serversdownandClaude Opus 5.5 e21d23a3f2 fix(decode): the mic dB offset is 81.938216, fitted on every count Blastware printed
The 81.9384 offset came from a window fitted on histogram intervals,
[81.9383, 81.9385], which was too high.  Every count Blastware printed
in DL2 -- 1,704 in waveform sample tables, 520 in histogram intervals,
494 histogram peaks -- leaves [81.9382058, 81.9382266]: count 129
(124.2) bounds it from below, 463 (135.2; 81.9384 prints 135.3) and 677
(138.5) from above.  One offset serves all three printing paths; no
count prints two ways once range-1 mics and psi-formatted tables are
set aside.  Fixes the mic samples and peaks that sat one digit off at a
rounding edge.  The old window's comment is kept, retracted in place.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-09 14:04:55 -05:00
..