fix(sfm): a monitoring MiniMate's call-home says 'stop monitoring first', not 'unknown(0x6E)'
Measured at the bench 2026-11-03 (BE9441): while monitoring, a MiniMate answers
the 0x2C call-home read with its DEVICE-INFO block ('Instantel', 'MiniMate Plus',
its serial) -- as it answers 1A -- and idle again, minutes later, the call-home
block. SFM writes back only a block it just read, so a monitoring MiniMate's
call-home cannot be changed; the change core already refused (byte 5 read as
'unknown(0x6E)', nothing sent), but said so cryptically.
- minimateplus.protocol.is_call_home_block(raw): the block starts with its own
length 0x7C and is N (or N + 2) bytes unescaped; the device-info block fails it.
- The Series-3 change raises UnitStateUnknown (409) with 'did not return its
call-home settings -- a MiniMate answers the call-home read with its
device-info block while monitoring; stop monitoring first ... nothing sent',
for a dry run too. call_home_state returns enabled = None with that reason.
- The page's callHomeRows shows the reason in place of 'Unknown (byte 5 = ...)'.
A blind write while monitoring stays untested on purpose.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
9820a5389f
commit
5326e99ac2
5 files changed
+71
-6
No files matched your search
@@ -169,6 +169,17 @@ class ImageRefused(ValueError):
|
||||
"""A write refused before any byte was sent: the image is not a whole block."""
|
||||
|
||||
|
||||
def is_call_home_block(raw: bytes) -> bool:
|
||||
"""Whether a 0x2C reply payload is the call-home block: it starts with its own
|
||||
length N = 0x7C (00 7C DC on every read on record) and is N (or N + 2) bytes
|
||||
unescaped. A MONITORING MiniMate answers the read with its device-info block
|
||||
instead (00 00 00 08 'Instantel' ..., measured 2026-11-03 on BE9441), which
|
||||
fails this."""
|
||||
image = unescape_reply(bytes(raw))
|
||||
n = DATA_LENGTHS[SUB_CALL_HOME]
|
||||
return len(image) >= 3 and int.from_bytes(image[:2], "big") == n and len(image) in (n, n + 2)
|
||||
|
||||
|
||||
def call_home_enabled(raw: bytes) -> Optional[bool]:
|
||||
"""The call-home switch of a `0x2C` reply payload, read UNESCAPED (an escaped
|
||||
byte before it would move the raw index -- bench finding #1's lesson): byte 5,
|
||||
|
||||
+17
-5
@@ -13,12 +13,12 @@ from minimateplus.event_file_io import _GEO_INT16_FS
|
||||
from minimateplus.framing import build_bw_write_frame, unescape_reply
|
||||
from minimateplus.protocol import (
|
||||
SUB_CALL_HOME_CONFIRM, SUB_CALL_HOME_WRITE, SUB_START_MONITORING, SUB_STOP_MONITORING,
|
||||
ImageRefused, call_home_enabled, call_home_image, write_image,
|
||||
ImageRefused, call_home_enabled, call_home_image, is_call_home_block, write_image,
|
||||
)
|
||||
from minimateplus.transport import TcpTransport
|
||||
|
||||
from .errors import (DeviceError, EventNotFound, MalformedReply, NoAnswer, NotSupported, StaleEvent,
|
||||
WrongUnit, translate)
|
||||
UnitStateUnknown, WrongUnit, translate)
|
||||
from .change import call_home_change, monitoring_change, run_change
|
||||
from .events import iso_of, make_event_id, stamp_of
|
||||
from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress,
|
||||
@@ -39,6 +39,13 @@ S3_EVENT_TIMEOUT = 120.0 # what the legacy event-download routes use
|
||||
# writes (BE11529, 2026-04-20) byte for byte from the unit's own reads.
|
||||
S3_CALL_HOME_FRAME_VERIFIED = True
|
||||
|
||||
# Measured 2026-11-03 (BE9441): while monitoring, a MiniMate answers the 0x2C read
|
||||
# with its device-info block, as it answers 1A -- its call-home settings cannot be
|
||||
# read, so they cannot be changed (SFM writes back only a block it just read).
|
||||
S3_CALL_HOME_WHILE_MONITORING = ("did not return its call-home settings -- a MiniMate answers the "
|
||||
"call-home read with its device-info block while monitoring; "
|
||||
"stop monitoring first, then change call-home")
|
||||
|
||||
# The 0x1C flag byte (section[1]): the only values ever measured. 0x10 is
|
||||
# BE11529 monitoring (2026-04-08); 0x0B is BE9441 recording a histogram,
|
||||
# confirmed at the unit (2026-10-26). Anything else is refused for a change.
|
||||
@@ -349,11 +356,14 @@ class Series3Adapter:
|
||||
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
|
||||
raw = client.read_call_home_raw()
|
||||
image = unescape_reply(raw)
|
||||
detail = {"byte5": f"0x{image[5]:02X}" if len(image) > 5 else None,
|
||||
"block": bytes(raw).hex(), "serial_verified": False}
|
||||
if not is_call_home_block(raw):
|
||||
detail["reason"] = f"the unit {S3_CALL_HOME_WHILE_MONITORING}"
|
||||
return CallHomeState(serial=serial, series=3, enabled=None, dial_string=None, detail=detail)
|
||||
dial = bytes(image[6:46]).split(b"\x00", 1)[0].decode("ascii", errors="replace") or None
|
||||
return CallHomeState(serial=serial, series=3, enabled=call_home_enabled(raw),
|
||||
dial_string=dial,
|
||||
detail={"byte5": f"0x{image[5]:02X}" if len(image) > 5 else None,
|
||||
"block": bytes(raw).hex(), "serial_verified": False})
|
||||
dial_string=dial, detail=detail)
|
||||
return self._run(address, op)
|
||||
|
||||
def change_call_home(self, address: UnitAddress, serial: str, *, enabled: bool, dry_run: bool,
|
||||
@@ -378,6 +388,8 @@ class Series3Adapter:
|
||||
def read_state() -> str:
|
||||
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
|
||||
raw = client.read_call_home_raw()
|
||||
if not is_call_home_block(raw):
|
||||
raise UnitStateUnknown(f"{serial} {S3_CALL_HOME_WHILE_MONITORING} -- nothing sent")
|
||||
reads.append(raw)
|
||||
on = call_home_enabled(raw)
|
||||
if on is None:
|
||||
|
||||
@@ -204,8 +204,9 @@ function serialPanes(bySerial, settingsRead) {
|
||||
// enable byte never measured -- shown with the byte, never as On or Off.
|
||||
function callHomeRows(state) {
|
||||
const s = state || {};
|
||||
const d = s.detail || {};
|
||||
const sw = s.enabled === true ? 'On' : s.enabled === false ? 'Off'
|
||||
: `Unknown (byte 5 = ${(s.detail || {}).byte5 ?? '?'})`;
|
||||
: d.reason || `Unknown (byte 5 = ${d.byte5 ?? '?'})`;
|
||||
return [['Call-home', sw], ['Dial string', s.dial_string || '—'], ['Series', s.series]];
|
||||
}
|
||||
/* </device-routing> */
|
||||
@@ -145,3 +145,37 @@ def test_a_pre_wire_refusal_is_recorded_as_nothing_sent():
|
||||
((_, row),) = audit.rows.items()
|
||||
assert (row["outcome"], row["sent"]) == ("failed", 0)
|
||||
assert row["error"].startswith("refused before sending")
|
||||
|
||||
|
||||
|
||||
# Measured 2026-11-03 (BE9441): while monitoring, a MiniMate answers the 0x2C read
|
||||
# with its DEVICE-INFO block ("Instantel", "MiniMate Plus", its serial), not its
|
||||
# call-home block -- as it answers 1A. Idle again, it returns the call-home block.
|
||||
# SFM says so plainly instead of "run state unknown(0x6E)".
|
||||
|
||||
def device_info_shaped(serial=b"BE9441"):
|
||||
"""Shaped like BE9441's reply (its first bytes: 00 00 00 08 'Instantel')."""
|
||||
block = b"\x00\x00\x00\x08Instantel".ljust(26, b"\x00") + b"MiniMate Plus".ljust(16, b"\x00") + serial
|
||||
return block.ljust(126, b"\x00")
|
||||
|
||||
|
||||
def test_a_call_home_block_is_told_from_the_device_info_block():
|
||||
from minimateplus.protocol import is_call_home_block
|
||||
assert is_call_home_block(s3_call_home_raw()) is True
|
||||
assert is_call_home_block(device_info_shaped()) is False
|
||||
|
||||
|
||||
@pytest.mark.parametrize("dry_run", [True, False])
|
||||
def test_a_monitoring_minimate_is_told_to_stop_first_and_nothing_is_sent(dry_run):
|
||||
fake = FakeMiniMateClient(call_home_raw=device_info_shaped())
|
||||
with pytest.raises(UnitStateUnknown) as e:
|
||||
change(adapter(fake), enabled=True, dry_run=dry_run)
|
||||
msg = str(e.value)
|
||||
assert "monitoring" in msg and "stop" in msg and "nothing sent" in msg
|
||||
assert e.value.http_status == 409 and fake.writes == []
|
||||
|
||||
|
||||
def test_the_call_home_state_of_a_monitoring_minimate_says_why():
|
||||
st = adapter(FakeMiniMateClient(call_home_raw=device_info_shaped())).call_home_state(TCP, "BE18193")
|
||||
assert st.enabled is None
|
||||
assert "monitoring" in st.detail["reason"]
|
||||
@@ -327,3 +327,10 @@ def test_call_home_rows():
|
||||
assert r[0] == [["Call-home", "On"], ["Dial string", "RADIO RING"], ["Series", 4]]
|
||||
assert r[1] == [["Call-home", "Off"], ["Dial string", "—"], ["Series", 3]]
|
||||
assert r[2][0] == ["Call-home", "Unknown (byte 5 = 0x07)"]
|
||||
|
||||
|
||||
|
||||
def test_call_home_rows_say_why_a_switch_did_not_read():
|
||||
r = run(["callHomeRows", [{"enabled": None, "dial_string": None, "series": 3,
|
||||
"detail": {"byte5": "0x6E", "reason": "not readable while monitoring -- stop it first"}}]])
|
||||
assert r[0][0] == ["Call-home", "not readable while monitoring -- stop it first"]
|
||||
Reference in new issue
Block a user