@@ -0,0 +1,121 @@
"""Series-3 adapter. Connect-per-request, as SFM has always done for
MiniMates -- a held session waits for the bench test in the spec."""
from __future__ import annotations
import logging
from typing import Any, Callable
from minimateplus import MiniMateClient
from minimateplus.transport import TcpTransport
from .errors import DeviceError, MalformedReply, NoAnswer, WrongUnit, translate
from .models import UnitAddress, UnitInfo, UnitSettings, UnitStatus
log = logging.getLogger("sfm.device_access")
S3_DEFAULT_BAUD = 38400
S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"}
def default_s3_client_factory(address: UnitAddress, timeout: float = 10.0) -> MiniMateClient:
if address.host:
return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port), timeout=timeout)
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
class Series3Adapter:
def __init__(self, client_factory: Callable[[UnitAddress], Any] = default_s3_client_factory) -> None:
self._factory = client_factory
def _run(self, address: UnitAddress, fn: Callable[[Any], Any]) -> Any:
def attempt() -> Any:
client = self._factory(address)
try:
client.open()
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
try:
return fn(client)
except DeviceError:
raise
except Exception as exc:
raise translate(exc, connecting=False) from exc
finally:
_close(client)
try:
return attempt()
except NoAnswer:
# A MiniMate that has just had its serial lines asserted can take
# 5-10 s to boot, and shows it as silence; one retry covers it. TCP
# only -- on a serial cable a silence is a real fault. Narrower than
# server._run_with_retry (any protocol error): retrying a
# MalformedReply would also retry "no settings block", which a
# reconnect cannot fix.
if not address.host:
raise
log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key)
return attempt()
@staticmethod
def _check(serial_reported: str, serial: str, address: UnitAddress) -> None:
if (serial_reported or "").strip().upper() != serial:
raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}")
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
def op(client: Any) -> UnitInfo:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
return UnitInfo(
serial=info.serial, series=3, model=info.model, firmware=info.firmware_version,
monitoring=None, active_setup=cc.setup_name if cc else None,
detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version},
)
return self._run(address, op)
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
def op(client: Any) -> UnitStatus:
client.poll()
ms = client.get_monitor_status()
return UnitStatus(
serial=serial, series=3, monitoring=ms.is_monitoring,
battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None,
memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free,
device_time=None, event_count=None,
)
return self._run(address, op)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
def op(client: Any) -> UnitSettings:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
if cc is None:
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
mode = None
if cc.recording_mode is not None:
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
notes = {
label: value for label, value in (
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
) if value is not None
}
return UnitSettings(
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
notes=notes,
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
"geo_range": cc.geo_range},
)
return self._run(address, op)
+124
View File
@@ -0,0 +1,124 @@
"""Fakes of both device clients for sfm.device_access tests.
They return the libraries' real dataclasses, and FakeMicromateClient's setup
is decoded from a real UM20147 read. `fail` is a queue of exceptions; each
call pops one, if any, and raises it.
"""
from __future__ import annotations
import datetime
from pathlib import Path
from micromate.models import MicromateDeviceInfo, MicromateState
from micromate.setup_block import decode_setup
from minimateplus.models import ComplianceConfig, DeviceInfo, MonitorStatus
SETUP_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-setup" / "um20147_baseline.bin"
class _Base:
def __init__(self, fail=None, open_error=None):
self.fail = list(fail or [])
self.open_error = open_error
self.calls: list[str] = []
self.opened = 0
self.closed = 0
self._open = False
def _step(self, name):
self.calls.append(name)
if self.fail:
raise self.fail.pop(0)
def open(self):
self.opened += 1
if self.open_error is not None:
raise self.open_error
self._open = True
def close(self):
self.closed += 1
self._open = False
class FakeMiniMateClient(_Base):
def __init__(self, serial="BE18193", *, monitoring=False, compliance="default", **kw):
super().__init__(**kw)
self.serial = serial
self.monitoring = monitoring
if compliance == "default":
compliance = ComplianceConfig(
recording_mode=0x01, sample_rate=1024, histogram_interval_sec=300,
record_time=3.0, trigger_level_geo=0.5, alarm_level_geo=1.0, geo_range=0,
setup_name="BRIDGE-A", project="Bridge job", client="Acme",
operator="BH", sensor_location="Loc 1", notes=None,
)
self.compliance = compliance
def connect(self) -> DeviceInfo:
self._step("connect")
return DeviceInfo(
serial=self.serial, firmware_minor=17, firmware_version="S338.17",
dsp_version="10.72", manufacturer="Instantel", model="MiniMate Plus",
compliance_config=self.compliance,
)
def poll(self) -> None:
self._step("poll")
def get_monitor_status(self) -> MonitorStatus:
self._step("get_monitor_status")
return MonitorStatus(
is_monitoring=self.monitoring, battery_v=6.8,
memory_total=983026, memory_free=900000,
)
class _FakeProtocol:
def __init__(self, owner):
self._owner = owner
def poll(self):
self._owner._step("poll")
class FakeMicromateClient(_Base):
def __init__(self, serial="UM20147", *, monitoring=False, events=5,
unsolicited=b"", **kw):
super().__init__(**kw)
self.serial = serial
self.monitoring = monitoring
self.events = events
self.unsolicited = unsolicited
self.protocol = _FakeProtocol(self)
def is_open(self) -> bool:
return self._open
def connect(self) -> MicromateDeviceInfo:
self._step("connect")
return MicromateDeviceInfo(
serial=self.serial, manufacturer="Instantel", model="MM/ISEE/S",
firmware_line="thor", monitoring=self.monitoring, active_setup="test2.MMB",
)
def get_state(self) -> MicromateState:
self._step("get_state")
return MicromateState(
monitoring=self.monitoring,
device_time=datetime.datetime(2026, 10, 20, 18, 7, 58),
battery_volts=3.8, memory_total_bytes=15_000_000, memory_free_bytes=14_799_296,
)
def get_event_count(self) -> int:
self._step("get_event_count")
return self.events
def get_setup(self):
self._step("get_setup")
return decode_setup(SETUP_FIXTURE.read_bytes()[11:])
def read_unsolicited(self) -> bytes:
self._step("read_unsolicited")
data, self.unsolicited = self.unsolicited, b""
return data
+86
View File
@@ -0,0 +1,86 @@
"""The Series-3 adapter: connect-per-request, mapped into the shared models."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import minimateplus.protocol as mmp_proto # noqa: E402
from device_access_fakes import FakeMiniMateClient # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
ConnectFailed, MalformedReply, NoAnswer, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s3 import Series3Adapter # noqa: E402
TCP = UnitAddress(host="10.0.0.5", tcp_port=12345, port=None, baud=None)
SERIAL_LINK = UnitAddress(host=None, tcp_port=None, port="/dev/ttyUSB0", baud=None)
def adapter(*clients):
queue = list(clients)
return Series3Adapter(client_factory=lambda address: queue.pop(0))
def test_identify_maps_device_info():
fake = FakeMiniMateClient()
info = adapter(fake).identify(TCP, "BE18193")
assert (info.serial, info.series, info.model, info.firmware) == ("BE18193", 3, "MiniMate Plus", "S338.17")
assert info.active_setup == "BRIDGE-A"
assert info.monitoring is None # connect() does not read it on Series 3
assert fake.closed == 1
def test_a_different_unit_answering_is_refused():
fake = FakeMiniMateClient(serial="BE11529")
with pytest.raises(WrongUnit, match="BE18193.*BE11529"):
adapter(fake).identify(TCP, "BE18193")
assert fake.closed == 1
def test_status_maps_monitor_status():
fake = FakeMiniMateClient(monitoring=True)
st = adapter(fake).status(TCP, "BE18193")
assert (st.series, st.monitoring, st.battery_volts) == (3, True, 6.8)
assert (st.memory_total_bytes, st.memory_free_bytes) == (983026, 900000)
assert st.event_count is None and st.device_time is None
assert fake.calls == ["poll", "get_monitor_status"]
def test_settings_maps_the_compliance_config():
s = adapter(FakeMiniMateClient()).settings(TCP, "BE18193")
assert s.record_mode == "Continuous"
assert (s.sample_rate, s.record_time_s, s.histogram_interval_s) == (1024, 3.0, 300)
assert s.geo_trigger_ips == 0.5
assert s.setup_name == "BRIDGE-A"
assert s.notes == {"Project": "Bridge job", "Client": "Acme", "User Name": "BH", "Seis Loc": "Loc 1"}
assert s.detail["record_mode_code"] == 0x01
def test_settings_without_a_compliance_read_is_a_malformed_reply_and_not_retried():
# One fake only: a retry would ask the factory for a second and fail.
with pytest.raises(MalformedReply, match="settings"):
adapter(FakeMiniMateClient(compliance=None)).settings(TCP, "BE18193")
def test_a_cold_unit_over_tcp_gets_one_retry():
first = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("cold")])
second = FakeMiniMateClient()
info = adapter(first, second).identify(TCP, "BE18193")
assert info.serial == "BE18193"
assert first.closed == 1 and second.closed == 1
def test_a_serial_link_is_not_retried():
fake = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("quiet")])
with pytest.raises(NoAnswer):
adapter(fake).identify(SERIAL_LINK, "BE18193")
def test_a_failed_connect_is_connect_failed_and_not_retried():
fake = FakeMiniMateClient(open_error=ConnectionRefusedError("refused"))
with pytest.raises(ConnectFailed, match="could not connect"):