Blastware prints one Monitor Log line per event: the footer's start and
stop, then words for the footer's flag word [18:20] -- 69,983 / 69,983
DL2 lines, character for character (2026-11-08):
0x0001 Event Recorded 0x0010 Timer Stop
0x0002 Keyboard Exit 0x0020 Modem Exit
0x0004 Remote Exit 0x0200 Battery Low Exit
0x0008 Selfcheck Passed 0x0800 Memory Full Exit
One line sets Modem and Timer and prints Modem, so the higher bit wins
(the order of the others is inferred). Footer [20:22] is the event
record's trigger source again (69,983 / 69,983); [22:24] is zero; [24:26]
is not a common CRC-16 or sum.
Event.monitor_log: MonitorLogLine(start, stop, flags, description), read
only when the file's record chain is whole, which proves the footer.
The checker compares it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9