Files
seismo-relay/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md
T
serversdownandClaude Opus 5.5 1c6aa04687 docs(spec): SFM Series-4 parity and a device safety layer -- design for review
Parity of jobs with Series 3 for regular comms and settings (identify,
status, settings, events, download, monitor log, start/stop, call-home
enable/disable, setup push); Series-4 emergency tools deferred.  A single
device-access layer: series from the serial prefix, identity confirmed
before any write, a per-unit lock, an 0xA2 opcode guard, read-back
verification of every change, distinct error codes, and an audit table.
Series-4 sessions ("stay on the line") now; Series-3 sessions after a bench
test of MiniMate hangup/DCD behaviour.

Includes the fix list found in the 2026-10-19 inventory, the to-be-added
table, and the RX55 container idea as a parking-lot item.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 17:41:00 -04:00

17 KiB
Raw Blame History

SFM: Series-4 parity and a device safety layer — design

Date: 2026-10-20 · Branch: feat/series4-sfm-parity · Status: draft for review Decided with: Brian, in conversation 2026-10-19/20.

In plain terms

SFM can already read a Micromate almost as well as it reads a MiniMate, but only through the Python library and bench scripts. SFM's web endpoints still only speak Series 3. This design does three things:

  1. Gives Series 4 the same everyday jobs in SFM that Series 3 has: identify a unit, check its status, read its settings, list and download events, start/stop monitoring, and change its settings.
  2. Adds a safety layer every device request goes through. It makes sure a command only reaches the unit it was meant for, logs every change, and checks every change by reading the unit back.
  3. Lets SFM stay on the line with a Micromate. It calls up once, confirms the serial, and keeps the connection open for later commands instead of reconnecting each time.

It does not cover the emergency tools (runaway-unit stops, rescue, erase), the call-home receiver, or anything async. Those come later, as features shared by both series.

Production reach, stated honestly: while THOR is set to stay connected to production Micromates, a modem's single connection is taken. SFM can't reach those units until THOR lets go or SFM takes over call-home. In this phase, Series-4 SFM is for the bench and for units THOR is not holding.


Decisions

decision why who
Match jobs, not endpoints some Series-3 endpoints only exist to work around Series-3 quirks agreed
No Series-4 emergency tools yet (runaway stop, rescue, erase) Micromates rarely need them Brian
The series comes from the serial prefix: UM = Micromate, BE = MiniMate Plus, BA = Blastmate the prefixes are definitive, so there is no probing Brian
Before any write, confirm the unit that answered is the one named SFM addresses units by IP; a moved modem or stale IP means a different unit answers agreed
Synchronous endpoints for now; async later, for both series together parity first, then shared features agreed
No PC-side setup library a name is the only link between Thor's two copies, and nothing checks they match Brian
Sessions for Series 4 now; Series 3 only after a bench test THOR holds Micromate lines daily without harm; a MiniMate's hangup/DCD behaviour is untested Brian
Audit log in SFM's database (new table) Terra-View can show it; it fits the existing CREATE TABLE IF NOT EXISTS pattern proposed

Scope: the parity table

Rows 8 and 11 of the original inventory (runaway stops, rescue/erase) are out of scope by decision.

# job Series 3 in SFM today Series 4: protocol status Series 4 in this phase
1 Identify a unit /device/info (walks the whole chain, slow) implemented: connect() dispatch to the Micromate client
2 Quick status (monitoring, battery, memory, clock) monitor/status, storage_range, events/index implemented: get_state(); the 0x06 event count is decoded only in the bench tool same endpoints; move the count decode into the client
3 Read settings compliance in /device/info; GET /device/call_home get_setup() implemented and verified on hardware; call-home: enable + dial string observed, rest unmapped setup in full; call-home returns enable + dial string + raw
4 List events /device/events (downloads every event to list them) implemented, and cheap: the chain walk returns sizes dispatch
5 Download an event /event/{i}, /waveform, /blastware_file implemented: streams the .IDFW/.IDFH itself, with a decode self-check save through the existing /db/import/idf_file path
6 Monitor log only via ach_server (broken, see the fix list) 0x0A read exists; no wrapper or decoder client wrapper + partial decode
7 Start / stop monitoring monitor/start, monitor/stop mapped, identical to Series 3 (0x96/0x97, acks 0x69/0x68); never sent first write. Verify with 0x49 state
9 Change call-home settings POST /device/call_home write mapped (0x2C → 0x7E/0x7F, same as Series 3); field map mostly unknown enable/disable only; the rest waits for the THOR round
10 Change recording settings POST /device/config sequence mapped (0xDA → 0x68/73 → 0x82/83 → 0x71/72); no encoder read-modify-write, stop → push → restart, verify with get_setup()

Architecture

One door for every device request

A new module, sfm/device_access.py, sits between the /device/* handlers and the two device libraries. No handler opens a transport or picks a library itself any more.

/device/* handler
      │  (serial, address, action, tier)
      ▼
device_access ── series from serial prefix ── session / per-unit lock
      │              │                               │
      │              ▼                               ▼
      │      minimateplus (S3)  or  micromate (S4)   audit table
      ▼
read-back verification (changes only)
  • Series selection. serial picks the library: UM → micromate; BE or BA → minimateplus; any other prefix → 422. With no serial, the request is Series 3, so existing Series-3 callers are unchanged. Series-4 requests must include serial.
  • Endpoints. The same /device/* paths, plus a serial query parameter. Responses gain "series": 3 | 4. Where the two series genuinely differ (the setup fields, the event identity), the body is series-specific under a documented shape rather than forced into Series 3's.
  • Work separate from HTTP. Each operation is a plain function taking the session. The handler is a thin wrapper, so making an operation an async job later means changing the wrapper, not the operation.

The safety layer

Tiers. Every operation declares one:

tier examples what the layer does
read info, status, setup, events, download runs; no identity check
change start/stop, call-home, setup push identity check → audit → send → read back → audit the result
destructive delete, erase (none in this phase) everything above + the caller must send the unit's serial as confirm

Identity check (changes only). Before the first change in a connection, compare the serial the unit reports with the one requested; on a mismatch, refuse (409) and send nothing. Series 4 already reads the serial in connect(). A Series-3 change adds one serial read (SUB 0x15), about one round trip.

Opcode guard. A send-side check that refuses known cross-series collisions. It starts with 0xA2, which is CONFIRM ERASE on Series 3 and "end call-home" on Series 4. This phase never sends 0xA2; the guard makes that impossible by accident. The table of colliding opcodes lives in one place.

One connection per unit. A per-unit lock keyed by address (tcp:host:port / serial:port). A request for a busy unit waits up to 20 s (configurable; under Terra-View's 60 s proxy timeout), then gets 423 "unit busy" instead of opening a second connection. This applies to Series 3 as well. The webapp's Diagnostics refresh currently fires three device requests at once against a modem that allows one; under the lock they queue.

Read-back verification. A zero-data ack has never been proof that a write applied. Every change is followed by a read:

  • start/stop → 0x49 state: start expects 0x02, stop expects 0x00. Record the value either way; 0x03 is the in-call-home state
  • call-home → re-read 0x2C and compare the edited bytes
  • setup push → get_setup() and compare every field that was set

A mismatch is reported as a failed change (and audited as one), even if the ack was clean.

Errors that say what happened. Distinct responses for:

  • 503: couldn't connect
  • 504: connected but the unit didn't answer
  • 423: unit busy
  • 409: wrong unit
  • 422: bad input
  • 502: the reply was malformed

Today 502 covers both of the first two.

Audit table. New table device_commands, created on startup like the others. It is additive, but still a schema change, so the changelog says so. One row per change attempt:

column content
ts, serial, series, address who and where
action, tier e.g. monitor_stop, change
request parameters, plus hex of what was sent
ack reply summary
verified read-back result: ok / mismatch / not_checked
outcome, error final result
caller best-effort origin (webapp, terra-view, script)

Reads are not audited.

Sessions (Series 4)

  1. Call up. Connect, connect() (POLL / SERIAL / STATE), identity check against the requested serial.
  2. On the line. Requests for that unit run in turn on the same connection, behind the per-unit lock.
  3. Keep-alive. A POLL every 60 s while idle. The ACEmanager TCP idle timeout is 2 min.
  4. Hang up. On POST /device/hangup, after 5 idle minutes, or on any transport error. A reconnect is a new session with a new identity check.
  5. Ring safety. If RADIO RING arrives on an SFM session, log it and hang up immediately. Until SFM is the call-home destination, the unit's retry should reach THOR. 🔶 Inferred: the unit retries; its 0x2C retries field reads 3.

Series 3 keeps today's connect-per-request behaviour until the bench test under Testing.

Series-4 write path

Encoder. Extend micromate/framing.py:

  • a request builder that carries a data section
  • the same escape set {02,03,04,10}, applied to data, params and checksum
  • plain SUM8 of the destuffed payload (not Series 3's write format)

Rules: micromate_protocol_reference.md → The escape set — exactly four bytes, Checksum — plain SUM8 of the de-stuffed payload, Write-frame destuffing.

Dry run. Every Series-4 write accepts dry_run=true. It returns the exact frames it would send and sends nothing. The first live send of each write is reviewed this way first.

Per operation:

operation frames verify open questions it settles
start / stop 0x96 / 0x97, offset 0xFFFF, zero params 0x49 the ack when already in that state
call-home enable/disable read 0x2C → 0x7E (126 B content, offset 0x007E) → 0x7F re-read 0x2C none new; bit 0 of write[5]
setup push read 0x08, 0x2E, 0x1A → 0xDA (name) → 0x68/0x73 → 0x82/0x83 → 0x71/0x72 get_setup() the offset rule; whether 0x68/0x82 are needed

Setup push, details:

  • Read-modify-write of all three blocks, as THOR appears to do. 🔶 Inferred from two captures: 0x68 = the preferences content with [0:3] zeroed; 0x82 = the 0x2E content with [0:3] and the CRC slot zeroed; 0x71 = the 0x1A content [0:2090] with the length echo zeroed.
  • Offsets come from THOR's observed constants. 🔶 The hypothesis "offset = the read block's length + 2" fits all four, but each has been seen at one size only.
  • The edited fields come from MicromateSetup and are written back at the offsets setup_block.py already uses. Only fields graded measured may be edited.
  • Sequence: stop monitoring (if running) → push → restart (if it was running) → verify. THOR's "must be idle" is policy, not the device, but stopping first removes a variable from the first live write.
  • ⚠ Edit-buffer hazard. 0x1A reads the keypad's unsaved edits, so a read-modify-write taken while someone is in the menu would commit them. This can't be detected from the wire; it is documented in the endpoint and audited.
  • Target file: the active setup, overwritten in place, by default. A named target is allowed, but overwriting a non-active setup or factory.MMB is untested, so it is refused in this phase.

Testing

Offline (CI-capable):

  • Frame reproduction. The new encoder must reproduce THOR's captured write frames byte for byte: 0x96/0x97, 0x7E/0x7F, and the full setup push, from the 9-24 / 9-25 / 10-14 captures. This is the same method that proved the reads (218/218). The needed frames are copied into force-added fixtures, since bridges/captures/ is gitignored.
  • Safety layer on fakes:
    • series by prefix
    • identity mismatch → 409, nothing sent
    • 0xA2 refused
    • lock → 423
    • read-back mismatch → failed change
    • audit row written for every change attempt
    • RADIO RING → session ends
  • Endpoints through FastAPI's TestClient against the scripted transport already used in tests/test_micromate_client.py.

Bench (UM20147, with Brian): each write's first live send follows the same protocol:

  1. Dry run.
  2. Review the frames.
  3. Send once, with a capture running.
  4. Read back.
  5. Write the result into the reference.

Order: stop/start → call-home off/on → setup push of one field → setup push of several fields.

Series-3 session test (before Series-3 sessions are built): hold a call-up session open to a MiniMate that is monitoring, for several minutes. Record:

  • does it keep monitoring (does an event still record)?
  • after hangup, is it monitoring?
  • does it behave differently on an RV55 with the DCD issue?

Build phases

Each safety piece arrives with its first real use, so nothing sits untested.

  1. Series-4 reads in SFM. device_access.py, series selection, the per-unit lock (Series 3 too), the error mapping, and Series-4 sessions with ring safety. Rows 1–6. No writes.
  2. Encoder + opcode guard + dry run + frame-reproduction tests. Still nothing sent.
  3. Start/stop monitoring (row 7): the first live write, at the bench. Brings the identity check, the audit table and the read-back framework.
  4. Call-home enable/disable (row 9).
  5. Setup push (row 10): one field first, then several.

Each phase is its own implementation plan and its own merge.


Out of scope (this phase)

  • Series-4 emergency tools: runaway stops, rescue, per-event delete, erase. (Erase-all is also unmapped.)
  • Async jobs; auth (Terra-View as jump host); the call-home receiver. These are shared features for later.
  • Scheduler read/write/enable; clock set; remote sensor check; restart; firmware.
  • Series-3 sessions, pending the bench test.
  • Mapping the rest of 0x2C (the THOR round).

Fix list (found 2026-10-19, separate small changes)

  • bridges/ach_server.py:524: seen_keys is undefined. Series-3 call-home monitor-log collection has failed every session since 9afa348 (2026-05-07).
  • bridges/mm_ach_server.py:262: _cstring/_content aren't imported, so the ring-answer path would raise NameError. From 8f67608 (2026-10-14).
  • Series-3 5A 64 KB page-boundary bug (known; surfaces as HTTP 500).
  • POST /device/config writes a fixed 29-byte 0x82 blob from one 3-11-26 capture, whatever the unit's trigger settings.
  • /device/events runs a full 5A download per event just to list headers.
  • 0x08 is named read_event_index in micromate/; it is the preferences block.

Table 2: to be added later (both series)

area item
infrastructure async jobs; auth via Terra-View
THOR has it, SFM doesn't clock set; remote sensor check; scheduler; one setup to many units; restart
call-home receiver hold lines open (S4); "already downloaded" tracking; rules by serial prefix (copy events, monitor log, delete, set clock); detect "Monitor While Calling Home" blocking deletes (⚠ one unexplained 21 → 5 count drop in THOR's log); hand off to /db/import/* instead of the watchers
settings, the no-PC-files way intended settings per deployment; drift report (intended vs actual); push then verify
notifications email/SMS by event type and PPV (THOR does it; may belong in Terra-View)
emergency tools for S4 if a Micromate ever needs them

Parking lot

A modem-side agent on the RX55. AirLink OS on the RX55 has "Container Applications (Early Adopter)", and Brian already runs slmm-proxy there. A small program owning the unit's serial port could:

  • let THOR and SFM share the line
  • dial out to SFM, avoiding the IP whitelist
  • handle RADIO RING locally
  • Brian's hunch: make RX55s work with Series 3 by driving DTR/DCD itself

Open questions:

  • Can a container open the RS-232 port?
  • Can it set the control lines?
  • How is it deployed to a fleet, and does it Autostart?
  • Will a firmware update keep the beta feature?

Open questions this design leaves for the bench

  • The ack for start/stop when the unit is already in that state.
  • The offset rule, and whether 0x68/0x82 are required, for the setup push.
  • Whether the device ever refuses a write while monitoring. Only THOR's policy has been seen.
  • How a failed write is signalled. It has never been observed.
  • MiniMate behaviour with a held session (above).