serversdownandClaude Opus 5.5 b4706a30f0 fix(decode): a Blastware file's setup and notes come from its recording-setup block (#44, #45)
Without a paired ASCII report, a Blastware import stored no sample rate,
the record-type byte as its record time (every waveform read "70 s"), a
pre-trigger and sample count read from STRT bytes that are neither, and
blank notes (the reader stopped at the NUL after each label).

- The recording-setup block is found by structure -- 1c 08, the setup
  name, NUL -- not by the name "Standard Recording Setup", which 37% of
  DL2's files do not use.  One match in each of 70,041 archive files.
- Sample rate (uint16 BE, name-42), pre-trigger (f32 BE, name-36) and
  record time (f32 BE, name-30).  A waveform's sample count is the
  decoded count.  A histogram gets a sample rate only: Blastware reports
  neither a record time nor a pre-trigger for one.
- The setup name and the four user notes by position, as bw_ascii_report
  reads them: the labels are operator-editable ("Seis. Loc:",
  "Location:", "Project: ").
- STRT now yields only the waveform key.

Verified against Blastware's own _XML.XML event reports for the 70,042
DL2 archive events that have one (2016-2026): sample rate 70,042/70,042,
record time 6,524/6,524, pre-trigger 6,484/6,484, notes 70,042/70,042,
sample count 6,523/6,524 (one waveform the decoder ends 3 samples short;
separate).  Events imported with an ASCII report are unchanged -- the
report still overlays.

Not changed: the waveform-time estimate still finds the record time by
the marker; moving it would add a validation constraint for 37% of files
and is to be measured first.  The job number is not read yet (2,997
archive events carry one).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-10-29 17:20:39 -04:00

114 lines
4.7 KiB
Python

"""
Setup and note fields read from a Blastware event file alone (#44, #45).
Every expected value below comes from Blastware's own output for the same
file -- its ASCII report or its `_XML.XML` event report -- or, for the bench
file with neither, from the record length and the MiniMate Plus spec, as
written up in #44/#45. None is derived from the decoder under test.
The STRT record's bytes are not these fields: STRT[18] is the record-type
marker (0x46 waveform, 0x0A histogram), which is why every waveform used to
read "70 s".
"""
from __future__ import annotations
from pathlib import Path
import pytest
from minimateplus.event_file_io import read_blastware_file
_FIX = Path(__file__).resolve().parent / "fixtures"
# (file, sample rate, record time s, pre-trigger samples, total samples)
_WAVEFORMS = [
# ASCII report: 1024 sps, 3.0 s, -0.25 s; 3328 samples per channel.
("5-11-26/M529LL1A.SP0", 1024, 3.0, 256, 3328),
# ASCII report: 1024 sps, 1.0 s, -0.25 s.
("decode-re-5-8-26/event-c/M529LK44.AB0", 1024, 1.0, 256, 1280),
# #44/#45: BE9441 bench at 4096 sps, 5 s, 0.25 s -> 21,504 samples.
("minimate-bench-10-26-26-blastware/blastware/K441LTOF.ZI0", 4096, 5.0, 1024, 21504),
# XML: setup "BE16352.set", 1024 sps, 1.0 s, -0.247 s, 1277 sample rows.
("bw-import-fields-10-29-26/R352HIUI.F40W", 1024, 1.0, 253, 1277),
]
@pytest.mark.parametrize("rel,sr,rt,pretrig,total", _WAVEFORMS)
def test_waveform_setup_fields_come_from_the_file(rel, sr, rt, pretrig, total):
ev = read_blastware_file(_FIX / rel)
assert ev.sample_rate == sr
assert ev.rectime_seconds == pytest.approx(rt)
assert ev.pretrig_samples == pretrig
assert ev.total_samples == total
# (file, sample rate) -- ASCII report / XML
_HISTOGRAMS = [
("histogram-mic-off-10-26-26/K441LTOK.QZ0", 2048),
("ts-fix/K441LKZU.C30H", 1024),
("bw-import-fields-10-29-26/M529L4XQ.R30H", 1024),
]
@pytest.mark.parametrize("rel,sr", _HISTOGRAMS)
def test_histogram_sample_rate_comes_from_the_file(rel, sr):
ev = read_blastware_file(_FIX / rel)
assert ev.sample_rate == sr
@pytest.mark.parametrize("rel,sr", _HISTOGRAMS)
def test_histogram_has_no_record_time_or_pretrigger(rel, sr):
# Blastware reports neither for a histogram; the STRT record-type byte
# (0x0A = 10) is not a record time.
ev = read_blastware_file(_FIX / rel)
assert ev.rectime_seconds is None
assert ev.pretrig_samples is None
# (file, setup name, project, client, operator, sensor location)
_NOTES = [
# ASCII report; default labels, location spelled "Seis Loc:".
("5-11-26/M529LL1A.SP0", "Standard Recording Setup",
"Test-5-8-26", "New Client", "Terra-Mechanics - Harrison", "Still Catbed."),
# ASCII report; location spelled "Seis. Loc:". BE9441's bench setup is
# saved as "Standard Recording Setup.set" (#45).
("histogram-mic-off-10-26-26/K441LTOK.QZ0", "Standard Recording Setup.set",
"TestUnit-Minimate", "Terra-Mechanics", "Terra-Mechanics Inc. - Harrison", "Test unit 1"),
# XML; a setup not named "Standard Recording Setup".
("bw-import-fields-10-29-26/R352HIUI.F40W", "BE16352.set",
"JV 241 - 1425 Spanlers Mill Rad", "Walsh Granite JV",
"Terra-Mechanics Inc- D. Harrison", "Loc #1 - 1425 Spanlers Mill Rd"),
# XML (<Location>Test Loc</Location> only); the operator relabelled the
# four note slots "Location:", "Client:", "User Name:", "General:" and
# filled in only the first. Slots are positional, as in the ASCII parser.
("bw-import-fields-10-29-26/M529L4XQ.R30H", "Standard Recording Setup",
"Test Loc", None, None, None),
]
@pytest.mark.parametrize("rel,setup,project,client,operator,location", _NOTES)
def test_notes_come_from_the_file_by_position(rel, setup, project, client, operator, location):
pi = read_blastware_file(_FIX / rel).project_info
assert pi.setup_name == setup
assert pi.project == project
assert pi.client == client
assert pi.operator == operator
assert pi.sensor_location == location
def test_import_without_a_report_stores_the_file_fields(tmp_path: Path):
"""The watcher path with no ASCII report: the sidecar carries what the
file holds, not blanks and not the STRT bytes."""
from sfm.waveform_store import WaveformStore
src = _FIX / "bw-import-fields-10-29-26/R352HIUI.F40W"
store = WaveformStore(tmp_path / "waveforms")
store.save_imported_bw(src.read_bytes(), source_path=src)
sc = store.load_sidecar("BE16352", src.name)
assert sc["event"]["sample_rate"] == 1024
assert sc["event"]["rectime_seconds"] == pytest.approx(1.0)
assert sc["event"]["pretrig_samples"] == 253
assert sc["project_info"]["project"] == "JV 241 - 1425 Spanlers Mill Rad"
assert sc["project_info"]["sensor_location"] == "Loc #1 - 1425 Spanlers Mill Rd"