Bug: timestamps not working properly. #43

Closed
opened 2026-10-24 12:40:07 -04:00 by serversdown · 2 comments
Owner

Issue moved from Terra-view repo to here. Original is at: serversdown/terra-view#116 (comment)

This event was from the 10-21-2026 blast at layton tunnel, approx time of blast was 12:37 PM, yet the timestamp shows 6:00:13?

(confirmed via BW ACH, actual time stamp should be 12:37:23. (BE 12844, n844LTF1.QB0W))

image.png

Issue moved from Terra-view repo to here. Original is at: https://gitea.serversdown.net/serversdown/terra-view/issues/116#issue-205 This event was from the 10-21-2026 blast at layton tunnel, approx time of blast was 12:37 PM, yet the timestamp shows 6:00:13? (confirmed via BW ACH, actual time stamp should be 12:37:23. (BE 12844, n844LTF1.QB0W)) ![image.png](/attachments/b6d071fc-41d8-4775-8931-7983d982514c)
serversdown added the Kind/Bug
Priority
Medium
3
Reviewed
Confirmed
1
labels 2026-10-24 12:40:58 -04:00
Author
Owner

Fixed on dev, ships in v0.32.0 (PR #54). Not auto-closed, because this exact event isn't on the dev box to verify.

The cause was that v0.31.0 stamped Series-3 waveforms with the monitoring-session start. On BE12844 that's 06:00:13, exactly the time this issue shows. v0.32.0 reads the trigger from the instrument's own event record, which the unit sends in its 5A stream (Series-III reference §7.8.9). On BE12844's seven oracle waveforms, which also showed 06:00:13, it gives Blastware's exact trigger times, and it matches Blastware's report on 1,320/1,320 waveforms overall.

Still to verify, after the deploy and its backfill (backfill_sidecars.py --force --reparse-txt, which corrects stored rows in place): check that N844LTF1.QB0W reads 12:37:23 in Terra-View, then close this.

**Fixed on `dev`, ships in v0.32.0 (PR #54).** Not auto-closed, because this exact event isn't on the dev box to verify. The cause was that v0.31.0 stamped Series-3 waveforms with the monitoring-session start. On BE12844 that's **06:00:13**, exactly the time this issue shows. v0.32.0 reads the trigger from the instrument's own event record, which the unit sends in its 5A stream (Series-III reference §7.8.9). On BE12844's seven oracle waveforms, which also showed 06:00:13, it gives Blastware's exact trigger times, and it matches Blastware's report on 1,320/1,320 waveforms overall. **Still to verify, after the deploy and its backfill** (`backfill_sidecars.py --force --reparse-txt`, which corrects stored rows in place): check that `N844LTF1.QB0W` reads **12:37:23** in Terra-View, then close this.
Author
Owner

FIxed

FIxed
Sign in to join this conversation.