The /device guard let every non-UM serial through before its held-line
check. FastAPI drops an undeclared `serial`, so `?serial=BE18193` on a
legacy route still ran Series-3 code at an address holding a Series-4
line -- the hole the guard exists to close. Serial-aware routes go
straight to DeviceAccess, which refuses that case itself; everything
else is checked. baud is no longer parsed (it is not in the address
key, and pydantic's coercion made "38400.0" a second way past).
Also, from the same review:
- RingWatchTransport clears its frame state on every write, so a stray
STX on an idle line cannot hide the ring that answers the next request.
- Series4Session.is_open reads _client once; held_serial() calls it
without the unit lock, and a concurrent hang-up between two reads was
an AttributeError (a 500).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44