The wedged_unit_recovery runbook covered exactly one failure mode. BE12599 turned out to be a second one wearing the same symptoms, and the existing procedure did not work on it. Adds a "TWO failure modes" table up front so the next incident branches correctly, and a full second-incident section covering what the ALEOS serial debug log revealed: the device repeating a 29-byte AT modem-init string (ATQ1/ATE0/ATS0=2, no ATD) every 75 s, never getting an OK because the modem is in TCP data mode, and therefore never entering S3 mode at all. Inbound cannot win against that, no matter how well framed. Also records the two red herrings, since together they cost ~90 minutes: the RV50 trusted-IP whitelist drops non-listed sources silently (presents as a connect timeout, and Brian's dynamic dev IP had rotated off the list), and sfm/server.py returns 502 for BOTH "Protocol error:" and "Connection error:", so a 502 was misread as "TCP connected, device mute" and a theory built on it. And the gotchas worth never re-deriving: slow_drip's send_error=null plus a full duration is not success (only bytes_received > 0 is); stopping monitoring removes the call-in trigger, so it costs you the channel; --events-only skips the device-info step, so the serial is never read and ach_state keys on peer:ephemeral_port, silently breaking dedup and re-downloading the same event every session. The plan doc captures the tool Brian wants built out of this — a rescue listener with a real lifecycle and, critically, a confirmation gate before shutdown, because leaving the modem's Destination pointed at a dead listener is worse than never having started. Open questions are listed rather than guessed at. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
20 KiB
Runbook — Recovering a wedged unit stuck in a call-home loop
Original incident: BE9558H at 166.246.130.1:9034, recovered 2026-05-17.
A field unit with a stuck-triggered geophone (or any hardware fault causing constant event triggering) will record events back-to-back, and if Auto Call Home is set to "After Event Recorded" the device will dial the office BW ACH server in a tight loop. Combined with a Sierra Wireless modem in bidirectional serial-TCP mode, this makes the unit effectively unreachable from SFM — every TCP connection we open gets killed when the modem flips from server-mode to client-mode to honor the device's next AT dial command.
This runbook describes how to break the loop and recover control.
⚠ There are TWO failure modes under "wedged unit"
Same root cause — an offset/connector fault drives the geophone above trigger, the unit records back-to-back, ACH set to "after event recorded" dials constantly — but the recovery differs, because the thing blocking you is different.
| BE9558H (2026-05) | BE12599 (2026-09) | |
|---|---|---|
| What blocks you | Modem mode-flipping kills inbound TCP | Device never enters S3 mode at all |
| Device state | Alive, in S3 mode, responsive once reached | Stuck repeating an AT modem-init string, deaf to S3 |
| Fix direction | Inbound — clear Destination, slow-drip a Stop | Inverted — point Destination at our own ACH server and let the unit call us |
| Winning tool | scripts/slow_drip.sh |
bridges/ach_server.py --stop-monitoring |
Tell them apart with the ALEOS serial log (see "Turn on ALEOS_SERIAL debug"
below). If the device is emitting ATQ1/ATE0/ATS0=2 every ~75 s, it is in the
BE12599 mode and no amount of inbound work will reach it — skip to
"Second incident" below.
Symptoms
- Terra-View / SFM
/device/infoeither hangs or fails oncount_events(). /device/monitor/statusand/device/rescuereturn 502 (protocol timeout waiting for POLL response) or 503 (TCP connect refused).- ACEmanager serial log shows repeating
Connect to IP: <BW_IP> Port: <BW_PORT>→Shutdown TCP socketcycles every 30-60 seconds. - Spam-mode endpoints (
/device/stop_monitoring_spam) report manysent_okbut the device's monitoring state never changes. slow_dripreports[Errno 32] Broken pipeafter sending the preamble but before completing the drip loop.
If you see all of these, the unit is in this exact failure mode.
Quick reference — how to recover
You need ACEmanager access to the unit's modem.
Step 1: stop the modem's mode-flipping
In ACEmanager → Serial → Port Configuration:
| Field | Set to |
|---|---|
| Destination Address | clear (blank) |
| Destination Port | 0 |
Click Apply. This removes the modem's auto-dial-out target. The device's AT dial commands now error back at the modem instead of triggering a mode-flip, so the modem stays in TCP-server mode permanently and our inbound TCP sessions stay alive.
(Optional belt-and-suspenders: also add the BW server's port to Security → Port Filtering - Outbound as a blocked port, with Outbound Port Filtering Mode = Blocked Ports.)
Step 2: stop monitoring on the device (slow drip)
From the SFM host:
/home/serversdown/seismo-relay/scripts/slow_drip.sh <DEVICE_IP> <PORT>
Defaults are 120s duration with a drip every 3s. Watch the response:
duration_s ≈ 120anddrips_sent ≈ 40→ session held the full duration ✓bytes_received > 0→ device is responding ✓ (this is the success signal)
If duration_s is small or send_error: "Broken pipe", Step 1 didn't take
hold — re-check ACEmanager, may need to reboot the modem after Apply.
Step 3: confirm monitoring stopped
curl 'http://localhost:8200/device/monitor/status?host=<DEVICE_IP>&tcp_port=<PORT>&force=true'
# expect: {"is_monitoring": false, ...}
Step 4: disable ACH at the device level + erase corrupted events
Either fire the rescue endpoint:
/home/serversdown/seismo-relay/scripts/rescue_device.sh <DEVICE_IP> <PORT>
Or do the two steps manually:
# Disable ACH in the device's compliance config
curl -X POST 'http://localhost:8200/device/call_home?host=<DEVICE_IP>&tcp_port=<PORT>' \
-H 'Content-Type: application/json' \
-d '{"auto_call_home_enabled": false}'
# Erase corrupted event chain
curl -X POST 'http://localhost:8200/device/events/erase?host=<DEVICE_IP>&tcp_port=<PORT>'
You can also do this via the SFM standalone UI → Call Home tab → set
Enable Auto Call Home to Disabled → Write to Device.
Step 5: restore modem config (housekeeping)
Once the device-side ACH is disabled, restore the modem's Destination
Address and Port to the original values (e.g. 50.197.32.92 / 12345) in
ACEmanager. The modem will resume normal bidirectional behavior, but the
unit won't issue any dial commands until ACH is explicitly re-enabled on
the device.
Step 6: do NOT re-enable ACH on this unit until the underlying hardware
fault is repaired. If you do, the call-home loop starts again immediately and you'll be running this runbook a second time.
Why this works — the failure mode explained
The Sierra Wireless RV50/RV55 serial port operates in one of two TCP modes at any moment:
- Server mode — listens on
Device Port(e.g. 9034), bridges inbound TCP to the device's serial port. This is what we need to interact with the device. - Client mode — when the device sends an AT dial command on its serial
TX line, the modem opens an outbound TCP to
Destination Address:Portand bridges that to serial.
A serial port in this configuration is bidirectional: the modem flips between server and client modes on demand. When the device's firmware is healthy and only dials occasionally, this works fine.
When the unit is constantly triggering events and ACH is set to "After Event Recorded", the device sends an AT dial command every few seconds. Each one causes the modem to:
- Drop any active inbound TCP session
- Flip to client mode
- Attempt outbound TCP to
Destination Address:Port - Hang for up to a minute waiting for it to succeed/fail
- Drop back to server mode
During the entire hang, no inbound TCP can establish. Even between hangs, the modem closes any existing inbound session before flipping. So any tool that needs more than a few seconds of held TCP (e.g. POLL + config read + write) gets repeatedly kicked off.
Clearing Destination Address removes step 3-4 from the cycle: the modem
has nowhere to dial, so it doesn't flip modes when it receives an AT dial
command. The serial port effectively becomes server-only, and inbound TCP
sessions can stay open as long as needed.
This is a modem-layer issue, not a device firmware issue. The device is alive and responsive the whole time — confirmed in the BE9558H recovery by 990 bytes of S3 responses received over a 120s slow-drip session once the modem was no longer mode-flipping.
Why simpler approaches don't work
| Approach | Why it fails |
|---|---|
Standard /device/info |
Triggers count_events() 1E/1F walk, takes 90s+ and hits corrupted event chain in this scenario |
/device/rescue race loop |
Gets 502 (protocol timeout) because the modem closes the TCP before the POLL handshake can complete |
/device/stop_monitoring_blind (single frame) |
Even if the bytes leave the wire, the device's protocol parser ignores write commands without a preceding POLL handshake (early-version bug, now fixed by including POLL preamble in blind sends) |
/device/stop_monitoring_spam (sub-second cadence) |
Each session is killed by the modem's mode-flip before the device can drain its UART RX buffer; high-rate spam also risks UART FIFO overrun on the device side |
| Outbound port firewall block alone | Stops the outbound TCP from succeeding, but doesn't stop the modem from trying and mode-flipping. Reduces but doesn't eliminate the contention. |
| Modem reboot | Temporary — as soon as the device starts triggering again, the loop resumes within seconds |
The combination of slow_drip + cleared Destination Address works because:
- The modem stops mode-flipping → TCP session stays open for the full drip duration
- Slow drip rate → device's UART RX FIFO never overflows even if firmware is busy with event recording
- The drip is
SESSION_RESET + STOP_MONITORINGevery 3s → many independent chances for the parser to land one valid frame - Once one Stop Monitoring is parsed, event recording halts → firmware has CPU to spare → subsequent operations are trivially easy
Tooling reference
All endpoints live in seismo-relay/sfm/server.py. All scripts live in
seismo-relay/scripts/ and default to SFM direct (http://localhost:8200),
overridable via SFM_BASE_URL.
Endpoints added during BE9558H recovery
| Endpoint | Purpose |
|---|---|
GET /device/events/storage_range |
SUB 0x06 — first/last event keys, is_empty flag. ~2s, no event walk. |
GET /device/events/index |
SUB 0x08 — lifetime event counter (does NOT decrement on erase). ~2s. |
POST /device/events/erase |
Full erase sequence 0xA3 → 0x1C → 0x06 → 0xA2. |
POST /device/rescue |
Disable ACH + erase in one TCP session. Short timeouts for race-loop usage. |
POST /device/stop_monitoring_blind |
Fire-and-forget Stop with full POLL preamble (single attempt). |
POST /device/stop_monitoring_spam |
Server-side tight retry loop, sub-second cadence, duration-bounded. |
POST /device/stop_monitoring_slow_drip |
One held TCP session, slow trickle of stop frames. The endpoint that saved BE9558H. |
Also changed: default protocol recv timeout dropped from 30s → 10s in
_build_client. Added connect_timeout knob to same. Cleaned up
unhandled-exception path in /device/monitor/status so it returns 502
instead of 500 on protocol timeouts.
Scripts
| Script | Purpose |
|---|---|
scripts/rescue_device.sh |
Race-loop wrapper around /device/rescue |
scripts/blind_stop.sh |
Race-loop wrapper around /device/stop_monitoring_blind |
scripts/spam_stop.sh |
Single-call burst hammer (/device/stop_monitoring_spam) |
scripts/slow_drip.sh |
Single-call held-session drip (/device/stop_monitoring_slow_drip) |
scripts/watch_unit.sh |
Passive periodic reachability check, logs to file |
Incident log — BE9558H, 2026-05-16/17
What was wrong: Long-axis geophone developed an offset, constantly above
trigger threshold → constant event recording → after-event ACH set →
modem dialing office BW server (50.197.32.92:12345) every 30-60s.
Local event chain corrupted (next_boundary 0x100EE exceeds uint16).
Diagnostic path:
/device/infoslow, choked on event walk- Built lightweight probe endpoints (
storage_range,index) — useful but didn't reach the wedged unit - Built
/device/rescuewith short timeouts — got 502 (POLL no response) - Built
/device/stop_monitoring_blind— first version was a false positive (no POLL preamble); fixed by includingSESSION_RESET+POLL_PROBE+SESSION_RESET+POLL_DATAin the dump - Verified blind stop works on bench unit
- Built
/device/stop_monitoring_spam— 420 successful sends over 5 min, zero behavior change on field unit - Inspected ACEmanager logs → saw outbound dial-out attempts every ~30s, confirmed device was not fully locked up
- Added outbound port-12345 firewall block → outbound attempts now fail instantly but contention persisted
- Built
/device/stop_monitoring_slow_drip— session died at 3s with broken pipe (modem closing on us) - Looked at full ACEmanager Port Configuration → found
Destination Address: 50.197.32.92configured, realized every AT dial command was triggering a modem mode-flip that killed our inbound - Cleared Destination Address + Port → slow_drip held 120s, device responded with 990 bytes, 39 stop commands acked
- Disabled ACH at device level via
/device/call_home, erased events
Final state: device IDLE, memory 958.1 / 960 KB free, ACH disabled at device level, modem destination cleared (to be restored after physical service).
Total time from "i was wondering if its possible to" first attempt to recovery: ~7 hours of intermittent debugging across one evening.
Second incident — BE12599, 2026-09-16/17
Unit: BE12599 at 166.246.64.226:9034, RV50, job I-80 North Fork Bridge
— Abut 1 West (Fay Company). Same job as BE9558H, which is a coincidence.
Fault: the connector fault documented in docs/offset_investigation.md
§8e progressed until the Tran pedestal reached 0.400 in/s — its trigger
level. Constant triggering → constant recording → ACH "after event recorded"
→ continuous dialing. Same disease as BE9558H.
But the recovery was the opposite direction, and none of the Step 1–4 procedure above worked. Total time ≈ 5 h, of which ~90 min was spent on two red herrings documented below.
Turn on ALEOS_SERIAL debug FIRST
This is the single highest-value diagnostic and it should be step zero on any future incident. ACEmanager → Admin → Log → ALEOS_SERIAL log level → DEBUG, then view the serial log.
It is the only thing that tells you what the device is actually saying. Everything before we did this was guesswork.
What the log showed — the device was never in S3 mode
Every ~75 seconds, verbatim:
ALEOS_SERIAL_HIF: 29 byte(s) in buffer: 'ATQ1^MATE0^MATS0=2^M^MRADIO RING^M'
ALEOS_SERIAL_HMC: TCP recvhost fd 65535 len 29 state TCPMode::kClosed
ALEOS_SERIAL_HMC: tcpmode trying to send to invalid socket
ALEOS_SERIAL_HMC: Connect to IP: 0.0.0.0 Port 0
ALEOS_SERIAL_HMC: Initialize Auto answer on port 9034
ALEOS_SERIAL_HMC: Cannot connect to 0.0.0.0
Read that carefully:
ATQ1(quiet) /ATE0(echo off) /ATS0=2(auto-answer after 2 rings). There is noATD. The device is not dialing — it is trying to configure its modem.- The modem's serial port is in TCP data mode, so it never interprets these as AT commands. It treats them as payload and tries to ship them to a TCP socket that does not exist.
- The device therefore never receives
OK, never progresses, and retries the identical 29 bytes forever.
Consequence: the device is not running the S3 protocol parser. You can land a byte-perfect S3 frame on it and it will be ignored. This is why every inbound approach failed, and it is the structural difference from BE9558H.
Why slow_drip lied
slow_drip returned the success signature except for the one field that
mattered:
{"duration_s":120.0,"drips_sent":38,"bytes_sent":920,
"bytes_received":0,"send_error":null}
Full duration, no broken pipe — but zero bytes back. Cause is in the log
above: each 75 s cycle re-runs Initialize Auto answer on port 9034, which
orphans the held session (data in for unknown reason 3 removing from select, OnMsg recv error: 107 - Transport endpoint is not connected). Our
local TCP stayed open so sendall never raised — but the modem stopped
bridging after the first re-init, so every drip after that went into a socket
nobody was reading.
⚠ send_error: null + full duration is NOT success. Only
bytes_received > 0 is success.
⚠ Two red herrings that cost ~90 minutes
1. The trusted-IP whitelist (this was the real reason inbound never worked)
The RV50s run with Security → Trusted IPs (Friends List) enabled. A
source IP that is not on the list is dropped silently — inbound presents
as Connection error: timed out, never a refusal.
Brian's dev-box public IP is dynamic and had changed, so tmi-dev was no
longer whitelisted. Every inbound attempt failed identically across four
different modem and device states, which looked exactly like the BE9558H
mode-flipping symptom and sent us chasing modem configuration for over an
hour.
Check this before diagnosing anything else. Note that SFM in Docker egresses via the host's public IP, not its LAN IP.
2. A 502 from SFM does not mean TCP connected
sfm/server.py raises 502 for both failure classes:
raise HTTPException(status_code=502, detail=f"Protocol error: {exc}")
raise HTTPException(status_code=502, detail=f"Connection error: {exc}")
We read an early 502 as "TCP connected, modem bridged, device mute" and built
a whole theory on it. It was almost certainly a connect timeout.
Always read the detail string — "connect failed" and "device didn't
answer" are completely different problems and the status code will not
separate them.
What actually worked — invert the direction
The key observation is in the log above:
TCP recvhost ... state TCPMode::kClosed→Connect to IP: 0.0.0.0 Port 0
The modem auto-dials its Destination whenever serial data arrives while
closed. So instead of fighting for inbound, give it somewhere to dial:
point Destination Address at our own ach_server and the device's own
75-second attempts become device-initiated sessions the modem bridges
correctly. No race, no contention, worst case a 75-second wait.
Procedure
-
Run the rescue server on a host the modem can reach (public IP + forwarded port):
cd /home/serversdown/seismo-relay .venv/bin/python -u bridges/ach_server.py --port 12345 \ -o bridges/captures/<unit>-diag --stop-monitoring -v -
Point the modem at it — ACEmanager → Serial → Port Configuration →
Destination Address= your public IP,Destination Port= 12345. -
Wait for the call-in.
--stop-monitoringfires SUB 0x97 at step 1.5, after the handshake and before the event walk. Confirm viarescue.jsonin the session directory:{"peer": "166.246.64.226:60921", "stop_monitoring": "ok"} -
Restore the modem's Destination once you are done, then finish the device side (disable ACH, erase) through whichever channel works.
On BE12599 the first call-in landed at 20:58:11 and reported
stop_monitoring: ok; a second at 20:58:20 confirmed it. is_monitoring: false was still true 6½ hours later — the fix is durable.
Hard-won gotchas (do not re-derive)
-
Never leave the Destination pointed at a host with nothing listening. That is the worst state available: the device still dials, the modem still flips, inbound stays blocked, and nothing is delivered. An 8-minute gap with the listener down produced a spurious inbound timeout that cost another round of misdiagnosis.
-
Stopping monitoring removes your call-in channel. ACH is "after event recorded"; no new events means no new dials. The backlog sitting in memory does not re-arm it. After a successful stop the unit goes quiet and you need the modem cycled (works — produced a call-in), the scheduled daily call (BE12599 calls at 05:00:14 device-local, per §8e), or working inbound. Plan the order before you fire the stop.
-
--events-onlysilently breaks dedup. It skips the device-info step, so the serial is never read;ach_state.jsonthen keys onpeer:ephemeral_port, which is unique per connection. Every session looks like a new unit, starts from key 0, and re-downloads the same event. Four sessions on BE12599 downloaded the identical event four times and made zero progress on the backlog. Events also file asserial=UNKNOWNwith aM000…BW filename (serial_numeric 0) instead ofN599…. Do not use--events-onlywhen you intend to download anything. -
/device/events/indexreportedlifetime_count: 0on a unit with years of history. Suspected decode bug in the SUB 0x08 field offset — do not trust that number. The 88-byte payload is preserved in theraw_hexfield if someone wants to chase it. -
Memory used cross-checks the event keys exactly:
last_key − buffer_start = memory_total − memory_free. On BE12599:0x011230ec − 0x01110000 = 78,060and983,028 − 904,968 = 78,060. Useful sanity check that you are reading the keys right.
Final state (2026-09-17 ~01:30 local)
is_monitoring: false, held 6½ hours- Battery 6.76 V
- Memory 78,060 / 983,028 bytes used (8%)
first_key 01121728,last_key 011230ec— ~6.6 KB of addressable event chain, roughly 3 events- ACH still enabled — to be disabled after the backlog is preserved
- Modem Destination still pointed at tmi-dev — to be restored
- ⚠ Do not re-enable ACH until the connector is serviced. Tran is still sitting at 0.400 and the loop restarts the moment monitoring resumes.