Files
seismo-relay/minimateplus/decode_check_carveouts.py
T
serversdownandClaude Opus 5.5 c0d837c14f fix(checker): final-review fixes -- regressions, baselines, the PVS carve-out, the headline
- A matching event that now fails outright is a regression: compare_runs
  walks the previous run's matching rows, so a check that collapses to
  one error row no longer hides every field it used to match.  Counts
  moved are taken over the events both runs checked.
- The default baseline is the newest completed run (run.json written) of
  the same scope; a 2,000-event sample is no baseline for a full run.
  changes.md names the previous run's scope.
- The PVS saturation carve-out now needs Blastware's OORANGE, a channel
  Blastware clamped at SFM's ceiling, and SFM's sum within three channels
  at the ceiling -- an unclipped Sensitive-range channel read 8x can no
  longer let an 8x sum through.
- 'Fields fully matching' needs a match: an always-empty element proves
  nothing.  Events without a report are a line of their own.
- CLAUDE.md: histogram PVS described correctly; 35 sub-minute histograms
  plus 2 one-minute no-mic ones, not '~37 sub-minute'.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-10-29 20:11:33 -04:00

90 lines
3.7 KiB
Python

"""
minimateplus/decode_check_carveouts.py — the proven ways Blastware's report
differs from the instrument's data.
Every disagreement between SFM and Blastware is SFM's bug until shown otherwise.
A carve-out is that showing: the fields it covers, the rule it applies, and
evidence that does not rest on SFM's own output -- Blastware contradicting
itself, the instrument's own data, a third source, or Instantel documentation.
`compare` turns a covered mismatch into `accepted` only when the rule holds,
and every run counts the events each carve-out covers.
Pure: no I/O, and no import from `sfm/`.
"""
from __future__ import annotations
from dataclasses import dataclass
from typing import Callable
from .bw_xml_report import XmlReport
from .decode_check import FieldResult, SfmSide, _printed_number, series_pairs, matches_printed
@dataclass(frozen=True)
class Carveout:
id: str
fields: tuple[str, ...] # exact names, or prefixes ending in "."
evidence: str
applies: Callable[[SfmSide, XmlReport, FieldResult], bool]
_TOL = 0.0006
def _at_ceiling(value: float, r: float) -> bool:
"""SFM's value sits at the range ceiling: a decoder unit or two past nominal
full scale is the clipped count itself (32016 = 10.005 in/s). An 8x
Sensitive-range value is far above the band and does not qualify."""
return r - _TOL <= abs(value) <= r * 1.01
def _clamped(printed: str, r: float) -> bool:
if printed.strip() == "OORANGE":
return True
p = _printed_number(printed)
return p is not None and abs(p[0]) >= r - _TOL
def _saturation(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
try:
r = float(ref.scalars["GeoRange"])
except (KeyError, ValueError):
return False
if res.field in ("TranPPV", "VertPPV", "LongPPV"):
v = sfm.values.get(res.field)
return v is not None and _clamped(res.bw or "", r) and _at_ceiling(float(v), r)
if res.field == "PeakVectorSum":
# A vector sum can exceed the range without any clipping, so only
# Blastware's OORANGE counts. SFM's sum is bounded by three channels at
# the ceiling (11.55 on T438HGTZ.B30W), and a channel Blastware itself
# clamped must be the one SFM has at the ceiling -- an unclipped channel
# read 8x high on the Sensitive range does not qualify.
pvs = sfm.values.get("PeakVectorSum")
return ((res.bw or "").strip() == "OORANGE" and pvs is not None
and r - _TOL <= float(pvs) <= 3 ** 0.5 * r * 1.01
and any(_clamped(ref.scalars.get(f, ""), r) and sfm.values.get(f) is not None
and _at_ceiling(float(sfm.values[f]), r)
for f in ("TranPPV", "VertPPV", "LongPPV")))
got = series_pairs(sfm, ref, res.field)
if got is None or got[1]:
return False
differing = [(cell, v) for _, cell, v in got[0] if not matches_printed(v, cell)]
return bool(differing) and all(
_clamped(cell, r) and _at_ceiling(v, r)
and (cell.strip() == "OORANGE" or (v >= 0) == (_printed_number(cell)[0] >= 0))
for cell, v in differing)
SATURATION = Carveout(
id="saturation",
fields=("TranPPV", "VertPPV", "LongPPV", "PeakVectorSum",
"samples.Tran", "samples.Vert", "samples.Long",
"intervals.Tran Peak in/s", "intervals.Vert Peak in/s", "intervals.Long Peak in/s"),
evidence=("Blastware clamps a clipped channel to the range maximum and prints OORANGE; "
"the file holds counts past full scale (32016 counts = 10.005 in/s observed). "
"scratch/verify_against_ascii.py, 2026-08-28."),
applies=_saturation,
)
CARVEOUTS: tuple[Carveout, ...] = (SATURATION,)