s4_change_settings runs the shared change core with a read-back verdict for its state (as asked / unchanged / differs). It reads the active setup's name (unstripped), the preferences, trigger and setup blocks and the schedule; patches the setup through micromate.setup_fields; sends THOR's setup push (0xDA 68 73 82 83 71 72, now enableable) once; reads the setup back. Refused before sending: a monitoring unit, a value the unit does not allow (422), a stale preview (SettingsChanged, 409), and -- shown as 'blocked' in the preview -- the factory setup, a schedule that loads another setup, an unreadable schedule, or a block SFM has not seen (ChangeRefused, 409). s4_settings carries the editable fields. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
423 lines
20 KiB
Python
423 lines
20 KiB
Python
"""setup_fields.py -- the settings an operator can change, for both series (phase 5).
|
|
|
|
Pure byte interpretation: no I/O, no device, no `sfm` and no `minimateplus`
|
|
imports. Every offset is into the settings block's CONTENT:
|
|
|
|
* Series 4: the `0x1A` content, 2,092 bytes (N = 2090, then its CRC).
|
|
* Series 3: the 1A read assembled by `minimateplus.protocol.
|
|
assemble_compliance_content`, 2,090 bytes (N = 2090, no CRC in the read).
|
|
|
|
**One layout.** Measured 2026-11-03: Blastware's MiniMate compliance image IS
|
|
Series IV's `0x1A` content layout (`decode_setup` reads it), and each of
|
|
BE11529's nine 2026-04-20 Blastware writes moved exactly the bytes of the field
|
|
it changed. Series 4's offsets are from the 47-snapshot keypad pass on UM20147
|
|
(2026-10-17/19). Fields measured on one series only are offered on that series
|
|
only.
|
|
|
|
**Limits are the units' own, from Instantel's manuals** (Brian, 2026-11-03: "I
|
|
want to use the actual unit limits, not just what we have done in the past"):
|
|
* geophone trigger 0.005-10 in/s in steps of 0.001 -- MiniMate Plus manual
|
|
716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual
|
|
721U0201 Rev 06, *Geophone Trigger Level* -- and at most the range's full
|
|
scale;
|
|
* record time: Micromate 1-90 s (*Record Time*); MiniMate up to §4.4's
|
|
*Maximum Record Times* for a 1 MB unit, channels 1-4, at the sample rate,
|
|
and 13 s in Histogram Combo (§3.8.9);
|
|
* job number 1-9999 (both manuals).
|
|
What a unit does not take, the read-back shows (`settings_state`).
|
|
|
|
tests/test_setup_fields.py holds this to Blastware's writes and the keypad
|
|
fixtures byte for byte.
|
|
"""
|
|
from __future__ import annotations
|
|
|
|
import hashlib
|
|
import math
|
|
import struct
|
|
from typing import Any, Dict, List, Optional, Set
|
|
|
|
from .setup_block import crc_ok, with_crc
|
|
|
|
|
|
class SettingsValueError(ValueError):
|
|
"""A requested change SFM will not make, said plainly. Nothing is sent."""
|
|
|
|
|
|
# ── Layout ──────────────────────────────────────────────────────────────────
|
|
|
|
_MODE = 5
|
|
_SAMPLE_RATE = slice(6, 8) # u16 BE
|
|
_HIST_INTERVAL = slice(8, 10) # u16 BE seconds
|
|
_RECORD_TIME = 18 # f32 BE seconds
|
|
_REPORT_FLAGS = 39 # bit 0x02 = job number on the report (measured both series)
|
|
_JOB_SHOWN = 0x02
|
|
_JOB_NUMBER = slice(40, 42) # u16 BE
|
|
|
|
_NOTE_LABEL, _NOTE_VALUE, _NOTE_STRIDE, _NOTES = 122, 144, 64, 4
|
|
_NOTE_LABEL_WIDTH, _NOTE_WIDTH = 22, 42
|
|
NOTE_MAX = _NOTE_WIDTH - 1 # a NUL always ends the value
|
|
|
|
_CHANNELS, _CHANNEL_SIZE, _GEOPHONES = 1708, 48, (0, 1, 2)
|
|
_CH_RANGE = 29 # u8: 0 Normal (10 in/s), 1 Sensitive (1.25 in/s) -- Series 3, measured
|
|
_CH_TRIGGER = 30 # f32 BE, in/s for a geophone
|
|
_CH_UNIT = slice(34, 38) # "in." / "in" (the keypad re-renders it); NOT an identifier
|
|
_CH_ALARM = 38 # f32 BE -- Series 3, read; a write waits for the bench
|
|
_FULL_SCALE = {0: 10.0, 1: 1.25}
|
|
_RANGES = {"normal": 0, "sensitive": 1}
|
|
|
|
# Blastware writes these bytes as a fixed value on every write on record (11 of 11,
|
|
# both units); the unit reads `01 7f` there after a monitoring session. Meaning
|
|
# unknown -- SFM writes what Blastware writes. Series 3 only.
|
|
S3_BLASTWARE_FIXED = {26: b"\x00\x00"}
|
|
|
|
# A Series-3 alarm-level write has never been seen; the bench measures one, with
|
|
# Brian's go, before this turns on.
|
|
S3_ALARM_WRITE_MEASURED = False
|
|
|
|
MODES = {
|
|
3: {"single_shot": 0x00, "continuous": 0x01, "histogram": 0x03, "histogram_continuous": 0x04},
|
|
4: {"waveform": 0x01, "manual": 0x02, "histogram": 0x03, "combo": 0x04},
|
|
}
|
|
_MODE_LABELS = {
|
|
"single_shot": "Single Shot", "continuous": "Continuous", "histogram": "Histogram",
|
|
"histogram_continuous": "Histogram + Continuous", "waveform": "Waveform", "manual": "Manual",
|
|
"combo": "Combo",
|
|
}
|
|
SAMPLE_RATES = (1024, 2048, 4096)
|
|
INTERVALS = (2, 5, 15, 60, 300, 900)
|
|
TRIGGER_MIN, TRIGGER_MAX, TRIGGER_STEP = 0.005, 10.0, 0.001
|
|
RECORD_MIN_S = 1.0
|
|
S4_MAX_RECORD_S = 90.0
|
|
S3_MAX_RECORD_S = {1024: 104.0, 2048: 52.0, 4096: 26.0}
|
|
S3_COMBO_MAX_RECORD_S = 13.0
|
|
JOB_MIN, JOB_MAX = 1, 9999
|
|
|
|
_SERIES_FIELDS = {
|
|
3: ("record_mode", "sample_rate", "histogram_interval_s", "record_time_s", "geo_trigger_ips",
|
|
"geo_range", "geo_alarm_ips", "job_number", "job_number_shown",
|
|
"note_1", "note_2", "note_3", "note_4"),
|
|
4: ("record_mode", "sample_rate", "histogram_interval_s", "record_time_s", "geo_trigger_ips",
|
|
"job_number", "job_number_shown", "note_1", "note_2", "note_3", "note_4"),
|
|
}
|
|
_LEVELS = ("geo_trigger_ips", "geo_alarm_ips")
|
|
|
|
|
|
def _ch(k: int) -> int:
|
|
return _CHANNELS + _CHANNEL_SIZE * k
|
|
|
|
|
|
def _f32(c: bytes, offset: int) -> float:
|
|
return struct.unpack_from(">f", c, offset)[0]
|
|
|
|
|
|
def _shown(v: float) -> float:
|
|
"""An f32 as an operator typed it: 0.30000001192 is 0.3."""
|
|
return round(v, 6)
|
|
|
|
|
|
def _note_offsets(n: int) -> tuple:
|
|
label = _NOTE_LABEL + n * _NOTE_STRIDE
|
|
value = _NOTE_VALUE + n * _NOTE_STRIDE
|
|
return label, value
|
|
|
|
|
|
def _note_label(c: bytes, n: int) -> str:
|
|
start, _ = _note_offsets(n)
|
|
raw = c[start:start + _NOTE_LABEL_WIDTH].split(b"\x00")[0]
|
|
text = raw.decode("ascii", "replace").strip().rstrip(":").strip()
|
|
return text or f"Note {n + 1}"
|
|
|
|
|
|
def _note_value(c: bytes, n: int) -> str:
|
|
_, start = _note_offsets(n)
|
|
return c[start:start + _NOTE_WIDTH].split(b"\x00")[0].decode("ascii", "replace")
|
|
|
|
|
|
def field_bytes(series: int) -> Dict[str, Set[int]]:
|
|
"""Every byte each field may move, by content offset."""
|
|
def chans(rel: int, width: int) -> Set[int]:
|
|
return {_ch(k) + rel + i for k in _GEOPHONES for i in range(width)}
|
|
out = {
|
|
"record_mode": {_MODE},
|
|
"sample_rate": set(range(6, 8)),
|
|
"histogram_interval_s": set(range(8, 10)),
|
|
"record_time_s": set(range(_RECORD_TIME, _RECORD_TIME + 4)),
|
|
"geo_trigger_ips": chans(_CH_TRIGGER, 4),
|
|
"geo_range": chans(_CH_RANGE, 1),
|
|
"geo_alarm_ips": chans(_CH_ALARM, 4),
|
|
"job_number": set(range(40, 42)),
|
|
"job_number_shown": {_REPORT_FLAGS},
|
|
}
|
|
for n in range(_NOTES):
|
|
_, v = _note_offsets(n)
|
|
out[f"note_{n + 1}"] = set(range(v, v + _NOTE_WIDTH))
|
|
return {f: out[f] for f in _SERIES_FIELDS[series]}
|
|
|
|
|
|
# ── Reading ─────────────────────────────────────────────────────────────────
|
|
|
|
def _mode_name(c: bytes, series: int) -> str:
|
|
code = c[_MODE]
|
|
for name, value in MODES[series].items():
|
|
if value == code:
|
|
return name
|
|
return f"unknown(0x{code:02x})"
|
|
|
|
|
|
def _range_code(c: bytes) -> int:
|
|
return c[_ch(0) + _CH_RANGE]
|
|
|
|
|
|
def _full_scale(c: bytes, series: int, range_name: Optional[str] = None) -> Optional[float]:
|
|
if series == 4:
|
|
return _FULL_SCALE[0] # Series 4's range byte is not mapped; 10 in/s is the hardware's
|
|
code = _RANGES[range_name] if range_name is not None else _range_code(c)
|
|
return _FULL_SCALE.get(code)
|
|
|
|
|
|
def _s3_max_record(rate: int, mode: str) -> Optional[float]:
|
|
top = S3_MAX_RECORD_S.get(rate)
|
|
if top is None:
|
|
return None
|
|
return min(top, S3_COMBO_MAX_RECORD_S) if mode == "histogram_continuous" else top
|
|
|
|
|
|
def _unit_string(c: bytes) -> List[str]:
|
|
return [c[_ch(k) + _CH_UNIT.start:_ch(k) + _CH_UNIT.stop].replace(b"\x00", b"")
|
|
.replace(b".", b"").decode("ascii", "replace") for k in _GEOPHONES]
|
|
|
|
|
|
def editable_fields(content: bytes, series: int) -> List[Dict[str, Any]]:
|
|
"""The fields an operator can change, described for a form: field, label,
|
|
kind ("number" / "choice" / "text" / "bool"), value, and as relevant unit,
|
|
min, max, step, choices [{value, label}], maxlength, readonly."""
|
|
c = content
|
|
rate = int.from_bytes(c[_SAMPLE_RATE], "big")
|
|
mode = _mode_name(c, series)
|
|
out: List[Dict[str, Any]] = [
|
|
{"field": "record_mode", "label": "Record mode", "kind": "choice", "value": mode,
|
|
"choices": [{"value": n, "label": _MODE_LABELS[n]} for n in MODES[series]]},
|
|
{"field": "sample_rate", "label": "Sample rate", "kind": "choice", "value": rate, "unit": "sps",
|
|
"choices": [{"value": r, "label": f"{r} sps"} for r in SAMPLE_RATES]},
|
|
{"field": "histogram_interval_s", "label": "Histogram interval", "kind": "choice",
|
|
"value": int.from_bytes(c[_HIST_INTERVAL], "big"),
|
|
"choices": [{"value": s, "label": f"{s} s" if s < 60 else f"{s // 60} min"} for s in INTERVALS]},
|
|
{"field": "record_time_s", "label": "Record time", "kind": "number", "unit": "s",
|
|
"value": _shown(_f32(c, _RECORD_TIME)), "min": RECORD_MIN_S,
|
|
"max": S4_MAX_RECORD_S if series == 4 else _s3_max_record(rate, mode)},
|
|
{"field": "geo_trigger_ips", "label": "Geophone trigger", "kind": "number", "unit": "in/s",
|
|
"value": _shown(_f32(c, _ch(0) + _CH_TRIGGER)), "min": TRIGGER_MIN,
|
|
"max": min(TRIGGER_MAX, _full_scale(c, series) or TRIGGER_MAX), "step": TRIGGER_STEP},
|
|
]
|
|
if series == 3:
|
|
code = _range_code(c)
|
|
name = next((n for n, v in _RANGES.items() if v == code), f"unknown(0x{code:02x})")
|
|
out.append({"field": "geo_range", "label": "Geophone range", "kind": "choice", "value": name,
|
|
"choices": [{"value": "normal", "label": "Normal (10 in/s)"},
|
|
{"value": "sensitive", "label": "Sensitive (1.25 in/s)"}]})
|
|
out.append({"field": "geo_alarm_ips", "label": "Geophone alarm", "kind": "number",
|
|
"unit": "in/s", "value": _shown(_f32(c, _ch(0) + _CH_ALARM)),
|
|
"min": TRIGGER_MIN, "max": _full_scale(c, 3) or TRIGGER_MAX,
|
|
"step": TRIGGER_STEP, "readonly": not S3_ALARM_WRITE_MEASURED})
|
|
out.append({"field": "job_number", "label": "Job number", "kind": "number",
|
|
"value": int.from_bytes(c[_JOB_NUMBER], "big"), "min": JOB_MIN, "max": JOB_MAX, "step": 1})
|
|
out.append({"field": "job_number_shown", "label": "Job number on report", "kind": "bool",
|
|
"value": bool(c[_REPORT_FLAGS] & _JOB_SHOWN)})
|
|
for n in range(_NOTES):
|
|
out.append({"field": f"note_{n + 1}", "label": _note_label(c, n), "kind": "text",
|
|
"value": _note_value(c, n), "maxlength": NOTE_MAX})
|
|
return out
|
|
|
|
|
|
def field_values(content: bytes, series: int) -> Dict[str, Any]:
|
|
return {d["field"]: d["value"] for d in editable_fields(content, series)}
|
|
|
|
|
|
def field_rows(before: bytes, written: bytes, series: int, fields, now: Optional[bytes] = None) -> Dict[str, Dict[str, Any]]:
|
|
"""For each changed field: its label, the value the unit had (old), the value
|
|
sent (new) and, given a read-back, what the unit now holds (now)."""
|
|
a, w = field_values(before, series), field_values(written, series)
|
|
n = field_values(now, series) if now is not None else None
|
|
labels = {d["field"]: d["label"] for d in editable_fields(written, series)}
|
|
out: Dict[str, Dict[str, Any]] = {}
|
|
for f in fields:
|
|
row: Dict[str, Any] = {"label": labels[f], "old": a[f], "new": w[f]}
|
|
if n is not None:
|
|
row["now"] = n[f]
|
|
out[f] = row
|
|
return out
|
|
|
|
|
|
# ── Checking ────────────────────────────────────────────────────────────────
|
|
|
|
def _number(field: str, v: Any) -> float:
|
|
if isinstance(v, bool) or not isinstance(v, (int, float)) or not math.isfinite(v):
|
|
raise SettingsValueError(f"{field} must be a number, not {v!r}")
|
|
return float(v)
|
|
|
|
|
|
def _integer(field: str, v: Any) -> int:
|
|
if isinstance(v, bool) or not isinstance(v, int):
|
|
raise SettingsValueError(f"{field} must be a whole number, not {v!r}")
|
|
return v
|
|
|
|
|
|
def check_changes(content: bytes, series: int, changes: Dict[str, Any]) -> Dict[str, Any]:
|
|
"""The changes, normalised -- or SettingsValueError naming the first one SFM
|
|
will not make, and why. Checks names, types and the units' own limits, then
|
|
what depends on this unit's block: its unit strings and its range."""
|
|
if series not in _SERIES_FIELDS:
|
|
raise SettingsValueError(f"Series {series} has no settings SFM can change")
|
|
if not isinstance(changes, dict) or not changes:
|
|
raise SettingsValueError("no settings to change")
|
|
allowed = _SERIES_FIELDS[series]
|
|
out: Dict[str, Any] = {}
|
|
for field, v in changes.items():
|
|
if field not in allowed:
|
|
raise SettingsValueError(f"{field} is not a setting SFM can change on a Series {series} unit")
|
|
if field == "record_mode":
|
|
if v not in MODES[series]:
|
|
raise SettingsValueError(f"record_mode must be one of {', '.join(MODES[series])}, not {v!r}")
|
|
out[field] = v
|
|
elif field == "sample_rate":
|
|
if _integer(field, v) not in SAMPLE_RATES:
|
|
raise SettingsValueError(f"sample_rate must be one of {SAMPLE_RATES}, not {v}")
|
|
out[field] = v
|
|
elif field == "histogram_interval_s":
|
|
if _integer(field, v) not in INTERVALS:
|
|
raise SettingsValueError(f"histogram_interval_s must be one of {INTERVALS} s, not {v}")
|
|
out[field] = v
|
|
elif field == "geo_range":
|
|
if v not in _RANGES:
|
|
raise SettingsValueError(f"geo_range must be normal or sensitive, not {v!r}")
|
|
out[field] = v
|
|
elif field in ("geo_trigger_ips", "geo_alarm_ips"):
|
|
if field == "geo_alarm_ips" and not S3_ALARM_WRITE_MEASURED:
|
|
raise SettingsValueError("the alarm level is shown but not changed yet: a MiniMate "
|
|
"alarm write has never been measured (the bench measures it)")
|
|
x = _number(field, v)
|
|
if not TRIGGER_MIN <= x <= TRIGGER_MAX:
|
|
raise SettingsValueError(f"{field} must be {TRIGGER_MIN}-{TRIGGER_MAX} in/s, not {x}")
|
|
if abs(x - round(x, 3)) > 1e-9:
|
|
raise SettingsValueError(f"{field} must be in steps of {TRIGGER_STEP} in/s, not {x}")
|
|
out[field] = round(x, 3)
|
|
elif field == "record_time_s":
|
|
out[field] = _number(field, v)
|
|
elif field == "job_number":
|
|
if not JOB_MIN <= _integer(field, v) <= JOB_MAX:
|
|
raise SettingsValueError(f"job_number must be {JOB_MIN}-{JOB_MAX}, not {v}")
|
|
out[field] = v
|
|
elif field == "job_number_shown":
|
|
if not isinstance(v, bool):
|
|
raise SettingsValueError(f"job_number_shown must be true or false, not {v!r}")
|
|
out[field] = v
|
|
else: # note_1 .. note_4
|
|
if not isinstance(v, str):
|
|
raise SettingsValueError(f"{field} must be text, not {v!r}")
|
|
if any(not 0x20 <= ord(ch) <= 0x7E for ch in v):
|
|
raise SettingsValueError(f"{field} must be plain printable ASCII (no accents, tabs or "
|
|
"line breaks)")
|
|
if len(v) > NOTE_MAX:
|
|
raise SettingsValueError(f"{field} is {len(v)} characters; the unit holds {NOTE_MAX}")
|
|
out[field] = v
|
|
|
|
# What depends on this unit's block, with the NEW mode / rate / range if they change too.
|
|
c = content
|
|
if "record_time_s" in out:
|
|
t = out["record_time_s"]
|
|
if series == 4:
|
|
top: Optional[float] = S4_MAX_RECORD_S
|
|
else:
|
|
rate = out.get("sample_rate", int.from_bytes(c[_SAMPLE_RATE], "big"))
|
|
top = _s3_max_record(rate, out.get("record_mode", _mode_name(c, series)))
|
|
if top is None:
|
|
raise SettingsValueError(f"this unit's sample rate ({rate}) has no record-time limit "
|
|
"in the manual -- set the sample rate too")
|
|
if not RECORD_MIN_S <= t <= top:
|
|
raise SettingsValueError(f"record_time_s must be {RECORD_MIN_S}-{top:g} s here, not {t}")
|
|
if any(f in out for f in _LEVELS):
|
|
units = _unit_string(c)
|
|
if any(u != "in" for u in units):
|
|
raise SettingsValueError(f"this unit's geophone channels read {units}, not in/s -- only "
|
|
"in/s is measured, so SFM will not change a level")
|
|
full = _full_scale(c, series, out.get("geo_range"))
|
|
if full is None:
|
|
raise SettingsValueError("this unit's geophone range byte is not a value ever measured")
|
|
for f in _LEVELS:
|
|
if f in out and out[f] > full:
|
|
raise SettingsValueError(f"{f} {out[f]} in/s is above the range's full scale ({full} in/s)")
|
|
return out
|
|
|
|
|
|
# ── Writing ─────────────────────────────────────────────────────────────────
|
|
|
|
def encode_setup(content: bytes, series: int, changes: Dict[str, Any]) -> bytes:
|
|
"""`content` with only the changed fields' bytes moved. `changes` should
|
|
come from check_changes; this patches, it does not judge. Bit fields are
|
|
patched bit by bit. Series 3 also writes Blastware's fixed bytes; Series 4
|
|
gets its checksum recomputed."""
|
|
out = bytearray(content)
|
|
for field, v in changes.items():
|
|
if field == "record_mode":
|
|
out[_MODE] = MODES[series][v]
|
|
elif field == "sample_rate":
|
|
out[_SAMPLE_RATE] = int(v).to_bytes(2, "big")
|
|
elif field == "histogram_interval_s":
|
|
out[_HIST_INTERVAL] = int(v).to_bytes(2, "big")
|
|
elif field == "record_time_s":
|
|
struct.pack_into(">f", out, _RECORD_TIME, float(v))
|
|
elif field == "geo_trigger_ips":
|
|
for k in _GEOPHONES:
|
|
struct.pack_into(">f", out, _ch(k) + _CH_TRIGGER, float(v))
|
|
elif field == "geo_alarm_ips":
|
|
for k in _GEOPHONES:
|
|
struct.pack_into(">f", out, _ch(k) + _CH_ALARM, float(v))
|
|
elif field == "geo_range":
|
|
for k in _GEOPHONES:
|
|
out[_ch(k) + _CH_RANGE] = _RANGES[v]
|
|
elif field == "job_number":
|
|
out[_JOB_NUMBER] = int(v).to_bytes(2, "big")
|
|
elif field == "job_number_shown":
|
|
out[_REPORT_FLAGS] = (out[_REPORT_FLAGS] | _JOB_SHOWN) if v else (out[_REPORT_FLAGS] & ~_JOB_SHOWN)
|
|
elif field.startswith("note_") and field[5:].isdigit() and 1 <= int(field[5:]) <= _NOTES:
|
|
_, start = _note_offsets(int(field[5:]) - 1)
|
|
out[start:start + _NOTE_WIDTH] = v.encode("ascii").ljust(_NOTE_WIDTH, b"\x00")
|
|
else:
|
|
raise SettingsValueError(f"{field} is not a setting SFM can change")
|
|
if series == 3:
|
|
for offset, value in S3_BLASTWARE_FIXED.items():
|
|
out[offset:offset + len(value)] = value
|
|
return bytes(out)
|
|
return with_crc(bytes(out))
|
|
|
|
|
|
# ── Reading back ────────────────────────────────────────────────────────────
|
|
|
|
_COMPARED = 2090
|
|
|
|
|
|
def settings_state(before: bytes, written: bytes, now: bytes, *, series: int) -> str:
|
|
"""What a read of the unit says about a change, from the bytes alone:
|
|
"as asked" (it holds what was written), "unchanged" (it holds what it had),
|
|
or "differs". Floats are never compared -- 0.3 is the same f32 both ways.
|
|
Series 4 also needs the unit's own checksum to hold. Series 3 bytes that
|
|
differ only in Blastware's fixed bytes count as as asked: nothing the operator
|
|
asked for is different."""
|
|
a, w, n = before[:_COMPARED], written[:_COMPARED], now[:_COMPARED]
|
|
if series == 4 and not crc_ok(now):
|
|
return "differs"
|
|
if n == w:
|
|
return "as asked"
|
|
if series == 3:
|
|
fixed = {o + i for o, v in S3_BLASTWARE_FIXED.items() for i in range(len(v))}
|
|
if len(n) == len(w) and all(n[i] == w[i] for i in range(len(n)) if i not in fixed):
|
|
return "as asked"
|
|
if n == a:
|
|
return "unchanged"
|
|
return "differs"
|
|
|
|
|
|
def revision(blocks: List[bytes]) -> str:
|
|
"""A short fingerprint of the blocks a preview read; a live change must match it."""
|
|
return hashlib.sha256(b"".join(bytes(b) for b in blocks)).hexdigest()[:16]
|