serversdownandClaude Opus 5.5 8123d75d72 fix(sfm): page polish from the 1c bench -- #6, #10, #12, #16 (Batch 2)
- #6 Config tab by serial: the empty legacy edit form stays hidden (settings
  are read-only until phase 5); the settings box shows from the start, 'Not read
  yet', and a different unit's settings are never left on screen.
- #10 A start/stop that went out but was not confirmed is no longer called
  'failed'.  The route now adds 'sent' (acknowledged / unknown) and 'audit_id'
  to a ChangeUnconfirmed -- same status, same message -- and the page says
  'Start monitoring not confirmed: <what happened, audit record>'.
- #12 Device tab by serial: the empty legacy Compliance/Project tables are
  hidden behind a pointer to the Config tab; a Micromate's Firmware card reads
  'Thor line (version not read)' (its version string is in 0x01, undecoded).
- #16 A 504 with nothing sent adds: the connection opened, so the modem is
  reachable -- another program (THOR or Blastware) may be holding the line, or
  the unit is busy.  Measured 2026-10-29: THOR polling leaves SFM a 0-byte 504.

New logic lives in sfm/static/device_routing.js (firmwareLabel,
deviceErrorText, changeErrorText, serialPanes) under Node tests; the page glue
in sfm_webapp.js only applies them.  Checked in jsdom against the real page
(served at a fake origin, /static from disk): all four, legacy mode unchanged,
no script errors.