serversdownandClaude Opus 5.5 b3aff4ed66 feat(micromate): get_setup() -- the setup block decoded, checksum-verified, and read off a real unit
MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup:
record mode, sample rate, histogram interval, pre-trigger, stop mode, record
time, auto-stop, active sensors, trigger sources, the three geophone trigger
levels, mic type and (linear) mic trigger, job number, scaled distance, and
the four notes.  MEASURED FIELDS ONLY -- everything graded inferred or
unknown in the reference stays in .raw.

micromate/setup_block.py holds the decode as pure functions (no I/O), plus
crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E.  A failed checksum
raises SetupChecksumError (a ProtocolError) unless verify=False; a short
block raises either way.

Two things the decoder gets right that a naive one would not:
- the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6,
  which hold the stored settings of whichever mic is NOT fitted;
- distance and charge weight convert back with the unit's own 3.2808 and
  2.21, so 45 lb entered on the unit reads 45.0, not 44.89.

TESTS: 69 new.  15 real fixtures (2,103 B each) -- 14 UM20147 reads from the
10-17/10-19 keypad passes, chosen so every field takes at least two values,
plus UM12947's read from Thor's 9-24 capture (other firmware line).
Expected values are what the operator read off the unit's screen, never the
decoder's own output.  Fixtures force-added, per the tests/fixtures/
convention.  Full suite 541 passed; the 16 pre-existing failures
(test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged.

VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded
setup; against UM20147 every line matched the unit's screen (Brian, 10-19).

Also: the scratch harness uses the library checksum and checks all three
blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the
likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first
one this code has met").

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-19 18:20:25 -04:00

539 lines
21 KiB
Python

"""Client-layer tests for the Micromate (series-4) live client.
Every response constant below is a **real data section**, captured from UM12947
(firmware 11.0CB) in ``bridges/captures/9-24-26 - micromate2/``. They are
embedded as hex because the captures are gitignored.
Where a decoded value can be checked against something outside the bytes, it is:
the device clock against the capture's own filename timestamp, the battery
against Thor's event reports (3.8 V), the setup list against what the unit
displays.
"""
from __future__ import annotations
import datetime
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from micromate.client import CONTENT, MicromateClient, _content, _cstring
from micromate.framing import ETX, STX, checksum, stuff
from micromate.protocol import ProtocolError
from micromate.setup_block import SetupChecksumError
FLAGS_CB, FLAGS_THOR = 0xC5, 0x03
# ── Captured response data sections ───────────────────────────────────────────
# Generated from the captures by hand-free extraction -- the hex below is
# verbatim response data, not reconstructed. The trailing comment on each
# names the capture it came from, which is what lets the clock assertions be
# checked against a wall-clock timestamp.
POLL = bytes.fromhex( # 59 B, from_20260924_185113_
"300000000000000000000000000050496e7374616e74656c"
"000600c3f04a00e4194f0074024d4d2f495345452f532f49"
"4f00001f603e7657603e76"
)
SERIAL = bytes.fromhex( # 21 B, from_20260924_191214_
"0a00000000000000000000554d3132393437003100"
)
STATE_IDLE = bytes.fromhex( # 16 B, from_20260924_191214_
"050000000000000000000000e8000b00"
)
STATE_MONITORING = bytes.fromhex( # 16 B, from_20260924_191214_
"050000000000000000000002e8000b00"
)
MS_MONITORING = bytes.fromhex( # 55 B, from_20260924_191214_
"2c00000000000000000000000e180907ea20130c19000000"
"000001000000000000000000000000000000000000017c00"
"e4e1c000e3f1c0"
)
MS_IDLE = bytes.fromhex( # 55 B, from_20260924_191214_
"2c000000000000000000000000180907ea64130d22000000"
"000001000000000000000000000000000000000000017c00"
"e4e1c000e3e1c0"
)
MS_LATE = bytes.fromhex( # 55 B, from_20260925_011403_
"2c000000000000000000000000190907ea74010e05000000"
"000001000000000000000000000000000000000000017c00"
"e4e1c000e3e1c0"
)
# ── Real 11.0BD bytes (UM20147, captured over USB 2026-09-30) ─────────────────
#
# The Thor firmware line, which was pure inference until this capture. These
# are the two responses where BD differs from CB. Captured with
# `mm_client_check.py --capture` and read out of the resulting pair with
# scratch/mm_frame_parse.py, so the data sections are verbatim; only the frame
# wrapper is rebuilt, and the framing is independently verified 251/251.
POLL_BD = bytes.fromhex( # 59 B -- flags 0x03, and the SHORTER model string
"30000000000000000000000000005649"
"6e7374616e74656c000600c3f04a00e4"
"194f0052024d4d2f495345452f530058"
"f406001f60c0755760c075"
)
MS_BD_MONITORING = bytes.fromhex( # 59 B -- FOUR BYTES LONGER than CB's 55
"3000000000000000000000000e1e0907"
"ea600e00310000000000000000000000"
"00000000000000000000000000015e00"
"e4e1c000e291c00fa00004"
)
_SETUP_PAD = 266 - CONTENT
def setup_response(name: str) -> bytes:
"""A 0x41/0x3F/0x40 response: 11-byte prefix then a null-padded name."""
body = name.encode("ascii").ljust(_SETUP_PAD, b"\x00")
return bytes([0xFF]) + bytes(10) + body
# The real 22 names, in the order the unit walked them.
SETUP_NAMES = [
"factory.MMB", "TEST.MMB", "BUS TEST.MMB", "Walsh JV 241.mmb",
"Walsh JV 008.mmb", "Hawbaker 322.mmb", "Hawbaker 322 blasting.mmb",
"min.mmb", "Playhouse Loc 1.mmb", "Valley Rock Solution.MMB",
"RecordingSetup.mmb", "UPMC.mmb", "UPMC Loc 3.mmb", "Residence Inn.mmb",
"Micromate ext trigger.mmb", "Micromate remort alarm.mmb",
"Tree of Life - Loc 1 - 5861 Solway.mmb", "Mele-PWSA-Carroll -Loc 4.mmb",
"Micromate min trigger mmb.mmb", "Fay - Layton Bridge Project.mmb",
"Default Micromate ISEE.mmb", "TEST1.mmb",
]
# ── Test doubles ──────────────────────────────────────────────────────────────
class ScriptedTransport:
def __init__(self, responses: list[bytes]) -> None:
self.queue = list(responses)
self.written: list[bytes] = []
self._connected = False
def connect(self) -> None:
self._connected = True
def disconnect(self) -> None:
self._connected = False
def is_connected(self) -> bool:
return self._connected
def write(self, data: bytes) -> None:
self.written.append(data)
def read(self, n: int) -> bytes:
return self.queue.pop(0) if self.queue else b""
def frame(rsp_sub: int, data: bytes, *, flags: int = FLAGS_CB) -> bytes:
payload = bytes([0x00, flags, rsp_sub, 0x00, 0x00]) + data
return bytes([STX]) + stuff(payload + bytes([checksum(payload)])) + bytes([ETX])
def client(responses: list[bytes], **kw) -> tuple[MicromateClient, ScriptedTransport]:
t = ScriptedTransport(responses)
return MicromateClient(t, recv_timeout=0.5, **kw), t
# ── The captured constants are what we think they are ─────────────────────────
def test_captured_constants_have_the_expected_lengths():
assert len(POLL) == 59
assert len(SERIAL) == 21
assert len(STATE_IDLE) == len(STATE_MONITORING) == 16
assert len(MS_MONITORING) == len(MS_IDLE) == len(MS_LATE) == 55
def test_the_prefix_length_byte_is_only_the_low_byte():
"""⚠ data[0] is `content_length & 0xFF`, with no high byte anywhere.
True for every response under 256 bytes, which is why it reads as a working
length field -- and then loses 2,048 bytes on a setup block. The client
takes content as data[11:] for exactly this reason.
"""
for data in (POLL, SERIAL, STATE_IDLE, MS_MONITORING):
assert data[0] == (len(data) - CONTENT) & 0xFF
assert data[1] == 0x00, "no high byte is stored"
# The two that prove it is not a real length: a 2,092-byte setup block
# reports 44, and a 1,024-byte download chunk reports 0.
assert (2092 & 0xFF) == 44
assert (1024 & 0xFF) == 0
# ── Helpers ───────────────────────────────────────────────────────────────────
def test_a_printable_byte_precedes_the_manufacturer_string():
"""content[2] is 0x50 -- "P". This is why the POLL parse cannot be a scan."""
c = _content(POLL)
assert c[3] == 0x50 and chr(c[3]) == "P"
assert c[4:13] == b"Instantel"
def test_content_strips_exactly_eleven_bytes():
assert _content(SERIAL) == bytes.fromhex("554d3132393437003100")
assert _content(b"short") == b""
def test_cstring_stops_at_the_null():
assert _cstring(bytes.fromhex("554d3132393437003100")) == "UM12947"
assert _cstring(b"\x00rest") == ""
# ── connect() ─────────────────────────────────────────────────────────────────
def test_connect_decodes_identity():
mm, t = client([
frame(0xA4, POLL), frame(0xEA, SERIAL), frame(0xB6, STATE_IDLE),
frame(0xBE, setup_response("TEST1.mmb")),
])
info = mm.connect()
assert info.serial == "UM12947"
assert info.manufacturer == "Instantel"
assert info.model == "MM/ISEE/S/IO"
assert info.firmware_line == "blastware"
assert info.monitoring is False
assert info.active_setup == "TEST1.mmb"
assert "UM12947" in str(info) and "idle" in str(info)
def test_connect_sends_three_reads_not_thors_four():
"""⚠ Deliberately narrower than Thor's POLL -> SERIAL -> 0x49 -> POLL.
The trailing POLL repeats the first; measuring all 8 captured sessions
showed the four-command form is Thor's connection check (3 of 8 sessions),
not a handshake. Only "opens with POLL" is invariant.
"""
mm, t = client([
frame(0xA4, POLL), frame(0xEA, SERIAL), frame(0xB6, STATE_IDLE),
frame(0xBE, setup_response("TEST1.mmb")),
])
mm.connect()
subs = [w[5] for w in t.written] # payload[2] lands at wire[5]
assert subs == [0x5B, 0x15, 0x49, 0x41]
assert 0x01 not in subs, "device info has no Thor precedent; do not read it"
def test_connect_can_skip_the_active_setup():
mm, t = client([frame(0xA4, POLL), frame(0xEA, SERIAL), frame(0xB6, STATE_IDLE)])
info = mm.connect(with_active_setup=False)
assert info.active_setup is None
assert len(t.written) == 3
def test_connect_survives_an_unreadable_active_setup():
"""A unit with no setup loaded is a real state, not a failed connect."""
mm, _ = client([
frame(0xA4, POLL), frame(0xEA, SERIAL), frame(0xB6, STATE_IDLE),
frame(0x00, bytes(20)), # wrong SUB -> UnexpectedResponse
])
info = mm.connect()
assert info.serial == "UM12947"
assert info.active_setup is None
def test_connect_reports_a_monitoring_unit():
mm, _ = client([
frame(0xA4, POLL), frame(0xEA, SERIAL), frame(0xB6, STATE_MONITORING),
frame(0xBE, setup_response("TEST1.mmb")),
])
assert mm.connect().monitoring is True
def test_the_state_flag_is_tested_for_non_zero():
"""⚠ Never compared against 0x02 -- this flag family is not a stable enum.
Its sibling in SUB 0x1C has read both 0x0E and 0x0C while monitoring.
"""
for value in (0x01, 0x02, 0x0C, 0x0E, 0xFF):
data = bytearray(STATE_IDLE)
data[CONTENT] = value
mm, _ = client([
frame(0xA4, POLL), frame(0xEA, SERIAL), frame(0xB6, bytes(data)),
frame(0xBE, setup_response("x.mmb")),
])
assert mm.connect().monitoring is True, f"0x{value:02x} should read as monitoring"
def test_the_model_string_is_anchored_on_MM_not_on_an_offset():
"""The Thor firmware line reports a SHORTER model string, "MM/ISEE/S".
Anchoring on b"MM/" survives that; a fixed end offset would not. A generic
printable-run scan fails for a different reason -- see _parse_poll.
✅ CONFIRMED on real hardware 2026-09-30: UM20147 (11.0BD) read back
model="MM/ISEE/S" over USB. The frame below is still synthesised because
no BD capture is in the repo, but the string it asserts is the real one.
"""
bd = bytearray(POLL)
assert bd[CONTENT + 26:CONTENT + 38] == b"MM/ISEE/S/IO"
bd[CONTENT + 26:CONTENT + 38] = b"MM/ISEE/S\x00\x00\x00"
mm, _ = client([
frame(0xA4, bytes(bd), flags=FLAGS_THOR), frame(0xEA, SERIAL),
frame(0xB6, STATE_IDLE), frame(0xBE, setup_response("x.mmb")),
])
info = mm.connect()
assert info.model == "MM/ISEE/S"
assert info.manufacturer == "Instantel"
assert info.firmware_line == "thor"
# ── get_state() ───────────────────────────────────────────────────────────────
@pytest.mark.parametrize(
"data, monitoring, when, free",
[
(MS_MONITORING, True, datetime.datetime(2026, 9, 24, 19, 12, 25), 0x00E3F1C0),
(MS_IDLE, False, datetime.datetime(2026, 9, 24, 19, 13, 34), 0x00E3E1C0),
(MS_LATE, False, datetime.datetime(2026, 9, 25, 1, 14, 5), 0x00E3E1C0),
],
ids=["monitoring", "idle", "after-midnight"],
)
def test_get_state_decodes_the_real_reads(data, monitoring, when, free):
"""⚠ There is an unidentified byte at content[6]; the hour is at content[7].
The protocol reference's 0x1C section has this right. Its one-line summary
in the divergences list reads as six contiguous fields and does not.
Each expected time is checked against the capture filename that produced the
bytes: 19:12:14, 19:12:14 and 01:14:03. All three decode to seconds-to-a-
minute after their session opened, which is what a device clock should do.
Reading content[6] as the hour gives 32, 100 and 116.
"""
mm, _ = client([frame(0xE3, data)])
st = mm.get_state()
assert st.monitoring is monitoring
assert st.device_time == when
assert st.battery_volts == 3.80 # Thor's reports print 3.8 V
assert st.memory_total_bytes == 15_000_000
assert st.memory_free_bytes == free
assert st.raw == data
def test_content_6_is_not_the_hour():
"""The byte the reference implies is the hour reads 32, 100 and 116."""
for data in (MS_MONITORING, MS_IDLE, MS_LATE):
assert _content(data)[6] not in range(24)
def test_memory_derivations():
mm, _ = client([frame(0xE3, MS_MONITORING)])
st = mm.get_state()
assert st.memory_used_bytes == 15_000_000 - 0x00E3F1C0
assert 0 < st.memory_used_fraction < 0.02
assert "3.80 V" in str(st)
def test_battery_and_memory_are_read_forward_from_content_start():
"""⚠ NOT backward from the end.
This block is 4 bytes longer on the Thor firmware line, and Series III's
from-the-end offsets give a 11.0BD unit a battery reading of 577.92 V. The
extra bytes are trailing, so appending four does not move anything.
"""
bd = MS_MONITORING + bytes.fromhex("0fa00000")
bd = bytes([0x30]) + bd[1:] # low-byte length becomes 48
mm, _ = client([frame(0xE3, bd)])
st = mm.get_state()
assert st.battery_volts == 3.80, "forward offsets must survive the 4 extra bytes"
assert st.memory_total_bytes == 15_000_000
# What the Series III from-the-end offsets would have produced:
assert int.from_bytes(bd[-10:-8], "big") / 100 == pytest.approx(577.92, abs=0.01)
def test_a_dead_clock_battery_does_not_fail_the_whole_read():
"""An impossible date is information; the rest of the block is still good."""
broken = bytearray(MS_MONITORING)
broken[CONTENT + 3] = 0xFF # month 255
mm, _ = client([frame(0xE3, bytes(broken))])
st = mm.get_state()
assert st.device_time is None
assert st.battery_volts == 3.80
def test_a_truncated_state_block_raises():
mm, _ = client([frame(0xE3, bytes(20))])
with pytest.raises(ProtocolError, match="need at least 44"):
mm.get_state()
# ── Setups ────────────────────────────────────────────────────────────────────
def test_list_setups_walks_to_the_empty_terminator():
"""22 real names then an empty one, exactly as the unit walked them."""
responses = [frame(0xC0, setup_response(SETUP_NAMES[0]))]
responses += [frame(0xBF, setup_response(n)) for n in SETUP_NAMES[1:]]
responses += [frame(0xBF, setup_response(""))]
mm, t = client(responses)
assert mm.list_setups() == SETUP_NAMES
assert len(t.written) == 23, "22 names plus the terminator"
assert t.written[0][5] == 0x3F
assert {w[5] for w in t.written[1:]} == {0x40}
def test_list_setups_handles_an_empty_unit():
mm, _ = client([frame(0xC0, setup_response(""))])
assert mm.list_setups() == []
def test_list_setups_refuses_to_loop_forever():
"""A cursor that never advances is a bug, and must not hang the caller."""
from micromate import client as C
mm, _ = client([frame(0xC0, setup_response("a.mmb"))]
+ [frame(0xBF, setup_response("a.mmb"))] * (C._MAX_SETUPS + 5))
with pytest.raises(ProtocolError, match="not advancing"):
mm.list_setups()
def test_get_active_setup_handles_a_long_name():
long_name = "Tree of Life - Loc 1 - 5861 Solway.mmb"
mm, _ = client([frame(0xBE, setup_response(long_name))])
assert mm.get_active_setup() == long_name
# ── Lifecycle ─────────────────────────────────────────────────────────────────
def test_the_client_owns_the_transport():
mm, t = client([])
assert not mm.is_open()
mm.open()
assert mm.is_open() and t.is_connected()
mm.close()
assert not mm.is_open()
def test_context_manager_opens_and_closes():
t = ScriptedTransport([frame(0xA4, POLL), frame(0xEA, SERIAL),
frame(0xB6, STATE_IDLE), frame(0xBE, setup_response("x.mmb"))])
with MicromateClient(t, recv_timeout=0.5) as mm:
assert t.is_connected()
assert mm.connect().serial == "UM12947"
assert not t.is_connected()
# ── The Thor firmware line, on real bytes ─────────────────────────────────────
def test_bd_constants_have_the_lengths_the_parser_reported():
assert len(POLL_BD) == 59
assert len(MS_BD_MONITORING) == 59, "CB is 55; BD is four bytes longer"
assert MS_BD_MONITORING[0] == 0x30, "low-byte length 48 = 59 - 11"
assert MS_IDLE[0] == 0x2C, "the CB equivalent declares 44"
def test_connect_on_a_thor_line_unit():
"""UM20147, real POLL bytes. flags 0x03 is ETX, so it arrives as `10 03`."""
mm, _ = client([
frame(0xA4, POLL_BD, flags=FLAGS_THOR), frame(0xEA, SERIAL),
frame(0xB6, STATE_MONITORING), frame(0xBE, setup_response("test2.MMB")),
])
info = mm.connect()
assert info.firmware_line == "thor"
assert info.model == "MM/ISEE/S", "the BD model string is shorter than CB's"
assert info.manufacturer == "Instantel"
assert info.monitoring is True
def test_poll_content_3_is_not_a_constant():
"""⚠ 0x50 on UM12947, 0x56 on UM20147 -- it VARIES between units.
This is why the manufacturer is read at the fixed offset content[4] and not
by scanning: content[3] is printable in both cases ("P" and "V"), so a
printable-run scan would return "PInstantel" on one unit and "VInstantel" on
the other. Whatever the byte is, it is not a stable marker to anchor on.
"""
assert _content(POLL)[3] == 0x50
assert _content(POLL_BD)[3] == 0x56
assert chr(_content(POLL_BD)[3]) == "V"
def test_get_state_on_a_thor_line_unit():
"""⚠ THE test for the forward-offset decision. Real UM20147 bytes.
The 0x1C block is four bytes longer here, and the extras are TRAILING, so
offsets measured from the start of content are unmoved. Series III reads
battery and memory from the END of this block; test_series_iii_offsets_...
below shows what that produces.
"""
mm, _ = client([frame(0xE3, MS_BD_MONITORING, flags=FLAGS_THOR)])
st = mm.get_state()
assert st.monitoring is True
assert st.device_time == datetime.datetime(2026, 9, 30, 14, 0, 49)
assert st.battery_volts == 3.50
assert st.memory_total_bytes == 15_000_000
assert st.memory_free_bytes == 14_848_448
def test_series_iii_from_the_end_offsets_give_577_volts_on_a_bd_unit():
"""The exact number the protocol reference warned about, now demonstrated.
577.92 V is not a plausible battery reading for anything, which is what
makes it a free self-check -- bridges/mm_client_check.py watches for it.
"""
assert int.from_bytes(MS_BD_MONITORING[-10:-8], "big") / 100 == 577.92
def test_the_four_extra_bd_bytes_are_not_all_zero():
"""⚠ The reference records them as `0f a0 00 00`; UM20147 sent `0f a0 00 04`.
Only the first two bytes look fixed. Nothing reads them, but a future
decoder must not treat the last one as padding.
"""
assert _content(MS_BD_MONITORING)[44:] == bytes.fromhex("0fa00004")
assert _content(MS_IDLE)[44:] == b"", "the CB block has no such tail"
# ── get_setup() ───────────────────────────────────────────────────────────────
# Decoding itself is covered field by field in test_micromate_setup.py; these
# check the client's read, its framing round trip and the verify switch.
SETUP_FIXTURES = os.path.join(os.path.dirname(os.path.abspath(__file__)), "fixtures", "micromate-setup")
def _setup_read(name: str) -> bytes:
with open(os.path.join(SETUP_FIXTURES, f"{name}.bin"), "rb") as f:
return f.read()
def test_get_setup_is_one_read_of_0x1a():
"""One frame -- not Series III's four-frame compliance sequence."""
mm, t = client([frame(0xE5, _setup_read("um20147_baseline"))])
mm.get_setup()
assert [w[5] for w in t.written] == [0x1A]
def test_get_setup_survives_a_literal_dle_through_the_framing():
"""4096 sps puts 0x10 in the payload, which the unit must escape on the wire
and the parser must unescape. Wrong either way and the rate reads wrong or
the CRC fails."""
mm, _ = client([frame(0xE5, _setup_read("um20147_4096sps"))])
s = mm.get_setup()
assert s.sample_rate == 4096
assert s.raw == _setup_read("um20147_4096sps")[CONTENT:]
def test_get_setup_raises_on_a_corrupt_read_by_default():
data = bytearray(_setup_read("um20147_baseline"))
data[CONTENT + 5] = 0x05
mm, _ = client([frame(0xE5, bytes(data))])
with pytest.raises(SetupChecksumError):
mm.get_setup()
def test_get_setup_verify_false_returns_the_corrupt_read():
data = bytearray(_setup_read("um20147_baseline"))
data[CONTENT + 5] = 0x05
mm, _ = client([frame(0xE5, bytes(data))])
assert mm.get_setup(verify=False).record_mode == 0x05