4 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 287ef2a653 docs(changelog): Unreleased -- one MicL count is 0.25 Pa
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-10-31 02:19:49 -04:00
serversdownandClaude Opus 5.5 30a249ef57 merge: one MicL count is 0.25 Pa; Blastware's dB offset 81.9384
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-10-31 02:19:17 -04:00
serversdownandClaude Opus 5.5 18951505f0 fix(decode): Blastware's mic dB offset is 81.9384, a hair above exact 0.25 Pa
The checker caught 280 regressions in the first mic fix: every one a dB
value at count 129, where 20 log10(129 x 0.25 Pa / 20 uPa) = 124.149997
rounds to 124.1 and Blastware prints 124.2.  Blastware's dB offset sits in
[81.9383, 81.9385] -- any value there matches its dB(L) on 1,729,252 /
1,729,253 DL2 intervals (the last printed '0.000'); exact 81.93820 rounds
count 129 down, and the old 81.94 misses counts 119 and 132.  Single
precision does not explain it.  psi keeps 0.25 Pa per count, which
matches every interval.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-10-31 01:55:45 -04:00
serversdownandClaude Opus 5.5 5644dbd5ad fix(decode): one MicL count is 0.25 Pa -- the mic psi was ~95x low
SFM converted mic counts to psi with a '~0.5 psi full-scale' guess
(0.0125 / 32768 psi per count).  Measured against 1,729,253 DL2
histogram intervals' 'MicL Peak' columns: one count is exactly 0.25 Pa.
count x 0.25 Pa matches Blastware's psi(L) on every interval, and
20 log10(count x 0.25 Pa / 20 uPa) its dB(L) on all but 17 exact
half-way cases.

- event_file_io: _MIC_FS_PSI -> _MIC_PSI_PER_COUNT = 0.25 / 6894.757
  (3.626e-5 psi per count, was 3.81e-7).  The event's mic peak in psi,
  and with it the .h5 mic trace (event_hdf5 back-solves its scale from
  that peak), come right on events with no report.
- waveform_codec.mic_count_to_db: the offset is 20 log10(0.25 / 20e-6)
  = 81.938, not 81.94 -- the old value missed 49 of those intervals at a
  rounding edge (count 119 printed 123.4, 81.94 gave 123.451).

The decoded count was always right: count 16 on K441LTON.900 is
Blastware's 106.0 dB.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-10-31 01:28:23 -04:00
6 changed files with 94 additions and 18 deletions

No files matched your search

+31
View File
@@ -7,6 +7,37 @@ All notable changes to seismo-relay are documented here.
## Unreleased
### Fixed
- **The mic in psi was ~95× low: one MicL count is 0.25 Pa.**
- SFM converted mic counts with a "~0.5 psi full-scale" guess (0.0125 /
32768 psi per count). The decoded count was always right: count 16 on
`K441LTON.900` is Blastware's 106.0 dB.
- Measured against 1,729,253 DL2 histogram intervals' "MicL Peak"
columns: count × 0.25 Pa matches Blastware's psi(L) on every one.
- `event_file_io._MIC_FS_PSI` is now `_MIC_PSI_PER_COUNT` = 0.25 / 6894.757
(3.626e-5 psi per count).
- The event's mic peak comes right on events with no report, and so does
the `.h5` mic trace (`event_hdf5` derives its scale from that peak).
- **dB offset:** `waveform_codec.mic_count_to_db` now uses 81.9384, not
81.94. Blastware's dB sits in a measured window, [81.9383, 81.9385], a
hair above the exact 81.93820. Any value in the window matches on
1,729,252 / 1,729,253 intervals.
- The checker's first run of this fix flagged 280 regressions, every one
count 129, which exact 0.25 Pa rounds to 124.1 against Blastware's
124.2.
- The old 81.94 misses counts 119 and 132.
- Decode checker, against the pre-fix baseline: 45,035 fixed, 0
regressions.
| Field | Mismatches before | After |
|---|---|---|
| interval psi | 42,783 | 26 |
| interval dB | 974 | 20 |
| mic peak | 345 | 40 |
| waveform mic samples | 1,056 | 37 |
- ⚠ **Codec change, covered by the same release bump.** The backfill
rewrites stored mic values on report-less events; report-paired events
keep the report's. No schema change.
- **A histogram's peak vector sum is now the one the unit stores.** SFM
computed it from each channel's interval peak, and those can come from
different moments. So on 86% of DL2's histograms with no report it read
+3 -3
View File
@@ -18,7 +18,7 @@ from dataclasses import dataclass
from typing import Callable, Optional, Sequence
from .bw_xml_report import XmlReport
from .event_file_io import _GEO_INT16_FS, _GEO_NORMAL_FS_INS, _MIC_FS_PSI, decode_blastware_bytes
from .event_file_io import _GEO_INT16_FS, _GEO_NORMAL_FS_INS, _MIC_PSI_PER_COUNT, decode_blastware_bytes
from .models import Event
from .waveform_codec import mic_count_to_db
@@ -133,7 +133,7 @@ def _mic_converter(ref: XmlReport) -> Optional[Callable[[int], float]]:
if "dB(L)" in units:
return mic_count_to_db
if "psi(L)" in units:
return lambda c: c * _MIC_FS_PSI
return lambda c: c * _MIC_PSI_PER_COUNT
return None
@@ -200,7 +200,7 @@ def _interval_converter(title: str) -> Optional[Callable[[int], float]]:
if ch == "MicL" and rest == "Peak dB(L)":
return mic_count_to_db
if ch == "MicL" and rest == "Peak psi(L)":
return lambda c: c * _MIC_FS_PSI
return lambda c: c * _MIC_PSI_PER_COUNT
return None
+8 -6
View File
@@ -708,10 +708,12 @@ _GEO_INT16_FS = 32000.0
# the Normal range (the same assumption as the samples above).
_HIST_GEO_UNIT_INS = 16 * _GEO_NORMAL_FS_INS / _GEO_INT16_FS
# Microphone scale factor, psi per ADC count. Approximate — exact factor
# depends on the geophone-vs-mic ADC scaling and the firmware reference.
# We mark mic_psi as "computed approximate" in the sidecar.
_MIC_FS_PSI = 0.0125 / _INT16_FS # ~0.5 psi full-scale assumption
# Microphone scale factor, psi per MicL count: one count is 0.25 Pa
# (waveform_codec.MIC_PA_PER_COUNT, measured against Blastware's psi(L) on
# 1,729,253 DL2 intervals). It replaces a "~0.5 psi full-scale" guess,
# 0.0125 / 32768, that read every mic peak ~95x low (2026-10-31).
_PA_PER_PSI = 6894.757
_MIC_PSI_PER_COUNT = _wc.MIC_PA_PER_COUNT / _PA_PER_PSI
def _decode_strt(strt: bytes) -> dict:
@@ -763,9 +765,9 @@ def _peaks_from_samples(samples: dict[str, list[int]]) -> PeakValues:
vert = _peak_ins(samples.get("Vert", []))
long_ = _peak_ins(samples.get("Long", []))
# Mic in psi (approximate)
# Mic in psi: one count = 0.25 Pa
mic_ch = samples.get("MicL", []) or []
mic = max((abs(int(v)) for v in mic_ch), default=0) * _MIC_FS_PSI
mic = max((abs(int(v)) for v in mic_ch), default=0) * _MIC_PSI_PER_COUNT
# Peak vector sum: max over time of sqrt(T^2 + V^2 + L^2)
pvs = 0.0
+20 -9
View File
@@ -628,23 +628,34 @@ def decoded_to_adc_counts(decoded: dict) -> dict:
}
# One MicL count is 0.25 Pa (measured 2026-10-31): count x 0.25 Pa matches
# Blastware's "MicL Peak psi(L)" on all 1,729,253 DL2 histogram intervals
# checked.
MIC_PA_PER_COUNT = 0.25
# Blastware's dB(L) offset sits a hair above the exact 20 log10(0.25 Pa /
# 20 uPa) = 81.93820: any value in [81.9383, 81.9385] matches its dB on
# 1,729,252 / 1,729,253 intervals (the one left printed "0.000"), while
# 81.93820 rounds count 129 (162 intervals) to 124.1 against Blastware's
# 124.2, and the 81.94 first fitted to a handful of values misses counts 119
# and 132. Its display chain presumably carries rounded constants; the
# window, not the physics, is what is measured.
_MIC_DB_REF = 81.9384
def mic_count_to_db(count: int) -> float:
"""Convert a MicL ADC count to dB(L) for BW-display-compatible output.
Empirical formula (confirmed 2026-05-11 against V70 fixture: count=813
→ 140.1 dB; count=±1 → ±81.94 dB; count=±24 → ±109.5 dB):
dB = sign(count) × (81.9384 + 20 × log10(|count|)) for |count| ≥ 1
dB = 0.0 for count == 0
dB = sign(count) × (81.94 + 20 × log10(|count|)) for |count| ≥ 1
dB = 0.0 for count == 0
The constant 81.94 corresponds to 10^(81.94/20) ≈ 12490 mic ADC counts
being the dB(L) reference level — almost certainly a calibration
constant from the device's mic.
81.9384 ≈ 20 log10(0.25 Pa / 20 µPa); see _MIC_DB_REF.
count=±1 → ±81.94 dB; count=813 → 140.14 dB (the V70 fixture).
"""
if count == 0:
return 0.0
sign = 1.0 if count > 0 else -1.0
return sign * (81.94 + 20.0 * math.log10(abs(count)))
return sign * (_MIC_DB_REF + 20.0 * math.log10(abs(count)))
# ── A5-frame entry point ────────────────────────────────────────────────────
+27
View File
@@ -179,3 +179,30 @@ def test_interval_pvs_per_interval():
# Blastware's interval table, first four "Geo PVS" values
for got, want in zip(pvs[:4], (0.065, 0.034, 0.015, 0.461)):
assert abs(got * 0.005 - want) <= 0.0005 + 1e-9, (got, want)
# ── The mic: one count = 0.25 Pa ────────────────────────────────────────────
# Measured 2026-10-31 against 1,729,253 DL2 histogram intervals' "MicL Peak"
# columns: count x 0.25 Pa matches Blastware's psi(L) on every one, and
# 20 log10(count x 0.25 Pa / 20 uPa) its dB(L) on all but 17 exact half-way
# cases. The old psi factor (a "~0.5 psi full-scale" guess) was ~95x small.
from minimateplus.waveform_codec import mic_count_to_db # noqa: E402
@pytest.mark.parametrize("count,printed", [
(1, "81.94"), # XML sample cell
(119, "123.4"), # Blastware interval tables, where 81.94 + 20 log10 gave 123.451
(132, "124.3"), # ... and 124.351
(129, "124.2"), # 162 intervals; exactly 0.25 Pa gives 124.149997, a hair under half-way
(813, "140.14"), # V70 fixture, Blastware display
])
def test_mic_db_matches_blastware(count, printed):
d = len(printed.split(".")[1])
assert abs(mic_count_to_db(count) - float(printed)) <= 0.5 * 10 ** -d + 1e-9
def test_mic_peak_in_psi():
# Blastware: MicL PSPL 106.0 dB(L) = 20 uPa x 10^(106/20) = 3.990 Pa = 5.787e-4 psi.
ev = read_blastware_file(_FIX / "decode-checker-10-29-26/M529L4XQ.R30H")
assert ev.peak_values.micl == pytest.approx(5.787e-4, rel=0.01)
+5
View File
@@ -142,3 +142,8 @@ def test_pvs_carveout_needs_the_clipped_channel_at_the_ceiling():
side.values["TranPPV"] = 1.256
res = {r.field: r for r in compare(side, ref, CARVEOUTS)}
assert res["PeakVectorSum"].verdict == "mismatch"
def test_interval_mic_psi_matches():
# psi(L) report: every interval's "MicL Peak psi(L)" now converts right
assert _results("T004JTRF.ME0H")["intervals.MicL Peak psi(L)"].verdict == "match"