27 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 89433c1fdb docs(spec): every phase lands on this branch; one merge to dev at the end
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 15:35:26 -04:00
serversdownandClaude Opus 5.5 e1af35e1d0 docs(spec): park the phase 1a review's minor findings in the spec
They were recorded only in the plan's scratch ledger, which is deleted
when the plan finishes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:59:42 -04:00
serversdownandClaude Opus 5.5 278921796a fix(sfm): any request taking the legacy path is refused beside a held line
The /device guard let every non-UM serial through before its held-line
check.  FastAPI drops an undeclared `serial`, so `?serial=BE18193` on a
legacy route still ran Series-3 code at an address holding a Series-4
line -- the hole the guard exists to close.  Serial-aware routes go
straight to DeviceAccess, which refuses that case itself; everything
else is checked.  baud is no longer parsed (it is not in the address
key, and pydantic's coercion made "38400.0" a second way past).

Also, from the same review:
- RingWatchTransport clears its frame state on every write, so a stray
  STX on an idle line cannot hide the ring that answers the next request.
- Series4Session.is_open reads _client once; held_serial() calls it
  without the unit lock, and a concurrent hang-up between two reads was
  an AttributeError (a 500).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:58:57 -04:00
serversdownandClaude Opus 5.5 080e8f4704 docs: serial parameter, settings/hangup endpoints, single-worker rule, cool-down prerequisite for 1c
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:33 -04:00
serversdownandClaude Opus 5.5 d393a149f8 fix(sfm): a different UM serial at a held address is refused (409), not swapped
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:17 -04:00
serversdownandClaude Opus 5.5 aa79e996c5 fix(sfm): construct the DeviceAccess singleton at import
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:17 -04:00
serversdownandClaude Opus 5.5 52ada0215c fix(sfm): RADIO RING detection ignores bytes inside frames
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:10 -04:00
serversdownandClaude Opus 5.5 82b91835fb fix(sfm): one guard in front of every /device route -- UM serials 501 off the serial-aware routes, held lines 409 serial-less requests
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:44:35 -04:00
serversdownandClaude Sonnet 5.5 6dd34f8fd7 docs(claude): SFM speaks Series 4 by serial -- phase 1a done, bench-checked on UM20147
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:27:56 -04:00
serversdownandClaude Opus 5.5 e7a5a3cce1 feat(sfm): serial-named /device/info, /status, /settings and /hangup for both series
With serial: one contract for Series 3 and 4 through sfm.device_access.  Without it: the legacy Series-3 path, unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:26:16 -04:00
serversdownandClaude Opus 5.5 73b6089012 fix(sfm): retry once on a dropped held line; refuse Series-3 beside a held Series-4 line
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:23:57 -04:00
serversdownandClaude Opus 5.5 96c7b31f4e feat(sfm): DeviceAccess -- one door, held Series-4 lines, a reaper, and the same answer shape for both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:17:39 -04:00
serversdownandClaude Opus 5.5 ece9ec79e3 feat(sfm): Series-4 identify, status and settings into the shared models
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:15:43 -04:00
serversdownandClaude Opus 5.5 8e7333b899 feat(sfm): Series-4 session -- call up once, stay on the line, release on RADIO RING
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:13:34 -04:00
serversdownandClaude Opus 5.5 d39f8ef360 fix(sfm): Series-3 status says its serial is unverified
Series 3 status reads no serial, so the serial shown is the requested one, not one the unit reported. detail now carries serial_verified=False.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:12:17 -04:00
serversdownandClaude Opus 5.5 5c6ca049c8 feat(sfm): Series-3 adapter -- identify, status, settings into the shared models
Connect-per-request with the TCP cold-boot retry kept; a different unit answering is refused (409) whenever the serial is already in hand.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:10:23 -04:00
serversdownandClaude Haiku 5.5 bb4b26835b feat(sfm): per-unit lock -- one connection per unit, 423 when busy
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:08:10 -04:00
serversdownandClaude Haiku 5.5 034529f498 feat(sfm): device_access core -- typed errors, series by serial prefix, shared models
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:06:20 -04:00
serversdownandClaude Opus 5.5 fa032567c2 feat(micromate): get_event_count() and read_unsolicited()
0x06 content[0:4] moves from the bench tool into the client, tested against a real UM20147 read and its chain-walk count.  read_unsolicited() reads without sending, for spotting RADIO RING on an idle session.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:04:35 -04:00
serversdownandClaude Opus 5.5 31181f64e6 fix(micromate): is_open() called a property -- TypeError on every real transport
Hidden because the test double defined is_connected as a method; it is now a property, matching BaseTransport.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:02:32 -04:00
serversdownandClaude Opus 5.5 8eab5f9479 docs(plan): SFM device access phase 1a -- foundation plus identify/status/settings for both series
Ten tasks, test-first: the is_open fix, two client reads, core types, the
per-unit lock, both adapters, Series-4 sessions with ring safety,
DeviceAccess with the reaper and the contract tests, the endpoints, and a
read-only bench check on UM20147.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 19:10:15 -04:00
serversdownandClaude Opus 5.5 bbc6fe2a61 docs(spec): serial-less requests keep today's shapes; phase 1 splits into 1a/1b/1c
Nothing breaks between phases: the shared models apply when a request names
the unit by serial, and the legacy Series-3 path stays as it is until the
webapp (1c) and watch_unit.sh move over.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 19:03:03 -04:00
serversdownandClaude Opus 5.5 68cad4e2ab docs(spec): monitor logs are their own piece of work -- row 6 moves to the parking lot
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:54:24 -04:00
serversdownandClaude Opus 5.5 435c1978a0 docs(spec): park setup files and schedules as one open question
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:42:41 -04:00
serversdownandClaude Opus 5.5 90171996d6 docs(spec): say plainly what 'no PC-side setup library' means
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:38:56 -04:00
serversdownandClaude Opus 5.5 3215c17e37 docs(spec): one user experience for both series -- the guiding principle, applied
Brian's principle: talking to a Series 3 or a Series 4 unit is identical for
the user; only the serial prefix and each model's settings differ, and the
adapters absorb the rest.

Five places the draft broke it, now fixed: units are named the same way
(serial + address, no-serial kept only as a legacy Series-3 path); one set
of series-neutral response models with series-only fields under `detail`;
one opaque event_id for both; a uniform 501 "not supported for Series N
yet" instead of missing routes; and the webapp brought into scope with the
same screens for both.  Adds an adapter table, contract tests that keep the
two adapters honest, and notes that existing Series-3 response shapes move
to the shared models (the webapp updates with them; Terra-View does not
call /device/*).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:33:48 -04:00
serversdownandClaude Opus 5.5 1c6aa04687 docs(spec): SFM Series-4 parity and a device safety layer -- design for review
Parity of jobs with Series 3 for regular comms and settings (identify,
status, settings, events, download, monitor log, start/stop, call-home
enable/disable, setup push); Series-4 emergency tools deferred.  A single
device-access layer: series from the serial prefix, identity confirmed
before any write, a per-unit lock, an 0xA2 opcode guard, read-back
verification of every change, distinct error codes, and an audit table.
Series-4 sessions ("stay on the line") now; Series-3 sessions after a bench
test of MiniMate hangup/DCD behaviour.

Includes the fix list found in the 2026-10-19 inventory, the to-be-added
table, and the RX55 container idea as a parking-lot item.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 17:41:00 -04:00
22 changed files with 4925 additions and 11 deletions

No files matched your search

+15 -2
View File
@@ -97,8 +97,13 @@ Read this first when picking the project back up.
— `micromate/setup_block.py`, measured fields only, checksum-verified, — `micromate/setup_block.py`, measured fields only, checksum-verified,
69 tests on 15 real fixtures (`tests/fixtures/micromate-setup/`, force- 69 tests on 15 real fixtures (`tests/fixtures/micromate-setup/`, force-
added). `bridges/mm_client_check.py` prints it; Brian matched every line added). `bridges/mm_client_check.py` prints it; Brian matched every line
against UM20147's screen. Not yet in SFM — nothing there uses the against UM20147's screen.
Micromate client. ✅ **SFM speaks Series 4 by serial (phase 1a, 2026-10-20):** `/device/info`,
`/device/monitor/status` and `/device/settings` take `serial` and return one
shared shape for both series through `sfm/device_access/`. Micromate lines
are held open (one call-up, keep-alive 60 s, idle hang-up 5 min, released on
RADIO RING); MiniMates still reconnect per request. Without `serial` the
legacy Series-3 path is unchanged. Next: 1b (events), 1c (webapp).
- **🔑 ACH / call-home, captured end to end (2026-10-14).** A Micromate signals - **🔑 ACH / call-home, captured end to end (2026-10-14).** A Micromate signals
`RADIO RING`; **two paths exist and timing decides which**: if anything `RADIO RING`; **two paths exist and timing decides which**: if anything
already holds the modem's single TCP session the ring rides that connection, already holds the modem's single TCP session the ring rides that connection,
@@ -1405,8 +1410,16 @@ GET /device/event?host=1.2.3.4&tcp_port=9034&index=0
GET /device/monitor/status?host=1.2.3.4&tcp_port=9034 ← battery, memory, mode GET /device/monitor/status?host=1.2.3.4&tcp_port=9034 ← battery, memory, mode
POST /device/monitor/start?host=1.2.3.4&tcp_port=9034 ← start recording POST /device/monitor/start?host=1.2.3.4&tcp_port=9034 ← start recording
POST /device/monitor/stop?host=1.2.3.4&tcp_port=9034 ← stop recording POST /device/monitor/stop?host=1.2.3.4&tcp_port=9034 ← stop recording
GET /device/settings?serial=UM20147&host=1.2.3.4&tcp_port=9034 ← shared-model settings, either series
POST /device/hangup?host=1.2.3.4&tcp_port=9034 ← release a held Series-4 line
``` ```
`serial=` (UM = Series 4, BE/BA = Series 3) on `/device/info`, `/connect`,
`/monitor/status`, `/settings` returns the shared model, uncached. A `UM` serial on any
other `/device/*` route is 501; any request taking the legacy Series-3 path at a held
Series-4 address is 409.
SFM must run a single uvicorn worker (locks and held lines are per process).
Server retries once on `ProtocolError` for TCP connections (handles cold-boot timing). Server retries once on `ProtocolError` for TCP connections (handles cold-boot timing).
### DB read endpoints (query seismo_relay.db written by ach_server.py) ### DB read endpoints (query seismo_relay.db written by ach_server.py)
+13
View File
@@ -177,10 +177,23 @@ via a thread-safe `_LiveCache` (plain Python dict + `threading.Lock`):
| `POST` | `/device/monitor/start` | Sends SUB 0x96; immediately evicts status cache | | `POST` | `/device/monitor/start` | Sends SUB 0x96; immediately evicts status cache |
| `POST` | `/device/monitor/stop` | Sends SUB 0x97; immediately evicts status cache | | `POST` | `/device/monitor/stop` | Sends SUB 0x97; immediately evicts status cache |
| `POST` | `/device/call_home` | Reads, patches specified fields, writes back to device | | `POST` | `/device/call_home` | Reads, patches specified fields, writes back to device |
| `GET` | `/device/settings` | Recording settings in the shared model, either series; serial required; never cached |
| `POST` | `/device/hangup` | Releases a held Series-4 line now; `{"hung_up": bool}` |
**Cache bypass** — All cached endpoints accept `?force=true` to skip the cache and **Cache bypass** — All cached endpoints accept `?force=true` to skip the cache and
force a fresh read from the device. force a fresh read from the device.
**Serial-named requests (Series 3 and 4)** — `/device/info`, `/device/connect`,
`/device/monitor/status` and `/device/settings` accept `serial` (`UM...` = Series 4
Micromate, `BE...`/`BA...` = Series 3 MiniMate Plus) and return one shared model
for either series. Serial-named requests are **not cached** and ignore `force`.
Without `serial` the legacy Series-3 behaviour is unchanged. Any other `/device/*`
route given a `UM` serial answers **501** ("not supported for Series 4 yet"), and any
request that takes the legacy Series-3 path (no `serial`, or a `BE`/`BA` serial on a
route that does not take one) at an address holding a Series-4 line answers **409**
(use `POST /device/hangup` first). Series-4 lines are held open between requests, so
SFM must run a **single uvicorn worker**: locks and held lines are per process.
**Cache stats** — `GET /cache/stats` returns hit/miss counts and TTL info; `DELETE /cache/device` **Cache stats** — `GET /cache/stats` returns hit/miss counts and TTL info; `DELETE /cache/device`
clears the device cache immediately. clears the device cache immediately.
File diff suppressed because it is too large. Load diff
@@ -0,0 +1,479 @@
# SFM: Series-4 parity and a device safety layer — design
**Date:** 2026-10-20 · **Branch:** `feat/series4-sfm-parity` · **Status:** draft for review
**Decided with:** Brian, in conversation 2026-10-19/20.
## In plain terms
SFM can already *read* a Micromate almost as well as it reads a MiniMate, but
only through the Python library and bench scripts. SFM's web endpoints still
only speak Series 3. This design does three things:
1. Gives Series 4 the same everyday jobs in SFM that Series 3 has: identify a
unit, check its status, read its settings, list and download events,
start/stop monitoring, and change its settings.
2. Adds a **safety layer** every device request goes through. It makes sure a
command only reaches the unit it was meant for, logs every change, and
checks every change by reading the unit back.
3. Lets SFM **stay on the line** with a Micromate. It calls up once, confirms
the serial, and keeps the connection open for later commands instead of
reconnecting each time.
**The guiding principle (Brian): talking to a Series 3 unit and talking to a
Series 4 unit is the same for the user.** It is the same screens, the same
endpoints, the same way of naming a unit, and the same shape of answer. The
only visible difference is the serial (`UM…` vs `BE…`) and the settings each
model has. The differences live underneath, in one adapter per series.
It does **not** cover the emergency tools (runaway-unit stops, rescue, erase),
the call-home receiver, or anything async. Those come later, as features
shared by both series.
**Production reach, stated honestly:** while THOR is set to stay connected to
production Micromates, a modem's single connection is taken. SFM can't reach
those units until THOR lets go or SFM takes over call-home. In this phase,
Series-4 SFM is for the bench and for units THOR is not holding.
---
## Decisions
| decision | why | who |
|---|---|---|
| **One user experience for both series** | the user's method is identical; only the serial prefix and each model's settings differ; adapters absorb the rest | Brian |
| Match **jobs**, not endpoints | some Series-3 endpoints only exist to work around Series-3 quirks | agreed |
| **No Series-4 emergency tools** yet (runaway stop, rescue, erase) | Micromates rarely need them | Brian |
| The series comes from the **serial prefix**: `UM` = Micromate, `BE` = MiniMate Plus, `BA` = Blastmate | the prefixes are definitive, so there is no probing | Brian |
| Before any **write**, confirm the unit that answered is the one named | SFM addresses units by IP; a moved modem or stale IP means a different unit answers | agreed |
| **Synchronous** endpoints for now; async later, for both series together | parity first, then shared features | agreed |
| **No library of setup files on the PC** (unlike THOR). The unit's own settings are the truth: SFM reads them from the unit, and verifies every push by reading the unit back | THOR keeps one copy of each setup on the PC and another on the unit, linked only by file name. Nothing checks the contents match, so the PC's `test2` and the unit's `test2` can say different things | Brian |
| **Sessions for Series 4 now; Series 3 only after a bench test** | THOR holds Micromate lines daily without harm; a MiniMate's hangup/DCD behaviour is untested | Brian |
| Audit log in **SFM's database** (new table) | Terra-View can show it; it fits the existing `CREATE TABLE IF NOT EXISTS` pattern | proposed |
---
## Scope: the parity table
Rows 8 and 11 of the original inventory (runaway stops, rescue/erase) are out
of scope by decision. Row 6 (monitor log) moved to the parking lot: it is its
own piece of work, together with call-in monitor-log ingest.
| # | job | Series 3 in SFM today | Series 4: protocol status | Series 4 in this phase |
|---|---|---|---|---|
| 1 | Identify a unit | `/device/info` (walks the whole chain, slow) | implemented: `connect()` | dispatch to the Micromate client |
| 2 | Quick status (monitoring, battery, memory, clock) | `monitor/status`, `storage_range`, `events/index` | implemented: `get_state()`; the `0x06` event count is decoded only in the bench tool | same endpoints; move the count decode into the client |
| 3 | Read settings | compliance in `/device/info`; `GET /device/call_home` | `get_setup()` implemented and verified on hardware; call-home: enable + dial string observed, rest unmapped | setup in full; call-home returns enable + dial string + raw |
| 4 | List events | `/device/events` (downloads every event to list them) | implemented, and cheap: the chain walk returns sizes | the same event-list shape as Series 3, each event carrying an `event_id` |
| 5 | Download an event | `/event/{i}`, `/waveform`, `/blastware_file` | implemented: streams the `.IDFW`/`.IDFH` itself, with a decode self-check | the same download and save-to-DB actions as Series 3. Underneath, Series 4 saves through `/db/import/idf_file` |
| 7 | Start / stop monitoring | `monitor/start`, `monitor/stop` | mapped, identical to Series 3 (`0x96`/`0x97`, acks `0x69`/`0x68`); never sent | **first write.** Verify with `0x49` state |
| 9 | Change call-home settings | `POST /device/call_home` | write mapped (`0x2C` → `0x7E`/`0x7F`, same as Series 3); field map mostly unknown | enable/disable only; the rest waits for the THOR round |
| 10 | Change recording settings | `POST /device/config` | sequence mapped (`0xDA` → `0x68/73` → `0x82/83` → `0x71/72`); no encoder | read-modify-write, stop → push → restart, verify with `get_setup()` |
---
## Architecture
### One door for every device request
A new module, `sfm/device_access.py`, sits between the `/device/*` handlers and
the two device libraries. No handler opens a transport or picks a library
itself any more.
```
/device/* handler
│ (serial, address, action, tier)
▼
device_access ── series from serial prefix ── session / per-unit lock
│ │ │
│ ▼ ▼
│ minimateplus (S3) or micromate (S4) audit table
▼
read-back verification (changes only)
```
- **Naming a unit is the same for both: `serial` + address.** The prefix picks
the adapter: `UM` → Series 4 (`micromate`); `BE` or `BA` → Series 3
(`minimateplus`); any other prefix → 422. A request with no `serial` is
treated as Series 3. That is a **legacy path** kept only so existing scripts
keep working; the webapp and every new caller always send `serial`.
- **One contract.** Same `/device/*` paths, same request parameters, and
**the same response models for both series**:
- `UnitInfo`, `UnitStatus`, `UnitSettings`, `EventRef`, `ChangeResult`
- Anything only one series has goes under a `detail` object inside the same
model, never as a different top-level shape. `"series": 3 | 4` is
informational.
- **Events have one identity.** An opaque `event_id` string from the event
list, passed back to download it. Underneath it is Series 3's position or
Series 4's device key, plus the serial; the user never handles either.
- **Not-yet-supported is uniform.** If one series can't do something yet,
the endpoint still exists and answers **501 "not supported for Series N
yet"**. It is never a missing route or a different call.
- **Work separate from HTTP.** Each operation is a plain function taking the
session. The handler is a thin wrapper, so making an operation an async job
later means changing the wrapper, not the operation.
### Adapters
Each series implements the same operation set behind `device_access`:
| operation | Series 3 adapter | Series 4 adapter |
|---|---|---|
| `identify` | STARTUP + serial + config | `connect()` |
| `status` | `0x1C` (+ `0x06`) | `get_state()` + `0x06` count |
| `read_settings` | `0x1A` compliance decode | `get_setup()` |
| `list_events` | today's walk | chain walk (cheap) |
| `download_event` | 5A → Blastware file | 5A → `.IDFW`/`.IDFH` |
| `start` / `stop` | `0x96` / `0x97` (exists) | `0x96` / `0x97` (new) |
| `read_call_home` / `set_call_home_enabled` | exists | `0x2C` / `0x7E`+`0x7F` |
| `push_settings` | `/device/config` path (exists) | setup push (new) |
| `call_up` / `hang_up` | connect-per-request underneath, until the bench test | held session |
Each adapter maps its native data into the shared models. `UnitSettings` keeps
the fields both series have under the same names and units: record mode,
sample rate, record time, histogram interval, trigger levels, the notes as
label → value. Model-specific fields go under `detail`.
**Requests that include `serial` get the shared models; requests without it
keep today's Series-3 shapes, unchanged.** Nothing breaks in between: the
webapp moves to `serial` in phase 1c, and the old path retires after that and
after `watch_unit.sh` moves. Terra-View does not call `/device/*`. The
emergency endpoints (`stop_monitoring_*`, `rescue`, `events/erase`) are not
touched and stay Series-3 only; a `UM` serial gets 501.
### The webapp
The same screens for both series. You name a unit by serial + address (today
it takes host/port only), and the series shows as a badge, nothing more. Read
panels for both series land in phase 1; each write button appears for Series 4
in the phase that adds that write.
### The safety layer
**Tiers.** Every operation declares one:
| tier | examples | what the layer does |
|---|---|---|
| read | info, status, setup, events, download | runs; no identity check |
| change | start/stop, call-home, setup push | identity check → audit → send → **read back** → audit the result |
| destructive | delete, erase (none in this phase) | everything above + the caller must send the unit's serial as `confirm` |
**Identity check (changes only).** Before the first change in a connection,
compare the serial the unit reports with the one requested; on a mismatch,
refuse (409) and send nothing. Series 4 already reads the serial in
`connect()`. A Series-3 change adds one serial read (`SUB 0x15`), about one
round trip.
**Opcode guard.** A send-side check that refuses known cross-series
collisions. It starts with **`0xA2`**, which is CONFIRM ERASE on Series 3 and
"end call-home" on Series 4. This phase never sends `0xA2`; the guard makes
that impossible by accident. The table of colliding opcodes lives in one
place.
**One connection per unit.** A per-unit lock keyed by address
(`tcp:host:port` / `serial:port`). A request for a busy unit waits up to
**20 s** (configurable; under Terra-View's 60 s proxy timeout), then gets
**423 "unit busy"** instead of opening a second connection. This applies to Series 3 as well. The webapp's Diagnostics
refresh currently fires three device requests at once against a modem that
allows one; under the lock they queue.
**Read-back verification.** A zero-data ack has never been proof that a write
applied. Every change is followed by a read:
- start/stop → `0x49` state: start expects `0x02`, stop expects `0x00`. Record
the value either way; `0x03` is the in-call-home state
- call-home → re-read `0x2C` and compare the edited bytes
- setup push → `get_setup()` and compare every field that was set
A mismatch is reported as a failed change (and audited as one), even if the
ack was clean.
**Errors that say what happened.** Distinct responses for:
- 503: couldn't connect
- 504: connected but the unit didn't answer
- 423: unit busy
- 409: wrong unit
- 422: bad input
- 502: the reply was malformed
Today 502 covers both of the first two.
**Audit table.** New table `device_commands`, created on startup like the
others. It is additive, but still a schema change, so the changelog says so.
One row per change attempt:
| column | content |
|---|---|
| `ts`, `serial`, `series`, `address` | who and where |
| `action`, `tier` | e.g. `monitor_stop`, `change` |
| `request` | parameters, plus hex of what was sent |
| `ack` | reply summary |
| `verified` | read-back result: `ok` / `mismatch` / `not_checked` |
| `outcome`, `error` | final result |
| `caller` | best-effort origin (`webapp`, `terra-view`, `script`) |
Reads are not audited.
### Sessions
1. **Call up.** Connect, `connect()` (POLL / SERIAL / STATE), identity check
against the requested serial.
2. **On the line.** Requests for that unit run in turn on the same connection,
behind the per-unit lock.
3. **Keep-alive.** A POLL every 60 s while idle. The ACEmanager TCP idle
timeout is 2 min.
4. **Hang up.** On `POST /device/hangup`, after 5 idle minutes, or on any
transport error. A reconnect is a new session with a new identity check.
5. **Ring safety.** If `RADIO RING` arrives on an SFM session, log it and hang
up **immediately**. Until SFM is the call-home destination, the unit's
retry should reach THOR. 🔶 *Inferred:* the unit retries; its `0x2C`
retries field reads 3.
**Call up and hang up are the same for both series.** Underneath, the
Series-3 adapter keeps today's connect-per-request behaviour until the bench
test under *Testing*; the user sees the same actions either way.
### Series-4 write path
**Encoder.** Extend `micromate/framing.py`:
- a request builder that carries a data section
- the same escape set `{02,03,04,10}`, applied to data, params and checksum
- plain SUM8 of the destuffed payload (*not* Series 3's write format)
Rules: `micromate_protocol_reference.md` → *The escape set — exactly four bytes*,
*Checksum — plain SUM8 of the de-stuffed payload*, *Write-frame destuffing*.
**Dry run.** Every Series-4 write accepts `dry_run=true`. It returns the exact
frames it would send and sends nothing. The first live send of each write is
reviewed this way first.
**Per operation:**
| operation | frames | verify | open questions it settles |
|---|---|---|---|
| start / stop | `0x96` / `0x97`, offset `0xFFFF`, zero params | `0x49` | the ack when already in that state |
| call-home enable/disable | read `0x2C` → `0x7E` (126 B content, offset `0x007E`) → `0x7F` | re-read `0x2C` | none new; bit 0 of `write[5]` |
| setup push | read `0x08`, `0x2E`, `0x1A` → `0xDA` (name) → `0x68`/`0x73` → `0x82`/`0x83` → `0x71`/`0x72` | `get_setup()` | the offset rule; whether `0x68`/`0x82` are needed |
**Setup push, details:**
- Read-modify-write of **all three** blocks, as THOR appears to do.
🔶 *Inferred from two captures:* `0x68` = the preferences content with
`[0:3]` zeroed; `0x82` = the `0x2E` content with `[0:3]` and the CRC slot
zeroed; `0x71` = the `0x1A` content `[0:2090]` with the length echo zeroed.
- Offsets come from THOR's observed constants. 🔶 The hypothesis "offset =
the read block's length + 2" fits all four, but each has been seen at one
size only.
- The edited fields come from `MicromateSetup` and are written back at the
offsets `setup_block.py` already uses. Only fields graded **measured** may
be edited.
- Sequence: stop monitoring (if running) → push → restart (if it was running)
→ verify. THOR's "must be idle" is policy, not the device, but stopping
first removes a variable from the first live write.
- ⚠ **Edit-buffer hazard.** `0x1A` reads the keypad's unsaved edits, so a
read-modify-write taken while someone is in the menu would commit them.
This can't be detected from the wire; it is documented in the endpoint and
audited.
- **Target file:** the active setup, overwritten in place, by default. A
named target is allowed, but overwriting a *non-active* setup or
`factory.MMB` is untested, so it is refused in this phase.
---
## Testing
**Offline (CI-capable):**
- **Frame reproduction.** The new encoder must reproduce THOR's captured write
frames byte for byte: `0x96`/`0x97`, `0x7E`/`0x7F`, and the full setup push,
from the 9-24 / 9-25 / 10-14 captures. This is the same method that proved
the reads (218/218). The needed frames are copied into force-added fixtures,
since `bridges/captures/` is gitignored.
- **Safety layer on fakes:**
- series by prefix
- identity mismatch → 409, nothing sent
- `0xA2` refused
- lock → 423
- read-back mismatch → failed change
- audit row written for every change attempt
- RADIO RING → session ends
- **Endpoints** through FastAPI's `TestClient` against the scripted transport
already used in `tests/test_micromate_client.py`.
- **Contract tests.** The same test, run against both adapters with fakes,
asserts that each job returns the same model with the same field names and
units. A field present for one series and absent for the other is a test
failure unless it lives under `detail`. This is the test that keeps the
guiding principle true as the code grows.
**Bench (UM20147, with Brian):** each write's first live send follows the same
protocol:
1. Dry run.
2. Review the frames.
3. Send once, with a capture running.
4. Read back.
5. Write the result into the reference.
Order: stop/start → call-home off/on → setup push of one field → setup push of
several fields.
**Series-3 session test (before Series-3 sessions are built):** hold a call-up
session open to a MiniMate that is monitoring, for several minutes. Record:
- does it keep monitoring (does an event still record)?
- after hangup, is it monitoring?
- does it behave differently on an RV55 with the DCD issue?
---
## Build phases
Each safety piece arrives with its first real use, so nothing sits untested.
1. **One contract, reads only.** `device_access.py`, the two adapters, the
shared models, series selection, the per-unit lock, the error mapping, and
sessions with ring safety. Rows 1–5 for **both** series through the same
endpoints. **No writes.** Split into three plans:
- 1a. The foundation plus identify / status / settings for both series.
- 1b. Event list and download for both series (rows 4–5).
- 1c. **The webapp:** serial + address, and the same read panels for both
series.
- **HARD PREREQUISITE:** before any poller or webapp sends `serial`, add a
per-address cool-down after a RADIO RING: call-ups to that address answer
503 + `Retry-After` until it expires, and `POST /device/hangup` clears it.
The length must come from the unit's measured call-home retry timing (a
bench test). Without it a poller can re-grab the modem's single TCP
session through every retry, and the call never reaches THOR.
2. **Encoder + opcode guard + dry run + frame-reproduction tests.** Still
nothing sent.
3. **Start/stop monitoring** (row 7): the first live write, at the bench.
Brings the identity check, the audit table and the read-back framework.
4. **Call-home enable/disable** (row 9).
5. **Setup push** (row 10): one field first, then several.
Each phase is its own implementation plan. **All phases land on
`feat/series4-sfm-parity` and merge to `dev` once, when everything here is
implemented** (Brian, 2026-10-21) — not one merge per phase.
---
## Out of scope (this phase)
- Series-4 emergency tools: runaway stops, rescue, per-event delete, erase.
(Erase-all is also unmapped.)
- Async jobs; auth (Terra-View as jump host); the call-home receiver. These
are shared features for later.
- Scheduler read/write/enable; clock set; remote sensor check; restart;
firmware.
- Series-3 sessions, pending the bench test.
- Mapping the rest of `0x2C` (the THOR round).
## Fix list (found 2026-10-19, separate small changes)
- `bridges/ach_server.py:524`: `seen_keys` is undefined. Series-3 call-home
monitor-log collection has failed every session since `9afa348`
(2026-05-07).
- `bridges/mm_ach_server.py:262`: `_cstring`/`_content` aren't imported, so
the ring-answer path would raise `NameError`. From `8f67608` (2026-10-14).
- Series-3 `5A` 64 KB page-boundary bug (known; surfaces as HTTP 500).
- `POST /device/config` writes a fixed 29-byte `0x82` blob from one 3-11-26
capture, whatever the unit's trigger settings.
- `/device/events` runs a full 5A download per event just to list headers.
- `0x08` is named `read_event_index` in `micromate/`; it is the preferences
block.
## Left open by the phase 1a review (2026-10-21)
Minor findings from the whole-branch review, parked here so they outlive the
plan's scratch ledger. None blocks 1a; the phase each one matters to is named.
- **CORS ordering (1c, if a browser calls SFM directly).** The `/device` guard
middleware is registered after CORS, so it sits outside it: its 409/501
responses carry no `access-control-allow-origin`, and an OPTIONS preflight to
a guarded URL gets the guard's refusal instead of CORS's 200. Register CORS
last, or let OPTIONS through. Terra-View proxies server-side and is not
affected.
- **Legacy handlers take no unit lock (1c / phase 3).** The guard checks for a
held line and then lets the legacy handler run unlocked; a legacy request
admitted just before a Series-4 call-up at the same address can overlap it.
- **Address keys are not normalised.** `tcp:<host>:<port>` is the raw string:
a hostname vs an IP, or `/dev/serial/by-id/...` vs `/dev/ttyACM0`, gets two
locks for one link.
- **A serial-less request to an UNHELD Micromate still runs Series-3 bytes.**
The guard only knows about lines SFM holds. This is the phase-2 opcode
guard's job.
- **`tcp_port` coercion mismatch.** The guard parses with `int()`, pydantic
coerces more loosely (`"9034.0"`), so such a request passes the guard
unchecked. Parse with pydantic's own int coercion, or fail closed.
- **Test gaps.** The middleware wrapper itself is untested (a raw ASGI call
works without httpx); the contract test compares field names of one shared
dataclass, which cannot fail, and does not enforce "a field absent for one
series lives under `detail`".
- **`_ensure_reaper` race.** Two first Series-4 requests at once can start two
reaper threads; harmless because `try_hold` keeps them off each other's units.
- **Held serial lines share `/dev/ttyACM0` silently.** pyserial's open is not
exclusive, so a bench script beside a held line interleaves bytes with the
keep-alive; it looks like a dead unit. Open with `exclusive=True`, or don't
hold serial links.
## Table 2: to be added later (both series)
| area | item |
|---|---|
| infrastructure | async jobs; auth via Terra-View |
| THOR has it, SFM doesn't | clock set; remote sensor check; scheduler; one setup to many units; restart |
| call-home receiver | hold lines open (S4); "already downloaded" tracking; rules by serial prefix (copy events, monitor log, delete, set clock); detect "Monitor While Calling Home" blocking deletes (⚠ one unexplained 21 → 5 count drop in THOR's log); hand off to `/db/import/*` instead of the watchers |
| settings, the no-PC-files way | intended settings per deployment; drift report (intended vs actual); push then verify |
| notifications | email/SMS by event type and PPV (THOR does it; may belong in Terra-View) |
| emergency tools for S4 | if a Micromate ever needs them |
## Parking lot
**Monitor logs.** Its own piece of work, data side as much as device side.
A unit calls in at least once or twice a day. With no events (e.g. waveform
mode, no blast that day) it still delivers a **monitor log**: "monitoring from
X to Y". The watchers (one for BW-ACH / Series 3, one for THOR-ACH / Series 4)
use the newest file per unit, event or `.MLG`, as SFM's "last heard from" age.
They forward waveform and histogram files but **not** monitor logs. To decide:
- Ingest call-in monitor logs into SFM. SFM's DB **already has** a
`monitor_log` table (one row per interval, deduped by serial + start time),
and `minimateplus/blastware_file.py` already parses Series-3 `.MLG`.
Missing: anything that takes `.MLG` in from the watchers, and knowledge of
THOR's Series-4 monitor-log file format.
- A live monitor-log read over a connection (Series 4: `0x0A` exists, no
wrapper or decoder; Series 3 in SFM: none).
- What it is for: proof of coverage ("was it monitoring when they blasted?")
and visible gaps.
- Related fix-list item: `ach_server.py`'s `seen_keys`.
**How SFM handles setup files and schedules.** This phase only reads and
pushes the unit's *active* setup, with no PC-side library (the `.mmb`
same-name/different-contents gotcha). Still to decide, as one question because
the two are coupled:
- The unit stores up to 25 named `.MMB` files. Should SFM manage them (list,
select, rename, delete, push to a named file), or only ever touch the active
one?
- **Schedules name setup files.** A schedule entry switches the unit to a
setup by name, so a schedule is only as reliable as the files it points to.
What if it points to a file that isn't there? That is untested.
- How "intended settings per deployment" (Table 2) fits with files and
schedules.
- Scheduler read/write is mostly mapped (file transfer + `0x47`); **disable has
never been captured**.
**A modem-side agent on the RX55.** AirLink
OS on the RX55 has "Container Applications (Early Adopter)", and Brian already
runs `slmm-proxy` there. A small program owning the unit's serial port could:
- let THOR and SFM share the line
- dial out to SFM, avoiding the IP whitelist
- handle `RADIO RING` locally
- **Brian's hunch:** make RX55s work with Series 3 by driving DTR/DCD itself
Open questions:
- Can a container open the RS-232 port?
- Can it set the control lines?
- How is it deployed to a fleet, and does it Autostart?
- Will a firmware update keep the beta feature?
## Open questions this design leaves for the bench
- The ack for start/stop when the unit is already in that state.
- The offset rule, and whether `0x68`/`0x82` are required, for the setup push.
- Whether the device ever refuses a write while monitoring. Only THOR's policy
has been seen.
- How a failed write is signalled. It has never been observed.
- MiniMate behaviour with a held session (above).
+26 -1
View File
@@ -53,6 +53,11 @@ CONTENT = 11
# two of them disagree with docs/micromate_protocol_reference.md. # two of them disagree with docs/micromate_protocol_reference.md.
_STATE_FLAG = 0 # 0x49: 0x00 idle, 0x02 monitoring _STATE_FLAG = 0 # 0x49: 0x00 idle, 0x02 monitoring
# 0x06 storage range. content[0:4] is the event count: 3/3 against the chain
# walk, and THOR's ReadEventRecordCount agrees. content[4:8] is very likely
# the monitor-log count -- graded a strong candidate, not settled, so not exposed.
_SR_EVENT_COUNT = slice(0, 4)
_MS_FLAG = 1 # 0x1C: monitoring flag — test NON-ZERO _MS_FLAG = 1 # 0x1C: monitoring flag — test NON-ZERO
_MS_DAY, _MS_MONTH, _MS_YEAR = 2, 3, slice(4, 6) _MS_DAY, _MS_MONTH, _MS_YEAR = 2, 3, slice(4, 6)
_MS_UNKNOWN_6 = 6 # ⚠ sub-second tick (~4020/s, step 4, 64 ms wrap) — NOT the hour _MS_UNKNOWN_6 = 6 # ⚠ sub-second tick (~4020/s, step 4, 64 ms wrap) — NOT the hour
@@ -128,7 +133,10 @@ class MicromateClient:
self._transport.disconnect() self._transport.disconnect()
def is_open(self) -> bool: def is_open(self) -> bool:
return self._transport.is_connected() # `is_connected` is a PROPERTY on BaseTransport. Calling it raised
# TypeError on every real transport; only a test double that defined
# it as a method hid that.
return bool(self._transport.is_connected)
def __enter__(self) -> "MicromateClient": def __enter__(self) -> "MicromateClient":
self.open() self.open()
@@ -261,6 +269,23 @@ class MicromateClient:
raw=data, raw=data,
) )
def get_event_count(self) -> int:
"""`SUB 0x06` -- events stored. One read; no chain walk."""
c = _content(self._proto.read_storage_range())
if len(c) < 4:
raise ProtocolError(f"storage range content is {len(c)} B, need at least 4")
return int.from_bytes(c[_SR_EVENT_COUNT], "big")
def read_unsolicited(self) -> bytes:
"""Whatever the unit sent unprompted. **Sends nothing.**
One transport read. Bytes between commands are noise to the protocol
(every request resets the parser), so reading them here takes nothing
the protocol needs. A session calls this while idle to notice
RADIO RING without waiting for its next keep-alive.
"""
return self._transport.read(4096)
@staticmethod @staticmethod
def _parse_clock(c: bytes) -> Optional[datetime.datetime]: def _parse_clock(c: bytes) -> Optional[datetime.datetime]:
"""The unit's own clock, in its own local time. """The unit's own clock, in its own local time.
+9
View File
@@ -0,0 +1,9 @@
"""One door for every device request -- see the 2026-10-20 parity spec."""
from .errors import (
BadRequest, CallHomeInProgress, ConnectFailed, DeviceError, MalformedReply,
NoAnswer, NotSupported, UnitBusy, WrongUnit, translate,
)
from .models import UnitAddress, UnitInfo, UnitSettings, UnitStatus
from .series import normalise_serial, series_for_serial
from .locks import UnitLocks
from .access import DeviceAccess
+179
View File
@@ -0,0 +1,179 @@
"""DeviceAccess -- the one door every device request passes through.
The control surface does not care which series it is talking to; this does.
"""
from __future__ import annotations
import logging
import threading
import time
from typing import Any, Callable, Dict, Optional
from .errors import ConnectFailed, DeviceError, NoAnswer, WrongUnit
from .locks import UnitLocks
from .models import UnitAddress, UnitInfo, UnitSettings, UnitStatus
from .s3 import Series3Adapter, default_s3_client_factory
from .s4 import (
Series4Session, default_s4_client_factory, s4_identify, s4_settings, s4_status,
)
from .series import normalise_serial, series_for_serial
log = logging.getLogger("sfm.device_access")
class DeviceAccess:
def __init__(
self, *,
s3_client_factory: Callable[[UnitAddress], Any] = default_s3_client_factory,
s4_client_factory: Callable[[UnitAddress], Any] = default_s4_client_factory,
clock: Callable[[], float] = time.monotonic,
lock_timeout: float = 20.0,
keepalive_s: float = 60.0,
idle_hangup_s: float = 300.0,
reaper_interval_s: float = 5.0,
start_reaper: bool = True,
) -> None:
self._locks = UnitLocks(lock_timeout)
self._s3 = Series3Adapter(s3_client_factory)
self._s4_factory = s4_client_factory
self._clock = clock
self._keepalive_s = keepalive_s
self._idle_hangup_s = idle_hangup_s
self._reaper_interval_s = reaper_interval_s
self._start_reaper = start_reaper
self._reaper: Optional[threading.Thread] = None
self._sessions: Dict[str, Series4Session] = {}
self._sessions_guard = threading.Lock()
# ── public operations ─────────────────────────────────────────────────────
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
return self._dispatch(address, serial, self._s3.identify, s4_identify)
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
return self._dispatch(address, serial, self._s3.status, s4_status)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
return self._dispatch(address, serial, self._s3.settings, s4_settings)
def held_serial(self, address: UnitAddress) -> Optional[str]:
"""Serial of the OPEN held Series-4 line at this address, else None. No I/O."""
with self._sessions_guard:
session = self._sessions.get(address.key)
if session is not None and session.is_open:
return session.serial
return None
def hang_up(self, address: UnitAddress) -> bool:
with self._locks.hold(address.key):
with self._sessions_guard:
session = self._sessions.pop(address.key, None)
if session is None:
return False
was_open = session.is_open
session.hang_up()
return was_open
# ── dispatch ──────────────────────────────────────────────────────────────
def _dispatch(self, address: UnitAddress, serial: str,
s3_op: Callable[[UnitAddress, str], Any],
s4_op: Callable[[Any, str], Any]) -> Any:
serial = normalise_serial(serial)
series = series_for_serial(serial) # raises BadRequest before any I/O
with self._locks.hold(address.key):
if series == 3:
with self._sessions_guard:
held = self._sessions.get(address.key)
if held is not None and held.is_open:
raise WrongUnit(
f"a Series-4 line to {held.serial} is held at {address.key}; "
"a Series-3 unit cannot be there -- POST /device/hangup first "
"if the modem has moved")
return s3_op(address, serial)
session = self._session_for(address, serial)
was_held = session.is_open
try:
return session.run(lambda client: s4_op(client, serial))
except DeviceError as exc:
self._forget_if_closed(address, session)
# A held line the peer dropped still reads open (the transport only
# learns at EOF), so the first request on it times out or fails.
# Call up fresh and retry ONCE. Safe only because phase 1a
# operations are reads (idempotent); writes (phase 3) must NOT
# inherit this -- a write whose ack was lost must never be sent twice.
if was_held and isinstance(exc, (NoAnswer, ConnectFailed)):
self._drop(address.key, session)
session.hang_up()
session = self._session_for(address, serial)
try:
return session.run(lambda client: s4_op(client, serial))
except DeviceError:
self._forget_if_closed(address, session)
raise
raise
def _forget_if_closed(self, address: UnitAddress, session: Series4Session) -> None:
if not session.is_open:
self._drop(address.key, session)
def _session_for(self, address: UnitAddress, serial: str) -> Series4Session:
with self._sessions_guard:
session = self._sessions.get(address.key)
if session is not None and session.serial != serial:
if session.is_open:
raise WrongUnit(
f"a Series-4 line to {session.serial} is held at {address.key}; "
f"{serial} cannot be reached there -- POST /device/hangup first "
"if the modem has moved")
session = None
if session is None:
session = Series4Session(address, serial, self._s4_factory, clock=self._clock)
self._sessions[address.key] = session
self._ensure_reaper()
return session
# ── the reaper ────────────────────────────────────────────────────────────
def tick(self, now: Optional[float] = None) -> None:
"""Per held line: hang up if idle, else keep alive, else listen for a ring."""
now = self._clock() if now is None else now
with self._sessions_guard:
items = list(self._sessions.items())
for key, session in items:
with self._locks.try_hold(key) as held:
if not held:
continue # mid-request: not idle
if not session.is_open:
self._drop(key, session)
continue
try:
if now - session.last_used >= self._idle_hangup_s:
session.hang_up()
self._drop(key, session)
elif now - session.last_traffic >= self._keepalive_s:
session.keepalive()
else:
session.listen()
except DeviceError as exc:
log.warning("held line %s closed: %s", key, exc)
self._drop(key, session)
def _drop(self, key: str, session: Series4Session) -> None:
with self._sessions_guard:
if self._sessions.get(key) is session:
del self._sessions[key]
def _ensure_reaper(self) -> None:
if not self._start_reaper or self._reaper is not None:
return
self._reaper = threading.Thread(target=self._reaper_loop, name="sfm-held-lines", daemon=True)
self._reaper.start()
def _reaper_loop(self) -> None:
while True:
time.sleep(self._reaper_interval_s)
try:
self.tick()
except Exception: # noqa: BLE001
log.exception("held-line reaper tick failed")
+63
View File
@@ -0,0 +1,63 @@
"""Typed device errors, each with the HTTP status the endpoints return."""
from __future__ import annotations
import micromate.protocol as _mm_proto
import minimateplus.protocol as _mmp_proto
class DeviceError(Exception):
http_status = 500
class BadRequest(DeviceError):
http_status = 422
class NotSupported(DeviceError):
http_status = 501
class WrongUnit(DeviceError):
http_status = 409
class UnitBusy(DeviceError):
http_status = 423
class ConnectFailed(DeviceError):
http_status = 503
class CallHomeInProgress(DeviceError):
http_status = 503
class NoAnswer(DeviceError):
http_status = 504
class MalformedReply(DeviceError):
http_status = 502
_TIMEOUTS = (_mm_proto.TimeoutError, _mmp_proto.TimeoutError)
_PROTOCOL = (_mm_proto.ProtocolError, _mmp_proto.ProtocolError)
def translate(exc: BaseException, *, connecting: bool) -> DeviceError:
"""Map a library exception to a typed error.
Order matters: each library's TimeoutError is a ProtocolError subclass, and
the builtin TimeoutError (a failed TCP connect) is an OSError.
"""
if isinstance(exc, DeviceError):
return exc
if isinstance(exc, _TIMEOUTS):
return NoAnswer(f"the unit did not answer: {exc}")
if isinstance(exc, _PROTOCOL):
return MalformedReply(f"bad reply from the unit: {exc}")
if isinstance(exc, OSError):
what = "could not connect" if connecting else "connection lost"
return ConnectFailed(f"{what}: {exc}")
return DeviceError(f"device error: {exc}")
+41
View File
@@ -0,0 +1,41 @@
"""One connection per unit. A modem allows a single TCP session, so two
requests must take turns instead of opening a second connection."""
from __future__ import annotations
import threading
from contextlib import contextmanager
from typing import Dict, Iterator, Optional
from .errors import UnitBusy
class UnitLocks:
def __init__(self, timeout: float = 20.0) -> None:
self._timeout = timeout
self._guard = threading.Lock()
self._locks: Dict[str, threading.Lock] = {}
def _lock_for(self, key: str) -> threading.Lock:
with self._guard:
return self._locks.setdefault(key, threading.Lock())
@contextmanager
def hold(self, key: str, timeout: Optional[float] = None) -> Iterator[None]:
lock = self._lock_for(key)
wait = self._timeout if timeout is None else timeout
if not lock.acquire(timeout=wait):
raise UnitBusy(f"the unit at {key} is busy with another request; try again shortly")
try:
yield
finally:
lock.release()
@contextmanager
def try_hold(self, key: str) -> Iterator[bool]:
lock = self._lock_for(key)
got = lock.acquire(blocking=False)
try:
yield got
finally:
if got:
lock.release()
+68
View File
@@ -0,0 +1,68 @@
"""Series-neutral models. Every operation returns the same shape for both
series; anything only one series has goes under `detail`."""
from __future__ import annotations
from dataclasses import dataclass, field
from typing import Any, Dict, Optional
from .errors import BadRequest
@dataclass(frozen=True)
class UnitAddress:
host: Optional[str]
tcp_port: Optional[int]
port: Optional[str]
baud: Optional[int]
def __post_init__(self) -> None:
if not self.host and not self.port:
raise BadRequest(
"specify 'host' (TCP, e.g. ?host=10.0.0.5&tcp_port=9034) "
"or 'port' (serial, e.g. ?port=/dev/ttyACM0)"
)
@property
def key(self) -> str:
"""One key per physical link -- what the per-unit lock is keyed on."""
if self.host:
return f"tcp:{self.host}:{self.tcp_port}"
return f"serial:{self.port}"
@dataclass
class UnitInfo:
serial: str
series: int
model: Optional[str]
firmware: Optional[str]
monitoring: Optional[bool]
active_setup: Optional[str]
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class UnitStatus:
serial: str
series: int
monitoring: bool
battery_volts: Optional[float]
memory_total_bytes: Optional[int]
memory_free_bytes: Optional[int]
device_time: Optional[str] # ISO, the unit's own local time
event_count: Optional[int] # None where it is not cheap (Series 3)
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class UnitSettings:
serial: str
series: int
setup_name: Optional[str]
record_mode: Optional[str] # the unit's own name for its mode
sample_rate: Optional[int]
record_time_s: Optional[float]
histogram_interval_s: Optional[int]
geo_trigger_ips: Optional[float]
notes: Dict[str, str] = field(default_factory=dict)
detail: Dict[str, Any] = field(default_factory=dict)
+123
View File
@@ -0,0 +1,123 @@
"""Series-3 adapter. Connect-per-request, as SFM has always done for
MiniMates -- a held session waits for the bench test in the spec."""
from __future__ import annotations
import logging
from typing import Any, Callable
from minimateplus import MiniMateClient
from minimateplus.transport import TcpTransport
from .errors import DeviceError, MalformedReply, NoAnswer, WrongUnit, translate
from .models import UnitAddress, UnitInfo, UnitSettings, UnitStatus
log = logging.getLogger("sfm.device_access")
S3_DEFAULT_BAUD = 38400
S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"}
def default_s3_client_factory(address: UnitAddress, timeout: float = 10.0) -> MiniMateClient:
if address.host:
return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port), timeout=timeout)
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
class Series3Adapter:
def __init__(self, client_factory: Callable[[UnitAddress], Any] = default_s3_client_factory) -> None:
self._factory = client_factory
def _run(self, address: UnitAddress, fn: Callable[[Any], Any]) -> Any:
def attempt() -> Any:
client = self._factory(address)
try:
client.open()
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
try:
return fn(client)
except DeviceError:
raise
except Exception as exc:
raise translate(exc, connecting=False) from exc
finally:
_close(client)
try:
return attempt()
except NoAnswer:
# A MiniMate that has just had its serial lines asserted can take
# 5-10 s to boot, and shows it as silence; one retry covers it. TCP
# only -- on a serial cable a silence is a real fault. Narrower than
# server._run_with_retry (any protocol error): retrying a
# MalformedReply would also retry "no settings block", which a
# reconnect cannot fix.
if not address.host:
raise
log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key)
return attempt()
@staticmethod
def _check(serial_reported: str, serial: str, address: UnitAddress) -> None:
if (serial_reported or "").strip().upper() != serial:
raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}")
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
def op(client: Any) -> UnitInfo:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
return UnitInfo(
serial=info.serial, series=3, model=info.model, firmware=info.firmware_version,
monitoring=None, active_setup=cc.setup_name if cc else None,
detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version},
)
return self._run(address, op)
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
def op(client: Any) -> UnitStatus:
client.poll()
ms = client.get_monitor_status()
return UnitStatus(
serial=serial, series=3, monitoring=ms.is_monitoring,
battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None,
memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free,
device_time=None, event_count=None,
# Series 3 status reads no serial, so the serial shown is the one requested, not one the unit reported.
detail={"serial_verified": False},
)
return self._run(address, op)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
def op(client: Any) -> UnitSettings:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
if cc is None:
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
mode = None
if cc.recording_mode is not None:
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
notes = {
label: value for label, value in (
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
) if value is not None
}
return UnitSettings(
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
notes=notes,
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
"geo_range": cc.geo_range},
)
return self._run(address, op)
+240
View File
@@ -0,0 +1,240 @@
"""Series-4 sessions: call up once, stay on the line, hang up when idle.
⚠ Imports only minimateplus.transport from the Series-3 package. Nothing
here may build or send a Series-3 frame -- SESSION_RESET (41 03) has never
been sent to a Micromate.
"""
from __future__ import annotations
import logging
import time
from typing import Any, Callable, Optional, TypeVar
from micromate.client import MicromateClient
from minimateplus.transport import BaseTransport, SerialTransport, TcpTransport
from .errors import CallHomeInProgress, WrongUnit, translate
from .models import UnitAddress, UnitInfo, UnitSettings, UnitStatus
from .series import normalise_serial
log = logging.getLogger("sfm.device_access")
T = TypeVar("T")
RING = b"RADIO RING"
S4_DEFAULT_BAUD = 115200
class RingDetected(Exception):
"""The unit sent RADIO RING: it is calling home up this connection."""
class RingWatchTransport(BaseTransport):
"""Passes bytes through; raises RingDetected the moment RADIO RING appears
OUTSIDE a frame, including when it is split across two reads.
Inside a frame the bytes are data: the 0x2C call-home config block's dial
string is literally "RADIO RING". A frame runs from STX to an unescaped
ETX; inside it DLE escapes the next byte.
"""
_STX, _ETX, _DLE = 0x02, 0x03, 0x10
def __init__(self, inner: BaseTransport) -> None:
self._inner = inner
self._tail = b""
self._in_frame = False
self._escaped = False
def connect(self) -> None:
self._inner.connect()
def disconnect(self) -> None:
self._inner.disconnect()
@property
def is_connected(self) -> bool:
return self._inner.is_connected
def write(self, data: bytes) -> None:
# A request starts a new exchange (MicromateProtocol resets its parser
# here too), so a stray STX on an idle line cannot hide the next ring.
self._in_frame = self._escaped = False
self._inner.write(data)
def read(self, n: int) -> bytes:
data = self._inner.read(n)
for b in data:
if self._in_frame:
if self._escaped:
self._escaped = False
elif b == self._DLE:
self._escaped = True
elif b == self._ETX:
self._in_frame = False
elif b == self._STX:
self._in_frame = True
self._tail = b""
else:
self._tail = (self._tail + bytes([b]))[-len(RING):]
if self._tail == RING:
self._tail = b""
raise RingDetected("RADIO RING")
return data
def default_s4_client_factory(address: UnitAddress, recv_timeout: float = 10.0) -> MicromateClient:
if address.host:
inner: BaseTransport = TcpTransport(address.host, port=address.tcp_port)
else:
inner = SerialTransport(address.port, address.baud or S4_DEFAULT_BAUD)
return MicromateClient(RingWatchTransport(inner), recv_timeout=recv_timeout)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
_RING_MESSAGE = ("the unit started calling home; SFM hung up so the call can "
"reach THOR -- try again in a few minutes")
class Series4Session:
"""One held line to one Micromate.
`last_used` is the last *user* request: the idle hang-up measures it.
`last_traffic` is any exchange, keep-alives included: the keep-alive
schedule measures it. If keep-alives counted as use, the line would never
go idle.
"""
def __init__(self, address: UnitAddress, serial: str,
client_factory: Callable[[UnitAddress], Any],
clock: Callable[[], float] = time.monotonic) -> None:
self.address = address
self.serial = normalise_serial(serial)
self._factory = client_factory
self._clock = clock
self._client: Optional[Any] = None
self.info = None
self.last_used = clock()
self.last_traffic = self.last_used
@property
def is_open(self) -> bool:
client = self._client # one read: held_serial() calls this without the unit lock
return client is not None and client.is_open()
def call_up(self):
client = self._factory(self.address)
try:
client.open()
info = client.connect()
except RingDetected as exc:
_close(client)
log.warning("RADIO RING from %s during call-up -- released the line", self.address.key)
raise CallHomeInProgress(_RING_MESSAGE) from exc
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
if normalise_serial(info.serial) != self.serial:
_close(client)
raise WrongUnit(f"asked for {self.serial} but {info.serial} answered at {self.address.key}")
self._client, self.info = client, info
self.last_used = self.last_traffic = self._clock()
log.info("call-up: %s at %s, staying on the line", self.serial, self.address.key)
return info
def _exchange(self, op: Callable[[Any], T]) -> T:
try:
return op(self._client)
except RingDetected as exc:
self.hang_up()
log.warning("RADIO RING from %s -- released the line so the call reaches THOR",
self.address.key)
raise CallHomeInProgress(_RING_MESSAGE) from exc
except Exception as exc:
self.hang_up()
raise translate(exc, connecting=False) from exc
def run(self, op: Callable[[Any], T]) -> T:
"""A user request. Calls up first if the line is not open."""
if not self.is_open:
self.call_up()
result = self._exchange(op)
self.last_used = self.last_traffic = self._clock()
return result
def keepalive(self) -> None:
"""A POLL so the modem's idle timer does not drop the line. Not use."""
if not self.is_open:
return
self._exchange(lambda c: c.protocol.poll())
self.last_traffic = self._clock()
def listen(self) -> None:
"""Read anything the unit sent unprompted; send nothing. Not use."""
if not self.is_open:
return
self._exchange(lambda c: c.read_unsolicited())
def hang_up(self) -> None:
if self._client is not None:
_close(self._client)
self._client = None
log.info("hang-up: %s at %s", self.serial, self.address.key)
# ── Operations (each runs inside Series4Session.run) ──────────────────────────
def s4_identify(client: Any, serial: str) -> UnitInfo:
info = client.connect()
return UnitInfo(
serial=info.serial, series=4, model=info.model,
firmware=None, # the version string lives in 0x01, undecoded
monitoring=info.monitoring, active_setup=info.active_setup,
detail={"manufacturer": info.manufacturer, "firmware_line": info.firmware_line},
)
def s4_status(client: Any, serial: str) -> UnitStatus:
st = client.get_state()
count = client.get_event_count()
return UnitStatus(
serial=serial, series=4, monitoring=st.monitoring, battery_volts=st.battery_volts,
memory_total_bytes=st.memory_total_bytes, memory_free_bytes=st.memory_free_bytes,
device_time=st.device_time.isoformat() if st.device_time else None,
event_count=count,
)
def s4_settings(client: Any, serial: str) -> UnitSettings:
s = client.get_setup()
return UnitSettings(
serial=serial, series=4, setup_name=s.name, record_mode=s.record_mode_name,
sample_rate=s.sample_rate, record_time_s=s.record_time_s,
histogram_interval_s=s.histogram_interval_s,
geo_trigger_ips=s.geo_trigger_ips[0], # the keypad writes all three the same
notes=dict(s.notes),
detail={
"pretrigger_s": s.pretrigger_s,
"auto_record_stop": s.auto_record_stop,
"auto_stop_after_s": s.auto_stop_after_s,
"geophones_active": s.geophones_active,
"mic_active": s.mic_active,
"trigger_on_geophones": s.trigger_on_geophones,
"trigger_on_mic": s.trigger_on_mic,
"geo_trigger_ips_per_channel": list(s.geo_trigger_ips),
"mic_type": s.mic_type,
"mic_trigger_psi": s.mic_trigger_psi,
"mic_trigger_db": s.mic_trigger_db,
"job_number_enabled": s.job_number_enabled,
"job_number": s.job_number,
"scaled_distance_enabled": s.scaled_distance_enabled,
"distance_ft": s.distance_ft,
"charge_weight_lb": s.charge_weight_lb,
"scaled_distance": s.scaled_distance,
},
)
+20
View File
@@ -0,0 +1,20 @@
"""Which series a unit is, from its serial prefix (decided with Brian, 2026-10-20)."""
from __future__ import annotations
from .errors import BadRequest
SERIES_BY_PREFIX = {"UM": 4, "BE": 3, "BA": 3}
def normalise_serial(serial: str) -> str:
return (serial or "").strip().upper()
def series_for_serial(serial: str) -> int:
s = normalise_serial(serial)
for prefix, series in SERIES_BY_PREFIX.items():
if s.startswith(prefix) and len(s) > len(prefix):
return series
raise BadRequest(
f"unknown serial {serial!r}: expected UM... (Series 4) or BE.../BA... (Series 3)"
)
+133 -5
View File
@@ -13,6 +13,14 @@ GET /device/info POLL + serial number + full config read
GET /device/events Download all stored events (headers + peak values) GET /device/events Download all stored events (headers + peak values)
POST /device/connect Explicit connect/identify (same as /device/info) POST /device/connect Explicit connect/identify (same as /device/info)
GET /device/event/{idx} Single event by index (header + waveform record) GET /device/event/{idx} Single event by index (header + waveform record)
GET /device/settings Recording settings (requires serial)
POST /device/hangup Hang up a held Series-4 line
`serial` on /device/info, /device/connect, /device/monitor/status and
/device/settings names the unit (UM... = Series 4, BE.../BA... = Series 3) and
returns the shared model. Without it, the legacy Series-3 behaviour is
unchanged. Series-4 lines are held open between requests and hung up after
5 idle minutes, on POST /device/hangup, or the moment the unit calls home.
Transport query params (supply one set): Transport query params (supply one set):
Serial (direct RS-232 cable): Serial (direct RS-232 cable):
@@ -42,7 +50,7 @@ import tempfile
import threading import threading
import time import time
from pathlib import Path from pathlib import Path
from typing import Optional from typing import Mapping, Optional
# FastAPI / Pydantic # FastAPI / Pydantic
try: try:
@@ -74,6 +82,10 @@ from sfm.database import SeismoDb
from sfm.live_cache import LiveCache as _LiveCache from sfm.live_cache import LiveCache as _LiveCache
from sfm.waveform_store import WaveformStore from sfm.waveform_store import WaveformStore
from sfm import db_snapshot from sfm import db_snapshot
import dataclasses
from sfm.device_access import DeviceAccess, DeviceError, UnitAddress
from sfm.device_access.errors import BadRequest
from sfm.device_access.series import normalise_serial
logging.basicConfig( logging.basicConfig(
level=logging.INFO, level=logging.INFO,
@@ -340,6 +352,81 @@ def _run_with_retry(fn, *, is_tcp: bool):
return fn() # let any second failure propagate normally return fn() # let any second failure propagate normally
# ── Device access (serial-named requests) ─────────────────────────────────────
# A request that names the unit by `serial` goes through sfm.device_access:
# same contract for Series 3 and 4. Without `serial`, handlers run their
# legacy Series-3 path unchanged (spec 2026-10-20).
# Constructing it does no I/O and starts no thread until a Series-4 session exists.
_device_access_instance: DeviceAccess = DeviceAccess()
def _device_access() -> DeviceAccess:
return _device_access_instance
def _unit_address(port: Optional[str], baud: Optional[int], host: Optional[str],
tcp_port: int) -> UnitAddress:
return UnitAddress(host=host, tcp_port=tcp_port if host else None,
port=None if host else port, baud=baud)
def _via_device_access(fn) -> dict:
try:
result = fn()
except DeviceError as exc:
raise HTTPException(status_code=exc.http_status, detail=str(exc)) from exc
return dataclasses.asdict(result) if dataclasses.is_dataclass(result) else result
_SERIAL_AWARE_PATHS = frozenset({
"/device/info", "/device/connect", "/device/monitor/status", "/device/settings",
})
def _device_guard(path: str, query: Mapping[str, str]) -> Optional[tuple]:
"""Refuse a /device/* request that would reach the wrong series' code.
FastAPI drops query params a route does not declare, so `?serial=UM...` on
a Series-3 route would silently run Series-3 bytes against a Micromate
(0xA2 is CONFIRM ERASE there). Returns (status, detail) to refuse, or None.
/device/hangup is always allowed: it must always be able to release a line.
"""
if not path.startswith("/device/") or path == "/device/hangup":
return None
serial = normalise_serial(query.get("serial") or "")
if serial and path in _SERIAL_AWARE_PATHS:
return None # DeviceAccess routes by series and checks held lines itself
if serial.startswith("UM"):
return 501, f"not supported for Series 4 yet: {path}"
# Everything else runs the legacy Series-3 handler -- whatever serial it
# carried, FastAPI drops it -- so it must not reach a held Series-4 line.
if not (query.get("host") or query.get("port")):
return None
try:
tcp_port = int(query.get("tcp_port") or DEFAULT_TCP_PORT)
# baud is not part of the address key, so it is not parsed here.
addr = _unit_address(query.get("port") or None, None, query.get("host") or None, tcp_port)
except (BadRequest, ValueError):
return None
held = _device_access().held_serial(addr)
if held is not None:
return 409, (f"a Series-4 line to {held} is held at {addr.key}; "
"POST /device/hangup first")
return None
@app.middleware("http")
async def _device_guard_middleware(request, call_next):
refusal = _device_guard(request.url.path, request.query_params)
if refusal is not None:
return JSONResponse(status_code=refusal[0], content={"detail": refusal[1]})
return await call_next(request)
_SERIAL_DOC = "Unit serial -- UM... (Series 4) or BE.../BA... (Series 3). Returns the shared model."
# ── Helpers ──────────────────────────────────────────────────────────────────── # ── Helpers ────────────────────────────────────────────────────────────────────
def _backfill_events(events: list, info: "DeviceInfo") -> None: def _backfill_events(events: list, info: "DeviceInfo") -> None:
@@ -404,10 +491,11 @@ def event_browser():
@app.get("/device/info") @app.get("/device/info")
def device_info( def device_info(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5, /dev/ttyUSB0)"), port: Optional[str] = Query(None, description="Serial port (e.g. COM5, /dev/ttyUSB0)"),
baud: int = Query(38400, description="Serial baud rate (default 38400)"), baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay (e.g. 203.0.113.5)"), host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay (e.g. 203.0.113.5)"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"), tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
force: bool = Query(False, description="Bypass cache and re-read from device"), force: bool = Query(False, description="Bypass cache and re-read from device"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
) -> dict: ) -> dict:
""" """
Connect to the device, perform the POLL startup handshake, and return Connect to the device, perform the POLL startup handshake, and return
@@ -421,6 +509,10 @@ def device_info(
and re-read directly from the device (e.g. after a config push). and re-read directly from the device (e.g. after a config push).
The cache is also automatically invalidated after POST /device/config. The cache is also automatically invalidated after POST /device/config.
""" """
if serial:
return _via_device_access(
lambda: _device_access().identify(_unit_address(port, baud, host, tcp_port), serial))
baud = 38400 if baud is None else baud
log.info("GET /device/info port=%s host=%s tcp_port=%d force=%s", port, host, tcp_port, force) log.info("GET /device/info port=%s host=%s tcp_port=%d force=%s", port, host, tcp_port, force)
cache = get_cache() cache = get_cache()
@@ -459,15 +551,20 @@ def device_info(
@app.post("/device/connect") @app.post("/device/connect")
def device_connect( def device_connect(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"), port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"), baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"), host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"), tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
) -> dict: ) -> dict:
""" """
Connect to the device and return identity. POST variant for terra-view Connect to the device and return identity. POST variant for terra-view
compatibility with the SLMM proxy pattern. compatibility with the SLMM proxy pattern.
""" """
return device_info(port=port, baud=baud, host=host, tcp_port=tcp_port) # force=True PRESERVES today's behaviour: the old call omitted `force`, so it
# received FastAPI's Query(False) object, which is truthy -- /device/connect
# has always bypassed the cache. Passing False here would quietly change that.
return device_info(port=port, baud=baud, host=host, tcp_port=tcp_port,
force=True, serial=serial)
@app.get("/device/events") @app.get("/device/events")
@@ -1099,10 +1196,11 @@ def device_config_project(
@app.get("/device/monitor/status") @app.get("/device/monitor/status")
def device_monitor_status( def device_monitor_status(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"), port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"), baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"), host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"), tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
force: bool = Query(False, description="Bypass cache and re-read from device"), force: bool = Query(False, description="Bypass cache and re-read from device"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
) -> dict: ) -> dict:
""" """
Read monitoring status from the device. Read monitoring status from the device.
@@ -1118,6 +1216,10 @@ def device_monitor_status(
**Caching**: status is cached for 30 seconds to reduce cellular polling overhead. **Caching**: status is cached for 30 seconds to reduce cellular polling overhead.
Pass *force=true* to bypass the cache for an immediate fresh read. Pass *force=true* to bypass the cache for an immediate fresh read.
""" """
if serial:
return _via_device_access(
lambda: _device_access().status(_unit_address(port, baud, host, tcp_port), serial))
baud = 38400 if baud is None else baud
cache = get_cache() cache = get_cache()
conn_key = SFMCache.make_conn_key(host, tcp_port, port, baud) conn_key = SFMCache.make_conn_key(host, tcp_port, port, baud)
@@ -1160,6 +1262,32 @@ def device_monitor_status(
return result return result
@app.get("/device/settings")
def device_settings(
serial: str = Query(..., description=_SERIAL_DOC),
port: Optional[str] = Query(None, description="Serial port (e.g. /dev/ttyACM0)"),
baud: Optional[int] = Query(None, description="Serial baud (default by series)"),
host: Optional[str] = Query(None, description="TCP host -- modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
"""The unit's recording settings, in the shared shape for either series."""
return _via_device_access(
lambda: _device_access().settings(_unit_address(port, baud, host, tcp_port), serial))
@app.post("/device/hangup")
def device_hangup(
port: Optional[str] = Query(None, description="Serial port"),
baud: Optional[int] = Query(None, description="Serial baud"),
host: Optional[str] = Query(None, description="TCP host -- modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
"""Hang up a held line now instead of waiting for the idle timeout.
`hung_up` is false if nothing was being held."""
return _via_device_access(
lambda: {"hung_up": _device_access().hang_up(_unit_address(port, baud, host, tcp_port))})
@app.get("/device/events/storage_range") @app.get("/device/events/storage_range")
def device_events_storage_range( def device_events_storage_range(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"), port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
+124
View File
@@ -0,0 +1,124 @@
"""Fakes of both device clients for sfm.device_access tests.
They return the libraries' real dataclasses, and FakeMicromateClient's setup
is decoded from a real UM20147 read. `fail` is a queue of exceptions; each
call pops one, if any, and raises it.
"""
from __future__ import annotations
import datetime
from pathlib import Path
from micromate.models import MicromateDeviceInfo, MicromateState
from micromate.setup_block import decode_setup
from minimateplus.models import ComplianceConfig, DeviceInfo, MonitorStatus
SETUP_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-setup" / "um20147_baseline.bin"
class _Base:
def __init__(self, fail=None, open_error=None):
self.fail = list(fail or [])
self.open_error = open_error
self.calls: list[str] = []
self.opened = 0
self.closed = 0
self._open = False
def _step(self, name):
self.calls.append(name)
if self.fail:
raise self.fail.pop(0)
def open(self):
self.opened += 1
if self.open_error is not None:
raise self.open_error
self._open = True
def close(self):
self.closed += 1
self._open = False
class FakeMiniMateClient(_Base):
def __init__(self, serial="BE18193", *, monitoring=False, compliance="default", **kw):
super().__init__(**kw)
self.serial = serial
self.monitoring = monitoring
if compliance == "default":
compliance = ComplianceConfig(
recording_mode=0x01, sample_rate=1024, histogram_interval_sec=300,
record_time=3.0, trigger_level_geo=0.5, alarm_level_geo=1.0, geo_range=0,
setup_name="BRIDGE-A", project="Bridge job", client="Acme",
operator="BH", sensor_location="Loc 1", notes=None,
)
self.compliance = compliance
def connect(self) -> DeviceInfo:
self._step("connect")
return DeviceInfo(
serial=self.serial, firmware_minor=17, firmware_version="S338.17",
dsp_version="10.72", manufacturer="Instantel", model="MiniMate Plus",
compliance_config=self.compliance,
)
def poll(self) -> None:
self._step("poll")
def get_monitor_status(self) -> MonitorStatus:
self._step("get_monitor_status")
return MonitorStatus(
is_monitoring=self.monitoring, battery_v=6.8,
memory_total=983026, memory_free=900000,
)
class _FakeProtocol:
def __init__(self, owner):
self._owner = owner
def poll(self):
self._owner._step("poll")
class FakeMicromateClient(_Base):
def __init__(self, serial="UM20147", *, monitoring=False, events=5,
unsolicited=b"", **kw):
super().__init__(**kw)
self.serial = serial
self.monitoring = monitoring
self.events = events
self.unsolicited = unsolicited
self.protocol = _FakeProtocol(self)
def is_open(self) -> bool:
return self._open
def connect(self) -> MicromateDeviceInfo:
self._step("connect")
return MicromateDeviceInfo(
serial=self.serial, manufacturer="Instantel", model="MM/ISEE/S",
firmware_line="thor", monitoring=self.monitoring, active_setup="test2.MMB",
)
def get_state(self) -> MicromateState:
self._step("get_state")
return MicromateState(
monitoring=self.monitoring,
device_time=datetime.datetime(2026, 10, 20, 18, 7, 58),
battery_volts=3.8, memory_total_bytes=15_000_000, memory_free_bytes=14_799_296,
)
def get_event_count(self) -> int:
self._step("get_event_count")
return self.events
def get_setup(self):
self._step("get_setup")
return decode_setup(SETUP_FIXTURE.read_bytes()[11:])
def read_unsolicited(self) -> bytes:
self._step("read_unsolicited")
data, self.unsolicited = self.unsolicited, b""
return data
+244
View File
@@ -0,0 +1,244 @@
"""DeviceAccess: dispatch by serial, sessions, the lock, the reaper -- and the
contract that both series answer in the same shape."""
from __future__ import annotations
import dataclasses
import os
import sys
import threading
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from device_access_fakes import FakeMiniMateClient, FakeMicromateClient # noqa: E402
from sfm.device_access.access import DeviceAccess # noqa: E402
import micromate.protocol as mm_proto # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
BadRequest, CallHomeInProgress, ConnectFailed, UnitBusy, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s4 import RingDetected # noqa: E402
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
class Clock:
def __init__(self, t=1000.0):
self.t = t
def __call__(self):
return self.t
def access(s3=(), s4=(), clock=None, lock_timeout=0.2):
s3q, s4q = list(s3), list(s4)
return DeviceAccess(
s3_client_factory=lambda a: s3q.pop(0),
s4_client_factory=lambda a: s4q.pop(0),
clock=clock or Clock(), lock_timeout=lock_timeout, start_reaper=False,
)
def test_the_serial_prefix_picks_the_adapter():
da = access(s3=[FakeMiniMateClient()], s4=[FakeMicromateClient()])
assert da.identify(ADDR, "be18193").series == 3
assert da.identify(ADDR, " um20147").series == 4
def test_an_unknown_prefix_never_touches_a_unit():
da = access()
with pytest.raises(BadRequest):
da.identify(ADDR, "XX123")
def test_a_micromate_stays_on_the_line_between_requests():
fake = FakeMicromateClient()
da = access(s4=[fake])
da.identify(ADDR, "UM20147")
da.status(ADDR, "UM20147")
da.settings(ADDR, "UM20147")
assert fake.opened == 1 # one call-up, three requests
assert fake.calls[0] == "connect"
def test_a_minimate_reconnects_per_request():
a, b = FakeMiniMateClient(), FakeMiniMateClient()
da = access(s3=[a, b])
da.status(ADDR, "BE18193")
da.status(ADDR, "BE18193")
assert a.closed == 1 and b.closed == 1
def test_a_dropped_line_is_called_up_again_quietly():
first, second = FakeMicromateClient(), FakeMicromateClient()
da = access(s4=[first, second])
da.status(ADDR, "UM20147")
first._open = False # the modem dropped the idle line
st = da.status(ADDR, "UM20147")
assert st.series == 4 and second.opened == 1
def test_a_different_serial_at_a_held_address_is_refused_without_io():
first, second = FakeMicromateClient(), FakeMicromateClient(serial="UM12947")
da = access(s4=[first, second])
da.status(ADDR, "UM20147")
with pytest.raises(WrongUnit, match="hangup"):
da.status(ADDR, "UM12947")
assert first.closed == 0 and second.opened == 0
assert da.held_serial(ADDR) == "UM20147"
def test_a_different_serial_replaces_a_session_that_is_no_longer_open():
first, second = FakeMicromateClient(), FakeMicromateClient(serial="UM12947")
da = access(s4=[first, second])
da.status(ADDR, "UM20147")
first.close()
da.status(ADDR, "UM12947")
assert second.opened == 1
def test_a_busy_unit_answers_423_without_a_second_connection():
fake = FakeMicromateClient()
da = access(s4=[fake], lock_timeout=0.2)
entered, release = threading.Event(), threading.Event()
def slow_request():
with da._locks.hold(ADDR.key): # simulate a request in flight
entered.set()
release.wait(2)
t = threading.Thread(target=slow_request)
t.start()
entered.wait(2)
try:
with pytest.raises(UnitBusy):
da.status(ADDR, "UM20147")
assert fake.opened == 0 # no second connection was opened
finally:
release.set()
t.join()
def test_hang_up_closes_a_held_line():
fake = FakeMicromateClient()
da = access(s4=[fake])
da.status(ADDR, "UM20147")
assert da.hang_up(ADDR) is True
assert fake.closed == 1
assert da.hang_up(ADDR) is False # nothing left to hang up
def test_a_peer_dropped_line_that_still_reads_open_is_retried_once():
first, second = FakeMicromateClient(), FakeMicromateClient()
da = access(s4=[first, second])
da.status(ADDR, "UM20147")
first.fail = [mm_proto.TimeoutError("quiet")] # _open untouched: looks open
st = da.status(ADDR, "UM20147")
assert st.series == 4 and first.closed == 1 and second.opened == 1
def test_a_failed_fresh_call_up_is_not_retried():
da = access(s4=[FakeMicromateClient(open_error=ConnectionRefusedError("no"))])
with pytest.raises(ConnectFailed):
da.status(ADDR, "UM20147") # a 2nd attempt would pop an empty queue
def test_a_ring_on_a_held_line_is_not_retried():
first, second = FakeMicromateClient(), FakeMicromateClient()
da = access(s4=[first, second])
da.status(ADDR, "UM20147")
first.fail = [RingDetected("RADIO RING")]
with pytest.raises(CallHomeInProgress):
da.status(ADDR, "UM20147")
assert second.opened == 0
def test_series3_beside_a_held_series4_line_is_refused_without_io():
micro, mini = FakeMicromateClient(), FakeMiniMateClient()
da = access(s3=[mini], s4=[micro])
da.status(ADDR, "UM20147")
with pytest.raises(WrongUnit):
da.status(ADDR, "BE18193")
assert mini.opened == 0 and micro.closed == 0 and micro.is_open()
# ── the reaper ────────────────────────────────────────────────────────────────
def test_tick_listens_then_keeps_alive_then_hangs_up_when_idle():
clock = Clock(1000.0)
fake = FakeMicromateClient()
da = access(s4=[fake], clock=clock)
da.status(ADDR, "UM20147")
fake.calls.clear()
clock.t = 1030.0
da.tick() # quiet: listen only
assert fake.calls == ["read_unsolicited"]
clock.t = 1061.0
da.tick() # 60 s since traffic: keep-alive
assert fake.calls[-1] == "poll"
clock.t = 1301.0
da.tick() # 300 s since last USE: hang up
assert fake.closed == 1
assert da.hang_up(ADDR) is False
def test_tick_releases_the_line_on_a_ring_while_idle():
clock = Clock(1000.0)
fake = FakeMicromateClient()
da = access(s4=[fake], clock=clock)
da.status(ADDR, "UM20147")
fake.fail = [RingDetected("RADIO RING")]
clock.t = 1010.0
da.tick()
assert fake.closed == 1
def test_tick_skips_a_unit_that_is_busy():
clock = Clock(1000.0)
fake = FakeMicromateClient()
da = access(s4=[fake], clock=clock)
da.status(ADDR, "UM20147")
fake.calls.clear()
clock.t = 1400.0
with da._locks.hold(ADDR.key):
da.tick() # must not block or hang up mid-request
assert fake.calls == [] and fake.closed == 0
def test_a_ring_mid_request_is_a_clear_error():
fake = FakeMicromateClient()
da = access(s4=[fake])
da.status(ADDR, "UM20147")
fake.fail = [RingDetected("RADIO RING")]
with pytest.raises(CallHomeInProgress):
da.status(ADDR, "UM20147")
# ── the contract: both series answer in the same shape ────────────────────────
@pytest.mark.parametrize("op", ["identify", "status", "settings"])
def test_both_series_return_the_same_model_with_the_same_fields(op):
da = access(s3=[FakeMiniMateClient()], s4=[FakeMicromateClient()])
s3 = getattr(da, op)(ADDR, "BE18193")
s4 = getattr(da, op)(ADDR, "UM20147")
assert type(s3) is type(s4)
assert [f.name for f in dataclasses.fields(s3)] == [f.name for f in dataclasses.fields(s4)]
assert (s3.series, s4.series) == (3, 4)
for name in (f.name for f in dataclasses.fields(s3)):
a, b = getattr(s3, name), getattr(s4, name)
if a is not None and b is not None and name != "detail":
assert type(a) is type(b) or {type(a), type(b)} <= {int, float}, name
def test_held_serial_reports_an_open_line_only():
fake = FakeMicromateClient()
da = access(s4=[fake])
assert da.held_serial(ADDR) is None
da.status(ADDR, "UM20147")
assert da.held_serial(ADDR) == "UM20147"
da.hang_up(ADDR)
assert da.held_serial(ADDR) is None
+138
View File
@@ -0,0 +1,138 @@
"""Core types of sfm.device_access: errors, series selection, models."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import micromate.protocol as mm_proto # noqa: E402
import minimateplus.protocol as mmp_proto # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
BadRequest, ConnectFailed, DeviceError, MalformedReply, NoAnswer, translate,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.series import normalise_serial, series_for_serial # noqa: E402
# ── series ────────────────────────────────────────────────────────────────────
@pytest.mark.parametrize(
"serial, series",
[("UM20147", 4), ("BE18193", 3), ("BA4521", 3), (" um20147 ", 4), ("be11529", 3)],
)
def test_the_prefix_picks_the_series(serial, series):
assert series_for_serial(serial) == series
def test_serials_are_normalised():
assert normalise_serial(" um20147\n") == "UM20147"
@pytest.mark.parametrize("serial", ["", "UM", "XX12345", "12345", "MP1234"])
def test_an_unknown_or_bare_prefix_is_a_bad_request(serial):
with pytest.raises(BadRequest, match="UM"):
series_for_serial(serial)
# ── errors ────────────────────────────────────────────────────────────────────
@pytest.mark.parametrize(
"exc, connecting, cls, status",
[
(mm_proto.TimeoutError("no frame"), False, NoAnswer, 504),
(mmp_proto.TimeoutError("no frame"), False, NoAnswer, 504),
(mm_proto.ChecksumError("bad"), False, MalformedReply, 502),
(mmp_proto.ProtocolError("bad"), False, MalformedReply, 502),
(ConnectionRefusedError("refused"), True, ConnectFailed, 503),
(OSError("reset"), False, ConnectFailed, 503),
],
)
def test_library_exceptions_translate_to_typed_errors(exc, connecting, cls, status):
out = translate(exc, connecting=connecting)
assert isinstance(out, cls)
assert out.http_status == status
def test_connect_and_mid_session_failures_read_differently():
assert "could not connect" in str(translate(OSError("x"), connecting=True))
assert "connection lost" in str(translate(OSError("x"), connecting=False))
def test_a_device_error_passes_through_unchanged():
e = NoAnswer("quiet")
assert translate(e, connecting=False) is e
def test_anything_else_becomes_a_plain_device_error():
out = translate(ValueError("boom"), connecting=False)
assert type(out) is DeviceError and out.http_status == 500
# ── models ────────────────────────────────────────────────────────────────────
def test_an_address_needs_a_host_or_a_port():
with pytest.raises(BadRequest):
UnitAddress(host=None, tcp_port=None, port=None, baud=None)
def test_the_lock_key_names_the_physical_link():
assert UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None).key == "tcp:10.0.0.5:9034"
assert UnitAddress(host=None, tcp_port=None, port="/dev/ttyACM0", baud=115200).key == "serial:/dev/ttyACM0"
# ── per-unit lock ─────────────────────────────────────────────────────────────
import threading # noqa: E402
from sfm.device_access.errors import UnitBusy # noqa: E402
from sfm.device_access.locks import UnitLocks # noqa: E402
def test_a_second_request_for_a_busy_unit_gets_unit_busy():
locks = UnitLocks(timeout=0.2)
entered = threading.Event()
release = threading.Event()
def holder():
with locks.hold("tcp:10.0.0.5:9034"):
entered.set()
release.wait(2)
t = threading.Thread(target=holder)
t.start()
entered.wait(2)
try:
with pytest.raises(UnitBusy, match="busy"):
with locks.hold("tcp:10.0.0.5:9034"):
pass
finally:
release.set()
t.join()
def test_different_units_do_not_block_each_other():
locks = UnitLocks(timeout=0.2)
with locks.hold("tcp:10.0.0.5:9034"):
with locks.hold("tcp:10.0.0.6:9034"):
pass
def test_try_hold_never_waits():
locks = UnitLocks(timeout=5)
with locks.hold("k"):
with locks.try_hold("k") as got:
assert got is False
with locks.try_hold("k") as got:
assert got is True
def test_the_lock_is_released_after_an_exception():
locks = UnitLocks(timeout=0.2)
with pytest.raises(RuntimeError):
with locks.hold("k"):
raise RuntimeError("boom")
with locks.hold("k"):
pass
+87
View File
@@ -0,0 +1,87 @@
"""The Series-3 adapter: connect-per-request, mapped into the shared models."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import minimateplus.protocol as mmp_proto # noqa: E402
from device_access_fakes import FakeMiniMateClient # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
ConnectFailed, MalformedReply, NoAnswer, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s3 import Series3Adapter # noqa: E402
TCP = UnitAddress(host="10.0.0.5", tcp_port=12345, port=None, baud=None)
SERIAL_LINK = UnitAddress(host=None, tcp_port=None, port="/dev/ttyUSB0", baud=None)
def adapter(*clients):
queue = list(clients)
return Series3Adapter(client_factory=lambda address: queue.pop(0))
def test_identify_maps_device_info():
fake = FakeMiniMateClient()
info = adapter(fake).identify(TCP, "BE18193")
assert (info.serial, info.series, info.model, info.firmware) == ("BE18193", 3, "MiniMate Plus", "S338.17")
assert info.active_setup == "BRIDGE-A"
assert info.monitoring is None # connect() does not read it on Series 3
assert fake.closed == 1
def test_a_different_unit_answering_is_refused():
fake = FakeMiniMateClient(serial="BE11529")
with pytest.raises(WrongUnit, match="BE18193.*BE11529"):
adapter(fake).identify(TCP, "BE18193")
assert fake.closed == 1
def test_status_maps_monitor_status():
fake = FakeMiniMateClient(monitoring=True)
st = adapter(fake).status(TCP, "BE18193")
assert (st.series, st.monitoring, st.battery_volts) == (3, True, 6.8)
assert (st.memory_total_bytes, st.memory_free_bytes) == (983026, 900000)
assert st.event_count is None and st.device_time is None
assert st.detail == {"serial_verified": False}
assert fake.calls == ["poll", "get_monitor_status"]
def test_settings_maps_the_compliance_config():
s = adapter(FakeMiniMateClient()).settings(TCP, "BE18193")
assert s.record_mode == "Continuous"
assert (s.sample_rate, s.record_time_s, s.histogram_interval_s) == (1024, 3.0, 300)
assert s.geo_trigger_ips == 0.5
assert s.setup_name == "BRIDGE-A"
assert s.notes == {"Project": "Bridge job", "Client": "Acme", "User Name": "BH", "Seis Loc": "Loc 1"}
assert s.detail["record_mode_code"] == 0x01
def test_settings_without_a_compliance_read_is_a_malformed_reply_and_not_retried():
# One fake only: a retry would ask the factory for a second and fail.
with pytest.raises(MalformedReply, match="settings"):
adapter(FakeMiniMateClient(compliance=None)).settings(TCP, "BE18193")
def test_a_cold_unit_over_tcp_gets_one_retry():
first = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("cold")])
second = FakeMiniMateClient()
info = adapter(first, second).identify(TCP, "BE18193")
assert info.serial == "BE18193"
assert first.closed == 1 and second.closed == 1
def test_a_serial_link_is_not_retried():
fake = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("quiet")])
with pytest.raises(NoAnswer):
adapter(fake).identify(SERIAL_LINK, "BE18193")
def test_a_failed_connect_is_connect_failed_and_not_retried():
fake = FakeMiniMateClient(open_error=ConnectionRefusedError("refused"))
with pytest.raises(ConnectFailed, match="could not connect"):
adapter(fake).identify(TCP, "BE18193")
+322
View File
@@ -0,0 +1,322 @@
"""Series-4 sessions: one call-up, then stay on the line; ring safety."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import micromate.protocol as mm_proto # noqa: E402
from device_access_fakes import FakeMicromateClient # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
CallHomeInProgress, ConnectFailed, NoAnswer, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s4 import ( # noqa: E402
RingDetected, RingWatchTransport, Series4Session,
)
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
class ScriptedInner:
"""A minimal real-interface transport: is_connected is a PROPERTY."""
def __init__(self, chunks):
self.chunks = list(chunks)
self.written = []
self._c = False
def connect(self):
self._c = True
def disconnect(self):
self._c = False
@property
def is_connected(self):
return self._c
def write(self, data):
self.written.append(data)
def read(self, n):
return self.chunks.pop(0) if self.chunks else b""
class Clock:
def __init__(self, t=1000.0):
self.t = t
def __call__(self):
return self.t
def session(*clients, clock=None):
queue = list(clients)
return Series4Session(ADDR, "UM20147", lambda address: queue.pop(0), clock=clock or Clock())
# ── RingWatchTransport ────────────────────────────────────────────────────────
def test_ordinary_bytes_pass_through():
t = RingWatchTransport(ScriptedInner([b"\x02abc\x03"]))
assert t.read(4096) == b"\x02abc\x03"
def test_a_ring_raises():
t = RingWatchTransport(ScriptedInner([b"\r\nRADIO RING\r\n"]))
with pytest.raises(RingDetected):
t.read(4096)
def test_a_ring_split_across_reads_still_raises():
t = RingWatchTransport(ScriptedInner([b"\r\nRADIO R", b"ING\r\n"]))
assert t.read(4096) == b"\r\nRADIO R"
with pytest.raises(RingDetected):
t.read(4096)
def _real_frame(payload_data: bytes, sub: int = 0xA4) -> bytes:
from micromate.framing import ETX, STX, checksum, stuff
payload = bytes([0x00, 0xC5, sub, 0x00, 0x00]) + payload_data
return bytes([STX]) + stuff(payload + bytes([checksum(payload)])) + bytes([ETX])
def test_a_ring_inside_a_frame_is_data_not_a_call_home():
# The 0x2C call-home config block's dial string is literally "RADIO RING".
wire = _real_frame(b"\x00" * 6 + b"RADIO RING" + b"\x00" * 4)
t = RingWatchTransport(ScriptedInner([wire]))
assert t.read(4096) == wire
def test_a_ring_inside_a_frame_split_across_reads_is_still_data():
wire = _real_frame(b"xxRADIO RINGyy")
cut = wire.index(b"RADIO R") + 7
t = RingWatchTransport(ScriptedInner([wire[:cut], wire[cut:]]))
assert t.read(4096) == wire[:cut]
assert t.read(4096) == wire[cut:]
def test_a_ring_between_frames_still_raises():
t = RingWatchTransport(ScriptedInner([_real_frame(b"abc") + b"\r\nRADIO RING\r\n"]))
with pytest.raises(RingDetected):
t.read(4096)
def test_a_ring_split_across_reads_after_a_frame_still_raises():
t = RingWatchTransport(ScriptedInner([_real_frame(b"abc") + b"\r\nRADIO R", b"ING\r\n"]))
t.read(4096)
with pytest.raises(RingDetected):
t.read(4096)
def test_a_ring_arriving_right_after_a_frame_ends_still_raises():
t = RingWatchTransport(ScriptedInner([_real_frame(b"abc"), b"RADIO RING"]))
t.read(4096)
with pytest.raises(RingDetected):
t.read(4096)
def test_an_escaped_etx_inside_a_frame_does_not_end_it():
# DLE ETX inside the payload is literal data; the ring after it is still inside.
wire = b"\x02" + b"ab\x10\x03RADIO RINGcd" + b"\x03"
t = RingWatchTransport(ScriptedInner([wire]))
assert t.read(4096) == wire
def test_a_ring_that_follows_a_frame_with_an_escaped_etx_still_raises():
wire = b"\x02" + b"ab\x10\x03cd" + b"\x03" + b"RADIO RING"
t = RingWatchTransport(ScriptedInner([wire]))
with pytest.raises(RingDetected):
t.read(4096)
def _real_chain_client(chunks):
from micromate.client import MicromateClient
inner = ScriptedInner(chunks)
return MicromateClient(RingWatchTransport(inner), recv_timeout=0.5), inner
def test_real_chain_a_response_carrying_a_ring_in_its_payload_succeeds():
client, _ = _real_chain_client([_real_frame(b"\x30" + b"\x00" * 8 + b"RADIO RING")])
client.open()
frame = client.protocol.poll()
assert b"RADIO RING" in frame.data
def test_real_chain_an_unsolicited_ring_before_the_response_hangs_up():
from types import SimpleNamespace
client, inner = _real_chain_client([b"\r\nRADIO RING\r\n", _real_frame(b"\x30" + b"\x00" * 8)])
# Only the identity read is stubbed; open/close/protocol/transport are the real chain.
client.connect = lambda: SimpleNamespace(serial="UM20147")
s = Series4Session(ADDR, "UM20147", lambda address: client, clock=Clock())
with pytest.raises(CallHomeInProgress):
s.run(lambda c: c.protocol.poll())
assert not s.is_open and not inner.is_connected
def test_the_wrapper_keeps_is_connected_a_property():
inner = ScriptedInner([])
t = RingWatchTransport(inner)
t.connect()
assert t.is_connected is True
# ── call-up ───────────────────────────────────────────────────────────────────
def test_call_up_verifies_the_serial_once():
fake = FakeMicromateClient()
s = session(fake)
s.run(lambda c: c.get_state())
s.run(lambda c: c.get_event_count())
assert fake.calls == ["connect", "get_state", "get_event_count"]
assert fake.opened == 1
def test_a_different_unit_answering_is_refused_and_closed():
fake = FakeMicromateClient(serial="UM12947")
s = session(fake)
with pytest.raises(WrongUnit, match="UM20147.*UM12947"):
s.run(lambda c: c.get_state())
assert fake.closed == 1 and not s.is_open
assert fake.calls == ["connect"] # nothing after the identity check
def test_a_failed_connect_is_connect_failed():
s = session(FakeMicromateClient(open_error=ConnectionRefusedError("no")))
with pytest.raises(ConnectFailed, match="could not connect"):
s.run(lambda c: c.get_state())
# ── ring safety ───────────────────────────────────────────────────────────────
def test_a_ring_during_a_request_releases_the_line():
fake = FakeMicromateClient()
s = session(fake)
s.call_up()
fake.fail = [RingDetected("RADIO RING")]
with pytest.raises(CallHomeInProgress, match="calling home"):
s.run(lambda c: c.get_state())
assert not s.is_open and fake.closed == 1
def test_listen_while_idle_releases_the_line_on_a_ring_and_sends_nothing():
fake = FakeMicromateClient()
s = session(fake)
s.call_up()
fake.fail = [RingDetected("RADIO RING")]
with pytest.raises(CallHomeInProgress):
s.listen()
assert not s.is_open
assert fake.calls == ["connect", "read_unsolicited"]
def test_the_next_request_after_a_ring_calls_up_fresh():
first, second = FakeMicromateClient(), FakeMicromateClient()
s = session(first, second)
s.call_up()
first.fail = [RingDetected("RADIO RING")]
with pytest.raises(CallHomeInProgress):
s.run(lambda c: c.get_state())
s.run(lambda c: c.get_state())
assert second.calls == ["connect", "get_state"]
# ── what counts as use ────────────────────────────────────────────────────────
def test_keepalive_and_listen_do_not_count_as_use():
clock = Clock(1000.0)
fake = FakeMicromateClient()
s = session(fake, clock=clock)
s.call_up()
clock.t = 1060.0
s.keepalive()
clock.t = 1065.0
s.listen()
assert s.last_used == 1000.0
assert s.last_traffic == 1060.0
assert fake.calls == ["connect", "poll", "read_unsolicited"]
def test_a_request_counts_as_use():
clock = Clock(1000.0)
s = session(FakeMicromateClient(), clock=clock)
s.call_up()
clock.t = 1100.0
s.run(lambda c: c.get_state())
assert s.last_used == 1100.0 and s.last_traffic == 1100.0
def test_a_failure_mid_request_hangs_up():
fake = FakeMicromateClient()
s = session(fake)
s.call_up()
fake.fail = [mm_proto.TimeoutError("quiet")]
with pytest.raises(NoAnswer):
s.run(lambda c: c.get_state())
assert not s.is_open
# ── operations ────────────────────────────────────────────────────────────────
from sfm.device_access.s4 import s4_identify, s4_settings, s4_status # noqa: E402
def test_s4_identify():
info = s4_identify(FakeMicromateClient(monitoring=True), "UM20147")
assert (info.serial, info.series, info.model, info.monitoring) == ("UM20147", 4, "MM/ISEE/S", True)
assert info.active_setup == "test2.MMB"
assert info.firmware is None and info.detail["firmware_line"] == "thor"
def test_s4_status_includes_the_cheap_event_count():
st = s4_status(FakeMicromateClient(events=5), "UM20147")
assert (st.series, st.monitoring, st.battery_volts, st.event_count) == (4, False, 3.8, 5)
assert (st.memory_total_bytes, st.memory_free_bytes) == (15_000_000, 14_799_296)
assert st.device_time == "2026-10-20T18:07:58"
def test_s4_settings_maps_the_decoded_setup():
s = s4_settings(FakeMicromateClient(), "UM20147")
assert (s.series, s.setup_name, s.record_mode) == (4, "test2.MMB", "Histogram Combo")
assert (s.sample_rate, s.record_time_s, s.histogram_interval_s) == (1024, 10.0, 2)
assert s.geo_trigger_ips == pytest.approx(0.5, abs=1e-6)
assert list(s.notes) == ["Location", "Client", "Company", "General Notes"]
assert s.detail["pretrigger_s"] == 1.0
assert s.detail["mic_type"] == "linear"
assert s.detail["mic_trigger_db"] == pytest.approx(131.0, abs=0.01)
assert s.detail["geo_trigger_ips_per_channel"] == pytest.approx([0.5, 0.5, 0.5], abs=1e-6)
def test_a_new_request_clears_frame_state_left_by_a_stray_stx():
# A stray STX on an idle line would otherwise hide the ring that answers the
# next request. MicromateProtocol resets its own parser at every request too.
t = RingWatchTransport(ScriptedInner([b"\x02stray", b"\r\nRADIO RING\r\n"]))
t.connect()
t.read(64)
t.write(b"x")
with pytest.raises(RingDetected):
t.read(64)
def test_is_open_survives_a_hang_up_between_its_two_reads():
# held_serial() calls is_open without the unit lock; a concurrent hang-up can
# clear _client between the None check and the method call.
class Racy(Series4Session):
_reads = 0
@property
def _client(self):
Racy._reads += 1
return object.__new__(type("C", (), {"is_open": lambda s: True})) if Racy._reads == 1 else None
@_client.setter
def _client(self, value):
pass
s = Racy(ADDR, "UM20147", client_factory=lambda a: None)
assert s.is_open in (True, False)
+41 -3
View File
@@ -121,6 +121,7 @@ class ScriptedTransport:
def disconnect(self) -> None: def disconnect(self) -> None:
self._connected = False self._connected = False
@property
def is_connected(self) -> bool: def is_connected(self) -> bool:
return self._connected return self._connected
@@ -408,7 +409,7 @@ def test_the_client_owns_the_transport():
mm, t = client([]) mm, t = client([])
assert not mm.is_open() assert not mm.is_open()
mm.open() mm.open()
assert mm.is_open() and t.is_connected() assert mm.is_open() and t.is_connected
mm.close() mm.close()
assert not mm.is_open() assert not mm.is_open()
@@ -417,9 +418,9 @@ def test_context_manager_opens_and_closes():
t = ScriptedTransport([frame(0xA4, POLL), frame(0xEA, SERIAL), t = ScriptedTransport([frame(0xA4, POLL), frame(0xEA, SERIAL),
frame(0xB6, STATE_IDLE), frame(0xBE, setup_response("x.mmb"))]) frame(0xB6, STATE_IDLE), frame(0xBE, setup_response("x.mmb"))])
with MicromateClient(t, recv_timeout=0.5) as mm: with MicromateClient(t, recv_timeout=0.5) as mm:
assert t.is_connected() assert t.is_connected
assert mm.connect().serial == "UM12947" assert mm.connect().serial == "UM12947"
assert not t.is_connected() assert not t.is_connected
# ── The Thor firmware line, on real bytes ───────────────────────────────────── # ── The Thor firmware line, on real bytes ─────────────────────────────────────
@@ -536,3 +537,40 @@ def test_get_setup_verify_false_returns_the_corrupt_read():
data[CONTENT + 5] = 0x05 data[CONTENT + 5] = 0x05
mm, _ = client([frame(0xE5, bytes(data))]) mm, _ = client([frame(0xE5, bytes(data))])
assert mm.get_setup(verify=False).record_mode == 0x05 assert mm.get_setup(verify=False).record_mode == 0x05
def test_is_open_works_on_a_real_transport():
"""`is_connected` is a PROPERTY on BaseTransport. is_open() used to call
it, which raised TypeError on every real transport -- hidden because the
test double defined it as a method."""
from minimateplus.transport import TcpTransport
mm = MicromateClient(TcpTransport("127.0.0.1", port=9)) # never connected
assert mm.is_open() is False
# ── get_event_count() / read_unsolicited() ────────────────────────────────────
# 0x06 response data captured from UM20147 (11.0BD) by Task 2, Step 1. The
# expected count is that session's independent chain-walk count.
SR_UM20147 = bytes.fromhex("2400000000000000000000000000050000000900000000000000000000000600000000000000000000000000000000")
SR_UM20147_CHAIN_WALK_COUNT = 5
def test_event_count_is_content_0_4_and_matches_the_chain_walk():
mm, t = client([frame(0xF9, SR_UM20147, flags=FLAGS_THOR)])
assert mm.get_event_count() == SR_UM20147_CHAIN_WALK_COUNT
assert [w[5] for w in t.written] == [0x06]
def test_a_truncated_storage_range_raises():
mm, _ = client([frame(0xF9, bytes(CONTENT) + b"\x00\x05", flags=FLAGS_THOR)])
with pytest.raises(ProtocolError, match="storage range"):
mm.get_event_count()
def test_read_unsolicited_sends_nothing_and_returns_what_arrived():
"""Used to spot RADIO RING on an idle session. It must never write."""
mm, t = client([b"\r\nRADIO RING\r\n"])
assert mm.read_unsolicited() == b"\r\nRADIO RING\r\n"
assert t.written == []
+1
View File
@@ -52,6 +52,7 @@ class ScriptedTransport:
def disconnect(self) -> None: def disconnect(self) -> None:
self._connected = False self._connected = False
@property
def is_connected(self) -> bool: def is_connected(self) -> bool:
return self._connected return self._connected
+159
View File
@@ -0,0 +1,159 @@
"""Handlers called directly -- every parameter passed explicitly, because
FastAPI Query() defaults are FieldInfo objects, not values."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from fastapi import HTTPException # noqa: E402
import sfm.server as srv # noqa: E402
from device_access_fakes import FakeMiniMateClient, FakeMicromateClient # noqa: E402
from sfm.device_access.access import DeviceAccess # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
BadRequest, CallHomeInProgress, ConnectFailed, MalformedReply, NoAnswer,
NotSupported, UnitBusy, WrongUnit,
)
TCP = dict(port=None, baud=None, host="10.0.0.5", tcp_port=9034)
@pytest.fixture
def da(monkeypatch):
s3q = [FakeMiniMateClient() for _ in range(5)]
s4q = [FakeMicromateClient() for _ in range(5)]
access = DeviceAccess(s3_client_factory=lambda a: s3q.pop(0),
s4_client_factory=lambda a: s4q.pop(0), start_reaper=False)
monkeypatch.setattr(srv, "_device_access_instance", access)
return access
def test_info_with_a_serial_returns_the_shared_model(da):
out = srv.device_info(force=False, serial="UM20147", **TCP)
assert out["series"] == 4 and out["serial"] == "UM20147"
assert set(out) == {"serial", "series", "model", "firmware", "monitoring", "active_setup", "detail"}
def test_connect_passes_the_serial_through(da):
out = srv.device_connect(serial="BE18193", **TCP)
assert out["series"] == 3
def test_status_and_settings_with_a_serial(da):
assert srv.device_monitor_status(force=False, serial="UM20147", **TCP)["event_count"] == 5
assert srv.device_settings(serial="UM20147", **TCP)["record_mode"] == "Histogram Combo"
def test_hangup(da):
srv.device_monitor_status(force=False, serial="UM20147", **TCP)
assert srv.device_hangup(**TCP) == {"hung_up": True}
@pytest.mark.parametrize(
"exc, status",
[(BadRequest("x"), 422), (NotSupported("x"), 501), (WrongUnit("x"), 409),
(UnitBusy("x"), 423), (ConnectFailed("x"), 503), (CallHomeInProgress("x"), 503),
(NoAnswer("x"), 504), (MalformedReply("x"), 502)],
)
def test_typed_errors_become_their_http_status(monkeypatch, exc, status):
class Raising:
def identify(self, address, serial):
raise exc
monkeypatch.setattr(srv, "_device_access_instance", Raising())
with pytest.raises(HTTPException) as ei:
srv.device_info(force=False, serial="UM20147", **TCP)
assert ei.value.status_code == status
def test_a_missing_address_is_a_422(da):
with pytest.raises(HTTPException) as ei:
srv.device_settings(serial="UM20147", port=None, baud=None, host=None, tcp_port=9034)
assert ei.value.status_code == 422
def test_without_a_serial_the_legacy_path_runs_unchanged(monkeypatch):
"""No serial: today's Series-3 code path, today's response shape.
DeviceAccess must not be touched."""
class Untouchable:
def __getattr__(self, name):
raise AssertionError("DeviceAccess used on the legacy path")
class Cache:
def get_device_info(self, key):
return {"serial": "BE18193", "firmware_version": "S338.17"}
monkeypatch.setattr(srv, "_device_access_instance", Untouchable())
monkeypatch.setattr(srv, "get_cache", lambda: Cache())
out = srv.device_info(force=False, serial=None, **TCP)
assert out == {"serial": "BE18193", "firmware_version": "S338.17", "_cached": True}
# ── the /device/* guard ───────────────────────────────────────────────────────
from sfm.device_access.models import UnitAddress # noqa: E402
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
Q_TCP = {"host": "10.0.0.5", "tcp_port": "9034"}
@pytest.mark.parametrize("path", ["/device/events/erase", "/device/monitor/stop", "/device/config"])
def test_guard_refuses_a_um_serial_on_unsupported_routes_with_501(path):
out = srv._device_guard(path, {"serial": "um20147", **Q_TCP})
assert out is not None and out[0] == 501 and path in out[1]
def test_guard_lets_a_series3_serial_through_on_legacy_routes():
assert srv._device_guard("/device/events/erase", {"serial": "BE18193", **Q_TCP}) is None
@pytest.mark.parametrize("path", ["/device/info", "/device/connect",
"/device/monitor/status", "/device/settings",
"/device/hangup"])
def test_guard_allows_um_serial_on_serial_aware_routes_and_hangup(path):
assert srv._device_guard(path, {"serial": "UM20147", **Q_TCP}) is None
def test_guard_refuses_serialless_requests_at_a_held_address_with_409(da):
da.status(ADDR, "UM20147")
out = srv._device_guard("/device/monitor/stop", dict(Q_TCP))
assert out is not None and out[0] == 409
assert "UM20147" in out[1] and "tcp:10.0.0.5:9034" in out[1] and "hangup" in out[1]
def test_guard_allows_serialless_requests_at_an_unheld_address(da):
assert srv._device_guard("/device/monitor/stop", dict(Q_TCP)) is None
assert srv._device_guard("/device/monitor/stop", {"host": "10.9.9.9"}) is None
def test_guard_ignores_non_device_paths(da):
assert srv._device_guard("/db/events", {"serial": "UM20147", **Q_TCP}) is None
def test_guard_allows_an_unbuildable_address_through(da):
assert srv._device_guard("/device/monitor/stop", {}) is None
@pytest.mark.parametrize("serial", ["BE18193", "BA1", "nonsense"])
def test_guard_refuses_any_non_um_serial_on_a_legacy_route_at_a_held_address(da, serial):
# FastAPI drops the undeclared serial, so the legacy Series-3 handler would run
# at the held Series-4 address -- the same hole as a serial-less request.
da.status(ADDR, "UM20147")
out = srv._device_guard("/device/events/erase", {"serial": serial, **Q_TCP})
assert out is not None and out[0] == 409 and "UM20147" in out[1]
def test_guard_leaves_serial_aware_routes_to_device_access_at_a_held_address(da):
# DeviceAccess routes by series and refuses a Series-3 serial beside a held line itself.
da.status(ADDR, "UM20147")
assert srv._device_guard("/device/info", {"serial": "BE18193", **Q_TCP}) is None
def test_guard_ignores_an_unparseable_baud_when_checking_for_a_held_line(da):
# baud is not part of the address key; pydantic would coerce "38400.0" and run the handler.
da.status(ADDR, "UM20147")
out = srv._device_guard("/device/monitor/stop", {"baud": "38400.0", **Q_TCP})
assert out is not None and out[0] == 409