Final fix wave for phase 3 (start/stop monitoring), per the whole-phase review. - I1 + M2: every failure after the send has started is a ChangeUnconfirmed (audit_id, sent = "acknowledged" | "unknown", the cause's HTTP status) whose message says the frame was sent and names the audit record -- the ring in place of the ack, the four lost-ack follow-ups, and the three read-back paths. Series4Session releases the line on it. Every audit finish goes through one helper; a finish that fails is AuditIncomplete (500) and still says what happened to the unit. The line is kept. - I2: device_commands gains `sent` (1 acknowledged, 0 nothing sent, NULL unknown) and `states` (before / seen / after), with an idempotent ADD COLUMN in _migrate for a table created earlier on this branch. - M1: a RADIO RING already buffered is caught before 0x96/0x97 goes out (pre_send = read_unsolicited, one 10 ms transport read). That is a CallHomeInProgress with sent=0, not ChangeUnconfirmed. - M3: Series 3 reads the raw 0x1C flag (new MonitorStatus.state_flag); a byte other than 0x00/0x10, or a short section, is unknown(...) and refused. - M8: even_if_already on a unit already in the state notes that the read-back proves nothing. - M10: a scan pins `.protocol.execute(` to sfm/device_access/s4.py; both scans fail closed on a file that does not parse. - M11: docs corrected (CLAUDE.md phase-2 sentence, phase-3 bullet, REST list; micromate/protocol.py scope and the 0x49 read_state docstring; s4.py; route docstrings). "No command has ever been originated" is NOT retracted. - M12: GET /db/device_commands normalises the serial. - Minors: unused imports, S3 dry-run frames and 120 s timeout pinned, test rename, serial-cache and short-0x49 tests, _RUN_STATES comment. Schema: two NULLable columns on the branch-new device_commands table, added by _migrate on open; no backfill. No codec change, TOOL_VERSION unchanged. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
14 lines
608 B
Python
14 lines
608 B
Python
"""One door for every device request -- see the 2026-10-20 parity spec."""
|
|
from .errors import (
|
|
AuditIncomplete, AuditUnavailable, BadRequest, CallHomeInProgress, ChangeUnconfirmed,
|
|
ConnectFailed, DeviceError, EventNotFound, MalformedReply, NoAnswer, NotSupported, StaleEvent,
|
|
UnitBusy, UnitStateUnknown, WrongUnit, translate,
|
|
)
|
|
from .models import (
|
|
ChangeResult, DownloadedEvent, EventDownload, EventList, EventRef, UnitAddress, UnitInfo,
|
|
UnitSettings, UnitStatus,
|
|
)
|
|
from .series import normalise_serial, series_for_serial
|
|
from .locks import UnitLocks
|
|
from .access import DeviceAccess
|