serversdownandClaude Opus 5 5d3963b545 docs: record the 2026-08-25 body-codec and geo-scale findings
Brings the protocol reference, CLAUDE.md and the codec RE status doc up
to date with everything confirmed in this pass.

instantel_protocol_reference.md
  - Changelog row for the five findings.
  - S7.6.1: scope table showing the 32000 scale correction applies to
    series-3 waveform, series-3 histogram and series-4 Thor alike, with
    the measured before/after ratios for each.
  - S15: closed "Full channel ID mapping in SUB 5A stream" — resolved by
    the segment-header channel id ([channel][00][00][segment], 0x46=Tran
    0x47=Vert 0x48=Long 0x49=MicL, 1697/1697 verified).  Four new open
    questions: variable-prefix segment descriptors, the histogram codec
    missing peak intervals (26% of channels), UM-series IDF decoding
    ~1000x low, and the Thor per-count LSB residual.
  - NEW Appendix E — Known Device Faults.  Documents the field-observed
    "offset" fault: symptom, why it floods the ACH queue (pedestal
    exceeds the unit's own geo trigger level), the episode table, the
    detection rule that works, what the data rules out (not the
    geophone, not the battery, not environmental, not condensation),
    and the two remaining candidate mechanisms with the test that
    separates them.  Explicitly flags that it is NOT a decode artifact,
    since that mistake has already been made once.

CLAUDE.md
  - Body-codec section: the four framing cases and the channel-id
    finding, with the corpus result.
  - "What's NOT solved": replaced the stale walker-edge-cases bullet
    with the four genuinely open items.

waveform_codec_re_status.md
  - Scale scope table matching the protocol reference.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-25 14:25:26 +00:00
..
2026-02-24 21:19:40 +00:00