First capture of THOR's half of a Micromate call-home, taken with ach_mitm.py
between UM12947's modem and a THOR 1.5.0.29 ACH server on port 8070.
THOR sends POLL (SUB 0x5B, offset 0x0030) and NOTHING ELSE -- four times over
~21 s, then gives up. No greeting, no answer to the RADIO RING, no CONNECT.
And that POLL is BYTE-IDENTICAL to what micromate.protocol builds:
build_request(SUB_POLL, 0x0030) reproduces all four frames exactly.
So the ACH session is PULL, and bridges/mm_ach_server.py already implements it
correctly. The "inbound call-home session" -- carried for weeks as the last
protocol unknown -- was never a separate protocol at all. It is the ordinary
command set on an inbound socket, exactly as series III's 72 captured sessions
suggested it would be.
THE OPEN PROBLEM IS NOW CLEARLY ELSEWHERE. In the same capture the unit sent
only "RADIO RING", four times, and never a protocol frame. THOR polled four
times and got nothing -- identically to our own server in three attempts the
same afternoon. THE VENDOR'S OWN SOFTWARE FAILS THE SAME WAY WE DO, which
eliminates the receiver as a suspect and places the fault between modem and
unit.
Established: cellular healthy (151 ms connect, outbound dial works), bytes do
reach us from the unit's side, modem serial config matches spec (115200 8N1, no
flow control, PAD/TCP), cable is FTDI and cold-booted with it attached. Not
established: whether the unit or the modem emits "RADIO RING" -- it is the
literal string in this unit's own 0x2C dial-string field, and the cheap
disambiguation is to disconnect the unit and see if it still appears.
Next step is a config diff against a working deployed unit's modem, not more
protocol work.