serversdownandClaude Opus 5 c07aaa552c fix(series4): support mic-disabled (3-channel) Thor units
Verified against a second Thor corpus (9-10-26-csv-req: UM11402, UM12947,
UM20147) with per-sample CSV exports: 139/139 waveforms exact
(1,273,380/1,273,380 samples) and 877/877 histograms within 2% of Thor's
reported PPV -- up from 66.9% and 56.6%.

Some units run with the microphone disabled, which changes two structural
things that were both hardcoded to the 4-channel shape:

- Waveform body head sat below the scan floor. A 3-channel unit has a
  shorter fixed header and puts its record chain head at 0x0dba, under the
  old _BODY_SCAN_FLOOR of 0x0E00. The scan could not see it and fell
  through to the Vert segment-0 record, decoding a body shifted one
  position around the channel rotation -- Vert came up exactly 512 samples
  short. Floor lowered to 0x0C00. The body-offset scoring also had to stop
  requiring four channels, or `equal` is permanently False for these events
  and the pick falls back to raw sample count.

- Histogram interval record is 56 bytes, not 72. It is
  16 * n_channels + 8, and is not inferable from the segment length alone.
  The interval count now comes from the segment's cumulative counter
  (n = counter - prev_counter) and the stride is derived from it. Assuming
  72 read 7 intervals out of every 10-interval segment, then walked off
  alignment into garbage that decoded as ~10 in/s peaks -- inflating some
  files' PPV by up to 191,000%. Also recovers 4 files that previously
  decoded no intervals at all.

Combined across both corpora: 292/292 waveform files,
2,330,916/2,330,916 samples exact. Production IDFW truncations 41 -> 22.
Series-3 unaffected (no shared-codec change in this commit; last full run
14,338/14,338).

Known open, diagnosed but NOT verified: the remaining 22 unequal + 1 failing
production IDFW files (all UM12947, 2025-07-14..09-23) stop the block walker
on tag 40 0c. data_block_len() caps the 40 NN int16 block at NN > 0x08 while
those files use NN up to 196. Both verified corpora only ever use
NN in {1,2,3,4,8}, so the cap is untested there and lifting it leaves both at
100.000% -- which is not evidence it decodes these correctly. Deliberately
not shipped; needs Thor CSV exports for UM12947 in that date range.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-10 20:00:56 +00:00

553 lines
26 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# IDF Protocol Reference — Thor / Micromate Series IV
Starting-point reference for reverse-engineering Instantel's Micromate
Series IV event-file format. Sibling to
[instantel_protocol_reference.md](instantel_protocol_reference.md) (the
Series III "Rosetta Stone") — this doc holds what we know so far and
the open questions still to crack.
> ⚠ **The "Status (2026-05-28)" block below is SUPERSEDED.** Its geo LSB
> (0.0003), its IDFH scale (`/32768 × 10`), its fixed body offset (`0x0f1f`)
> and its "87–99% byte-exact / loud events truncate" caveat were all wrong or
> incomplete. See **[Verified against Thor's own exports
> (2026-09-10)](#verified-against-thors-own-exports-2026-09-10)** — the
> decoder is now per-sample exact on 1,057,536/1,057,536 samples. The block
> is kept only for the reverse-engineering trail.
**Status (2026-05-28, SUPERSEDED):** ASCII text sidecar fully decoded (1,014
sample files round-trip). **Thor IDFW** binary now decodes via
`micromate.idf_file.read_idf_file()` — reuses the BW segment-rotated
block codec verbatim at fixed body offset `0x0f1f`; metadata (serial,
timestamp, sample_rate, record_time, calibration_date) extracted from
the binary header. Sample fidelity is 87–99% byte-exact on quiet
events; loud events hit the BW codec's known walker-stops-early
limitation. Residual ~3% drift on per-sample deltas (likely a
Thor-specific 12-bit delta refinement not yet modelled).
**Thor IDFH histograms also decoded.** Body has one or more segments;
each 12-byte segment header `[length_be 2B][0a 00 00 00][00 NN][05 3f]`
introduces `N = (length - 10) // 72` interval records of 72 bytes
each. Each interval = 4 × 16-byte per-channel records:
`[int16 min][int16 max][int16 ??][uint16 halfp][2B 00][uint16 ??][2B 00][uint16 ??]`.
Geo peak `= max(|min|, |max|) / 32768 × 10` in/s (matches sidecar
~1.8%); freq `= 512 / halfp` Hz (None for halfp ≤ 5 → ">100"
sentinel). Corpus: **all 859 Thor IDFH files decode, 181,071
intervals**. Wired through `read_idf_file()` →
`save_imported_idf()` → sidecar's `extensions.idf_intervals`.
**Note on the BE9439 outliers in the example corpus:** Two files
(`BE9439_20200713131747.IDFW` and `BE9439_20200713124251.IDFH`) are
**Series III Blastware** binaries, not Thor. Provenance: TMI tried
to use Thor to manage auto-call-homes for Series III units; the
experiment didn't work out, but it did leave a few BW event files
in Thor's per-serial directory structure with `.IDFW`/`.IDFH`
extensions — Thor's forwarder applied its own naming convention to
the BW bodies it was relaying. Their header `10 00 01 80 00 00
Instantel STRT ff fe <end_key> <start_key>` is the BW SUB 5A STRT
record, not a Thor body preamble. The reader detects them by
signature and raises `NotImplementedError` pointing callers at
`read_blastware_file()`, which extracts BW-format peaks from them.
**Still NYI for Thor IDFH:** per-channel `int16 field4` (possibly
time-of-peak); the two uint16 fields (probably PVS contributions);
8-byte interval tail (PVS data); mic dB(L) exact conversion constant.
## Verified against Thor's own exports (2026-09-10)
**The series-4 decoder is now per-sample exact.** 1,057,536 / 1,057,536
geophone samples across all 153 genuine Thor waveform files reproduce Thor's
own CSV export exactly; histogram peaks land within 2% on 858/858 files
(median error −0.004%).
### Ground truth — it was there all along
Thor writes `TXT/`, `CSV/`, `XML/` and `PDF/` exports beside every binary:
```
<serial dir>/UM13981_20220207084555.IDFW
<serial dir>/CSV/UM13981_20220207084555.IDFW.csv
```
The **CSV carries a per-sample block** — four columns (Tran, Vert, Long, Mic)
in in/s and psi, after the 2-column report header. That is the series-4
equivalent of Blastware's `_ASCII.TXT` exports, and it gives 1,012 paired
files (152 IDFW + 860 IDFH). Earlier notes in this file and in
`micromate/idf_file.py` asserted "Thor has no ASCII ground truth in the
corpus"; that was wrong, and it is why the decoder sat pinned to a
superseded walker with a scaling constant nobody could check.
Harness: `scratch/verify_thor_against_csv.py`.
### Geo LSB = 0.000310308 in/s per count (NOT 0.0003)
The old 0.0003 was read off the smallest non-zero sample in the exports —
but that is Thor's **4-decimal display rounding of the LSB, not the LSB**.
It read every series-4 geophone sample **3.3% low**. The quantisation
ladder gives it away: counts 1..6 export as 0.0003, 0.0006, 0.0009, 0.0012,
0.0016, 0.0019 — an LSB of exactly 0.0003 would end 0.0015, 0.0018.
Each exported sample constrains the LSB to the window that rounds to its
printed value. Intersecting 991,415 such constraints gives
```
LSB ∈ [0.000310307933, 0.000310308057] width 1.2e-10
```
so `_GEO_LSB_IPS = 0.000310308`, i.e. full scale 10.0 in/s = **32226.05
counts**. Corroboration: an IDFH interval that never recorded keeps its
min/max accumulator at its ±full-scale seed, and that seed is
`(min=+32226, max=-32226)`. ⚠ The tempting closed form `10.0/32226` is
very slightly wrong — it lands 4.5e-10 above the feasible window and loses
78 boundary samples while never winning one. **Series III uses 32000 counts
for the same 10.0 in/s, so the two generations do not share a scale.**
Independently confirmed on 8 production units (UM6047, UM11402, UM11719,
UM12947, UM13981, UM14133, UM20146, UM20147): every unit's median PPV error
against its device-reported peak moved from −3.3% to within ±0.03%. It is a
global constant, not a per-unit calibration.
### IDFH segment header: the counter is a uint16, and it is cumulative
```
[length_be 2B][0a 00 00 00][counter_be 2B][05 3f]
```
`counter` is the **0-based cumulative index of the last interval in the
segment** — 9, 19, 29, ... for the usual 10-intervals-per-segment layout
(`length` = 730).
The validator used to require `counter`'s high byte to be `0x00`. That
silently **capped every histogram at 250 intervals**: once the cumulative
counter passed 255 the high byte went non-zero and every later segment was
rejected. Any run longer than ~4 hours lost its tail — frequently the part
holding the event peak, so the file's PPV read low. **540 of 858 corpus
files were affected**; fixing it moved histogram peaks from 48.3% to 93.8%
within 0.5% of Thor's reported PPV.
### Unwritten interval slots carry a ±full-scale seed
An interval the device reserved but never wrote keeps `min = +32226`,
`max = -32226` on all four channels — `min > max`, impossible for real data.
Decoded naively it yields a 10.0 in/s peak on every channel and, being a
max-over-intervals, poisons the whole file's PPV. Rare but real: exactly 1
of 497,611 corpus intervals, and it inflated that file's Long PPV from
0.0081 to 10.0 in/s. The inversion is all-or-nothing across channels (0
partial cases), so requiring every channel to be inverted is a safe test.
### Record mode `00 00` — raw int16 absolute (MODE_RAW16)
The record chain's mode field at `off+8` takes a fourth value:
| mode | meaning | header |
|---|---|---|
| `02 00` | deltas + two int16 anchors | 14 B |
| `01 00` | absolute, tagged blocks | 10 B |
| `00 03` | raw 12-bit absolute, untagged | 10 B |
| **`00 00`** | **raw int16 BE absolute, untagged** | **10 B** |
A `MODE_RAW16` record with `length = 1032` carries exactly
`(1032 - 8) / 2 = 512` samples and reproduced Thor's export **512/512
exactly** on first test. Thor uses it for segment 0 (the pre-trigger
window) on some events. Before this mode existed the record fell through
the dispatch unhandled, so the channel silently lost its first 512 samples —
which is what produced the "loud events truncate" symptom.
`MODE_ABSOLUTE` is also valid as a **preamble** (the implicit segment-0 Tran
record); its tagged blocks start at `body[3]`, not `body[7]`, because its
header is 10 bytes rather than 14.
### Body offset is not fixed at 0x0f1f — and 0x0f1f is really a record + 7
A "body offset" is `<record start> + 7`, so that `body[0]` is the segment
index and `body[1:3]` is the mode. The canonical `0x0f1f` is simply the
record at `0x0f18`.
Searching for the literal preamble `00 02 00` finds only MODE_DELTA bodies,
and worse, it **matches the `[seg][mode]` bytes inside any record header**,
so the scan could pick a candidate part-way down the chain. That decodes a
plausible-looking but rotation-shifted body which drops each channel's
segment 0 — the real cause of the remaining truncations.
`_find_waveform_body_offset()` now anchors on record headers (the
`<channel_id> 00 00` signature at `+4`, validated with `is_record()`),
takes the **chain head** — a record no other record's length field points at
— and trial-decodes `head + 7`, preferring the candidate where all four
channels come out the same length.
⚠ Do **not** scan for candidate preambles instead: `MODE_RAW16` is
`00 00`, so every run of three zero bytes looks like a body start and each
costs a full trial decode (~0.5 s/file measured, vs 6 ms/file now).
### Mic-disabled units are a distinct shape (2026-09-10, second corpus)
Some units run with the microphone disabled — **3 channels, not 4** — and that
changes two structural things. Confirmed on the `9-10-26-csv-req` corpus
(UM11402, UM12947, UM20147): 139/139 waveforms and 877/877 histograms.
**Waveform: the body starts earlier.** A 3-channel unit has a shorter fixed
header and puts its record chain head at **`0x0dba`**, below the old
`_BODY_SCAN_FLOOR` of `0x0E00`. The head was therefore invisible to the scan,
which fell through to the *Vert* segment-0 record and decoded a body shifted
one position around the channel rotation. The signature is unmistakable:
```
Tran 3072 / Vert 2560 / Long 3072 / MicL 0 <- Vert exactly 512 short
```
46 of 139 files in that corpus were affected; all 46 became per-sample exact
once the floor dropped to `0x0C00`. Note the body-offset scoring also had to
stop requiring four channels — `len(lengths) >= 3`, not `== 4`, or `equal` is
permanently False for these events and the pick falls back to raw sample count.
**Histogram: the interval record is 56 bytes, not 72.**
```
interval_size = 16 × n_channels + 8 (72 for 4 channels, 56 for 3)
```
It is **not a constant**, and it cannot be inferred from `length` alone.
Derive the interval count from the segment counter — it is cumulative, so
`n = counter - previous_counter` — and then `stride = (length - 10) / n`.
`n_channels` follows from `(stride - 8) / 16`.
Assuming 72 read 7 intervals out of each 10-interval segment and then walked
off alignment into garbage that decoded as ~10 in/s peaks — inflating those
files' PPV by up to 191,000%. Fixing it moved the second corpus from 56.6% to
**100.0%** of histograms within 2% of Thor's reported PPV, and recovered 4
files that previously decoded no intervals at all.
### What is still open
- **23 of 575 production IDFW files (4%)** still decode with unequal channel
lengths (22) or fail outright (1). All are **UM12947, 2025-07-14 to
2025-09-23**. The `Tran/Vert/Long 3072 / MicL 0` group was the 3-channel
shape above and is fixed; what remains is ragged, e.g.
`T1812 / V2132 / L2324 / M2324`.
**Diagnosed but NOT verified.** These files stop the block walker on tag
`40 0c`, because `data_block_len()` caps the `40 NN` int16 block at
`NN > 0x08`:
```python
if hi == 0x40: # int16 BE data block
return (None, None) if (nn == 0 or nn > 0x08) else (2 * nn + 2, nn)
```
The affected files use NN of 12, 16, 20 … up to 196 — every value above 8
halts the walk, which is why the channel comes up short. Both verified
corpora only ever use NN ∈ {1, 2, 3, 4, 8}, so the cap has never been
exercised, and lifting it leaves both at 100.000%.
⚠ **Do not ship the cap change on that evidence.** "Doesn't regress the
known-good corpus" is not "produces correct values here", and a too-loose
guard can accept a false `40 NN` inside data and emit plausible-but-wrong
samples — the exact failure mode this whole effort was about. It needs
Thor CSV exports for UM12947 events between **2025-07-14 and 2025-09-23**;
the `9-10-26-csv-req` upload starts at 2025-09-25 and misses them.
- Mic → psi scale is still the rough `2.14e-6` regression, not derived.
- Per-channel `int16 field4` in the IDFH interval record (possibly
time-of-peak) and the 8-byte tail (PVS data) remain undecoded.
⚠ **Thor's histogram PPV has a display floor of 0.0050 in/s.** In the
production store 6,080 sidecar PPV values are exactly 0.0050 (next most
common value: 275 occurrences), and **41.4% of IDFH sidecars report a
component PPV larger than their own vector sum** — geometrically impossible.
On those quiet files the decoder's ~0.0025 in/s is *more* accurate than the
reference; do not "fix" the decoder to match it.
### Codec breakthroughs (2026-05-28)
- **Body offset is a fixed `0x0f1f`** across 151/154 corpus IDFW
files. Preceded by a 4-byte record-type marker (`46 00 00 00`)
+ magic preamble `00 02 00 [Tran[0] BE] [Tran[1] BE]`.
- **Sample stream is BW's segment-rotated block codec verbatim.**
Thor reuses `10 NN` (nibble), `20 NN` (int8), `00 NN` (RLE),
`30 NN` (packed12), `40 02` (segment header) tags with the same
semantics. Channel rotation Tran→Vert→Long→MicL.
- **Geo LSB = 0.0003 in/s** (not BW's 0.005), because Thor's 16-bit
ADC range maps to 10 in/s without the 16-count BW quantization step.
- **Mic ≈ 2.14×10⁻⁶ psi/count** (rough scale; refine after channel
block calibration constants are decoded).
- **BW compliance anchor `\xbe\x80\x00\x00\x00\x00` reappears at
IDFW offset 0x952** — sample_rate at anchor−6 (uint16 BE),
record_time at anchor+6 (float32 BE), same layout as BW.
- **Event timestamp at offset 0x97A** — 8 bytes `[day][month]
[year_be][unk][hour][min][sec]`. Stop-time mirrors at 0x982.
- **Serial as null-terminated ASCII at 0x14E**.
- **Calibration date** at 0x194–0x197 (day, month, year_be).
- Per-sample residual drift of ~3% suggests Thor encodes int8/nibble
deltas with an extra refinement bit that BW doesn't carry —
unsolved; errors resync within a few samples so cumulative impact
is small.
---
## File model
### Filename convention
```
<SERIAL>_<YYYYMMDDHHMMSS>.<KIND>
```
- **SERIAL** — literal device serial, two-letter prefix + numeric
suffix. Examples seen: `UM11719`, `UM13981`, `UM20147`, `BE9439`.
Unlike Series III BW filenames (`M529LK44.AB0`, base-36 stem),
Series IV filenames carry the serial in plain text.
- **YYYYMMDDHHMMSS** — 14-char ASCII timestamp in **device local
time** (no timezone marker).
- **KIND** — `IDFH` for histograms, `IDFW` for waveforms.
The `.IDFH.txt` / `.IDFW.txt` ASCII sidecar lives in a `TXT/`
**subfolder** of the unit's directory, not alongside the binary.
This pairing convention is encoded in
`event_forwarder.idf_report_path()`.
### Directory layout
```
C:\THORDATA\
└── <Project>\
└── <UM####>\ ← unit serial dir
├── UM12345_20260520100000.MLG ← monitor log (not events)
├── UM12345_20260520100000.IDFH ← histogram event (binary)
├── UM12345_20260520100000.IDFW ← waveform event (binary)
├── UM12345_20260520100000.IDFW.CDB ← cache-DB variant (skip)
├── TXT\
│ ├── UM12345_20260520100000.IDFH.txt ← histogram ASCII sidecar
│ └── UM12345_20260520100000.IDFW.txt ← waveform ASCII sidecar
├── CSV\, HTML\, PDF\, XML\ ← operator-facing derived exports
└── ...
```
The `.IDFW.CDB` files share the binary's basename but appear to be a
separate cache/database variant. Their first 8 bytes match the
**old**-firmware Thor signature (see below) regardless of which
signature the paired `.IDFW` uses. Purpose unknown; sizes vary
wildly (observed 123 B → 40,491 B). Thor-watcher's forwarder
deliberately skips them.
### Sample corpus
The `thor-watcher/example-data/THORDATA_example/` tree carries
**1,014 paired .IDFW / .IDFH + .txt files** spanning 2020–2023
across nine units (UM11719, UM13981, UM20147, …, plus BE9439 from
2020). This is the reverse-engineering ground truth.
---
## ASCII sidecar (`.IDFW.txt` / `.IDFH.txt`) — fully decoded
Shape: plain text, one `"Key : Value"` line per metadata field,
followed for waveforms by a tab-separated sample table headed by
the literal line `Waveform Data Channels`. Parsed by
[`micromate/idf_ascii_report.py`](../micromate/idf_ascii_report.py).
See [`micromate/models.py`](../micromate/models.py) for the typed
`IdfReport` shape.
### Notable conventions
- **Units are native to Thor** — geophone in **in/s**, microphone in
**dB(L)** (not psi like Series III BW reports), frequency in Hz,
acceleration in g, displacement in in.
- **Below-threshold readings** appear as the literal string
`<0.005 in/s` (155 occurrences in the sample corpus) — the parser
strips the `<` and treats the numeric remainder as the value.
- **Out-of-range / not-measured** values appear as `N/A` — parser
drops the field rather than letting the string leak into a numeric
column.
- **Firmware string** observed: `Micromate ISEE 11.0AK`.
- **TitleString1..4** are operator-defined free-text slots; Thor's
default labels map them to Location / Client / Company / Notes,
which the parser surfaces as `project` / `client` / `operator` /
`notes`.
- **Histogram sidecars** use `HistogramStartDate` / `HistogramStartTime`
in place of waveform's `EventDate` / `EventTime`. Parser falls
through to either.
- **Histogram tabular block** lacks the `Waveform Data Channels`
marker; instead it's a multi-line column header followed by
per-interval rows (`<date> <time> <tran-ppv> <freq> ...`). Parser
silently ignores lines after the metadata block since they lack a
colon-separated `key : value` shape (the timestamps DO contain
colons but produce garbage keys that don't collide with any
recognised field).
---
## Binary header signatures (observed)
Hex dump of the first 32 bytes across 1,014 sample files reveals
**two distinct file signatures**, both anchored by the literal
ASCII string `"\x00Instantel\x00"` at offset 6–16:
### Signature A — newer firmware (1,012 files, 99.8% of corpus)
```
00000000: 0012 0100 0000 496e 7374 616e 7465 6c00 ......Instantel.
00000010: 0000 a695 002e b500 4f70 6572 6174 6f72 ........Operator
^^^^^^^^^^^^^^^^
operator/title string starts at 0x18
```
Header bytes 0–5: `00 12 01 00 00 00`. Followed immediately by the
8-byte ASCII tag, then 6 unknown bytes, then ASCII operator-supplied
strings (Operator name, etc.) and on through the project / client /
title strings. No `STRT` record observed in this layout.
### Signature B — older firmware (2 files: BE9439 from 2020)
```
00000000: 1000 0180 0000 496e 7374 616e 7465 6c00 ......Instantel.
00000010: 072c 0012 0300 5354 5254 fffe 0111 2340 .,....STRT....#@
^^^^^^^^^ ^^^^^^^^^
STRT magic 4-byte end_key
00000020: 0111 0000 2e5f 00ac 4600 0000 0200 0000 ....._..F.......
^^^^^^^^^ ^^^
4-byte start_key 0x46 (BW WAVEHDR record-type marker)
```
Header bytes 0–5: `10 00 01 80 00 00`. The structure after the
`Instantel` magic is **byte-for-byte identical to a BW SUB 5A
probe-response STRT record** as documented in
[instantel_protocol_reference.md → "SUB 5A — STRT record encodes
end_offset"](instantel_protocol_reference.md). Specifically:
| Offset | Bytes | Meaning (per BW reference) |
|--------|---------------------|--------------------------------------|
| 0x14 | `53 54 52 54` | `STRT` magic |
| 0x18 | `ff fe` | STRT sentinel |
| 0x1A | `01 11 23 40` | `end_key` (4 bytes) |
| 0x1E | `01 11 00 00` | `start_key` (4 bytes) |
| 0x26 | `46` | `0x46` waveform-record type marker |
**Hypothesis:** Older Micromate firmware writes a wrapped BW-format
event into the `.IDFW` file — essentially the same on-disk shape as
a Series III device, with the new filename convention applied at
export time. Newer firmware (signature A) abandoned the
BW-compatible layout for an Instantel-specific format.
If that hypothesis holds, the 2 signature-B files can already be
parsed via `minimateplus/event_file_io.read_blastware_file()` — worth
testing. The 1,012 signature-A files are the real reverse-engineering
target.
### `.IDFW.CDB` cache files
Always carry signature B (`10 00 01 80 ...`), even when the paired
`.IDFW` carries signature A. Plausible explanation: the CDB is an
internal Thor cache-database export that retains the legacy BW-style
record layout regardless of the user-facing `.IDFW` format version.
Not currently consumed by the forwarder.
---
## File-size patterns (Signature A, the main target)
Survey of 1,012 signature-A files:
| Event type | Typical size | Source of variance |
|--------------|-------------------|----------------------------------------------|
| `.IDFW` 2-sec | 9,200 – 10,500 B | Operator-supplied strings (TitleString1..4) of varying length |
| `.IDFH` | 2,944 – 4,076 B | Histogram interval count (record duration / interval) |
**Naive arithmetic for 2-sec waveform:**
- 4 channels × 2 sec × 1024 sps = 8,192 samples
- At 2 bytes/sample (int16) = 16,384 sample bytes → file would be > 16 KB
- Observed: ~9–10 KB
- → samples are likely **1 byte each** (int8 quantised), **or** stored
with bit-packing / delta encoding, **or** only one channel's
full-rate samples are stored with the others reconstructed
arithmetically. Verifying this is the **first RE milestone**.
Project-string–length variance (~1 KB across the corpus) is consistent
with the file carrying a single copy of each TitleString1..4 plus
operator + setup-name as null-padded ASCII regions.
---
## Open questions
The reverse-engineering targets, roughly in dependency order:
1. **Sample encoding (signature A)** — int8? int16 LE/BE? Bit-packed?
Delta-coded? Per-channel interleaved or sequential blocks?
2. **Header field layout (signature A)** — where do sample_rate,
record_time, channel count, and per-channel peaks live in the
binary? The ASCII sidecar gives the device-authoritative values,
so binary fields can be confirmed by diff.
3. **Operator-string offsets** — `Operator` at 0x18 is the first
visible string in signature-A files; the rest (project, client,
notes, setup) follow. Need to map exact offsets and null-padding
conventions.
4. **Signature-B → BW codec compatibility** — does
`minimateplus/event_file_io.read_blastware_file()` actually parse
the 2 BE9439 signature-B files as-is? If yes, the OLD-format
ingest is free.
5. **`.IDFW.CDB` purpose** — is it an internal Thor cache, a
ring-buffer dump, or something else? Worth a single small effort
to characterise so we know what we're skipping.
6. **Footer / checksum** — every BW event file has a footer; does
IDF? Where does the per-channel sample block end?
---
## Reverse-engineering playbook (when we start)
The Series III BW codec took ~2 months of MITM wire captures
because we didn't have ground-truth metadata. Thor's situation is
**substantially better**:
- **Ground truth is on disk.** Every binary in `example-data/`
has a paired `.IDFW.txt` carrying the full decoded sample table
(`Waveform Data Channels` block — see any sample file in
`thor-watcher/example-data/.../TXT/`). Aligning binary bytes
to the table's float-per-row values gives an immediate per-byte
hypothesis test.
- **Cross-event diffing.** 1,012 signature-A samples from 9 units
spanning 4 years means any field that varies between events is
immediately localisable. Fields that are constant across all
files (firmware ID, channel labels, format-version word) are also
immediately localisable by complementary search.
- **No protocol surface.** Files at rest, not a wire dialect. No
DLE stuffing, no inner-frame parsing, no probe/data two-step.
Suggested first session (2-4 hours): hand-decode `UM11719_20231219162723.IDFW`
(10,290 bytes) against its `TXT/UM11719_20231219162723.IDFW.txt`
sample table (the 2-sec waveform at 1024 sps × 4 channels = 8,192
sample rows). Find the first per-channel sample value (`0.0003` in
the Tran column at t=0) in the binary. Confirms sample encoding.
Everything else flows from there.
---
## Code seams ready to receive the codec
When the codec lands, it goes into
[`micromate/idf_file.py`](../micromate/idf_file.py) (currently a
stub raising `NotImplementedError`). Public API:
```python
from micromate import IdfEvent
from micromate.idf_file import read_idf_file
event: IdfEvent = read_idf_file(Path("UM11719_20231219163444.IDFW"))
# event.peaks.transverse_ips, event.timestamp, event.raw_samples, ...
```
The ingest pipeline (`WaveformStore.save_imported_idf`) currently
builds the `IdfEvent` from the `.txt` parser only. Once
`read_idf_file()` works, the binary becomes authoritative; the
`.txt` parser drops to fast-path metadata cross-check. Operators
who don't enable Thor's TXT exporter still get fully populated
events.
---
## See also
- [instantel_protocol_reference.md](instantel_protocol_reference.md) — Series III BW protocol reference (the Rosetta Stone). STRT record format, DLE framing, BW filename encoding.
- [`micromate/idf_ascii_report.py`](../micromate/idf_ascii_report.py) — `.txt` sidecar parser.
- [`micromate/models.py`](../micromate/models.py) — `IdfEvent`, `IdfReport` typed dataclasses.
- [`micromate/idf_file.py`](../micromate/idf_file.py) — placeholder for the binary codec.
- [`thor-watcher/example-data/THORDATA_example/`](../../thor-watcher/example-data/) — 1,014 paired binary + .txt files for codec validation.