serversdownandClaude Opus 5.5 5326e99ac2 fix(sfm): a monitoring MiniMate's call-home says 'stop monitoring first', not 'unknown(0x6E)'
Measured at the bench 2026-11-03 (BE9441): while monitoring, a MiniMate answers
the 0x2C call-home read with its DEVICE-INFO block ('Instantel', 'MiniMate Plus',
its serial) -- as it answers 1A -- and idle again, minutes later, the call-home
block.  SFM writes back only a block it just read, so a monitoring MiniMate's
call-home cannot be changed; the change core already refused (byte 5 read as
'unknown(0x6E)', nothing sent), but said so cryptically.

- minimateplus.protocol.is_call_home_block(raw): the block starts with its own
  length 0x7C and is N (or N + 2) bytes unescaped; the device-info block fails it.
- The Series-3 change raises UnitStateUnknown (409) with 'did not return its
  call-home settings -- a MiniMate answers the call-home read with its
  device-info block while monitoring; stop monitoring first ... nothing sent',
  for a dry run too.  call_home_state returns enabled = None with that reason.
- The page's callHomeRows shows the reason in place of 'Unknown (byte 5 = ...)'.

A blind write while monitoring stays untested on purpose.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 14:19:19 -05:00

525 lines
27 KiB
Python

"""Series-3 adapter. Connect-per-request, as SFM has always done for
MiniMates -- a held session waits for the bench test in the spec."""
from __future__ import annotations
import datetime
import logging
import struct
from typing import Any, Callable, Optional
from minimateplus import MiniMateClient
from minimateplus.blastware_file import blastware_file_bytes, blastware_filename, with_type_letter
from minimateplus.event_file_io import _GEO_INT16_FS
from minimateplus.framing import build_bw_write_frame, unescape_reply
from minimateplus.protocol import (
SUB_CALL_HOME_CONFIRM, SUB_CALL_HOME_WRITE, SUB_START_MONITORING, SUB_STOP_MONITORING,
ImageRefused, call_home_enabled, call_home_image, is_call_home_block, write_image,
)
from minimateplus.transport import TcpTransport
from .errors import (DeviceError, EventNotFound, MalformedReply, NoAnswer, NotSupported, StaleEvent,
UnitStateUnknown, WrongUnit, translate)
from .change import call_home_change, monitoring_change, run_change
from .events import iso_of, make_event_id, stamp_of
from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress,
UnitInfo, UnitSettings, UnitStatus)
log = logging.getLogger("sfm.device_access")
S3_DEFAULT_BAUD = 38400
S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"}
S3_EVENT_TIMEOUT = 120.0 # what the legacy event-download routes use
# A MiniMate call-home write goes out only once SFM's 0x7E / 0x7F frames are
# reproduced from Blastware's own; shut, a live change is refused before any
# connection (a dry run still works). OPEN since 2026-11-02:
# tests/test_s3_call_home_bw_frames.py rebuilds Blastware's enable and disable
# writes (BE11529, 2026-04-20) byte for byte from the unit's own reads.
S3_CALL_HOME_FRAME_VERIFIED = True
# Measured 2026-11-03 (BE9441): while monitoring, a MiniMate answers the 0x2C read
# with its device-info block, as it answers 1A -- its call-home settings cannot be
# read, so they cannot be changed (SFM writes back only a block it just read).
S3_CALL_HOME_WHILE_MONITORING = ("did not return its call-home settings -- a MiniMate answers the "
"call-home read with its device-info block while monitoring; "
"stop monitoring first, then change call-home")
# The 0x1C flag byte (section[1]): the only values ever measured. 0x10 is
# BE11529 monitoring (2026-04-08); 0x0B is BE9441 recording a histogram,
# confirmed at the unit (2026-10-26). Anything else is refused for a change.
S3_RUN_STATES = {0x00: "idle", 0x10: "monitoring", 0x0B: "monitoring"}
def s3_run_state(status: Any) -> str:
"""The change path's state name from the raw 0x1C flag -- never
`is_monitoring`, which reads every byte but 0x10 as idle. A value never
measured is `unknown(0x..)`, and the change core refuses it."""
flag = getattr(status, "state_flag", None)
if flag is None:
return "unknown(short)"
return S3_RUN_STATES.get(flag, f"unknown(0x{flag:02X})")
# A start makes the unit run its sensor check before "Recording..." -- ~30 s
# (Brian, 2026-10-26), ~40 s on BE11529 (2026-04-08). A start's read-back waits
# this long before asking, then wakes the unit with retries (S3_WAKE_*).
S3_SENSOR_CHECK_S = 30.0
S3_WAKE_ATTEMPT_S = 5.0
S3_WAKE_DEADLINE_S = 60.0
def _woken_state(client: Any) -> str:
"""The run state, read after waking the unit: SESSION_RESET + POLL first,
re-sent until it answers.
A monitoring MiniMate ignores a bare request until it is woken (measured
2026-04-08). On 2026-10-26 BE9441 acked a start, then left a bare 0x1C, and
later a single SESSION_RESET + POLL, unanswered for 120 s: both went out 2 s
after the start, inside the sensor check, and were never re-sent."""
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
return s3_run_state(client.get_monitor_status())
def default_s3_client_factory(address: UnitAddress, timeout: Optional[float] = None) -> MiniMateClient:
if address.host:
return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port),
timeout=10.0 if timeout is None else timeout)
if timeout is None:
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD)
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD, timeout=timeout)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
def _s3_dt(ev: Any) -> Optional[datetime.datetime]:
ts = getattr(ev, "timestamp", None)
if ts is None or ts.hour is None:
return None
try:
return datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
except (TypeError, ValueError):
return None
def _s3_filename(ev: Any, serial: str) -> Optional[str]:
try:
return blastware_filename(ev, serial)
except Exception: # noqa: BLE001
return None
S3_RECORD_TYPE_NOTE = "Series 3's event record does not say waveform or histogram; not decoded yet"
def _s3_ref(ev: Any, serial: str) -> EventRef:
"""record_type is always None: minimateplus's 0C decode reports "Waveform"
for every record layout, histograms included, so it cannot be trusted
here. Null rather than wrong until a histogram's 0C is captured."""
dt = _s3_dt(ev)
pv = ev.peak_values
peaks = {}
if pv is not None:
peaks = {k: v for k, v in (("tran", pv.tran), ("vert", pv.vert), ("long", pv.long))
if v is not None}
return EventRef(
event_id=make_event_id(serial, ev._waveform_key, stamp_of(dt)),
serial=serial, series=3, index=ev.index, timestamp=iso_of(dt),
record_type=None,
peak_vector_sum_ips=pv.peak_vector_sum if pv is not None else None,
peaks_ips=peaks, filename=_s3_filename(ev, serial),
detail={"mic_psi": pv.micl if pv is not None else None,
"record_type_note": S3_RECORD_TYPE_NOTE},
)
_GEO_FULL_SCALE_IPS = 10.0 # normal range; one decoder step = 0.005 in/s
_PEAK_TOLERANCE_IPS = 0.0051 # one 0.005 in/s step, plus the 0C's float32 slop
def verify_s3_download(ev: Any, compliance: Any, body: Optional[bytes] = None) -> tuple:
"""Check a downloaded event against itself and the unit's own 0C record: (verified, why).
A short or misassembled event must not reach the store -- BE9441's bench
(2026-10-25) stored two as successes before this existed. `body` is the
event's 5A body (taken from `ev._a5_frames` when not given). In order:
* No waveform decode: it must decode as a histogram (stored unverified --
its peaks are not compared yet), or it is refused. 0 of ~430 fixture
histograms decode as a waveform; a corrupted waveform decodes as neither.
* A waveform's record chain must end on its END record (0x06), as the
file reader requires; a cut-short stream does not.
* All three geophone channels must be the same length.
* Each channel's peak must be the unit's own to one 0.005 in/s step (a
clipped blast -- both at full scale -- counts as a match). Only for a
unit confirmed in normal range: a sensitive-range unit's scale is still
open (the 8x discrepancy), and an unread range is not assumed.
Raises MalformedReply ("not saved") on any failure.
"""
from minimateplus.blastware_file import extract_body_bytes
from minimateplus.histogram_codec import decode_histogram_body
from minimateplus.waveform_codec import STREAM_END_ID, walk_records
if body is None:
frames = getattr(ev, "_a5_frames", None)
body = extract_body_bytes(frames)[1] if frames else b""
samples = getattr(ev, "raw_samples", None) or {}
chans = ("Tran", "Vert", "Long")
if not all(samples.get(c) for c in chans):
if body and decode_histogram_body(body):
return None, "a histogram: stored unverified (its peaks are not compared yet)"
raise MalformedReply(
"the downloaded event decodes as neither a waveform nor a histogram -- the "
"download is incomplete or misassembled; not saved")
try:
recs = walk_records(body)
except Exception: # noqa: BLE001 -- treated as no chain
recs = []
tail = recs[-1]["end"] if recs else None
if tail is None or tail + 5 > len(body) or body[tail + 4] != STREAM_END_ID:
raise MalformedReply(
"the downloaded waveform's record chain has no end record -- the download is "
"cut short; not saved")
lengths = {c: len(samples[c]) for c in chans}
if len(set(lengths.values())) != 1:
raise MalformedReply(
f"the downloaded waveform's channels have different lengths {lengths} -- the "
"download is incomplete or misassembled; not saved")
if getattr(compliance, "geo_range", None) != 0:
return None, ("whole, but peaks not checked: the unit is not confirmed in normal "
"range (a sensitive-range scale is not settled)")
pv = ev.peak_values
unit = {"Tran": pv.tran, "Vert": pv.vert, "Long": pv.long} if pv else {}
clip = _GEO_FULL_SCALE_IPS - _PEAK_TOLERANCE_IPS
for c in chans:
if unit.get(c) is None:
return None, f"whole, but the unit's record gives no {c} peak to check against"
decoded = max(abs(x) for x in samples[c]) * _GEO_FULL_SCALE_IPS / _GEO_INT16_FS
if decoded >= clip and unit[c] >= clip:
continue # both at full scale: a clipped blast
if abs(decoded - unit[c]) > _PEAK_TOLERANCE_IPS:
raise MalformedReply(
f"the downloaded {c} peak is {decoded:.4f} in/s but the unit's own record says "
f"{unit[c]:.4f} -- the download is incomplete or misassembled; not saved")
return True, f"{lengths['Tran']} samples per channel, peaks match the unit's own"
class Series3Adapter:
def __init__(self, client_factory: Callable[..., Any] = default_s3_client_factory) -> None:
self._factory = client_factory
def change_monitoring(self, address: UnitAddress, serial: str, *, start: bool, dry_run: bool,
even_if_already: bool, audit: Any, caller: str,
sleep: Callable[[float], None], verify_timeout_s: float,
verify_interval_s: float) -> ChangeResult:
"""Series-3 pieces for the shared core in change.py. One attempt, never
retried: `retry=False` stops _run's cold-boot second attempt, and the
core calls the write once."""
sub = SUB_START_MONITORING if start else SUB_STOP_MONITORING
ack_sub = 0xFF - sub
def op(client: Any) -> ChangeResult:
def read_serial() -> str:
info = client.connect() # a fresh connection: connect() is the fresh 0x15 read
return info.serial or ""
def describe_plan() -> dict:
what = "start monitoring" if start else "stop monitoring"
return {"action": what, "sends_nothing": True, "warnings": [],
"steps": [{"sub": f"0x{sub:02X}", "what": what, "offset": "0x0000",
"data_len": 0, "expect_ack": f"0x{ack_sub:02X}",
"frame": build_bw_write_frame(sub, b"").hex()}]}
settle: list = []
def send() -> dict:
# The client validates the ack SUB; it returns nothing else, so none is claimed.
(client.start_monitoring if start else client.stop_monitoring)()
if start:
settle.append(S3_SENSOR_CHECK_S) # the first read waits out the check
return {"subs": [f"0x{ack_sub:02X}"]}
reconnected: list = []
def read_state() -> str:
if settle:
sleep(settle.pop())
try:
return _woken_state(client)
except OSError as exc:
# The modem can drop the line while the unit sensor-checks
# after a start: BE9441's first wake hit "[Errno 32] Broken
# pipe" (2026-10-29), and a fresh connection read it as
# monitoring. Reconnect once, TCP only (opening a MiniMate's
# serial port reboots it), check it is still the same unit,
# and read. A read -- nothing is re-sent.
if reconnected or not address.host:
raise
reconnected.append(True)
log.warning("Series 3 at %s: the line dropped during the read-back (%s) -- "
"reconnecting to read the state; nothing is re-sent",
address.key, exc)
client.close()
client.open()
# Wake first: the identity read is a bare 0x15, which a unit that
# has just started ignores until SESSION_RESET + POLL (the order
# the status read and the legacy write routes use: poll, then read).
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
self._check(client.read_serial(), serial, address)
return s3_run_state(client.get_monitor_status())
return run_change(
kind=monitoring_change(start), serial=serial, series=3, dry_run=dry_run,
even_if_already=even_if_already, audit=audit, address=address, caller=caller,
sleep=sleep, verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
read_serial=read_serial,
read_state=read_state,
describe_plan=describe_plan, send=send)
return self._run(address, op, timeout=S3_EVENT_TIMEOUT, retry=False)
def _run(self, address: UnitAddress, fn: Callable[[Any], Any], timeout: Optional[float] = None,
retry: bool = True) -> Any:
def attempt() -> Any:
client = self._factory(address) if timeout is None else self._factory(address, timeout=timeout)
try:
client.open()
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
try:
return fn(client)
except DeviceError:
raise
except Exception as exc:
raise translate(exc, connecting=False) from exc
finally:
_close(client)
try:
return attempt()
except NoAnswer:
# A MiniMate that has just had its serial lines asserted can take
# 5-10 s to boot, and shows it as silence; one retry covers it. TCP
# only -- on a serial cable a silence is a real fault. Narrower than
# server._run_with_retry (any protocol error): retrying a
# MalformedReply would also retry "no settings block", which a
# reconnect cannot fix.
if not retry or not address.host:
raise
log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key)
return attempt()
@staticmethod
def _check(serial_reported: str, serial: str, address: UnitAddress) -> None:
if (serial_reported or "").strip().upper() != serial:
raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}")
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
def op(client: Any) -> UnitInfo:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
return UnitInfo(
serial=info.serial, series=3, model=info.model, firmware=info.firmware_version,
monitoring=None, active_setup=cc.setup_name if cc else None,
detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version},
)
return self._run(address, op)
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
def op(client: Any) -> UnitStatus:
client.poll()
ms = client.get_monitor_status()
# The change path's reading, not a guess: an unmeasured flag is None.
monitoring = {"monitoring": True, "idle": False}.get(s3_run_state(ms))
return UnitStatus(
serial=serial, series=3, monitoring=monitoring,
battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None,
memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free,
device_time=None, event_count=None,
# Series 3 status reads no serial, so the serial shown is the one requested, not one the unit reported.
detail={"serial_verified": False},
)
return self._run(address, op)
def call_home_state(self, address: UnitAddress, serial: str) -> CallHomeState:
"""The unit's call-home switch and dial string (0x2C), after a wake. Like
status, it reads no serial: the one shown is the one requested."""
def op(client: Any) -> CallHomeState:
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
raw = client.read_call_home_raw()
image = unescape_reply(raw)
detail = {"byte5": f"0x{image[5]:02X}" if len(image) > 5 else None,
"block": bytes(raw).hex(), "serial_verified": False}
if not is_call_home_block(raw):
detail["reason"] = f"the unit {S3_CALL_HOME_WHILE_MONITORING}"
return CallHomeState(serial=serial, series=3, enabled=None, dial_string=None, detail=detail)
dial = bytes(image[6:46]).split(b"\x00", 1)[0].decode("ascii", errors="replace") or None
return CallHomeState(serial=serial, series=3, enabled=call_home_enabled(raw),
dial_string=dial, detail=detail)
return self._run(address, op)
def change_call_home(self, address: UnitAddress, serial: str, *, enabled: bool, dry_run: bool,
even_if_already: bool, audit: Any, caller: str,
sleep: Callable[[float], None], verify_timeout_s: float,
verify_interval_s: float) -> ChangeResult:
"""Series-3 pieces for the shared core: read 0x2C, set byte 5 of the
unescaped image, send it (0x7E) and confirm (0x7F), re-read. One attempt,
never retried; refused live until the frame is verified against Blastware."""
if not dry_run and not S3_CALL_HOME_FRAME_VERIFIED:
raise NotSupported("a MiniMate call-home write waits until its frame has been "
"reproduced from a Blastware capture -- nothing sent")
what = "call-home " + ("enable" if enabled else "disable")
def op(client: Any) -> ChangeResult:
reads: list = []
images: list = []
def read_serial() -> str:
return client.connect().serial or "" # a fresh connection: the 0x15 read
def read_state() -> str:
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
raw = client.read_call_home_raw()
if not is_call_home_block(raw):
raise UnitStateUnknown(f"{serial} {S3_CALL_HOME_WHILE_MONITORING} -- nothing sent")
reads.append(raw)
on = call_home_enabled(raw)
if on is None:
image = unescape_reply(raw)
return f"unknown(0x{image[5]:02X})" if len(image) > 5 else "unknown(short)"
return "enabled" if on else "disabled"
def describe_plan() -> dict:
try:
image = call_home_image(reads[-1], enabled)
except ValueError as exc:
images[:] = []
return {"action": what, "steps": [], "warnings": [f"{exc}; nothing would be sent"]}
images[:] = [image]
warnings = []
if image == write_image(SUB_CALL_HOME_WRITE, reads[-1]):
warnings.append(f"the unit is already call-home {'enabled' if enabled else 'disabled'}"
" -- this write changes nothing")
return {"action": what, "warnings": warnings, "steps": [
{"sub": f"0x{SUB_CALL_HOME_WRITE:02X}", "what": "call-home config write",
"data_len": len(image), "frame": build_bw_write_frame(SUB_CALL_HOME_WRITE, image).hex()},
{"sub": f"0x{SUB_CALL_HOME_CONFIRM:02X}", "what": "call-home config confirm",
"data_len": 0, "frame": build_bw_write_frame(SUB_CALL_HOME_CONFIRM, b"").hex()}]}
def send() -> dict:
client.write_call_home_image(images[0])
return {"subs": [f"0x{0xFF - SUB_CALL_HOME_WRITE:02X}", f"0x{0xFF - SUB_CALL_HOME_CONFIRM:02X}"]}
def snapshot() -> dict:
before = write_image(SUB_CALL_HOME_WRITE, reads[0])
after = write_image(SUB_CALL_HOME_WRITE, reads[-1])
return {"before": before.hex(), "after": after.hex(),
"changed_offsets": [i for i in range(min(len(before), len(after)))
if before[i] != after[i]]}
return run_change(
kind=call_home_change(enabled), serial=serial, series=3, dry_run=dry_run,
even_if_already=even_if_already, audit=audit, address=address, caller=caller,
sleep=sleep, verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
read_serial=read_serial, read_state=read_state,
describe_plan=describe_plan, send=send, snapshot=snapshot,
# raised before the frame goes out: audited as nothing sent
is_refusal=lambda e: isinstance(e, ImageRefused))
return self._run(address, op, retry=False)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
def op(client: Any) -> UnitSettings:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
if cc is None:
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
mode = None
if cc.recording_mode is not None:
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
notes = {
label: value for label, value in (
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
) if value is not None
}
return UnitSettings(
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
notes=notes,
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
"geo_range": cc.geo_range},
)
return self._run(address, op)
def list_events(self, address: UnitAddress, serial: str) -> EventList:
def op(client: Any) -> EventList:
info = client.connect()
self._check(info.serial, serial, address)
return EventList(serial=serial, series=3,
events=[_s3_ref(ev, serial) for ev in client.list_event_headers()])
# The default timeout: a header walk is small replies only, so a lost
# one costs 10 s (TCP) with the unit locked, not 120 s.
return self._run(address, op)
def download_event(self, address: UnitAddress, serial: str, key: bytes,
stamp: Optional[str]) -> DownloadedEvent:
# The walk compares this with the target's 0C and, on a mismatch, sends
# no 5A: a stale id costs a header walk, not a full download of the
# wrong event.
iso = datetime.datetime.strptime(stamp, "%Y%m%d%H%M%S").isoformat() if stamp is not None else None
def op(client: Any) -> DownloadedEvent:
info = client.connect()
self._check(info.serial, serial, address)
try:
ev = client.download_event_by_key(key, expected_timestamp=iso)
except struct.error as exc:
# Defensive. This once caught the 64 KB page bug (TERM's offset driven
# negative); the walk is 32-bit linear since 2026-10-26 and no longer
# produces it, so reaching here is a new fault.
raise MalformedReply(
f"event {key.hex()}: its download could not be assembled ({exc}); not saved"
) from exc
if ev is None:
raise EventNotFound(f"no event {key.hex()} on {serial} -- list the events again")
found = stamp_of(_s3_dt(ev))
if stamp is not None and found is None:
raise MalformedReply(
f"could not read event {key.hex()}'s record (0C) to confirm it is the one "
"listed -- not downloaded; try again")
if stamp is not None and found != stamp:
raise StaleEvent(
f"the event at {key.hex()} on {serial} is from {found}, not {stamp} -- "
"the unit was erased or wrapped since the list was read; list again")
if not ev._a5_frames:
raise MalformedReply(f"event {key.hex()}: no waveform data received (the 5A download failed)")
filename = _s3_filename(ev, serial)
if filename is None:
raise MalformedReply(f"event {key.hex()} has no usable timestamp, so it cannot be named or stored")
verified, why = verify_s3_download(ev, info.compliance_config)
try:
bw_bytes = blastware_file_bytes(ev, ev._a5_frames)
except ValueError as exc:
raise MalformedReply(
f"event {key.hex()}: its Blastware file could not be assembled ({exc}); not saved"
) from exc
filename = with_type_letter(filename, bw_bytes) # ...900 -> ...900H, from the file's own bytes
return DownloadedEvent(
event_id=make_event_id(serial, key, found), serial=serial, series=3,
filename=filename, verified=verified, event=ev, a5_frames=ev._a5_frames,
bw_bytes=bw_bytes,
compliance=info.compliance_config, timestamp=_s3_dt(ev),
detail={"a5_frames": len(ev._a5_frames), "check": why},
)
return self._run(address, op, timeout=S3_EVENT_TIMEOUT)