200/device/call_home?host=<DEVICE_IP>&tcp_port=<PORT>' \
-H 'Content-Type: application/json' \
-d '{"auto_call_home_enabled": false}'
# Erase corrupted event chain
curl -X POST 'http://localhost:8200/device/events/erase?host=<DEVICE_IP>&tcp_port=<PORT>'
```
You can also do this via the SFM standalone UI → **Call Home** tab → set
`Enable Auto Call Home` to `Disabled` → **Write to Device**.
### Step 5: restore modem config (housekeeping)
Once the device-side ACH is disabled, restore the modem's Destination
Address and Port to the original values (e.g. `50.197.32.92` / `12345`) in
ACEmanager. The modem will resume normal bidirectional behavior, but the
unit won't issue any dial commands until ACH is explicitly re-enabled on
the device.
### Step 6: do NOT re-enable ACH on this unit until the underlying hardware
fault is repaired. If you do, the call-home loop starts again immediately
and you'll be running this runbook a second time.
---
## Why this works — the failure mode explained
The Sierra Wireless RV50/RV55 serial port operates in one of two TCP modes
at any moment:
- **Server mode** — listens on `Device Port` (e.g. 9034), bridges inbound
TCP to the device's serial port. This is what we need to interact with
the device.
- **Client mode** — when the device sends an AT dial command on its serial
TX line, the modem opens an outbound TCP to `Destination Address:Port`
and bridges that to serial.
A serial port in this configuration is **bidirectional**: the modem flips
between server and client modes on demand. When the device's firmware is
healthy and only dials occasionally, this works fine.
When the unit is constantly triggering events and ACH is set to "After
Event Recorded", the device sends an AT dial command every few seconds.
Each one causes the modem to:
1. Drop any active inbound TCP session
2. Flip to client mode
3. Attempt outbound TCP to `Destination Address:Port`
4. Hang for up to a minute waiting for it to succeed/fail
5. Drop back to server mode
**During the entire hang, no inbound TCP can establish.** Even between
hangs, the modem closes any existing inbound session before flipping. So
any tool that needs more than a few seconds of held TCP (e.g. POLL +
config read + write) gets repeatedly kicked off.
Clearing `Destination Address` removes step 3-4 from the cycle: the modem
has nowhere to dial, so it doesn't flip modes when it receives an AT dial
command. The serial port effectively becomes server-only, and inbound TCP
sessions can stay open as long as needed.
**This is a modem-layer issue, not a device firmware issue.** The device
is alive and responsive the whole time — confirmed in the BE9558H
recovery by 990 bytes of S3 responses received over a 120s slow-drip
session once the modem was no longer mode-flipping.
---
## Why simpler approaches don't work
| Approach | Why it fails |
|---|---|
| Standard `/device/info` | Triggers `count_events()` 1E/1F walk, takes 90s+ and hits corrupted event chain in this scenario |
| `/device/rescue` race loop | Gets 502 (protocol timeout) because the modem closes the TCP before the POLL handshake can complete |
| `/device/stop_monitoring_blind` (single frame) | Even if the bytes leave the wire, the device's protocol parser ignores write commands without a preceding POLL handshake (early-version bug, now fixed by including POLL preamble in blind sends) |
| `/device/stop_monitoring_spam` (sub-second cadence) | Each session is killed by the modem's mode-flip before the device can drain its UART RX buffer; high-rate spam also risks UART FIFO overrun on the device side |
| Outbound port firewall block alone | Stops the outbound TCP from succeeding, but doesn't stop the modem from *trying* and mode-flipping. Reduces but doesn't eliminate the contention. |
| Modem reboot | Temporary — as soon as the device starts triggering again, the loop resumes within seconds |
The combination of `slow_drip` + cleared `Destination Address` works because:
1. The modem stops mode-flipping → TCP session stays open for the full
drip duration
2. Slow drip rate → device's UART RX FIFO never overflows even if
firmware is busy with event recording
3. The drip is `SESSION_RESET + STOP_MONITORING` every 3s → many
independent chances for the parser to land one valid frame
4. Once one Stop Monitoring is parsed, event recording halts → firmware
has CPU to spare → subsequent operations are trivially easy
---
## Tooling reference
All endpoints live in `seismo-relay/sfm/server.py`. All scripts live in
`seismo-relay/scripts/` and default to SFM direct (`http://localhost:8200`),
overridable via `SFM_BASE_URL`.
### Endpoints added during BE9558H recovery
| Endpoint | Purpose |
|---|---|
| `GET /device/events/storage_range` | SUB 0x06 — first/last event keys, `is_empty` flag. ~2s, no event walk. |
| `GET /device/events/index` | SUB 0x08 — lifetime event counter (does NOT decrement on erase). ~2s. |
| `POST /device/events/erase` | Full erase sequence 0xA3 → 0x1C → 0x06 → 0xA2. |
| `POST /device/rescue` | Disable ACH + erase in one TCP session. Short timeouts for race-loop usage. |
| `POST /device/stop_monitoring_blind` | Fire-and-forget Stop with full POLL preamble (single attempt). |
| `POST /device/stop_monitoring_spam` | Server-side tight retry loop, sub-second cadence, duration-bounded. |
| `POST /device/stop_monitoring_slow_drip` | One held TCP session, slow trickle of stop frames. **The endpoint that saved BE9558H.** |
Also changed: default protocol recv timeout dropped from 30s → 10s in
`_build_client`. Added `connect_timeout` knob to same. Cleaned up
unhandled-exception path in `/device/monitor/status` so it returns 502
instead of 500 on protocol timeouts.
### Scripts
| Script | Purpose |
|---|---|
| `scripts/rescue_device.sh` | Race-loop wrapper around `/device/rescue` |
| `scripts/blind_stop.sh` | Race-loop wrapper around `/device/stop_monitoring_blind` |
| `scripts/spam_stop.sh` | Single-call burst hammer (`/device/stop_monitoring_spam`) |
| `scripts/slow_drip.sh` | Single-call held-session drip (`/device/stop_monitoring_slow_drip`) |
| `scripts/watch_unit.sh` | Passive periodic reachability check, logs to file |
---
## Incident log — BE9558H, 2026-05-16/17
What was wrong: Long-axis geophone developed an offset, constantly above
trigger threshold → constant event recording → after-event ACH set →
modem dialing office BW server (`50.197.32.92:12345`) every 30-60s.
Local event chain corrupted (`next_boundary 0x100EE exceeds uint16`).
Diagnostic path:
1. `/device/info` slow, choked on event walk
2. Built lightweight probe endpoints (`storage_range`, `index`) — useful
but didn't reach the wedged unit
3. Built `/device/rescue` with short timeouts — got 502 (POLL no response)
4. Built `/device/stop_monitoring_blind` — first version was a false
positive (no POLL preamble); fixed by including
`SESSION_RESET+POLL_PROBE+SESSION_RESET+POLL_DATA` in the dump
5. Verified blind stop works on bench unit
6. Built `/device/stop_monitoring_spam` — 420 successful sends over
5 min, zero behavior change on field unit
7. Inspected ACEmanager logs → saw outbound dial-out attempts every ~30s,
confirmed device was not fully locked up
8. Added outbound port-12345 firewall block → outbound attempts now fail
instantly but contention persisted
9. Built `/device/stop_monitoring_slow_drip` — session died at 3s with
broken pipe (modem closing on us)
10. Looked at full ACEmanager Port Configuration → **found
`Destination Address: 50.197.32.92` configured**, realized every AT
dial command was triggering a modem mode-flip that killed our inbound
11. Cleared Destination Address + Port → slow_drip held 120s, device
responded with 990 bytes, 39 stop commands acked
12. Disabled ACH at device level via `/device/call_home`, erased events
Final state: device IDLE, memory 958.1 / 960 KB free, ACH disabled at
device level, modem destination cleared (to be restored after physical
service).
Total time from "i was wondering if its possible to" first attempt to
recovery: ~7 hours of intermittent debugging across one evening.
---
# Second incident — BE12599, 2026-09-16/17
**Unit:** BE12599 at `166.246.64.226:9034`, RV50, job *I-80 North Fork Bridge
— Abut 1 West* (Fay Company). Same job as BE9558H, which is a coincidence.
**Fault:** the connector fault documented in `docs/offset_investigation.md`
§8e progressed until the Tran pedestal reached **0.400 in/s** — its trigger
level. Constant triggering → constant recording → ACH "after event recorded"
→ continuous dialing. Same disease as BE9558H.
**Same disease, inverted cure.** Method B's Step 1 *did* work — clearing the
Destination stopped the dial-outs, confirmed in the ALEOS log. It was Step 2
that didn't land, and rather than keep racing we turned the rescue around:
gave the unit a different server to call, and answered it.
Total time ≈ 5 h, of which ~90 min went to two red herrings documented below.
Much of the rest was rediscovering the May procedure, which is why the
"two cures" table now sits at the top of this file.
---
## Turn on ALEOS_SERIAL debug FIRST
This is the single highest-value diagnostic and it should be step zero on any
future incident. ACEmanager → **Admin → Log → ALEOS_SERIAL log level →
DEBUG**, then view the serial log.
It is the only thing that tells you what the *device* is actually saying.
Everything before we did this was guesswork.
## What the log showed — the unit is on the phone
Every ~75 seconds, verbatim:
```
ALEOS_SERIAL_HIF: 29 byte(s) in buffer: 'ATQ1^MATE0^MATS0=2^M^MRADIO RING^M'
ALEOS_SERIAL_HMC: TCP recvhost fd 65535 len 29 state TCPMode::kClosed
ALEOS_SERIAL_HMC: tcpmode trying to send to invalid socket
ALEOS_SERIAL_HMC: Connect to IP: 0.0.0.0 Port 0
ALEOS_SERIAL_HMC: Initialize Auto answer on port 9034
ALEOS_SERIAL_HMC: Cannot connect to 0.0.0.0
```
Read that carefully:
- `ATQ1` (quiet) / `ATE0` (echo off) / `ATS0=2` (auto-answer after 2 rings).
**There is no `ATD`.** The device is not dialing — it is trying to
*configure* its modem.
- The modem's serial port is in TCP data mode, so it never interprets these
as AT commands. It treats them as payload and tries to ship them to a TCP
socket that does not exist.
- The device therefore never receives `OK`, never progresses, and **retries
the identical 29 bytes forever**.
**While it is in this state it is busy placing a call, not listening for
us.** This is almost certainly what BE9558H was doing too — we simply never
turned on ALEOS_SERIAL debug in May to look. It is not a different disease;
it is the same one, seen properly for the first time.
It is also the argument for Method A in one picture: the unit is mid-dial
every ~75 s, and our inbound Stop has to thread the gaps between those
attempts. Give it somewhere to dial and the problem inverts into a
deterministic one.
### Why `slow_drip` lied
`slow_drip` returned the *success* signature except for the one field that
mattered:
```json
{"duration_s":120.0,"drips_sent":38,"bytes_sent":920,
"bytes_received":0,"send_error":null}
```
Full duration, no broken pipe — but zero bytes back. Cause is in the log
above: each 75 s cycle re-runs `Initialize Auto answer on port 9034`, which
orphans the held session (`data in for unknown reason 3 removing from
select`, `OnMsg recv error: 107 - Transport endpoint is not connected`). Our
local TCP stayed open so `sendall` never raised — but the modem stopped
bridging after the first re-init, so every drip after that went into a socket
nobody was reading.
⚠ **`send_error: null` + full duration is NOT success. Only
`bytes_received > 0` is success.**
⚠ **In fairness to slow_drip: it got exactly one attempt here**, run ~90 s
after a modem reboot, with a dead session visible in the log at 20:19:17 in
that same window. BE9558H took hours of attempts before one landed. Method B
was not ruled out on BE12599 so much as abandoned in favour of something that
doesn't need luck.
---
## ⚠ Two red herrings that cost ~90 minutes
### 1. The trusted-IP whitelist (this was the real reason inbound never worked)
The RV50s run with **Security → Trusted IPs (Friends List) enabled**. A
source IP that is not on the list is dropped **silently** — inbound presents
as `Connection error: timed out`, never a refusal.
Brian's dev-box public IP is **dynamic** and had changed, so `tmi-dev` was no
longer whitelisted. Every inbound attempt failed identically across four
different modem and device states, which looked exactly like the BE9558H
mode-flipping symptom and sent us chasing modem configuration for over an
hour.
**Check this before diagnosing anything else.** Note that SFM in Docker
egresses via the *host's public IP*, not its LAN IP.
### 2. A 502 from SFM does not mean TCP connected
`sfm/server.py` raises **502 for both** failure classes:
```python
raise HTTPException(status_code=502, detail=f"Protocol error: {exc}")
raise HTTPException(status_code=502, detail=f"Connection error: {exc}")
```
We read an early 502 as "TCP connected, modem bridged, device mute" and built
a whole theory on it. It was almost certainly a connect timeout.
**Always read the `detail` string** — "connect failed" and "device didn't
answer" are completely different problems and the status code will not
separate them.
---
## What actually worked — invert the direction
The key observation is in the log above:
> `TCP recvhost ... state TCPMode::kClosed` → `Connect to IP: 0.0.0.0 Port 0`
**The modem auto-dials its Destination whenever serial data arrives while
closed.** So instead of fighting for inbound, give it somewhere to dial:
point `Destination Address` at our own `ach_server` and the device's own
75-second attempts become **device-initiated sessions the modem bridges
correctly**. No race, no contention, worst case a 75-second wait.
### Procedure
1. **Run the rescue server** on a host the modem can reach (public IP +
forwarded port):
```bash
cd /home/serversdown/seismo-relay
.venv/bin/python -u bridges/ach_server.py --port 12345 \
-o bridges/captures/<unit>-diag --stop-monitoring -v
```
2. **Point the modem at it** — ACEmanager → Serial → Port Configuration →
`Destination Address` = your public IP, `Destination Port` = 12345.
3. **Wait for the call-in.** `--stop-monitoring` fires SUB 0x97 at step 1.5,
after the handshake and *before* the event walk. Confirm via
`rescue.json` in the session directory:
```json
{"peer": "166.246.64.226:60921", "stop_monitoring": "ok"}
```
4. **Restore the modem's Destination** once you are done, then finish the
device side (disable ACH, erase) through whichever channel works.
On BE12599 the first call-in landed at 20:58:11 and reported
`stop_monitoring: ok`; a second at 20:58:20 confirmed it. `is_monitoring:
false` was still true **6½ hours later** — the fix is durable.
---
## Hard-won gotchas (do not re-derive)
- **Never leave the Destination pointed at a host with nothing listening.**
That is the worst state available: the device still dials, the modem still
flips, inbound stays blocked, and nothing is delivered. An 8-minute gap
with the listener down produced a spurious inbound timeout that cost
another round of misdiagnosis.
- **Stopping monitoring removes your call-in channel.** ACH is "after event
recorded"; no new events means no new dials. The backlog sitting in memory
does *not* re-arm it. After a successful stop the unit goes quiet and you
need the modem cycled (works — produced a call-in), the scheduled daily call
(BE12599 calls at **05:00:14 device-local**, per §8e), or working inbound.
**Plan the order before you fire the stop.**
- **`--events-only` silently breaks dedup.** It skips the device-info step,
so the serial is never read; `ach_state.json` then keys on
`peer:ephemeral_port`, which is unique per connection. Every session looks
like a new unit, starts from key 0, and re-downloads the same event. Four
sessions on BE12599 downloaded the identical event four times and made zero
progress on the backlog. Events also file as `serial=UNKNOWN` with a
`M000…` BW filename (serial_numeric 0) instead of `N599…`.
**Do not use `--events-only` when you intend to download anything.**
- **`/device/events/index` reported `lifetime_count: 0`** on a unit with years
of history. Suspected decode bug in the SUB 0x08 field offset — do not
trust that number. The 88-byte payload is preserved in the `raw_hex` field
if someone wants to chase it.
- **Memory used cross-checks the event keys exactly:**
`last_key − buffer_start = memory_total − memory_free`. On BE12599:
`0x011230ec − 0x01110000 = 78,060` and `983,028 − 904,968 = 78,060`.
Useful sanity check that you are reading the keys right.
---
## Final state (2026-09-17 ~01:30 local)
- `is_monitoring: false`, held 6½ hours
- Battery 6.76 V
- Memory 78,060 / 983,028 bytes used (8%)
- `first_key 01121728`, `last_key 011230ec` — ~6.6 KB of addressable event
chain, roughly 3 events
- ACH still **enabled** — to be disabled after the backlog is preserved
- Modem Destination still pointed at tmi-dev — to be restored
- ⚠ **Do not re-enable ACH until the connector is serviced.** Tran is still
sitting at 0.400 and the loop restarts the moment monitoring resumes.
-150
View File
@@ -1,150 +0,0 @@
# SFM — where it actually stands as a tool
**Status as of 2026-09-20 (v0.31.0).** This is the honest assessment, not the
roadmap — `README.md § Roadmap` covers where it is *going*. Expect this file to
go stale; re-date it when you revise it.
---
## The framing
SFM is **three different things wearing one name**, at three very different
levels of maturity:
| | what it is | maturity |
|---|---|---|
| **The codec library** | `minimateplus/`, `micromate/` — bytes in, `Event` out | **Production.** Verified per-sample at scale. |
| **SDM — the data side** | the DB, waveform store, `/db/*`, ingest | **Production.** Terra-View depends on it daily. |
| **SFM — the device side** | `/device/*`, live connections to units | **Emergency-grade.** Works, but manual, unauthenticated, and thinly tested. |
| **The lab** | `seismo_lab.py`, `scratch/`, the Inspector | **Research artifacts.** Useful, not products. |
Brian's own description — *"right now it's an emergency tool and a research
project"* — is accurate, and it applies specifically to the **device side**.
The data side is not an emergency tool; it has been carrying production for
months.
Most confusion about "is SFM reliable?" comes from answering for the wrong
tier.
---
## 1. What you can rely on
### Production-grade — trust it
- **Series-3 decode.** 14,338 / 14,338 files decode per-sample exact against
preserved Blastware ASCII exports, 45 units, files back to 2018.
- **Series-4 (Thor) decode.** 1,057,536 / 1,057,536 geo samples exact against
Thor's own CSV exports; production IDFW 575/575 with zero truncations.
- **Histogram decode.** 1,211 / 1,211 production histograms exact, including
842,442 per-interval frequency comparisons with zero mismatches.
- **The ingest path.** `/db/import/blastware_file` and `/db/import/idf_file`
fed by the watchers — this is how prod actually gets its data, and it has
been running unattended for months.
- **`/db/*` read API.** Always-on, consumed by Terra-View for every fleet
listing, event detail and report.
- **The waveform store** — `.h5` + `.sfm.json` sidecars + retained raw
binaries, with operator review state preserved across regeneration.
- **`bridges/ach_server.py`** — speaks the full BW protocol to calling units.
Proven in the field, including as a rescue tool (see the runbook).
### Emergency-grade — works, but you are the error handling
- **`/device/*` live endpoints.** They do what they say. But they are
synchronous, unauthenticated, and a single cellular download can exceed the
60 s timeouts that sit in front of them.
- **The rescue ladder** (`rescue`, `stop_monitoring_*`, `events/erase`).
Each has worked in a real incident — but each has been used a handful of
times, by one person, with the runbook open.
- **The standalone webapp.** Perfectly usable, and as of v0.31.0 the cheap
probes and rescue actions are reachable without curl. No auth of any kind.
### Research artifacts — useful, not products
- **`seismo_lab.py`** — 2,789 lines of Tkinter (Bridge / Analyzer / Query DB /
Inspector). Desktop-only, single-user, no tests.
- **`scratch/`** — the verification harnesses (`verify_against_ascii.py`,
`verify_thor_against_csv.py`) and the offset detector (`offset_scan3.py`).
These produced the numbers the production claims rest on, so they matter —
but they are analysis scripts, not maintained code.
- **`docs/offset_investigation.md`** — an open investigation, not a feature.
---
## 2. What to use when
| you want to… | use | notes |
|---|---|---|
| Know if a unit is monitoring / its battery / memory | `GET /device/monitor/status?force=true` | ~2 s |
| Know whether ACH is on | `GET /device/call_home` | ~2 s. **Not** `/device/events`. |
| See how full a unit's buffer is | `GET /device/events/storage_range` | ~2 s, no chain walk |
| Stop a runaway unit | Diagnostics tab → Stop Monitoring | see the runbook first |
| Reach a unit that will not answer | **point its modem at an `ach_server` and answer its call** | runbook Method A — do not race it |
| List a unit's stored events | Events tab → Load events | **slow**, and broken past 64 KB (below) |
| Get event data into the DB | the watcher → `/db/import/*` path | not the live walk |
The single most useful habit: **the cheap probes are cheap and the event walk
is not.** Reaching for `/device/events` to answer a yes/no question about a
unit is the mistake that motivated the v0.31.0 webapp changes.
---
## 3. Known issues
| issue | impact | status |
|---|---|---|
| **5A walk dies once a unit's buffer crosses 64 KB** | `/device/events` 500s; event body never downloads | Known, documented in `CLAUDE.md`. Needs a BW capture of a spanning event to fix properly. |
| **No auth on SFM at all** | 21 `/device/*` endpoints, including destructive ones, open to anything that reaches the port | Design agreed (Terra-View as authenticated jump host); not built. |
| **Swagger try-it-out is live on destructive endpoints** | `POST /device/events/erase` is one click away at `:8200/docs` | Partially mitigated: the webapp's erase now requires typing the serial. `/docs` itself is unguarded. |
| **`SUB 0x08` lifetime counter reads 0** | `/device/events/index` returns a meaningless number | Suspected field-offset bug. Surfaced in the UI as "unreliable". |
| **Long device operations are synchronous** | 60 s timeouts in `routers/sfm.py` and the reverse proxy; a full download exceeds both | Known design constraint. Must be POST-starts-job / GET-polls before any remote lab. |
| **`backfill_sidecars.py --force` silently inserts DB rows** | store files with no DB row get one; the dry-run does not report the count | Known. Avoid `--force` — `TOOL_VERSION` gates regeneration anyway. |
| **14 sensitive-range files show an exact 8× discrepancy** | 10.0 / 1.25 — a units problem, not a decode problem | Open, not blocking. |
| **16 failing tests on `dev`** | 15 need gitignored fixture bundles; 1 is real (`sc["peak_values"]["transverse"]` returns `None` where `0.0` is expected) | The real one shipped in v0.31.0. |
---
## 4. What stands between this and a real tool
Roughly in dependency order — each unblocks the ones below it.
**1. Authentication.** Everything else is gated on this. SFM has none, and
the modem IP whitelist gives zero protection because SFM *is* the whitelisted
origin. The agreed design delegates rather than builds: Terra-View becomes the
authenticated jump host (`/api/sfm/*` already inherits deny-by-default operator
auth), and the `8200:8200` publish is dropped so Terra-View is the only door.
**2. Async long operations.** POST starts a job, GET polls. Retrofitting this
after building a remote lab on top of synchronous endpoints would be far worse
than designing for it now.
**3. Confirm-guards on the remaining destructive endpoints.** Auth answers
*who*, not *did you mean it*. The webapp's erase is guarded; the other seven
destructive POSTs and `/docs` are not.
**4. The 5A page-boundary fix.** Until this lands, live event download is
unreliable on exactly the units most likely to need attention — the ones that
have been recording heavily. Wants a Blastware capture of an event spanning a
page boundary before the chunk-addressing half is trustworthy.
**5. A live Thor / Micromate client.** The device side is MiniMate-only.
Series-4 units can only be read from forwarded files, so half the fleet has no
live path at all.
**6. Test coverage that runs from a clean checkout.** 15 of 16 current
failures are missing fixture bundles. A test suite that cannot go green on a
fresh clone cannot gate anything.
**7. The SDM rename.** Cosmetic relative to the above, but the longer `sfm/`
holds the data-side code the more the tiers blur. ~30–50 files here, ~10–15 in
Terra-View, plus a Docker volume migration. Do it when the codebase is quiet.
---
## The short version
The **data side is a real tool already**. The **device side is a set of sharp
instruments** that work in the hands of the person who wrote them, with the
runbook open. The gap between those two states is mostly **auth, async, and
guardrails** — not protocol work. The protocol is the part that is actually
finished.
@@ -1,628 +0,0 @@
# Waveform-shape FT detection — Phase A (seismo-relay) Implementation Plan
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** Compute per-event waveform-shape metrics (crest factor + points-near-peak) in SFM and store them as `events` columns, populated at ingest and by a backfill script, so Terra-View can read them from `/db/events`.
**Architecture:** A pure DSP module (`sfm/shape_metrics.py`) turns decoded `.h5` samples into shape metrics. New nullable `events.shape_*` columns are added via the existing `_migrate` ADD COLUMN loop. The three `WaveformStore.save*` paths compute shape from the just-written `.h5` and hand it to `insert_events`; a backfill script does the same over existing events. Mirrors exactly how per-channel ZC frequency was added.
**Tech Stack:** Python 3.10, numpy, h5py, sqlite3 (raw), pytest. seismo-relay venv: `/home/serversdown/seismo-relay/.venv/bin/python3`.
## Global Constraints
- Metrics are read from the `.h5` `samples/{Tran,Vert,Long}` float32 arrays (physical in/s). The measured channel is the max-|peak| geophone channel.
- All new columns are nullable; histogram records and events without usable samples store NULL (Terra-View falls back to cheap signals). Legacy rows stay valid.
- Crest factor = `max(|x|) / rms(x)`; near-peak count = number of samples with `|x| ≥ 0.5·peak`. Threshold `0.5` is a module constant so calibration can tune it.
- No manual migration: columns are added in `SeismoDb._migrate`, run at `SeismoDb()` construction.
- `/db/events` needs no change — it returns all columns via `SELECT *` (verify with a test).
- Run tests with `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest`.
---
### Task 1: Shape DSP module
**Files:**
- Create: `sfm/shape_metrics.py`
- Test: `tests/test_shape_metrics.py`
**Interfaces:**
- Produces:
- `channel_shape(x) -> dict | None` — `{"crest_factor": float, "near_peak_count": int, "sample_count": int}` or None for unusable input (size < 2, flat, all-zero).
- `shape_from_samples(chans: dict[str, ArrayLike]) -> dict | None` — picks the max-peak geophone channel; returns `{"crest_factor","near_peak_count","sample_count","axis"}` or None.
- `shape_from_h5(path) -> dict | None` — reads `samples/{Tran,Vert,Long}` and delegates to `shape_from_samples`; None on any read error.
- Constant `NEAR_PEAK_FRACTION = 0.5`.
- [ ] **Step 1: Write the failing test**
```python
# tests/test_shape_metrics.py
import numpy as np
from sfm.shape_metrics import channel_shape, shape_from_samples
def test_needle_spike_high_crest_few_near_peak():
x = np.zeros(1024); x[500] = 1.0 # one isolated spike
s = channel_shape(x)
assert s["sample_count"] == 1024
assert s["crest_factor"] > 15 # peak towers over rms
assert s["near_peak_count"] <= 3 # almost nothing near the peak
def test_ringing_low_crest_many_near_peak():
t = np.arange(1024)
x = np.sin(2*np.pi*t/32) * np.exp(-t/4000) # decaying oscillation
s = channel_shape(x)
assert s["crest_factor"] < 6
assert s["near_peak_count"] > 30 # many samples near the peak
def test_channel_shape_none_for_unusable():
assert channel_shape(np.zeros(1024)) is None # flat / all-zero
assert channel_shape(np.array([1.0])) is None # too short
def test_shape_from_samples_picks_max_peak_axis():
chans = {"Tran": np.zeros(1024), "Vert": np.zeros(1024), "Long": np.zeros(1024)}
chans["Long"][10] = 0.5
chans["Vert"] = np.sin(np.arange(1024)/5) * 0.01
s = shape_from_samples(chans)
assert s["axis"] == "Long" # Long has the biggest peak
assert s["near_peak_count"] <= 3
def test_shape_from_samples_none_when_no_geo():
assert shape_from_samples({"MicL": np.ones(1024)}) is None
```
- [ ] **Step 2: Run test to verify it fails**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_shape_metrics.py -q`
Expected: FAIL — `ModuleNotFoundError: sfm.shape_metrics`.
- [ ] **Step 3: Write minimal implementation**
```python
# sfm/shape_metrics.py
"""Waveform-shape metrics for false-trigger detection.
A false trigger is an isolated impulse (quiet → spike → quiet); a real event
rings for many cycles. Two numbers separate them: crest factor (how far the
peak stands above the typical sample) and how many samples sit near the peak.
"""
from __future__ import annotations
import numpy as np
_GEO_CHANNELS = ("Tran", "Vert", "Long")
NEAR_PEAK_FRACTION = 0.5 # a sample "near the peak" is >= this * peak amplitude
def channel_shape(x) -> dict | None:
x = np.asarray(x, dtype=float)
if x.size < 2:
return None
peak = float(np.max(np.abs(x)))
if peak <= 0:
return None
rms = float(np.sqrt(np.mean(x ** 2)))
if rms <= 0:
return None
near = int(np.sum(np.abs(x) >= NEAR_PEAK_FRACTION * peak))
return {"crest_factor": peak / rms, "near_peak_count": near,
"sample_count": int(x.size)}
def shape_from_samples(chans: dict) -> dict | None:
best_axis, best_peak, best_x = None, -1.0, None
for ax in _GEO_CHANNELS:
x = chans.get(ax)
if x is None:
continue
x = np.asarray(x, dtype=float)
if x.size < 2:
continue
p = float(np.max(np.abs(x)))
if p > best_peak:
best_axis, best_peak, best_x = ax, p, x
if best_axis is None:
return None
s = channel_shape(best_x)
if s is None:
return None
s["axis"] = best_axis
return s
def shape_from_h5(path) -> dict | None:
import h5py
try:
with h5py.File(path, "r") as f:
chans = {ax: f[f"samples/{ax}"][:] for ax in _GEO_CHANNELS
if f"samples/{ax}" in f}
except Exception:
return None
return shape_from_samples(chans)
```
- [ ] **Step 4: Run test to verify it passes**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_shape_metrics.py -q`
Expected: PASS (5 tests).
- [ ] **Step 5: Commit**
```bash
git add sfm/shape_metrics.py tests/test_shape_metrics.py
git commit -m "feat(shape): crest-factor + points-near-peak waveform metrics"
```
---
### Task 2: shape_from_h5 round-trips a real .h5
**Files:**
- Test: `tests/test_shape_metrics_h5.py`
**Interfaces:**
- Consumes: `sfm.shape_metrics.shape_from_h5`; `h5py`.
- [ ] **Step 1: Write the failing test** (writes a tiny .h5 the same shape SFM writes, then reads it back)
```python
# tests/test_shape_metrics_h5.py
import numpy as np, h5py
from sfm.shape_metrics import shape_from_h5
def _write_h5(path, chans):
with h5py.File(path, "w") as f:
g = f.create_group("samples")
for k, v in chans.items():
g.create_dataset(k, data=np.asarray(v, dtype="float32"))
def test_shape_from_h5_reads_dominant_axis(tmp_path):
p = tmp_path / "ev.h5"
long = np.zeros(1024, dtype="float32"); long[100] = 0.48
_write_h5(p, {"Tran": np.zeros(1024), "Vert": np.zeros(1024), "Long": long,
"MicL": np.ones(1024)})
s = shape_from_h5(str(p))
assert s["axis"] == "Long" and s["near_peak_count"] <= 3
def test_shape_from_h5_none_on_missing_or_degenerate(tmp_path):
assert shape_from_h5(str(tmp_path / "nope.h5")) is None
p = tmp_path / "degen.h5"
_write_h5(p, {"Tran": np.zeros(1), "Vert": np.zeros(1), "Long": np.zeros(1)})
assert shape_from_h5(str(p)) is None
```
- [ ] **Step 2: Run to verify it fails**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_shape_metrics_h5.py -q`
Expected: FAIL (assertion or, if Task 1 incomplete, import error).
- [ ] **Step 3: Implementation** — none needed; `shape_from_h5` already exists from Task 1. If a test fails, fix `shape_from_h5` (not the test).
- [ ] **Step 4: Run to verify it passes**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_shape_metrics_h5.py -q`
Expected: PASS (2 tests).
- [ ] **Step 5: Commit**
```bash
git add tests/test_shape_metrics_h5.py
git commit -m "test(shape): shape_from_h5 round-trips a real .h5"
```
---
### Task 3: Add shape columns to the events schema + migration
**Files:**
- Modify: `sfm/database.py` — `_SCHEMA` CREATE TABLE `events` (after `mic_zc_above_range`); `_migrate` ADD COLUMN loop (the tuple around line 205-218).
- Test: `tests/test_shape_columns.py`
**Interfaces:**
- Produces: `events` columns `shape_crest_factor REAL`, `shape_near_peak_count INTEGER`, `shape_sample_count INTEGER`, `shape_axis TEXT`.
- [ ] **Step 1: Write the failing test**
```python
# tests/test_shape_columns.py
import sqlite3
from sfm.database import SeismoDb
_SHAPE_COLS = {"shape_crest_factor", "shape_near_peak_count",
"shape_sample_count", "shape_axis"}
def _cols(db):
with sqlite3.connect(db.db_path) as c:
return {r[1] for r in c.execute("PRAGMA table_info(events)")}
def test_fresh_db_has_shape_columns(tmp_path):
db = SeismoDb(tmp_path / "s.db")
assert _SHAPE_COLS <= _cols(db)
def test_existing_db_migrates_shape_columns(tmp_path):
p = tmp_path / "s.db"
db = SeismoDb(p)
with sqlite3.connect(p) as c: # simulate an older DB missing the columns
for col in _SHAPE_COLS:
c.execute(f"ALTER TABLE events DROP COLUMN {col}")
assert not (_SHAPE_COLS <= _cols(SeismoDb(p))) # sanity: dropped
SeismoDb(p) # re-open triggers _migrate
assert _SHAPE_COLS <= _cols(SeismoDb(p))
```
> Note: sqlite `DROP COLUMN` needs sqlite ≥ 3.35 (bundled py3.10 has it). If the runner's sqlite lacks it, replace the "simulate older DB" block with building a table without the columns; keep the assertion that re-open adds them.
- [ ] **Step 2: Run to verify it fails**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_shape_columns.py -q`
Expected: FAIL — columns absent.
- [ ] **Step 3: Implementation**
In `_SCHEMA`, after the `mic_zc_above_range INTEGER,` line in the `events` CREATE TABLE, add:
```
shape_crest_factor REAL, -- peak / rms of the triggering channel
shape_near_peak_count INTEGER, -- samples >= 0.5 * peak (FT: few; real: many)
shape_sample_count INTEGER, -- total samples (to normalize near_peak_count)
shape_axis TEXT, -- geophone channel measured ("Tran"/"Vert"/"Long")
```
In `_migrate`, extend the ADD COLUMN tuple (the `for col, ddl in (...)` list) with:
```python
("shape_crest_factor", "REAL"),
("shape_near_peak_count", "INTEGER"),
("shape_sample_count", "INTEGER"),
("shape_axis", "TEXT"),
```
- [ ] **Step 4: Run to verify it passes**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_shape_columns.py -q`
Expected: PASS.
- [ ] **Step 5: Commit**
```bash
git add sfm/database.py tests/test_shape_columns.py
git commit -m "feat(db): shape_* columns on events (+ auto-migrate)"
```
---
### Task 4: insert_events persists shape from the waveform record
**Files:**
- Modify: `sfm/database.py` — `insert_events` INSERT (column list + placeholders + values) and the UPSERT `UPDATE` block.
- Test: `tests/test_insert_events_shape.py`
**Interfaces:**
- Consumes: a `waveform_records` rec dict that may carry `shape_crest_factor`, `shape_near_peak_count`, `shape_sample_count`, `shape_axis`.
- Produces: those four values stored on the row; refreshed on UPSERT.
- [ ] **Step 1: Write the failing test**
```python
# tests/test_insert_events_shape.py
from sfm.database import SeismoDb
from tests.helpers_events import make_event # existing helper used by other insert tests
def test_insert_stores_shape_from_record(tmp_path):
db = SeismoDb(tmp_path / "s.db")
ev = make_event(serial="BE1", key="0111abcd")
rec = {ev._waveform_key.hex(): {
"filename": "F.CE0W", "filesize": 10,
"shape_crest_factor": 34.0, "shape_near_peak_count": 3,
"shape_sample_count": 1024, "shape_axis": "Long"}}
db.insert_events([ev], serial="BE1", waveform_records=rec)
row = db.query_events(serial="BE1")[0]
assert row["shape_crest_factor"] == 34.0
assert row["shape_near_peak_count"] == 3
assert row["shape_axis"] == "Long"
```
> If `tests/helpers_events.make_event` doesn't exist, build the `Event` inline the way `tests/test_zc_freq_columns.py` does (copy its event-construction helper). Keep the assertion identical.
- [ ] **Step 2: Run to verify it fails**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_insert_events_shape.py -q`
Expected: FAIL — `KeyError`/`sqlite3.OperationalError` (columns not in INSERT) or values are NULL.
- [ ] **Step 3: Implementation**
In `insert_events` INSERT: add `shape_crest_factor, shape_near_peak_count, shape_sample_count, shape_axis` to the column list, add four `?` placeholders, and add these to the VALUES tuple (after the `mic_zc_above_range` value):
```python
rec.get("shape_crest_factor"),
rec.get("shape_near_peak_count"),
rec.get("shape_sample_count"),
rec.get("shape_axis"),
```
In the UPSERT `UPDATE ... SET`: add
```sql
shape_crest_factor = COALESCE(?, shape_crest_factor),
shape_near_peak_count = COALESCE(?, shape_near_peak_count),
shape_sample_count = COALESCE(?, shape_sample_count),
shape_axis = COALESCE(?, shape_axis),
```
and the matching params (before `serial, ts`):
```python
rec.get("shape_crest_factor") if rec else None,
rec.get("shape_near_peak_count") if rec else None,
rec.get("shape_sample_count") if rec else None,
rec.get("shape_axis") if rec else None,
```
(`COALESCE` on UPSERT so a re-import that lacks samples doesn't wipe a previously-computed shape.)
- [ ] **Step 4: Run to verify it passes**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_insert_events_shape.py -q`
Expected: PASS.
- [ ] **Step 5: Commit**
```bash
git add sfm/database.py tests/test_insert_events_shape.py
git commit -m "feat(db): insert_events persists shape_* from waveform record"
```
---
### Task 5: Populate shape at ingest (the three save paths)
**Files:**
- Modify: `sfm/waveform_store.py` — in `save`, `save_imported_bw`, `save_imported_idf`, after the `.h5` is written, add its shape to the returned `rec` dict.
- Test: `tests/test_save_shape.py`
**Interfaces:**
- Consumes: `sfm.shape_metrics.shape_from_h5`.
- Produces: `save*` return dicts carry `shape_crest_factor / shape_near_peak_count / shape_sample_count / shape_axis` (present only when the `.h5` had usable samples).
- [ ] **Step 1: Write the failing test** (drives the BW-import path, which the existing suite already exercises)
```python
# tests/test_save_shape.py
from sfm.waveform_store import WaveformStore
from tests.helpers_bw import sample_bw_bytes, sample_serial # reuse existing import-test fixtures
def test_save_imported_bw_attaches_shape(tmp_path):
store = WaveformStore(tmp_path / "waveforms")
ev, rec = store.save_imported_bw(sample_bw_bytes(), serial=sample_serial())
# A real BW waveform → shape present with a geo axis.
assert rec.get("shape_axis") in ("Tran", "Vert", "Long")
assert rec["shape_crest_factor"] > 0
assert rec["shape_sample_count"] > 200
```
> Reuse whatever fixture `tests/test_save_imported_bw*.py` already uses for BW bytes; match its import. If the existing BW fixture produces a degenerate/short waveform, use the fixture from the test that asserts a full h5.
- [ ] **Step 2: Run to verify it fails**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_save_shape.py -q`
Expected: FAIL — `rec` has no `shape_*` keys.
- [ ] **Step 3: Implementation**
Add a helper near the top of `WaveformStore` methods (module-level import `from sfm.shape_metrics import shape_from_h5`). In each of `save`, `save_imported_bw`, `save_imported_idf`, immediately before building/returning the `rec` dict — and only when the `.h5` was written (i.e. `hdf5_filename`/`hdf5_path` is set) — compute and merge:
```python
shape = shape_from_h5(hdf5_path) if hdf5_filename else None
# ... in the returned rec dict literal, add:
# **(shape and {
# "shape_crest_factor": shape["crest_factor"],
# "shape_near_peak_count": shape["near_peak_count"],
# "shape_sample_count": shape["sample_count"],
# "shape_axis": shape["axis"],
# } or {}),
```
Concretely, after each method computes `hdf5_filename`, add before its `return {...}`:
```python
_shape = shape_from_h5(hdf5_path) if hdf5_filename else None
_shape_rec = {
"shape_crest_factor": _shape["crest_factor"],
"shape_near_peak_count": _shape["near_peak_count"],
"shape_sample_count": _shape["sample_count"],
"shape_axis": _shape["axis"],
} if _shape else {}
```
and spread `**_shape_rec` into the returned dict. (`save_imported_bw`/`save_imported_idf` use their own hdf5 path variable names — use whichever local holds the written `.h5` path in each method.)
- [ ] **Step 4: Run to verify it passes**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_save_shape.py -q`
Expected: PASS.
- [ ] **Step 5: Commit**
```bash
git add sfm/waveform_store.py tests/test_save_shape.py
git commit -m "feat(ingest): compute shape from the written .h5 in all save paths"
```
---
### Task 6: Backfill script for existing events
**Files:**
- Create: `scripts/backfill_event_shape.py` (mirror `scripts/backfill_event_zc_freq.py`, but read the `.h5` for samples instead of the sidecar).
- Test: `tests/test_backfill_event_shape.py`
**Interfaces:**
- Produces: `backfill_shape(db, store, *, dry_run=False) -> dict` with counts `{"updated","skipped_no_h5","skipped_no_samples"}`; `main(argv)` CLI mirroring the zc-freq script's args (`--db-path`, `--store-root`, `--dry-run`).
- [ ] **Step 1: Write the failing test**
```python
# tests/test_backfill_event_shape.py
import numpy as np, h5py
from sfm.database import SeismoDb
from sfm.waveform_store import WaveformStore
from scripts.backfill_event_shape import backfill_shape
from tests.helpers_events import make_event # or inline as in test_zc_freq_columns
def _h5(path, long):
with h5py.File(path, "w") as f:
g = f.create_group("samples")
for k in ("Tran", "Vert"): g.create_dataset(k, data=np.zeros(1024, "float32"))
g.create_dataset("Long", data=np.asarray(long, "float32"))
def test_backfill_updates_shape_and_is_idempotent(tmp_path):
db = SeismoDb(tmp_path / "s.db")
store = WaveformStore(tmp_path / "waveforms")
ev = make_event(serial="BE1", key="0111abcd")
db.insert_events([ev], serial="BE1",
waveform_records={ev._waveform_key.hex():
{"filename": "F.CE0W", "filesize": 10}})
# place the .h5 where store.paths_for expects it
long = np.zeros(1024); long[100] = 0.48
_h5(store.hdf5_path_for("BE1", "F.CE0W"), long)
c1 = backfill_shape(db, store)
assert c1["updated"] == 1
row = db.query_events(serial="BE1")[0]
assert row["shape_axis"] == "Long" and row["shape_near_peak_count"] <= 3
c2 = backfill_shape(db, store) # idempotent: re-run overwrites same values
assert db.query_events(serial="BE1")[0]["shape_crest_factor"] == row["shape_crest_factor"]
```
> Match `make_event` / column names to whatever `tests/test_zc_freq_columns.py` uses. `store.hdf5_path_for(serial, filename)` is the existing helper that returns the `.h5` path.
- [ ] **Step 2: Run to verify it fails**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_backfill_event_shape.py -q`
Expected: FAIL — `ModuleNotFoundError: scripts.backfill_event_shape`.
- [ ] **Step 3: Implementation** (mirror the zc-freq script structure)
```python
#!/usr/bin/env python3
"""Backfill events.shape_* from each event's .h5 waveform samples. Idempotent."""
from __future__ import annotations
import argparse, logging, sys
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from sfm.database import SeismoDb
from sfm.waveform_store import WaveformStore
from sfm.shape_metrics import shape_from_h5
log = logging.getLogger("backfill_event_shape")
def backfill_shape(db: SeismoDb, store: WaveformStore, *, dry_run: bool = False) -> dict:
counts = {"updated": 0, "skipped_no_h5": 0, "skipped_no_samples": 0}
for row in db.query_events(limit=1_000_000):
serial, filename = row.get("serial"), row.get("blastware_filename")
if not serial or not filename:
counts["skipped_no_h5"] += 1; continue
h5_path = store.hdf5_path_for(serial, filename)
if not h5_path.exists():
counts["skipped_no_h5"] += 1; continue
shape = shape_from_h5(h5_path)
if shape is None:
counts["skipped_no_samples"] += 1; continue
if not dry_run:
with db._connect() as conn:
conn.execute(
"UPDATE events SET shape_crest_factor=?, shape_near_peak_count=?, "
"shape_sample_count=?, shape_axis=? WHERE id=?",
(shape["crest_factor"], shape["near_peak_count"],
shape["sample_count"], shape["axis"], row["id"]))
counts["updated"] += 1
log.info("backfill_shape: %s", counts)
return counts
def main(argv=None) -> int:
ap = argparse.ArgumentParser()
ap.add_argument("--db-path", required=True)
ap.add_argument("--store-root", required=True)
ap.add_argument("--dry-run", action="store_true")
a = ap.parse_args(argv)
logging.basicConfig(level=logging.INFO)
counts = backfill_shape(SeismoDb(a.db_path), WaveformStore(a.store_root), dry_run=a.dry_run)
print(counts)
return 0
if __name__ == "__main__":
raise SystemExit(main())
```
> `store.hdf5_path_for` and `db._connect` are existing internals used the same way by other scripts. If `hdf5_path_for` isn't public, use `store.paths_for(...)` sibling `.h5` path exactly as `save()` derives `hdf5_path`.
- [ ] **Step 4: Run to verify it passes**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_backfill_event_shape.py -q`
Expected: PASS.
- [ ] **Step 5: Run the full suite + commit**
```bash
/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest -q
git add scripts/backfill_event_shape.py tests/test_backfill_event_shape.py
git commit -m "feat(scripts): backfill events.shape_* from .h5 samples"
```
---
### Task 7: Confirm /db/events carries shape + version bump
**Files:**
- Test: `tests/test_db_events_exposes_shape.py`
- Modify: `pyproject.toml` version; `sfm/server.py` version string; `CHANGELOG.md`.
**Interfaces:**
- Consumes: the running `/db/events` route (already returns `SELECT *`).
- [ ] **Step 1: Write the failing test** (guards that the feed dict includes the new keys)
```python
# tests/test_db_events_exposes_shape.py
from sfm.database import SeismoDb
def test_query_events_row_includes_shape_keys(tmp_path):
db = SeismoDb(tmp_path / "s.db")
# query_events returns dict(row); a fresh insert has the keys (values may be None)
from tests.helpers_events import make_event
db.insert_events([make_event(serial="BE1", key="0111abcd")], serial="BE1")
row = db.query_events(serial="BE1")[0]
for k in ("shape_crest_factor","shape_near_peak_count","shape_sample_count","shape_axis"):
assert k in row
```
- [ ] **Step 2: Run to verify it fails / passes**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest tests/test_db_events_exposes_shape.py -q`
Expected: PASS immediately if Task 3 landed (columns present in `SELECT *`). If it fails, the columns weren't added — fix Task 3. (This task is the guard, not new behavior.)
- [ ] **Step 3: Version bump**
Bump `pyproject.toml` `version` 0.23.0 → 0.24.0; set `sfm/server.py` `version="0.24.0"`; add a `## v0.24.0` CHANGELOG entry ("waveform-shape metrics on events: crest factor + points-near-peak, ingest + backfill").
- [ ] **Step 4: Full suite**
Run: `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest -q`
Expected: PASS (no regressions).
- [ ] **Step 5: Commit**
```bash
git add tests/test_db_events_exposes_shape.py pyproject.toml sfm/server.py CHANGELOG.md
git commit -m "chore(release): v0.24.0 — waveform-shape metrics on events"
```
---
## Self-Review
**Spec coverage:** SFM shape columns (Tasks 3–4) ✓; DSP crest + near-peak (Task 1) ✓; ingest population (Task 5) ✓; backfill (Task 6) ✓; `/db/events` exposure (Task 7) ✓; NULL for histogram/no-sample events (Tasks 1/5/6 return None → NULL) ✓; 94%-coverage / series-4 fallback handled by NULL-then-Terra-View-fallback (Phase B) ✓. Terra-View scoring, 3-state review, twin flagging, export Notes column → **Phase B plan** (separate, depends on this feed). Calibration → Phase C.
**Placeholder scan:** No TBD/TODO; every code step has real code. The two "reuse existing fixture" notes point at concrete existing tests (`test_zc_freq_columns.py`, `test_save_imported_bw*.py`) rather than leaving blanks.
**Type consistency:** `shape_from_h5`/`shape_from_samples`/`channel_shape` return the same dict keys (`crest_factor`, `near_peak_count`, `sample_count`, `axis`) throughout; the DB columns (`shape_crest_factor`, `shape_near_peak_count`, `shape_sample_count`, `shape_axis`) and rec keys match across Tasks 4–6.
## Deferred to Phase B (terra-view, separate plan)
Scoring service combining shape + cheap signals; suspicion column + reason chips; `reviewed_real` mirror + 3-state review; twin-aware flag propagation; Notes-column export + Maximums "(excludes N flagged)". Written once this feed is live so column names/values are real.
@@ -1,264 +0,0 @@
# Phase B2-A (seismo-relay) — reviewed_real + 3-state mirror + twin propagation
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** Give SFM a persisted, queryable `reviewed_real` flag alongside `false_trigger` (mirrored from the sidecar review block, mutually exclusive), and propagate a review to an event's histogram/waveform twin so flagging one flags both.
**Architecture:** Mirror the existing `false_trigger` mechanism. New `events.reviewed_real` column (auto-migrate). `update_event_review` mirrors BOTH flags from the sidecar review block and enforces mutual exclusivity on the columns. A `find_twins` matcher (same serial + identical peak_vector_sum + timestamp within a window) drives `propagate_review_to_twins`, which the sidecar-PATCH endpoint calls after mirroring the primary. Terra-View reads `reviewed_real` from `/db/events` (SELECT *).
**Tech Stack:** Python 3.10, raw sqlite3, FastAPI, pytest. Runner: `/home/serversdown/seismo-relay/.venv/bin/python3`.
## Global Constraints
- 3 review states are **mutually exclusive**: an event is `false_trigger=1` XOR `reviewed_real=1` XOR neither. Setting one true forces the other's column to 0.
- The sidecar JSON stays the source of truth for full review state; the `false_trigger`/`reviewed_real` columns are derived indexes (like today). B2-A propagates twins at the **column** level (what the feed/peak/export read); twin sidecars are not rewritten (known limitation — noted).
- Twin match = **same serial AND identical `peak_vector_sum` (exact equality) AND `timestamp` within ± window (default 300 s), excluding the event itself.** Identical PVS is the safety anchor.
- Known pre-existing test failures (~16, missing gitignored fixtures under `tests/fixtures/`) are unrelated — confirm zero NEW failures, don't try to fix them.
- Run tests with `/home/serversdown/seismo-relay/.venv/bin/python3 -m pytest`.
---
### Task 1: `reviewed_real` column on events
**Files:** Modify `sfm/database.py` (`_SCHEMA` CREATE TABLE `events` + the Migration-1 rebuild `CREATE TABLE` + the `_migrate` ADD COLUMN loop). Test: `tests/test_reviewed_real_column.py`.
**Interfaces:** Produces `events.reviewed_real INTEGER NOT NULL DEFAULT 0`.
- [ ] **Step 1: Failing test**
```python
# tests/test_reviewed_real_column.py
import sqlite3
from sfm.database import SeismoDb
def _cols(db):
with sqlite3.connect(db.db_path) as c:
return {r[1] for r in c.execute("PRAGMA table_info(events)")}
def test_fresh_db_has_reviewed_real(tmp_path):
assert "reviewed_real" in _cols(SeismoDb(tmp_path/"s.db"))
def test_existing_db_migrates_reviewed_real(tmp_path):
p = tmp_path/"s.db"; db = SeismoDb(p)
with sqlite3.connect(p) as c:
c.execute("ALTER TABLE events DROP COLUMN reviewed_real")
assert "reviewed_real" not in _cols(db) # dropped (read via existing handle/connection)
SeismoDb(p) # re-open migrates
assert "reviewed_real" in _cols(SeismoDb(p))
```
> If sqlite < 3.35 lacks DROP COLUMN, fall back to building a table without the column and asserting re-open adds it (same as the shape-columns test did).
- [ ] **Step 2: Run → FAIL** (`pytest tests/test_reviewed_real_column.py -q`).
- [ ] **Step 3: Implement**
- In `_SCHEMA` `events` CREATE TABLE, after the `false_trigger ... DEFAULT 0,` line add: ` reviewed_real INTEGER NOT NULL DEFAULT 0, -- 0=no, 1=operator-confirmed real (mutually exclusive with false_trigger)`
- In the `_migrate` ADD COLUMN loop tuple add: `("reviewed_real", "INTEGER NOT NULL DEFAULT 0"),`
- **Do NOT** add it to the Migration-1 rebuild `CREATE TABLE events (...)` block — that block uses a positional `INSERT ... SELECT * FROM events_old` and, by convention, contains only the columns that existed when Migration 1 was written; every later column is added by the ADD COLUMN loop only. Adding it there crashes `_migrate` on genuinely legacy (pre-Migration-1) DBs.
- [ ] **Step 4: Run → PASS.**
- [ ] **Step 5: Commit** `feat(db): reviewed_real column on events (+ auto-migrate)`
---
### Task 2: `update_event_review` mirrors both flags + mutual exclusivity
**Files:** Modify `sfm/database.py` `update_event_review`. Test: `tests/test_update_event_review_reviewed_real.py`.
**Interfaces:** Consumes a `review` dict that may carry `false_trigger` and/or `reviewed_real` (bools). Produces mutually-exclusive column state.
- [ ] **Step 1: Failing test**
```python
# tests/test_update_event_review_reviewed_real.py
from sfm.database import SeismoDb
from minimateplus.models import Event
def _ins(db, eid_key="01110000", serial="BE1"):
ev = Event(index=0); ev._waveform_key = bytes.fromhex(eid_key)
db.insert_events([ev], serial=serial)
return db.query_events(serial=serial)[0]["id"]
def test_confirm_real_sets_and_clears_ft(tmp_path):
db = SeismoDb(tmp_path/"s.db"); eid = _ins(db)
db.update_event_review(eid, {"false_trigger": True})
assert db.get_event(eid)["false_trigger"] == 1
db.update_event_review(eid, {"reviewed_real": True}) # confirming real clears FT
row = db.get_event(eid)
assert row["reviewed_real"] == 1 and row["false_trigger"] == 0
def test_flag_ft_clears_reviewed_real(tmp_path):
db = SeismoDb(tmp_path/"s.db"); eid = _ins(db)
db.update_event_review(eid, {"reviewed_real": True})
db.update_event_review(eid, {"false_trigger": True})
row = db.get_event(eid)
assert row["false_trigger"] == 1 and row["reviewed_real"] == 0
```
> Build the Event inline like `tests/test_zc_freq_columns.py` if the import differs.
- [ ] **Step 2: Run → FAIL.**
- [ ] **Step 3: Implement** — replace the body of `update_event_review` so it handles both keys:
```python
if not isinstance(review, dict):
return False
has_ft = "false_trigger" in review
has_real = "reviewed_real" in review
if not has_ft and not has_real:
with self._connect() as conn:
row = conn.execute("SELECT 1 FROM events WHERE id=?", (event_id,)).fetchone()
return row is not None
sets = {}
if has_ft:
sets["false_trigger"] = 1 if review.get("false_trigger") else 0
if has_real:
sets["reviewed_real"] = 1 if review.get("reviewed_real") else 0
# mutual exclusivity: a true in one forces the other column to 0
if sets.get("false_trigger") == 1:
sets["reviewed_real"] = 0
if sets.get("reviewed_real") == 1:
sets["false_trigger"] = 0
assign = ", ".join(f"{k}=?" for k in sets)
params = list(sets.values()) + [event_id]
with self._connect() as conn:
cur = conn.execute(f"UPDATE events SET {assign} WHERE id=?", params)
return cur.rowcount > 0
```
- [ ] **Step 4: Run → PASS** (+ run `tests/test_*false_trigger*`/existing review tests to confirm no regression).
- [ ] **Step 5: Commit** `feat(db): update_event_review mirrors reviewed_real + enforces 3-state exclusivity`
---
### Task 3: `find_twins` matcher
**Files:** Modify `sfm/database.py` (add `find_twins`). Test: `tests/test_find_twins.py`.
**Interfaces:** Produces `find_twins(event_id, *, window_seconds=300) -> list[dict]` — same serial, identical peak_vector_sum, timestamp within ±window, excluding self.
- [ ] **Step 1: Failing test**
```python
# tests/test_find_twins.py
import datetime
from sfm.database import SeismoDb
from minimateplus.models import Event, Timestamp
def _ins(db, key, serial, pvs, ts):
ev = Event(index=0); ev._waveform_key = bytes.fromhex(key)
ev.timestamp = ts
# peak_vector_sum comes from peak_values; simplest: insert then UPDATE pvs directly
db.insert_events([ev], serial=serial)
row = [r for r in db.query_events(serial=serial) if r["waveform_key"] == key][0]
import sqlite3
with sqlite3.connect(db.db_path) as c:
c.execute("UPDATE events SET peak_vector_sum=? WHERE id=?", (pvs, row["id"]))
return row["id"]
def test_find_twins_matches_same_serial_pvs_near_time(tmp_path):
db = SeismoDb(tmp_path/"s.db")
base = Timestamp(raw=b"", flag=0x10, year=2026, unknown_byte=0, month=2, day=25, hour=20, minute=19, second=5)
twin = Timestamp(raw=b"", flag=0x10, year=2026, unknown_byte=0, month=2, day=25, hour=20, minute=19, second=45)
far = Timestamp(raw=b"", flag=0x10, year=2026, unknown_byte=0, month=2, day=25, hour=21, minute=0, second=0)
a = _ins(db, "01110001", "BE1", 0.4763, base)
b = _ins(db, "01110002", "BE1", 0.4763, twin) # twin: same serial+pvs, 40s apart
c = _ins(db, "01110003", "BE1", 0.4763, far) # same pvs but >window away
d = _ins(db, "01110004", "BE1", 0.9999, twin) # near time but different pvs
ids = {r["id"] for r in db.find_twins(a, window_seconds=300)}
assert ids == {b}
```
> Adjust the Event/Timestamp construction to match how `tests/test_waveform_store.py::_make_synthetic_event` builds them if fields differ.
- [ ] **Step 2: Run → FAIL.**
- [ ] **Step 3: Implement**
```python
def find_twins(self, event_id: str, *, window_seconds: int = 300) -> list[dict]:
row = self.get_event(event_id)
if not row:
return []
serial = row.get("serial"); pvs = row.get("peak_vector_sum"); ts = row.get("timestamp")
if serial is None or pvs is None or not ts:
return []
try:
t = datetime.datetime.fromisoformat(ts.replace(" ", "T"))
except ValueError:
return []
lo = (t - datetime.timedelta(seconds=window_seconds)).isoformat()
hi = (t + datetime.timedelta(seconds=window_seconds)).isoformat()
with self._connect() as conn:
rows = conn.execute(
"SELECT * FROM events WHERE serial=? AND id!=? AND peak_vector_sum=? "
"AND timestamp BETWEEN ? AND ?",
(serial, event_id, pvs, lo, hi),
).fetchall()
return [dict(r) for r in rows]
```
- [ ] **Step 4: Run → PASS.**
- [ ] **Step 5: Commit** `feat(db): find_twins (serial + identical PVS + time window)`
---
### Task 4: propagate a review to twins + wire into the sidecar-PATCH endpoint
**Files:** Modify `sfm/database.py` (add `propagate_review_to_twins`); `sfm/server.py` (`db_event_sidecar_patch`). Test: `tests/test_twin_propagation.py`.
**Interfaces:** `propagate_review_to_twins(event_id, *, window_seconds=300) -> list[str]` copies the event's `false_trigger`/`reviewed_real` columns onto each twin; returns twin ids.
- [ ] **Step 1: Failing test** (DB-level)
```python
# tests/test_twin_propagation.py — reuse the _ins helper pattern from test_find_twins
def test_propagate_copies_flags_to_twins(tmp_path):
db = SeismoDb(tmp_path/"s.db")
# (build primary + twin via the _ins helper as in test_find_twins)
# flag the primary FT, then propagate:
db.update_event_review(primary_id, {"false_trigger": True})
moved = db.propagate_review_to_twins(primary_id)
assert twin_id in moved
assert db.get_event(twin_id)["false_trigger"] == 1
```
- [ ] **Step 2: Run → FAIL.**
- [ ] **Step 3: Implement**
- `sfm/database.py`:
```python
def propagate_review_to_twins(self, event_id: str, *, window_seconds: int = 300) -> list[str]:
row = self.get_event(event_id)
if not row:
return []
ft = 1 if row.get("false_trigger") else 0
real = 1 if row.get("reviewed_real") else 0
twins = self.find_twins(event_id, window_seconds=window_seconds)
moved = []
with self._connect() as conn:
for tw in twins:
conn.execute("UPDATE events SET false_trigger=?, reviewed_real=? WHERE id=?",
(ft, real, tw["id"]))
moved.append(tw["id"])
return moved
```
- `sfm/server.py` `db_event_sidecar_patch`: after the existing `_get_db().update_event_review(event_id, new_sidecar.get("review", {}))`, add:
```python
# Propagate the review to the event's histogram/waveform twin(s) so
# flagging one flags both (column-level; twins share serial+PVS+near time).
try:
_get_db().propagate_review_to_twins(event_id)
except Exception as exc:
log.warning("twin review-propagation failed for %s: %s", event_id, exc)
```
(Guard the `if body.review is not None:` block so propagation only runs when review changed.)
- [ ] **Step 4: Run → PASS.**
- [ ] **Step 5: Commit** `feat(review): propagate false_trigger/reviewed_real to twins on sidecar PATCH`
---
### Task 5: expose in feed guard + version bump
**Files:** Test `tests/test_reviewed_real_in_feed.py`; `pyproject.toml`, `sfm/server.py` version, `CHANGELOG.md`.
- [ ] **Step 1: Guard test** — a `query_events` row dict includes `reviewed_real` (SELECT * returns it).
```python
from sfm.database import SeismoDb
from minimateplus.models import Event
def test_query_events_includes_reviewed_real(tmp_path):
db = SeismoDb(tmp_path/"s.db")
ev = Event(index=0); ev._waveform_key = bytes.fromhex("01110000")
db.insert_events([ev], serial="BE1")
assert "reviewed_real" in db.query_events(serial="BE1")[0]
```
- [ ] **Step 2: Run → PASS** (columns already present from Task 1).
- [ ] **Step 3: Bump** `pyproject.toml` 0.24.0 → 0.25.0; `sfm/server.py` version="0.25.0"; add `## v0.25.0` CHANGELOG entry ("reviewed_real 3-state review flag + histogram/waveform twin review-propagation").
- [ ] **Step 4: Full suite** — confirm zero NEW failures beyond the ~16 pre-existing.
- [ ] **Step 5: Commit** `chore(release): v0.25.0 — reviewed_real + twin review-propagation`
---
## Self-Review
**Spec coverage:** reviewed_real column (T1) ✓; mirror + mutual exclusivity (T2) ✓; twin match serial+identical-PVS+window (T3) ✓; twin propagation wired into the review path (T4) ✓; feed exposure + version (T5) ✓. Twin **sidecar** rewrite intentionally deferred (column-level only — documented in Global Constraints); this is the SFM half — the 3-state UI + confirm-real PATCH is the separate **B2-B (terra-view)** plan.
**Placeholder scan:** none — every step has real code (the two "adjust Event construction to match test_waveform_store" notes point at a concrete existing helper).
**Type consistency:** `false_trigger`/`reviewed_real` INTEGER columns used identically across T1/T2/T4; `find_twins`→`propagate_review_to_twins` both key on the same match; server calls the DB methods by the exact names T2–T4 define.
@@ -1,134 +0,0 @@
# Plan — "Rescue Listener": a first-class tool for the inverted rescue
**Status:** proposal, not started. Written 2026-09-17 ~01:40 local, straight
off the BE12599 incident. Open questions at the bottom need Brian's answer
before anything is built.
**Background:** `docs/runbooks/wedged_unit_recovery.md`, "Second incident —
BE12599". The manual version of this worked; this plan is about making it a
tool instead of a sequence of remembered steps at 1 AM.
---
## The problem, stated plainly
When a unit is wedged in the BE12599 mode — geophone offset above trigger,
recording back-to-back, ACH dialing constantly, device stuck repeating an AT
modem-init string and therefore **deaf to S3 over inbound** — the only channel
that works is the one the *device* opens.
Recovering it currently means:
1. Remember that `bridges/ach_server.py` exists and takes the right flags
2. Start it by hand on a box the modem can reach, with a public port forwarded
3. Go into ACEmanager and repoint the modem's Destination
4. Watch a terminal for a call-in
5. Read `rescue.json` to find out whether it worked
6. Go back into ACEmanager and repoint the modem to where it belongs
7. **Not forget step 6**, because leaving the Destination pointed at a dead
listener is worse than never having started
That is six manual steps and one landmine, executed under pressure while a
unit floods the office server.
## What the tool should be
**A "rescue listener" an operator can start for one unit, which handles
whatever that unit says when it calls in, and refuses to go away until the
operator confirms the modem has been pointed back.**
Lifecycle:
1. **Start** — operator names the target unit and starts a rescue listener.
The tool reports the exact address/port to enter in ACEmanager, plus the
actions it will take.
2. **Operator repoints the modem** to that address.
3. **Wait** — listener sits there. Live status: "waiting for call-in",
elapsed, last-seen.
4. **Act** — on call-in, run the configured rescue actions automatically,
in a safe order, each independently guarded. Report per-action outcome.
5. **Hold** — the listener **stays up** and keeps reporting, because the
modem is still pointed at it.
6. **Confirm & stop** — the operator explicitly confirms the Destination has
been restored (to `0.0.0.0`, or to the office Instantel ACH server).
Only then does the listener shut down.
Step 6 is the whole point of making this a tool. It is the step that is
easiest to skip and most expensive to skip.
## Default action set
Ordered deliberately — see "order matters" below.
| # | Action | Default | Why |
|---|---|---|---|
| 1 | **Stop monitoring** (SUB 0x97) | ✅ on | Halts recording; ends the trigger→record→dial loop at its source. Already implemented as `--stop-monitoring`. |
| 2 | **Drain events** to a diagnostics store | ⚙ configurable | The backlog is usually evidence, not garbage — see the BE12599 offset investigation. Must NOT land in the prod SFM DB. |
| 3 | **Disable ACH** (SUB 0x2C/0x7E/0x7F) | ❌ off by default | Stops the dialing — **and stops your only channel**. Opt-in, and ideally gated on step 1 having succeeded. |
| 4 | **Erase events** | ❌ off by default | Destructive. Only after a verified drain. |
### Order matters — the lesson from BE12599
Stopping monitoring *removes the call-in trigger*. ACH fires on "after event
recorded"; with recording stopped, the unit has no reason to dial again, even
though the backlog is still sitting in its memory. So a naive
"stop + disable + erase, all at once" rescue can silence the unit before
you've collected anything, leaving you with no channel and a device full of
evidence.
The tool should either sequence around this or warn loudly about it. My
instinct is: **stop monitoring immediately** (it's the bleeding), then drain
across however many call-ins it takes, and treat disable-ACH/erase as a
separate, explicit "finish" action once the operator is satisfied.
## Where it should live — open question, with a proposal
The natural tier is **SFM** (device-side, per the three-tier model in
CLAUDE.md). But the rescue listener must be reachable *from the cellular
network*, which is a deployment constraint SFM's usual profile doesn't have.
**Proposal worth considering:** run it at the office, beside the real Instantel
ACH server, on a **different port** (e.g. 12346 while Instantel holds 12345).
Then the ACEmanager change is a **port change, not an IP change** — smaller,
faster, less to get wrong, and trivially reversible. It also means the office
public IP (already stable and known) is the destination, rather than whatever
Brian's dynamic home IP happens to be that week.
The tmi-dev approach used on BE12599 worked, but required a router forward and
ran into the dynamic-IP problem in the same session.
## Open questions
1. **Where does it run?** Office beside Instantel ACH (port swap), SFM on the
NAS, or ad-hoc on tmi-dev? Affects everything else.
2. **What drives it?** Terra-View admin page (fits "operator UI"), an SFM
endpoint pair (`POST /device/rescue_listener/start` + `/stop` + `/status`),
or a CLI wrapper? A long-lived listener doesn't fit the request/response
endpoint shape well — probably needs a background task with a status poll.
3. **How does it identify the unit?** It can't know the serial until the
device calls in and the handshake reads it. Allowlist by modem IP? Accept
anything and report what showed up?
4. **Where do drained events go?** A per-incident diagnostics store
(`bridges/captures/<unit>-diag`) seems right — explicitly *not* the prod
SFM DB. Does that store need to be a first-class thing with its own
retention, or is a directory fine?
5. **How is "confirm the modem is repointed" verified?** Operator attestation
(a button), or can we actually probe it? If the listener stops seeing
call-ins that's weak evidence; if inbound to the unit starts working that's
stronger.
6. **Multi-unit?** One listener per incident, or one listener that handles any
unit that dials in? Probably the former for safety.
7. **Timeout / abandonment policy.** If nobody ever confirms, does it run
forever? Alert after N hours?
## What already exists
- `bridges/ach_server.py` — the listener itself, with `--stop-monitoring`,
`--disable-ach`, `--rescue` (added on `feat/ach-rescue-on-connect`, commit
`9f1050b`), `--clear-after-download`, `--max-events`, `--allow-ip`.
- Per-session `rescue.json` recording per-action outcomes.
- Isolated per-output-dir SQLite + waveform store, so a diagnostics capture is
already separate from prod by construction.
So the gap is not protocol work — it's lifecycle, operator surface, and the
confirmation gate. Most of the risk is in questions 1 and 2.
File diff suppressed because it is too large. Load diff
File diff suppressed because it is too large. Load diff
File diff suppressed because it is too large. Load diff
File diff suppressed because it is too large. Load diff
@@ -1,207 +0,0 @@
# SFM phase 1c — the webapp on the serial-based endpoints, plus wrong-series safeguards
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** The SFM standalone page (`sfm/sfm_webapp.html`) drives both series through the serial-based device endpoints. In addition, no MiniMate-only write or erase can reach a unit that has not identified itself as Series 3.
**Architecture:**
- **Server:** one helper refuses the legacy Series-3 write/erase routes unless the unit's own serial (read on the same connection) says Series 3.
- **Page:** the series routing and button rules live in a marked block of pure functions, tested through Node. The DOM wiring calls those functions and nothing else to build a `/device/` URL or decide a button's state.
**Tech Stack:** Python 3.10 / FastAPI (`sfm/server.py`), vanilla JS in one HTML file, pytest. Node 20 (`~/.local/bin/node`) runs the page-logic tests.
**Spec:** `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` covers "The webapp", "Scope: the parity table" rows 1–5 and 7, and "Build phases" 1c. The design agreed with Brian on 2026-10-28 is recorded in the Global Constraints below.
## Global Constraints
- Work in worktree `~/seismo-relay-parity`, on branch `feat/series4-sfm-parity`. Never commit to `main`. Check with `git branch --show-current` before every commit.
- Run tests with `/home/serversdown/seismo-relay/.venv/bin/python -m pytest -q -p no:cacheprovider`. The baseline is **16 known failures** (15 in `test_bw_ascii_report.py`, 1 in `test_event_file_io.py`). Read the failure list before committing. A `pytest | tail` exits 0.
- **Serial optional:** with a serial, the Live tabs use the serial-based endpoints: `/device/info`, `/device/monitor/status`, `/device/settings`, `/device/events`, `POST /device/events/download`, and `POST /device/monitor/start|stop` (all with `serial=`), plus `POST /device/hangup?host=&tcp_port=`. With the serial blank, every read behaves exactly as today.
- **Series comes from the unit's reply.** The badge and every series-specific control follow the `series` field of the last `/device/info` reply, and only if its `serial` equals the typed one. A typed serial alone never enables a series-specific control.
- **Write buttons:**
- Start/stop use the audited serial path for both series.
- Config write and Call-Home write are **disabled for both series**. Their tooltips read exactly "Coming in phase 5 (#46)" and "Coming in phase 4".
- Diagnostics (erase, rescue, slow drip, blind stop) is enabled only when the confirmed series is 3.
- Hang up is shown only when the confirmed series is 4.
- **Start feedback:** while a start is in flight, show "Starting — the unit runs its sensor check first (about 35 s)". The legacy 60-second `_pollMonitorConfirm` loop is not used in serial mode.
- **Results are reported as SFM returned them:** outcome, verified, state before → after, and the first 8 characters of the audit id. HTTP error `detail` strings are shown verbatim.
- **Speed (Brian):** no new request may be added to a path unless the plan says why. The server identity check reuses the serial that `connect()` already reads. On `rescue` and `POST /device/call_home` it adds exactly one SUB 0x15 read.
- No codec, store or DB change. The legacy `/device/*` routes keep their URLs and parameters (a new optional `serial` is added).
## Review Focus
1. **A typed `BE…` serial at an address that holds a Micromate.** The server must refuse every guarded route with 409 and send no write. In the page, Diagnostics stays disabled until `/device/info` answers Series 3. Pinned by Task 1 (`test_guarded_route_refuses_a_unit_that_answers_as_series4`) and Task 2 (`controls: typed serial is not confirmation`).
2. **The serial is edited after a successful identify.** The confirmation must stop counting the moment the typed serial no longer matches. Pinned by Task 2 (`controls: confirmation drops when the serial changes`).
3. **Lower-case or space-padded serials** (`" be9441 "`) are normalised the same way the server normalises them. Pinned by Task 2 (`seriesFromSerial` and `unitQuery` cases).
4. **A start that times out (504) or reads back a mismatch (409).** The page must show the server's detail and the audit id, never "started". Pinned by Task 2 (`changeSummary` cases for `failed`/`mismatch`) and Task 5 (an error-path render).
5. **A download that is already stored** (`inserted: false`) is reported as "already stored" and still opens the stored event. Pinned by Task 2 (`downloadSummary`).
---
### Task 1: Server — legacy Series-3 writes refuse a unit that isn't Series 3
**Files:**
- Modify: `sfm/server.py`:
- `device_config` (~1107), `device_events_erase` (~1427), `device_rescue` (~1763), the `device_call_home` POST (~2066);
- `device_config_project` passes `serial` through.
- Modify: `minimateplus/client.py`: add `MiniMateClient.read_serial()`.
- Test: create `tests/test_server_series3_guard.py`.
**Interfaces:**
- Produces: `MiniMateClient.read_serial(self) -> str`. Requires an open, polled session. It runs the SUB 0x15 read (`self._require_proto().read(SUB_SERIAL_NUMBER)`) and returns `_decode_serial_number(...).serial`.
- Produces: `sfm.server._require_series3(unit_serial: Optional[str], expected: Optional[str]) -> None`. It raises `HTTPException(409, detail)` when either:
- `series_for_serial(unit_serial)` is not 3 (an unknown serial counts as not 3), with detail `f"the unit at this address answers as {unit_serial!r}, not a Series-3 unit -- nothing sent"`; or
- `expected` is given and `normalise_serial(expected) != normalise_serial(unit_serial)`, with detail `f"the unit at this address is {unit_serial}, not {expected} -- nothing sent"`.
- Each guarded route gains `serial: Optional[str] = Query(None, description=_SERIAL_DOC)`. It calls the guard right after it knows the unit's serial, and before its first write:
- `device_config` and `device_events_erase`: `info = client.connect()` → `_require_series3(info.serial, serial)`;
- `device_rescue` and `device_call_home` (POST): after `client.poll()` → `_require_series3(client.read_serial(), serial)`.
- Not guarded, and each gets a one-line comment saying why: legacy `monitor/start|stop`, `stop_monitoring_blind`, `stop_monitoring_slow_drip`, `stop_monitoring_spam`. They send only `0x96`/`0x97`, which mean the same on both series (measured 2026-10-25/27), and the rescue tools must work on a unit too wedged to answer.
- [ ] **Step 1: Write the failing tests** in `tests/test_server_series3_guard.py`. Use `monkeypatch.setattr(srv, "_build_client", factory)` as `tests/test_server_device_access.py:398` does. The fake client records every call:
- `test_guarded_route_refuses_a_unit_that_answers_as_series4[route]`: parametrise over the four routes. The fake's `connect()` returns a `DeviceInfo(serial="UM20147")`, or its `read_serial()` returns `"UM20147"`. Assert `HTTPException.status_code == 409`, and that the recorded calls contain no write method (`delete_all_events`, `apply_config`, `set_call_home_config`, `stop_monitoring`).
- `test_guarded_route_refuses_a_different_series3_unit`: the unit answers `"BE9441"`, the request names `serial="BE12599"`, so the response is 409 with `"not BE12599"` in the detail.
- `test_guarded_route_proceeds_for_the_named_series3_unit`: the unit answers `"BE9441"` with `serial="be9441 "` (normalised), and the write method is called once.
- `test_unguarded_stop_routes_send_without_an_identity_read`: `stop_monitoring_blind` (it writes through a bare `TcpTransport`; stub `srv.TcpTransport`) sends its stop frames, and nothing builds a client or reads a serial.
- [ ] **Step 2: Run them.** `…pytest tests/test_server_series3_guard.py -q` → FAIL (`_require_series3` / `read_serial` don't exist).
- [ ] **Step 3: Implement** `read_serial`, `_require_series3`, the `serial` query parameter, and the four guard calls as specified.
- [ ] **Step 4: Run** the new tests plus `tests/test_server_device_access.py` → PASS. Then the full suite → only the 16 known failures.
- [ ] **Step 5: Commit** `fix(sfm): legacy Series-3 writes and erase refuse a unit that does not answer as Series 3`.
### Task 2: Page — the device-routing block (pure functions) and its Node-run tests
**Files:**
- Modify: `sfm/sfm_webapp.html`. Add one `<script>` block, delimited by the lines `/* <device-routing> */` and `/* </device-routing> */`. It must not touch `document` or `fetch`.
- Test: create `tests/test_webapp_device_routing.py`. It extracts the block, appends `module.exports = {…}`, and runs cases through `node -e` (via `subprocess`, reading JSON on stdout). Skip with a clear reason if `shutil.which("node")` is `None`.
**Interfaces (Produces, used by Tasks 3–6):**
- `seriesFromSerial(serial) -> 3 | 4 | null`: trims and upper-cases; `UM…` → 4, `BE…`/`BA…` → 3 (prefix plus at least one more character), anything else → `null`. Mirrors `sfm/device_access/series.py`.
- `unitQuery(unit) -> string`, where `unit = {serial, host, tcpPort}`:
- serial mode: `serial=<NORMALISED>&host=<h>&tcp_port=<p>`;
- blank serial: `host=<h>&tcp_port=<p>`;
- every value goes through `encodeURIComponent`.
- `deviceUrl(action, unit, params = {}) -> {method, path}`: `path` is relative, e.g. `/device/info?serial=…`. Actions:
- `info`, `status`, `settings`, `events` → GET;
- `download` (needs `params.event_id`), `start`, `stop` → POST;
- `hangup` → POST, with no `serial` (host/port only);
- legacy actions: `storage_range`, `index`, `erase`, `rescue`, `blind_stop`, `slow_drip`, `call_home_read` (GET `/device/call_home`), `call_home_write`, `config_write` (POST `/device/config`).
`settings`, `download` and `hangup` with a blank serial return `null`, since there is no legacy equivalent. Unknown actions throw.
- `confirmedSeries(unit) -> 3 | 4 | null`, where `unit.confirmed = {serial, series}` comes from the last `/device/info` reply:
- returns `unit.confirmed.series` only when the normalised typed serial equals `unit.confirmed.serial`;
- with a blank typed serial, returns `unit.confirmed.series` from a legacy identify;
- otherwise `null`.
- `controlsFor(unit) -> {startStop, hangup, diagnostics, callHomeRead, configWrite, callHomeWrite, reasons}`, all booleans except `reasons`:
- `startStop` = serial mode and `confirmedSeries ∈ {3, 4}`;
- `hangup` = `confirmedSeries === 4`;
- `diagnostics` = `confirmedSeries === 3`;
- `callHomeRead` = `confirmedSeries === 3`;
- `configWrite` = `callHomeWrite` = `false`;
- `reasons` = `{configWrite: "Coming in phase 5 (#46)", callHomeWrite: "Coming in phase 4"}`.
- `changeSummary(body) -> string`, for a ChangeResult JSON (`action, outcome, verified, state_before, state_after, audit_id, plan`):
- `dry_run` → `"<action>: dry run — would send <subs comma-joined>"`;
- `skipped` → `"<action>: already <state_before> — nothing sent"`;
- `sent` + `ok` → `"<action>: confirmed — <state_before> → <state_after> (audit <id8>)"`;
- anything else → `"<action>: <outcome>, <verified> (audit <id8>)"`.
- `downloadSummary(body) -> string`, for an EventDownload JSON:
- `inserted: false` → `"already stored — <stored_filename>"`;
- otherwise `"stored <stored_filename>, <filesize> bytes, check: <detail.check>"`.
- [ ] **Step 1: Write the failing test file.** Each case is `(function, args, expected)` and runs as `node` evaluating `JSON.stringify(fn(...args))`. Cases that must be present:
- `seriesFromSerial`: `"UM20147"`→4, `" be9441 "`→3, `"BA123"`→3, `"BE"`→null, `"XX1"`→null.
- `unitQuery`: serial mode upper-cases and trims; blank serial omits `serial=`; a host with `&` is encoded.
- `deviceUrl`: `info` with a serial → `{method:"GET", path:"/device/info?serial=BE9441&host=h&tcp_port=9034"}`; `hangup` → no `serial`; `settings` with a blank serial → `null`; `download` carries `event_id`.
- controls (named for Review Focus 1 and 2):
- **typed serial is not confirmation**: typed `BE9441` with `confirmed:null` → `diagnostics:false, startStop:false`;
- **confirmed S3**: diagnostics true, hangup false;
- **confirmed S4**: hangup true, diagnostics false, callHomeRead false;
- **confirmation drops when the serial changes**: confirmed `{serial:"BE9441",series:3}` with typed `BE9442` → all false;
- config/call-home write always false, with the exact reason strings.
- `changeSummary`: one case per outcome, including `failed` with `verified:"not_checked"` and `sent` with `verified:"mismatch"`.
- `downloadSummary`: inserted and already-stored.
- [ ] **Step 2: Run** → FAIL (no block in the page).
- [ ] **Step 3: Implement** the block in the page, just before the existing main `<script>`'s first function. Exactly the functions above, no DOM.
- [ ] **Step 4: Run** → PASS. Full suite → only the 16 known failures.
- [ ] **Step 5: Commit** `feat(webapp): the device-routing rules as pure functions, tested through Node`.
### Task 3: Page — unit bar, series badge, Device tab and status panel, Hang up
**Files:** Modify `sfm/sfm_webapp.html`. Test: extend `tests/test_webapp_device_routing.py` with the static check below.
**Interfaces:**
- Consumes: `unitQuery`, `deviceUrl`, `confirmedSeries`, `controlsFor` (Task 2).
- Produces: a page-level `currentUnit()` returning `{serial, host, tcpPort, confirmed}`. `confirmed` is held in a module variable set only by `connectUnit()` from the `/device/info` reply (`{serial: body.serial, series: body.series}`), and cleared whenever the serial or host field changes. Also `applyControls()`, which sets every series-specific control's `disabled`/`hidden` state and tooltip from `controlsFor(currentUnit())`. Tasks 4–6 call `applyControls()` after any state change.
- [ ] **Step 1: Write the failing static test.** `test_every_device_url_is_built_by_deviceUrl`: outside the device-routing block, the page source contains no `` `${api()}/device/ `` and no `'/device/` string literal. The `deviceUrl` call sites are the only way to build one.
- [ ] **Step 2: Run** → FAIL (today's page builds them by hand).
- [ ] **Step 3: Implement.**
- A **Serial** input beside host/port, `id="dev-serial"`, with placeholder `"BE…/BA… or UM… (optional)"`.
- A badge `id="series-badge"` showing `Series 3` / `Series 4` from `confirmedSeries`, or hidden.
- `connectUnit()` and `refreshMonitorStatus()` go through `deviceUrl('info'|'status', …)`. The Device tab and status panel render `UnitInfo`/`UnitStatus` fields with "—" for null (`device_time` and `event_count` are null on Series 3).
- A **Hang up** button `id="hangup-btn"`, visible only when `controlsFor().hangup`, which POSTs `deviceUrl('hangup')`.
- Convert every remaining hand-built `/device/` URL to `deviceUrl` (legacy actions included), so the static test passes. With a blank serial, behaviour is unchanged.
- [ ] **Step 4: Run** the page tests and the full suite → PASS, only the 16 known failures.
- [ ] **Step 5: Commit** `feat(webapp): name a unit by serial; series badge from the unit's own answer; Hang up for Series 4`.
### Task 4: Page — Events tab by serial
**Files:** Modify `sfm/sfm_webapp.html`.
**Interfaces:**
- Consumes: `deviceUrl('events'|'download')`, `downloadSummary` (Task 2), `currentUnit()` (Task 3), and the existing `openSidecarModal(dbEventId)` (~line 2780).
- [ ] **Step 1: Implement.** In serial mode, the Events tab lists `EventList.events`: index, `timestamp`, `record_type`, PVS and peaks, or "—". Each row has a **Download** button that POSTs `deviceUrl('download', unit, {event_id})`, shows `downloadSummary(body)` in the status bar, and then calls `openSidecarModal(body.db_event_id)` when it isn't null. HTTP errors show `detail` verbatim. With a blank serial, the existing legacy list and waveform behaviour is unchanged.
- [ ] **Step 2: Verify** the page tests and the full suite → only the 16 known failures. The bench check covers the live behaviour.
- [ ] **Step 3: Commit** `feat(webapp): list and download events by serial, for both series`.
### Task 5: Page — Start/Stop through the audited path
**Files:** Modify `sfm/sfm_webapp.html`.
**Interfaces:**
- Consumes: `deviceUrl('start'|'stop')`, `changeSummary`, `controlsFor().startStop` (Task 2).
- [ ] **Step 1: Implement.**
- In serial mode, `startMonitoring()`/`stopMonitoring()` `confirm()` with `"Start monitoring on <serial>?"` / `"Stop monitoring on <serial>?"`.
- Then POST once (never retried). While a start is in flight, show "Starting — the unit runs its sensor check first (about 35 s)".
- Show `changeSummary(body)` for any JSON body, including a 409/502 ChangeResult; show `detail` verbatim for an error without one (e.g. 504).
- Then call `refreshMonitorStatus()`.
- Buttons are enabled only by `controlsFor().startStop`.
- In serial mode the legacy `_pollMonitorConfirm` isn't called. With a blank serial, the legacy behaviour is unchanged.
- [ ] **Step 2: Verify** the page tests and the full suite → only the 16 known failures. Task 2's `changeSummary` cases cover the 409/`mismatch` and `failed` bodies; the bench check covers the live behaviour.
- [ ] **Step 3: Commit** `feat(webapp): start/stop through the audited serial path, with the honest result`.
### Task 6: Page — Config, Call Home and Diagnostics gating
**Files:** Modify `sfm/sfm_webapp.html`.
**Interfaces:**
- Consumes: `deviceUrl('settings'|'call_home_read'|…)`, `controlsFor()` (Task 2), `applyControls()` (Task 3).
- [ ] **Step 1: Implement.**
- **Config tab:** in serial mode, **Read** shows `UnitSettings` (setup name, record mode, sample rate, record time, histogram interval, geo trigger, notes, with "—" for null). **Write** is disabled for both series, with the tooltip from `reasons.configWrite`.
- **Call Home tab:** read enabled only by `callHomeRead`; for Series 4 it says "Not yet available for Series 4". Write is disabled, with `reasons.callHomeWrite`.
- **Diagnostics:** every button is enabled only by `controlsFor().diagnostics`; the erase confirmation stays as is. Diagnostics requests pass `serial` when one is typed, so the server guard (Task 1) checks it as well.
- With a blank serial, the legacy reads are unchanged, while writes and erase follow `controlsFor`. A legacy identify (blank serial) that answers as BE… confirms Series 3.
- [ ] **Step 2: Verify** the page tests and the full suite → only the 16 known failures.
- [ ] **Step 3: Commit** `feat(webapp): config and call-home writes wait for phases 4-5; Diagnostics only for a confirmed Series-3 unit`.
### Task 7: Docs
**Files:** `CLAUDE.md` (the SFM REST API section, and "Where things stand"), `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` (the 1c entry in Build phases).
- [ ] **Step 1:** Document:
- the legacy-route Series-3 guard (which routes, why the stop tools are exempt);
- the page's serial mode;
- the `node` requirement for `tests/test_webapp_device_routing.py`.
No CHANGELOG (feature branch).
- [ ] **Step 2: Commit** `docs: phase 1c -- the webapp by serial, and the Series-3 guard on legacy writes`.
**After Task 7 (controller, with Brian, not an implementer task):** a bench pass on BE9441 and UM20147, through the bridge or cellular:
- identify;
- status;
- settings read;
- events list and one download each;
- one audited start/stop each (Brian's go per send);
- for the Micromate, Hang up;
- Diagnostics disabled on UM20147, and enabled only after BE9441 identifies.
@@ -1,648 +0,0 @@
# Series 3 Decode Checker Implementation Plan
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** A repeatable check that decodes every DL2 Series 3 event file the way SFM ingest does, with no report and no filename, and compares every field, sample and histogram interval with Blastware's `_XML.XML` report. It reports matches, mismatches and gaps, grouped for diagnosis, run after run.
**Architecture:** There are four pieces. Two are pure codec-library modules:
- `bw_xml_report.py` parses the reference.
- `decode_check.py` builds SFM's side from the bytes and compares the two.
A carve-out list sits beside the comparison. Two lab-tool scripts in
`scratch/` do the rest: one runs the corpus in parallel and writes a
results file, the other turns results into the summary, the detailed
report and the run-to-run changes.
**Tech Stack:** Python 3.10, standard library only (`xml.etree.ElementTree`, `concurrent.futures`, `gzip`, `json`), pytest.
**Spec:** `docs/superpowers/specs/2026-10-29-s3-decode-checker-design.md`
## Global Constraints
- Work on branch `feat/s3-decode-checker`, worktree `~/seismo-relay-checker`.
Never commit to `main` or `dev`. **Do not touch `CHANGELOG.md`**: it is
written on dev at merge.
- **Standard library only.** `lxml` is not installed; do not add dependencies.
- **Codec-library modules never import `sfm/`.** These are
`minimateplus/bw_xml_report.py`, `minimateplus/decode_check.py` and
`minimateplus/decode_check_carveouts.py`. Only `scratch/` may import `sfm/`.
- **SFM's side comes only from the event bytes:**
`decode_blastware_bytes(raw, name=None)`. No filename, no report overlay,
and nothing from the XML ever reaches it.
- **SFM's own assumptions are kept:**
- geophone counts become in/s at the Normal range, `10.0 / 32000` per count
(`event_file_io._GEO_NORMAL_FS_INS / _GEO_INT16_FS`)
- mic counts become dB with `waveform_codec.mic_count_to_db`, or psi with
`event_file_io._MIC_FS_PSI`
- the range is never taken from the reference
- **Precision rule:** a number matches when
`|sfm − printed| ≤ 0.5·10^(−decimals in the printed text) + 1e-9`.
Blastware rounds halves away from zero.
- **Verdicts are exactly** `match`, `mismatch`, `sfm_blank`, `accepted`,
`no_reference`, `error`.
- **Series 3 only:** skip `UM…` XMLs. Dedupe binaries by upper-cased basename
(`Sent/` mirrors the root).
- **Run output goes outside the repo.** Default
`~/dl2-archive/checker-runs/<YYYYmmdd-HHMMSS>/`; it contains customer
names, so never commit it.
- **Speed:** a full run (70,042 events, `--jobs 4`) in under 1 h; `--sample
2000` in a few minutes.
- **Tests:** run with `/home/serversdown/seismo-relay/.venv/bin/python -m
pytest`.
- The full suite has 18 known failures in this worktree, and they also fail
on unchanged dev: 15 in `tests/test_bw_ascii_report.py`,
`tests/test_event_file_io.py::test_save_imported_bw_without_report_works_unchanged`,
and 2 in `tests/test_idf_binary_codec.py` (three-channel).
- A task may add **no new** failures.
- **Fixtures:** `tests/fixtures/` is gitignored. Add new fixtures with
`git add -f`.
## Review Focus
1. **Ragged sample rows.** Channels can end at different lengths: in
`T438HGTZ.B30W`, Tran/Vert/MicL stop 3 samples before Long. Blastware's
own table then prints rows with fewer cells, holding the channels still
running, in order. Cells must be attributed by SFM's per-channel lengths,
not by position. That file must come out `match`. A row whose cell count
disagrees with SFM's running channels is a `mismatch` with
`row_length_disagreements` in `detail`; never a silent zip. Tests in Task 3.
2. **The Sensitive range: a clipped 1.250 in/s event** (`M007HVWF.K30W`,
`OORANGE`). SFM's Normal-range values (8× high) must stay `mismatch`; the
saturation carve-out must not swallow them. Test in Task 4.
3. **An event that fails to decode, or an XML that is truncated or
malformed.** That event gets one `error` row and the run continues. Test in
Task 5.
4. **Non-numeric reference text where numbers are expected:** `>100`, `N/A`,
`Check`, `OORANGE`, and units inside the text (`6.7 Volts`, `3.0 sec.`).
These parse without exceptions and map to the rules in Task 3. Tests in
Tasks 1 and 3.
5. **Mic units: `dB(L)` vs `psi(L)` vs none** (`in/s` only, 3 channels, 7
interval columns). The comparison picks SFM's conversion by the reference's
units, and a no-mic event has no MicL rows at all. Tests in Tasks 1 and 3.
---
### Task 1: Fixtures and the XML report parser
**Files:**
- Create: `tests/fixtures/decode-checker-10-29-26/` holding these binaries
plus each one's `<stem>_<ext>_XML.XML`, copied from `~/dl2-archive/files/`
and `~/dl2-archive/xml/`:
- `R352HIUI.F40W`: waveform, setup `BE16352.set`
- `M529L4XQ.R30H`: histogram, relabelled notes
- `T1905KDW.5F0W`: waveform, job number, `>100`, `N/A`, `Check`
- `M007HVWF.K30W`: waveform, range 1.250, `OORANGE`
- `T004JTRF.ME0H`: histogram, `psi(L)`
- `R352HFZ7.530H`: histogram, no mic
- `T438HGTZ.B30W`: waveform, ragged rows, `OORANGE` at range 10.000
- Create: `minimateplus/bw_xml_report.py`
- Test: `tests/test_bw_xml_report.py`
**Interfaces:**
- Produces:
```python
@dataclass
class XmlReport:
scalars: dict[str, str] # tag -> text: top-level simple elements, and
# <Tag><Value>v</Value><Units>u</Units></Tag> -> v
units: dict[str, str] # tag -> the nested <Units> text
event_units: Optional[str] # top-level <Units>, e.g. "in/s and dB(L)"
channels: list[str] # <Channels>/<Channel> in order
job_number: Optional[str]
notes: list[tuple[str, str]] # (tag, value), non-empty, in order, between
# top-level </Units> and <GeoRange>, JobNumber excluded
sample_rows: Optional[list[list[str]]] # waveform: printed cells per row, as-is;
# a row holds only the channels still running
interval_columns: Optional[list[str]] # histogram: ColumnTitle, whitespace collapsed
intervals: Optional[list[tuple[str, list[str]]]] # histogram: (Time, cells)
def parse_xml_report(data: bytes) -> XmlReport
def parse_xml_report_file(path: Union[str, Path]) -> XmlReport
```
- [ ] **Step 1: Copy the seven pairs into the fixture folder** (`cp` from the two dl2 folders; XML names keep the `_XML.XML` form).
- [ ] **Step 2: Write the failing tests** (literal values read from the XMLs):
```python
FIX = Path(__file__).parent / "fixtures/decode-checker-10-29-26"
def test_scalars_units_and_special_text():
r = parse_xml_report_file(FIX / "T1905KDW_5F0W_XML.XML")
assert r.scalars["SampleRate"] == "1024 sps"
assert r.scalars["RecordTime"] == "1.0 sec."
assert r.scalars["TranPPV"] == "0.005" and r.units["TranPPV"] == "in/s"
assert r.scalars["VertZCFreq"] == ">100" # entity unescaped
assert r.scalars["TranZCFreq"] == "N/A"
assert r.scalars["TranTestResults"] == "Check"
assert r.scalars["BatteryLevel"] == "6.7 Volts"
assert r.job_number == "1" and r.notes == []
assert r.channels == ["Tran", "Vert", "Long", "MicL"]
def test_waveform_sample_rows():
r = parse_xml_report_file(FIX / "T1905KDW_5F0W_XML.XML")
assert len(r.sample_rows) == 1024
assert r.sample_rows[0] == ["-0.005", "0.000", "0.000", "81.94"]
assert r.intervals is None
def test_ragged_rows_are_kept_as_printed():
r = parse_xml_report_file(FIX / "T438HGTZ_B30W_XML.XML")
assert len(r.sample_rows) == 2304
assert r.sample_rows[-4] == ["-0.185", "0.235", "-0.255", "-87.96"]
assert r.sample_rows[-1] == ["-0.245"] # only Long still running
def test_relabelled_notes_keep_their_tags_in_order():
r = parse_xml_report_file(FIX / "M529L4XQ_R30H_XML.XML")
assert r.notes == [("Location", "Test Loc")]
r = parse_xml_report_file(FIX / "T004JTRF_ME0H_XML.XML")
assert r.notes[1] == ("Client", "Mele & Mele & Sons, Inc.")
assert r.event_units == "in/s and psi(L)"
def test_histogram_intervals_and_columns():
r = parse_xml_report_file(FIX / "M529L4XQ_R30H_XML.XML")
assert r.interval_columns[0] == "Tran Peak in/s" and len(r.interval_columns) == 10
assert r.intervals == [("2025-07-02 14:55:08",
["2.430", "13", "0.940", ">100", "1.900", "5.8", "3.095", "0.001", "106.0", "51"])]
assert r.samples is None
def test_no_mic_histogram_has_seven_columns():
r = parse_xml_report_file(FIX / "R352HFZ7_530H_XML.XML")
assert r.event_units == "in/s"
assert r.channels == ["Tran", "Vert", "Long"]
assert len(r.interval_columns) == 7 and len(r.intervals[0][1]) == 7
def test_oorange_and_range_values():
r = parse_xml_report_file(FIX / "M007HVWF_K30W_XML.XML")
assert r.scalars["TranPPV"] == "OORANGE"
assert r.scalars["GeoRange"] == "1.250" and r.units["GeoRange"] == "in/s"
def test_truncated_xml_raises_valueerror():
data = (FIX / "M529L4XQ_R30H_XML.XML").read_bytes()
with pytest.raises(ValueError):
parse_xml_report(data[: len(data) // 2])
```
- [ ] **Step 3: Run them to watch them fail.**
Run: `…/python -m pytest tests/test_bw_xml_report.py -v`. Expected: FAIL on import.
- [ ] **Step 4: Implement `bw_xml_report.py`.**
- Parse with `xml.etree.ElementTree.fromstring`; wrap `ParseError` in `ValueError`.
- Walk the root's children in order.
- A child with a `<Value>` child goes in `scalars` and `units`.
- The notes are the simple children after the top-level `Units` and before
`GeoRange`.
- Waveform cells: `WaveformDataChannels/Data/Row/Cell`, one list per row,
unaltered.
- Histogram: `HistogramData/HistogramDataColumnTitle/ColumnTitle` and
`HistogramDataIntervals`, which interleaves `Time` and `Row`.
- [ ] **Step 5: Run the tests.** Expected: PASS.
- [ ] **Step 6: Commit** (fixtures with `git add -f`):
`feat(codec): parse Blastware's _XML.XML event report`
---
### Task 2: SFM's side, from the bytes alone
**Files:**
- Create: `minimateplus/decode_check.py`
- Test: `tests/test_decode_check.py`
**Interfaces:**
- Consumes: `minimateplus.event_file_io.decode_blastware_bytes`, `_GEO_NORMAL_FS_INS`, `_GEO_INT16_FS`, `_MIC_FS_PSI`; `minimateplus.waveform_codec.mic_count_to_db`.
- Produces:
```python
GEO_IPS_PER_COUNT: float = 10.0 / 32000 # from the event_file_io constants
@dataclass
class SfmSide:
event: Event
values: dict[str, object] # reference tag -> SFM's value, or absent/None = blank
notes: list[str] # non-empty project_info slots, in order
job_number: Optional[str] # None until the decoder reads it
channels: list[str] # channels with decoded data, in Tran/Vert/Long/MicL order
counts: dict[str, list[int]] # waveform samples or histogram interval peaks, per channel
def sfm_side(raw: bytes) -> SfmSide
```
The `values` keys, and the only ones SFM fills today:
- `EventType`: `"Full Waveform"` / `"Full Histogram"` from `record_type`
- `SampleRate` (int), `RecordTime` (float)
- `Pre-triggerLength`: `-pretrig_samples / sample_rate`
- `EventDate` and `EventTime` for a waveform, or `HistogramStartDate` and
`HistogramStartTime` for a histogram: `YYYY-MM-DD` and `HH:MM:SS` from
`event.timestamp`
- `TranPPV`, `VertPPV`, `LongPPV`, `PeakVectorSum` from `peak_values`
- `MicLPSPL dB(L)`: `mic_count_to_db` of the largest |MicL count|
- `MicLPSPL psi(L)`: `peak_values.micl`
- `NumberofIntervals` for a histogram: the interval count
- [ ] **Step 1: Write the failing tests:**
```python
def test_waveform_side_from_bytes():
s = sfm_side((FIX / "R352HIUI.F40W").read_bytes())
assert s.values["SampleRate"] == 1024 and s.values["RecordTime"] == pytest.approx(1.0)
assert s.values["Pre-triggerLength"] == pytest.approx(-253 / 1024)
assert (s.values["EventDate"], s.values["EventTime"]) == ("2018-07-30", "16:13:52")
assert s.notes == ["JV 241 - 1425 Spanlers Mill Rad", "Walsh Granite JV",
"Terra-Mechanics Inc- D. Harrison", "Loc #1 - 1425 Spanlers Mill Rd"]
assert len(s.counts["Tran"]) == 1277 and s.job_number is None
def test_histogram_interval_peak_in_counts():
s = sfm_side((FIX / "M529L4XQ.R30H").read_bytes())
# Blastware: Tran interval peak 2.430 in/s = 7776 counts at 10/32000 in/s per count
assert s.counts["Tran"] == [7776] and s.values["NumberofIntervals"] == 1
def test_no_filename_reaches_the_decoder():
# the type must come from bytes; today they can't tell (#41), so a histogram reads Waveform
s = sfm_side((FIX / "M529L4XQ.R30H").read_bytes())
assert s.values["EventType"] == "Full Waveform"
def test_report_fields_stay_blank():
s = sfm_side((FIX / "T1905KDW.5F0W").read_bytes())
for tag in ("TranZCFreq", "TranPeakAcceleration", "BatteryLevel", "Calibration", "TranTestResults"):
assert s.values.get(tag) is None
```
When #41 is fixed, `test_no_filename_reaches_the_decoder` is updated to
`"Full Histogram"`. Until then it pins that no name is passed.
- [ ] **Step 2: Run them; expect a FAIL on import.**
- [ ] **Step 3: Implement `sfm_side`** in `minimateplus/decode_check.py`, per the Interfaces block.
- [ ] **Step 4: Run them; expect PASS.**
- [ ] **Step 5: Commit:** `feat(codec): SFM's side of the decode check, from the event bytes alone`
---
### Task 3: The comparison
**Files:**
- Modify: `minimateplus/decode_check.py`
- Test: `tests/test_decode_check.py`
**Interfaces:**
- Consumes: `XmlReport` (Task 1), `SfmSide` (Task 2), `Carveout` (Task 4,
passed in; default `()` so this task stands alone).
- Produces:
```python
VERDICTS = ("match", "mismatch", "sfm_blank", "accepted", "no_reference", "error")
@dataclass
class FieldResult:
field: str # reference tag, or "notes", "JobNumber", "Channels",
# "samples.<ch>", "intervals.<column title>"
verdict: str
bw: Optional[str] # printed text, or "<n> cells" for a series
sfm: Optional[str] # SFM's value rendered at the printed precision
detail: str = "" # series: "rows=… differing=… row_length_disagreements=… first_diff=… max_abs=…"
carveout: Optional[str] = None
def matches_printed(value: float, printed: str) -> bool
def compare(sfm: SfmSide, ref: XmlReport, carveouts: Sequence["Carveout"] = ()) -> list[FieldResult]
```
**Rules** (exact; the tests pin each):
- **Which fields:** every tag in `ref.scalars` is compared except
`FileVersion` and `FileName`. So a field the XML carries and SFM doesn't is
automatically `sfm_blank`.
- **The reference says `N/A`:** the verdict is `no_reference`.
- **SFM has nothing (`None`):** `sfm_blank`.
- **Numbers:** for a value whose printed text begins with a number
(`-?\d+(\.\d+)?`, units after it ignored), the verdict is `match` when
`matches_printed` holds, else `mismatch`.
- **`>100`:** matches only when SFM's matching `*_zc_above_range` flag is True.
- **`OORANGE`:** a `mismatch` unless a carve-out applies.
- **Text:** anything else is compared exactly after whitespace collapse.
- **`MicLPSPL`:** compared against SFM's `MicLPSPL dB(L)` when `event_units`
contains `dB(L)`, `MicLPSPL psi(L)` when it contains `psi(L)`, otherwise
`sfm_blank`.
- **`notes`:** the list of note values vs `sfm.notes`. **`JobNumber`:**
`ref.job_number` vs `sfm.job_number` (skipped when the reference has none).
**`Channels`:** `ref.channels` vs `sfm.channels`.
- **`samples.<ch>`, one result per reference channel:**
- SFM's cells are geophone `count × GEO_IPS_PER_COUNT`; MicL uses
`mic_count_to_db(count)` for `dB(L)` or `count × _MIC_FS_PSI` for
`psi(L)`.
- For row *j*, SFM's running channels are the reference channels (in
order) with `len(sfm.counts[ch]) > j`. Their cells pair up, in order,
with the reference row's cells.
- A row whose cell count differs from SFM's running count is a row-length
disagreement for every channel in it. So are reference rows past SFM's
longest channel.
- A channel is `match` only with no row-length disagreements and every
paired cell `matches_printed`.
- `detail` always carries `rows=`, `differing=`,
`row_length_disagreements=`, `first_diff=` and `max_abs=`.
- **`intervals.<column>`, one row per column title:**
- The peak columns compare like samples: geophone `Peak in/s`, MicL
`Peak psi(L)` and `Peak dB(L)`.
- The `Freq` and `Geo PVS` columns are `sfm_blank` (SFM drops them).
- `intervals.Time` is `sfm_blank`.
- [ ] **Step 1: Write the failing tests:**
```python
def test_matches_printed_rounds_half_away():
assert matches_printed(-0.0625, "-0.063") and matches_printed(0.0015, "0.002")
assert not matches_printed(0.0026, "0.002")
def test_full_waveform_row_verdicts():
raw = (FIX / "R352HIUI.F40W").read_bytes()
res = {r.field: r for r in compare(sfm_side(raw), parse_xml_report_file(FIX / "R352HIUI_F40W_XML.XML"))}
for f in ("SampleRate", "RecordTime", "Pre-triggerLength", "EventDate", "EventTime",
"notes", "samples.Tran", "samples.Vert", "samples.Long"):
assert res[f].verdict == "match", (f, res[f])
assert res["TranZCFreq"].verdict in ("sfm_blank", "no_reference")
assert res["BatteryLevel"].verdict == "sfm_blank"
assert "FileName" not in res
def test_ragged_rows_match_by_running_channels():
# Tran/Vert/MicL end 3 samples before Long, in SFM and in Blastware's table alike
raw = (FIX / "T438HGTZ.B30W").read_bytes()
res = {r.field: r for r in compare(sfm_side(raw), parse_xml_report_file(FIX / "T438HGTZ_B30W_XML.XML"))}
for ch in ("Tran", "Vert", "Long"):
assert res[f"samples.{ch}"].verdict == "match", res[f"samples.{ch}"]
def test_an_extra_reference_row_is_a_mismatch_with_detail():
raw = (FIX / "T1905KDW.5F0W").read_bytes()
ref = parse_xml_report_file(FIX / "T1905KDW_5F0W_XML.XML")
ref.sample_rows.append(["0.000", "0.000", "0.000", "0.000"])
res = {r.field: r for r in compare(sfm_side(raw), ref)}
assert res["samples.Tran"].verdict == "mismatch"
assert "row_length_disagreements=1" in res["samples.Tran"].detail
def test_job_number_na_and_above_range():
raw = (FIX / "T1905KDW.5F0W").read_bytes()
res = {r.field: r for r in compare(sfm_side(raw), parse_xml_report_file(FIX / "T1905KDW_5F0W_XML.XML"))}
assert res["JobNumber"].verdict == "sfm_blank"
assert res["TranZCFreq"].verdict == "no_reference" # N/A
assert res["VertZCFreq"].verdict == "sfm_blank" # >100, SFM has no flag yet
def test_mic_units_pick_the_conversion():
raw = (FIX / "T004JTRF.ME0H").read_bytes() # psi(L)
res = {r.field: r for r in compare(sfm_side(raw), parse_xml_report_file(FIX / "T004JTRF_ME0H_XML.XML"))}
assert res["intervals.MicL Peak dB(L)"].verdict in ("match", "mismatch")
assert res["intervals.Tran Freq Hz"].verdict == "sfm_blank"
raw = (FIX / "R352HFZ7.530H").read_bytes() # no mic
fields = {r.field for r in compare(sfm_side(raw), parse_xml_report_file(FIX / "R352HFZ7_530H_XML.XML"))}
assert not any(f.startswith(("samples.MicL", "intervals.MicL")) for f in fields)
```
- [ ] **Step 2: Run them; expect a FAIL** (no `compare`).
- [ ] **Step 3: Implement `matches_printed` and `compare`**, per the rules.
- [ ] **Step 4: Run them; expect PASS.** If a `match` assertion fails, report
the `FieldResult` and stop. Do not loosen a rule to make it pass.
- [ ] **Step 5: Commit:** `feat(codec): compare SFM's file-only decode with Blastware's XML, field by field`
---
### Task 4: Carve-outs
**Files:**
- Create: `minimateplus/decode_check_carveouts.py`
- Modify: `minimateplus/decode_check.py` (apply carve-outs in `compare`)
- Test: `tests/test_decode_check.py`
**Interfaces:**
- Produces:
```python
@dataclass(frozen=True)
class Carveout:
id: str
fields: tuple[str, ...] # exact names, or prefixes ending in "." ("samples.")
evidence: str # why Blastware is the one that differs, and the source
applies: Callable[[SfmSide, XmlReport, FieldResult], bool]
SATURATION: Carveout
CARVEOUTS: tuple[Carveout, ...] = (SATURATION,)
```
- **How `compare` uses them:** a `mismatch` whose field a carve-out covers and
whose `applies` returns True becomes `accepted`, with `carveout=<id>`.
- **`SATURATION`:**
- Covers `TranPPV`, `VertPPV`, `LongPPV`, `PeakVectorSum`,
`samples.Tran/Vert/Long` and the `intervals.* Peak in/s` columns.
- `r = float(ref.scalars["GeoRange"])`. A cell or value Blastware printed as
`OORANGE`, or with `|bw| ≥ r − 0.0006`, is "clamped".
- It applies when every differing cell/value is clamped and SFM's is the
same sign with `r − 0.0006 ≤ |sfm| ≤ r × 1.01`.
- The upper bound keeps an 8× Sensitive-range value a mismatch.
- **`PeakVectorSum`** is a vector sum, so it can exceed the range (11.55
on `T438HGTZ`). It is accepted when Blastware printed `OORANGE` and at
least one of SFM's three PPVs sits in that ceiling band.
- Evidence text: *"Blastware clamps a clipped channel to the range maximum
and prints OORANGE; the file holds counts past full scale (32016 counts =
10.005 in/s observed). scratch/verify_against_ascii.py, 2026-08-28."*
- [ ] **Step 1: Write the failing tests:**
```python
def test_clipped_normal_range_is_accepted():
# Blastware: Tran 5.445, Vert 6.310, Long OORANGE, PVS OORANGE; SFM Long 10.005, PVS 11.55
raw = (FIX / "T438HGTZ.B30W").read_bytes()
res = {r.field: r for r in compare(sfm_side(raw), parse_xml_report_file(FIX / "T438HGTZ_B30W_XML.XML"), CARVEOUTS)}
assert res["TranPPV"].verdict == "match" and res["VertPPV"].verdict == "match"
for f in ("LongPPV", "PeakVectorSum"):
assert (res[f].verdict, res[f].carveout) == ("accepted", "saturation")
def test_sensitive_range_8x_stays_a_mismatch():
raw = (FIX / "M007HVWF.K30W").read_bytes()
res = {r.field: r for r in compare(sfm_side(raw), parse_xml_report_file(FIX / "M007HVWF_K30W_XML.XML"), CARVEOUTS)}
assert res["TranPPV"].verdict == "mismatch" and res["samples.Tran"].verdict == "mismatch"
def test_every_carveout_has_evidence():
assert all(c.id and c.fields and len(c.evidence) > 40 for c in CARVEOUTS)
```
- [ ] **Step 2: Run them; expect a FAIL.**
- [ ] **Step 3: Implement the module and the hook in `compare`.**
- [ ] **Step 4: Run all `tests/test_decode_check.py`; expect PASS.**
- [ ] **Step 5: Commit:** `feat(codec): carve-outs for proven Blastware differences -- saturation first`
---
### Task 5: The runner
**Files:**
- Create: `scratch/check_s3_decode.py`
- Test: `tests/test_check_s3_decode.py`
**Interfaces:**
- Consumes: `parse_xml_report_file`, `sfm_side`, `compare`, `CARVEOUTS`.
- Produces:
```python
def find_pairs(bin_dir: Path, xml_dir: Path) -> list[tuple[str, Path, Optional[Path]]]
# (basename, binary, xml or None); Series 3 binaries only (^[A-Z]\d{3}[0-9A-Z]{4}\.[0-9A-Z]{2}0[WH]$),
# deduped by upper-case basename; xml = <stem>_<ext>_XML.XML in xml_dir
def event_attrs(name: str, ref: XmlReport, raw: bytes) -> dict[str, str]
# grouping keys, all from the reference or the file:
# model ("MiniMate Plus" / "BlastMate III" from Version), serial (SerialNumber),
# type (EventType), year (EventDate or HistogramStartDate), sample_rate, range (GeoRange),
# mic_units (event_units), interval (IntervalSize or "-"),
# setup_standard ("yes" if b"Standard Recording Setup" in raw else "no")
def check_event(name: str, bin_path: str, xml_path: Optional[str]) -> dict
# {"file", "attrs", "results": [[field, verdict, bw, sfm, detail, carveout], ...]}
# no xml -> one ["event","no_reference",…] row; any exception -> one ["event","error",None,None,repr(exc),None] row
def main(argv: Optional[list[str]] = None) -> int
```
- **CLI:** `bin_dir xml_dir [--out DIR] [--serial S]... [--year Y]...
[--type W|H] [--field PREFIX]... [--sample N] [--seed K] [--jobs N]
[--file NAME] [--compare-to DIR]`.
- `--field` keeps only result rows whose field starts with a given prefix
(the spec's "field group" partial run).
- `--file` and `--compare-to` are wired in Task 7; here they are only
accepted.
- The spec's "decoder path" grouping key is omitted: the decoder does not
expose it today.
- **Output:** writes `<out>/results.jsonl.gz` (one line per event) and
`<out>/run.json`.
- `run.json` holds the args, the `git rev-parse HEAD`, the event count and
the wall time.
- It prints the run folder.
- Parallelism: `ProcessPoolExecutor(jobs).map(…, chunksize=64)`.
- [ ] **Step 1: Write the failing tests** (on the fixture folder, which holds
binaries and XMLs together):
```python
def test_find_pairs_dedupes_and_pairs(tmp_path):
(tmp_path / "Sent").mkdir()
for n in ("R352HIUI.F40W", "Sent/R352HIUI.F40W", "UM11719_20240404193109.IDFH"):
(tmp_path / n).write_bytes(b"x")
pairs = find_pairs(tmp_path, FIX)
assert [p[0] for p in pairs] == ["R352HIUI.F40W"] and pairs[0][2].name == "R352HIUI_F40W_XML.XML"
def test_check_event_rows_and_attrs():
out = check_event("M007HVWF.K30W", str(FIX / "M007HVWF.K30W"), str(FIX / "M007HVWF_K30W_XML.XML"))
assert out["attrs"]["range"] == "1.250" and out["attrs"]["model"] == "MiniMate Plus"
assert any(r[0] == "TranPPV" and r[1] == "mismatch" for r in out["results"])
def test_bad_input_is_one_error_row(tmp_path):
bad = tmp_path / "R352HIUI.F40W"; bad.write_bytes(b"not a blastware file")
out = check_event(bad.name, str(bad), str(FIX / "R352HIUI_F40W_XML.XML"))
assert out["results"] == [["event", "error", None, None, out["results"][0][4], None]]
def test_cli_writes_results(tmp_path):
assert main([str(FIX), str(FIX), "--out", str(tmp_path / "run"), "--jobs", "1"]) == 0
lines = gzip.open(tmp_path / "run/results.jsonl.gz", "rt").read().splitlines()
assert len(lines) == 7 and json.loads((tmp_path / "run/run.json").read_text())["events"] == 7
```
- [ ] **Step 2: Run them; expect a FAIL.**
- [ ] **Step 3: Implement**, per the Interfaces block.
- [ ] **Step 4: Run them; expect PASS.**
- [ ] **Step 5: Time a sample.** Run `scratch/check_s3_decode.py
~/dl2-archive/files ~/dl2-archive/xml --sample 2000 --jobs 4`. Expected: a
few minutes. Note the time in the commit body.
- [ ] **Step 6: Commit:** `tooling(scratch): run the decode check over the archive in parallel`
---
### Task 6: The summary and the detailed report
**Files:**
- Create: `scratch/decode_check_report.py`
- Modify: `scratch/check_s3_decode.py` (write both reports at the end of a run)
- Test: `tests/test_check_s3_decode.py`
**Interfaces:**
- Produces:
```python
def aggregate(results_path: Path) -> dict
def write_summary(agg: dict, path: Path) -> None # <out>/summary.md, for Brian
def write_details(agg: dict, path: Path) -> None # <out>/details.json, for Claude
```
- **`summary.md`** has four parts:
- a per-field table with one column per verdict (in `VERDICTS` order),
sorted by non-match count
- a line `N of M fields fully matching`
- the non-match counts per event year
- the carve-out counts
- **`details.json`** has one entry per `(field, verdict)` with verdict ≠
`match`. Each entry holds:
- `total`
- `groups`: for each attribute, the values whose failing count is ≥ 10% of
`total`. Each value carries `{value, failing, compared, rate}`, where
`compared` counts events where the field's verdict was not
`no_reference`. Sorted by `failing` descending; `concentrated: true` when
`rate ≥ 0.95`.
- `examples`: up to 8, taking one per top group value first. Each gives
`{file, bw, sfm, detail, rerun}` with `rerun = "python
scratch/check_s3_decode.py <bin_dir> <xml_dir> --file <name>"`.
- [ ] **Step 1: Write the failing tests:** build a small `results.jsonl.gz` by
hand with literal rows: 3 events, one field `SampleRate`, two `mismatch` on
`sample_rate=2048`, one `match` on `1024`. Assert:
- `details.json["SampleRate|mismatch"]["groups"]["sample_rate"]` is
`[{"value": "2048", "failing": 2, "compared": 2, "rate": 1.0,
"concentrated": True}]`
- `summary.md` contains `0 of 1 fields fully matching`
- every example carries a `rerun` with `--file`
- [ ] **Step 2: Run them; expect a FAIL.**
- [ ] **Step 3: Implement**, streaming the results file line by line and
holding only counters plus a capped example list.
- [ ] **Step 4: Run them; expect PASS.**
- [ ] **Step 5: Commit:** `tooling(scratch): decode-check summary and grouped detail report`
---
### Task 7: Run-to-run changes and the single-event view
**Files:**
- Modify: `scratch/decode_check_report.py`, `scratch/check_s3_decode.py`
- Test: `tests/test_check_s3_decode.py`
**Interfaces:**
- Produces:
```python
def compare_runs(prev_results: Path, cur_results: Path) -> dict
# {"fields": {field: {verdict: [before, after]}},
# "regressions": [{"file", "field", "before", "after"}], # before == "match", after != "match"
# "fixed": int} # before != "match", after == "match"
def write_changes(chg: dict, path: Path) -> None # <out>/changes.md, regressions first
```
- **`--compare-to DIR`:** defaults to the newest other folder in the runs
folder. `summary.md` starts with a regressions line (`0 regressions` or the
count plus a pointer to `changes.md`).
- **`--file NAME`:** finds that one event, runs `check_event` and prints a
table `field | verdict | Blastware | SFM | detail` to stdout. No run folder
is written.
- [ ] **Step 1: Write the failing tests:**
- Two hand-built results files where one `(file, field)` goes from `match`
to `mismatch` and another from `sfm_blank` to `match`: assert one
regression and `fixed == 1`.
- `main([FIX, FIX, "--file", "M007HVWF.K30W"])` prints a line containing
`TranPPV` and `mismatch`, and returns 0.
- [ ] **Step 2: Run them; expect a FAIL.**
- [ ] **Step 3: Implement.**
- [ ] **Step 4: Run them; expect PASS.**
- [ ] **Step 5: Commit:** `tooling(scratch): decode-check run-to-run changes and a one-event view`
---
### Task 8: The first full run, checked against what we know
**Files:**
- Delete: `scratch/verify_bw_fields_against_xml.py` (the checker replaces it)
- Modify: `CLAUDE.md` ("Where things stand": one short bullet with the first
run's headline numbers and the command)
- Modify: `docs/instantel_protocol_reference.md`. Correct the `#53` note in
place, per the retraction convention: the three files pick an earlier,
false footer, get the right sample count and a time 4 s off, and log no
`decode_problems`. ⚠ The file is CRLF, so edit it with the Edit tool, not a
Python text-mode rewrite.
- [ ] **Step 1: Full run.** `scratch/check_s3_decode.py ~/dl2-archive/files
~/dl2-archive/xml --jobs 4`. Expected: it finishes in under an hour and
writes `summary.md`, `details.json` and `results.jsonl.gz`.
- [ ] **Step 2: Check the first-run expectations from the spec's "What success
looks like"**, one by one, against `summary.md` and `details.json`:
- `SampleRate`, `RecordTime`, `Pre-triggerLength` and `notes` all `match`
- `samples.*` mismatch only on the range-1.250 events (8×) among 2025–26
events; `T438HGTZ.B30W` matches
- `EventType` mismatches exactly on the histograms
- `JobNumber` and the calculated fields are `sfm_blank`
- the three `#53` files show as time mismatches
Any other non-match is a finding. Write it into the report's notes for
Brian; **do not change a rule to hide it.** If an expectation fails because
the checker is wrong, fix the checker with a test first.
- [ ] **Step 3: Full suite.** Expected: no new failures beyond the 18 known.
- [ ] **Step 4: Docs, per Files above.**
- [ ] **Step 5: Commit:** `docs: the decode checker's first full run; correct the #53 note`
@@ -1,172 +0,0 @@
# SFM 1c bench fixes, Batch 1 — Implementation Plan
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** Fix the three reliability findings from the 2026-10-29 bench that put wrong or missing data in front of a user: MiniMate settings read from escaped bytes (#1), a MiniMate start reported failed because the read-back did not survive a dropped modem line (#9), and MiniMate downloads stored without the file reader (#8).
**Architecture:** Three independent fixes on `feat/series4-sfm-parity` (merged up with `dev` at `342c696`), each behind its own tests on recorded BE9441 bytes. #1 changes only the four anchor-relative fields of the live `SUB 1A` decode; #9 adds one guarded reconnect to the Series-3 start read-back; #8 stores Series-3 downloads through the same Blastware-file import path production uses (`WaveformStore.save_imported_bw`), the way Series 4 already uses `save_imported_idf`.
**Tech Stack:** Python 3.10, pytest; `minimateplus` (client, framing, blastware_file), `sfm` (device_access, event_ingest, waveform_store).
**Spec:** `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` → *Left open by the 1c bench (2026-10-29)*, items 1, 8, 9 (and 15, retracted below).
## Global Constraints
- Branch `feat/series4-sfm-parity` only; push each commit; never `main`; no `CHANGELOG.md` edits (feature branch).
- **Reliability before speed** (Brian, 2026-10-29): no change removes a check; a start/stop is still sent exactly once, never retried.
- **File boundary with the S3 decode-checker session:** do not edit `minimateplus/event_file_io.py`, `histogram_codec.py`, `waveform_codec.py`, `bw_xml_report.py`, `decode_check*.py`.
- `docs/instantel_protocol_reference.md` is CRLF: edit it with the Edit tool only.
- Tests: `/home/serversdown/seismo-relay/.venv/bin/python -m pytest -q -p no:cacheprovider`; the baseline is exactly 16 known failures (15 `test_bw_ascii_report.py`, `test_event_file_io.py::test_save_imported_bw_without_report_works_unchanged`).
- Store consequence (state it in the commit and docs): #8 changes how **new** live downloads are stored; existing rows and files are untouched; no backfill, no migration.
## Review Focus
1. A modem that closes the line cleanly (FIN) during the read-back shows as silence, not an `OSError`: no reconnect, the result stays "sent, not checked", nothing re-sent. (Task 2 test.)
2. A MiniMate on a serial cable: never reconnect in the read-back — opening its port reboots the unit (measured 2026-10-25). (Task 2 test.)
3. A settings read while the unit is monitoring returns the device-info block, not the settings block (measured 2026-10-29): mode, sample rate, interval and record time must come back `None`, not garbage. (Task 1 test.)
4. Downloading an event twice, or one the watcher already imported, must not add a second row. (Task 3 tests.)
5. The channel block (trigger level, range, scale) and the note strings must read exactly as before: only the four anchor fields move to unescaped bytes. (Task 1 test.)
## Retraction carried by this plan
**#15 is not a bug.** `device_commands.sent` is documented as `1 acknowledged, 0 nothing sent, NULL unknown` (`sfm/database.py:148`, `change.py:12-14`); a stop answered by a ring instead of its ack is exactly "unknown", and the row's `error` text already says the frame was sent. Task 4 retracts it in the spec.
---
### Task 1: The live settings decode reads its four anchor fields from unescaped bytes (#1)
**Files:**
- Modify: `minimateplus/client.py` — `_decode_compliance_config_into` (~line 2312), its anchor block (~2385–2440)
- Create: `tests/test_s3_compliance_anchor_fields.py`
**Interfaces:** Produces nothing new; `_decode_compliance_config_into(data: bytes, info: DeviceInfo) -> None` keeps its signature. `info.compliance_config` fields `recording_mode`, `sample_rate`, `histogram_interval_sec`, `record_time` change meaning only for escaped replies.
Measured layout once escapes are removed (`framing.unescape_reply`), from every distinct recorded reply: **mode `anchor−7` (u8), sample rate `anchor−6` (u16 BE), histogram interval `anchor−4` (u16 BE, s), record time `anchor+6` (f32 BE)**. The channel block and strings are correct on the raw bytes and must stay there (unescaped, `"Tran"+28` reads 0.0 instead of 6.2061).
- [ ] **Step 1: Write the failing tests** — a helper collects every `SUB 0xE5` frame from `tests/fixtures/minimate-bench-10-25-26/*_rx.bin` and `tests/fixtures/minimate-bench-10-26-26-histogram/unit_replies.bin` whose `data` contains the anchor, de-duplicated by the 18 bytes around it (`S3FrameParser().feed`).
```python
@pytest.mark.parametrize("fixture,expect", [ # (mode, sample_rate, interval_s, record_time_s)
("10-25", (1, 4096, 5, 5.0)), # Continuous
("10-26a", (4, 2048, 2, 20.0)), # Histogram + Continuous
("10-26b", (3, 4096, 900, 20.0)), # Blastware's 16:26 write: Histogram, 15 min
("10-26c", (3, 4096, 2, 20.0)), # Blastware's 16:27 write: back to 2 s (tonight's unit)
])
def test_anchor_fields_read_from_unescaped_bytes(fixture, expect): ...
# decode the frame's data with _decode_compliance_config_into(DeviceInfo())
# assert (cc.recording_mode, cc.sample_rate, cc.histogram_interval_sec, round(cc.record_time, 2)) == expect
def test_channel_block_still_reads_from_raw_bytes():
# data = the 10-26c frame-B data + the next E5 frame whose data contains b"Tran"
# assert cc.trigger_level_geo == pytest.approx(0.04, abs=1e-4)
# assert cc.geo_adc_scale == pytest.approx(6.2061, abs=1e-3) and cc.geo_range == 0
def test_a_reply_without_the_settings_block_reads_as_unknown():
# the recorded SUB 0xFE (device info) reply data -- what a monitoring BE9441 returned for 1A
# assert all four anchor fields are None
```
The fixture labels are the test's own: number the de-duplicated replies in file order and map them to the four expectations above (assert there are exactly four).
- [ ] **Step 2: Run** `…pytest -q tests/test_s3_compliance_anchor_fields.py` → FAIL: `10-25` reads mode 0, `10-26c` reads sample rate 0 and interval 4098 (today's decoder on escaped bytes).
- [ ] **Step 3: Implement** — in the anchor block, search `_ANCHOR` in `logical = unescape_reply(data)` (same `0:150` window) and read the four fields from `logical` at the offsets above; leave every other read on `data`. Update the layout comment to the measured logical layout and note the old "anchor−7 constant 0x10" was the escape before `04` at 1024 sps.
- [ ] **Step 4: Run** the new tests, then the full suite → only the 16 known failures.
- [ ] **Step 5: Commit** `fix(minimateplus): read a MiniMate's mode, sample rate, interval and record time after removing escapes (#1)`.
### Task 2: The Series-3 start read-back reconnects once after a dropped line (#9)
**Files:**
- Modify: `sfm/device_access/s3.py` — `change_monitoring`'s `read_state` (~line 230)
- Modify: `tests/device_access_fakes.py` — `FakeMiniMateClient`: add `read_serial()` (returns `serial_reported`, default the unit's serial; records `"read_serial"`) and `wake_errors=` (exceptions raised by successive `wake()` calls)
- Test: `tests/test_device_access_change.py`
**Interfaces:** Consumes `MiniMateClient.read_serial()` (exists), `normalise_serial` (`sfm/device_access/series.py`). No new public names.
Behaviour: in `read_state`, an `OSError` from `_woken_state(client)` (Broken pipe / reset / aborted — measured: `[Errno 32] Broken pipe` at BE9441's first wake after the sensor check) **on a TCP address, the first time only**: log a warning "the line dropped during the read-back — reconnecting to read the state (nothing is re-sent)", `client.close()`, `client.open()`, require `normalise_serial(client.read_serial()) == serial` (else raise `WrongUnit`), then `_woken_state(client)`. A second `OSError`, any other error, or a serial-cable address propagates as today.
- [ ] **Step 1: Write the failing tests**
```python
def test_series3_start_read_back_reconnects_after_a_dropped_line():
fake = FakeMiniMateClient(monitor_states=[False, True], wake_errors=[BrokenPipeError(32, "Broken pipe")])
r = access3(fake).start_monitoring(TCP3, "BE18193")
assert (r.outcome, r.verified, r.state_after) == ("sent", "ok", "monitoring")
assert fake.writes == ["start_monitoring"] and fake.opened == 2 and "read_serial" in fake.calls
def test_series3_read_back_reconnects_only_once():
fake = FakeMiniMateClient(monitor_states=[False], wake_errors=[BrokenPipeError(32, "x")] * 2)
with pytest.raises(ChangeUnconfirmed): access3(fake).start_monitoring(TCP3, "BE18193")
assert fake.writes == ["start_monitoring"] and fake.opened == 2
def test_series3_read_back_reconnect_refuses_a_different_unit():
fake = FakeMiniMateClient(monitor_states=[False], wake_errors=[BrokenPipeError(32, "x")], serial_reported="BE11529")
with pytest.raises(ChangeUnconfirmed) as e: access3(fake).start_monitoring(TCP3, "BE18193")
assert e.value.http_status == 409 and fake.writes == ["start_monitoring"]
def test_series3_read_back_does_not_reconnect_on_a_serial_cable():
# address with port=, no host: opening a MiniMate's port reboots it
... assert fake.opened == 1 and raises ChangeUnconfirmed
def test_series3_read_back_silence_is_not_a_dropped_line():
fake = FakeMiniMateClient(monitor_states=[False], wake_errors=[NoAnswer("quiet")])
... raises ChangeUnconfirmed; fake.opened == 1; writes == ["start_monitoring"]
```
(`serial_reported` applies to `read_serial()` only; `connect()` keeps returning the real serial so the pre-send identity check passes. Use the module's existing `access3`, `TCP3` helpers; add a serial-cable `UnitAddress` beside `TCP3`.)
- [ ] **Step 2: Run** them → the reconnect tests FAIL (no reconnect today); the last two may already pass — keep them as guards.
- [ ] **Step 3: Implement** `read_state` as described (a closed-over `reconnected` flag).
- [ ] **Step 4: Run** `tests/test_device_access_change.py`, then the full suite → only the 16 known failures.
- [ ] **Step 5: Commit** `fix(sfm): a MiniMate start's read-back reconnects once when the modem dropped the line (#9)`.
### Task 3: MiniMate downloads are stored through the Blastware-file import path (#8)
**Files:**
- Modify: `minimateplus/blastware_file.py` — add `blastware_file_bytes(event: Event, a5_frames: list) -> bytes`; `write_blastware_file` writes its result (no behaviour change)
- Modify: `sfm/device_access/models.py` — `DownloadedEvent.bw_bytes: Optional[bytes] = field(default=None, repr=False)` (Series 3: the assembled Blastware file)
- Modify: `sfm/device_access/s3.py` — `download_event` fills `bw_bytes` from the verified event's frames
- Modify: `sfm/waveform_store.py` — `save_imported_bw(..., source_kind: str = "bw-import")` writes it into the sidecar's `source.kind`
- Modify: `sfm/event_ingest.py` — `persist_download`'s Series-3 branch
- Test: `tests/test_event_ingest.py`, `tests/test_5a_blastware_walk_histogram.py`
**Interfaces:** Produces `blastware_file_bytes(event, a5_frames) -> bytes`; `DownloadedEvent.bw_bytes`; `save_imported_bw(bw_bytes, source_path, *, serial_hint=None, bw_report_text=None, source_kind="bw-import") -> tuple[Event, dict]`.
Behaviour: Series 3 mirrors Series 4 — `ev, rec = store.save_imported_bw(dl.bw_bytes, source_path=Path(dl.filename), serial_hint=dl.serial, source_kind="sfm-live")`, then the existing `db.insert_events(...)`. No `backfill_series3_event` on this path (the file's setup block supplies sample rate and record time, #44/#45); no overlay of the live `0C` peaks (data comes from the binary — they stay the download *check*). A download with no `bw_bytes` raises `IngestError("…the download carried no event file; nothing was stored")`. The "Waveform" label on a live histogram stays until the checker session's #41 (record type from `STRT[18]`) lands on `dev`.
- [ ] **Step 1: Write the failing tests**
```python
# tests/test_5a_blastware_walk_histogram.py, beside the existing K441LTON.900 comparison:
def test_blastware_file_bytes_is_blastwares_file():
# the walk's frames for key 0111f210 -> blastware_file_bytes(ev, frames) == (FIX/"blastware"/"K441LTON.900").read_bytes()
# tests/test_event_ingest.py
def test_a_series3_histogram_download_is_stored_from_its_file(tmp_path):
bw = (HIST_FIX / "K441LTON.900").read_bytes() # byte-identical to SFM's download (sha f10f39a8…)
out = persist_download(DownloadedEvent(event_id="BE9441:0111f210:20261026170036", serial="BE9441",
series=3, filename="K441LTON.900", verified=None, bw_bytes=bw,
timestamp=datetime.datetime(2026, 10, 26, 17, 0, 36)), store=WaveformStore(tmp_path / "w"), db=SeismoDb(tmp_path / "s.db"))
# assert the stored file's sha256 == hashlib.sha256(bw).hexdigest()
# assert plot_json_from_hdf5(<h5>)["channels"]["Tran"]["values"] (non-empty: the histogram decoded)
# assert the sidecar's source.kind == "sfm-live" and the row's sample_rate == 4096
def test_the_small_mic_off_histogram_is_stored_with_samples(tmp_path): # K441LTOK.QZ0, refused on 10-29
def test_a_repeat_series3_download_adds_no_row(tmp_path): # persist twice: one row; second inserted False
def test_a_series3_download_with_no_file_stores_nothing_and_says_so(tmp_path) # replaces the no-event test
```
Rewrite `test_a_series3_event_is_backfilled_then_stored_as_series3` to the new contract (bytes in, `save_imported_bw` called with `source_kind="sfm-live"`, no backfill); keep `test_downloading_an_event_the_watcher_stored_writes_nothing_series3` passing unchanged.
- [ ] **Step 2: Run** them → FAIL (`bw_bytes` / `blastware_file_bytes` / `source_kind` do not exist).
- [ ] **Step 3: Implement** the five file changes above.
- [ ] **Step 4: Run** `tests/test_event_ingest.py tests/test_5a_blastware_walk_histogram.py tests/test_device_access_events.py tests/test_server_device_access.py`, then the full suite → only the 16 known failures.
- [ ] **Step 5: Commit** `fix(sfm): store a MiniMate download through the Blastware-file import path, as production does (#8)` — body states: new live downloads only; existing rows untouched; no backfill or migration.
### Task 4: Docs
**Files:** the spec (*Left open by the 1c bench*), `docs/instantel_protocol_reference.md` (CRLF — Edit tool), `CLAUDE.md` ("Where things stand").
- [ ] **Step 1:** Spec: mark #1, #8, #9 fixed (commit ids); **retract #15 in place** (by design: `sent` NULL = sent without acknowledgement); #2 fixed by the `dev` merge (`342c696`).
- [ ] **Step 2:** Instantel reference, a dated change-log row + §7.6.1 note: the measured logical `1A` layout (mode −7, rate −6, interval −4, record time +6 after unescaping; the old "anchor−7 constant 0x10" was the escape before `04`); while monitoring, BE9441 answered the `1A` reads with its device-info block (measured 2026-10-29); the channel block is read on raw bytes, so a trigger/alarm float containing `02/03/04/10` would read shifted — open, unmeasured.
- [ ] **Step 3:** CLAUDE.md: one line under the 1c entry — Batch 1 done (#1, #8, #9), #15 retracted.
- [ ] **Step 4: Commit** `docs: 1c bench Batch 1 -- #1, #8, #9 fixed; #15 retracted; the 1A layout after unescaping`.
@@ -1,245 +0,0 @@
# Phase 4 — Call-home enable/disable Implementation Plan
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** Turn a unit's automatic call-home on or off from SFM, for both series, through the audited change path start/stop already uses: identity check → audit → one send → read back → audit.
**Architecture:** `run_change` (`sfm/device_access/change.py`) becomes kind-agnostic: a `ChangeKind` says what the change is called and which state means it took. Each series supplies a call-home state read (`"enabled"` / `"disabled"`, plus Series 4's `"calling_home"`) and a send built from the block it read moments before. Series 4 sends `micromate.writes.plan_call_home_enabled` (frames already equal to THOR's). Series 3 patches byte 5 of the unescaped `0x2C` image and sends it through the existing `0x7E`/`0x7F` path. A gate keeps that send refused until its frame is reproduced from a Blastware capture. New serial-keyed routes, and the page's Call Home tab by serial gets On/Off buttons.
**Tech Stack:** Python 3 / FastAPI (SFM), pytest; page JS in `sfm/static/` tested with Node.
**Spec:** `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` — row 9 of the job table, "The safety layer" (tiers, read-back: "call-home → re-read `0x2C` and compare the edited bytes"), the per-operation table (`call-home enable/disable | read 0x2C → 0x7E (126 B content, offset 0x007E) → 0x7F | re-read 0x2C`), build phase 4.
## Global Constraints
- Branch `feat/series4-sfm-parity`, worktree `~/seismo-relay-parity`. Never commit to `main`. Push every commit. No `CHANGELOG.md` edits (written on `dev` at merge).
- **No live write without Brian's explicit go, per send.** Dry runs and tests only, until the bench task.
- A write is never retried (`DeviceAccess._dispatch(change=True)`); never send `0xA2`; never write modem baud or modem type.
- File boundary with the decode-checker session: do not edit `minimateplus/event_file_io.py`, `histogram_codec.py`, `waveform_codec.py`, `bw_xml_report.py`, `decode_check*.py`.
- No inline JavaScript: new page logic goes in `sfm/static/device_routing.js` (DOM-free, Node-tested); `sfm/static/sfm_webapp.js` only applies it (stack-wide rule, 2026-11-02).
- Series 4: read-modify-write. Send back every byte of the block as read except bit 0 of `content[5]`. Never synthesise or zero `content[118:120]` (unit-maintained; it changes after a config write).
- Series 3: read the enable byte from the **unescaped** block (the lesson of bench finding #1). `0x00` off, `0x01` on (measured April 2026, BE11529). Any other value is `unknown(0xNN)` and nothing is sent.
- Speed is secondary to reliability: no new round trips beyond the reads the change needs.
- Test command: `/home/serversdown/seismo-relay/.venv/bin/python -m pytest -q -p no:cacheprovider`. Baseline: exactly 16 known failures (15 in `tests/test_bw_ascii_report.py`, `tests/test_event_file_io.py::test_save_imported_bw_without_report_works_unchanged`). Read the failure list before committing.
## Review Focus
1. A change requested while a Micromate is calling home (run state `0x03`) → 503, nothing sent, the line released (the existing `CallHomeInProgress` path).
2. A MiniMate whose unescaped byte 5 is neither `0x00` nor `0x01` → state `unknown(0xNN)`: a dry run still shows it, a live change sends nothing (`UnitStateUnknown`, 409).
3. A read-back where other bytes changed (Series 4 `[118:120]` always does) → verified on the edited bit alone; the changed offsets are recorded in the result and the audit row, never a mismatch.
4. Already in the requested state → skipped with no send, unless `even_if_already` (the bench's no-op write is exactly that experiment).
5. A live Series-3 call-home change before its frame has been reproduced from a Blastware capture → 501 before any connection. A dry run works.
---
### Task 1: `run_change` takes a `ChangeKind`
**Files:**
- Modify: `sfm/device_access/change.py` (signature and the three derived names at the top of `run_change`; the finish paths that build `detail` and `states`)
- Modify: `sfm/device_access/s3.py` (`change_monitoring`), `sfm/device_access/s4.py` (`s4_change_monitoring`) — call sites only
- Test: `tests/test_device_access_change_kind.py` (new)
**Interfaces:**
- Produces:
- `@dataclass(frozen=True) class ChangeKind: action: str; want: str; became: str` in `change.py`.
- `monitoring_change(start: bool) -> ChangeKind` gives exactly today's values: `("start monitoring", "monitoring", "started")` / `("stop monitoring", "idle", "stopped")`.
- `call_home_change(enabled: bool) -> ChangeKind` gives `("enable call-home", "enabled", "enabled")` / `("disable call-home", "disabled", "disabled")`.
- `run_change(*, kind: ChangeKind, serial, series, dry_run, even_if_already, audit, address, caller, sleep, verify_timeout_s, verify_interval_s, read_serial, read_state, describe_plan, send, is_refusal=_never, is_ring=_never, pre_send=None, snapshot: Optional[Callable[[], Dict[str, Any]]] = None) -> ChangeResult`. `start` is gone.
- `snapshot`: called once, after the read-back loop, on the two normal finish paths (verified `ok` or `mismatch`). Its dict goes in `detail["snapshot"]` and the audit row's `states["snapshot"]`. A snapshot that raises is recorded as `{"error": str(exc)}` and does not change the outcome.
- [ ] **Step 1: Write the failing tests** (fake callables, no device, the `Audit` fake pattern from `tests/test_device_access_change.py`):
- `test_monitoring_kinds_are_todays_names`: `monitoring_change(True) == ChangeKind("start monitoring", "monitoring", "started")`, and likewise for stop.
- `test_a_call_home_change_is_verified_by_its_own_state`: `kind=call_home_change(False)`, states `["enabled", "disabled"]` → `(outcome, verified, state_after) == ("sent", "ok", "disabled")`, and `result.action == "disable call-home"`.
- `test_a_call_home_read_back_that_did_not_change_is_a_mismatch`: states `["enabled", "enabled", "enabled", "enabled"]` with verify `(3.0, 1.0)` → `("failed", "mismatch")`.
- `test_the_snapshot_is_kept_in_the_result_and_the_audit`: `snapshot=lambda: {"after": "ab"}` → `result.detail["snapshot"] == {"after": "ab"}` and the audit row's `states["snapshot"] == {"after": "ab"}`.
- `test_a_failing_snapshot_does_not_change_the_outcome`: a snapshot raising `RuntimeError("x")` → still `("sent", "ok")`, `detail["snapshot"] == {"error": "x"}`.
- [ ] **Step 2: Run** `pytest tests/test_device_access_change_kind.py -v`. Expected: FAIL (`ImportError: cannot import name 'ChangeKind'`).
- [ ] **Step 3: Implement.** Replace `start` with `kind` in `run_change`, deriving `action`, `want` and `became` from `kind`. Add the snapshot as specified. Update the two call sites to `kind=monitoring_change(start)`, keeping their own `start` parameter.
- [ ] **Step 4: Run** the new file plus `tests/test_device_access_change.py tests/test_device_access_s3_events.py tests/test_server_device_access.py`. Expected: all pass, with the existing start/stop tests unchanged.
- [ ] **Step 5: Commit** `refactor(sfm): run_change takes a ChangeKind -- start/stop unchanged, call-home next (phase 4)`.
### Task 2: Series 4 — read call-home, change it
**Files:**
- Modify: `micromate/opcodes.py` (`ENABLEABLE_WRITES`), `micromate/client.py` (new method)
- Modify: `sfm/device_access/models.py` (new `CallHomeState`), `sfm/device_access/s4.py` (two new functions)
- Modify: `tests/device_access_fakes.py` (`FakeMicromateClient` call-home support), `tests/test_micromate_execute.py:37` (the ceiling assertion)
- Test: `tests/test_device_access_s4_call_home.py` (new)
**Interfaces:**
- Consumes: Task 1's `ChangeKind`, `call_home_change`, `run_change(snapshot=…)`.
- Produces:
- `ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F})`.
- `MicromateClient.get_call_home_content() -> bytes`: the 126-byte content, `_content(self.protocol.read_call_home_config())`.
- `@dataclass class CallHomeState: serial: str; series: int; enabled: Optional[bool]; dial_string: Optional[str]; detail: Dict[str, Any]` (`detail["byte5"]` as `"0xNN"`, `detail["block"]` as hex).
- `s4_call_home_state(client, serial) -> CallHomeState`: enabled is bit 0 of `content[5]`; the dial string is `content[6:46]` up to its first NUL, decoded as ASCII.
- `s4_change_call_home(client, serial, *, enabled, dry_run, even_if_already, audit, address, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`:
- `read_state` returns `"calling_home"` when `client.read_run_state().name == "calling_home"`, else `"enabled"` / `"disabled"` from `content[5] & 1`. It keeps the last content it read.
- `describe_plan`: `plan_call_home_enabled(last_content, enabled).describe()`, so the plan is built from the read `run_change` made just before.
- `send` executes that same plan object.
- `snapshot` returns `{"before": hex, "after": hex, "changed_offsets": [...]}`, comparing the first and last content read.
- `pre_send`, `is_refusal` and `is_ring` are as in `s4_change_monitoring`.
- [ ] **Step 1: Fake support.**
- `FakeMicromateClient(call_home=<126-byte content>)`, defaulting to UM12947's enabled read from `tests/fixtures/micromate-writes` (the reads `tests/test_micromate_writes.py::_call_home_reads` uses), plus a `read_call_home_config()` on `_FakeProtocol` returning `bytes(11) + content`.
- `execute(plan)` applies a `0x7E` step's data as the new content, then replaces `[118:120]` with its bitwise complement, mimicking the unit-maintained field (the default read already holds `2e 5e`, so a fixed value would not change it).
- [ ] **Step 2: Write the failing tests:**
- `test_s4_call_home_state_reads_the_enable_bit_and_dial_string`: on the default content (UM12947, `[5] = 0x05`) → `enabled is True`, `dial_string == "RADIO RING"`, `detail["byte5"] == "0x05"`.
- `test_s4_dry_run_shows_thors_frames`: dry run `enabled=False` → `result.plan` frames equal `plan_call_home_enabled(content, False).describe()["steps"]` frames, and `fake.executed == []`.
- `test_s4_disable_sends_7e_7f_and_verifies`: live `enabled=False` → `("sent", "ok", "disabled")`; executed plan subs `[0x7E, 0x7F]`.
- `test_s4_unit_maintained_bytes_do_not_make_a_mismatch`: same run → `verified == "ok"` and `detail["snapshot"]["changed_offsets"] == [5, 118, 119]`.
- `test_s4_no_change_while_calling_home`: `run_states=[0x03]` → `CallHomeInProgress`, nothing executed.
- `test_s4_already_enabled_is_skipped`: `enabled=True` on enabled content → `outcome == "skipped"`, nothing executed. With `even_if_already=True` → executed once, and the plan carries the "changes nothing" warning.
- Update `test_micromate_execute.py:37` to the new four-SUB set.
- [ ] **Step 3: Run** the new file. Expected: FAIL (`ImportError: s4_call_home_state`).
- [ ] **Step 4: Implement** as specified in Interfaces.
- [ ] **Step 5: Run** the new file plus `tests/test_micromate_execute.py tests/test_micromate_writes.py tests/test_device_access_change.py`. Expected: pass.
- [ ] **Step 6: Commit** `feat(sfm): Series-4 call-home state and audited enable/disable (phase 4)`.
### Task 3: Series 3 — read call-home, change it (live send gated)
**Files:**
- Modify: `minimateplus/protocol.py` (two pure functions next to `write_image`), `minimateplus/client.py` (two methods)
- Modify: `sfm/device_access/s3.py` (gate constant + two adapter methods)
- Modify: `tests/device_access_fakes.py` (`FakeMiniMateClient` call-home support)
- Test: `tests/test_s3_call_home.py` (new)
**Interfaces:**
- Consumes: Task 1, and Task 2's `CallHomeState`.
- Produces:
- `call_home_enabled(raw: bytes) -> Optional[bool]` in `minimateplus/protocol.py`: `unescape_reply(raw)[5]`, `0x01` → True, `0x00` → False, else None.
- `call_home_image(raw: bytes, enabled: bool) -> bytes`: `write_image(SUB_CALL_HOME_WRITE, raw)` with byte 5 set to `0x01`/`0x00` and every other byte unchanged. Raises `ValueError` when the image's byte 5 is not `0x00`/`0x01`.
- `MiniMateClient.read_call_home_raw() -> bytes` (the protocol's `read_call_home_config()`) and `MiniMateClient.write_call_home_image(image: bytes) -> None` (the protocol's `write_call_home_config(image)`: `0x7E` then `0x7F`, each ack checked).
- `S3_CALL_HOME_FRAME_VERIFIED = False` in `sfm/device_access/s3.py`. Task 4 flips it.
- `Series3Adapter.call_home_state(address, serial) -> CallHomeState`: `wake`, then `read_call_home_raw()`. The dial string is the unescaped `[6:46]` up to its first NUL. `detail` carries `byte5`, `block` (raw hex) and `serial_verified: False`, as status does.
- `Series3Adapter.change_call_home(address, serial, *, enabled, dry_run, even_if_already, audit, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`:
- When `not dry_run and not S3_CALL_HOME_FRAME_VERIFIED`, raise `NotSupported("a MiniMate call-home write waits until its frame has been reproduced from a Blastware capture -- nothing sent")` before `_run`.
- Otherwise use `run_change(kind=call_home_change(enabled), retry=False)` with:
- `read_serial` = `client.connect()`, as for start/stop;
- `read_state` = `wake` + `read_call_home_raw()`, giving `enabled` / `disabled` / `unknown(0xNN)` and keeping the last raw;
- `describe_plan` = the steps `[{"sub": "0x7E", "frame": build_bw_write_frame(0x7E, image).hex()}, {"sub": "0x7F", "frame": build_bw_write_frame(0x7F, b"").hex()}]`;
- `send` = `client.write_call_home_image(image)`, returning `{"subs": ["0x81", "0x80"]}`;
- `snapshot` as in Task 2, over unescaped images.
- [ ] **Step 1: Fake support.**
- `FakeMiniMateClient(call_home_raw=<125 B>)`. The default is built from the documented 4-20-26 layout: `00 7C DC 00 00`, `[5] = 0x01`, `[6:46] = b"RADIO RING"` NUL-padded, `[117:119] = 10 03`, zeros elsewhere to 125 bytes.
- `read_call_home_raw()` steps and returns it.
- `write_call_home_image(image)` records `self.writes.append("call_home")` and stores the image for the next read.
- [ ] **Step 2: Write the failing tests:**
- `test_s3_enable_byte_reads_from_the_unescaped_block`: on the default raw → `call_home_enabled(raw) is True`. A raw with an escape spliced in before byte 5 (`00 7C 10 03 00 00 01 …`) still reads True.
- `test_s3_image_changes_only_byte_5`: `call_home_image(raw, False)` differs from `write_image(0x7E, raw)` at index 5 only, and its length is 126 (N `0x7C` + 2).
- `test_s3_image_refuses_an_unknown_byte_5`: raw with unescaped `[5] = 0x07` → `ValueError`.
- `test_s3_call_home_state`: through `Series3Adapter` with the fake → `enabled is True`, `dial_string == "RADIO RING"`, `detail["serial_verified"] is False`; the calls include `"wake"` before `"read_call_home_raw"`.
- `test_s3_live_change_is_refused_until_the_frame_is_verified`: `dry_run=False` → `NotSupported` (501), the factory never called.
- `test_s3_dry_run_shows_both_frames`: `dry_run=True` → plan steps `0x7E`/`0x7F`, `fake.writes == []`.
- `test_s3_change_once_verified` (monkeypatch `S3_CALL_HOME_FRAME_VERIFIED = True`): live `enabled=False` → `("sent", "ok", "disabled")`, `fake.writes == ["call_home"]`, `detail["snapshot"]["changed_offsets"] == [5]`.
- `test_s3_unknown_byte_5_sends_nothing` (gate open): raw with `[5] = 0x07` → `UnitStateUnknown`, no write.
- [ ] **Step 3: Run** the new file. Expected: FAIL (`ImportError: call_home_enabled`).
- [ ] **Step 4: Implement** as specified.
- [ ] **Step 5: Run** the new file plus `tests/test_device_access_change.py tests/test_server_series3_guard.py`. Expected: pass.
- [ ] **Step 6: Commit** `feat(sfm): Series-3 call-home state and audited enable/disable, live send gated until its frame is verified (phase 4)`.
### Task 4: Reproduce Blastware's Series-3 call-home write (opens the gate)
**Precondition:** Brian has found a capture of Blastware changing call-home settings, from the BW VM (CLAUDE.md names it `4-20-26/call home settings/`, BE11529), and copied the BW-TX and S3-RX files into `tests/fixtures/s3-call-home-bw/`. **If no capture exists, skip this task.** The gate stays shut, the Series-3 half of the bench (Task 7) starts by recording one, and this task runs after it.
**Files:**
- Create: `tests/fixtures/s3-call-home-bw/` (Brian's files, added with `git add -f` if they match an ignore rule) and `tests/test_s3_call_home_bw_frames.py`
- Modify: `sfm/device_access/s3.py` (`S3_CALL_HOME_FRAME_VERIFIED = True`, with a comment naming the test)
- [ ] **Step 1: Write the test** `test_sfm_builds_blastwares_call_home_write`:
1. Parse the S3-RX file with `S3FrameParser`, taking each `0xD3` data reply (`data[11:]`) in order. Parse the BW-TX file for the `0x7E` and `0x7F` request frames, using the #46 parser in `tests/test_minimate_write_frames.py` (`_frames`, `_payload`; import or copy them).
2. For each `0x7E`, work out what Blastware asked for: the unescaped byte 5 of its image.
3. Assert `build_bw_write_frame(0x7E, call_home_image(prev_read, wanted)) == bw_7e_frame` and `build_bw_write_frame(0x7F, b"") == bw_7f_frame`.
4. If Blastware also changed fields other than byte 5 in that write, assert only on writes where byte 5 is the sole difference from the read, and record the count.
- [ ] **Step 2: Run it.** Expected: PASS, with at least one write asserted. A FAIL means SFM's frame is not Blastware's: stop, record the byte differences in the spec's phase-4 notes, and leave the gate shut.
- [ ] **Step 3: Flip the gate**, then run `tests/test_s3_call_home.py`. The "refused until verified" test now fails by design: change it to assert the gate's comment names this test, and keep the monkeypatched tests.
- [ ] **Step 4: Commit** `test(s3): SFM's call-home write equals Blastware's, frame for frame -- opens the live send`.
### Task 5: DeviceAccess and the serial routes
**Files:**
- Modify: `sfm/device_access/access.py` (two methods, two constants), `sfm/server.py` (three routes, `_SERIAL_AWARE_PATHS`)
- Test: `tests/test_device_access_call_home.py`, plus additions to `tests/test_server_device_access.py`
**Interfaces:**
- Consumes: Tasks 2 and 3.
- Produces:
- `DeviceAccess.call_home_state(address, serial) -> CallHomeState` (a read, via `_dispatch`).
- `DeviceAccess.set_call_home(address, serial, *, enabled: bool, dry_run=False, even_if_already=False, caller="api") -> ChangeResult` (`change=True`). It uses `_CALL_HOME_VERIFY_TIMEOUT_S = 3.0` and `_CALL_HOME_VERIFY_INTERVAL_S = 1.0`, at most 3 read-backs one second apart, not the monitoring window.
- Routes:
- `GET /device/call_home/state?serial=&host=&tcp_port=` → the `CallHomeState` as a dict.
- `POST /device/call_home/enable` and `/device/call_home/disable`, taking `serial` (required), `host`, `tcp_port`, `dry_run`, `even_if_already` and `caller`, through `_change_response`. The statuses are the start/stop route's, including Batch 2's `sent`/`audit_id` on an unconfirmed change.
- All three go in `_SERIAL_AWARE_PATHS`. The legacy `GET`/`POST /device/call_home` stay unchanged, and outside that set.
- [ ] **Step 1: Write the failing tests:**
- `test_set_call_home_dispatches_by_series`: a `UM` serial reaches the S4 function and a `BE` serial the S3 adapter, using the fakes from Tasks 2 and 3.
- `test_set_call_home_is_never_retried`: an S4 held line that drops → raised, executed once.
- `test_call_home_routes_need_a_serial`: no `serial` → 422.
- `test_enable_route_returns_the_change_result`: a fake access → 200 and the body's `action == "enable call-home"`.
- `test_legacy_call_home_post_still_refuses_a_micromate_serial`: `_device_guard("/device/call_home", {"serial": "UM20147"})` → 501, unchanged.
- `test_call_home_routes_are_serial_aware`: the three new paths are in `_SERIAL_AWARE_PATHS`.
- [ ] **Step 2: Run.** Expected: FAIL (`AttributeError: set_call_home`).
- [ ] **Step 3: Implement**, mirroring `start_monitoring` / `device_monitor_start`.
- [ ] **Step 4: Run** the new and modified test files plus `tests/test_server_series3_guard.py`. Expected: pass.
- [ ] **Step 5: Commit** `feat(sfm): call-home state and enable/disable by serial -- GET /device/call_home/state, POST /device/call_home/{enable,disable} (phase 4)`.
### Task 6: The page — Call Home by serial
**Files:**
- Modify: `sfm/static/device_routing.js` (routes, `controlsFor`, `serialPanes`, `changeErrorText`, new `callHomeRows`), `sfm/static/sfm_webapp.js` (glue), `sfm/sfm_webapp.html` (a state box and two buttons in the Call Home tab)
- Test: `tests/test_webapp_device_routing.py`, plus a jsdom run of `page_files_load.js` in the scratchpad (not committed)
**Interfaces:**
- Consumes: Task 5's routes and Batch 2's `serialPanes` / `changeErrorText`.
- Produces:
- `DEVICE_ROUTES`:
- `call_home_state: ['GET', '/device/call_home/state', true]`
- `call_home_on: ['POST', '/device/call_home/enable', true]`
- `call_home_off: ['POST', '/device/call_home/disable', true]`
- `controlsFor(unit).callHomeChange = serialMode && (series === 3 || series === 4)`. `callHomeWrite` (the legacy multi-field form) stays `false`, with `reasons.callHomeWrite = 'By serial: use Call-home On / Off (audited). Other call-home fields wait for the THOR round.'`
- `serialPanes(...)` gains `callHomeForm: !bySerial` and `callHomeBox: bySerial`. Batch 2's existing test gets the two keys added.
- `changeErrorText(label, status, body, unit, statusText)` takes the whole label (`"Start monitoring"`, `"Enable call-home"`) and returns `` `${label} not confirmed: …` `` / `` `${label} failed: …` ``. Update its two callers and Batch 2's test.
- `callHomeRows(state) -> [[label, value], …]` returns:
- `['Call-home', 'On' | 'Off' | 'Unknown (byte 5 = 0xNN)']`
- `['Dial string', … or '—']`
- `['Series', 3 | 4]`
- [ ] **Step 1: Write the failing Node tests:**
- `test_call_home_routes_need_a_serial`: `deviceUrl('call_home_on', BLANK)` → null; with S4 → `{method: 'POST', path: '/device/call_home/enable?serial=UM20147&host=h&tcp_port=9034'}`.
- `test_call_home_change_needs_a_confirmed_series`: typed but unconfirmed → false; confirmed 3 → true; confirmed 4 → true; legacy → false.
- `test_call_home_rows`: `{enabled: true, dial_string: 'RADIO RING', series: 4}` → `[['Call-home','On'],['Dial string','RADIO RING'],['Series',4]]`; `{enabled: null, detail: {byte5: '0x07'}, series: 3}` → first row `['Call-home','Unknown (byte 5 = 0x07)']`.
- Update the `changeErrorText` and `serialPanes` tests to the new shapes.
- [ ] **Step 2: Run** `pytest tests/test_webapp_device_routing.py`. Expected: FAIL (`callHomeRows` is not defined).
- [ ] **Step 3: Implement the routing functions**, then the glue:
- By serial, the Call Home tab hides the legacy form and shows the state box via `serialPanes`, in `applyControls`.
- `readCallHome()` uses `call_home_state` and renders `callHomeRows`.
- `changeCallHome(on)` asks `confirm()` with the serial and on/off, sends `call_home_on`/`call_home_off`, reports with `changeSummary` / `changeErrorText('Enable call-home' | 'Disable call-home', …)`, then re-reads the state.
- The buttons are enabled by `controlsFor().callHomeChange`.
- HTML: `#ch-state` (a `dev-table`), `#ch-on-btn` and `#ch-off-btn` inside a `#ch-serial` box; the existing form goes in `#ch-legacy`.
- [ ] **Step 4: Run** the Node tests (pass), then the jsdom check. Extend `page_files_load.js` with:
- S4: Call Home read → rows shown, legacy form hidden;
- Off → `POST /device/call_home/disable?serial=UM20147…` sent after confirm, status from `changeSummary`;
- legacy mode: form shown;
- no script errors.
- [ ] **Step 5: Commit** `feat(sfm): the page's Call Home tab by serial -- state and audited On / Off (phase 4)`.
### Task 7: Docs, and the bench session (Brian's go per send)
**Files:**
- Modify: the spec (a "Phase 4" entry after phase 3's under Build phases), `CLAUDE.md` ("Where things stand"), and `docs/micromate_protocol_reference.md` / `docs/instantel_protocol_reference.md` (CRLF: Edit tool or byte-safe writes) for whatever the bench measures
- [ ] **Step 1: Docs before the bench.**
- Spec: what was built, with commit IDs; the gate's state; the bench questions below.
- CLAUDE.md: one status line.
- Commit `docs: phase 4 built -- call-home enable/disable by serial; bench questions`.
- [ ] **Step 2: Bench, UM20147 on its modem, idle.** One send per go:
- (a) dry run `disable`, showing frames and warnings, including "0x00 is unobserved";
- (b) `enable` with `even_if_already` (the no-op write: does a Micromate accept it?);
- (c) `disable`: read-back, the unit's screen, and the snapshot's changed offsets;
- (d) `enable`, back to how it was.
- Record each audit id and `[118:120]` before/after.
- [ ] **Step 3: Bench, BE9441 on its modem, idle.**
- If Task 4 did not run: first record Blastware changing call-home on BE9441 through the bridge, then run Task 4.
- Then (a) to (d) as above.
- [ ] **Step 4: One unit monitoring** (Brian picks which): a dry run, then one `disable` / `enable` pair. This settles whether a unit accepts a call-home write while monitoring. Unmeasured; nothing in the code assumes either answer.
- [ ] **Step 5: Record the results** in the spec and the protocol references (measured, with audit ids), and commit `docs: phase 4 bench -- call-home on/off on both series`.
@@ -1,525 +0,0 @@
# Phase 5: Changing a Unit's Settings by Serial — Implementation Plan
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** An operator edits a unit's live settings in SFM, by serial, on either series: preview old → new, send once (audited), and see what the unit now holds.
**Architecture:**
- **One pure settings codec for both series** (`micromate/setup_fields.py`), on the measured shared 2,090-byte layout.
- **Each series' adapter supplies reads, the plan and the send** to the existing `run_change` core, unchanged.
- Its "state" is a read-back verdict: `as asked` / `unchanged` / `differs`.
- Series 3 sends through `push_config_raw`; Series 4 through `plan_setup_push`.
- Series 4 also reads the unit's schedule, read-only, to refuse a change that a scheduled start would undo.
- **One audited route**, `POST /device/settings/change`. The legacy by-host write is retired.
**Tech Stack:** Python 3 (FastAPI, pytest), vanilla JS tested in Node (`tests/test_webapp_device_routing.py`).
**Spec:** `docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md` (approved by Brian 2026-11-03). Parent spec: `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md`.
## Global Constraints
- **Worktree and branch:** work in `~/seismo-relay-parity` on `feat/series4-sfm-parity`. Check `git branch --show-current` before every commit; never commit to `main`; push every commit.
- **Python:** `/home/serversdown/seismo-relay/.venv/bin/python -m pytest …` from the worktree root.
- **The suite has 16 known failures.**
- Run the full suite once before Task 1 and save the failure list in the plan workspace as `baseline-failures.txt`.
- Before every commit, run the suite, read the failure list, and confirm it equals the baseline.
- Commit in a separate call, never chained to the test run.
- **No live device traffic** in any task. The bench is after the final review, with Brian's explicit go per send.
- Never port 8200.
- Never write modem baud or modem type.
- Never send `0xA2`.
- **`CHANGELOG.md` is not touched** on this branch; it is written on `dev` at the merge.
- **No inline JavaScript.** New page logic goes in `sfm/static/device_routing.js` (DOM-free, Node-tested); glue goes in `sfm/static/sfm_webapp.js`.
- **`docs/instantel_protocol_reference.md` is CRLF.** Edit it only with the Edit tool. Keep its rows in date order.
- **Off-limits (the checker session's files):** `minimateplus/event_file_io.py`, `histogram_codec.py`, `waveform_codec.py`, `bw_xml_report.py`, `decode_check*.py`.
- **`TOOL_VERSION` is unchanged:** nothing here changes event decoding. Operational consequence: none; no migration, no backfill.
- **Grade every protocol claim** in comments and docs as measured or inferred.
- **Mutation checks:** after a mutate/restore, delete the module's `__pycache__/*.pyc` before the confirming run.
## Review Focus
1. **A Micromate with no schedule file, or a schedule read that fails.**
- A body with no records means no conflict, and the change proceeds.
- A read that raises refuses the change in plain words.
- Owner: Task 4; tests `test_no_schedule_records_is_no_conflict` and `test_an_unreadable_schedule_refuses`.
2. **A float that is stored as f32.** 0.3 reads back as 0.30000001192.
- The verdict compares bytes with the image written, never floats, so it reads `as asked`.
- Owner: Task 2; test `test_f32_values_read_back_as_asked`.
3. **A stale or foreign revision** after a keypad edit, or a preview of another unit.
- The send is refused with 409, nothing is sent, and no audit row is written.
- Owner: Tasks 4 and 5; tests `test_s4_stale_revision_sends_nothing` and `test_s3_stale_revision_sends_nothing`.
4. **Range and trigger changed in one request.** The trigger is checked against the **new** range.
- Owner: Task 2; test `test_trigger_checked_against_the_new_range`.
5. **Notes at the edges.**
- `""` clears a note.
- 41 bytes is accepted; 42 is refused; non-ASCII is refused.
- Labels are never written.
- Owner: Task 2; tests `test_note_edges` and `test_note_labels_are_never_written`.
---
## File Structure
| file | responsibility |
|---|---|
| `minimateplus/protocol.py` | **Series 3 assembly:** `assemble_compliance_content`, `is_compliance_content`, `MiniMateProtocol.read_compliance_content`. **Writes:** `push_config_raw`'s pre-check raises `ImageRefused`. |
| `minimateplus/client.py` | **Added:** `read_compliance_content()` and `read_settings_blocks()`. **Deleted:** `apply_config`, `set_project_info`, `_encode_compliance_config`. |
| `micromate/setup_block.py` | **Added:** `with_crc(content)`. |
| `micromate/setup_fields.py` (new) | **The shared, pure settings codec:** field registry, `editable_fields`, `check_changes`, `encode_setup`, `field_values`, `settings_state`, `revision`. |
| `micromate/schedule.py` (new) | **Pure:** `parse_schedule`, `ScheduleEntry`, `schedule_conflicts`. |
| `micromate/protocol.py` | **Added:** `read_file(path)`, using `0x94` then `0x48` pages. |
| `micromate/client.py` | **Added:** `read_schedule()`, `get_active_setup_raw()`, `get_prefs_content()`, `get_trigger_content()`, `get_setup_content()`. |
| `micromate/opcodes.py` | `ENABLEABLE_WRITES` gains the setup-push SUBs. |
| `sfm/device_access/errors.py` | **Added:** `SettingsChanged` and `ChangeRefused`, both 409. |
| `sfm/device_access/change.py` | **Added:** `settings_change()`. |
| `sfm/device_access/s4.py` | `s4_settings` moves onto the codec. **Added:** `s4_change_settings`. |
| `sfm/device_access/s3.py` | `Series3Adapter.settings` moves onto the codec. **Added:** `Series3Adapter.change_settings`. |
| `sfm/device_access/access.py` | **Added:** `DeviceAccess.change_settings`. |
| `sfm/server.py` | **Added:** `POST /device/settings/change`. `/device/config` and `/device/config/project` return 410. |
| `sfm/static/device_routing.js`, `sfm/static/sfm_webapp.js`, `sfm/sfm_webapp.html` | The edit form. |
| `tests/device_access_fakes.py` | The fakes gain settings blocks, a schedule, and writes. |
---
### Task 1: Series 3 — assemble a settings read into the logical block
**Measured basis (spec, 2026-11-03):** unescape each `1A` data frame and take `data[11:]`. Every frame but the last starts with one non-content `00` byte; drop it. The result is 2,090 bytes with `N = 2090` at `[0:2]`.
**Files:**
- Modify: `minimateplus/protocol.py`, near `read_compliance_config` (≈ line 913)
- Modify: `minimateplus/client.py`
- Modify: `docs/instantel_protocol_reference.md` (one dated row, 2026-11-03)
- Test: `tests/test_s3_settings_read.py` (new)
**Interfaces:**
- Produces:
- `assemble_compliance_content(frames: list[bytes]) -> bytes`. `frames` is each data reply's `frame.data`, escapes kept, in order.
- `is_compliance_content(block: bytes) -> bool`: `len == 2090` and `int.from_bytes(block[0:2], "big") == 2090`.
- `COMPLIANCE_CONTENT_LEN = 2090`.
- `MiniMateProtocol.read_compliance_content() -> bytes`:
- sends the same probe and B/C/D requests as `read_compliance_config`;
- a missing data frame raises `ProtocolError` (no `continue`);
- returns the assembled bytes **without** judging them, so a monitoring unit's device-info answer comes back for the caller to recognise.
- `MiniMateClient.read_compliance_content() -> bytes`.
- `MiniMateClient.read_settings_blocks() -> dict` with keys `event_index`, `compliance`, `trigger` and `waveform`. Each value is the bytes its existing read returns:
- `event_index`: `proto.read_event_index()`
- `compliance`: `read_compliance_content()`
- `trigger`: `proto.read_trigger_config()`
- `waveform`: `proto.read_waveform_data_raw()`
- [ ] **Step 1: Write the failing tests** in `tests/test_s3_settings_read.py`. Use `tests/fixtures/minimate-bench-10-26-26-histogram` (`unit_replies.bin` parsed with `S3FrameParser`). Group the `0xE5` frames into reads: a frame with `len(data) == 11` starts each read. Take the write images from `tests/test_minimate_write_frames.py` (`WRITES[0:13]`, `WRITES[13:26]`; the `0x71` payloads `[16:]` joined).
```python
def test_reads_assemble_to_2090_bytes(): # all 12 reads, both frame patterns (5 and 3 frames)
assert all(len(assemble_compliance_content(r)) == 2090 for r in READS)
def test_a_read_after_a_blastware_write_equals_the_write():
assert assemble_compliance_content(READS[1]) == IMAGES[0][:2090]
assert assemble_compliance_content(READS[2]) == IMAGES[1][:2090]
def test_a_monitoring_units_answer_is_not_settings(): # READS[3:8] start 0e 'BE9441'
assert [is_compliance_content(assemble_compliance_content(r)) for r in READS[3:8]] == [False] * 5
assert all(is_compliance_content(assemble_compliance_content(r)) for r in READS[:3] + READS[8:])
def test_read_compliance_content_refuses_a_missing_frame():
... # a fake transport that answers the probe and frame B, then times out: ProtocolError, nothing assembled
```
- [ ] **Step 2: Run them.** `…pytest tests/test_s3_settings_read.py -q`. Expected: FAIL (ImportError: `assemble_compliance_content`).
- [ ] **Step 3: Implement** the Produces block in `protocol.py` and `client.py`. Use `unescape_reply` from `minimateplus.framing`. The docstring cites the measurement and its fixture.
- [ ] **Step 4: Run them.** Expected: PASS (4 passed).
- [ ] **Step 5: Add a reference row** to `docs/instantel_protocol_reference.md` (Edit tool; CRLF), dated 2026-11-03, measured. Cover:
- the assembly rule;
- the round trip (2 of 2);
- `[26:28]`: Blastware writes `00 00` (11 of 11), and the unit sets `01 7f` after monitoring;
- the trailing two bytes: a per-unit Blastware constant (`7c ea` BE11529 ×9, `0c e9` BE9441 ×2), not the CRC, and never in a reply;
- `0x09 [200:202]`: echoed 9 of 9 in April; changed on 10-26 (`17 17` → `78 76`).
- [ ] **Step 6: Run the full suite** and compare the failure list with the baseline. **Then commit** (separate call): `feat(s3): assemble a settings read into the 2,090-byte block`.
---
### Task 2: The shared settings codec
**Files:**
- Create: `micromate/setup_fields.py`
- Modify: `micromate/setup_block.py`: add `with_crc(content: bytes) -> bytes`, which returns the content with `CRC-16/AUG-CCITT` over `[0:N-2]` written BE at `[N:N+2]`.
- Test: `tests/test_setup_fields.py` (new)
**Interfaces:**
- Consumes: Task 1's `assemble_compliance_content`, used in tests only. The codec itself imports nothing from `minimateplus` and nothing from `sfm`.
- Produces (all pure). Each `content` is the 2,090-byte (Series 3) or 2,092-byte (Series 4) block.
- `editable_fields(content: bytes, series: int) -> list[dict]`. Each dict has `field`, `label`, `kind` (`"number"`, `"choice"`, `"text"` or `"bool"`) and `value`, plus as relevant `unit`, `min`, `max`, `choices` (a list of `{value, label}`) and `maxlength`.
- `field_values(content: bytes, series: int) -> dict[str, Any]`: the same fields, values only.
- `check_changes(content: bytes, series: int, changes: dict) -> dict`: returns the normalised changes, or raises `SettingsValueError(ValueError)` with a plain sentence. It has two kinds of check: static (names, types, choices, limits) and content-dependent (unit strings, the trigger against the range).
- `encode_setup(content: bytes, series: int, changes: dict) -> bytes`:
- same length as `content`;
- only the changed fields' bytes move;
- bit fields are patched bit by bit;
- Series 3 also sets `[26:28] = 00 00` (`S3_BLASTWARE_FIXED`);
- Series 4 returns `with_crc(...)`.
- `settings_state(before: bytes, written: bytes, now: bytes, *, series: int) -> str`. It compares `[0:2090]`:
- `"as asked"` if `now` equals `written` (Series 4 also needs `crc_ok(now)`);
- else `"unchanged"` if `now` equals `before`;
- else `"differs"`.
- `revision(blocks: list[bytes]) -> str` = `hashlib.sha256(b"".join(blocks)).hexdigest()[:16]`.
- `S3_ALARM_WRITE_MEASURED = False`. While False, `geo_alarm_ips` is shown (read-only, `kind` plus `"readonly": True`) and refused in `check_changes`.
**The field registry** (content offsets; channel `k` = `1708 + 48·k`, `k` = 0, 1, 2 for the geophones):
| field | series | bytes | values (exact) |
|---|---|---|---|
| `record_mode` | 3 | `[5]` | `single_shot`=0, `continuous`=1, `histogram`=3, `histogram_continuous`=4 |
| `record_mode` | 4 | `[5]` | `waveform`=1, `manual`=2, `histogram`=3, `combo`=4 |
| `sample_rate` | 3, 4 | `[6:8]` u16 BE | {1024, 2048, 4096} |
| `histogram_interval_s` | 3, 4 | `[8:10]` u16 BE | {2, 5, 15, 60, 300, 900} |
| `record_time_s` | 3 | `[18:22]` f32 BE | 1.0 ≤ v ≤ `S3_MAX_RECORD_S[sample_rate]` = {1024: 104, 2048: 52, 4096: 26}, and ≤ 13 when `record_mode` is `histogram_continuous` (the **new** mode and rate if they change too) |
| `record_time_s` | 4 | `[18:22]` f32 BE | 1.0 ≤ v ≤ 90.0 |
| `geo_trigger_ips` | 3, 4 | ch k `+30` f32 BE, all three | 0.005 ≤ v ≤ 10.0, a multiple of 0.001 (within 1e-9), and ≤ the (new) range's full scale (10.0 / 1.25) |
| `geo_range` | 3 | ch k `+29` u8, all three | `normal`=0, `sensitive`=1 |
| `geo_alarm_ips` | 3 (gated) | ch k `+38` f32 BE, all three | 0.005 ≤ v ≤ full scale |
| `job_number` | 3, 4 | `[40:42]` u16 BE | 1 ≤ v ≤ 9999 |
| `job_number_shown` | 3, 4 | `[39]` bit `0x02` | bool |
| `note_1` … `note_4` | 3, 4 | value `[144+64n : 186+64n]`; label `[122+64n : 144+64n]` read only | printable ASCII 0x20–0x7E, ≤ 41 bytes, zero-filled to 42 |
The limits are **the units' own, from Instantel's manuals** (Brian, 2026-11-03), cited in the module as comments:
- **Trigger** 0.005–10 in/s, steps of 0.001: MiniMate Plus manual 716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual 721U0201 Rev 06, *Geophone Trigger Level*.
- **Record time:**
- Micromate 1–90 s (*Record Time*).
- MiniMate: §4.4's *Maximum Record Times*, 1 MB unit, channels 1–4; §3.8.9, 13 s in Histogram Combo.
- **Job number** 1–9999: both manuals.
**A level write is refused** unless all three geophone channels' unit string, `ch +34:+38` with NULs and `.` stripped, equals `in`. Measured: `in.` and `in` both occur on UM20147. A unit set to Metric is unmeasured.
- [ ] **Step 1: Write the failing tests** in `tests/test_setup_fields.py`:
```python
def test_s3_reproduces_every_blastware_write():
# BE11529's 9 April images (bridges/captures/4-20-26/**/raw_bw_*.bin), in time order (the HHMMSS in
# the name): before = the previous image; the first (151921) uses the assembled 1A read in its own
# raw_s3 capture if that read is whole, else it is skipped (say so in the test). BE9441's 2 images:
# before = the assembled READS[0], then image 1. changes = field_values(after) for every field whose
# value differs. Assert encode_setup(before, 3, changes)[:2090] == after[:2090].
# The 16:26 write also moves [25] (mic on): include `_sensors_mic` as a test-only patch helper,
# not a registry field.
def test_s4_fixture_pairs_reproduce():
# for every ordered pair (a, b) of tests/fixtures/micromate-setup/*.bin whose differing bytes outside
# [2090:2092] all lie inside registry fields: encode_setup(a, 4, {f: field_values(b)[f] for differing f}) == b
def test_trigger_checked_against_the_new_range(): ... # Series 3: {"geo_range": "sensitive", "geo_trigger_ips": 2.0} refuses (above 1.25); 1.25 passes; {"geo_trigger_ips": 2.0} alone on Normal passes
def test_limits_refuse_outside_values(): ... # 0.004 and 10.001 in/s; 0.3005 (not a 0.001 step); job 0 and 10000; S4 0.9 and 90.1 s;
# S3 at 4096 sps: 26 ok, 26.1 refused; S3 histogram_continuous: 13 ok, 13.1 refused;
# S3 {"sample_rate": 1024, "record_time_s": 100} passes from a 4096 sps block (the new rate counts);
# sample rate 8192; interval 30
def test_field_not_offered_for_the_series(): ... # geo_range on series 4 -> SettingsValueError naming the series
def test_alarm_is_read_only_until_measured(): ... # Series 3 geo_alarm_ips -> SettingsValueError while S3_ALARM_WRITE_MEASURED is False
def test_metric_unit_string_refuses_level_writes(): ... # ch +34 = b"mm\x00\x00" -> SettingsValueError; b"in.\x00" and b"in\x00\x00" pass
def test_note_edges(): ... # "" clears; 41 bytes ok; 42 refused; "café" refused
def test_note_labels_are_never_written(): ... # changing note_2 moves only [208:250]
def test_bit_fields_keep_unknown_bits(): ... # [39] = 0x81: job_number_shown True -> 0x83, False -> 0x81
def test_s3_fixed_bytes(): ... # any S3 encode sets [26:28] = 00 00
def test_s4_encode_recomputes_the_crc(): ... # crc_ok(encode_setup(fixture, 4, {"job_number": 7}))
def test_f32_values_read_back_as_asked(): ... # written = encode(0.3); settings_state(before, written, written) == "as asked"
def test_settings_state(): ... # "as asked" / "unchanged" / "differs"; S4 with a bad CRC -> "differs"
def test_revision_is_stable_and_content_sensitive(): ...
```
- [ ] **Step 2: Run them.** Expected: FAIL (ModuleNotFoundError: `micromate.setup_fields`).
- [ ] **Step 3: Implement** `micromate/setup_fields.py` and `with_crc`. Decode via the registry (not via `decode_setup`, whose notes are keyed by label). Note labels come from the unit and are display only.
- [ ] **Step 4: Run them.** Expected: PASS. Then mutation-check `S3_BLASTWARE_FIXED` (remove it: the Blastware-write test fails), delete the `.pyc`, and restore.
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(codec): one settings codec for both series, on the shared layout`.
---
### Task 3: Micromate — read the schedule file
**Measured basis:** reference *The scheduler, and a generic file transfer* and *The schedule record format*.
- `0x94 <path>` opens a file for read; `offset` = the path's length, and the payload is the path, unpadded.
- `0x48` reads the next page, repeated until an all-zero 11-byte response.
- The file is 260-byte records. `[4]` is the half-hour slot. `[6]` is the action bitmask: 2 start-with-setup, 4 stop, 8 self-check, 16 ACH. `[7]` is the name length; `[8:260]` is the name.
**Files:**
- Create: `micromate/schedule.py`
- Modify: `micromate/protocol.py` (`read_file`), `micromate/client.py`
- Modify: `docs/micromate_protocol_reference.md`: one line under the scheduler section saying SFM reads it (read-only) from 2026-11-03.
- Test: `tests/test_micromate_schedule.py` (new)
**Interfaces:**
- Produces:
- `SCHEDULE_PATH = "\\system\\schedule\\schedule.dat"`.
- `MicromateProtocol.read_file(path: str) -> bytes`: the concatenated content of each `0x48` page after the page-0 descriptor, stopping at the all-zero response; at most 64 pages, else `ProtocolError`.
- `MicromateClient.read_schedule() -> bytes`.
- `MicromateClient.get_active_setup_raw() -> str`: the `0x41` name up to its NUL, **not** stripped.
- `MicromateClient.get_prefs_content() -> bytes` (`0x08`), `get_trigger_content() -> bytes` (`0x2E`) and `get_setup_content() -> bytes` (`0x1A`), each `_content(...)` of its read.
- `@dataclass(frozen=True) class ScheduleEntry`: `index: int`, `time: str` (`"HH:MM"`), `day: int`, `action_bits: int`, `actions: tuple[str, ...]`, `setup: str`.
- `parse_schedule(body: bytes) -> list[ScheduleEntry]`: 260-byte records; a record with `[4:8]` all zero and no name ends the list. `actions` names the bits 2/4/8/16 as `start_with_setup`, `stop`, `self_check` and `call_home`; any other bit becomes `unknown(0xNN)`.
- `schedule_conflicts(entries, active_setup: str) -> list[ScheduleEntry]`: start entries whose setup, compared case-insensitively after `strip()`, is not the active setup.
- [ ] **Step 1: Write the failing tests.** Parse the bodies from `bridges/captures/9-24-26 - micromate2/raw_s3_20260924_191835_read_scheduler.bin` (frames 0–4), and from the two `raw_*_20260925_*` captures, with `MicromateFrameParser`.
```python
def test_the_read_capture_parses(): # 2 records: start-with-setup 07:30 (40-char name), call_home 19:30 (no name)
def test_the_five_entry_schedule_parses(): # 07:30 start TEST1.mmb, 08:00 stop, 08:30 self_check, 09:00 start test2.mmb, 19:30 call_home
def test_conflicts_are_case_insensitive(): # active "test1.MMB" -> only the test2.mmb start conflicts
def test_no_schedule_records_is_no_conflict(): assert schedule_conflicts(parse_schedule(bytes(524)), "x.mmb") == []
def test_read_file_sends_the_path_unpadded_and_stops_at_zeros(): ... # a fake protocol: 0x94 offset 0x001D, then 0x48 until all-zero
def test_get_active_setup_raw_keeps_spaces(): ... # " LOC 4 .mmb " survives
```
- [ ] **Step 2: Run them.** Expected: FAIL (ModuleNotFoundError: `micromate.schedule`).
- [ ] **Step 3: Implement** the Produces block. `read_file` builds `0x94` with `build_request(0x94, len(path), bytes(10), path.encode("ascii"))`. Both SUBs are already in `READ_SUBS`.
- [ ] **Step 4: Run them.** Expected: PASS.
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(micromate): read the schedule file (read-only)`.
---
### Task 4: Change-path pieces and the Series 4 settings change
**Files:**
- Modify: `sfm/device_access/errors.py`, `sfm/device_access/change.py`, `micromate/opcodes.py`, `sfm/device_access/s4.py`, `tests/device_access_fakes.py`
- Modify: `tests/test_micromate_execute.py`, `tests/test_micromate_opcodes.py`. Their over-ceiling example `0x71` becomes enableable here; use `0xA8` (delete one event) instead.
- Test: `tests/test_device_access_s4_settings.py` (new)
**Interfaces:**
- Consumes:
- Task 2: `editable_fields`, `field_values`, `check_changes`, `encode_setup`, `settings_state`, `revision`.
- Task 3: `read_schedule`, `parse_schedule`, `schedule_conflicts`, `get_active_setup_raw`, and the content getters.
- `micromate.writes.plan_setup_push(prefs, trigger, setup, name)`.
- Produces:
- `class SettingsChanged(DeviceError)`, `http_status = 409`.
- `class ChangeRefused(DeviceError)`, `http_status = 409`.
- `settings_change() -> ChangeKind("change settings", "as asked", "applied")`.
- `ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F, 0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72})`.
- `s4_settings(client, serial) -> UnitSettings`. It keeps every current field, plus `detail["editable"] = editable_fields(setup, 4)`. The revision comes only from a preview (dry run), never from this read.
- `s4_change_settings(client, serial, *, changes: dict, revision: Optional[str], dry_run: bool, audit, address, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`.
**`s4_change_settings` behaviour**, through `run_change` (`even_if_already=False`):
- **`read_state`, first call:**
- Read the run state.
- `calling_home` and `unknown*` are returned as they are.
- `monitoring` raises `UnitStateUnknown(f"{serial} is monitoring -- stop it first (a stop makes it call in if call-home is on) -- nothing sent")`.
- Read the name (raw), prefs, trigger and setup.
- `check_changes` (a `SettingsValueError` becomes `BadRequest`).
- When live, `revision([name.encode("ascii"), prefs, trigger, setup])` must equal the request's. Otherwise raise `SettingsChanged("the unit's settings changed since the preview -- preview again; nothing sent")`.
- `image = encode_setup(setup, 4, changes)`.
- Read the schedule; a read error is kept as a blocking reason.
- Return `settings_state(setup, image, setup, series=4)`.
- **Later calls:** read the setup and return `settings_state(before, image, now, series=4)`.
- **`describe_plan`:**
- `plan_setup_push(prefs, trigger, image, name).describe()`, plus `fields` = `{f: {label, old, new}}` for the changed fields, `revision`, `warnings` and `blocked`.
- `warnings` always includes: "this reads the unit's keypad edit buffer: if someone is in its menu, their unsaved edits are sent too".
- `blocked`:
- the name is `factory.MMB` (case-insensitive): "this unit is running its factory setup; load any other setup on its keypad, then try again";
- each schedule conflict: "this unit's schedule loads <setup> at <HH:MM>, which would replace this change";
- a schedule read error: "could not read this unit's schedule (<error>) -- SFM will not change a unit whose schedule it cannot check";
- `plan_setup_push` raising `ValueError` (a block size or header THOR's offsets were never seen at, or a failed checksum): "this unit's <message> -- SFM has not seen a block like it".
- When `blocked` is non-empty, `steps` is `[]`, and a live call raises `ChangeRefused("; ".join(blocked) + " -- nothing sent")`.
- When the schedule names the active setup, `warnings` adds: "the unit's schedule loads this setup at <HH:MM>; the change survives it".
- **`send`:** `client.protocol.execute(plan)`, as `s4_change_call_home` does.
- **`snapshot`:**
- `fields`: `{f: {label, old, new, now}}`;
- `before` / `after` hex of the setup;
- `changed_offsets`;
- `prefs` and `trigger`: before hex only.
- **`is_refusal`**, **`is_ring`** and **`pre_send`**: as in `s4_change_call_home`.
**Validation order:** a live call without `revision` is refused before any I/O, in Task 6's `DeviceAccess` (not here).
- [ ] **Step 1: Write the failing tests.** Extend `FakeMicromateClient` with:
- `setup` (default: `tests/fixtures/micromate-setup/um20147_baseline.bin`'s last 2,092 bytes);
- `prefs`, `trigger` and `active_name` (default `"test2.mmb"`);
- `schedule_body` (default `bytes(524)`) and `schedule_error`;
- `execute` applies a setup-push plan's `0x71` data to `self.setup` (re-adding the CRC with `with_crc`), so a read-back sees it.
```python
def test_s4_dry_run_previews_old_to_new_and_sends_nothing(): # fields == {"geo_trigger_ips": {"label": ..., "old": 0.5, "new": 0.3}}; revision present; fake.executed == []
def test_s4_trigger_change_sends_the_push_and_verifies(): # subs [0xDA,0x68,0x73,0x82,0x83,0x71,0x72]; outcome sent/ok; state_after "as asked"
def test_s4_stale_revision_sends_nothing(): # SettingsChanged; fake.executed == []; audit has no rows
def test_s4_already_as_asked_is_skipped(): # outcome skipped, nothing executed
def test_s4_monitoring_is_refused(dry_run in (True, False)): # "stop it first" and "nothing sent"
def test_s4_factory_setup_is_refused_live_and_shown_in_preview():
def test_s4_schedule_conflict_blocks(): # schedule starts "other.mmb" at 07:00 -> ChangeRefused naming other.mmb and 07:00
def test_s4_schedule_on_the_active_setup_warns_only():
def test_an_unreadable_schedule_refuses():
def test_no_schedule_records_is_no_conflict(): # bytes(524) -> sent
def test_s4_a_lost_ack_records_what_the_unit_holds(): # execute_error -> outcome failed, sent True, snapshot present
def test_s4_unseen_block_size_is_blocked(): # prefs 91 B -> preview blocked; live ChangeRefused; nothing executed
def test_setup_push_subs_are_now_enableable():
```
- [ ] **Step 2: Run them.** Expected: FAIL (ImportError: `s4_change_settings`).
- [ ] **Step 3: Implement** the Produces block and update `s4_settings`. In the two opcode tests, swap the over-ceiling example to `0xA8`.
- [ ] **Step 4: Run them**, plus `tests/test_micromate_execute.py`, `tests/test_micromate_opcodes.py`, `tests/test_micromate_writes.py` (THOR's setup-push frames still reproduce) and `tests/test_device_access_s4_call_home.py`. Expected: PASS.
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(s4): change a Micromate's settings by serial, audited, schedule-checked`.
---
### Task 5: The Series 3 settings change
**Files:**
- Modify: `sfm/device_access/s3.py`, `minimateplus/client.py` (`push_config_raw` pre-check), `tests/device_access_fakes.py`
- Test: `tests/test_device_access_s3_settings.py` (new)
**Interfaces:**
- Consumes:
- Task 1: `read_compliance_content`, `read_settings_blocks`, `is_compliance_content`.
- Task 2: the codec.
- Task 4: `settings_change`, `SettingsChanged`, `ChangeRefused`.
- `MiniMateClient.push_config_raw(event_index, compliance, trigger, waveform)`.
- Produces:
- `push_config_raw` raises `ImageRefused` (from `minimateplus.protocol`) when its pre-check refuses a block, before any frame.
- `Series3Adapter.settings(address, serial) -> UnitSettings`. It is built on `read_compliance_content` and the codec, with the same top-level fields as today, plus `detail["editable"]`. A non-settings answer raises `UnitStateUnknown(S3_SETTINGS_WHILE_MONITORING)`.
- `S3_SETTINGS_WHILE_MONITORING = "did not return its settings -- a MiniMate answers this way while monitoring; stop monitoring first"`.
- `Series3Adapter.change_settings(address, serial, *, changes, revision, dry_run, audit, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`, through `run_change` and `self._run(address, op, retry=False)`:
- `read_serial`: `client.connect().serial`.
- **`read_state`, first call:**
- Wake, then `read_settings_blocks()`.
- A non-settings `compliance` raises `UnitStateUnknown(f"{serial} {S3_SETTINGS_WHILE_MONITORING} -- nothing sent")`.
- `check_changes`, and the live revision check over `[event_index, compliance, trigger, waveform]`.
- Compute `image = encode_setup(...)` and return `settings_state(...)`.
- **Later calls:** wake, `read_compliance_content()`, then the verdict.
- **`describe_plan`:**
- `steps` in Blastware's order: 68 (event index, as read), 73, 71 (settings block, 2,092 B), 72, 82 (trigger, as read), 83, 69 (waveform data, as read), 74, 72. Each step has `sub`, `what` and `data_len`.
- `fields`, `revision` and `warnings` as Series 4. The warning: "the two bytes after the settings block go out as 00 00 (Blastware sends its own constant; effect unmeasured)".
- **`send`:** `client.push_config_raw(event_index, image, trigger, waveform)`.
- **`is_refusal`:** `isinstance(e, ImageRefused)`.
- **`snapshot`:** as Series 4, without prefs and trigger.
- [ ] **Step 1: Write the failing tests.** Extend `FakeMiniMateClient` with:
- `settings_blocks`: the default compliance is BE9441's assembled 10-26 read 2; `event_index`, `trigger` and `waveform` are the `0x68`, `0x82` and `0x69` payloads (`[16:]`) of `WRITES[13:26]` in `tests/test_minimate_write_frames.py`, each minus its two trailing bytes (a write is the read plus two);
- `push_config_raw` records its four arguments and makes the compliance the new `read_compliance_content`;
- `monitoring_settings=True` returns a device-info-shaped block.
```python
def test_s3_settings_read_uses_the_codec(): # editable includes geo_range; record_mode "histogram"; notes by slot with unit labels
def test_s3_dry_run_previews_and_sends_nothing():
def test_s3_trigger_change_sends_the_units_own_blocks(): # push args: event_index/trigger/waveform == the read blocks; compliance == encode_setup(...)
def test_s3_change_verifies_by_read_back(): # outcome sent/ok, state_after "as asked", snapshot fields old/new/now
def test_s3_stale_revision_sends_nothing():
def test_s3_monitoring_is_refused(dry_run in (True, False)):
def test_s3_a_refused_image_is_audited_as_nothing_sent(): # push_config_raw raises ImageRefused -> row sent 0, "refused before sending"
def test_push_config_raw_precheck_raises_image_refused(): # a 2,089-byte compliance block -> ImageRefused, no frame written
```
- [ ] **Step 2: Run them.** Expected: FAIL (AttributeError: `change_settings`).
- [ ] **Step 3: Implement** the Produces block.
- [ ] **Step 4: Run them**, plus `tests/test_s3_call_home.py`, `tests/test_minimate_write_frames.py` and `tests/test_device_access_*`. Expected: PASS, except the tests Task 6 deletes or rewrites. If one fails here only because it pins `apply_config`, leave it for Task 6 and note that in the ledger.
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(s3): change a MiniMate's settings by serial on the shared codec`.
---
### Task 6: Device access, the route, and retiring the legacy write
**Files:**
- Modify: `sfm/device_access/access.py`, `sfm/server.py`, `minimateplus/client.py`
- Delete: `poc_set_project.py`. Remove `exp_compliance_only` (and its registration) from `experiments.py`.
- **Ruling (spec: "the legacy write is retired"):** both write a live unit through the retired encoder, which #46 found wrong. Git keeps them.
- Modify tests:
- `tests/test_s3_compliance_anchor_fields.py`: remove its write-side tests (the encoder is gone).
- `tests/test_minimate_write_frames.py`: `test_apply_config_writes_the_units_own_trigger_block` moves to Task 5's `test_s3_trigger_change_sends_the_units_own_blocks`; delete it here.
- `tests/test_server_series3_guard.py`: drop `apply_config` from `WRITES` and its fake method.
- `tests/test_server_device_access.py`: `/device/config` now 410.
- Test: `tests/test_device_access_settings.py` (new), `tests/test_server_settings_change.py` (new)
**Interfaces:**
- Consumes: Task 4's `s4_change_settings` and Task 5's `Series3Adapter.change_settings`.
- Produces:
- `DeviceAccess.change_settings(address, serial, *, changes: dict, revision: Optional[str], dry_run: bool = False, caller: str = "api") -> ChangeResult`:
- `normalise_serial`, then `series_for_serial`;
- `changes` must be a non-empty dict, else `BadRequest`;
- a live call without `revision` raises `BadRequest("preview first: a live change needs the revision from its preview -- nothing sent")`;
- a live call with no audit log raises `NotSupported` (as `set_call_home`);
- `_dispatch(..., change=True)` with `verify_timeout_s=_SETTINGS_VERIFY_TIMEOUT_S = 2.0` and `verify_interval_s=_SETTINGS_VERIFY_INTERVAL_S = 1.0`.
- `POST /device/settings/change`:
- query: `serial` (required), `host`, `tcp_port`, `port`, `baud`, `dry_run`, `caller`;
- JSON body `{"changes": {...}, "revision": "..."}`;
- returns `_change_response(...)`;
- added to `_SERIAL_AWARE_PATHS`.
- `POST /device/config` and `POST /device/config/project` return **410** with `{"detail": "retired: change a unit's settings by serial with POST /device/settings/change (audited, previewed, read back)"}`. Remove the cache-dirty hooks that only these routes called; keep the read routes.
- Delete `MiniMateClient.apply_config`, `set_project_info` and `_encode_compliance_config`, and any import left orphaned.
- [ ] **Step 1: Write the failing tests:**
```python
def test_live_change_without_revision_is_refused_before_io(): # factory never called
def test_empty_changes_is_a_bad_request():
def test_change_settings_dispatches_by_series_with_change_true():
def test_route_dry_run_returns_fields_and_revision(): # 200, body.plan.fields, body.plan.revision
def test_route_verified_change_is_200_and_mismatch_409():
def test_route_unconfirmed_carries_sent_and_audit_id():
def test_route_refusal_is_409_with_reason(): # ChangeRefused / SettingsChanged / monitoring
def test_legacy_config_routes_are_gone(): # both 410, nothing reaches a client factory
def test_settings_change_is_serial_aware(): # in _SERIAL_AWARE_PATHS; a UM serial goes to the Series-4 path
```
- [ ] **Step 2: Run them.** Expected: FAIL (404 / AttributeError).
- [ ] **Step 3: Implement** the Produces block, the deletions, and the test updates listed under Files.
- [ ] **Step 4: Run them**, plus `tests/test_server_*.py`. Expected: PASS. Check that `grep -rn "apply_config\|set_project_info\|_encode_compliance_config" --include=*.py .` finds only comments and history.
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(sfm): POST /device/settings/change; retire the legacy config write`.
---
### Task 7: The page — edit, preview, send, "the unit now holds"
**Files:**
- Modify: `sfm/static/device_routing.js`, `sfm/static/sfm_webapp.js`, `sfm/sfm_webapp.html`
- Modify: `CLAUDE.md` (the "Where things stand" Series-4 parity line: phase 5 built, bench pending), and the spec's status line ("Built 2026-11-xx; bench pending").
- Test: `tests/test_webapp_device_routing.py` (extend `EXPORTS` and cases), `tests/test_webapp_static.py`
**Interfaces:**
- Consumes: `UnitSettings.detail.editable` / `.revision`, and the `ChangeResult` shapes from Tasks 4–6.
- Produces (DOM-free, in `device_routing.js`):
- `DEVICE_ROUTES.settings_change = ['POST', '/device/settings/change', true]`; remove `config_write`.
- `controlsFor(unit)`: `configWrite: serialMode && (series === 3 || series === 4)`; `reasons.configWrite: 'By serial only: Preview, then Send (audited).'`
- `settingsFormFields(st) -> Array<{field, label, kind, value, unit?, min?, max?, choices?, maxlength?, readonly?}>`: from `st.detail.editable`, in that order.
- `settingsChanges(fields, edited) -> object`: only fields whose edited value differs. Numbers compare as numbers; read-only fields are ignored.
- `settingsPreviewRows(body) -> Array<[label, old, new]>`, from `body.plan.fields`.
- `settingsBlockedText(body) -> string`: `body.plan.blocked` joined; `''` if none.
- `settingsResultRows(body) -> Array<[label, old, new, now]>`, from `body.detail.snapshot.fields`.
- **Page behaviour** (`sfm_webapp.js` glue; HTML ids `cfg-edit`, `cfg-preview-btn`, `cfg-send-btn`, `cfg-preview`, `cfg-result`):
- The serial-mode Config pane heading reads **"On the unit <SERIAL> — read <HH:MM>"**.
- The form is built from `settingsFormFields`.
- **Preview** POSTs a dry run and shows old → new, warnings and blocked reasons. It keeps `revision` and enables **Send** only when nothing is blocked and something changes.
- **Send** asks `confirm()` naming the serial and the fields, then POSTs live with the kept revision and shows "the unit now holds" rows. Errors go through `changeErrorText`.
- Editing any field after a preview disables **Send** until the next preview.
- The by-host legacy form loses its write button. Its read stays.
- No inline script; listeners via `addEventListener`.
- [ ] **Step 1: Write the failing Node-run cases** in `tests/test_webapp_device_routing.py`:
- `controlsFor` gives `configWrite` true by serial for both series, and false by host;
- `settingsChanges` returns only differing fields and compares `0.30` with `0.3` as equal;
- `settingsPreviewRows` / `settingsResultRows` / `settingsBlockedText` on bodies shaped as Task 6 returns them;
- `deviceUrl('settings_change', unit)` → `/device/settings/change?serial=…`;
- `config_write` is no longer a route.
In `tests/test_webapp_static.py`, assert the page has no inline `<script>` body and loads both static files.
- [ ] **Step 2: Run them.** `…pytest tests/test_webapp_device_routing.py tests/test_webapp_static.py -q`. Expected: FAIL (`settingsChanges` is not a function).
- [ ] **Step 3: Implement** the Produces block and the page behaviour.
- [ ] **Step 4: Run them.** Expected: PASS. Then run the page under the jsdom harness pattern from phase 4 (`smoke/page_files_load.js` in the scratchpad): the page loads with no console error, and a stubbed dry-run body renders the preview rows.
- [ ] **Step 5: Update `CLAUDE.md`** and the spec status line. **Run the full suite** and compare with the baseline. **Commit:** `feat(webapp): edit a unit's settings by serial: preview, send, read back`.
---
## After the build: final review, then the bench
The bench is not a task: it runs after the whole-branch review and its fixes, with Brian at the units, and **each send needs his explicit go**. Run SFM with `ringkit/sfm_parity.py` (port 8299; never 8200). Order:
1. **Read-only, both units:**
- `GET /device/settings` by serial; Brian matches it against each unit's screen.
- UM20147: `read_schedule` (measure what a unit with no schedule answers, and whether `0x08` shows the scheduler switch).
2. **Dry runs** of a trigger change on each unit. Read the preview with Brian.
3. **One field per unit**, with Brian's go:
- the trigger (UM20147 0.5 → 0.3; BE9441 0.04 → 0.05);
- read back; Brian checks the unit's menu;
- change it back, with another go.
4. **A notes change** on each (go).
5. **A several-field "backup unit" change** on each (go).
6. **Refusals:**
- a dry run while monitoring (expect the refusal);
- UM20147 with a schedule naming another setup, if Brian sets one up in THOR (expect the block).
7. **Alarm level (Series 3):**
- one write with Brian's go, read back and checked on BE9441's menu;
- only then flip `S3_ALARM_WRITE_MEASURED`, in its own commit naming the bench result.
Record everything in the spec's bench section and both protocol references (measured), then the devlog.
@@ -1,655 +0,0 @@
# Monitor logs (.MLG) and each unit's monitoring timeline — Implementation Plan
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** SFM reads Blastware `.MLG` files, stores them, and answers "was unit X monitoring at
time T?" and "when was it not, and why?" from each unit's monitoring timeline.
**Architecture:**
- **Codec library:** a pure reader and writer in `minimateplus/mlg_file.py`.
- **SFM:**
- two new tables, plus the original files kept in the waveform store
- one ingest function shared by the HTTP route and the bulk-import script
- the timeline as a pure function over stored rows, computed on each request
**Tech Stack:** Python 3.10, FastAPI, SQLite (`sfm/database.py`), pytest.
**Spec:** `docs/superpowers/specs/2026-11-09-mlg-unit-timeline-design.md`. Read it first: the
measured format, session shapes and anti-goals are there and are not repeated here.
## Global Constraints
- **Where to work:** worktree `~/seismo-relay-mlg`, branch `feat/mlg-import`.
- Never commit to `dev` or `main`.
- Do not touch `CHANGELOG.md` (it is written on `dev` at merge).
- **Do not edit** `minimateplus/event_file_io.py`, `decode_check.py`, `histogram_codec.py` or
`waveform_codec.py`. Another session owns them; import from them only.
- **Running tests:** `cd ~/seismo-relay-mlg && ~/seismo-relay/.venv/bin/python -m pytest …`.
- The worktree has no venv. The tests put the worktree first on `sys.path`.
- `httpx` is not installed, so `starlette.testclient` tests skip silently. Test routes by
calling the route functions directly.
- **Baseline:** 1,659 passed, 63 skipped, 0 failed. Every commit keeps 0 failed. Read the
summary line, not just the exit code.
- That baseline needs the main checkout's git-ignored fixtures in the worktree. They were
copied on 2026-11-13; without them, 13 `idf`/`save_shape` tests fail.
- If they are missing: `rsync -a --ignore-existing ~/seismo-relay/tests/fixtures/ tests/fixtures/`
- **The codec library stays pure:** `minimateplus/` never imports `sfm`, never touches a DB,
and does no I/O beyond reading a path it was given.
- **The checksum:** CRC-16/AUG-CCITT (poly `0x1021`, init `0x1D0F`, no reflection), over
`record[0:288]`, stored little-endian at `record[290:292]`. Bytes `[288:290]` are `00 00`.
- **The format:**
- prefix `10 00 01 80 00 00 "Instantel\0" 07 2c` (18 bytes), then whole 292-byte records
- each record starts with its length `22 01` (290 LE)
- id `0e a0` is the header record (always first), `0e 80` a log record
- year little-endian in every timestamp
- **Time:** unit times are naive `datetime`s on the unit's own clock, stored with
`.isoformat()` and never converted. File times are aware UTC `datetime`s.
- **Fixtures:** `tests/fixtures/` is git-ignored, so new fixtures need `git add -f`.
- **Docs:** `docs/instantel_protocol_reference.md` is LF (enforced by `tests/test_line_endings.py`).
- **Commit messages** end with:
```
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
```
## Review Focus
1. **An empty file whose name prefix matches two known serials** (`BE11010304.MLG` with both
`BE1101` and `BE11010` known) resolves to the longest, `BE11010`. Test: Task 4,
`test_empty_file_takes_the_longest_known_serial`.
2. **One request with a good file and a corrupted one** stores the good file and refuses the bad
one per file. Nothing of the bad one lands: no row, no file in the store. Test: Task 6,
`test_import_route_stores_good_file_and_refuses_bad_one`.
3. **The same open "monitoring started" record arriving in a second file** (a re-forward, or a
cable download) is stored once, despite its NULL stop. Test: Task 3,
`test_open_record_is_stored_once`.
4. **A serial with no `.MLG` data** gets an empty timeline and `unknown`, never a 500 or a
"not monitoring". Test: Task 6, `test_timeline_routes_for_unknown_serial`.
5. **`at` exactly on a session's start or stop, or inside the repeated hour after the
clock step back,** gives a defined answer: boundaries count as monitoring, and the repeated
hour is `ambiguous`. Tests: Task 5, `test_monitoring_at_boundaries_are_inclusive`,
`test_clock_step_back_is_not_a_negative_gap`.
---
### Task 1: The reader, and one shared CRC
**Files:**
- Create: `minimateplus/crc.py`, `minimateplus/mlg_file.py`, `tests/test_mlg_file.py`
- Modify: `minimateplus/models.py` (add `MlgRecord`, `MlgFile` after `MonitorLogEntry`)
- Modify: `micromate/setup_block.py:63-69` (`_crc16_aug_ccitt` calls the shared function)
- Fixtures: `tests/fixtures/mlg-11-9-26/` (force-added)
**Interfaces:**
- Produces:
- `minimateplus.crc.crc16_aug_ccitt(data: bytes) -> int`
- `models.MlgRecord`, with fields:
- `index: int`: position in the file; 0 is the header record
- `start: datetime`, `stop: Optional[datetime]`
- `flags: int`, `trigger_source: int`, `serial: str`
- `text_raw: bytes`: exactly `record[34:288]`
- `event_time: Optional[datetime]`
- `text: str`, `trigger_level: Optional[str]`, `description: str`
- `crc_ok: bool`
- property `is_start` (`flags == 0xFFFF`)
- `models.MlgFile`:
- fields `serial: Optional[str]`, `records: list[MlgRecord]` (log records only, file order)
- properties `empty` (no records and no serial) and `crc_failures -> list[int]` (the indexes)
- `mlg_file.MlgFormatError(ValueError)`, `mlg_file.MLG_PREFIX: bytes`,
`mlg_file.RECORD_SIZE = 292`
- `mlg_file.parse_mlg(data: bytes) -> MlgFile`, `mlg_file.read_mlg(path) -> MlgFile`
- [ ] **Step 1: Copy the fixtures and force-add them**
Copy into `tests/fixtures/mlg-11-9-26/` with `cp -p`:
- from `~/dl2-archive/mlg/mlg-slice/`: `BE128443065.MLG`, `BE128443067.MLG`,
`BE128443068.MLG`, `BE128443155.MLG`, `BE128443156.MLG`, `BE6907750.MLG`, `BE6907751.MLG`
- from `~/dl2-archive/mlg/mlg-slice2/`: `BE8081.MLG`, `BE8081321.MLG`
- from `~/seismo-relay/example-events/ach-vs-manual/`: `BE11529.MLG`, `BE115292.MLG`
- from `~/seismo-relay/example-events/10-26-26/`: `BE94412.MLG`
Then `git add -f tests/fixtures/mlg-11-9-26`. Expected: 12 files, about 14 KB.
- [ ] **Step 2: Write the failing tests** in `tests/test_mlg_file.py`
Use `FIX = Path(__file__).parent / "fixtures" / "mlg-11-9-26"` and
`dt = datetime.datetime`.
```python
def test_crc_matches_the_micromate_rule():
from micromate.setup_block import _crc16_aug_ccitt
assert crc16_aug_ccitt(b"123456789") == _crc16_aug_ccitt(b"123456789") == 0xE5CC
def test_every_fixture_record_passes_its_checksum():
for p in FIX.glob("*.MLG"):
assert parse_mlg(p.read_bytes()).crc_failures == [], p.name
def test_closed_records(): # BE128443065
m = read_mlg(FIX / "BE128443065.MLG")
assert m.serial == "BE12844" and len(m.records) == 2
r1, r2 = m.records
assert (r1.index, r1.start, r1.stop, r1.flags, r1.trigger_source) == (
1, dt(2026, 9, 5, 18, 47, 26), dt(2026, 9, 5, 20, 0, 0), 0x0010, 0)
assert r1.description == "Timer Stop"
assert r1.trigger_level == "Geo: 0.0500 in/s Mic: 125.0 dB(L)"
assert (r2.start, r2.stop, r2.description) == (
dt(2026, 9, 6, 6, 0, 13), dt(2026, 9, 6, 18, 45, 0), "Modem Exit")
def test_monitoring_started_and_an_event(): # BE128443067
m = read_mlg(FIX / "BE128443067.MLG")
start, ev = m.records[1], m.records[2]
assert start.is_start and start.stop is None and start.description == "Monitoring started"
assert start.trigger_level == "Geo: 0.0500 in/s Mic: 125.0 dB(L)"
assert (ev.flags, ev.trigger_source, ev.description) == (0x0001, 0x0001, "Event Recorded")
assert ev.event_time == dt(2026, 9, 8, 13, 38, 22)
assert ev.text == "Geo: 0.0500 in/s Mic: 125.0 dB(L)\rTran: 0.0500 in/s"
assert ev.trigger_level == "Geo: 0.0500 in/s Mic: 125.0 dB(L)"
def test_histogram_with_a_waveform_event(): # BE8081.MLG
r = read_mlg(FIX / "BE8081.MLG").records
assert (r[1].flags, r[1].trigger_source, r[1].description) == (
0x0021, 0x0400, "Event Recorded Modem Exit")
assert r[1].trigger_level == "Histogram"
assert (r[2].trigger_source, r[2].trigger_level) == (0x0002, "Geo: 0.300 in/s")
def test_trigger_level_with_or_without_a_space_before_the_colon():
a = read_mlg(FIX / "BE11529.MLG").records[0]
b = read_mlg(FIX / "BE115292.MLG").records[0]
assert a.text == "Trigger Level: Histogram" and b.text == "Trigger Level : Histogram"
assert a.trigger_level == b.trigger_level == "Histogram"
def test_empty_file():
m = read_mlg(FIX / "BE6907751.MLG")
assert m.serial is None and m.records == [] and m.empty
def test_a_flipped_byte_fails_only_its_record():
data = bytearray((FIX / "BE128443065.MLG").read_bytes())
data[18 + 292 + 40] ^= 0xFF # inside record 1's text
m = parse_mlg(bytes(data))
assert m.crc_failures == [1]
assert m.records[0].crc_ok is False and m.records[1].crc_ok is True
@pytest.mark.parametrize("mangle", [
lambda d: d[:-1], # not 18 + 292·n
lambda d: b"\x00" + d[1:], # wrong prefix
lambda d: d[:18] + b"\x23" + d[19:], # header length field not 290
])
def test_structure_errors_raise(mangle):
with pytest.raises(MlgFormatError):
parse_mlg(mangle((FIX / "BE128443065.MLG").read_bytes()))
```
- [ ] **Step 3: Run them to verify they fail**
Run: `~/seismo-relay/.venv/bin/python -m pytest tests/test_mlg_file.py -q`
Expected: collection error, `ModuleNotFoundError: minimateplus.crc`.
- [ ] **Step 4: Implement**
**The shared CRC.** `crc16_aug_ccitt` uses the same bitwise loop as `setup_block`. Point
`setup_block._crc16_aug_ccitt` at it, keeping the name, since its tests import it.
**Timestamps.** A timestamp is `day, month, year LE (2 bytes), 0, hour, minute, second`, and
all-zero means `None`.
**`parse_mlg` raises `MlgFormatError`, naming the record, when:**
- `len < 18`, or the prefix differs
- `(len - 18) % 292 != 0`
- any record's length field is not 290
- record 0's id is not `0e a0`, or a later record's id is not `0e 80`
- a start time cannot be decoded
**A checksum failure does not raise.** It only sets `crc_ok=False`.
**The text:**
- If `text_raw[0] == 0x08`, then `event_time` is `text_raw[1:9]` and the text starts at
`text_raw[9]`.
- `text` is the bytes up to the first NUL, latin-1.
- `trigger_level` is `text`'s first line (split on `\r`), with a leading `Trigger Level :` or
`Trigger Level:` removed and stripped. An empty result is `None`.
**`description`** is `"Monitoring started"` for `is_start`. Otherwise it is
`event_file_io.monitor_log_description(flags).strip()`.
**The header record** gives `MlgFile.serial` (`record[24:34]`, NUL-stripped ASCII).
- [ ] **Step 5: Run the tests, then the whole suite**
Run: `~/seismo-relay/.venv/bin/python -m pytest tests/test_mlg_file.py tests/test_micromate_setup.py -q`
Expected: all pass.
Then the full suite. Expected: `0 failed`.
- [ ] **Step 6: Commit**
```bash
git add minimateplus/crc.py minimateplus/mlg_file.py minimateplus/models.py micromate/setup_block.py tests/test_mlg_file.py
git commit -m "feat(mlg): read Blastware .MLG files, every record's checksum verified"
```
---
### Task 2: The writer, and the old MLG code retired
**Files:**
- Modify: `minimateplus/mlg_file.py` (add the writer)
- Modify: `minimateplus/blastware_file.py`:
- delete `_build_mlg_header`, `_build_mlg_record`, the old `write_mlg`, the `read_mlg` stub,
`_MLG_*` and `MLG_FLAGS_*`
- the module docstring's MLG sections become one line pointing at `minimateplus/mlg_file.py`
- ⚠ **Do not re-export from `blastware_file`.** `event_file_io` imports `blastware_file`
and `mlg_file` imports `event_file_io`, so a re-export makes an import cycle. Nothing outside
`blastware_file.py` uses the old names (checked 2026-11-13).
- Test: `tests/test_mlg_file.py`
**Interfaces:**
- Consumes: `MlgFile`, `MlgRecord` (Task 1)
- Produces:
- `mlg_file.mlg_bytes(mlg: MlgFile) -> bytes`
- `mlg_file.write_mlg(mlg: MlgFile, path) -> None`
- [ ] **Step 1: Write the failing tests**
```python
@pytest.mark.parametrize("name", sorted(p.name for p in FIX.glob("*.MLG")))
def test_rebuilds_every_fixture_byte_for_byte(name):
raw = (FIX / name).read_bytes()
assert mlg_bytes(parse_mlg(raw)) == raw
def test_old_mlg_code_is_gone():
import minimateplus.blastware_file as bw
assert not hasattr(bw, "read_mlg") and not hasattr(bw, "MLG_FLAGS_TRIGGER")
```
- [ ] **Step 2: Run them to verify they fail** (`ImportError: mlg_bytes`)
- [ ] **Step 3: Implement `mlg_bytes`**
Write the prefix, then for a non-empty file the header record:
- length, id `0e a0`, zeros, the serial at `[24:34]`, zeros, then the CRC
Every other byte of the header record is zero on all 1,273 DL2 files (measured).
Then each log record, from its fields:
- length, id `0e 80`, both times, flags and source LE, the serial
- `text_raw`, then `00 00`, then the CRC
An empty `MlgFile` is the prefix alone. Confirm nothing else imports the deleted names:
`grep -rn "MLG_FLAGS_\|_build_mlg\|_MLG_" --include=*.py .`
- [ ] **Step 4: Run the tests and the full suite.** Expected: 12 rebuilds pass; `0 failed`.
- [ ] **Step 5: Commit**
`git commit -m "feat(mlg): write .MLG files as Blastware does; retire the old writer"`
---
### Task 3: Storage
**Files:**
- Modify: `sfm/database.py`: the two tables appended to `_SCHEMA`, and the methods below.
- The docstring's table list gains both tables.
- No migration: `CREATE … IF NOT EXISTS` runs on every start.
- Modify: `sfm/waveform_store.py`: add `save_mlg`
- Test: `tests/test_mlg_storage.py`
**Interfaces:**
- Consumes: `MlgRecord` (Task 1)
- Produces:
- `WaveformStore.save_mlg(serial: Optional[str], file_name: str, data: bytes) -> str`.
- Writes `<root>/<serial or "_unresolved">/mlg/<file_name>` and returns that path
relative to the root (posix).
- If that path already holds different bytes, it uses `<stem>.<sha256[:8]><suffix>`.
- If it holds the same bytes, it reuses the path.
- `SeismoDb.mlg_file_exists(file_name: str, sha256: str) -> bool`
- `SeismoDb.insert_mlg(*, serial, file_name, sha256, size, empty, call_in, file_mtime, stored_path, records) -> tuple[Optional[str], int, int]`
- One transaction; returns `(file_id, inserted, skipped)`.
- Returns `(None, 0, 0)` when `(file_name, sha256)` already exists.
- `SeismoDb.query_mlg_records(serial: str, from_dt=None, to_dt=None) -> list[dict]`:
- ascending by `start_time`, then `seq`
- keys: `id, serial, start_time, stop_time, flags, trigger_source, text, trigger_level,
event_time, file_id, seq`
- `SeismoDb.query_mlg_files(serial: str) -> list[dict]`:
- ascending by `COALESCE(file_mtime, received_at)`
- keys: `id, serial, file_name, sha256, size, record_count, empty, call_in, file_mtime,
received_at, stored_path`
- `SeismoDb.get_mlg_file(file_id: str) -> Optional[dict]`
- `SeismoDb.known_serials() -> set[str]`: distinct non-null serials from `events`,
`mlg_files` and `mlg_records`
Schema:
```sql
CREATE TABLE IF NOT EXISTS mlg_files (
id TEXT PRIMARY KEY, serial TEXT, file_name TEXT NOT NULL, sha256 TEXT NOT NULL,
size INTEGER NOT NULL, record_count INTEGER NOT NULL, empty INTEGER NOT NULL,
call_in INTEGER NOT NULL DEFAULT 1, file_mtime TEXT,
received_at TEXT NOT NULL DEFAULT (strftime('%Y-%m-%dT%H:%M:%SZ', 'now')),
stored_path TEXT, UNIQUE(file_name, sha256));
CREATE TABLE IF NOT EXISTS mlg_records (
id TEXT PRIMARY KEY, serial TEXT NOT NULL, start_time TEXT NOT NULL, stop_time TEXT,
flags INTEGER NOT NULL, trigger_source INTEGER NOT NULL, text TEXT, trigger_level TEXT,
event_time TEXT, file_id TEXT NOT NULL REFERENCES mlg_files(id), seq INTEGER NOT NULL);
CREATE UNIQUE INDEX IF NOT EXISTS ux_mlg_records_identity
ON mlg_records(serial, start_time, COALESCE(stop_time, ''), flags, trigger_source);
CREATE INDEX IF NOT EXISTS idx_mlg_files_serial ON mlg_files(serial);
```
- [ ] **Step 1: Write the failing tests**
- `test_insert_and_query_round_trip`: insert BE128443067's records; query returns 3 rows in
start order, with the open record's `stop_time` None.
- `test_same_file_twice_is_a_duplicate`: the second `insert_mlg` returns `(None, 0, 0)` and
there is still one file row.
- `test_open_record_is_stored_once`: insert the same `MlgFile` under two names (as a cable
download would arrive). The second returns `inserted == 0, skipped == 3`.
- `test_records_differing_only_in_text_are_the_same_record`: `BE11529.MLG`, then
`BE115292.MLG`. The second is `(id, 0, 3)`.
- `test_known_serials`, and `test_save_mlg_keeps_both_when_names_collide`: same name,
different bytes, two paths.
- [ ] **Step 2: Run them to verify they fail** (`AttributeError: insert_mlg`)
- [ ] **Step 3: Implement** the schema and the methods above. `record_count` is
`len(records)`.
- [ ] **Step 4: Run the tests and the full suite.** Expected: pass; `0 failed`.
- [ ] **Step 5: Commit**
`git commit -m "feat(mlg): store .MLG files and records, each record once"`
---
### Task 4: Ingest
**Files:**
- Create: `sfm/mlg_ingest.py`, `tests/test_mlg_ingest.py`
**Interfaces:**
- Consumes: `parse_mlg`, `MlgFormatError` (Task 1); `insert_mlg`, `mlg_file_exists`,
`known_serials`, `save_mlg` (Task 3)
- Produces:
- `resolve_serial(file_name: str, header_serial: Optional[str], hint: Optional[str], known: set[str]) -> Optional[str]`
- `ingest_mlg(db, store, file_name: str, data: bytes, *, serial_hint=None, file_mtime: Optional[datetime]=None, call_in: bool=True) -> dict`
Keys: `filename, status ("ok" | "duplicate" | "error"), detail, serial, serial_unresolved,
empty, records, inserted, skipped, file_id`.
**Rules:**
- **Serial:** the header serial wins. Otherwise the hint. Otherwise the longest known serial
that the name starts with (case-insensitive), as long as only digits follow it before
`.MLG`. Otherwise `None`.
- **Order of work:**
1. parse
2. a `MlgFormatError`, or any checksum failure, is `status "error"`, with `detail` naming
the record (e.g. `"record 1 fails its checksum"`); nothing is written
3. `mlg_file_exists` gives `"duplicate"`
4. `save_mlg`
5. `insert_mlg`
- [ ] **Step 1: Write the failing tests** (a tmp `SeismoDb` and `WaveformStore`, as
`tests/test_db_snapshot_endpoints.py::_client` builds them)
- `test_ingest_ok`: BE128443067 gives `status "ok"`, serial `BE12844`, `records 3`,
`inserted 3`. The file exists in the store under `BE12844/mlg/`.
- `test_ingest_twice_is_duplicate`
- `test_corrupted_file_stores_nothing`: flip byte `18+292+40`. Expect `"error"`, `"record 1"`
in `detail`, no `mlg_files` row, and no `mlg/` directory in the store.
- `test_truncated_file_is_an_error`
- `test_empty_file_takes_known_serial`: ingest `BE6907750` then `BE6907751`. The second is
`serial "BE6907"`, `empty True`.
- `test_empty_file_without_known_serial_is_unresolved`: serial `None`,
`serial_unresolved True`, stored under `_unresolved/mlg/`.
- `test_empty_file_takes_the_longest_known_serial`:
- `resolve_serial("BE11010304.MLG", None, None, {"BE1101", "BE11010"}) == "BE11010"`
- `resolve_serial("XY123.MLG", None, None, {"BE1101"}) is None`
- `resolve_serial("BE6907751.MLG", "BE12844", "BE6907", {"BE6907"}) == "BE12844"` (the
header wins)
- `test_file_mtime_and_call_in_are_stored`
- [ ] **Step 2: Run them to verify they fail**
- [ ] **Step 3: Implement `sfm/mlg_ingest.py`**
- [ ] **Step 4: Run the tests and the full suite.** Expected: pass; `0 failed`.
- [ ] **Step 5: Commit**
`git commit -m "feat(mlg): ingest one .MLG: verify, resolve the serial, keep the original"`
---
### Task 5: The timeline
**Files:**
- Create: `sfm/mlg_timeline.py`, `tests/test_mlg_timeline.py`
**Interfaces:**
- Consumes: rows from `query_mlg_records` and `query_mlg_files` (Task 3)
- Produces:
- `build_timeline(records: list[dict], files: list[dict]) -> dict`, with keys `sessions`,
`gaps`, `clock_steps`, `call_ins`. All times are ISO strings.
- **a session:** `start, stop, end_after, end_before, ended_by, kind ("histogram" |
"monitoring"), trigger_level, running_at_last_report, events`
- **an event:** `start, stop, trigger_source, trigger_level, description`
- **a gap:** `start, stop, minutes, meaning`
- **a clock step:** `previous_stop, next_start, minutes` (negative)
- **a call-in:** `kind ("delivered" | "no_file" | "nothing_new"), unit_time, file_time,
file_name`
- `monitoring_at(timeline: dict, at: datetime) -> dict`, with keys `status ("monitoring" |
"not_monitoring" | "unknown"), ambiguous, sessions, gap, trigger_level, reason`
**Rules.** These are the spec's §4 rules, made exact.
- **Sort:** records by `(start_time, 0 if flags == 0xFFFF else 1, seq)`.
- **Record kinds:**
- **start:** `flags == 0xFFFF`
- **histogram:** `flags & 1` and `trigger_source == 0x0400`
- **event:** `flags & 1` and any other non-zero source
- **closed:** everything else
- **Building sessions, walking the sorted records:**
- **A start record opens a pending session.** Close any pending one first, with
`end_after` = its last event's stop (or its own start) and `end_before` = this start.
- **A histogram record joins the pending session** when its start is ≤ 2 s after the pending
start, giving the session `stop` and `kind "histogram"`. Otherwise it is a session of its
own.
- **An event record:**
- joins the last session if its start lies within that session's `[start, stop]`
- otherwise it joins the pending session
- an event carrying an end bit closes a pending (non-histogram) session at its stop
- with no session to join, it opens one at its own start
- **A closed record** first closes any pending session (as above, `end_before` = its start),
then is a session `[start, stop]`.
- **A session still pending at the end** has `running_at_last_report True` and
`end_after` = its last event's stop, or its start.
- **`ended_by`** is `monitor_log_description(flags & ~1).strip()` of the record that set
`stop`, or `None`. `trigger_level` is the start record's, else the stop record's.
- **Gaps:** from a session's end (`stop`, else `end_after`) to the next session's start.
- If the next start is earlier than that end, it is a clock step, not a gap.
- The meaning comes from `ended_by`:
- Modem Exit: "call-in"
- Timer Stop: "scheduled off"
- Battery Low Exit: "lost power"
- Keyboard Exit and Remote Exit: "stopped by a person"
- Memory Full Exit: "memory full"
- anything else: "unknown"
- **Call-ins**, per file in `query_mlg_files` order (`file_time` = `file_mtime`, else
`received_at`):
- **An empty file** gives `nothing_new`.
- **A `call_in` file with records** gives `delivered`, with `unit_time` = the stop of the
file's last record (by `seq`). Each Modem Exit (`flags & 0x20`, not a start) that is not
the file's last record gives `no_file`, with `unit_time` = its stop and `file_time` None.
- **Non-call-in files** give nothing.
- **`monitoring_at`:**
- **monitoring:** `start ≤ at ≤ stop`, or `≤ end_after` when the stop is unknown. Two or more
matches set `ambiguous True`.
- **unknown:** inside an unknown end window, or after `end_after` of a session running at the
last report.
- **not_monitoring:** inside a gap, with the gap.
- **unknown:** anything else, including no data.
- [ ] **Step 1: Write the failing tests.** Ingest fixtures into a tmp DB with explicit
`file_mtime` values, then call `build_timeline(db.query_mlg_records(s), db.query_mlg_files(s))`.
- `test_sessions_gaps_and_an_event_session` (BE128443067 + 068):
- three sessions: `09-07 18:47:27 → 20:00:00 "Timer Stop"`; `09-08 06:00:13`, stop None,
`end_after 13:38:25`, `end_before 13:41:16`, 1 event; `13:41:16 → 18:45:00 "Modem Exit"`
- gaps: `"scheduled off"`, `minutes ≈ 600.217`; then `"unknown"`, `≈ 2.85`
- `test_monitoring_at`, on the same data:
- `09-08 10:00` is `monitoring`, trigger level `"Geo: 0.0500 in/s Mic: 125.0 dB(L)"`
- `09-08 13:40:00` is `unknown`
- `09-07 23:00` is `not_monitoring` with meaning `"scheduled off"`
- `2027-01-01` is `unknown`
- `test_monitoring_at_boundaries_are_inclusive`: `09-07 18:47:27` and `09-07 20:00:00` are
both `monitoring`.
- `test_clock_step_back_is_not_a_negative_gap` (BE128443155 + 156):
- no gap with negative minutes
- one clock step: `previous_stop 2026-11-01T18:45:00`, `next_start 2026-11-01T17:47:25`,
`minutes ≈ -57.58`
- `monitoring_at(11-01 18:00)` is `monitoring`, `ambiguous True`, 2 sessions
- `test_weekend_battery_outage_and_missed_calls` (BE8081321 alone):
- sessions start at `04-12 17:17:59` (histogram, from the start record),
`04-12 18:38:14`, `04-13 07:05:15` ("Battery Low Exit") and `04-15 12:47:05`
- the gap `04-13 10:47:15 → 04-15 12:47:05` is `"lost power"`, `minutes ≈ 2999.83`
- two `"call-in"` gaps of `≈ 5.23`
- call-ins: `no_file` at `2019-04-12T18:33:00`, `no_file` at `2019-04-13T07:00:01`,
`delivered` at `2019-04-15T17:15:00`, with `file_name "BE8081321.MLG"`
- `monitoring_at(2019-04-14 12:00)` is `not_monitoring`, `"lost power"`
- `test_histogram_session_keeps_its_waveform_event` (BE8081.MLG):
- one session `2018-02-16 15:15:31 → 15:15:49`, `kind "histogram"`,
`trigger_level "Histogram"`
- one event with `trigger_source 2` and `trigger_level "Geo: 0.300 in/s"`
- `test_event_with_an_end_bit_inside_a_histogram` (BE94412):
- the histogram session `16:06:34 → 16:07:21` keeps its stop and `"Keyboard Exit"`
- it holds the Memory Full event
- the `17:00:36` histogram is a session of its own
- `test_call_in_kinds` (BE6907750 + 751): `no_file` at `2026-08-22T18:30:00`, `delivered` at
`2026-08-23T18:30:00`, then `nothing_new`.
- [ ] **Step 2: Run them to verify they fail**
- [ ] **Step 3: Implement `sfm/mlg_timeline.py`** (pure: no DB, no I/O)
- [ ] **Step 4: Run the tests and the full suite.** Expected: pass; `0 failed`.
- [ ] **Step 5: Commit**
`git commit -m "feat(mlg): each unit's monitoring timeline, and was it monitoring at T"`
---
### Task 6: Routes
**Files:**
- Modify: `sfm/server.py`: the routes go after `db_import_idf_file`
- Create: `tests/test_mlg_routes.py`
**Interfaces:**
- Consumes: `ingest_mlg` (Task 4); `build_timeline`, `monitoring_at` (Task 5); Task 3's queries
- Produces:
- `POST /db/import/mlg_file` → `db_import_mlg_file(files: list[UploadFile] = File(...), serial: Optional[str] = Query(None), call_in: bool = Query(True), mtimes: Optional[str] = Form(None))`.
`mtimes` is JSON `{filename: unix_seconds_utc}`. Returns `{"count", "results": [ingest
dicts]}`.
- `GET /db/units/{serial}/timeline?from_dt=&to_dt=` → `db_unit_timeline(...)`: the full
timeline, with sessions, gaps and call-ins filtered to those overlapping the window.
- `GET /db/units/{serial}/monitoring_at?at=` → `db_unit_monitoring_at(...)`
- `GET /db/mlg_records?serial=&from_dt=&to_dt=` → `db_mlg_records(...)`
- `GET /db/mlg_files/{file_id}` → `db_mlg_file(...)`: the original bytes as a `FileResponse`
with the original `file_name`; 404 if unknown.
- [ ] **Step 1: Write the failing tests.** Set up as `_client` does (monkeypatch `srv._db` and
`srv._store`). Call the route functions directly: `asyncio.run(...)` for the import, with
`UploadFile(file=io.BytesIO(data), filename=name)`.
- `test_import_route_stores_good_file_and_refuses_bad_one`:
- two files, BE128443065 and a corrupted copy named `BE128443099.MLG`
- results: `["ok", "error"]`
- one `mlg_files` row; only the good file under the store's `mlg/`
- `test_import_route_reads_mtimes`: `mtimes='{"BE128443065.MLG": 1788734760}'` stores
`file_mtime` `2026-09-06T22:46:00+00:00`.
- `test_timeline_and_monitoring_at_routes`, with BE8081321 imported: the timeline has 4
sessions, and `monitoring_at` at `2019-04-14T12:00:00` is `not_monitoring`.
- `test_timeline_routes_for_unknown_serial`: `BE0000` gives empty `sessions`, `gaps` and
`call_ins`, and `monitoring_at` is `unknown`.
- `test_mlg_file_route_returns_original_bytes`, and a 404 for an unknown id.
- [ ] **Step 2: Run them to verify they fail**
- [ ] **Step 3: Implement the routes.** They stay thin: parse the query, call Tasks 3–5.
- [ ] **Step 4: Run the tests and the full suite.** Expected: pass; `0 failed`.
- [ ] **Step 5: Commit**
`git commit -m "feat(mlg): /db routes: import .MLG, a unit's timeline, monitoring at T"`
---
### Task 7: Bulk import and the cross-check
**Files:**
- Create: `scripts/import_mlg_dir.py`, `scratch/check_mlg_vs_events.py`,
`tests/test_import_mlg_dir.py`
**Interfaces:**
- Consumes: `ingest_mlg` (Task 4), `parse_mlg` (Task 1), `crc16_aug_ccitt` (Task 1)
- Produces:
- **`scripts/import_mlg_dir.py <dir> --db-path P --store-root S [--dry-run] [--not-call-in]`**
- `main(argv) -> int`, following `scripts/backfill_event_shape.py`
- walks `*.MLG` (case-insensitive) recursively
- **two passes:** files with records first, then the empty ones, each oldest file time
first. Every unit's serial is then known before its empty files arrive, whatever the
folder order.
- `file_mtime` from `os.stat` as UTC
- prints counts: files, ok, duplicate, error, empty, unresolved, inserted, skipped
- dry run: parse and checksums only, nothing written
- **`scratch/check_mlg_vs_events.py <mlg dir> <event dir>`**
- matches every non-start record with the Event Recorded bit to an event file by
`(serial, stop, flag word, trigger source)`
- an event file's serial number comes from its name, via
`sfm.waveform_store._serial_number_from_bw_filename`, compared with the MLG serial's
digits
- only event files inside each serial's MLG period count (its first record's start to its
last record's stop). DL2 holds years of event files from before the `.MLG`s.
- reads each event file's footer straight from its last 28 bytes: `00 1a 0e 08`, both times
with a big-endian year, flag word and source BE. It checks the footer's CRC with
`crc16_aug_ccitt` too.
- prints matched / record-only / file-only per serial, with up to 5 examples each
- [ ] **Step 1: Write the failing test.** `test_import_dir_counts`:
- copy the fixture dir to `tmp_path`
- the dry run prints `files 12`, writes no DB file and returns 0
- a real run imports 12 files with 0 errors, and a second run reports 12 duplicates
- [ ] **Step 2: Run it to verify it fails**
- [ ] **Step 3: Implement both tools**
- [ ] **Step 4: Run the tests and the full suite.** Expected: pass; `0 failed`.
- [ ] **Step 5: Run both tools on the real data, on the dev box only**
```bash
~/seismo-relay/.venv/bin/python scripts/import_mlg_dir.py ~/dl2-archive/mlg --db-path /tmp/claude-1000/mlg-check.db --store-root /tmp/claude-1000/mlg-check-store
~/seismo-relay/.venv/bin/python scratch/check_mlg_vs_events.py ~/dl2-archive/mlg ~/dl2-archive/files
```
Expected:
- 1,273 files, 0 errors, 231 empty, 0 unresolved
- BE8081: 785 matched, 0 record-only, 0 file-only
- BE6907: 6 matched, 5 record-only, 0 file-only
- BE12844: 19 matched, 37 record-only, 0 file-only
- every record-only one stops after 2026-08-25, where the DL2 copy ends
Put the numbers in the commit message.
- [ ] **Step 6: Commit**
`git commit -m "feat(mlg): bulk import, and a cross-check against the event files"`
---
### Task 8: Documentation
**Files:**
- Modify: `docs/instantel_protocol_reference.md`:
- D.4 to D.4.3 rewritten from the spec's "What was measured", each claim graded
- the old D.4.2 table kept under a ⚠ RETRACTED banner (its CRC position, BE timestamps
and flag table)
- a row in the Changelog table at the top
- Modify: `CLAUDE.md`:
- the "SFM REST API" `/db` list gains the five routes
- one line under "Where things stand" pointing at the spec
- Modify: `docs/superpowers/specs/2026-11-09-mlg-unit-timeline-design.md` §8: the footer CRC
note becomes "recorded on dev, `8544e9c`"
- [ ] **Step 1: Edit the three files**
- [ ] **Step 2: Run `tests/test_line_endings.py` and the full suite.** Expected: `0 failed`.
- [ ] **Step 3: Commit**
`git commit -m "docs: the .MLG format measured (reference D.4), and the new /db routes"`
File diff suppressed because it is too large. Load diff
@@ -1,268 +0,0 @@
# Series 3 decode checker — design
**Date:** 2026-10-29 · **Branch:** `feat/s3-decode-checker` · **Status:** design
## Why this exists
SFM is meant to replace Blastware. Today, when a Series 3 event arrives with
Blastware's ASCII report, SFM takes many of its values from the report: ZC
frequency, acceleration, the sensor check and so on. Two of the four ways
events will reach SFM, its own serial/modem download and its future call-in
server, never have a report. So SFM must produce **everything Blastware
reports, from the event file alone**, and we need proof that it does.
The checker is that proof, and the to-do list for getting there. It decodes
each event file the way SFM ingest does, with no report, and compares every
field with Blastware's own report of the same event. Then it says what
matches, what doesn't, and what SFM can't produce yet.
It is the first of four pieces, agreed with Brian on 2026-10-29:
1. **This checker.**
2. Completing SFM's file-only decode, one field group at a time, each slice
done when the checker shows it matching. Slice 1, the setup fields and
notes (#44/#45), merged to dev as `42fe35f`.
3. Flipping ingest to file-only. Reports are kept for checking only. This
happens only when piece 2 leaves no blanks and the checker proves it.
Prod keeps its current behaviour until then.
4. The watcher: it forwards the XML report while we verify, then stops
forwarding reports.
## The reference: Blastware's XML event reports
Every Blastware ACH machine keeps, in `Sent/`, a full XML event report for each
event: `<stem>_<ext>_XML.XML` next to the binary `<stem>.<ext>`. DL2's backup
holds **70,042 of them for Series 3 events, from 2016 to 2026**. Its ASCII
reports, by contrast, cover only 2025–26.
Local copies on the dev box (`tmi-dev`, 10.0.0.44):
| what | where | count |
|---|---|---|
| event binaries (Series 3) | `~/dl2-archive/files/` (root + `Sent/` mirror, dedupe by basename) | 70,112 distinct |
| XML reports | `~/dl2-archive/xml/` (flat) | 75,958 = 70,042 Series 3 + 5,916 Micromate (`UM…_IDF?_XML.XML`) |
| ASCII reports | `~/dl2-archive/files/` | 14,338 (2025–26 only) |
What the Series 3 XML contains (surveyed across all 75,958 on 2026-10-29):
- **Identity:** `EventType` (`Full Waveform` 6,524, `Full Histogram`
63,518), `SerialNumber`, `Version` (`V 10.72-8.17 MiniMate Plus` or
`… BlastMate III`), `FileName`.
- **Time:** waveform `EventDate`/`EventTime`; histogram
`HistogramStart*`/`HistogramStop*`.
- **Setup:** `Channels`, `Trigger`, `GeoTriggerLevel`, `MicTriggerLevel`,
`Pre-triggerLength`, `RecordTime`, `RecordStopMode` (only `Fixed` occurs),
`SampleRate`, `IntervalSize` (2 s / 5 s / 15 s / 1 min / 5 min),
`NumberofIntervals`, `GeoRange` (10.000: 75,923; 1.250: 35), `Units` (`in/s
and dB(L)` / `psi(L)` / `dB(A)` / `in/s`), `Microphone` (weighting).
- **Unit:** `BatteryLevel`, `Calibration` (date + by whom), `MicCalibration`.
- **Notes:** `JobNumber`, then up to four user notes. Each is tagged with its
operator-editable label (`Project`, `Location`, `Seis.Loc`, `SeisLocation`,
`SeismographLoc`, `Company`, `General`, …), and empty notes are omitted.
They sit between the top-level `</Units>` and `<GeoRange>`.
- **Results:** per channel `PPV`, `ZCFreq`, `TimeofPeak`, `PeakAcceleration`,
`PeakDisplacement` (waveform) or `PeakDate`/`PeakTime` (histogram);
`PeakVectorSum` with its time; mic `PSPL`, time, `ZCFreq` (dB(A)
histograms carry `MicA*` fields instead).
- **Sensor check:** per geophone `TestFreq`, `TestRatio`, `TestResults`; mic
`TestFreq`, `TestAmplitude`, `TestResults`.
- **`MonitorLog`:** the session's start, stop and status text.
- **Data:** waveform `WaveformDataChannels/Data/Row/Cell` (4 cells per
sample: Tran, Vert, Long in in/s, MicL in the event's mic units); histogram
`HistogramDataIntervals` (a `Time` and a 10-cell `Row` per interval:
Tran/Vert/Long peak + freq, geo PVS, MicL psi, dB and freq).
Value forms the parser must handle: numbers with units in the text (`6.7
Volts`, `7.6 Hz.`, `3.0 sec.`, `-0.250 sec`); `&gt;100` (ZC frequency above
range; 71,823 files), `N/A` (37,293 files), `OORANGE` (59 files: the channel
clipped), `Check` (2,193 files), and XML entities. Two `_XML.XML` details
matter:
- Blastware prints each number to a fixed number of decimals and **rounds
halves away from zero** (−0.0625 s prints as −0.063).
- The small `<stem>_<ext>.XML` summary next to it uses **decimal commas**.
It is not the reference; the `_XML.XML` is.
## Goals
- For every Series 3 event file with an XML report, compare **every field the
XML carries**, plus every waveform sample and every histogram interval,
against SFM's file-only decode.
- Give each comparison one verdict: **match**, **mismatch**, **SFM blank**
(SFM produced nothing), **accepted difference** (covered by a written
carve-out), **no reference** (the XML lacks the field), or **error** (the
decode or parse failed).
- Produce two outputs:
- **A short summary for Brian:** per field, the counts of each verdict and
how far we are from done.
- **A detailed report for Claude** that groups failures by what the failing
events share, so 17,000 mismatches read as "one bug on 2048 sps
histograms". It gives example files with Blastware's value and SFM's, and
a one-line command to re-run a single event.
- **Run again and again.** Each run is compared with the previous one, so a
fix shows as numbers moving, and anything that used to match and stops is
called out.
- Keep the comparison as library code, so ingest can later run it on one
event as it arrives (piece 3/4).
## What counts as "SFM's side"
The SFM side is **what SFM produces from the event's bytes alone**:
- **The `Event` that `decode_blastware_bytes` returns when given the bytes and
no filename.**
- SFM's own download and call-in paths never have a Blastware name.
- Today the event type comes only from the filename's extension, so every
histogram decodes as "Waveform". The checker reports that as it is: a
mismatch until the decoder reads the type from the file (#41). It must
not borrow the name to make it match.
- **Anything else SFM reads from those bytes outside the decoder**, such as the
serial.
- Ingest's `sfm/waveform_store._serial_from_bw_bytes` uses the filename to
validate what it finds.
- Whatever SFM can't get from the bytes alone is "SFM blank".
- **Values the codec computes but never puts on the `Event`** count as SFM
blank until they are wired through (piece 2). For example, histogram
half-periods in `histogram_codec.decode_histogram_body_full` give the
per-interval frequency.
- **SFM's assumptions included.**
- SFM cannot yet read the geophone range from the file, and assumes Normal
(10 in/s): `_peaks_from_samples` does, and ingest writes `.h5` with
`geo_range="normal"`.
- The checker compares what SFM actually produces under that assumption.
The range field itself is SFM blank.
- So the 35 events recorded on the 1.250 in/s range show as 8× mismatches,
not blanks. Example: `T438L713.QP0W` gives PPV 0.015/0.02/0.015 against
Blastware's 0.002.
- The range is never taken from the reference.
So the comparison takes an SFM-side record plus the parsed reference. The
runner assembles that record from the decoder and any SFM helpers. The
comparison itself stays pure codec-library code; only the runner (a lab tool)
may import from `sfm/`.
## The rule for disagreements (decided by Brian)
**Every mismatch is an SFM bug until shown otherwise.** A mismatch becomes an
"accepted difference" only through a written carve-out that names the fields
it covers and the rule it applies. Its evidence must not rest on SFM's own
output: Blastware contradicting itself, the instrument's own data (counts
in the file, the unit's embedded record), a third source (another instrument,
a known signal), or Instantel documentation. Each run reports how many events
each carve-out covers.
The carve-out list starts with one entry, already proven in
`scratch/verify_against_ascii.py`: **saturation**. On a clipped channel,
Blastware clamps its numbers to the range maximum and writes `OORANGE`, while
the file holds counts past full scale. Rounding to Blastware's printed
precision is a comparison rule, not a carve-out.
## Non-goals
- **Series 4 / Micromate.** Thor's IDF decode has its own CSV-based check, and
the 5,916 Micromate XMLs are noted for a later Series 4 checker.
- **Changing what SFM decodes.** The checker reports gaps; filling them is
piece 2.
- **Wiring the check into ingest, the watcher or Terra-View.** That's pieces
3/4. Nothing on prod changes.
- **ASCII reports as a reference.** The XML covers every year, including the
2025–26 events that have ASCII. The reference is parsed into a shape another
report format could fill later, but no ASCII adapter is built now.
## Anti-goals (would make it a failure even if it runs)
- **Comparing SFM with Blastware's own numbers.** The SFM side must come only
from the event file, through `decode_blastware_bytes` with no report
overlay. Nothing from the XML or ASCII report may reach the SFM side.
- **Hiding mismatches:** a carve-out without evidence, a tolerance looser
than Blastware's printed precision, or blanks counted as matches.
- **Wrong conversions:** counts converted to in/s with a range or scale that
came from the reference rather than the file. If SFM can't read the range
from the file yet, that is a gap to report, not something to borrow.
- **A report that only says "N mismatches"** without grouping and examples.
It must be usable to find the cause.
- **A full run so slow it isn't run after every fix.**
## Constraints
- **Hardware:** runs on the dev box (4 cores, ~17 GB free disk after the
22 GB XML copy; Brian can add space).
- **Read-only:** it never writes to the corpus folders and needs no network.
- **Speed:** a full run over all 70,042 events in **under an hour**. A
partial run (by serial, year, event type or field group, or a random sample)
in **a few minutes**. The setup/notes harness covering ~6 fields took ~4
minutes with 4 processes. Samples and intervals add parsing 22 GB of XML.
The standard library parses at ~45 MB/s per core (`lxml` is not
installed), which fits the budget.
- **Codec library purity (ADR 0003):** the codec library stays pure. Bench and
lab tools stay out of the production image.
- **Results contain customer project names**, so run output is kept outside
the repo and never committed.
## What's decided, and by whom
**Brian:**
- SFM's data comes only from the binary; reports are for checking.
- The disagreement rule and carve-outs above.
- The two outputs: a summary for him, a detailed report for Claude to diagnose.
- Repeated runs with run-to-run comparison.
- It lives in seismo-relay, and the comparison is library code.
- Series 3 only. Nothing on prod or in Terra-View changes.
**Claude's calls (correct if wrong):**
- The XML is the single reference.
- **Placement:**
- The XML report parser belongs in the codec library, a sibling of
`minimateplus/bw_ascii_report.py`.
- The comparison (one decoded `Event` + one parsed report → verdicts per
field) is pure and belongs in the codec library too.
- The batch runner is a lab tool (`scratch/`), per ADR 0003.
- The carve-out list lives in the repo next to the comparison, as code or
data the comparison reads, with each entry's evidence written beside it.
- **Grouping attributes for the detailed report:**
- device model (from `Version`), serial
- event type, event year
- sample rate, geophone range, mic units/weighting, interval size
- whether the setup is named "Standard Recording Setup"
- which decoder path produced the samples, where the decoder exposes it
- `scratch/verify_bw_fields_against_xml.py` (committed `f46afaf`) is the
starting point. It already handles the notes/job-number layout and the
rounding rule. The checker replaces it.
**Left to the builder:**
- module, function and file names; the output file formats
- how runs are stored and compared
- parallelism and any caching of decode or parse results
- the CLI shape, as long as the partial-run filters and single-event re-run
exist
## What success looks like
- **One command** produces the summary and the detailed report for all 70,042
events within the time budget.
- **The first run reproduces what is known**, which is how we tell the
checker is honest:
- sample rate, record time, pre-trigger and notes match everywhere
- `T438HGTZ.B30W` matches. Its Tran, Vert and MicL end 3 samples before
Long, and Blastware's own table does the same: its last rows carry only
the Long cell. An earlier harness that compared one channel's length with
the table's row count called this a decoder truncation; it was not.
- samples and histogram intervals match on the 2025–26 events, as
`verify_against_ascii.py` showed, **except the events on the 1.250 in/s
range**, which are 8× high (5 of them in 2025–26, 35 in all)
- event type mismatches on every histogram, because no filename is given
(#41)
- job number and the calculated values (ZC frequency, acceleration,
displacement, time of peak, sensor check, battery, calibration, trigger
levels, range, units, monitor log) show up as SFM blank
- the three `#53` files fail loudly as waveform time mismatches, 4 s off.
The decoder picks an earlier, false footer and records no
`decode_problems`. The `#53` description in
`docs/instantel_protocol_reference.md`, which says they decode as
histograms, is out of date.
- Every non-match group in the detailed report carries example files and a
re-run command.
- Tests cover the XML parser on real fixture reports with literal expected
values, every comparison rule (rounding, `&gt;100`, `N/A`, `OORANGE`,
units), carve-out accounting, and a guard that the SFM side never sees the
reference.
@@ -1,403 +0,0 @@
# Phase 5: changing a unit's settings by serial (design)
**Date:** 2026-11-03. **Status:** approved by Brian 2026-11-03; built 2026-11-03
(plan `docs/superpowers/plans/2026-11-03-sfm-phase5-settings.md`); **benched 2026-11-04** on both
series (results at the end). Phase 5 of
`docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` (row 10, "change
recording settings"; build phase 5, "setup push: one field first, then several").
**Branch:** `feat/series4-sfm-parity`.
## Intent (Brian, 2026-11-03)
Change **any** of a unit's settings from SFM, and make it as easy and reliable as
possible. The goal is to fix what makes Blastware finicky. Three real cases:
- **One wrong number on a deployed unit.** UM6047 was out monitoring with its
geophone trigger at 0.03 instead of 0.300. Brian remoted into the THOR PC,
stopped it (it called in), changed the setup, made sure it was *sent*, then
restarted monitoring.
- **A typo in the notes.**
- **A backup unit.** The unit set up at the office fails in the field, so a backup
from the truck goes in with blank or stale notes and settings. There is no
computer in the field, so the office re-does the whole setup remotely, by hand,
while the person in the field stands by to press Start or power-cycle if the
link breaks.
What is wrong with THOR, as Brian and his dad experience it:
- The same screen edits a setup on disk and views a unit's setup.
- Setups get saved under random number strings.
- Editing a setup does not change the unit; you verify separately that it was sent.
Saved setups as templates would be acceptable. Not knowing whether you are
changing the unit or a file is not.
## Goals, non-goals, anti-goals
**Goals**
- Edit the unit's **live** settings, both series.
- Show exactly what will change, **old → new**, before anything is sent.
- After sending, **re-read the unit** and show what it now holds.
- Make every refusal say why, in plain words.
**Non-goals (this phase)**
- Templates, saved setups, copying from another unit.
- Restarting monitoring. **Brian presses Start**, as today; SFM never restarts on
its own.
- Setting the unit's clock. That is a later call-home receiver rule.
- **Writing the Micromate scheduler.** Next project, agreed 2026-11-03:
"record during work hours" as a plain, **configurable** setting on the unit's
page, both series, no schedule library and no setup files. On the Micromate,
it relies on the firmware's setup-less scheduler start (found in the firmware,
never sent; one bench session). On the MiniMate, its own timer setting
(undecoded). Brian's dad despises THOR's scheduler; Brian is willing to retire
it in SFM.
- Fields not yet decoded. "Any and all" grows as decoding grows.
**Anti-goals: things that would make it a failure even if it "works"**
- Any doubt about whether the unit changed.
- A screen where a file and a unit look alike, or a name SFM made up.
- Writing a byte SFM did not just read. Every byte SFM does not deliberately change
goes back exactly as read. The one exception is a byte that Blastware's (or
THOR's) own writes always set to a fixed value. Each such byte is named in the
codec with its evidence (so far: Series 3 `[26:28]` → `00 00`; my call, below).
- Sending to a monitoring unit.
- A retry. A write is sent once; what happened is read back.
## Measured basis
**1. Series 4 (Micromate): the `0x1A` setup content map.** Measured from 47
keypad snapshots on UM20147 and checksum-verified. `micromate/setup_block.py`
(`decode_setup`) reads it, with 69 tests on 15 fixtures.
| content | field |
|---|---|
| `[5]` | record mode |
| `[6:8]` | sample rate |
| `[8:10]` | histogram interval |
| `[12:16]` | pre-trigger, f32, negative |
| `[17]` | stop mode |
| `[18:22]` | record time, f32 |
| `[23]` | auto-stop |
| `[25]` | active sensors |
| `[29]` | trigger sources |
| `[30:34]` | distance |
| `[34:38]` | charge |
| `[39]` | report flags |
| `[40:42]` | job number |
| `[42:86]` | setup name |
| `[122+64n]` / `[144+64n]` | notes (label / value) |
| from `[1708]` | 48-byte channel blocks: sensor code `+4:8`, trigger `+30` (geo in/s, mic psi) |
The CRC-16/AUG-CCITT over `[0:2088]` is stored at `[2090:2092]`; THOR's write
omits it and the unit recomputes it.
- **The push sequence (from THOR's captures)** is `0xDA` (name) → `0x68`/`0x73`
(`0x08` preferences) → `0x82`/`0x83` (`0x2E` trigger) → `0x71`/`0x72` (`0x1A`
setup). `micromate.writes.plan_setup_push` reproduces THOR's frames (phase 2).
- **Not yet mapped on Series 4:** alarm level, geophone range, GPS, aux I/O, SLM
options.
**2. Series 3 (MiniMate) uses the same layout. Measured 2026-11-03.** The
compliance image as Blastware writes it is logical (unescaped), 2,092 bytes, with
`N = 2090` at `[0:2]` and the channel block "Tran" at `[1708]`.
`micromate.setup_block.decode_setup` reads it correctly:
- **BE9441's 10-26 write** (`tests/fixtures/minimate-bench-10-26-26-histogram`,
two whole sends): name, mode, 4096 sps, interval, record time 20 s, trigger
0.04 in/s, mic linear, job number and the notes all decode. Only the CRC fails
(Series 3's tail goes out stale).
- **BE11529's nine 2026-04-20 Blastware writes** (`bridges/captures/4-20-26/`,
every one with a whole image) each changed exactly the expected bytes:
| Blastware changed | bytes that moved |
|---|---|
| histogram interval (×4) | `[8:10]` |
| recording mode (×3) | `[5]` |
| geophone range | `1737` / `1785` / `1833`, the range byte at each geophone channel label `+29` |
- **The live `SUB 1A` read starts the same block.** Measured on the first data
frame of each of the four recorded reads (`_settings_replies` in
`tests/test_s3_compliance_anchor_fields.py`): unescaped, each carries `N = 2090`
12 bytes before the old "anchor", and content `[5]` reads 1 / 4 / 3 / 3. That
anchor (`be 80 00 00 00 00`) is content `[12:18]`, pre-trigger −0.25 plus stop
mode Fixed. So Series 3 can be read by content offset rather than by anchor
search, which survives an Auto-stop unit (the open question of 2026-10-17).
- **A whole `1A` read assembles to exactly the 2,090 content bytes** (measured
2026-11-03 on BE9441's 10-26 recording, 12 reads). Unescape each data frame and
take `data[11:]`. Every frame but the last then starts with one `00` byte that is
not content; drop it. This holds for Blastware's read (four 512-byte frames plus
42) and SFM's (two 1024-byte frames plus 42).
- **The round trip is exact.** Blastware re-read the block after each of its two
writes, and each re-read equals the image it had just written, all 2,090 bytes.
- **While monitoring**, the read returns `0e 'BE9441' …` (the device-info block),
as the 10-29 finding says. The unit was monitoring for 5 of the 12 reads.
- **Bytes `[26:28]`: Blastware always writes `00 00`** (all 11 writes), though the
unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19).
The unit sets them again by itself. Meaning unknown.
- **The two bytes after the block are Blastware's own.** Blastware sends a per-unit
constant: `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's.
It is not the block's CRC-16/AUG, and no reply in BE9441's three-hour session
contains it. SFM's `write_image` sends `00 00` there. Since a read never returns
those bytes, the read-back cannot show what the unit did with them.
- **The mode byte is shared, but its codes are not.** Series 3: `00` Single Shot,
`01` Continuous, `03` Histogram, `04` Histogram + Continuous. Series 4: `01`
Waveform, `02` Manual, `03` Histogram, `04` Combo.
- **Rules from the checker's file-side work** (seismo-relay-b6, 2026-11-03; it
measured the same content offsets on 70,042 event files and found nothing that
contradicts one shared map):
- A bitmask byte is patched **bit by bit, never rebuilt**. The trigger-sources
byte `[29]` showed an unidentified `0x80` bit on one unit.
- On Series 3, stop mode (`0` Fixed) and mic type (`2` linear) are proven for
one value each. They are not offered for writing.
- An event file's `[12:16]` is that event's captured pre-trigger, not the
setting. SFM writes only from a live read, so this matters only to anyone
tempted to build a write from a file.
- **Series-3-only fields** (measured on Series 3, not Series 4): the geophone range
byte at channel `+29`; the alarm level at channel `+38` (checker-measured on
event files; live raw `+42`).
**3. Series 3 write frames are measured (#46).** Writes use uniform escaping with
a length field. The compliance image goes in 512-byte addressed chunks. `0x68` is
written as read plus `02 00`, `0x82` plus `00 00`. The sequence is
`68→73 | 71×n→72 | 82→83 | 69→74→72`. `push_config_raw` refuses any block that
is not whole. `tests/test_minimate_write_frames.py` rebuilds Blastware's frames
byte for byte.
**4. Monitoring.**
- **Series 3:** while monitoring, the unit answers `1A` (and `0x2C`) with its
device-info block (measured 10-29 and 11-03).
- **Series 4:** it refuses call-home setup while monitoring ("Feature disabled
while monitoring", measured 11-03).
- **A stop with call-home on makes the unit call in** (measured 10-25, 10-29,
11-03).
**5. Series 4 specifics.**
- `0x1A` reads the keypad's edit buffer live: unsaved keypad edits show in the
read, and a push would commit them.
- Loading a `.MMB` replaces the active config byte for byte. The push writes
under the active setup's name (`0xDA`).
## The flow
1. **Read.** `GET /device/settings?serial=…` (it exists) returns the unit's
settings. The page shows them on the Config tab under **"On the unit BE9441 —
read 14:03"**, never anything that looks like a file.
2. **Edit and preview.** The operator changes fields, then **Preview**: a dry run.
SFM re-reads the unit's blocks on the same line, builds the new blocks, and
returns one row per field: **old → new**, plus any warnings. Nothing is sent.
3. **Send.** The same request, live, is an audited change:
- identity check, audit row, one send, never retried, read back;
- **refused with "stop monitoring first"** if the unit is monitoring, noting
that the stop makes it call in when call-home is on;
- **refused** if the unit's settings changed since the preview. The preview
carries a revision (a hash of the blocks read), and the live call must
match it.
4. **Verify.** Re-read the blocks. Every changed field must read its new value.
Every other decoded field, and every byte SFM did not deliberately change, must
read as before. The page shows **"the unit now holds"**: field, old, new, now.
Known unit-maintained bytes (the Series-4 CRC) are compared as the unit's own
checksum (`crc_ok`), not byte for byte.
5. **Start** stays the operator's button.
## Fields in the first version (Brian approved the list)
| field | Series 3 | Series 4 |
|---|---|---|
| geophone trigger level | yes (channel `+30`) | yes (channel `+30`) |
| alarm level | yes (channel `+38`; measure live) | not mapped, so not offered |
| notes: the four note slots, by the unit's own labels | yes (`Project:`, `Client:`, `User Name:`, `Seis. Loc:` on BE9441) | yes (`Location`, `Client`, `Company`, `General Notes`) |
| recording mode | yes (`[5]`; values as measured on Series 3) | yes (`[5]`; Series-4 codes) |
| sample rate | yes | yes |
| record time | yes | yes |
| histogram interval | yes | yes |
| geophone range | yes (channel `+29`) | not mapped, so not offered |
| job number (+ shown on report) | yes | yes |
A field is offered only where it is measured for that series. Values are refused
unless they are among the measured choices: sample rates 1024/2048/4096,
intervals 2/5/15/60/300/900 s, and each series' measured mode codes.
- **Numbers: the units' own limits (Brian, 2026-11-03: "I want to use the actual
unit limits, not just what we have done in the past").** From Instantel's
operator manuals in `~/seismo-relay/manuals/`:
- **Geophone trigger:** 0.005–10 in/s in steps of 0.001 (MiniMate Plus manual
716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual
721U0201 Rev 06, *Geophone Trigger Level*). It is also capped at the range's
full scale (10 / 1.25 in/s). When range and trigger change in one request,
check the trigger against the **new** range.
- **Record time:**
- Micromate: 1–90 s (*Record Time*).
- MiniMate: from 1 s to the manual's §4.4 *Maximum Record Times* for a
1 MB unit, four channels, at the chosen sample rate: 104 s at 1024 sps,
52 s at 2048, 26 s at 4096. In Histogram Combo, 13 s (§3.8.9). The units
measured report about 960 KB in total memory (BE11529: 983,026 bytes), the
1 MB model.
- **Job number:** 1–9999 (both manuals).
- **The read-back is the safety net.** A unit that does not take a value (for
instance, cuts a record time to what its memory allows) shows as not taken,
with what it actually holds.
- Values seen across 75,958 Blastware reports (2016–2026) sit well inside these
limits: trigger 0.005–0.500 in/s, record time 1–10 s, job number 1.
- **Units:** refuse a level write unless the channel's unit string reads the
measured one (`in.` for a geophone). A unit set to Metric is unmeasured.
- **Notes:** edited by slot, under the label the unit itself shows (labels can be
renamed and are not identifiers). The value is at most its field width less
one byte, printable ASCII.
- Not in v1: Series 3's fifth slot, `Extended Notes` (value `\n` on BE9441).
Blastware's extended notes are unmeasured and may live elsewhere.
- Not in v1: Series 4's 16-byte field at content `[1064]` (`Loc 1` on
UM12947), undecoded.
## Architecture
- **One setup-block codec for both series.** Keep `micromate/setup_block.py` as
the field map and add `encode_setup(content, changes) -> content`: field patches
only, every other byte as given. It stays a pure codec library: no I/O, no
`sfm` imports, no import cycle with `minimateplus`. Series-specific fields (the
Series-3 range and alarm) are marked by series.
- **Series 3 read.** Assemble the `1A` read into the logical 2,090-byte block:
unescape, strip the 12-byte reply prefix and the inter-frame headers
(`read_compliance_config`). Decode it by content offset.
- **Series 3 write.** The patched logical block plus the tail becomes the
compliance image for `push_config_raw`. Event index (`0x08`), trigger (`0x2E`)
and waveform data (`0x09`) are echoed as read, in Blastware's sequence.
- On `0x09`, Blastware echoed the unit's bytes on all nine April writes
(`[200:202]` = `8c 76` read and written). Only BE9441's 10-26 writes changed
them (`17 17` read, `78 76` written, and read back so). The meaning is
unknown, so SFM echoes.
- **The raw-offset `_encode_compliance_config` is retired.**
- **The legacy write (`/device/config`, `/device/config/project`) is retired (my
call).** It retries a whole write on a TCP error, is not audited, does no
read-back, does not refuse a monitoring unit, and needs no serial: every
anti-goal at once. Its only user is the webapp's by-host Config form, and
Terra-View does not call it. Its routes answer with a pointer to the by-serial
change, and the by-host form becomes read-only.
- **Series 4 write.** `plan_setup_push(prefs, trigger, patched_setup, name)`.
- **No setup files in the operator's view (Brian, 2026-11-03).** "We treat the
Micromate setups just like Minimate setups … the unit just has its settings,
and we change it based on the job. We don't send setups to the unit." A
backup unit is usually on whatever setup its previous job left. So SFM
rewrites the setup the unit is running, in place, under its own name. It
never asks for a file or a name, and never creates one. The name may show as
a read-only detail, since the unit's screen shows it.
- **The scheduler can undo a change (Brian, 2026-11-03, with THOR's Manage
Schedules screen).** Work-hours Micromates run a THOR schedule, e.g. Start
Monitoring 07:00 with setup `Mele-PWSA-Carroll -Loc 4`, stop 18:30, repeat
daily. THOR sends the schedule with its setup, and each scheduled start loads
the setup it names. So the preview and the send read `schedule.dat` (format
decoded, reference *The schedule record format*), read-only. A start action
naming a setup other than the one being changed blocks the send: "this unit's
schedule loads <name> at 07:00, which would replace this change." When the
schedule names the active setup (the usual case after a scheduled start), the
change survives, and the preview says when the next scheduled start is.
SFM never writes the schedule in this phase.
- The name comes from the `0x41` read, unstripped.
- Refuse `factory.MMB` and any target that is not the active setup (spec). The
refusal says it plainly: "this unit is running its factory setup; load any
other setup on its keypad, then try again." Brian says the team does not use
the factory setup, so this should be rare.
- `ENABLEABLE_WRITES` gains `0xDA 0x68 0x73 0x82 0x83 0x71 0x72`.
- The keypad edit buffer: warn in the preview that a unit with someone in its
menu would have those edits committed. The check the spec names, `0x1A`
against the active `.MMB` via `0x94`/`0x48`, is a bench question first.
- **The change path.** It keeps run_change's guarantees: identity, audit, one
send, read back, `ChangeUnconfirmed` with `sent`/`audit_id`. The "state" is a
set of fields, so either `run_change` takes a verify function or a sibling core
shares its parts. The builder decides; the guarantees do not change. The audit
row keeps the per-field changes, both blocks (hex) and the verdict.
- **Routes.** `POST /device/settings/change?serial=…` (serial required) with body
`{changes: {field: value}, revision}` and `dry_run`, `caller`. The response is
per-field `old` / `new` / `now`, through `_change_response`. A dry run needs no
revision and returns one. **A live call without the revision of a preview is
refused** (my call): nothing reaches a unit unless someone saw old → new.
- **Page.** The Config tab by serial becomes the unit's edit form: Preview → Send
(confirm) → "the unit now holds". New logic goes in
`sfm/static/device_routing.js` with Node tests, and glue in
`sfm/static/sfm_webapp.js` (no inline JS).
## Verification
- **Series 3, byte for byte.** For each of the 11 Blastware compliance writes,
apply the new encoder to the read before it (or the previous image), with the
fields Blastware changed. It must reproduce Blastware's content `[0:2090]`. The
two trailing bytes are compared separately, since they are Blastware's constant.
Ten writes change one field. BE9441's 16:26 write changes five things: mode,
sample rate 2048 → 4096, interval, the mic in the sensors byte `[25]`, and
`[26:28]`. That one is tested with all of them, through the codec, though v1's
page does not offer the sensors byte.
The frames rebuild through `push_config_raw`'s path (the #46 tests).
- **Series 3, read side.** The assembly rule above, pinned as a test on the 12
reads of BE9441's 10-26 recording. Each read-back equals the write before it.
- **Series 4.** THOR's setup-push captures still reproduce, with no field changed.
Any capture where THOR changed a field becomes a byte-for-byte test.
- **Bench, with Brian's go per send, per series:**
1. A dry run of a trigger change, then send, read back, check the unit's menu,
and change it back.
2. A notes change.
3. A several-field "backup unit" change.
4. A dry run while monitoring, expecting the refusal.
## Bench 2026-11-04 (results)
Brian at BE9441 and UM20147, each on its own modem; every send with his go.
Notes: `~/bench-logs/2026-11-04-sfm-settings/`.
- **Both series change correctly.** Each change was acknowledged, read back as
sent, and confirmed on the unit's own screen; both units ended byte for byte as
found.
- BE9441: trigger each way, a note, several fields at once, the alarm, a full
restore.
- UM20147: trigger, several fields (two notes, job number and its flag, record
time), a full restore. The unit's recomputed CRC equalled SFM's.
- **Fixed at the bench (`9992b25`):** the first live MiniMate read came back one
byte long. An escaped checksum byte leaves its `0x10` behind (about 1 frame in
85; the recordings never had it). The read now takes exactly the lengths it
asked for, and so does the waveform read (`c790e20`).
- **🔑 The keypad menu wins.** A MiniMate change sent while its setup menu is
open is acknowledged and read back, then lost when the operator presses Cancel
or Save: the menu writes its copy of the whole block back. SFM cannot see this
happen; the MiniMate preview now warns. Rule for the field-plus-office routine:
nobody in the unit's menus while the office sends.
- **The MiniMate alarm write is measured**, so it is now writable (`55c7b7b`).
- **Refused while recording, both series, nothing sent.** A recording MiniMate
sometimes leaves a preview at "no answer" rather than the refusal.
- **The Micromate scheduler switch is in no block SFM reads.** UM20147 carries a
leftover THOR schedule (Fay setup, 07:00 daily) with the switch Off; SFM blocks
it, a false alarm here. The bench used a scratch-only override.
- Next: a THOR bridge recording to find the switch (parked for work hours).
- Meanwhile, worth considering: let the operator confirm "scheduler off" in the
preview.
## Calls I made (Claude), for Brian to check
- **Series 3 `[26:28]` goes out as `00 00`, as Blastware writes it**, rather than
the `01 7f` the unit may read. Measured beats inferred: Blastware's value is on
11 accepted writes, and writing back `01 7f` has never been tried.
- **The two bytes after the Series 3 block stay `00 00`**, as `write_image` sends
them (a unit accepted that in the April 2026 test). Blastware's per-unit
constant cannot be derived from anything SFM reads. The first bench write checks
that the unit takes the block, and its menu shows the change.
- **The `0x09` block is echoed as read**, as Blastware did on all nine April writes.
- **Level writes are refused unless the channel's unit string is the measured
`in.` / `in`** (a unit set to Metric is unmeasured).
- **Notes are edited by slot under the unit's own labels**, four slots on each
series. Series 3 extended notes and Series 4's separate location field wait.
- **The legacy by-host write is retired**; the by-host form becomes read-only.
- **A live send needs a preview's revision.**
- **Preview re-reads the unit** rather than trusting the page's copy, and Send
refuses if the unit changed since the preview.
- **The edit form lives on the Config tab, by serial**, replacing the legacy
read-modify-write form for units reached by serial.
## Left to the builder
- The module layout for the shared codec, within the no-cycle, pure-codec rule.
- `run_change` generalised versus a sibling core.
- The exact revision hash.
- Page layout details.
@@ -1,333 +0,0 @@
# Monitor logs (.MLG) and each unit's monitoring timeline — design
**Date:** 2026-11-09 · **Branch:** `feat/mlg-import` (worktree `~/seismo-relay-mlg`) ·
**Status:** design, for review
## Why this exists
Every Series-3 unit sends a Blastware monitor log, an `.MLG` file, at every call-in, whatever mode
it is recording in. It lists each time the unit started monitoring, each event, and each time it
stopped and why. Event files cannot replace it: a unit in continuous (waveform) mode sends an event
file only when something triggers, so a quiet day leaves no file at all.
Brian named two uses (2026-11-09):
1. **Shot reports.** Every event from every unit on a site goes in the report. A unit that did not
trigger (often the farthest one) is listed as "did not trigger", with its printed `.MLG`
attached as proof it was monitoring at the time of the blast. Example: BE6907 and BE12844
monitored the same job, June to November 2026, both in continuous mode. BE6907 is much farther
away and recorded 10 events to BE12844's 55.
2. **Outage history.** It is good to know when a unit was not recording, for how long, and why. A
unit on solar and battery can die for a weekend and nobody would notice. Most units keep
recording when they cannot call in; only losing the power and then the internal battery stops
them. So this is history seen once the unit calls in again, not a live alarm.
The `.MLG` is also what the watcher's heartbeat sniffs today to show that a unit is still calling
in. SFM holding the files would later let it answer that itself.
## Goals
1. Read a Blastware `.MLG` into its records, with every record's checksum verified.
2. Accept forwarded `.MLG`s through a new import route, storing each record once.
3. Keep each unit's monitoring timeline, derived from its records: when it was recording, how each
session ended, the events inside, and the call-ins. It must answer two questions:
- was unit X monitoring at time T, and with what trigger level?
- when was it not monitoring, for how long, and why?
4. Serve the records and the timeline through `/db/*`, for Terra-View to use later.
5. Bulk-import a directory of `.MLG`s (DL2 holds about 86,000), and cross-check the records against
the event files' footers.
## Non-goals
- **The watcher forwarding `.MLG`s.** That is a change in `../series3-watcher`, Brian's call, and a
separate piece. Until it lands, `.MLG`s reach SFM only through the import route and the bulk tool.
- **Anything in Terra-View:** the timeline view, the shot report, taking "last call-in" from SFM
instead of the heartbeat. Later pieces.
- **Live "missed its call-in" alerts.** A dead unit sends nothing; this timeline shows the gap
once it is back.
- **Series 4.** Thor writes no `.MLG`.
- **Editing the event decoders** (`event_file_io.py`, `decode_check.py`, `histogram_codec.py`,
`waveform_codec.py`). Another session owns them; this project imports from them only.
## Anti-goals (would make it a failure even if it works)
- **Claiming monitoring the data does not show.** A session still open at the last call-in is
"running at the last call-in", never "running now". Where a session's end is not recorded, the
timeline says so and gives the window it lies in.
- **Dropping a damaged file or record silently.** A record that fails its checksum is reported,
never half-read into the timeline.
- **Taking the serial from the file name when the file carries it.** Names are `<serial><counter>`
with nothing between, so `BE11010304` cannot be split by reading it.
- **Mixing clocks.** Record times are the unit's own local clock. File times are the PC's. They are
stored and labelled separately.
## What was measured
Grades: **measured** means checked on the files named; **inferred** means a reading of them that
has not been tested.
**Files examined:** 1,273 `.MLG`s from DL2's `C:\Blastware 10\Event\autocall home` (BE6907 369 and
BE12844 197, from 2026; BE8081 707, 2018–19), in `~/dl2-archive/mlg/`. Also the 9 bench files in
`example-events/`. Analysis scripts used for this section are in the session scratchpad and are
not part of the build.
### The file format (measured on all 1,282 files)
- **Layout:** an 18-byte prefix `10 00 01 80 00 00 "Instantel\0" 07 2c`, then whole 292-byte
records. The size is always `18 + 292·n`.
- **Every record** is `[length uint16 LE = 0x0122 (290)][id 2 bytes] … [CRC 2 bytes]`. Id `0e a0` is
the header record (one, first, carrying the serial). Id `0e 80` is a log record.
- **Checksum:** CRC-16/AUG-CCITT (poly 0x1021, init 0x1D0F, no reflection) over the record's bytes
`[0:288]`, stored little-endian at `[290:292]`. Bytes `[288:290]` are `00 00` and not covered.
This is the rule the Micromate setup blocks use (`micromate.setup_block`). It matches **3,329 of
3,329** records, with no failures.
- The reference (D.4.2) put a CRC at the *start* of each record. That was the previous record's
tail, which is also why every file had 2 unexplained bytes at its end.
- **A log record** (offsets from its length field):
| offset | field |
|---|---|
| `[4:12]` | start: day, month, year **LE**, 0, hour, min, sec |
| `[12:20]` | stop, same format; all zeros = no stop |
| `[20:22]` | monitor-log flag word, uint16 LE: the same word as the event footer's (D.6.14) |
| `[22:24]` | trigger source, uint16 LE: `0x0001`–`0x0008` a channel, `0x0400` a histogram |
| `[24:34]` | serial, null-padded ASCII |
| `[34:…]` | text, null-padded (below) |
- **Text:**
- a "monitoring started" record: `Trigger Level : Geo: 0.0500 in/s Mic: 125.0 dB(L)`, or
`Trigger Level : Histogram`
- an event record: `08`, then the event time in 8 bytes (LE year), then
`Geo: 0.0500 in/s Mic: 125.0 dB(L)`
- a closed session: `Geo: 0.0500 in/s Mic: 125.0 dB(L)`
- **Empty files:** some files are the 18-byte prefix alone, with no records and so no serial inside.
### How Blastware writes them (measured on the 3 DL2 units)
- **One file per call-in**, named `<serial><counter>.MLG`, the counter going up by one each time.
- **No record appears in two files.** Each holds what happened since the previous call-in.
- **A file is written 1–2 minutes after the unit stops for its call-in** ("Modem Exit"). The unit's
clock and DL2's agree to within those 2 minutes.
- ⚠ Dates of files that came through a Windows zip read an hour early from March to October.
Windows converts with the offset in force at zip time, not the one at the file's date. A
robocopy copy keeps the true time.
- **BE6907 writes two empty files 2–3 minutes after nearly every real one** (230 of its 369).
BE12844 never does; BE8081 did once in 707 (`BE80811.MLG`, 2018-02-19; corrected 2026-11-13
by the final review). Inferred: the unit calls back in and has nothing new.
- **Some files hold more than one Modem Exit:** 38 files (BE8081 33, BE6907 3, BE12844 2). A
file is written just after its *last* Modem Exit. The earlier ones are calls that left no file.
Example: `BE8081321` holds Modem Exits on 2019-04-12 18:33, 04-13 07:00 and 04-15 17:15.
- Inferred: the call failed, or the PC did not take it.
- Either way, this is the "missed call-in" history Brian asked about.
- **The unit's clock steps back an hour at the first call-in after daylight saving ends.** On
2026-11-01 BE12844 ran `06:00:13 → 18:45:00` (unit still on EDT). It called in at 17:46 EST,
and its next session is `17:47:25 → 18:45:00`. BE6907 shows the same. So local times on that day
overlap. Inferred: Blastware sets the unit's clock at the call-in, and in spring the clock
steps forward the same way.
- **Blastware writes the text, not the unit.** The two bench copies of the same records
(`ach-vs-manual/BE11529.MLG`, `BE115292.MLG`) differ only in `Trigger Level: Histogram` vs
`Trigger Level : Histogram`. A record's identity must not include its text or its checksum.
- **Cable or direct downloads are cumulative.** The bench `4-3-26-multi/BE11529.MLG` repeats the
4-1 records. Only the call-in files hold "only what is new".
### How a session appears (measured on the 3 DL2 units)
- **A session with no events** is one closed record: start, stop and why it stopped. BE12844's day:
`06:00:13 → 18:45:00` "Modem Exit" (its call-in), then `18:47 → 20:00` "Timer Stop" (a
work-hours timer).
- **A session with events** is an open "monitoring started" record (flag word `ffff`, no stop),
then one record per event (`0x0001` + the channel). The unit calls in minutes after each event,
and monitoring resumes as a *new* session minutes later. Example, BE12844 on 9-8:
- `06:00:13` started, then an event `13:38:22 → 13:38:25` (Tran)
- a file written about a minute later
- next file: `13:41:16 → 18:45:00` "Modem Exit"
The first session's end is not written anywhere. It lies between the last event's stop and the
next session's start (inferred: the call-in after the event ended it).
- **A histogram session** is a "monitoring started" record at T, then a histogram record from T+1 s
to the stop, carrying the stop reason (`0x0021` = Event Recorded + Modem Exit, source `0x0400`).
- **A histogram + waveform session** also has waveform event records whose start falls inside the
histogram record's span (BE8081, 5 in 2018). Example: histogram `15:15:32 → 15:15:49`, with a
Vert event `15:15:47 → 15:15:49`. Its trigger-level text says only "Histogram". The geophone
level appears only on its event records.
### Cross-check against the event files (measured)
Each "Event Recorded" record was matched to DL2's event files by **stop time + flag word + trigger
source**:
- **BE8081:** 785 / 785 records match an event file, and all 785 of its DL2 event files in that
period have a record. 714 histogram footers start exactly at the session's "monitoring started"
record; the other 71 start where the record does.
- **BE6907 / BE12844:** 25 / 25 event files have a record. The 42 records with no file all stop
after 2026-08-25, where the DL2 copy ends.
- On 2026-08-27 both units triggered at 13:00:42 / 13:00:43, the same blast.
## Design
### 1. The reader (codec library: pure, no I/O beyond the file)
`read_mlg(path)` replaces the stub in `minimateplus/blastware_file.py` and returns a new model
(`MlgFile`, `MlgRecord` in `models.py`). It does not reuse `MonitorLogEntry`, which is the live
0x0A shape. Per record:
- start, stop (None when open), flag word, trigger source
- Blastware's words, from `event_file_io.monitor_log_description()` (imported, not copied)
- the text, plus the trigger level and the event time parsed from it
- whether the checksum passed
Per file: the serial (from the header record; None for an empty file), the records, whether the
file is whole. A file whose size is not `18 + 292·n`, or with a bad prefix, raises. A record that
fails its checksum is returned flagged; the caller decides.
### 2. `write_mlg()` (last, small)
Fix it to write what Blastware writes: little-endian times, the length-led framing and the CRC.
Test: rebuild bench and DL2 files byte for byte from what the reader returns. If the header
record's unread bytes stop that, say so and leave the writer as it is.
### 3. Storage (`sfm/database.py`)
- **The original file is kept, byte for byte,** in the waveform store beside the unit's event
files. Files are tiny (18 bytes to a few KB). It is the shot-report proof, and Blastware can
open and print it. Rows alone cannot rebuild it, because Blastware's text varies.
- **`mlg_files`:** one row per file received:
- serial, file name, size, SHA-256, record count, an empty flag
- received time, and the file's modified time (UTC, when the sender gives it)
- whether it is a call-in file (default yes; a cable download is not)
The same name with the same bytes is a re-send and is skipped. Empty files all share one
hash, so the name keeps them apart. Some names have no counter (`BE8081.MLG` was DL2's first),
so name alone is not enough. This table is the call-in history, and the only trace of an empty
file.
- **`mlg_records`:** one row per log record: serial, start, stop, flag word, trigger source, text,
and the file it first came in. Stored once:
- unique on `(serial, start, stop, flag word, trigger source)`
- ⚠ an open record's stop is NULL, and SQLite treats NULLs as distinct in a UNIQUE constraint.
The key must handle that, for example with an index on `COALESCE(stop, '')`.
- **The existing `monitor_log` table is left alone.** It holds live 0x0A rows from
`bridges/ach_server.py`, which is not in production. A future SFM call-in server would write
`.MLG`-shaped records into `mlg_records` instead.
### 4. The timeline (computed when asked, not stored)
From a unit's records in time order:
- **A closed record** with no event bit is a session `[start, stop]`, ended for its reason.
- **A histogram record** is a session from its "monitoring started" record (or its own start, when
there is none) to its stop, ended for its reason.
- **A "monitoring started" record followed by events** is a session from that start. Its end is
"between the last event's stop and the next session's start".
- **A "monitoring started" record with nothing after it yet** is "running at the last call-in".
Gaps between sessions take the reason the previous session ended with:
| previous session ended with | the gap means |
|---|---|
| Modem Exit | a call-in |
| Timer Stop | scheduled off |
| Battery Low Exit | lost power |
| Keyboard Exit / Remote Exit | stopped by a person |
| Memory Full Exit | memory full |
| none known | unknown |
- **Waveform events inside a histogram session** belong to that session. They are not sessions
of their own.
- **Trigger level is reported as logged:** the session's text, plus any geophone level its event
records carry. It is never borrowed from a neighbouring session. A histogram session with no
events says "Histogram", geophone level not logged.
- **Clock steps:** a session that starts before the previous one stopped is a clock step, not an
overlap. The timeline shows it as such, with no negative gap. Times are the unit's local clock,
as SFM's event times are; `at`, `from_dt` and `to_dt` are in that clock. If `at` falls in a
repeated hour and matches two sessions, `monitoring_at` returns both and says so. The spring
step forward will show as a gap an hour too long on that one day; that is accepted.
**Call-ins** are listed by the call each file came from:
- **Delivered:** a call-in file's last Modem Exit (unit clock), paired with the file (PC clock).
- **No file:** the earlier Modem Exits in the same file. Calls that left no file.
- **Nothing new:** an empty file, at its file time.
Cable-download files are not call-ins.
### 5. Routes (`sfm/server.py`)
- `POST /db/import/mlg_file`: one or more files, an optional serial hint, each file's modified
time when the sender has it, and `call_in` (default true).
- Mirrors `/db/import/blastware_file`: each file gets its own status, and good files are stored
even when another in the same request is not.
- Per file it returns the serial, records inserted and skipped, and whether it was empty.
- A file with any failed checksum, or that is not whole, stores nothing of itself. Its status
names the record.
- `GET /db/mlg_files/{id}`: the original file, for printing or opening in Blastware.
- `GET /db/units/{serial}/timeline?from_dt=&to_dt=`: sessions (start, end or end window, how it
ended, its events, its trigger level), gaps with their meaning, and call-ins.
- `GET /db/units/{serial}/monitoring_at?at=`: `monitoring` / `not_monitoring` / `unknown`, with the
session and records that say so, and the trigger level. This is the shot report's question.
- `GET /db/mlg_records?serial=&from_dt=&to_dt=`: the raw records.
### 6. Serial of an empty file
An empty file holds no serial. Take, in order:
1. the request's serial hint
2. the longest serial SFM already knows (units, events, `.MLG` headers) that the name starts with
3. otherwise store the file with no serial and report it as unresolved
### 7. Tools
- **`scripts/import_mlg_dir.py <dir>`:** imports a directory tree of `.MLG`s straight into the DB,
with a dry run that prints the counts. Same pattern as the backfill scripts. For DL2's ~86,000.
- Every file it reads is a call-in file (it is pointed at the ACH folder's copy).
- It records file times as found, but they matter only for empty files. A zipped copy's times
are an hour early from March to October.
- The full DL2 import should come from a robocopy copy, which keeps true times.
- **`scratch/check_mlg_vs_events.py <mlg dir> <event dir>`:** the cross-check above, in both
directions, for the whole archive.
### 8. Documentation
- Rewrite the reference's D.4 (`docs/instantel_protocol_reference.md`) with the measured framing,
checksum, fields and file behaviour, keeping the old text as a retraction. Mark D.4.3 solved.
The file is CRLF: edit it with the Edit tool.
- 🔑 **The event-file footer's checksum** (D.3.3, open since April) is the same rule:
AUG-CCITT over the footer record from its length `00 1a` through byte 24, stored big-endian,
**70,041 / 70,041** DL2 files. Recorded on `dev` by the decoder session (`8544e9c`,
2026-11-11). Inferred: every record in the event file's tail chain (D.6.13) carries one.
## Testing
TDD. Fixtures go in a dated `tests/fixtures/` directory (force-added if ignored). A small set
covering each shape:
- a closed-records day (BE12844)
- a session with an event (BE12844 #3067–#3068)
- a histogram day (BE8081)
- a Battery Low Exit (BE8081)
- an empty 18-byte file (BE6907)
- a file with calls that left no file (`BE8081321`)
- the clock step back (BE12844 #3155–#3156)
- a histogram + waveform session (`BE8081.MLG`, 2018-02-16)
- the 4 bench files, including the `ach-vs-manual` pair whose text differs
Plus one file with a byte flipped, for the checksum.
The reader, the storage (including that an open record imported twice is stored once), the
timeline cases above and the routes each get tests. The full suite has 16 known failures; read the
failure list before committing.
## Left to the builder
- Model and helper names; the exact JSON shapes of the routes.
- Whether `read_mlg` moves into its own module later.
- What the header record's other bytes hold (all zero on the files seen).
- **Not in this project:** linking a session's events to SFM's stored event ids. Terra-View may
want that later. It needs a matcher, because the events table stores neither the stop time nor
the flag word, and its times moved in 0.32.0 and 0.34.0.
## Later pieces (not this project)
- **The watcher** forwards `.MLG`s with their modified time, and the heartbeat stops sniffing them.
- **Terra-View** shows each unit's timeline, puts "monitoring during the blast" on shot reports,
and takes "last call-in" from SFM.
- **BE6907's extra call-ins:** worth a look at its modem and call-home settings.
-350
View File
@@ -1,350 +0,0 @@
> ## SUPERSEDED 2026-08-25 — the body is a RECORD CHAIN
>
> The tag-dispatch model described in this document — `40 NN` segment headers,
> tagless headers, channel rotation — is **wrong**. It produced nearly-correct
> output only because the block table happens to tile the data sections.
>
> The body is a chain of self-delimiting per-channel records: `off+2` is a
> uint16 BE length, `next = off + 2 + len`, and the chain ends on a record whose
> chan_id is `0x06`. A 3-valued mode enum at `off+8` selects delta / absolute /
> raw-12-bit semantics. `40 NN` is an ordinary int16 BE data block.
>
> See the record-chain section of `docs/instantel_protocol_reference.md` §7.6.1
> and the implementation in `minimateplus/waveform_codec.py`.
>
> Result: all four channels equal length in 1388/1388 files (was 156/1388);
> ASCII sample-count exact 75/75, fully exact 73/75; device PPV 1306/1306.
>
> This document is retained as the reasoning trail.
# Waveform body codec — FULLY DECODED (2026-05-11)
This is the **clean working note** for the body-codec reverse-engineering
effort. It supersedes scattered claims elsewhere when they conflict.
The deep historical record (with retractions, dead ends, and dated
analyses) lives in `docs/instantel_protocol_reference.md §7.6.1`; the
authoritative implementation lives in `minimateplus/waveform_codec.py`.
## TL;DR
**The codec is fully decoded.** Every block type, every channel, every
event in the fixture bundle decodes byte-exact against BW's ASCII
export.
| Block type | Meaning | Verified |
|---|---|---|
| `10 NN` | 4-bit signed nibble deltas | ✅ |
| `20 NN` | int8 signed deltas | ✅ |
| `00 NN` | run-length-encoded zero deltas | ✅ |
| `30 NN` | 12-bit signed packed deltas | ✅ NEW (2026-05-11 late) |
| `40 02` | segment header (anchor pair + prev-channel extension) | ✅ |
Channels rotate **Tran → Vert → Long → MicL** per segment. Each
channel-segment carries ~512 samples (2-sample anchor pair + 508
deltas + 2-sample continuation in next segment's header).
## What decodes byte-exact today
**Every decoded sample across every fixture event matches truth. Zero
divergences.**
| Event | Description | Tran | Vert | Long | Total |
|---|---|---|---|---|---|
| event-a (5-8) | quiet, 3 sec | 3328 ✓ | 3328 ✓ | 3328 ✓ | **9984** |
| event-c (5-8) | quiet, 1 sec | 1280 ✓ | 1280 ✓ | 1280 ✓ | 3840 |
| event-d (5-8) | quiet, 1 sec | 1280 ✓ | 1280 ✓ | 1280 ✓ | 3840 |
| JQ0 (5-11) | Vert-heavy, 3 sec | 3328 ✓ | 3328 ✓ | 3328 ✓ | **9984** |
| V70 (5-11) | Mic-heavy, 3 sec | 3328 ✓ | 3328 ✓ | 3328 ✓ | **9984** |
| SP0 (5-11) | loud all, 3 sec | 2048 ✓ | 1538 ✓ | 1536 ✓ | 5122 |
| SS0 (5-11) | loud-from-start | 734 ✓ | 512 ✓ | 512 ✓ | 1758 |
| SV0 (5-11) | loud-from-start | 1024 ✓ | 578 ✓ | 512 ✓ | 2114 |
| event-b (5-8) | quiet, 2 sec | 512 ✓ | 226 ✓ | 0 | 738 |
That's **47,364 ADC samples decoded byte-exact, zero errors.**
Three full 3-sec events (event-a, JQ0, V70) decode end-to-end across
all three geo channels.
The events where fewer samples are decoded (SP0, SS0, SV0, event-b)
are limited by the walker stopping at certain block-length edge cases,
not by decoder correctness — every sample the walker reaches is
correct.
## What's still open
- **Tail samples on SS0/SV0** — these two events decode all but the
last 1–7 samples per channel (out of 3079). Likely the same
"last segment is truncated" pattern. Minor; doesn't affect the
bulk of the data.
## Sample counts (72,972 byte-exact total)
| Event | Tran | Vert | Long | Status |
|---|---|---|---|---|
| event-a | 3328 | 3328 | 3328 | full |
| event-b | 2304 | 2304 | 2304 | full |
| event-c | 1280 | 1280 | 1280 | full |
| event-d | 1280 | 1280 | 1280 | full |
| JQ0 | 3328 | 3328 | 3328 | full |
| V70 | 3328 | 3328 | 3328 | full |
| SP0 | 3328 | 3328 | 3328 | full |
| SS0 | 3078 | 3072 | 3072 | minus 1–7 tail samples |
| SV0 | 3078 | 3072 | 3072 | minus 1–7 tail samples |
## What's now wired into production (2026-05-11 late)
- **`client.py:_decode_a5_waveform`** — now uses
`decode_a5_frames(a5_frames)` instead of the broken int16 LE decoder.
`event.raw_samples` is populated with int16 ADC counts that flow
through the existing `sfm/event_hdf5.py` scaling pipeline unchanged.
Legacy decoder is preserved as `_decode_a5_waveform_LEGACY` for
reference but is not called.
- **MicL → dB(L) conversion** — exposed as
`waveform_codec.mic_count_to_db(count)`. Verified against BW
display values (count=1 → 81.94 dB; count=813 → 140.14 dB; matches
the V70 mic-heavy fixture exactly).
- **`decode_a5_frames(a5_frames)`** — production entry point that
reconstructs the BW-binary body from A5 frames (via the new
`blastware_file.extract_body_bytes` helper) and runs the verified
codec. Returns the same `raw_samples` dict shape the consumers
already expect.
## What's solved
### Block framing
| Tag | Length | Meaning |
|----------|-----------------------|------------------------------------------|
| `10 NN` | NN/2 + 2 bytes | 4-bit nibble deltas (2 per byte; high |
| | | nibble first; signed 0..7 / 8..F = -8..-1)|
| `20 NN` | NN + 2 bytes | int8 signed deltas (1 per byte) |
| `00 NN` | 2 bytes | RLE: append NN copies of current value |
| `30 NN` | NN*1.5 + 2 in data | 12-bit signed deltas (see below). |
| | section, NN*4 trailer | |
| `40 NN` | 2*NN + 16 bytes | Segment header (NN = prev-channel deltas)|
NN is always a multiple of 4.
**Wide-NN forms.** `10`, `20` *and* `00` all support a 12-bit NN:
when NN would exceed 0xFC the low nibble of the tag byte carries NN's
high nibble, so `NN = ((tag & 0x0F) << 8) | nn_byte`. Confirmed for
`1X`/`2X` in 2026-05-11 and for `0X` (RLE) in 2026-08-25 — e.g.
`01 0c` = a 268-sample zero-delta run.
**`40 NN` is variable width.** NN counts the int16 BE continuation
deltas the header carries for the *previous* channel, so the header is
`2*NN + 16` bytes and every field after the deltas shifts by `2*NN`.
`40 01` (18 B) and `40 03` (22 B) both occur alongside the common
`40 02` (20 B). Confirmed 2026-08-25.
Implementation: `walk_body()` in `minimateplus/waveform_codec.py`.
### 7-byte preamble
```
body[0:3] = 00 02 00 magic
body[3:5] = Tran[0] int16 BE in 16-count units (LSB = 0.005 in/s)
body[5:7] = Tran[1] int16 BE in 16-count units
```
### Tran channel, segment 0
Segment 0 (everything before the first `40 02`) encodes Tran samples
only. Starting from preamble anchors Tran[0] and Tran[1], each block
contributes to a running cumulative:
- `10 NN` → append NN nibble-deltas
- `20 NN` → append NN int8-deltas
- `00 NN` → append NN copies of current value (RLE)
- `40 02` → end segment 0
Verified byte-exact:
| Event | Description | Segment 0 size | Match |
|---|---|---|---|
| `M529LL1A.SP0` | Loud, 0.25 s pretrig | 510 | 510/510 ✓ |
| `M529LL1A.SV0` | Loud from sample 0 | 58 | 58/58 ✓ (stops at first `30 NN`) |
| `M529LL1A.SS0` | Loud from sample 0 | 42 | 42/42 ✓ (stops at first `30 04`) |
| `M529LL1L.JQ0` | Vert-heavy | 510 | 510/510 ✓ |
| `M529LL1L.V70` | Mic-heavy (140 dB) | 510 | 510/510 ✓ |
Implementation: `decode_tran_initial()`.
### Segment header (`40 02`, 20 bytes total) — REWRITTEN 2026-05-11
| Payload offset | Field | Status |
|---|---|---|
| [0:2] | Previous-channel delta — 1st extension sample (int16 BE) | ✅ confirmed |
| [2:4] | Previous-channel delta — 2nd extension sample (int16 BE) | ✅ confirmed |
| [4:6] | Unknown (likely checksum) | ❓ open |
| [6:8] | Byte length to next segment header − 2 (uint16 BE) | ✅ confirmed |
| [8:12] | Monotonic uint32 LE counter (starts ~0x47) | ✅ confirmed |
| [12:14] | Constant `02 00` | ✅ confirmed |
| [14:16] | THIS segment's channel — sample 0 anchor (int16 BE, 16-count units) | ✅ confirmed |
| [16:18] | THIS segment's channel — sample 1 anchor (int16 BE, 16-count units) | ✅ confirmed |
**Key insight (2026-05-11 late):** every segment carries 510 main
samples (2 anchor + 508 deltas) PLUS 2 continuation samples that live
in the NEXT segment header. So each channel-segment effectively spans
512 sample-sets. The continuation lives in the next segment because
the segment header is also a channel-switch point, so it's a natural
place to "extend the channel we're leaving" before "starting the
channel we're entering."
This is the same structure as the body preamble (which carries
Tran[0] and Tran[1] as int16 BE) — every channel uses the same
"2 anchors + delta stream" layout.
## Channel rotation — VERIFIED 2026-05-11
```
(initial body) → Tran samples 0..509 (preamble + delta blocks)
segment 0 hdr ext+anchor → Vert samples 0..511 ← anchor in hdr [14:18]
segment 1 hdr ext+anchor → Long samples 0..511
segment 2 hdr ext+anchor → Mic samples 0..511
segment 3 hdr ext+anchor → Tran samples 510..1021 (continuation)
segment 4 hdr ext+anchor → Vert samples 512..1023
segment 5 hdr ext+anchor → Long samples 512..1023
segment 6 hdr ext+anchor → Mic samples 512..1023
segment 7 hdr ext+anchor → Tran samples 1022..1533
...
```
Implementation: `decode_waveform_v2()` returns
`{"Tran": [...], "Vert": [...], "Long": [...], "MicL": [...]}` with
each channel's samples in 16-count units. All verified ranges in the
TL;DR table above are now locked in by pytest regression tests.
## What's still open
1. **`30 NN` block content.** These blocks appear in high-amplitude
regions (sample-set deltas exceeding what int8 in `20 NN` can
express). The decoder currently steps over them, which loses
precision for the affected samples. Likely a packed multi-byte
delta format (12-bit or 16-bit per delta) — initial guesses didn't
match cleanly, needs more careful analysis.
2. **MicL decoding.** The mic channel's anchor pair appears in the
third segment of each rotation cycle in the same format as the
geo channels, but the BW ASCII export shows mic in dB(L) (~6 dB
quantization steps), so direct integer comparison against ADC
units doesn't work. Need to figure out the ADC-counts → dB(L)
conversion or pull the mic ADC counts from somewhere else in the
file format.
3. **Walker fix for event-b.** The original quiet bundle's event-b
still bails out partway through. Lower priority since the other
7 events walk cleanly.
4. **Variable-prefix segment descriptors** (found 2026-08-25).
3 of 75 ground-truth production events still truncate. The walk
reaches a segment header whose channel-id field is preceded by a
variable-width prefix (2, 4 or 6 bytes observed; the standard
tagless form always has 4). These also carry an `01 00` marker
instead of `02 00`. The marker is not simply an anchor count —
records with `01 00` appear with both 2- and 4-byte anchor fields in
the same file. Examples: `BE12599/N599LPNB.JF0W` @1155,
`BE12599/N599LPWJ.980W` @849, `BE9558/K558LOF2.820W` @1485.
## Segment header: channel id and tagless form — 2026-08-25
The 4-byte field previously read as a "monotonic uint32 LE counter" is
`[channel_id][00][00][segment_index]`, with `0x46`=Tran `0x47`=Vert
`0x48`=Long `0x49`=MicL. Verified on **1697/1697** segment headers in
the ground-truth corpus, zero disagreements. `decode_waveform_v2` now
takes the channel from this field instead of rotation position.
A segment header may also appear **without its `40 NN` tag** — just the
14-byte tail `[field2:2][len:2][channel_id:4][marker:2][anchors:4]`
(the NN=0 case). `is_tagless_segment_header()` detects it from the six
bytes at `[4:10]`.
## Geo scale: full scale is 32000 counts — 2026-08-25
One decoder unit (16 ADC counts) is exactly 0.005 in/s, so Normal range
(10.000 in/s) is `10.0 / (0.005/16)` = **32000** ADC counts. Consumers
that divided by 32768 read every geophone sample 2.34% low. Measured
on 216 channel comparisons: 32768 → 151/216 exact; 32000 → 216/216
exact, worst error 1 LSB.
**Scope — not waveform-specific.** The scale is applied where ADC
counts become physical units, which every event passes through
regardless of source codec:
| source | median ratio ours/device, 32768 | with 32000 |
|---|---|---|
| series-3 waveform (vs ASCII sample table) | 0.9766 | **1.0000** |
| series-3 histogram (vs ASCII PPV, n=1137) | 0.9766 | **1.0000** |
| series-4 Thor IDF (vs device peak, n=1468) | 0.960 | **0.983** |
The four block-framing fixes are waveform-only — `histogram_codec` is
untouched by them.
## Ground-truth corpus (2026-08-25)
Beyond the bundled fixtures, the production waveform store keeps each
event's original Blastware ASCII export at
`<store>/<serial>/<filename>_ASCII.TXT`. 75 series-3 waveform events
have both the BW binary and the ASCII, giving a per-sample regression
corpus far wider than the 9 bundled fixtures. Current standing:
**72 decode exactly** (full length, within 1 LSB — the worst error is
0.0050 in/s, which is exactly 1 LSB of quantization) and 3 truncate
(item 4 above). Zero events have full-length value errors.
## `30 NN` block format — CRACKED 2026-05-11 late
The `30 NN` block carries `NN` 12-bit signed deltas, packed as `NN/4`
groups of 6 bytes each. Within each 6-byte group:
```
bytes [0:2] = 16 bits = 4 × 4-bit "high nibbles" (MSB-first)
bytes [2:6] = 4 × int8 "low bytes"
For k in 0..3:
high_nibble = (header_word >> (12 - 4*k)) & 0xF
raw_12 = (high_nibble << 8) | low_byte[k]
delta[k] = raw_12 - 0x1000 if raw_12 >= 0x800 else raw_12
```
The block's total length is `NN × 1.5 + 2` bytes (tag included). This
is what was tripping up the earlier walker, which used `NN × 4` (the
trailer-section formula) instead.
Why 12-bit and not 16-bit: 12-bit signed range is ±2047, which in
16-count units = ±10.2 in/s — almost exactly the ±10 in/s full-scale
range of the geophone at Normal range. The codec sizes its widest
delta to cover the worst-case sample-to-sample change.
Verified against all 14 `30 NN` blocks across the bundled fixture
events. Every delta decodes byte-exact against BW's ASCII export.
## Test fixtures
Committed under `tests/fixtures/`:
- `decode-re-5-8-26/event-a..event-d/`: original quiet bundle (4 events,
PPV < 1 in/s). These have Tran ≈ 0 throughout, so segment-0 decode
works but the loud-amplitude tests (preamble anchors, `30 NN`) are
uninformative.
- `5-11-26/M529LL1A.{SP0,SS0,SV0}`: loud bundle (PPV 6-7 in/s on all
channels). These cracked the Tran codec.
- `5-11-26/M529LL1L.{JQ0,V70}`: targeted captures. JQ0 is Vert-heavy,
V70 is Mic-heavy (140 dB). These cracked the `00 NN` RLE rule.
Each fixture has a `.TXT` Blastware ASCII export as ground truth.
## Tests
`tests/test_waveform_codec.py` (40 tests, all passing) locks in:
- Block framing (5 tag types with correct lengths).
- Walker contiguity (no gaps or overlaps).
- Segment header parsing (counter monotonicity, fixed-pattern check).
- `decode_tran_initial` against ground-truth Tran samples for all
fixture events.
When you crack the next piece, **add fixture tests against ground-truth
samples** for that piece before moving on. Don't let unverified code
ship without a regression lock-in.
+107
View File
@@ -60,6 +60,7 @@ from minimateplus.framing import build_bw_frame, SESSION_RESET
from minimateplus.client import (
MiniMateClient,
_decode_compliance_config_into,
_encode_compliance_config,
)
from minimateplus.models import DeviceInfo
@@ -461,6 +462,111 @@ def exp_fewer_polls(host: str, port: int) -> tuple[str, str, dict]:
t.disconnect()
# ══════════════════════════════════════════════════════════════════════════════
# EXP6 — Compliance-only write (71×3→72), skip event index + trigger + waveform
# ══════════════════════════════════════════════════════════════════════════════
#
# Blastware's full write sequence: 68→73 | 71×3→72 | 82→83 | 69→74→72
# We want to know: can we write ONLY the compliance block (71×3→72)?
#
# Test procedure:
# 1. Read current compliance config (SUB 1A)
# 2. Patch the "notes" field to a test marker
# 3. Write ONLY 71×3→72 (skip 68, 73, 82, 83, 69, 74, final 72)
# 4. Read back (SUB 1A) and verify the change was written
# 5. Restore original value
#
# If PASS: we can push individual config fields without touching event index,
# trigger config, or waveform data — huge simplification.
# If FAIL: the device needs the full write sequence (may reject partial write).
#
# SAFETY: We restore original data in a finally block. If the restore write
# fails, the device will have the test marker in "notes" — harmless but visible.
_EXP6_MARKER = "[exp6-test]"
def exp_compliance_only(host: str, port: int) -> tuple[str, str, dict]:
"""Write compliance block alone (71×3→72), verify, and restore."""
client, info = connect_client(host, port)
original_raw: Optional[bytes] = None
try:
proto = client._proto
if proto is None:
return "FAIL", "Could not get protocol handle from client", {}
# 1. Read current compliance
print(" Reading current compliance config (SUB 1A)…")
original_raw = proto.read_compliance_config()
print(f" Got {len(original_raw)} bytes of compliance config")
# Find current notes value for display
info_obj = DeviceInfo()
_decode_compliance_config_into(original_raw, info_obj)
cc = info_obj.compliance_config
orig_notes = cc.notes if cc else "(unknown)"
print(f" Current notes field: {orig_notes!r}")
# 2. Build modified payload with test marker in notes
test_notes = _EXP6_MARKER
modified_raw = _encode_compliance_config(
original_raw,
notes=test_notes,
)
print(f" Encoded modified compliance payload ({len(modified_raw)} bytes)")
print(f" Patching notes: {orig_notes!r} → {test_notes!r}")
# 3. Write ONLY the compliance block: 71×3 → 72
print(" Writing compliance ONLY (71×3→72) — skipping 68/73/82/83/69/74…")
proto.write_compliance_config_raw(modified_raw)
print(" Write complete — device acked 71×3→72")
# 4. Read back and verify
print(" Reading back compliance config to verify…")
readback_raw = proto.read_compliance_config()
readback_info = DeviceInfo()
_decode_compliance_config_into(readback_raw, readback_info)
rb_cc = readback_info.compliance_config
readback_notes = rb_cc.notes if rb_cc else "(decode failed)"
print(f" Read-back notes: {readback_notes!r}")
write_worked = (readback_notes == test_notes)
print(f" Write verified: {write_worked}")
details = {
"original_notes": orig_notes,
"written_notes": test_notes,
"readback_notes": readback_notes,
"write_verified": write_worked,
}
if write_worked:
return "PASS", "Compliance-only write works! No event index or trigger writes needed.", details
else:
return "FAIL", f"Write was not reflected in read-back (got {readback_notes!r})", details
except ProtocolError as exc:
return "FAIL", f"Protocol error: {exc}", {}
finally:
# Restore original compliance data regardless of outcome
if original_raw is not None:
print(" Restoring original compliance config…")
try:
proto2 = client._proto
if proto2:
proto2.write_compliance_config_raw(
_encode_compliance_config(original_raw) # no-op patch = verbatim
)
print(" Restore complete")
else:
print(" WARNING: protocol handle gone — could not restore")
except Exception as exc_r:
print(f" WARNING: restore failed: {exc_r}")
client.close()
# ══════════════════════════════════════════════════════════════════════════════
# Registry + main
# ══════════════════════════════════════════════════════════════════════════════
EXPERIMENTS = {
@@ -469,6 +575,7 @@ EXPERIMENTS = {
"no_5a": ("EXP3", exp_no_5a, "Event record (0C) without bulk waveform (5A)"),
"skip_1e": ("EXP4", exp_skip_1e, "0A/0C with cached key — skip initial 1E"),
"fewer_polls": ("EXP5", exp_fewer_polls, "1 POLL before 5A instead of Blastware's 3"),
"compliance_only": ("EXP6", exp_compliance_only, "Compliance-only write (71×3→72), no other blocks"),
}
-48
View File
@@ -1,48 +0,0 @@
"""
micromate — Instantel Micromate (Series IV) device library.
Sibling of ``minimateplus`` (the Series III library). Currently scoped to
the offline-file ingest path used by thor-watcher: parsing the per-event
``.IDFH``/``.IDFW`` ASCII text sidecars Thor's exporter writes alongside
each binary event file, and wrapping the parsed data in typed event
records.
Live-device support (TCP protocol, frame parsing, real-time monitoring)
is deferred — when we add it, it lands here as ``transport.py`` /
``framing.py`` / ``protocol.py`` / ``client.py``, mirroring the
``minimateplus`` package layout.
Typical usage (offline file ingest):
from micromate import IdfEvent, parse_idf_report
text = open("UM11719_20231219162723.IDFW.txt").read()
rep = parse_idf_report(text) # dict
event = IdfEvent.from_report(rep, "UM11719_20231219162723.IDFW")
print(event.serial, event.peaks.transverse_ips, event.mic_pspl_dbl)
"""
from .idf_ascii_report import (
parse_event_filename,
parse_idf_report,
serial_from_filename,
)
from .models import (
IdfEvent,
IdfPeaks,
IdfProjectInfo,
IdfReport,
IdfSensorCheck,
)
__version__ = "0.1.0"
__all__ = [
"IdfEvent",
"IdfPeaks",
"IdfProjectInfo",
"IdfReport",
"IdfSensorCheck",
"parse_event_filename",
"parse_idf_report",
"serial_from_filename",
]
-675
View File
@@ -1,675 +0,0 @@
"""
client.py — high-level API for a live Micromate (Series IV).
Owns the transport, turns raw payloads into models. Read-only, like the layer
below it: nothing here writes, erases, or changes monitoring state, and the
protocol's opcode gate (`micromate.opcodes`) enforces that in code.
with MicromateClient(TcpTransport("63.45.161.30", 9034)) as mm:
info = mm.connect()
print(info) # UM12947 MM/ISEE/S/IO blastware fw idle
print(mm.get_state()) # idle 2026-09-25 01:14:05 3.80 V memory 0.4% used
for name in mm.list_setups():
print(name)
The response layout, measured rather than assumed
-------------------------------------------------
**Every response carries an 11-byte prefix, and the content starts at
``data[11]``.** That one rule covers every command.
⚠ **``data[0]`` looks like the content length and is only its low byte.** A
2,092-byte setup block (`SUB 0x1A`) reports 44, and a 1,024-byte download chunk
reports 0. It happens to be right for every response shorter than 256 bytes,
which is most of them — so it reads as a working length field right up until it
silently loses 2,048 bytes. There is no high byte anywhere in the prefix; it is
``length & 0xFF`` and nothing more.
This is the same trap as ``MicromateFrame.probe_length``, in a different place,
and it is now the third time a length in this protocol has been read too narrow.
**Take the content as ``data[11:]`` and let the frame's own length bound it.**
"""
from __future__ import annotations
import datetime
import logging
import math
import os
import struct
from typing import Optional
from minimateplus.transport import BaseTransport
from .models import (
MicromateDeviceInfo,
MicromateEventRef,
MicromateRunState,
MicromateSetup,
MicromateState,
)
from .protocol import MicromateProtocol, ProtocolError
from .schedule import SCHEDULE_PATH
from .setup_block import decode_setup
log = logging.getLogger(__name__)
# The content of every response begins here; the first 11 bytes are a prefix
# whose only decoded field is an unreliable low-byte length (see module docstring).
CONTENT = 11
# Field offsets, relative to the start of content. Sources are named because
# two of them disagree with docs/micromate_protocol_reference.md.
_STATE_FLAG = 0 # 0x49: 0x00 idle, 0x02 monitoring
# 0x06 storage range. content[0:4] is the event count: 3/3 against the chain
# walk, and THOR's ReadEventRecordCount agrees. content[4:8] is very likely
# the monitor-log count -- graded a strong candidate, not settled, so not exposed.
_SR_EVENT_COUNT = slice(0, 4)
_MS_FLAG = 1 # 0x1C: monitoring flag — test NON-ZERO
_MS_DAY, _MS_MONTH, _MS_YEAR = 2, 3, slice(4, 6)
_MS_UNKNOWN_6 = 6 # ⚠ sub-second tick (~4020/s, step 4, 64 ms wrap) — NOT the hour
_MS_HOUR, _MS_MIN, _MS_SEC = 7, 8, 9
_MS_BATTERY = slice(34, 36) # uint16 BE, volts × 100
_MS_MEM_TOTAL = slice(36, 40) # uint32 BE
_MS_MEM_FREE = slice(40, 44) # uint32 BE
# `SUB 0x0C` record, relative to content. Established against 7 events across
# both firmware lines.
_REC_DAY, _REC_MONTH, _REC_YEAR = 0, 1, slice(2, 4)
_REC_UNKNOWN_4 = 4 # ⚠ same shape as 0x1C's content[6]; undecoded
_REC_HOUR, _REC_MIN, _REC_SEC = 5, 6, 7
_REC_TYPE = 11 # 0x07 waveform, 0x08 histogram
_REC_LOCATION = 12
_REC_SETUP = 34
_REC_SERIAL = 76
_RECORD_TYPES = {0x07: "waveform", 0x08: "histogram"}
# The channel labels the record carries, in the order they appear. The peak
# float sits `label + 6`; the peak vector sum sits 12 bytes BEFORE "Tran".
_REC_CHANNELS = (b"Tran", b"Vert", b"Long", b"Mic")
_REC_PVS_BACK = 12
# A chain walk terminates on an all-zero key. The ceilings below are guards
# against a device cursor that never advances, not fleet limits.
_NULL_KEY = bytes(4)
_MAX_EVENTS = 4096
# A setup-list walk that does not terminate is a bug, not a big fleet. The
# bench unit holds 22 setups; this is a generous ceiling, not a limit.
_MAX_SETUPS = 512
def _content(data: bytes) -> bytes:
"""Strip the 11-byte response prefix."""
return data[CONTENT:] if len(data) > CONTENT else b""
def _cstring(buf: bytes, offset: int = 0) -> str:
"""A null-terminated ASCII run, stripped."""
return buf[offset:].split(b"\x00")[0].decode("ascii", "replace").strip()
class DecodeMismatch(ProtocolError):
"""Our decoded peak disagrees with the one the device computed itself."""
class MicromateClient:
"""High-level read-only client for one Micromate.
Owns the transport, unlike ``MicromateProtocol``, which borrows it.
"""
def __init__(
self,
transport: BaseTransport,
recv_timeout: float = 10.0,
strict_checksums: bool = True,
) -> None:
self._transport = transport
self._proto = MicromateProtocol(
transport, recv_timeout=recv_timeout, strict_checksums=strict_checksums
)
self._firmware_line: Optional[str] = None
self._serial: Optional[str] = None
# ── Lifecycle ─────────────────────────────────────────────────────────────
def open(self) -> None:
self._transport.connect()
def close(self) -> None:
self._transport.disconnect()
def is_open(self) -> bool:
# `is_connected` is a PROPERTY on BaseTransport. Calling it raised
# TypeError on every real transport; only a test double that defined
# it as a method hid that.
return bool(self._transport.is_connected)
def __enter__(self) -> "MicromateClient":
self.open()
return self
def __exit__(self, *_) -> None:
self.close()
@property
def protocol(self) -> MicromateProtocol:
"""The wire layer, for anything this class does not wrap yet."""
return self._proto
# ── Identity ──────────────────────────────────────────────────────────────
def connect(self, *, with_active_setup: bool = True) -> MicromateDeviceInfo:
"""`POLL → SERIAL → state`, plus the active setup name.
⚠ **This is deliberately not Thor's full preamble.** Thor sends
`POLL → SERIAL → 0x49 → POLL` and the client spec said to copy it
verbatim on the grounds that it is known-good. Measuring all 8 captured
sessions showed the only invariant is that a session **opens with
POLL** — the four-command form appears in 3 of 8 and is Thor's
*connection check*, run where it wants to refresh what it displays. The
trailing POLL is a repeat of the first.
So this sends the three reads that actually gather something. Dropping
the fourth is a judgement call on measured evidence, not a proof that
nothing depends on it; if a unit ever refuses the next command after a
cold connect, put it back and say so in the protocol reference.
`SUB 0x01` (device info) is **not** read. Thor never reads it in any
captured session, its field layout is unmapped beyond eight `1.0f`
floats, and `firmware_line` — the one thing we would want from it — comes
free from the flags byte of any response.
"""
poll = self._proto.poll()
self._firmware_line = poll.firmware_line
manufacturer, model = self._parse_poll(poll.data)
serial = _cstring(_content(self._proto.read_serial()))
self._serial = serial
monitoring = self._parse_state(self._proto.read_state())
info = MicromateDeviceInfo(
serial=serial,
manufacturer=manufacturer,
model=model,
firmware_line=poll.firmware_line,
monitoring=monitoring,
)
if with_active_setup:
try:
info.active_setup = self.get_active_setup()
except ProtocolError as e:
# Not worth failing a connect over: a unit with no setup loaded
# is a real state, and the caller can still read everything else.
log.warning("active setup unreadable: %s", e)
log.info("connected: %s", info)
return info
@staticmethod
def _parse_poll(data: bytes) -> tuple[Optional[str], Optional[str]]:
"""Manufacturer and model out of the POLL block.
`Instantel` sits at content[4] and the model at content[26], with 13
binary bytes between them.
⚠ A generic "find the printable runs" scan does **not** work here, which
cost a test failure before it cost anything worse. content[3] is `0x50`
— printable as `P` — sitting immediately before `Instantel`, so a run
scan returns `PInstantel`. Nothing distinguishes a length or tag byte
from text by inspection.
So: the manufacturer comes from a fixed offset, and the model is found by
searching for `MM/`. That anchor is structural rather than positional,
which matters because the model string **differs by firmware line** —
`MM/ISEE/S/IO` on the Blastware build, `MM/ISEE/S` on the Thor build —
and only its tail changes.
"""
c = _content(data)
manufacturer = _cstring(c, 4) or None
idx = c.find(b"MM/")
model = _cstring(c, idx) if idx >= 0 else None
return manufacturer, model
@staticmethod
def _parse_state(data: bytes) -> Optional[bool]:
"""`SUB 0x49` content[0]: 0x00 idle, 0x02 monitoring.
⚠ Tested for non-zero, never against `0x02`. The sibling flag in
`SUB 0x1C` has read both `0x0E` and `0x0C` while monitoring, so this
family of flags is not a stable enum.
"""
c = _content(data)
return bool(c[_STATE_FLAG]) if c else None
# ── State ─────────────────────────────────────────────────────────────────
def get_state(self) -> MicromateState:
"""`SUB 0x1C` — monitoring, device clock, battery, memory.
⚠ Every offset here is **forward from the start of content**, never
backward from the end. Series III reads battery and memory from the end
of this block, and this block is **4 bytes longer on the Thor firmware
line** — applying from-the-end offsets to a `11.0BD` unit yields a
battery voltage of 577.92 V. The four extra bytes are trailing, so
from-the-start offsets hold for both lines.
✅ **Confirmed on `11.0BD` 2026-09-30.** UM20147 read back 3.55 V and
a clock correct to the second over USB, so the from-the-start offsets do
survive the four extra trailing bytes. Had they not, the battery would
have read 577.92 V — which is what makes this cheap to check.
"""
data = self._proto.read_monitor_status()
c = _content(data)
if len(c) < 44:
raise ProtocolError(
f"monitor status content is {len(c)} B, need at least 44"
)
battery = int.from_bytes(c[_MS_BATTERY], "big") / 100.0
return MicromateState(
monitoring=bool(c[_MS_FLAG]),
device_time=self._parse_clock(c),
battery_volts=battery,
memory_total_bytes=int.from_bytes(c[_MS_MEM_TOTAL], "big"),
memory_free_bytes=int.from_bytes(c[_MS_MEM_FREE], "big"),
raw=data,
)
def get_event_count(self) -> int:
"""`SUB 0x06` -- events stored. One read; no chain walk."""
c = _content(self._proto.read_storage_range())
if len(c) < 4:
raise ProtocolError(f"storage range content is {len(c)} B, need at least 4")
return int.from_bytes(c[_SR_EVENT_COUNT], "big")
def read_unsolicited(self) -> bytes:
"""Whatever the unit sent unprompted. **Sends nothing.**
One transport read. Bytes between commands are noise to the protocol
(every request resets the parser), so reading them here takes nothing
the protocol needs. A session calls this while idle to notice
RADIO RING without waiting for its next keep-alive.
"""
return self._transport.read(4096)
@staticmethod
def _parse_clock(c: bytes) -> Optional[datetime.datetime]:
"""The unit's own clock, in its own local time.
⚠ **content[6] is not part of the time.** The layout is day, month,
year, *one unidentified byte*, then h/m/s — so the hour is at content[7].
The protocol reference's `SUB 0x1C` section has this right and names
`data[17]` as unidentified; its one-line summary in the divergences list
("day/month/year/h/m/s at `data[13:21]`") reads as six contiguous fields
and is the version worth not trusting.
Re-measured here across three captures: content[6] read 32, 100 and 116,
none a valid hour, while content[7:10] gave 19:12:25, 19:13:34 and
01:14:05 against capture filenames stamped 19:12:14, 19:12:14 and
01:14:03 — each seconds to a minute after its session opened, which is
what a device clock should do.
content[6] is undecoded and deliberately not exposed.
"""
try:
return datetime.datetime(
year=int.from_bytes(c[_MS_YEAR], "big"),
month=c[_MS_MONTH],
day=c[_MS_DAY],
hour=c[_MS_HOUR],
minute=c[_MS_MIN],
second=c[_MS_SEC],
)
except ValueError as e:
# A unit with a dead clock battery reports an impossible date. That
# is information, not a reason to fail the whole state read.
log.warning("device clock unreadable (%s): %s", e, c[2:10].hex(" "))
return None
# ── Setups ────────────────────────────────────────────────────────────────
def get_active_setup(self) -> str:
"""`SUB 0x41` — the loaded `.MMB` file name, e.g. `TEST1.mmb`."""
return _cstring(_content(self._proto.read_active_setup_name()))
def get_active_setup_raw(self) -> str:
"""The `0x41` name exactly as stored, up to its NUL -- NOT stripped, so a
setup push writes back the very name the unit holds."""
return _content(self._proto.read_active_setup_name()).split(b"\x00")[0].decode("ascii", "replace")
def get_prefs_content(self) -> bytes:
"""`SUB 0x08` -- the preferences block's content (a setup push sends it back)."""
return _content(self._proto.read_event_index())
def get_trigger_content(self) -> bytes:
"""`SUB 0x2E` -- the trigger block's content (a setup push sends it back)."""
return _content(self._proto.read_trigger_config())
def get_setup_content(self) -> bytes:
"""`SUB 0x1A` -- the setup block's content, undecoded (2,092 B, CRC last).
⚠ The keypad's edit buffer: unsaved menu edits come back too."""
return _content(self._proto.read_compliance_config())
def read_schedule(self) -> bytes:
"""`schedule.dat`, read-only (`micromate.schedule.parse_schedule` reads it)."""
return self._proto.read_file(SCHEDULE_PATH)
def get_setup(self, *, verify: bool = True) -> MicromateSetup:
"""`SUB 0x1A` — what the unit is set to, decoded. One read.
Raises ``SetupChecksumError`` if the block's CRC fails, unless
``verify=False``. Offsets and what is deliberately not decoded are in
``micromate/setup_block.py``.
⚠ This reads the keypad's EDIT BUFFER: if someone is in the unit's setup
menu, unsaved values come back.
"""
return decode_setup(_content(self._proto.read_compliance_config()), verify=verify)
def list_setups(self) -> list[str]:
"""`0x3F` then `0x40`… — every setup file stored on the unit.
A cursor walk: the device holds the position, so the same `0x40` request
returns the next name. **An empty name terminates the list** — it is
not an error and not a real setup.
Measured on the bench unit: 23 responses, 22 names then the empty one,
`factory.MMB` first through `TEST1.mmb` last.
"""
names: list[str] = []
raw = self._proto.read_first_setup()
for _ in range(_MAX_SETUPS):
name = _cstring(_content(raw))
if not name:
return names
names.append(name)
raw = self._proto.read_next_setup()
raise ProtocolError(
f"setup list did not terminate after {_MAX_SETUPS} entries — the "
f"device cursor is not advancing"
)
# ── Events ────────────────────────────────────────────────────────────────
def serial(self, *, refresh: bool = False) -> str:
"""The unit's serial, cached from `connect()` or read on demand.
Needed by anything that handles an event, because an event key is
ambiguous without it — see `MicromateEventRef`.
`refresh=True` forces a fresh `0x15` read. A change operation passes it
right before writing, so the identity check never runs against a serial
cached from an earlier call-up (a modem may have moved to another unit).
"""
if refresh or self._serial is None:
self._serial = _cstring(_content(self._proto.read_serial()))
return self._serial
# Anything else reads unknown(0x..): the safe default, which the change path refuses.
_RUN_STATES = {0x00: "idle", 0x02: "monitoring", 0x03: "calling_home"}
def get_call_home_content(self) -> bytes:
"""The `0x2C` call-home block's 126-byte content (bit 0 of [5] is the
enable, [6:46] the dial string; [118:120] is unit-maintained)."""
return _content(self.protocol.read_call_home_config())
def read_run_state(self) -> MicromateRunState:
"""`SUB 0x49` -> the unit's run state, with the in-call-home value kept
(connect()'s `monitoring` bool flattens 0x03 into True)."""
c = _content(self._proto.read_state())
if not c:
raise ProtocolError("0x49 state reply has no content")
code = c[_STATE_FLAG]
return MicromateRunState(code, self._RUN_STATES.get(code, f"unknown(0x{code:02X})"))
def list_events(self, *, with_records: bool = True) -> list[MicromateEventRef]:
"""Walk the event chain. `0x93 → 1E`, then `0x93 → 1F` until the sentinel.
THOR sends `0x93` before **every** chain read, and this mirrors that.
The chain ends on an all-zero key.
⚠ `with_records=True` costs **one extra round trip per event** for the
`0x0C` read, and over cellular a round trip is ~0.65 s regardless of
size. On a unit with 40 events that is the difference between ~52 s and
~78 s. Pass False when you only need "what is here and how big" — but
note the **record is where the type and timestamp live**, so without it
`ref.filename` is None and `get_event()` cannot pick a suffix.
⚠ **To download, prefer `iter_events()`.** This walks the whole chain
first; THOR interleaves, downloading each event before advancing.
`0x5A` addresses an event by key, so downloading afterwards *should*
work — but "should" is doing real work in that sentence, and the
interleaved order is the one with captures behind it. See
`iter_events()`.
"""
serial = self.serial()
refs: list[MicromateEventRef] = []
for i in range(_MAX_EVENTS):
self._proto.arm_event()
raw = (self._proto.read_event_first() if i == 0
else self._proto.read_event_next())
c = _content(raw)
if len(c) < 8:
raise ProtocolError(
f"chain entry {i}: {len(c)} B of content, need 8 (key + size)"
)
key, size = c[0:4], int.from_bytes(c[4:8], "big")
if key == _NULL_KEY:
return refs # the sentinel, not an error
ref = MicromateEventRef(index=i, key=key, size=size, serial=serial)
if with_records:
self._read_record_into(ref)
refs.append(ref)
raise ProtocolError(
f"event chain did not terminate after {_MAX_EVENTS} entries — the "
f"device cursor is not advancing"
)
def iter_events(self, *, with_records: bool = True):
"""Walk the chain, yielding each event **at the cursor position THOR uses.**
for ref in mm.iter_events():
if ref.is_histogram:
continue
data = mm.download_event(ref) # ← safe here
Why this exists alongside `list_events()`: THOR's captured order is
0x93 → 1E → 0C → 5A×n → 0x93 → 1F → 0C → 5A×n → …
— it downloads each event *before* advancing the chain. `list_events()`
walks to the end first, which is fine for browsing (the browse walk is
separately attested) but means a later download happens with the device
cursor parked past the event. `0x5A` is key-addressed, so it very
probably does not care; nothing observed says it does, and nothing
observed says it does not.
Downloading inside this loop reproduces THOR's sequence exactly, so it
is the path to use when it matters. ⚠ Do not advance the generator
before finishing with the event it yielded.
"""
serial = self.serial()
for i in range(_MAX_EVENTS):
self._proto.arm_event()
raw = (self._proto.read_event_first() if i == 0
else self._proto.read_event_next())
c = _content(raw)
if len(c) < 8:
raise ProtocolError(
f"chain entry {i}: {len(c)} B of content, need 8 (key + size)"
)
key, size = c[0:4], int.from_bytes(c[4:8], "big")
if key == _NULL_KEY:
return
ref = MicromateEventRef(index=i, key=key, size=size, serial=serial)
if with_records:
self._read_record_into(ref)
yield ref
raise ProtocolError(
f"event chain did not terminate after {_MAX_EVENTS} entries — the "
f"device cursor is not advancing"
)
def _read_record_into(self, ref: MicromateEventRef) -> None:
"""`SUB 0x0C` — 210 B of content: timestamp, type, names, peaks."""
raw = self._proto.read_event_record(ref.key)
c = _content(raw)
if len(c) <= _REC_SERIAL:
raise ProtocolError(f"event record is {len(c)} B, too short to decode")
ref.raw_record = raw
ref.record_type = _RECORD_TYPES.get(c[_REC_TYPE])
if ref.record_type is None:
# Worth saying out loud rather than filing the event as a waveform:
# the suffix decides which codec runs.
log.warning("event %s: unknown record type 0x%02x at content[%d]",
ref.key_hex, c[_REC_TYPE], _REC_TYPE)
try:
ref.timestamp = datetime.datetime(
year=int.from_bytes(c[_REC_YEAR], "big"),
month=c[_REC_MONTH], day=c[_REC_DAY],
hour=c[_REC_HOUR], minute=c[_REC_MIN], second=c[_REC_SEC],
)
except ValueError as e:
log.warning("event %s: bad timestamp (%s): %s",
ref.key_hex, e, c[:8].hex(" "))
ref.sensor_location = _cstring(c, _REC_LOCATION) or None
ref.setup = _cstring(c, _REC_SETUP) or None
# Prefer the record's own serial over the cached one — they have always
# agreed, but the record is the event's own account of where it came from.
if rec_serial := _cstring(c, _REC_SERIAL):
ref.serial = rec_serial
peaks: dict[str, float] = {}
for label in _REC_CHANNELS:
i = c.find(label)
if i < 0 or i + len(label) + 10 > len(c):
continue
peaks[label.decode()] = struct.unpack(
">f", c[i + len(label) + 2: i + len(label) + 6])[0]
ref.peaks_ips = peaks or None
tran = c.find(b"Tran")
if tran >= _REC_PVS_BACK:
ref.peak_vector_sum_ips = struct.unpack(
">f", c[tran - _REC_PVS_BACK: tran - _REC_PVS_BACK + 4])[0]
def download_event(self, ref: MicromateEventRef, *,
chunk_size: Optional[int] = None) -> bytes:
"""The raw `.IDFW`/`.IDFH` bytes, exactly as THOR would have stored them.
Feeds `micromate.idf_file.read_idf_file()` and `/db/import/idf_file`
unchanged — no new codec work is needed for a directly downloaded event.
`chunk_size` defaults to the measured device ceiling (16,384 B), which is
16x THOR's 1024 and therefore ~14x fewer round trips on a large event.
Pass `THOR_CHUNK_SIZE` to reproduce THOR's wire traffic exactly, or a
smaller value on a link where big responses are not surviving.
"""
kw = {} if chunk_size is None else {"chunk_size": chunk_size}
return self._proto.read_event_file(ref.key, ref.size, **kw)
def get_event(self, ref: MicromateEventRef, *, verify: bool = True,
tolerance: float = 0.01, chunk_size: Optional[int] = None):
"""Download and decode one event.
Returns the codec's `IdfReadResult`. Needs `ref.record_type`, since
`read_idf_file()` dispatches on the filename suffix and there is no
filename on the wire — so call `list_events(with_records=True)` first.
⚠ `verify=True` re-computes the **peak vector sum** from the decoded
samples and compares it against the float the *device* put in the `0x0C`
record. Those are two independent computations over the same samples —
the device's from its own firmware, ours from our codec — so a
disagreement means our decode is wrong. Measured agreement on the bench
events is **0.000%**.
This is cheap insurance in a codebase whose decode failures have
historically been *silent*: unhandled block tags shorten a channel and
nothing raises. ⚠ It is a decode-correctness check, **not** a
truncation detector — a channel cut after its peak still yields the
right PVS.
Histograms are not verified: `samples` is empty for them.
"""
return self.fetch_event(ref, verify=verify, tolerance=tolerance,
chunk_size=chunk_size)[1]
def fetch_event(self, ref: MicromateEventRef, *, verify: bool = True,
tolerance: float = 0.01, chunk_size: Optional[int] = None):
"""`get_event()`, returning the raw bytes too: `(blob, result)`.
For a caller that stores the file AND wants the self-check: the bytes go
to the waveform store unchanged, and a DecodeMismatch stops them being
stored at all.
"""
if not ref.record_type:
raise ValueError(
f"event {ref.key_hex}: record_type is unknown, so the codec "
f"cannot be dispatched. Use list_events(with_records=True)."
)
blob = self.download_event(ref, chunk_size=chunk_size)
import tempfile
from .idf_file import read_idf_file
# read_idf_file dispatches on the suffix, so the bytes need a name.
with tempfile.NamedTemporaryFile(suffix=ref.suffix, delete=False) as f:
f.write(blob)
tmp = f.name
try:
result = read_idf_file(tmp)
finally:
os.unlink(tmp)
if verify and not ref.is_histogram:
err = self.decode_error(ref, result)
if err is not None and abs(err) > tolerance:
raise DecodeMismatch(
f"event {ref.uid}: decoded peak vector sum differs from the "
f"device's own by {100 * err:+.3f}% (tolerance "
f"{100 * tolerance:.1f}%) — the decode is suspect, not the "
f"device. Stored {ref.peak_vector_sum_ips:.5f} in/s."
)
if err is not None:
log.debug("event %s: PVS agrees to %+.4f%%", ref.uid, 100 * err)
return blob, result
@staticmethod
def decode_error(ref: MicromateEventRef, result) -> Optional[float]:
"""Relative error between our decoded PVS and the device's stored one.
None when either side is unavailable. Positive means the device's
figure is higher than ours.
"""
from .idf_file import geo_count_to_ips
stored = ref.peak_vector_sum_ips
if not stored or not getattr(result, "samples", None):
return None
ch = {k.lower(): v for k, v in result.samples.items()}
try:
t, v, l = ch["tran"], ch["vert"], ch["long"]
except KeyError:
return None
n = min(len(t), len(v), len(l))
if not n:
return None
pvs = max(
math.sqrt(geo_count_to_ips(t[i]) ** 2
+ geo_count_to_ips(v[i]) ** 2
+ geo_count_to_ips(l[i]) ** 2)
for i in range(n)
)
return (stored - pvs) / pvs if pvs else None
-330
View File
@@ -1,330 +0,0 @@
"""
framing.py — frame codec for the Instantel Micromate (Series IV) wire protocol.
A Micromate answers Series III *command* frames, so the request side looks
familiar. The framing underneath is not the same, and the differences are all
of the kind that produce a silently-ignored frame rather than an error:
Series III response: [DLE 0x10] [STX 0x02] … [chk] [ETX 0x03]
Micromate response: [STX 0x02] … [chk] [ETX 0x03]
^ no leading DLE
That missing byte is why `minimateplus.framing.S3FrameParser` returns *nothing*
on Micromate traffic — it locates frames by scanning for `DLE STX`, which never
occurs. A capture holding 12 acknowledged writes reads as 12 unanswered
requests.
De-stuffed payload layout (both directions):
request response
[0] CMD 0x10 [0] CMD 0x00
[1] flags 0x00 [1] flags 0xC5 / 0x03 ← firmware line
[2] SUB [2] SUB 0xFF − request_SUB
[3] 0x00 [3] PAGE_HI
[4] offset_hi [4] PAGE_LO
[5] offset_lo [5+] data
[6:16] params (10 bytes)
Everything below was established against the 251 request and 251 response
frames in `bridges/captures/9-24-26 - micromate2/` (UM12947, firmware 11.0CB).
Where a rule is asserted, the number of frames it was checked on is given — the
two rules that look like small details cost 26% and 22% of frames respectively
when guessed wrong, so the counts are the point.
"""
from __future__ import annotations
from dataclasses import dataclass
from typing import Optional
# ── Protocol byte constants ───────────────────────────────────────────────────
DLE = 0x10 # Data Link Escape
STX = 0x02 # Start of text — begins a frame
ETX = 0x03 # End of text — ends a frame
ACK = 0x41 # Frame-start marker on the request side
MM_CMD = 0x10 # payload[0] in a request
MM_RSP_CMD = 0x00 # payload[0] in a response
# payload[1] of a response identifies the firmware line it came from.
# ⚠ Two units, one of each — a strong hypothesis, not a proven encoding.
FLAGS_BLASTWARE = 0xC5 # the 11.0CB line (UM12947)
FLAGS_THOR = 0x03 # the 11.0BD line (UM20147)
# ⚠ THE ESCAPE SET. A Micromate escapes exactly these four byte values,
# prefixing each with a DLE — and nothing else. Established by re-stuffing
# every captured frame and comparing to the wire: 251/251 responses and 251/251
# requests reproduce byte-for-byte with this set, and no other candidate set
# reproduces even 200 of either.
#
# The two near-misses are worth naming, because both look plausible:
# * `{0x10}` alone — the Series III rule — reproduces 130/251 responses and
# 177/251 requests.
# * adding ACK (0x41) reproduces only 196/251 responses: a literal 0x41 in
# the data is NOT escaped.
_ESCAPED = frozenset({STX, ETX, 0x04, DLE})
# A response header is 5 bytes; a frame must also carry its checksum.
_MIN_PAYLOAD = 5
_REQUEST_PAYLOAD_SIZE = 16
# ── Stuffing ──────────────────────────────────────────────────────────────────
def stuff(data: bytes) -> bytes:
"""Escape every byte the Micromate escapes: `XX` → `10 XX` for the four."""
out = bytearray()
for b in data:
if b in _ESCAPED:
out.append(DLE)
out.append(b)
return bytes(out)
def unstuff(data: bytes) -> bytes:
"""Reverse `stuff()`: `10 XX` → `XX`, for any XX.
Uniform, with no inner-frame carve-out — which is a real simplification
over Series III, where `DLE+ETX` inside a frame is literal data that must
survive de-stuffing. Since only four byte values are ever escaped, taking
*any* `10 XX` as `XX` is exact rather than merely convenient.
"""
out = bytearray()
i = 0
while i < len(data):
if data[i] == DLE and i + 1 < len(data):
out.append(data[i + 1])
i += 2
else:
out.append(data[i])
i += 1
return bytes(out)
# ── Checksum ──────────────────────────────────────────────────────────────────
def checksum(payload: bytes) -> int:
"""SUM8 of the **de-stuffed** payload, mod 256. 251/251 both directions.
⚠ Do NOT exclude `0x10` bytes from this sum. The DLE-aware checksum that
Series III uses for its `5A` and write frames is the right answer to a
*different* question: it pairs with Series III de-stuffing, which leaves
escaped bytes in the payload as two bytes. De-stuffing uniformly already
removes the DLE, so excluding `0x10` as well subtracts the correction
twice.
That combination — uniform de-stuffing *and* an exclusive sum — is what
`scratch/mm_frame_parse.py` shipped with. It disagrees with the wire on
**55 of 251** captured response frames, all of them frames whose payload
holds a literal `0x10`. The script only ever looked correct because it
accepts a frame that matches *either* rule, so it reported those 55 as
plain SUM8 and never flagged one bad.
"""
return sum(payload) & 0xFF
# ── Request builder ───────────────────────────────────────────────────────────
def build_request(sub: int, offset: int = 0, params: bytes = bytes(10), data: bytes = b"") -> bytes:
"""Build a host→unit command frame.
⚠ Do **not** substitute `minimateplus.framing.build_bw_frame()` here, even
though the payload layout is identical. That builder escaped only `0x10`,
so it reproduced just **161 of Thor's 218** captured read frames. (Since
2026-10-26 it escapes the same four values -- a MiniMate wants them too -- but
the Micromate framing differs in other ways; keep the two builders apart.) The 57 it
gets wrong are not edge cases:
* every `SUB 0x5A` bulk download — `offset = 0x0400` puts a literal
`0x04` in `offset_hi`, which must go out as `10 04`
* `SUB 0x47` (scheduler enable), whose params carry a `0x03`
An unescaped `0x03` or `0x04` reads as a frame terminator, so the unit sees
a truncated frame and simply does not answer. That is indistinguishable
from a dead unit, and event download would have hit it on the first try.
With the correct escape set this builder reproduces **218/218**.
Args:
sub: command SUB byte.
offset: uint16 at payload[4:5]. Micromate reads are single-step —
Thor asks for `0xFFFF` and gets the whole block — so this is
usually `0xFFFF`, not Series III's probe-then-data pair.
params: exactly 10 bytes at payload[6:16].
data: the write section after params (empty for every read and for
write confirms). Escaped and checksummed exactly like the rest
of the payload -- reproduces all 33 data-carrying THOR frames.
A `0x10` inside `params` is fine and needs no special handling: Thor sends
`SUB 0x5A` with `params = 00 00 10 00 …` and the wire carries `10 10`.
(This was the spec's one open question; five captured frames settle it.)
"""
if len(params) != 10:
raise ValueError(f"params must be exactly 10 bytes, got {len(params)}")
if not 0 <= offset <= 0xFFFF:
raise ValueError(f"offset must fit in uint16, got {offset:#x}")
if not 0 <= sub <= 0xFF:
raise ValueError(f"sub must be a single byte, got {sub:#x}")
payload = (bytes([MM_CMD, 0x00, sub, 0x00, (offset >> 8) & 0xFF, offset & 0xFF])
+ params + bytes(data))
body = payload + bytes([checksum(payload)])
return bytes([ACK, STX]) + stuff(body) + bytes([ETX])
def request_sub(frame: bytes) -> int:
"""The SUB of a built host->unit frame (`41 02 <stuffed body> 03`).
Used by the protocol's send-side opcode gate, which must see exactly what is
about to go on the wire rather than trust the caller's word for it.
"""
if len(frame) < 5 or frame[0] != ACK or frame[1] != STX or frame[-1] != ETX:
raise ValueError(f"not a host->unit request frame: {bytes(frame[:8]).hex()}")
body = unstuff(frame[2:-1])
if len(body) < 17 or body[0] != MM_CMD:
raise ValueError(f"not a host->unit request frame: {bytes(frame[:8]).hex()}")
# Canonical form only: what this check reads must be exactly what the unit
# parses. An unescaped 02/03/04, a `10 XX` outside {02,03,04,10} or a
# trailing lone DLE would be read one way here and another by the unit.
if stuff(body) != frame[2:-1]:
raise ValueError(
f"not a canonical request frame (stuffing differs): {bytes(frame[:8]).hex()}")
return body[2]
# ── Response frame ────────────────────────────────────────────────────────────
@dataclass
class MicromateFrame:
"""A parsed, de-stuffed unit→host response frame."""
sub: int # response SUB; the request was 0xFF − this
flags: int # payload[1] — 0xC5 Blastware line, 0x03 Thor line
page_hi: int
page_lo: int
data: bytes # payload[5:], checksum stripped
checksum_valid: bool
chk_byte: int = 0 # the checksum byte as received
@property
def request_sub(self) -> int:
"""The SUB this is answering. No known exception to `0xFF − SUB`."""
return 0xFF - self.sub
@property
def page_key(self) -> int:
"""payload[3:5] as a uint16 BE — a page/address on `0x5A` responses."""
return (self.page_hi << 8) | self.page_lo
@property
def firmware_line(self) -> str:
return {FLAGS_BLASTWARE: "blastware", FLAGS_THOR: "thor"}.get(self.flags, "unknown")
@property
def probe_length(self) -> Optional[int]:
"""Data length declared by a **probe** response: uint16 BE at data[3:5].
⚠ Only meaningful in the reply to an `offset = 0` probe. Series III
hardcodes a `DATA_LENGTHS` table; a Micromate will tell you instead,
which already caught one divergence (call-home config is `0x7E`, where
Series III has `0x7C`).
⚠ It is a **uint16 BE**, not a byte. Read as `data[3]` alone it is
right only while the high byte is zero, and wrong by 47x for
`SUB 0x1A`: a true `0x082C` (2092) reads as 44.
Returns None on a frame too short to hold the field. Note this reads
as 0 on the single-step reads Thor actually uses — those are not probes,
and `page_key` is the meaningful field there.
"""
if len(self.data) < 5:
return None
return (self.data[3] << 8) | self.data[4]
# ── Streaming parser ──────────────────────────────────────────────────────────
class MicromateFrameParser:
"""Incremental parser for unit→host frames. Mirrors `S3FrameParser`.
Feed bytes with `feed()`; completed frames are returned and also collected
in `.frames`.
IDLE — scanning for a bare STX
IN_FRAME — collecting; bare ETX terminates
AFTER_DLE — the next byte is literal, whatever it is
Request frames are rejected rather than parsed: a frame whose `payload[0]`
is not `0x00` is dropped, so feeding a bidirectional capture yields only
the responses.
"""
_IDLE, _IN_FRAME, _AFTER_DLE = 0, 1, 2
def __init__(self) -> None:
self._state = self._IDLE
self._body = bytearray()
self.frames: list[MicromateFrame] = []
# Distinguishes "no bytes at all" from "bytes but no complete frame" on
# a timeout. That distinction earned its keep during the Series III
# work and costs one integer here.
self.bytes_fed: int = 0
def reset(self) -> None:
self._state = self._IDLE
self._body.clear()
self.bytes_fed = 0
def feed(self, data: bytes) -> list[MicromateFrame]:
self.bytes_fed += len(data)
completed: list[MicromateFrame] = []
for b in data:
frame = self._step(b)
if frame is not None:
completed.append(frame)
self.frames.append(frame)
return completed
def _step(self, b: int) -> Optional[MicromateFrame]:
if self._state == self._IDLE:
if b == STX:
self._body.clear()
self._state = self._IN_FRAME
# Boot strings, modem RING/CONNECT chatter and stray ACKs land here
# and are discarded.
elif self._state == self._IN_FRAME:
if b == DLE:
self._state = self._AFTER_DLE
elif b == ETX:
self._state = self._IDLE
return self._finalise()
else:
self._body.append(b)
elif self._state == self._AFTER_DLE:
# Uniform rule: the escaped byte is itself, including 0x03.
self._body.append(b)
self._state = self._IN_FRAME
return None
def _finalise(self) -> Optional[MicromateFrame]:
body = bytes(self._body)
if len(body) < _MIN_PAYLOAD + 1:
return None
payload, chk_received = body[:-1], body[-1]
if payload[0] != MM_RSP_CMD:
return None # a request frame, or garbage that framed by accident
return MicromateFrame(
sub = payload[2],
flags = payload[1],
page_hi = payload[3],
page_lo = payload[4],
data = payload[5:],
checksum_valid = (chk_received == checksum(payload)),
chk_byte = chk_received,
)
-330
View File
@@ -1,330 +0,0 @@
"""
micromate/idf_ascii_report.py — parse Thor (Micromate Series IV) IDF ASCII reports.
Thor exports a `.IDFW.txt` or `.IDFH.txt` sidecar next to each `.IDFW`
(waveform) or `.IDFH` (histogram) event binary. Each sidecar is a
plain-text file with `"Key : Value"` lines covering the full device-
authoritative event metadata — PPV per channel, ZC Freq, Time of Peak,
Peak Acceleration / Displacement, sensor self-check results, project
strings, calibration date, battery level, etc. — followed by a raw
waveform-samples block headed by the literal line "Waveform Data Channels".
This is the Thor analogue of `minimateplus/bw_ascii_report.py` for the
Blastware (Series III) report format. The parser is intentionally
permissive: we extract everything we recognise into a flat dict and
silently ignore anything we don't. Downstream callers parse units
(`"0.2119 in/s"` → 0.2119) only on the fields they need.
Example input (truncated):
"EventType : Full Waveform"
"SampleRate : 1024 sps"
"EventTime : 16:27:23"
"EventDate : 2023-12-19"
"TranPPV : 0.0251 in/s"
"VertPPV : 0.2119 in/s"
"LongPPV : 0.0282 in/s"
"PeakVectorSum : 0.2131 in/s"
"MicPSPL : 99.4 dB(L)"
"TranZCFreq : 6.5 Hz"
"SerialNumber : UM11719"
"Version : Micromate ISEE 11.0AK"
"FileName : UM11719_20231219162723.IDFW"
"BatteryLevel : 3.8 volts"
"Calibration : November 22, 2023 by Instantel"
"TranTestResults : Passed"
"TitleString1 : UPMC Presby-Loc 3-Level1-1R Elevator Rm"
Waveform Data Channels
Tran Vert Long MicL
0.0003 -0.0003 0.0003 0.00013
...
"""
from __future__ import annotations
import datetime
import re
from typing import Any, Dict, Optional, Tuple, Union
# Lines look like: "Key : Value" (quotes literal, single ":" separator)
_LINE_RE = re.compile(r'^\s*"?([^":]+?)"?\s*:\s*"?(.*?)"?\s*$')
# Marker that ends the metadata block — everything after is raw sample data.
_WAVEFORM_BLOCK_MARKER = "waveform data channels"
def _normalize_key(raw: str) -> str:
"""Convert "TranPPV" / "PreTriggerLength" → snake_case."""
s = raw.strip()
# Insert underscore between lower→upper / digit→letter transitions
s = re.sub(r"(?<=[a-z0-9])(?=[A-Z])", "_", s)
s = re.sub(r"(?<=[A-Z])(?=[A-Z][a-z])", "_", s)
s = s.replace("-", "_").replace(" ", "_")
return s.lower()
def _strip_unit_suffix(value: str) -> str:
"""Return the numeric part of values like "0.2119 in/s" → "0.2119".
Also strips Thor's below/above-threshold prefixes:
"<0.005 in/s" → "0.005" (below-noise-floor reading)
">100 Hz" → "100" (above-measurement-range reading)
"""
parts = value.strip().split()
token = parts[0] if parts else value.strip()
if token.startswith("<") or token.startswith(">"):
token = token[1:]
return token
def _parse_float(value: str) -> Optional[float]:
try:
return float(_strip_unit_suffix(value))
except (ValueError, TypeError):
return None
def _parse_int(value: str) -> Optional[int]:
try:
return int(float(_strip_unit_suffix(value)))
except (ValueError, TypeError):
return None
def parse_idf_report(text: Union[str, bytes]) -> Dict[str, Any]:
"""
Parse a Thor IDFW.txt / IDFH.txt sidecar.
Returns a flat dict with two kinds of entries:
- **Raw fields** — every `Key : Value` line, keyed by snake_case
of the original key, value as a string (unit suffix preserved).
Lets callers grab any field we haven't explicitly normalised.
- **Derived fields** — a curated set with parsed types:
* `serial_number` str
* `event_type` str ("Full Waveform" / "Full Histogram")
* `event_datetime` ISO-8601 string ("YYYY-MM-DDTHH:MM:SS") when
both EventDate and EventTime are present
* `sample_rate` int (samples/sec)
* `tran_ppv`,`vert_ppv`,`long_ppv` float (in/s)
* `mic_ppv` float (dB or psi — same units as MicPSPL)
* `peak_vector_sum` float (in/s)
* `tran_zc_freq`,`vert_zc_freq`,`long_zc_freq` float (Hz)
* `record_time_sec` float (seconds)
* `pre_trigger_sec` float (seconds)
* `project` str (from TitleString1 — Thor's location)
* `client` str (TitleString2)
* `operator` str (TitleString3 — company/operator)
* `notes` str (TitleString4)
* `setup` str
* `version` str (firmware)
* `battery_volts` float
* `calibration_text` str (e.g. "November 22, 2023 by Instantel")
* `tran_test_passed`, `vert_test_passed`, `long_test_passed`,
`mic_test_passed` bool ("Passed" → True; anything else → False)
* `filename` str (FileName line — useful sanity check)
Stops parsing at the literal "Waveform Data Channels" line; the
raw-samples block is left to whoever wants to decode the binary.
Input may be `str` or `bytes` (`utf-8`/`latin-1` tolerant).
"""
if isinstance(text, bytes):
try:
text = text.decode("utf-8")
except UnicodeDecodeError:
text = text.decode("latin-1", errors="replace")
raw: Dict[str, str] = {}
for line in text.splitlines():
stripped = line.strip()
if not stripped:
continue
if stripped.lower().startswith(_WAVEFORM_BLOCK_MARKER):
break
m = _LINE_RE.match(stripped)
if not m:
continue
key = _normalize_key(m.group(1))
value = m.group(2).strip()
# Multi-value lines (Channel, Units, etc.) — coalesce by appending.
if key in raw:
raw[key] = raw[key] + "; " + value
else:
raw[key] = value
out: Dict[str, Any] = dict(raw) # keep all raw fields
# ── Derived fields ───────────────────────────────────────────────────────
def _take(*candidates: str) -> Optional[str]:
for c in candidates:
if c in raw:
return raw[c]
return None
# Event identity
if "serial_number" in raw:
out["serial_number"] = raw["serial_number"]
if "event_type" in raw:
out["event_type"] = raw["event_type"]
if "file_name" in raw:
out["filename"] = raw["file_name"]
# Combined date+time. Waveform sidecars use "EventDate" / "EventTime";
# histogram sidecars use "HistogramStartDate" / "HistogramStartTime".
# Prefer the event_* names when both are present.
ed = raw.get("event_date") or raw.get("histogram_start_date")
et = raw.get("event_time") or raw.get("histogram_start_time")
if ed and et:
try:
dt = datetime.datetime.strptime(f"{ed} {et}", "%Y-%m-%d %H:%M:%S")
out["event_datetime"] = dt.isoformat()
except ValueError:
pass
# Numeric scalars. For every field we typify here, we MUST drop the
# raw string copy from `out` when parsing fails — Thor writes things
# like "<0.005 in/s" (below threshold) and "N/A" (not measured) that
# would otherwise linger in `out` as strings, sneak into SQLite REAL
# columns via permissive type affinity, and then crash the JS
# frontend on `.toFixed(...)`.
int_fields = ("sample_rate",)
for key in int_fields:
v = raw.get(key)
if v is None:
continue
iv = _parse_int(v)
if iv is not None:
out[key] = iv
else:
out.pop(key, None)
float_fields = (
"tran_ppv", "vert_ppv", "long_ppv", "peak_vector_sum",
"tran_zc_freq", "vert_zc_freq", "long_zc_freq",
"tran_peak_acceleration", "vert_peak_acceleration",
"long_peak_acceleration",
"tran_peak_displacement", "vert_peak_displacement",
"long_peak_displacement",
"mic_zc_freq",
)
for key in float_fields:
v = raw.get(key)
if v is None:
continue
fv = _parse_float(v)
if fv is not None:
out[key] = fv
else:
out.pop(key, None)
# Time-of-peak: Thor labels these "TimeofPeak" (lowercase "of") so the
# normalizer produces "*_timeof_peak". Map them to the canonical
# ``*_time_of_peak`` output keys for downstream consumers.
for raw_key, out_key in (
("tran_timeof_peak", "tran_time_of_peak"),
("vert_timeof_peak", "vert_time_of_peak"),
("long_timeof_peak", "long_time_of_peak"),
("mic_timeof_peak", "mic_time_of_peak"),
):
v = raw.get(raw_key)
if v is None:
continue
fv = _parse_float(v)
if fv is not None:
out[out_key] = fv
# Microphone — Thor reports MicPSPL (dB(L)) which is the closest
# analogue to BW's mic_ppv. The raw "99.4 dB(L)" string stays in
# `out` under the original `mic_pspl` key for display; the parsed
# float goes in `mic_ppv`.
mic = raw.get("mic_pspl")
if mic is not None:
fv = _parse_float(mic)
if fv is not None:
out["mic_ppv"] = fv
# Record / pre-trigger duration — same drop-on-failure discipline.
rt = raw.get("record_time")
if rt is not None:
fv = _parse_float(rt)
if fv is not None:
out["record_time_sec"] = fv
pt = raw.get("pre_trigger_length")
if pt is not None:
fv = _parse_float(pt)
if fv is not None:
out["pre_trigger_sec"] = fv
# Project / client / operator / location strings. Thor's title
# strings are operator-defined; conventional mapping (per Thor's
# default TitleNote labels in the example data):
# TitleString1 = Location → project (sensor location identifier)
# TitleString2 = Client → client
# TitleString3 = Company → operator (the monitoring company)
# TitleString4 = Notes → notes
out["project"] = _take("title_string1")
out["client"] = _take("title_string2")
out["operator"] = _take("title_string3", "operator")
out["notes"] = _take("title_string4", "post_event_note")
if "setup" in raw:
out["setup"] = raw["setup"]
if "version" in raw:
out["version"] = raw["version"]
# Battery (e.g. "3.8 volts" → 3.8)
bl = raw.get("battery_level")
if bl is not None:
fv = _parse_float(bl)
if fv is not None:
out["battery_volts"] = fv
# Calibration line is free-form (e.g. "November 22, 2023 by Instantel").
if "calibration" in raw:
out["calibration_text"] = raw["calibration"]
# Sensor self-check results — bool flags
for key, out_key in (
("tran_test_results", "tran_test_passed"),
("vert_test_results", "vert_test_passed"),
("long_test_results", "long_test_passed"),
("mic_test_results", "mic_test_passed"),
):
v = raw.get(key)
if v is not None:
out[out_key] = v.strip().lower() == "passed"
return out
def serial_from_filename(name: str) -> Optional[str]:
"""Convenience: pull the serial prefix from a Thor event filename.
Thor uses the literal serial as the filename prefix:
UM11719_20231219163444.IDFW → "UM11719"
BE9439_20200713124251.IDFH → "BE9439"
"""
m = re.match(r"^([A-Z]{2}\d+)_\d{14}\.(IDFH|IDFW)(?:\.txt)?$",
name, re.IGNORECASE)
return m.group(1).upper() if m else None
def parse_event_filename(name: str) -> Optional[Tuple[str, datetime.datetime, str]]:
"""Parse `<SERIAL>_<YYYYMMDDHHMMSS>.<KIND>` → (serial, datetime, kind).
`kind` is "IDFH" or "IDFW" (upper-case). Returns None on no match.
"""
m = re.match(r"^([A-Z]{2}\d+)_(\d{14})\.(IDFH|IDFW)$",
name, re.IGNORECASE)
if not m:
return None
try:
ts = datetime.datetime.strptime(m.group(2), "%Y%m%d%H%M%S")
except ValueError:
return None
return m.group(1).upper(), ts, m.group(3).upper()
-723
View File
@@ -1,723 +0,0 @@
"""
micromate/idf_file.py — Thor IDF binary codec.
Decodes the Instantel Micromate Series IV ``.IDFW`` (waveform) and
``.IDFH`` (histogram) binary on-disk format. Sister module to
``minimateplus/event_file_io.py``.
Status (2026-05-28):
- **Genuine Series IV / Thor binaries** are all signed
``00 12 01 00 00 00 Instantel\\0`` (sig-A in earlier notes). Two
Series III (Blastware) binaries appear in the example corpus
(``BE9439_*``) — they share the ``.IDFW``/``.IDFH`` extension by
filing convention but carry a BW STRT header (``10 00 01 80 00 00
Instantel STRT...``) and are NOT Thor data. The reader detects
them by signature and raises NotImplementedError pointing callers
at ``minimateplus.event_file_io.read_blastware_file()``.
- **IDFW waveform body** reuses the BW segment-rotated block codec
verbatim. Body always starts at file offset ``0x0f1f``. Samples
decoded via ``minimateplus.waveform_codec.decode_waveform_v2``
with 87–99% byte-exact match against ``.IDFW.txt`` sidecar (quiet
events). Loud events hit the BW codec's known walker-stops-early
limit. Residual ~3% drift on per-sample deltas — likely a
Thor-specific 12-bit delta refinement that BW's codec doesn't
model. Geo LSB = 0.0003 in/s; mic factor ~2.14e-6 psi/count.
- **IDFH histogram body**: 12-byte segment header
``[len_be 2B] 0a 00 00 00 [00 NN_counter] 05 3f`` introduces a
segment of ``N`` 72-byte interval records (``N = (len - 10) // 72``).
Each record holds 4 × 16-byte per-channel min/max/halfp + 8-byte
tail. Geo peaks via ``max(|min|, |max|) / 32768 × 10`` in/s
(matches sidecar within ~1.8%), freq via ``512 / halfp`` Hz.
**All 859 Thor IDFH files in the corpus decode (181,071 intervals).**
- Binary metadata directly extracted: serial, timestamp, sample_rate,
record_time, calibration_date. Other fields fall back to the paired
``.IDFW.txt`` / ``.IDFH.txt`` sidecar (consumed by
``WaveformStore.save_imported_idf``).
The full reverse-engineering writeup lives in
``docs/idf_protocol_reference.md``.
"""
from __future__ import annotations
import datetime
import struct
from dataclasses import dataclass
from pathlib import Path
from typing import Optional, Union
# Thor IDFW bodies use the series-3 record-chain decoder.
#
# This was previously pinned to the SUPERSEDED tag-dispatch walker
# (`decode_waveform_legacy`) on the stated grounds that "Thor has no ASCII
# ground truth in the corpus and its geo scaling is separately suspect".
# Both premises were false: Thor writes a per-sample CSV export next to every
# binary (see scratch/verify_thor_against_csv.py), and the scaling is now
# resolved (see _GEO_LSB_IPS). Measured against that ground truth on
# 2026-09-10, the record chain beats the legacy walker outright:
#
# channel truncation 55/153 files -> 3/153
# files exact 98/153 -> 150/153
# per-sample exact 99.781% -> 99.854%
#
# The legacy walker stops at the first unrecognised tag and returns whatever
# channels it had, so its failure mode is silent short channels rather than an
# error. Do not re-pin it.
from minimateplus.waveform_codec import _MODES, decode_waveform_v2, is_record
from .models import IdfEvent, IdfPeaks, IdfReport
# Genuine Series IV / Thor IDF binary signature: 6 bytes, then ASCII "Instantel".
_THOR_PREFIX = b"\x00\x12\x01\x00\x00\x00"
# Stray Series III (Blastware) binaries that occasionally turn up in Thor
# corpus directories renamed to the .IDFW/.IDFH convention. Their header
# (`10 00 01 80 00 00 Instantel STRT ...`) is byte-for-byte a BW SUB 5A
# STRT record, not a Thor binary. Detected so we can refuse-and-route
# rather than mis-parse.
_BW_STRAY_PREFIX = b"\x10\x00\x01\x80\x00\x00"
_INSTANTEL_TAG = b"Instantel"
# Most common body offset for sig-A IDFW files (~50% of prod events;
# 151/154 in the original tests/fixtures/THORDATA_example corpus). The
# body is the segment-rotated block stream consumed by decode_waveform_v2;
# bytes [0:3] are the magic ``00 02 00`` preamble. Production events
# routinely use other offsets — see :func:`_find_waveform_body_offset`
# for the dynamic scan. This constant survives only as the priority hint.
_BODY_START_SIG_A = 0x0F1F
# Magic bytes that mark a candidate waveform-body preamble.
_BODY_MAGIC = b"\x00\x02\x00"
# Where to start looking for body candidates inside the file. Skip the
# fixed-header region where the same magic legitimately appears inside
# channel-test records and the compliance block (offsets 0x015d, 0x091c,
# 0x0ae2, 0x0d30 in observed events).
# Lowered from 0x0E00 to 0x0C00 (2026-09-10). Three-channel events -- mic
# disabled -- have a shorter fixed header and put their record chain head at
# 0x0dba, below the old floor. The head was therefore invisible to the scan,
# which fell through to the *Vert* segment-0 record and decoded a body shifted
# one position around the channel rotation. 46 of 139 files in the
# 9-10-26-csv-req corpus were affected; all 46 became per-sample exact once
# the head was reachable. The floor still skips the fixed-header region,
# where `is_record()` can match channel-test records (0x015d, 0x091c, 0x0ae2).
_BODY_SCAN_FLOOR = 0x0C00
# Cap on trial decodes per file. Chain-head detection normally yields one
# or two candidates; the cap only bounds the worst case on a corrupt file.
_MAX_BODY_CANDIDATES = 16
# Geophone count → in/s.
#
# The old value 0.0003 was read off the smallest non-zero sample in the
# sidecar corpus, but that sample is Thor's *4-decimal display rounding* of
# the true LSB, not the LSB itself. It read every series-4 geophone sample
# 3.3% low. The quantisation ladder gives it away: counts 1..6 export as
# 0.0003, 0.0006, 0.0009, 0.0012, 0.0016, 0.0019 — an LSB of exactly 0.0003
# would end 0.0015, 0.0018.
#
# The value below maximises exact 4-dp agreement over 1,046,016 paired
# samples (454 channel-events, 2 units) at 99.854%, versus 50.7% for 0.0003.
# It is a global constant, not a per-unit calibration: all 8 UM units in the
# production store independently agree to within ±0.07% on their
# device-reported PPV. 1/LSB = 3222.6 counts per in/s.
#
# The value is pinned, not guessed. Each exported sample constrains the LSB
# to the window that rounds to the printed 4-dp figure; intersecting 991,415
# such constraints (clean channel-events only) gives
#
# LSB in [0.000310307933, 0.000310308057] width 1.2e-10
#
# 0.000310308 sits at the centre of that window. Equivalent full scale is
# 10.0 in/s / 0.000310308 = 32226.05 counts.
#
# Corroboration from the device: an IDFH interval that never recorded keeps
# its min/max accumulator at its ±full-scale seed, and that seed is
# (min=+32226, max=-32226) — the same magnitude, independently. Note the
# tempting closed form 10.0/32226 is very slightly WRONG: it lands 4.5e-10
# above the feasible window and loses 78 boundary samples to the literal
# value while never winning one. Series-3 uses 32000 counts for the same
# 10.0 in/s, so the two generations do NOT share a scale.
#
# Ground truth + harness: scratch/verify_thor_against_csv.py
_GEO_LSB_IPS = 0.000310308
# Microphone count → psi, derived from sidecar regression on 50 sample
# pairs from UM11719_20231219162723.IDFW (mic-heavy event).
_MIC_LSB_PSI = 2.14e-6
# IDFH histogram constants.
# Bytes per interval record = 16 per channel + an 8-byte tail, so a
# 4-channel unit uses 72 and a mic-disabled 3-channel unit uses 56. It is
# NOT a constant: derive it per segment from the interval counter (see
# decode_idfh_body). This value survives only as the 4-channel default.
_IDFH_INTERVAL_SIZE = 72 # bytes per per-interval record (4 channels)
_IDFH_CHANNEL_BLOCK = 16 # bytes per channel inside an interval record
_IDFH_INTERVAL_TAIL = 8 # bytes after the per-channel blocks
_IDFH_SEGMENT_HEADER = 10 # bytes: [len_be 2B][0a 00 00 00 4B][00 NN 2B][05 3f 2B]
_IDFH_SEGMENT_TAIL = 2 # bytes after the interval data block, before next marker
_IDFH_HALFP_FREQ_NUM = 512.0 # freq_hz = NUM / halfp; halfp ≤ 5 means ">100 Hz" sentinel
_IDFH_CHANNELS = ("Tran", "Vert", "Long", "MicL")
# ─── Binary metadata extraction ─────────────────────────────────────────────
@dataclass
class IdfBinaryMetadata:
"""Fields recoverable from the sig-A binary header (no .txt needed)."""
serial: Optional[str] = None
event_datetime: Optional[datetime.datetime] = None
sample_rate: Optional[int] = None
record_time_sec: Optional[float] = None
calibration_date: Optional[datetime.date] = None
def _read_ascii_z(buf: bytes, off: int, maxlen: int = 64) -> Optional[str]:
if off >= len(buf):
return None
end = buf.find(b"\x00", off, off + maxlen)
if end < 0:
end = min(off + maxlen, len(buf))
s = buf[off:end].decode("ascii", errors="replace").strip()
return s or None
def _decode_8byte_timestamp(buf: bytes, off: int) -> Optional[datetime.datetime]:
"""Layout: ``[day][month][year_hi][year_lo][unknown][hour][min][sec]``."""
if off + 8 > len(buf):
return None
day, mon, yh, yl, _unk, hr, mn, sc = buf[off : off + 8]
year = (yh << 8) | yl
if not (2015 <= year <= 2050 and 1 <= mon <= 12 and 1 <= day <= 31
and 0 <= hr < 24 and 0 <= mn < 60 and 0 <= sc < 60):
return None
try:
return datetime.datetime(year, mon, day, hr, mn, sc)
except ValueError:
return None
def extract_binary_metadata(buf: bytes) -> IdfBinaryMetadata:
"""Pull serial/timestamp/sample_rate/record_time/calibration from the
sig-A binary header.
Field positions confirmed against UM11719_20231219162723.IDFW; stable
across the 151-file sig-A corpus.
"""
md = IdfBinaryMetadata()
# Serial: null-terminated ASCII at 0x14E.
md.serial = _read_ascii_z(buf, 0x14E, maxlen=16)
# Sample rate + record time live in a BW-compatible compliance block.
# Locate the 6-byte anchor `be 80 00 00 00 00` and read offsets relative
# to it: anchor-6 = sample_rate uint16 BE; anchor+6 = record_time float32 BE.
anchor = buf.find(b"\xbe\x80\x00\x00\x00\x00", 0x800, 0xA00)
if anchor > 0:
sr_bytes = buf[anchor - 6 : anchor - 4]
if len(sr_bytes) == 2:
sr = int.from_bytes(sr_bytes, "big")
if sr in (256, 512, 1024, 2048, 4096):
md.sample_rate = sr
rt_bytes = buf[anchor + 6 : anchor + 10]
if len(rt_bytes) == 4:
try:
rt = struct.unpack(">f", rt_bytes)[0]
if 0.1 <= rt <= 600.0:
md.record_time_sec = float(rt)
except struct.error:
pass
# Event timestamp: 8 bytes. Position differs between IDFW (0x97A) and
# IDFH (0x9F8); scan a small range and accept the first valid decode.
for off in (0x97A, 0x9F8):
ts = _decode_8byte_timestamp(buf, off)
if ts is not None:
md.event_datetime = ts
break
# Calibration date: day, month, year_be at 0x194-0x197.
if len(buf) > 0x197:
day, mon = buf[0x194], buf[0x195]
year = int.from_bytes(buf[0x196 : 0x198], "big")
if 1 <= mon <= 12 and 1 <= day <= 31 and 2015 <= year <= 2050:
try:
md.calibration_date = datetime.date(year, mon, day)
except ValueError:
pass
return md
# ─── Sample decoder + unit conversion ───────────────────────────────────────
def _find_waveform_body_offset(buf: bytes) -> Optional[int]:
"""Pick the file offset of the waveform body by trial-decoding every
``00 02 00`` magic position past the fixed-header region.
The body's location isn't fixed across all sig-A IDFW files — about
half the production events use ``0x0f1f``, but the rest have offsets
that shift based on header padding / channel-config layout. We
auto-detect by:
1. Find every ``00 02 00`` occurrence past ``_BODY_SCAN_FLOOR``.
2. Try ``decode_waveform_v2()`` on each candidate.
3. Pick the offset whose decoded sample count is largest.
Returns the offset, or ``None`` if no candidate yielded more than
the trivial 2-sample preamble (= "no real body found").
Costs ~2-8 trial decodes per file; in practice the first candidate
past 0x0e00 is usually the right one.
"""
if len(buf) < _BODY_SCAN_FLOOR + 8:
return None
# 1. Locate every plausible per-channel record header. A header carries
# [len 2B][channel_id][00][00] at +2..+6, so anchor the search on the
# three-byte ``<cid> 00 00`` signature and validate with is_record().
# Scanning candidate *preambles* instead is not viable: MODE_RAW16 is
# ``00 00``, so every run of three zero bytes would look like a body
# start and each would cost a full trial decode (~0.5 s/file measured).
floor = max(0, _BODY_SCAN_FLOOR - 7)
starts: list = []
for cid in (0x46, 0x47, 0x48, 0x49):
sig = bytes((cid, 0x00, 0x00))
i = floor
while True:
j = buf.find(sig, i)
if j < 0:
break
i = j + 1
q = j - 4
if q >= floor and is_record(buf, q):
starts.append(q)
if not starts:
return None
starts.sort()
# 2. A body begins at the head of a record chain -- a record that no other
# record's length field points at. The head's own payload is the
# implicit segment-0 Tran record, and the body offset is head + 7 (past
# [len 2B][cid][00][00][seg]) so that body[1:3] lands on the mode.
ends = {q + 2 + int.from_bytes(buf[q + 2 : q + 4], "big") for q in starts}
heads = [q for q in starts if q not in ends] or starts[:1]
# 3. Trial-decode each head and keep the best. Prefer a candidate where
# all four channels come out the same length: scoring on raw sample
# count alone picks false positives sitting *inside* a record header,
# which decode a plausible-looking but rotation-shifted body that
# silently drops each channel's segment 0.
best = None
best_off = None
for head in heads[:_MAX_BODY_CANDIDATES]:
j = head + 7
if j + 3 > len(buf) or (buf[j + 1], buf[j + 2]) not in _MODES:
continue
try:
decoded = decode_waveform_v2(buf[j:])
except Exception:
continue
if not decoded:
continue
lengths = [len(v) for v in decoded.values() if v]
total = sum(len(v) for v in decoded.values())
# A "real" body has more than just the 2-sample preamble.
if total <= 2:
continue
# >= 3 rather than == 4: a mic-disabled event has only the three geo
# channels, and demanding four made `equal` permanently False for
# them, leaving the pick to raw sample count alone.
equal = len(lengths) >= 3 and len(set(lengths)) == 1
score = (equal, total)
if best is None or score > best:
best, best_off = score, j
return best_off
def _decode_waveform_samples(buf: bytes) -> Optional[dict]:
"""Decode samples from the sig-A waveform body.
Returns the raw decoder counts dict — geo LSB = 0.0003 in/s, mic in
its own count unit (see :func:`mic_count_to_psi`). Returns None if
no usable body is found.
Uses :func:`_find_waveform_body_offset` to locate the body — the
file-offset varies across events (~50% sit at the canonical
``0x0f1f`` but the rest don't), so the previous hardcoded constant
silently produced 2-sample preamble-only output for half the corpus.
"""
off = _find_waveform_body_offset(buf)
if off is None:
return None
return decode_waveform_v2(buf[off:])
def geo_count_to_ips(count: int) -> float:
"""Convert a Thor geo decoder count to in/s. LSB = 0.0003 in/s."""
return count * _GEO_LSB_IPS
def mic_count_to_psi(count: int) -> float:
"""Convert a Thor mic decoder count to psi. Scale derived from
regression over 50 sample pairs in UM11719_20231219162723.IDFW;
consistent to ~5%. Calibration constants from the channel block
can refine this once decoded.
"""
return count * _MIC_LSB_PSI
# ─── IDFH histogram decoder ─────────────────────────────────────────────────
@dataclass
class IdfhInterval:
"""One decoded histogram interval (typically one minute of monitoring)."""
offset: int # file byte offset of the 72-byte record
# Per-channel min/max ADC counts (int16 BE), half-period samples, peak count.
# Peak = max(|min|, |max|). freq_hz = 512/halfp (None if halfp ≤ 5 →
# ">100 Hz" sentinel; matches sidecar convention).
tran_min: int
tran_max: int
tran_halfp: int
vert_min: int
vert_max: int
vert_halfp: int
long_min: int
long_max: int
long_halfp: int
micl_min: int
micl_max: int
micl_halfp: int
# 4 on a normal unit; 3 when the microphone is disabled, in which case the
# micl_* fields are absent from the record and read as zero.
n_channels: int = 4
def has_channel(self, channel: str) -> bool:
return channel != "MicL" or self.n_channels >= 4
def peak_count(self, channel: str) -> int:
mn = getattr(self, f"{channel.lower()}_min")
mx = getattr(self, f"{channel.lower()}_max")
return max(abs(mn), abs(mx))
def peak_ips(self, channel: str) -> float:
"""Convert peak count to in/s (geo channels only)."""
# Same geo LSB as the waveform path — verified independently against
# the IDFH exports: as peak magnitude rises (and 4-dp quantisation
# noise falls) the implied LSB converges on 0.0003103, matching
# _GEO_LSB_IPS. The old 10.0/32768 read histogram peaks 1.7% low.
return self.peak_count(channel) * _GEO_LSB_IPS
def freq_hz(self, channel: str) -> Optional[float]:
halfp = getattr(self, f"{channel.lower()}_halfp")
if halfp <= 5:
return None
return _IDFH_HALFP_FREQ_NUM / halfp
def _is_unwritten_interval(interval: "IdfhInterval") -> bool:
"""True for an interval slot the device reserved but never wrote.
Thor seeds each interval's per-channel accumulators at ``min = +full
scale`` and ``max = -full scale`` and then narrows them as samples
arrive. A slot that never recorded keeps that seed, so ``min > max`` —
impossible for real data. Such a record decodes to a full-scale
10.0 in/s peak on every channel and, being a max-over-intervals, poisons
the whole file's PPV.
Rare but real: exactly 1 of 497,611 corpus intervals, and it inflated
that file's Long PPV from 0.0081 to 10.0 in/s. The inversion is always
all-or-nothing across channels (0 partial cases in the corpus), so
requiring every channel to be inverted keeps this from ever firing on
genuine data.
"""
pairs = [
(interval.tran_min, interval.tran_max),
(interval.vert_min, interval.vert_max),
(interval.long_min, interval.long_max),
]
if interval.has_channel("MicL"):
pairs.append((interval.micl_min, interval.micl_max))
return all(mn > mx for mn, mx in pairs)
def _decode_idfh_interval(buf72: bytes, offset: int,
n_channels: int = 4) -> IdfhInterval:
"""Decode one interval record into per-channel min/max/halfp.
The record is ``n_channels`` × 16-byte blocks plus an 8-byte tail, so it
is 72 bytes on a normal unit and 56 when the microphone is disabled.
Missing channels read as zero.
"""
import struct
fields = []
for i in range(4):
if i >= n_channels:
fields.extend([0, 0, 0])
continue
block = buf72[i * 16 : (i + 1) * 16]
mn = struct.unpack_from(">h", block, 0)[0]
mx = struct.unpack_from(">h", block, 2)[0]
# block[4:6] = int16 BE, role unknown (possibly time-of-peak)
halfp = struct.unpack_from(">H", block, 6)[0]
# block[10:12] and block[14:16] are uint16 BE with unknown semantics
# (likely sum / count contributions for the PVS computation).
fields.extend([mn, mx, halfp])
# Tail 8 bytes (buf72[64:72]) carry PVS-related data; not yet decoded.
return IdfhInterval(
offset=offset,
tran_min=fields[0], tran_max=fields[1], tran_halfp=fields[2],
vert_min=fields[3], vert_max=fields[4], vert_halfp=fields[5],
long_min=fields[6], long_max=fields[7], long_halfp=fields[8],
micl_min=fields[9], micl_max=fields[10], micl_halfp=fields[11],
n_channels=n_channels,
)
def decode_idfh_body(buf: bytes) -> list:
"""Walk an IDFH file and decode every interval record.
The body has one or more segments; each segment header is 12 bytes:
``[length_be 2B][0a 00 00 00][counter_be 2B][05 3f]`` where ``length``
is bytes from the magic through the end of the interval block
(= 10 + 72 × n_intervals). Segments are separated by a 2-byte tail
+ next-segment 2-byte prefix (the bytes before the next length field).
``counter`` is a **uint16 BE cumulative interval index** — the 0-based
index of the LAST interval in this segment. Segments carry 10
intervals each, so it runs 9, 19, 29, ... across the file.
⚠ This validator used to require ``buf[j + 4] == 0x00``, i.e. that the
counter's high byte was zero. That silently capped every histogram at
**250 intervals**: the moment the cumulative counter passed 255 the high
byte went non-zero and every later segment was rejected, so any
monitoring run longer than ~4 hours lost its tail — frequently the part
holding the event peak, which is why those files' PPV read low. 540 of
858 corpus files were affected. Do not reinstate that check.
"""
intervals: list = []
i = 0
prev_counter = -1 # so the first segment's n = counter + 1
while True:
j = buf.find(b"\x0a\x00\x00\x00", i)
if j < 0 or j < 2:
break
# Validate: [length_be][0a 00 00 00][counter_be][05 3f]. The counter
# is deliberately NOT constrained — see the note above.
if buf[j + 6 : j + 8] != b"\x05\x3f":
i = j + 1
continue
length = int.from_bytes(buf[j - 2 : j], "big")
counter = int.from_bytes(buf[j + 4 : j + 6], "big")
header_start = j - 2
if length < _IDFH_SEGMENT_HEADER or header_start + length > len(buf):
# Truncated / bogus length — not a real segment header.
i = j + 1
continue
# The counter is the cumulative index of this segment's LAST interval,
# so the interval count is its delta from the previous segment. That
# gives the record stride, which is NOT fixed: 16 bytes per channel
# plus an 8-byte tail, so 72 for a 4-channel unit and 56 for a
# mic-disabled 3-channel one. Assuming 72 unconditionally made every
# 3-channel histogram read 7 intervals per 10-interval segment,
# walking off alignment into garbage that decoded as ~10 in/s peaks.
n = counter - prev_counter
if n <= 0:
i = j + 1
continue
stride = (length - _IDFH_SEGMENT_HEADER) // n
n_channels, remainder = divmod(stride - _IDFH_INTERVAL_TAIL,
_IDFH_CHANNEL_BLOCK)
if remainder or not (1 <= n_channels <= 4):
i = j + 1
continue
interval_start = header_start + _IDFH_SEGMENT_HEADER
for k in range(n):
off = interval_start + k * stride
if off + stride > len(buf):
break
chunk = buf[off : off + stride]
interval = _decode_idfh_interval(chunk, off, n_channels)
if _is_unwritten_interval(interval):
# Reserved-but-never-recorded slot: the min/max accumulators
# still hold their ±full-scale seed. Counting it would
# fabricate a 10.0 in/s peak on every channel.
continue
intervals.append(interval)
prev_counter = counter
# Advance past this segment + the 2-byte tail.
i = header_start + length + _IDFH_SEGMENT_TAIL
return intervals
# ─── Top-level reader ───────────────────────────────────────────────────────
@dataclass
class IdfReadResult:
"""Return type for :func:`read_idf_file`.
For waveforms (``.IDFW``), ``samples`` holds the per-channel sample
arrays in Thor decoder counts. For histograms (``.IDFH``),
``samples`` is empty and ``intervals`` holds the per-interval
record list (peaks, freqs).
"""
event: IdfEvent
samples: dict # {"Tran": [...], ...} for IDFW; empty for IDFH
binary_metadata: IdfBinaryMetadata
signature: str # always "thor" for now (sig-A genuine Thor)
intervals: Optional[list] = None # list[IdfhInterval] for IDFH; None for IDFW
def read_idf_file(
path: Union[str, Path],
*,
data: Optional[bytes] = None,
) -> IdfReadResult:
"""Parse a Thor ``.IDFW`` binary into an ``IdfEvent`` + decoded samples.
Currently implements signature-A waveforms only. Signature-B
(old-firmware) and ``.IDFH`` histograms raise NotImplementedError;
use the paired ``.IDFW.txt`` / ``.IDFH.txt`` sidecar for those via
``parse_idf_report()``.
Returns an :class:`IdfReadResult`. The caller converts int sample
counts to physical units via :func:`geo_count_to_ips` /
:func:`mic_count_to_psi`.
``path`` is used for filename in error messages and ``.IDFH`` vs
``.IDFW`` suffix detection. When ``data`` is supplied the disk
read is skipped — useful for ingest paths that already have the
bytes in memory and where the file may not exist on disk yet.
"""
p = Path(path)
buf = data if data is not None else p.read_bytes()
if len(buf) < 16 or buf[6:16] != _INSTANTEL_TAG + b"\x00":
raise ValueError(f"{p.name}: not an IDF file (missing Instantel magic)")
sig_prefix = buf[:6]
if sig_prefix == _THOR_PREFIX:
signature = "thor"
elif sig_prefix == _BW_STRAY_PREFIX:
raise NotImplementedError(
f"{p.name}: file has a Series III (Blastware) STRT header in "
"an IDF-named container — not a Thor binary. Route through "
"minimateplus.event_file_io.read_blastware_file() instead "
"(peaks decode; samples & full metadata don't, but it's not "
"Thor data so the Thor codec doesn't apply)."
)
else:
raise ValueError(f"{p.name}: unknown IDF signature {sig_prefix.hex()}")
is_histogram = p.suffix.upper() == ".IDFH"
md = extract_binary_metadata(buf)
if is_histogram:
intervals = decode_idfh_body(buf)
if not intervals:
raise ValueError(f"{p.name}: IDFH body decoded no intervals")
# Peaks: max across all intervals on each channel (per-channel max
# of stored max-magnitudes; sidecar's PPV row carries the same).
peak_tran = max((iv.peak_ips("Tran") for iv in intervals), default=0.0)
peak_vert = max((iv.peak_ips("Vert") for iv in intervals), default=0.0)
peak_long = max((iv.peak_ips("Long") for iv in intervals), default=0.0)
# Mic peak in psi — Thor stores per-interval mic ADC counts in the
# binary; convert the max count to psi via the per-count factor.
# Skip on a mic-disabled (3-channel) unit: those records carry no mic
# block at all, so peak_count("MicL") would report a synthetic zero.
mic_peak_count = max(
(iv.peak_count("MicL") for iv in intervals if iv.has_channel("MicL")),
default=0,
)
mic_peak_psi = mic_count_to_psi(mic_peak_count) if mic_peak_count else None
rep = IdfReport(
serial_number=md.serial,
event_type="Full Histogram",
event_datetime=md.event_datetime,
filename=p.name,
sample_rate=md.sample_rate,
record_time_sec=md.record_time_sec,
)
peaks = IdfPeaks(
transverse_ips=peak_tran,
vertical_ips=peak_vert,
longitudinal_ips=peak_long,
peak_vector_sum_ips=None,
mic_pspl_dbl=None, # IDFH binary doesn't carry the dB(L) value
mic_pspl_psi=mic_peak_psi,
)
event = IdfEvent(
serial=md.serial or "UNKNOWN",
timestamp=md.event_datetime or datetime.datetime(1970, 1, 1),
kind="Histogram",
filename=p.name,
sample_rate=md.sample_rate,
record_time_sec=md.record_time_sec,
peaks=peaks,
report=rep,
)
return IdfReadResult(
event=event,
samples={},
binary_metadata=md,
signature=signature,
intervals=intervals,
)
# Waveform path.
decoded = _decode_waveform_samples(buf)
if decoded is None:
raise ValueError(f"{p.name}: waveform body codec failed")
rep = IdfReport(
serial_number=md.serial,
event_type="Full Waveform",
event_datetime=md.event_datetime,
filename=p.name,
sample_rate=md.sample_rate,
record_time_sec=md.record_time_sec,
)
def _peak_ips(ch: str) -> float:
arr = decoded.get(ch, [])
return geo_count_to_ips(max((abs(v) for v in arr), default=0))
# Mic peak psi from binary: max absolute MicL ADC count × 2.14e-6 psi/count.
mic_arr = decoded.get("MicL", [])
mic_peak_count = max((abs(v) for v in mic_arr), default=0)
mic_peak_psi = mic_count_to_psi(mic_peak_count) if mic_peak_count else None
peaks = IdfPeaks(
transverse_ips=_peak_ips("Tran"),
vertical_ips=_peak_ips("Vert"),
longitudinal_ips=_peak_ips("Long"),
# PVS requires aligned per-sample √(T²+V²+L²); leave None — the
# sidecar carries it and the bridge picks it up if present.
peak_vector_sum_ips=None,
mic_pspl_dbl=None, # binary IDFW doesn't carry the dB(L) value;
# sidecar .txt fills it via IdfReport.from_dict
mic_pspl_psi=mic_peak_psi,
)
event = IdfEvent(
serial=md.serial or "UNKNOWN",
timestamp=md.event_datetime or datetime.datetime(1970, 1, 1),
kind="Waveform",
filename=p.name,
sample_rate=md.sample_rate,
record_time_sec=md.record_time_sec,
peaks=peaks,
report=rep,
)
return IdfReadResult(
event=event,
samples=decoded,
binary_metadata=md,
signature=signature,
)
-323
View File
@@ -1,323 +0,0 @@
"""
micromate/idf_to_bw_report.py — adapter that projects a parsed Thor IDF
report (+ binary metadata + decoded IDFH intervals) into the
``bw_report``-shaped dict that :mod:`sfm.report_pdf.gather_report_data`
consumes.
Lets Thor events flow through the existing Series III Event Report PDF
pipeline without duplicating the renderer. Thor's report content is
~95% the same data shape as BW's; the field names differ but the
underlying metrics map 1:1.
Caveats
───────
- **Mic units** — Thor records ``MicPSPL`` natively in dB(L). This
adapter sets ``bw_report.mic.pspl_dbl`` directly; the report
renderer recomputes the equivalent psi via its dBL→psi formula.
- **Saturation / above-range flags** — Thor doesn't always mark
``OORANGE`` the way BW does; we set ``zc_freq_above_range`` only
when a `>100` sentinel was preserved in the raw text.
- **Per-interval data** — for IDFH events we build ``interval_times``
by stepping ``IntervalSize`` from ``HistogramStartTime``; the binary
decoder confirms one record per step (882 / 881 / 881 ... across
the corpus).
- **calibration_by parsing** — Thor's free-form ``Calibration : November
22, 2023 by Instantel`` is split on ``" by "`` to extract the
calibrator; the date prefix is parsed where possible, otherwise
the binary-extracted ``calibration_date`` from
:class:`micromate.idf_file.IdfBinaryMetadata` wins.
"""
from __future__ import annotations
import datetime
import re
from typing import Any, Dict, List, Optional
# ─── Helpers ────────────────────────────────────────────────────────────────
_NUM_RE = re.compile(r"-?\d+(?:\.\d+)?")
def _parse_first_number(s: Optional[str]) -> Optional[float]:
"""Pull the first numeric token from a string like ``"0.1500 in/s"``."""
if s is None:
return None
m = _NUM_RE.search(str(s))
if not m:
return None
try:
return float(m.group(0))
except ValueError:
return None
def _parse_interval_size_s(s: Optional[str]) -> Optional[float]:
"""``"60 sec"`` → 60.0, ``"5 min"`` → 300.0, ``"1 hour"`` → 3600."""
if s is None:
return None
num = _parse_first_number(s)
if num is None:
return None
sl = str(s).lower()
if "hour" in sl or "hr" in sl:
return num * 3600.0
if "min" in sl:
return num * 60.0
return num # default to seconds
def _parse_calibration(text: Optional[str]) -> tuple[Optional[str], Optional[str]]:
"""Split ``"November 22, 2023 by Instantel"`` → (ISO date, calibrator).
Returns ``(None, None)`` if neither half parses.
"""
if not text:
return None, None
parts = str(text).split(" by ", 1)
date_part = parts[0].strip() if parts else None
by_part = parts[1].strip() if len(parts) > 1 else None
iso_date: Optional[str] = None
if date_part:
for fmt in ("%B %d, %Y", "%b %d, %Y", "%Y-%m-%d", "%m/%d/%Y"):
try:
iso_date = datetime.datetime.strptime(date_part, fmt).date().isoformat()
break
except ValueError:
continue
return iso_date, by_part
def _channel_peaks(idf: Dict[str, Any], ch_lc: str) -> Dict[str, Any]:
"""Map ``tran_ppv`` / ``tran_zc_freq`` / ... → bw_report.peaks.tran shape."""
out: Dict[str, Any] = {}
for src, dst in (
(f"{ch_lc}_ppv", "ppv_ips"),
(f"{ch_lc}_zc_freq", "zc_freq_hz"),
(f"{ch_lc}_time_of_peak", "time_of_peak_s"),
(f"{ch_lc}_peak_acceleration", "peak_accel_g"),
(f"{ch_lc}_peak_displacement", "peak_disp_in"),
):
v = idf.get(src)
if v is not None:
out[dst] = v
# ZC freq ">100" sentinel: the raw text carries it under the un-typed
# key (e.g. ``raw["tran_zc_freq"]`` would be ``">100"``), and our parser
# dropped the typed entry. Detect that case and flag.
raw_zc = idf.get(f"{ch_lc}_zc_freq")
if isinstance(raw_zc, str) and ">" in raw_zc:
out["zc_freq_above_range"] = True
out.pop("zc_freq_hz", None)
return out
def _sensor_check(idf: Dict[str, Any], ch_lc: str) -> Dict[str, Any]:
out: Dict[str, Any] = {}
fr = idf.get(f"{ch_lc}_test_freq")
if fr is not None:
out["freq_hz"] = _parse_first_number(fr)
rt = idf.get(f"{ch_lc}_test_ratio")
if rt is not None:
out["ratio"] = _parse_first_number(rt)
am = idf.get(f"{ch_lc}_test_amplitude")
if am is not None:
out["amplitude_mv"] = _parse_first_number(am)
res = idf.get(f"{ch_lc}_test_results")
if res is not None:
out["result"] = str(res).strip()
return {k: v for k, v in out.items() if v is not None}
def _interval_times(idf: Dict[str, Any], n_intervals: Optional[int]) -> List[str]:
"""Synthesise per-interval timestamps from start + interval_size × k.
Returns ``[]`` when start time or interval size is unknown.
"""
if not n_intervals:
return []
start_date = idf.get("histogram_start_date") or idf.get("event_date")
start_time = idf.get("histogram_start_time") or idf.get("event_time")
iv_str = idf.get("interval_size")
iv_s = _parse_interval_size_s(iv_str)
if not (start_date and start_time and iv_s):
return []
try:
t0 = datetime.datetime.strptime(f"{start_date} {start_time}", "%Y-%m-%d %H:%M:%S")
except ValueError:
return []
out = []
for k in range(int(n_intervals)):
t = t0 + datetime.timedelta(seconds=iv_s * (k + 1))
out.append(t.isoformat())
return out
# ─── Top-level adapter ──────────────────────────────────────────────────────
def build_bw_report_from_idf(
idf_report: Dict[str, Any],
*,
binary_md=None,
intervals: Optional[list] = None,
is_histogram: Optional[bool] = None,
) -> Dict[str, Any]:
"""Project a parsed IDF report dict (and optional binary metadata +
decoded IDFH intervals) into the BW report sidecar shape.
The returned dict is structurally identical to what
``minimateplus.event_file_io._bw_report_to_dict`` produces from a
real BW ASCII report — it can be assigned to
``sidecar["bw_report"]`` and consumed verbatim by
``sfm.report_pdf.gather_report_data``.
``intervals`` is the list of :class:`micromate.idf_file.IdfhInterval`
objects from :func:`micromate.idf_file.decode_idfh_body`; only used
for histogram events to derive accurate ``interval_times``.
"""
if is_histogram is None:
et = str(idf_report.get("event_type", ""))
is_histogram = et.lower().startswith("full histogram")
# ── Trigger / recording / device ─────────────────────────────────────
trigger_channel = idf_report.get("trigger")
trigger_level = _parse_first_number(idf_report.get("geo_trigger_level"))
geo_range_ips = _parse_first_number(idf_report.get("geo_range"))
cal_iso, cal_by = _parse_calibration(idf_report.get("calibration"))
# Prefer the binary-extracted calibration_date when our text parse fell
# through; the binary date is unambiguous.
if cal_iso is None and binary_md is not None and binary_md.calibration_date:
cal_iso = binary_md.calibration_date.isoformat()
# ── Histogram fields ────────────────────────────────────────────────
hist_block: Dict[str, Any] = {
"start": None, "stop": None, "n_intervals": None,
"interval_size": None, "interval_size_s": None,
"channel_peak_when": {},
}
if is_histogram:
sd = idf_report.get("histogram_start_date")
st = idf_report.get("histogram_start_time")
if sd and st:
try:
hist_block["start"] = datetime.datetime.strptime(
f"{sd} {st}", "%Y-%m-%d %H:%M:%S"
).isoformat()
except ValueError:
pass
ed = idf_report.get("histogram_stop_date")
et_ = idf_report.get("histogram_stop_time")
if ed and et_:
try:
hist_block["stop"] = datetime.datetime.strptime(
f"{ed} {et_}", "%Y-%m-%d %H:%M:%S"
).isoformat()
except ValueError:
pass
n_raw = idf_report.get("number_of_intervals")
if n_raw is not None:
try:
# Thor reports a float like "81.04"; round to int (the BW
# report uses an int for the column).
hist_block["n_intervals"] = int(float(str(n_raw)))
except ValueError:
pass
# When the binary decoder gave us the actual interval count, prefer it.
if intervals is not None:
hist_block["n_intervals"] = len(intervals)
hist_block["interval_size"] = idf_report.get("interval_size")
hist_block["interval_size_s"] = _parse_interval_size_s(idf_report.get("interval_size"))
# interval_times derived from start+step (the BW report uses the
# exact strings; we match its representation).
times = _interval_times(idf_report, hist_block["n_intervals"])
# Per-channel peak when (absolute date+time at which the channel's
# peak occurred over the histogram run). Thor splits this into
# ``TranPeakDate`` / ``TranPeakTime`` etc.
peak_when: Dict[str, str] = {}
for ch_label, ch_lc in (("Tran", "tran"), ("Vert", "vert"), ("Long", "long"), ("MicL", "mic")):
d = idf_report.get(f"{ch_lc}_peak_date")
t = idf_report.get(f"{ch_lc}_peak_time")
if d and t:
try:
peak_when[ch_label] = datetime.datetime.strptime(
f"{d} {t}", "%Y-%m-%d %H:%M:%S"
).isoformat()
except ValueError:
continue
if peak_when:
hist_block["channel_peak_when"] = peak_when
# ── Mic block ────────────────────────────────────────────────────────
mic_block = {
"weighting": "L", # Thor mic is ISEE Linear
"pspl_dbl": idf_report.get("mic_ppv"), # the dB(L) float
"pspl_saturated": False,
"zc_freq_hz": idf_report.get("mic_zc_freq"),
"zc_freq_above_range": isinstance(idf_report.get("mic_zc_freq"), str)
and ">" in str(idf_report.get("mic_zc_freq")),
"time_of_peak_s": idf_report.get("mic_time_of_peak"),
}
if mic_block["zc_freq_above_range"]:
mic_block["zc_freq_hz"] = None
# ── Peaks ────────────────────────────────────────────────────────────
vs_block = {
"ips": idf_report.get("peak_vector_sum"),
"time_s": _parse_first_number(idf_report.get("peak_vector_sum_time_sum")),
"when": None,
"saturated": False,
}
if is_histogram:
# PVS absolute date+time, when present.
vs_d = idf_report.get("peak_vector_sum_date")
vs_t = idf_report.get("peak_vector_sum_time")
if vs_d and vs_t:
try:
vs_block["when"] = datetime.datetime.strptime(
f"{vs_d} {vs_t}", "%Y-%m-%d %H:%M:%S"
).isoformat()
except ValueError:
pass
return {
"available": True,
"event_type": idf_report.get("event_type"),
"version": idf_report.get("version"),
"trigger": {
"channel": trigger_channel,
"geo_level_ips": trigger_level,
},
"recording": {
"sample_rate_sps": idf_report.get("sample_rate"),
"record_time_s": idf_report.get("record_time_sec"),
"pretrig_s": idf_report.get("pre_trigger_sec"),
"stop_mode": idf_report.get("record_stop_mode"),
"geo_range_ips": geo_range_ips,
"units": idf_report.get("units"),
},
"device": {
"battery_volts": idf_report.get("battery_volts"),
"calibration_date": cal_iso,
"calibration_by": cal_by,
},
"peaks": {
"tran": _channel_peaks(idf_report, "tran"),
"vert": _channel_peaks(idf_report, "vert"),
"long": _channel_peaks(idf_report, "long"),
"vector_sum": vs_block,
},
"mic": mic_block,
"sensor_check": {
"tran": _sensor_check(idf_report, "tran"),
"vert": _sensor_check(idf_report, "vert"),
"long": _sensor_check(idf_report, "long"),
"mic": _sensor_check(idf_report, "mic"),
},
"histogram": hist_block,
"monitor_log": [],
"pc_sw_version": None,
}
Loaded 100 of 583 files, more files were not shown because too many files have changed in this diff. Show more