Files
seismo-relay/tests/test_device_access_s3.py
T
serversdownandClaude Opus 5.5 5c6ca049c8 feat(sfm): Series-3 adapter -- identify, status, settings into the shared models
Connect-per-request with the TCP cold-boot retry kept; a different unit answering is refused (409) whenever the serial is already in hand.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:10:23 -04:00

87 lines
3.4 KiB
Python

"""The Series-3 adapter: connect-per-request, mapped into the shared models."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import minimateplus.protocol as mmp_proto # noqa: E402
from device_access_fakes import FakeMiniMateClient # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
ConnectFailed, MalformedReply, NoAnswer, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s3 import Series3Adapter # noqa: E402
TCP = UnitAddress(host="10.0.0.5", tcp_port=12345, port=None, baud=None)
SERIAL_LINK = UnitAddress(host=None, tcp_port=None, port="/dev/ttyUSB0", baud=None)
def adapter(*clients):
queue = list(clients)
return Series3Adapter(client_factory=lambda address: queue.pop(0))
def test_identify_maps_device_info():
fake = FakeMiniMateClient()
info = adapter(fake).identify(TCP, "BE18193")
assert (info.serial, info.series, info.model, info.firmware) == ("BE18193", 3, "MiniMate Plus", "S338.17")
assert info.active_setup == "BRIDGE-A"
assert info.monitoring is None # connect() does not read it on Series 3
assert fake.closed == 1
def test_a_different_unit_answering_is_refused():
fake = FakeMiniMateClient(serial="BE11529")
with pytest.raises(WrongUnit, match="BE18193.*BE11529"):
adapter(fake).identify(TCP, "BE18193")
assert fake.closed == 1
def test_status_maps_monitor_status():
fake = FakeMiniMateClient(monitoring=True)
st = adapter(fake).status(TCP, "BE18193")
assert (st.series, st.monitoring, st.battery_volts) == (3, True, 6.8)
assert (st.memory_total_bytes, st.memory_free_bytes) == (983026, 900000)
assert st.event_count is None and st.device_time is None
assert fake.calls == ["poll", "get_monitor_status"]
def test_settings_maps_the_compliance_config():
s = adapter(FakeMiniMateClient()).settings(TCP, "BE18193")
assert s.record_mode == "Continuous"
assert (s.sample_rate, s.record_time_s, s.histogram_interval_s) == (1024, 3.0, 300)
assert s.geo_trigger_ips == 0.5
assert s.setup_name == "BRIDGE-A"
assert s.notes == {"Project": "Bridge job", "Client": "Acme", "User Name": "BH", "Seis Loc": "Loc 1"}
assert s.detail["record_mode_code"] == 0x01
def test_settings_without_a_compliance_read_is_a_malformed_reply_and_not_retried():
# One fake only: a retry would ask the factory for a second and fail.
with pytest.raises(MalformedReply, match="settings"):
adapter(FakeMiniMateClient(compliance=None)).settings(TCP, "BE18193")
def test_a_cold_unit_over_tcp_gets_one_retry():
first = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("cold")])
second = FakeMiniMateClient()
info = adapter(first, second).identify(TCP, "BE18193")
assert info.serial == "BE18193"
assert first.closed == 1 and second.closed == 1
def test_a_serial_link_is_not_retried():
fake = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("quiet")])
with pytest.raises(NoAnswer):
adapter(fake).identify(SERIAL_LINK, "BE18193")
def test_a_failed_connect_is_connect_failed_and_not_retried():
fake = FakeMiniMateClient(open_error=ConnectionRefusedError("refused"))
with pytest.raises(ConnectFailed, match="could not connect"):
adapter(fake).identify(TCP, "BE18193")