Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
1014 lines
47 KiB
Markdown
1014 lines
47 KiB
Markdown
# Phase 3: start / stop monitoring, the first live write — Implementation Plan
|
||
|
||
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking. **Task 7 is not for a subagent**: the controller runs it at the bench, with Brian approving the send.
|
||
|
||
**Goal:** Start and stop monitoring by serial, for both series, through the safety layer. The layer covers:
|
||
- an identity check right before the write;
|
||
- the unit's state, read first;
|
||
- a dry run that returns the exact frames;
|
||
- an audit row for every attempt;
|
||
- a read-back that decides success;
|
||
- never a retried write.
|
||
|
||
Then make the project's first live send to a unit (UM20147), with Brian approving it at the bench.
|
||
|
||
**Architecture:**
|
||
|
||
- **Series 4.** `MicromateProtocol.execute(plan)` becomes the only write path.
|
||
- It transmits exactly a `WritePlan`'s frames, granting permission for that call alone.
|
||
- It refuses any plan beyond a code-reviewed ceiling, `ENABLEABLE_WRITES = {0x96, 0x97}`.
|
||
- It refuses on a connection whose replies did not carry Micromate flags.
|
||
- **The change operation**, one per series:
|
||
1. re-reads the serial;
|
||
2. reads the run state, `0x49` on Series 4 and `0x1C` on Series 3;
|
||
3. skips or refuses as appropriate;
|
||
4. audits the attempt;
|
||
5. sends;
|
||
6. polls the state until it matches or a window expires;
|
||
7. audits the result.
|
||
|
||
It returns a `ChangeResult`.
|
||
- **No retry.** `DeviceAccess` runs change operations with no retry of any kind.
|
||
- **Audit.** The table lives in SDM (`device_commands` in SeismoDb). The device side writes to it through an injected sink, so `sfm/device_access/` still imports no DB.
|
||
- **Endpoints.** The existing `POST /device/monitor/start` and `/stop` gain `serial`, `dry_run`, `even_if_already` and `caller`. Without `serial` they behave exactly as today.
|
||
|
||
**Tech Stack:** Python 3, FastAPI, pytest, SQLite.
|
||
|
||
**Spec:** `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md`, in particular:
|
||
- *The safety layer* (tiers, identity, read-back, audit table);
|
||
- *Series-4 write path* (dry run, start/stop row);
|
||
- *Testing → Bench* (the first-live-send protocol);
|
||
- **Build phases item 3, including its "Preconditions from the phase-2 final review" block**, which is binding.
|
||
|
||
## Global Constraints
|
||
|
||
- **Writes.** The only writes are `0x96`/`0x97`.
|
||
- On Series 4 they go through `MicromateProtocol.execute(plan)` only.
|
||
- On Series 3 they go through `MiniMateClient.start_monitoring()`/`stop_monitoring()`, which are unchanged.
|
||
- Nothing else may be transmitted that changes a unit.
|
||
- Tests use fakes and scripted transports only. **No task but Task 7 touches hardware**, and Task 7 sends only with Brian's explicit go-ahead in the conversation.
|
||
- **A write is never retried.**
|
||
- This covers the retry-once in `DeviceAccess._dispatch`, the TCP retry in `Series3Adapter._run`, and any loop.
|
||
- The structure must make retry impossible for a change operation. A comment saying so is not enough.
|
||
- **Identity before any write.**
|
||
- The serial is read from the unit immediately before the write: `0x15` on Series 4, `connect()` on Series 3.
|
||
- A mismatch means 409 and nothing is sent.
|
||
- **0xA2 is never sent.**
|
||
- The ceiling is `{0x96, 0x97}`.
|
||
- Raising it is a spec change.
|
||
- **The audit is mandatory.**
|
||
- A live change without an audit sink is refused (501), with nothing sent.
|
||
- Every live attempt, including a skip, gets one row.
|
||
- Dry runs are not audited: they send nothing.
|
||
- **Legacy routes are unchanged without `serial`.**
|
||
- The only permitted change: `baud` becomes `Optional[int] = Query(None)` with 38400 applied at the top of the legacy path.
|
||
- **Schema.** The `device_commands` table is additive (`CREATE TABLE IF NOT EXISTS`). At merge, the changelog must say "schema: new table, no migration, no backfill".
|
||
- **Tiers.** `sfm/device_access/` must not import `sfm.database`, `sfm.waveform_store` or `sfm.server`.
|
||
- **The suite.** Its 16 pre-existing failures stay exactly that set.
|
||
- **Branch.** Work on `feat/series4-sfm-parity`. Never commit to `main` or `dev`, do not edit `CHANGELOG.md`, and run `git push` after each commit.
|
||
- **Never move or modify `bridges/captures/`.** Port 8200 is another SFM.
|
||
- **Trailers.** Every commit message ends with:
|
||
```
|
||
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
||
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
|
||
```
|
||
|
||
## Review Focus
|
||
|
||
These are the five things most likely to bite, each with the task that tests it:
|
||
|
||
1. **A lost ack.** It must never cause a second send, whether through the held-line retry, the Series-3 cold-boot retry, or anything else (Tasks 4, 5).
|
||
2. **A different unit at the address**, for example after a modem moved. It must be refused before any write, on a fresh serial read rather than the call-up's cached serial (Tasks 4, 5).
|
||
3. **A unit that is calling home** (`0x49` = `0x03`). It is refused, with nothing sent (Task 4).
|
||
4. **A clean ack where the state never changes.** This also covers a sensor check that delays the change. It is reported as a failed change after the verify window, audited as `mismatch`, with every state value seen recorded (Tasks 4, 5).
|
||
5. **Write permission leaking.**
|
||
- After `execute()`, the same connection cannot send `0x96` again without another `execute()`.
|
||
- A plan holding `0x7E` (call-home) is refused by the ceiling.
|
||
- A connection that has seen no Micromate-flagged reply cannot execute anything (Task 1).
|
||
|
||
---
|
||
|
||
## File map
|
||
|
||
| file | change |
|
||
|---|---|
|
||
| `micromate/opcodes.py` | `ENABLEABLE_WRITES` |
|
||
| `micromate/protocol.py` | `execute(plan)`; `_send(frame, *, permit=)`; `_validate` records `last_flags` |
|
||
| `micromate/models.py` | `MicromateRunState` |
|
||
| `micromate/client.py` | `serial(refresh=)`; `read_run_state()` |
|
||
| `sfm/database.py` | `device_commands` table; `begin_device_command`, `finish_device_command`, `query_device_commands` |
|
||
| `sfm/audit.py` | **new**: `DbAudit`, the SDM sink |
|
||
| `sfm/device_access/models.py` | `ChangeResult` |
|
||
| `sfm/device_access/s4.py` | `s4_change_monitoring` |
|
||
| `sfm/device_access/s3.py` | `Series3Adapter.change_monitoring`; `_run(retry=)` |
|
||
| `sfm/device_access/access.py` | `start_monitoring`/`stop_monitoring`; `_dispatch(change=)`; `audit=`, `sleep=`, `verify_*` |
|
||
| `sfm/server.py` | serial branch on `/device/monitor/start` and `/stop`; guard paths; `GET /db/device_commands`; audit wiring |
|
||
| `tests/device_access_fakes.py` | run states, `execute`, Series-3 start/stop |
|
||
| tests | `test_micromate_execute.py`, `test_device_commands.py`, `test_device_access_change.py`, plus additions to `test_micromate_client.py` and `test_server_device_access.py` |
|
||
|
||
---
|
||
|
||
### Task 1: `execute(plan)`, the ceiling and the flags check
|
||
|
||
**Files:**
|
||
- Modify: `micromate/opcodes.py`
|
||
- Modify: `micromate/protocol.py` (`__init__`, `_validate`, `_send`, new `execute`, module docstring)
|
||
- Test: `tests/test_micromate_execute.py` (new)
|
||
|
||
**Interfaces:**
|
||
- Produces:
|
||
- `ENABLEABLE_WRITES: frozenset`
|
||
- `MicromateProtocol.execute(plan: WritePlan) -> list[MicromateFrame]`, returning the ack frames
|
||
- `MicromateProtocol.last_flags: Optional[int]`
|
||
|
||
- [ ] **Step 1: Write the failing tests.** Create `tests/test_micromate_execute.py`:
|
||
|
||
```python
|
||
"""execute(plan): the only write path -- exact frames, one call's permission, a ceiling."""
|
||
from __future__ import annotations
|
||
|
||
import os
|
||
import sys
|
||
|
||
import pytest
|
||
|
||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||
|
||
from micromate.framing import FLAGS_THOR, build_request # noqa: E402
|
||
from micromate.opcodes import ENABLEABLE_WRITES, OpcodeRefused # noqa: E402
|
||
from micromate.protocol import ACK_DATA_LEN, UnexpectedResponse # noqa: E402
|
||
from micromate.writes import ( # noqa: E402
|
||
plan_call_home_enabled, plan_start_monitoring, plan_stop_monitoring,
|
||
)
|
||
from test_micromate_protocol import frame, proto # noqa: E402
|
||
|
||
ACK_START = frame(0x69, bytes(ACK_DATA_LEN))
|
||
POLL_RSP = frame(0xA4, bytes(48))
|
||
|
||
|
||
def _ready(responses):
|
||
"""A protocol that has already seen one Micromate-flagged reply (a POLL)."""
|
||
p, t = proto([POLL_RSP] + responses)
|
||
p.poll()
|
||
t.written.clear()
|
||
return p, t
|
||
|
||
|
||
def test_the_ceiling_is_start_and_stop_only():
|
||
assert ENABLEABLE_WRITES == frozenset({0x96, 0x97})
|
||
|
||
|
||
def test_execute_sends_exactly_the_plans_frame_and_returns_the_ack():
|
||
p, t = _ready([ACK_START])
|
||
acks = p.execute(plan_start_monitoring())
|
||
assert t.written == [build_request(0x96, 0xFFFF)]
|
||
assert [a.sub for a in acks] == [0x69]
|
||
|
||
|
||
def test_permission_ends_with_the_call():
|
||
p, t = _ready([ACK_START])
|
||
p.execute(plan_start_monitoring())
|
||
with pytest.raises(OpcodeRefused):
|
||
p._send(build_request(0x96, 0xFFFF))
|
||
assert len(t.written) == 1
|
||
|
||
|
||
def test_a_plan_beyond_the_ceiling_is_refused_and_nothing_is_sent():
|
||
content = bytes(5) + b"\x05" + bytes(120)
|
||
p, t = _ready([])
|
||
with pytest.raises(OpcodeRefused, match="ceiling"):
|
||
p.execute(plan_call_home_enabled(content, False))
|
||
assert t.written == []
|
||
|
||
|
||
def test_execute_refuses_before_any_micromate_reply_has_been_seen():
|
||
p, t = proto([ACK_START])
|
||
with pytest.raises(OpcodeRefused, match="Micromate"):
|
||
p.execute(plan_start_monitoring())
|
||
assert t.written == []
|
||
|
||
|
||
def test_execute_refuses_after_a_non_micromate_flags_reply():
|
||
p, t = proto([frame(0xA4, bytes(48), flags=0x10), ACK_START], strict_checksums=False)
|
||
p.poll()
|
||
t.written.clear()
|
||
with pytest.raises(OpcodeRefused):
|
||
p.execute(plan_stop_monitoring())
|
||
assert t.written == []
|
||
|
||
|
||
def test_a_wrong_ack_sub_raises_after_one_send():
|
||
p, t = _ready([frame(0x68, bytes(ACK_DATA_LEN))]) # stop's ack, for a start
|
||
with pytest.raises(UnexpectedResponse):
|
||
p.execute(plan_start_monitoring())
|
||
assert len(t.written) == 1
|
||
|
||
|
||
def test_thor_flags_are_accepted_too():
|
||
p, t = proto([frame(0xA4, bytes(48), flags=FLAGS_THOR), frame(0x68, bytes(ACK_DATA_LEN))])
|
||
p.poll()
|
||
p.execute(plan_stop_monitoring())
|
||
assert t.written[-1] == build_request(0x97, 0xFFFF)
|
||
```
|
||
|
||
Before you write any code, make two checks:
|
||
- In `tests/test_micromate_protocol.py`, check that `ScriptedTransport` exposes `.written` as a list you can `.clear()`, and that `frame(..., flags=)` exists.
|
||
- Check that `micromate.framing` exports `FLAGS_THOR` and `FLAGS_BLASTWARE`.
|
||
|
||
If either differs, adapt the helper calls only, and say so.
|
||
|
||
- [ ] **Step 2: Run the tests and watch them fail.**
|
||
Run: `.venv/bin/python -m pytest tests/test_micromate_execute.py -q`
|
||
Expected: an ImportError on `ENABLEABLE_WRITES`.
|
||
|
||
- [ ] **Step 3: Implement.**
|
||
|
||
In `micromate/opcodes.py`, add after the tables:
|
||
|
||
```python
|
||
# The write SUBs any code may transmit at all -- through MicromateProtocol.execute,
|
||
# one call at a time. Raising this is a spec change, reviewed like one: delete
|
||
# (0xA8/0xAA), raw file writes (0x8D/0x8E -- they could reach the modem
|
||
# settings) and 0xA2 never belong here without one.
|
||
ENABLEABLE_WRITES = frozenset({0x96, 0x97})
|
||
```
|
||
|
||
In `micromate/protocol.py`:
|
||
- Imports: add `FLAGS_BLASTWARE` and `FLAGS_THOR` to the `from .framing import ...` line. Add `ENABLEABLE_WRITES` and `OpcodeRefused` to the `.opcodes` import.
|
||
- In `__init__`, add `self.last_flags: Optional[int] = None`.
|
||
- In `_validate`, before `return frame`, add `self.last_flags = frame.flags`.
|
||
- Replace `_send` with:
|
||
|
||
```python
|
||
def _send(self, frame: bytes, *, permit: frozenset = frozenset()) -> None:
|
||
# The gate sees the bytes about to go out, not the caller's intent.
|
||
# `permit` is passed only by execute(), for exactly one step.
|
||
frame = bytes(frame)
|
||
check_transmit(request_sub(frame), self._allowed_writes | permit)
|
||
log.debug("TX %d bytes: %s", len(frame), frame.hex())
|
||
self._transport.write(frame)
|
||
```
|
||
|
||
- Add after `_exchange`:
|
||
|
||
```python
|
||
def execute(self, plan) -> list:
|
||
"""Transmit a `micromate.writes.WritePlan` -- the only write path.
|
||
|
||
Permission is granted for this call alone, one step at a time, and only
|
||
for SUBs under `ENABLEABLE_WRITES`. Refuses unless the last reply on
|
||
this connection carried Micromate flags (0xC5 / 0x03). Each step's ack
|
||
is awaited before the next is sent. Never retries: a timeout raises,
|
||
and what happened is the caller's to find out by reading the unit back.
|
||
"""
|
||
beyond = plan.subs - ENABLEABLE_WRITES
|
||
if beyond:
|
||
raise OpcodeRefused(
|
||
"plan holds SUB(s) above the write ceiling: "
|
||
+ ", ".join(f"0x{s:02X}" for s in sorted(beyond)))
|
||
if self.last_flags not in (FLAGS_BLASTWARE, FLAGS_THOR):
|
||
raise OpcodeRefused(
|
||
"no Micromate-flagged reply seen on this connection -- "
|
||
"refusing to write")
|
||
acks = []
|
||
for step in plan.steps:
|
||
self._parser.reset()
|
||
self._pending.clear()
|
||
self._send(step.frame, permit=frozenset({step.sub}))
|
||
acks.append(self._recv_one(expected_sub=step.ack_sub, reset_parser=False))
|
||
return acks
|
||
```
|
||
|
||
- Module docstring: in the scope paragraph, add one sentence. `execute(plan)` is the only write path: one call's permission, at most `ENABLEABLE_WRITES`, and only on a connection that has had Micromate-flagged replies.
|
||
|
||
- [ ] **Step 4: Run the tests and watch them pass.**
|
||
Run: `.venv/bin/python -m pytest tests/test_micromate_execute.py tests/test_micromate_opcodes.py tests/test_micromate_protocol.py -q`
|
||
Expected: all pass.
|
||
|
||
- [ ] **Step 5: Full suite, then commit and push.**
|
||
Message: `feat(micromate): execute(plan) -- the only write path, one call's permission, a start/stop ceiling`.
|
||
|
||
---
|
||
|
||
### Task 2: The unit's run state and a fresh serial
|
||
|
||
**Files:**
|
||
- Modify: `micromate/models.py`, `micromate/client.py`
|
||
- Test: `tests/test_micromate_client.py` (append)
|
||
|
||
**Interfaces:**
|
||
- Produces:
|
||
- `MicromateRunState(code: int, name: str)`, where `name` is one of `"idle"` / `"monitoring"` / `"calling_home"` / `"unknown(0xNN)"`.
|
||
- `MicromateClient.read_run_state() -> MicromateRunState`
|
||
- `MicromateClient.serial(*, refresh: bool = False) -> str`
|
||
|
||
- [ ] **Step 1: Write the failing tests.** Append to `tests/test_micromate_client.py`:
|
||
|
||
```python
|
||
# ── run state (0x49) and a fresh serial ───────────────────────────────────────
|
||
|
||
import json as _json # noqa: E402
|
||
|
||
_WRITES = Path(__file__).parent / "fixtures" / "micromate-writes"
|
||
|
||
|
||
def _captured_0x49():
|
||
ex = _json.loads((_WRITES / "monitor-start-stop.json").read_text())["exchanges"]
|
||
return [bytes.fromhex(e["response_data"]) for e in ex if e["sub"] == 0x49]
|
||
|
||
|
||
def test_run_state_names_thors_captured_states():
|
||
datas = _captured_0x49()
|
||
names = []
|
||
for d in datas:
|
||
mm, _t = client([frame(0xB6, d)])
|
||
names.append(mm.read_run_state().name)
|
||
assert "idle" in names and "monitoring" in names
|
||
|
||
|
||
@pytest.mark.parametrize("code,name", [(0x00, "idle"), (0x02, "monitoring"),
|
||
(0x03, "calling_home"), (0x07, "unknown(0x07)")])
|
||
def test_run_state_names_every_value(code, name):
|
||
data = bytes(11) + bytes([code]) + bytes(4)
|
||
mm, _t = client([frame(0xB6, data)])
|
||
st = mm.read_run_state()
|
||
assert (st.code, st.name) == (code, name)
|
||
|
||
|
||
def test_serial_refresh_reads_the_unit_again():
|
||
mm, t = client([frame(0xEA, bytes(11) + b"UM20147\x00\x00\x00")])
|
||
mm._serial = "UM99999" # a stale cached serial
|
||
assert mm.serial(refresh=True) == "UM20147"
|
||
assert len(t.written) == 1
|
||
```
|
||
|
||
Before running, check two things:
|
||
- `client()` and `frame()` exist in this file with those shapes. If they differ, adapt the calls.
|
||
- The response SUBs: `0x49` gives `0xFF-0x49 = 0xB6`, and `0x15` gives `0xEA`.
|
||
|
||
- [ ] **Step 2: Run the tests and watch them fail.**
|
||
Run: `.venv/bin/python -m pytest tests/test_micromate_client.py -q -k "run_state or refresh"`
|
||
Expected: `AttributeError: ... 'read_run_state'`.
|
||
|
||
- [ ] **Step 3: Implement.**
|
||
|
||
In `micromate/models.py`, add:
|
||
|
||
```python
|
||
@dataclass(frozen=True)
|
||
class MicromateRunState:
|
||
"""`SUB 0x49` content[0]. 0x00 idle, 0x02 monitoring, 0x03 calling home
|
||
(ten of ten in the 10-14 ACH session); anything else is named, not guessed."""
|
||
code: int
|
||
name: str
|
||
```
|
||
|
||
In `micromate/client.py`:
|
||
- Import `MicromateRunState`.
|
||
- Change `serial` to `def serial(self, *, refresh: bool = False) -> str:`, with the condition `if refresh or self._serial is None:`. Document that a change operation refreshes it right before writing.
|
||
- Add after `serial`:
|
||
|
||
```python
|
||
_RUN_STATES = {0x00: "idle", 0x02: "monitoring", 0x03: "calling_home"}
|
||
|
||
def read_run_state(self) -> MicromateRunState:
|
||
"""`SUB 0x49` -> the unit's run state, with the in-call-home value kept
|
||
(connect()'s `monitoring` bool flattens 0x03 into True)."""
|
||
c = _content(self._proto.read_state())
|
||
if not c:
|
||
raise ProtocolError("0x49 state reply has no content")
|
||
code = c[_STATE_FLAG]
|
||
return MicromateRunState(code, self._RUN_STATES.get(code, f"unknown(0x{code:02X})"))
|
||
```
|
||
|
||
- [ ] **Step 4: Run the tests and watch them pass.** Then run the full suite, commit and push.
|
||
Message: `feat(micromate): read the unit's run state and refresh its serial on demand`.
|
||
|
||
---
|
||
|
||
### Task 3: The audit table and its sink
|
||
|
||
**Files:**
|
||
- Modify: `sfm/database.py`. Add to `_SCHEMA`, plus three methods.
|
||
- Create: `sfm/audit.py`
|
||
- Modify: `sfm/server.py`, for `GET /db/device_commands`
|
||
- Test: `tests/test_device_commands.py` (new)
|
||
|
||
**Interfaces:**
|
||
- Produces:
|
||
- `SeismoDb.begin_device_command(*, serial, series, address, action, tier, request: dict, caller: str) -> str`
|
||
- `SeismoDb.finish_device_command(command_id, *, outcome, verified, ack: Optional[dict], error: Optional[str]) -> None`
|
||
- `SeismoDb.query_device_commands(serial=None, limit=100) -> list[dict]`, newest first, with `request` and `ack` parsed back from JSON.
|
||
- `DbAudit(get_db: Callable[[], SeismoDb])` with `begin(**fields) -> str` and `finish(command_id, **fields)`.
|
||
|
||
- [ ] **Step 1: Write the failing tests** in `tests/test_device_commands.py`:
|
||
|
||
```python
|
||
"""The device_commands audit table: one row per change attempt, pending -> result."""
|
||
from __future__ import annotations
|
||
|
||
import os
|
||
import sys
|
||
|
||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||
|
||
from sfm.audit import DbAudit # noqa: E402
|
||
from sfm.database import SeismoDb # noqa: E402
|
||
|
||
ROW = dict(serial="UM20147", series=4, address="serial:/dev/ttyACM0",
|
||
action="start monitoring", tier="change",
|
||
request={"plan": {"steps": [{"sub": "0x96"}]}}, caller="test")
|
||
|
||
|
||
def test_a_command_is_pending_until_finished(tmp_path):
|
||
db = SeismoDb(tmp_path / "s.db")
|
||
cid = db.begin_device_command(**ROW)
|
||
row = db.query_device_commands(serial="UM20147")[0]
|
||
assert (row["id"], row["outcome"], row["verified"]) == (cid, "pending", None)
|
||
assert row["request"]["plan"]["steps"][0]["sub"] == "0x96"
|
||
db.finish_device_command(cid, outcome="sent", verified="ok",
|
||
ack={"subs": ["0x69"]}, error=None)
|
||
row = db.query_device_commands(serial="UM20147")[0]
|
||
assert (row["outcome"], row["verified"], row["ack"]) == ("sent", "ok", {"subs": ["0x69"]})
|
||
assert row["finished_ts"]
|
||
|
||
|
||
def test_the_table_survives_reopening(tmp_path):
|
||
SeismoDb(tmp_path / "s.db").begin_device_command(**ROW)
|
||
assert len(SeismoDb(tmp_path / "s.db").query_device_commands()) == 1
|
||
|
||
|
||
def test_db_audit_is_a_thin_sink(tmp_path):
|
||
db = SeismoDb(tmp_path / "s.db")
|
||
audit = DbAudit(lambda: db)
|
||
cid = audit.begin(**ROW)
|
||
audit.finish(cid, outcome="failed", verified="mismatch", ack=None, error="unit reads idle")
|
||
row = db.query_device_commands()[0]
|
||
assert (row["outcome"], row["verified"], row["error"]) == ("failed", "mismatch", "unit reads idle")
|
||
```
|
||
|
||
- [ ] **Step 2: Run them, and watch them fail** (ImportError).
|
||
|
||
- [ ] **Step 3: Implement.**
|
||
- Append to `_SCHEMA` in `sfm/database.py`:
|
||
|
||
```sql
|
||
CREATE TABLE IF NOT EXISTS device_commands (
|
||
id TEXT PRIMARY KEY,
|
||
ts TEXT NOT NULL, -- when the attempt began (UTC ISO)
|
||
finished_ts TEXT,
|
||
serial TEXT NOT NULL,
|
||
series INTEGER NOT NULL,
|
||
address TEXT NOT NULL,
|
||
action TEXT NOT NULL, -- e.g. "start monitoring"
|
||
tier TEXT NOT NULL, -- "change" | "destructive"
|
||
request TEXT, -- JSON: parameters + the planned frames (hex)
|
||
ack TEXT, -- JSON: ack summary
|
||
verified TEXT, -- "ok" | "mismatch" | "not_checked"
|
||
outcome TEXT NOT NULL, -- "pending" | "sent" | "skipped" | "failed"
|
||
error TEXT,
|
||
caller TEXT -- "webapp" | "terra-view" | "script" | ...
|
||
);
|
||
CREATE INDEX IF NOT EXISTS idx_device_commands_serial ON device_commands(serial, ts);
|
||
```
|
||
|
||
- Add the methods to `SeismoDb`. Use the existing `_new_id()` and `_connect()`, `json.dumps`/`json.loads` for `request`/`ack`, and a UTC ISO string for `ts`/`finished_ts`.
|
||
- `query_device_commands` orders by `ts DESC`.
|
||
- Create `sfm/audit.py`:
|
||
|
||
```python
|
||
"""The SDM side of the device audit: DeviceAccess calls this sink, which writes
|
||
SeismoDb.device_commands. Kept here so sfm.device_access never imports the DB."""
|
||
from __future__ import annotations
|
||
|
||
from typing import Any, Callable
|
||
|
||
|
||
class DbAudit:
|
||
def __init__(self, get_db: Callable[[], Any]) -> None:
|
||
self._get_db = get_db
|
||
|
||
def begin(self, **fields: Any) -> str:
|
||
return self._get_db().begin_device_command(**fields)
|
||
|
||
def finish(self, command_id: str, **fields: Any) -> None:
|
||
self._get_db().finish_device_command(command_id, **fields)
|
||
```
|
||
|
||
- Add `GET /db/device_commands`, with params `serial: Optional[str] = Query(None)` and `limit: int = Query(100)`. It returns `{"commands": _get_db().query_device_commands(serial, limit)}`. Put it near the other `/db/*` reads.
|
||
|
||
- [ ] **Step 4: Run the tests and watch them pass.** Then run the full suite, commit and push.
|
||
Message: `feat(sfm): device_commands audit table -- one row per change attempt`.
|
||
|
||
---
|
||
|
||
### Task 4: The Series-4 change operation and `DeviceAccess.start_monitoring` / `stop_monitoring`
|
||
|
||
**Files:**
|
||
- Modify: `sfm/device_access/models.py` (add `ChangeResult`), `sfm/device_access/s4.py` (add `s4_change_monitoring`), `sfm/device_access/access.py`, `sfm/device_access/__init__.py`
|
||
- Modify: `tests/device_access_fakes.py`
|
||
- Test: `tests/test_device_access_change.py` (new)
|
||
|
||
**Interfaces:**
|
||
- Consumes: Task 1 (`execute`), Task 2 (`read_run_state`, `serial(refresh=)`), and the phase-2 `plan_start_monitoring`/`plan_stop_monitoring`.
|
||
- Produces:
|
||
- `ChangeResult`, with the fields shown below.
|
||
- `DeviceAccess(..., audit=None, sleep=time.sleep, verify_timeout_s=60.0, verify_interval_s=2.0)`
|
||
- `DeviceAccess.start_monitoring(address, serial, *, dry_run=False, even_if_already=False, caller="api") -> ChangeResult`, and the same for `stop_monitoring`.
|
||
|
||
- [ ] **Step 1: Extend the fakes.** In `tests/device_access_fakes.py`, give `FakeMicromateClient` these keyword arguments:
|
||
- `run_states=None`, a list of codes consumed one per `read_run_state()` call, with the last one repeating; it defaults to `[0x00]`;
|
||
- `serial_reported=None`, defaulting to `serial`;
|
||
- `execute_error=None`.
|
||
|
||
Then add these methods:
|
||
|
||
```python
|
||
def serial(self, *, refresh=False):
|
||
self._step("serial")
|
||
return self.serial_reported
|
||
|
||
def read_run_state(self):
|
||
from micromate.models import MicromateRunState
|
||
self._step("read_run_state")
|
||
code = self.run_states.pop(0) if len(self.run_states) > 1 else self.run_states[0]
|
||
names = {0x00: "idle", 0x02: "monitoring", 0x03: "calling_home"}
|
||
return MicromateRunState(code, names.get(code, f"unknown(0x{code:02X})"))
|
||
```
|
||
|
||
On `_FakeProtocol`, add:
|
||
|
||
```python
|
||
def execute(self, plan):
|
||
self._owner._step("execute")
|
||
self._owner.executed.append(plan)
|
||
if self._owner.execute_error is not None:
|
||
raise self._owner.execute_error
|
||
return [type("Ack", (), {"sub": s.ack_sub, "data": bytes(11)})() for s in plan.steps]
|
||
```
|
||
|
||
Also add `self.executed = []` to `FakeMicromateClient.__init__`.
|
||
|
||
- [ ] **Step 2: Write the failing tests** in `tests/test_device_access_change.py`:
|
||
|
||
```python
|
||
"""Start/stop through the safety layer: identity, state, dry run, audit, read-back, no retry."""
|
||
from __future__ import annotations
|
||
|
||
import os
|
||
import sys
|
||
|
||
import pytest
|
||
|
||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||
|
||
import micromate.protocol as mm_proto # noqa: E402
|
||
from device_access_fakes import FakeMicromateClient # noqa: E402
|
||
from sfm.device_access.access import DeviceAccess # noqa: E402
|
||
from sfm.device_access.errors import ( # noqa: E402
|
||
CallHomeInProgress, NotSupported, WrongUnit,
|
||
)
|
||
from sfm.device_access.models import UnitAddress # noqa: E402
|
||
|
||
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
|
||
|
||
|
||
class Audit:
|
||
def __init__(self):
|
||
self.rows = {}
|
||
|
||
def begin(self, **f):
|
||
cid = f"c{len(self.rows) + 1}"
|
||
self.rows[cid] = dict(f, outcome="pending")
|
||
return cid
|
||
|
||
def finish(self, cid, **f):
|
||
self.rows[cid].update(f)
|
||
|
||
|
||
def access(fake, audit="default"):
|
||
return DeviceAccess(s4_client_factory=lambda a, **kw: fake, start_reaper=False,
|
||
audit=Audit() if audit == "default" else audit,
|
||
sleep=lambda s: None, verify_timeout_s=6.0, verify_interval_s=2.0)
|
||
|
||
|
||
def test_a_dry_run_returns_the_exact_frames_and_sends_nothing():
|
||
fake = FakeMicromateClient(run_states=[0x00])
|
||
da = access(fake)
|
||
r = da.start_monitoring(ADDR, "UM20147", dry_run=True)
|
||
assert (r.dry_run, r.sent, r.outcome, r.state_before) == (True, False, "dry_run", "idle")
|
||
assert r.plan["steps"][0]["frame"] == "41021010009600ffff00000000000000000000a403"
|
||
assert fake.executed == [] and da._audit.rows == {}
|
||
|
||
|
||
def test_start_sends_once_and_verifies_by_reading_back():
|
||
fake = FakeMicromateClient(run_states=[0x00, 0x00, 0x02])
|
||
da = access(fake)
|
||
r = da.start_monitoring(ADDR, "UM20147")
|
||
assert (r.sent, r.outcome, r.verified, r.state_after) == (True, "sent", "ok", "monitoring")
|
||
assert len(fake.executed) == 1
|
||
row = da._audit.rows[r.audit_id]
|
||
assert (row["outcome"], row["verified"], row["action"]) == ("sent", "ok", "start monitoring")
|
||
assert r.detail["states_seen"][-1] == "monitoring"
|
||
|
||
|
||
def test_already_in_state_is_skipped_and_audited_as_skipped():
|
||
fake = FakeMicromateClient(run_states=[0x02])
|
||
da = access(fake)
|
||
r = da.start_monitoring(ADDR, "UM20147")
|
||
assert (r.sent, r.outcome) == (False, "skipped") and fake.executed == []
|
||
assert da._audit.rows[r.audit_id]["outcome"] == "skipped"
|
||
|
||
|
||
def test_even_if_already_sends_anyway():
|
||
fake = FakeMicromateClient(run_states=[0x02])
|
||
r = access(fake).start_monitoring(ADDR, "UM20147", even_if_already=True)
|
||
assert r.sent and len(fake.executed) == 1
|
||
|
||
|
||
def test_a_unit_calling_home_is_refused_and_nothing_is_sent():
|
||
fake = FakeMicromateClient(run_states=[0x03])
|
||
with pytest.raises(CallHomeInProgress):
|
||
access(fake).stop_monitoring(ADDR, "UM20147")
|
||
assert fake.executed == []
|
||
|
||
|
||
def test_a_different_unit_on_the_fresh_serial_read_is_refused_before_writing():
|
||
fake = FakeMicromateClient(serial_reported="UM12947")
|
||
with pytest.raises(WrongUnit):
|
||
access(fake).start_monitoring(ADDR, "UM20147")
|
||
assert fake.executed == []
|
||
|
||
|
||
def test_a_live_change_without_an_audit_sink_is_refused():
|
||
fake = FakeMicromateClient()
|
||
with pytest.raises(NotSupported, match="audit"):
|
||
access(fake, audit=None).start_monitoring(ADDR, "UM20147")
|
||
assert fake.executed == []
|
||
|
||
|
||
def test_a_clean_ack_but_no_state_change_is_a_failed_change():
|
||
fake = FakeMicromateClient(run_states=[0x00]) # never leaves idle
|
||
da = access(fake)
|
||
r = da.start_monitoring(ADDR, "UM20147")
|
||
assert (r.outcome, r.verified, r.state_after) == ("failed", "mismatch", "idle")
|
||
assert len(r.detail["states_seen"]) == 4 # 6 s window / 2 s + the first read
|
||
assert da._audit.rows[r.audit_id]["verified"] == "mismatch"
|
||
|
||
|
||
def test_a_lost_ack_is_never_retried():
|
||
fake = FakeMicromateClient(run_states=[0x00, 0x02],
|
||
execute_error=mm_proto.TimeoutError("no ack"))
|
||
da = access(fake)
|
||
r = da.start_monitoring(ADDR, "UM20147")
|
||
assert len(fake.executed) == 1
|
||
assert (r.outcome, r.state_after) == ("failed", "monitoring")
|
||
assert "no ack" in r.detail["error"]
|
||
assert da._audit.rows[r.audit_id]["outcome"] == "failed"
|
||
|
||
|
||
def test_a_change_on_a_dropped_held_line_is_not_retried():
|
||
fake = FakeMicromateClient(run_states=[0x00])
|
||
da = access(fake)
|
||
da.status(ADDR, "UM20147") # hold the line
|
||
fake.fail = [mm_proto.TimeoutError("peer gone")] # next call fails
|
||
with pytest.raises(Exception):
|
||
da.start_monitoring(ADDR, "UM20147")
|
||
assert fake.executed == [] # never reached the write, never re-tried
|
||
```
|
||
|
||
Before running, check `FakeMicromateClient.status`'s call sequence, so the `fail` queue in the last test hits the first call of the change. Adapt the queue position if needed, and say so in the report.
|
||
|
||
- [ ] **Step 3: Run the tests and watch them fail** (AttributeError: `start_monitoring`).
|
||
|
||
- [ ] **Step 4: Implement.**
|
||
|
||
`sfm/device_access/models.py`, append:
|
||
|
||
```python
|
||
@dataclass
|
||
class ChangeResult:
|
||
"""The outcome of a change request. `outcome`: "dry_run" | "skipped" | "sent" |
|
||
"failed". `verified`: "ok" | "mismatch" | "not_checked". `plan` is the exact
|
||
frames planned (dry run) or sent."""
|
||
serial: str
|
||
series: int
|
||
action: str
|
||
dry_run: bool
|
||
sent: bool
|
||
outcome: str
|
||
verified: str
|
||
state_before: Optional[str]
|
||
state_after: Optional[str]
|
||
audit_id: Optional[str]
|
||
plan: Dict[str, Any] = field(default_factory=dict)
|
||
detail: Dict[str, Any] = field(default_factory=dict)
|
||
```
|
||
|
||
`sfm/device_access/s4.py`, add:
|
||
- imports: `from micromate.writes import plan_start_monitoring, plan_stop_monitoring`, plus `ChangeResult`, `CallHomeInProgress`, `NotSupported` and `WrongUnit` where not already imported;
|
||
- the function below. It is a plain function; `DeviceAccess` calls it inside `session.run`.
|
||
|
||
```python
|
||
def s4_change_monitoring(client: Any, serial: str, *, start: bool, dry_run: bool,
|
||
even_if_already: bool, audit: Any, address: UnitAddress,
|
||
caller: str, sleep: Callable[[float], None],
|
||
verify_timeout_s: float, verify_interval_s: float) -> ChangeResult:
|
||
"""Identity -> state -> (dry run | skip | audit -> send -> read back -> audit)."""
|
||
action = "start monitoring" if start else "stop monitoring"
|
||
want = "monitoring" if start else "idle"
|
||
|
||
reported = normalise_serial(client.serial(refresh=True))
|
||
if reported != serial:
|
||
raise WrongUnit(f"asked for {serial} but {reported} answered at {address.key} -- "
|
||
"nothing sent")
|
||
before = client.read_run_state()
|
||
if before.name == "calling_home":
|
||
raise CallHomeInProgress(_RING_MESSAGE)
|
||
plan = plan_start_monitoring() if start else plan_stop_monitoring()
|
||
base = dict(serial=serial, series=4, action=action, plan=plan.describe(),
|
||
state_before=before.name)
|
||
|
||
if dry_run:
|
||
return ChangeResult(dry_run=True, sent=False, outcome="dry_run",
|
||
verified="not_checked", state_after=None, audit_id=None, **base)
|
||
if audit is None:
|
||
raise NotSupported("no audit log is configured -- SFM refuses to change a unit "
|
||
"without one (nothing sent)")
|
||
request = {"plan": plan.describe(), "even_if_already": even_if_already}
|
||
cid = audit.begin(serial=serial, series=4, address=address.key, action=action,
|
||
tier="change", request=request, caller=caller)
|
||
if before.name == want and not even_if_already:
|
||
audit.finish(cid, outcome="skipped", verified="not_checked", ack=None,
|
||
error=f"already {want}")
|
||
return ChangeResult(dry_run=False, sent=False, outcome="skipped",
|
||
verified="not_checked", state_after=before.name,
|
||
audit_id=cid, detail={"reason": f"the unit is already {want}"}, **base)
|
||
|
||
try:
|
||
acks = client.protocol.execute(plan)
|
||
except Exception as exc: # noqa: BLE001 -- recorded, never retried
|
||
after = _try_run_state(client)
|
||
audit.finish(cid, outcome="failed", verified="not_checked", ack=None,
|
||
error=f"no clean ack: {exc}")
|
||
if after is None:
|
||
raise # the line is suspect: let _exchange hang up
|
||
return ChangeResult(dry_run=False, sent=True, outcome="failed",
|
||
verified="not_checked", state_after=after, audit_id=cid,
|
||
detail={"error": f"no clean ack: {exc}"}, **base)
|
||
|
||
ack = {"subs": [f"0x{a.sub:02X}" for a in acks], "data": [bytes(a.data).hex() for a in acks]}
|
||
seen = [before.name]
|
||
polls = int(verify_timeout_s // verify_interval_s)
|
||
for _ in range(polls):
|
||
sleep(verify_interval_s)
|
||
seen.append(client.read_run_state().name)
|
||
if seen[-1] == want:
|
||
break
|
||
ok = seen[-1] == want
|
||
audit.finish(cid, outcome="sent" if ok else "failed", verified="ok" if ok else "mismatch",
|
||
ack=ack, error=None if ok else f"unit reads {seen[-1]}, expected {want}")
|
||
return ChangeResult(dry_run=False, sent=True, outcome="sent" if ok else "failed",
|
||
verified="ok" if ok else "mismatch", state_after=seen[-1],
|
||
audit_id=cid, detail={"states_seen": seen, "ack": ack}, **base)
|
||
|
||
|
||
def _try_run_state(client: Any) -> Optional[str]:
|
||
try:
|
||
return client.read_run_state().name
|
||
except Exception: # noqa: BLE001
|
||
return None
|
||
```
|
||
|
||
Check the poll count against the test's expectation. With a 6 s window and a 2 s interval, the loop gives 3 reads after the first, so 4 in total. Keep the test and the code consistent. If you change one, say which in the report.
|
||
|
||
In `sfm/device_access/access.py`:
|
||
- Constructor: add the keyword arguments `audit: Any = None`, `sleep: Callable[[float], None] = time.sleep`, `verify_timeout_s: float = 60.0` and `verify_interval_s: float = 2.0`, and store them, with `self._audit = audit`.
|
||
- Add `change: bool = False` to `_dispatch`. Make the Series-4 retry condition `if was_held and not change and isinstance(exc, (NoAnswer, ConnectFailed)):`, and update the comment: a change is never retried, by construction.
|
||
- Add the public methods:
|
||
|
||
```python
|
||
def start_monitoring(self, address: UnitAddress, serial: str, *, dry_run: bool = False,
|
||
even_if_already: bool = False, caller: str = "api") -> ChangeResult:
|
||
return self._change_monitoring(address, serial, start=True, dry_run=dry_run,
|
||
even_if_already=even_if_already, caller=caller)
|
||
|
||
def stop_monitoring(self, address: UnitAddress, serial: str, *, dry_run: bool = False,
|
||
even_if_already: bool = False, caller: str = "api") -> ChangeResult:
|
||
return self._change_monitoring(address, serial, start=False, dry_run=dry_run,
|
||
even_if_already=even_if_already, caller=caller)
|
||
|
||
def _change_monitoring(self, address, serial, *, start, dry_run, even_if_already, caller):
|
||
kw = dict(start=start, dry_run=dry_run, even_if_already=even_if_already,
|
||
audit=self._audit, address=address, caller=caller, sleep=self._sleep,
|
||
verify_timeout_s=self._verify_timeout_s,
|
||
verify_interval_s=self._verify_interval_s)
|
||
return self._dispatch(
|
||
address, serial,
|
||
lambda a, s: self._s3.change_monitoring(a, s, **kw),
|
||
lambda c, s: s4_change_monitoring(c, s, **kw),
|
||
change=True)
|
||
```
|
||
|
||
`self._s3.change_monitoring` arrives in Task 5. Until then, add a stub on `Series3Adapter` that raises `NotSupported("Series 3 start/stop through DeviceAccess arrives in Task 5")`, so this task's tests run.
|
||
- Export `ChangeResult` from `__init__.py`.
|
||
|
||
- [ ] **Step 5: Run the tests and watch them pass.**
|
||
Run: `.venv/bin/python -m pytest tests/test_device_access_change.py tests/test_device_access*.py -q`
|
||
Expected: all pass.
|
||
|
||
- [ ] **Step 6: Full suite, then commit and push.**
|
||
Message: `feat(sfm): start/stop monitoring for Series 4 -- identity, state, dry run, audit, read-back, never retried`.
|
||
|
||
---
|
||
|
||
### Task 5: The Series-3 change operation
|
||
|
||
**Files:**
|
||
- Modify: `sfm/device_access/s3.py`
|
||
- Modify: `tests/device_access_fakes.py`
|
||
- Test: `tests/test_device_access_change.py` (append)
|
||
|
||
**Interfaces:**
|
||
- Produces:
|
||
- `Series3Adapter.change_monitoring(address, serial, **kw) -> ChangeResult`, with the same keyword arguments as `s4_change_monitoring`.
|
||
- `Series3Adapter._run(address, fn, timeout=None, retry=True)`
|
||
|
||
- [ ] **Step 1: Extend the fakes.** On `FakeMiniMateClient`:
|
||
- add the keyword arguments `monitor_states=None` (a list of bools consumed by `get_monitor_status()`, with the last one repeating; it defaults to `[monitoring]`) and `write_error=None`;
|
||
- add `self.writes = []`;
|
||
- add `start_monitoring()` and `stop_monitoring()`. Each `_step`s, appends its name to `writes`, and raises `write_error` if one is set;
|
||
- make `get_monitor_status()` consume `monitor_states`.
|
||
|
||
- [ ] **Step 2: Write the failing tests** (append to `tests/test_device_access_change.py`):
|
||
|
||
```python
|
||
# ── Series 3 ──────────────────────────────────────────────────────────────────
|
||
|
||
import minimateplus.protocol as mmp_proto # noqa: E402
|
||
from device_access_fakes import FakeMiniMateClient # noqa: E402
|
||
|
||
TCP3 = UnitAddress(host="10.0.0.6", tcp_port=12345, port=None, baud=None)
|
||
|
||
|
||
def access3(fake, audit="default"):
|
||
seen = []
|
||
|
||
def factory(a, **kw):
|
||
seen.append(kw)
|
||
return fake
|
||
da = DeviceAccess(s3_client_factory=factory, start_reaper=False,
|
||
audit=Audit() if audit == "default" else audit,
|
||
sleep=lambda s: None, verify_timeout_s=6.0, verify_interval_s=2.0)
|
||
da.factory_calls = seen
|
||
return da
|
||
|
||
|
||
def test_series3_dry_run_returns_its_own_frame_and_sends_nothing():
|
||
fake = FakeMiniMateClient(monitor_states=[False])
|
||
r = access3(fake).start_monitoring(TCP3, "BE18193", dry_run=True)
|
||
assert (r.series, r.outcome, r.state_before) == (3, "dry_run", "idle")
|
||
assert r.plan["steps"][0]["sub"] == "0x96" and fake.writes == []
|
||
|
||
|
||
def test_series3_start_is_verified_by_monitor_status():
|
||
fake = FakeMiniMateClient(monitor_states=[False, False, True])
|
||
da = access3(fake)
|
||
r = da.start_monitoring(TCP3, "BE18193")
|
||
assert (r.outcome, r.verified, r.state_after) == ("sent", "ok", "monitoring")
|
||
assert fake.writes == ["start_monitoring"]
|
||
|
||
|
||
def test_series3_wrong_unit_is_refused_before_writing():
|
||
fake = FakeMiniMateClient(serial="BE11529")
|
||
with pytest.raises(WrongUnit):
|
||
access3(fake).stop_monitoring(TCP3, "BE18193")
|
||
assert fake.writes == []
|
||
|
||
|
||
def test_series3_a_lost_ack_is_never_retried_even_over_tcp():
|
||
fake = FakeMiniMateClient(monitor_states=[False, True],
|
||
write_error=mmp_proto.TimeoutError("no ack"))
|
||
da = access3(fake)
|
||
r = da.start_monitoring(TCP3, "BE18193")
|
||
assert fake.writes == ["start_monitoring"] # one send, no cold-boot retry
|
||
assert r.outcome == "failed" and r.state_after == "monitoring"
|
||
```
|
||
|
||
- [ ] **Step 3: Run them and watch them fail** (the Task 4 stub raises NotSupported).
|
||
|
||
- [ ] **Step 4: Implement.** In `sfm/device_access/s3.py`:
|
||
- `_run` gains `retry: bool = True`. In its `except NoAnswer:`, add `if not retry or not address.host: raise`.
|
||
- Replace the stub with `change_monitoring`. It follows `s4_change_monitoring` step for step:
|
||
1. `info = client.connect()` and `self._check(info.serial, serial, address)`. This is the fresh identity read: `connect()` reads `0x15`.
|
||
2. `before = "monitoring" if client.get_monitor_status().is_monitoring else "idle"`.
|
||
3. The dry-run plan, built from `minimateplus.framing.build_bw_write_frame(SUB_START_MONITORING or SUB_STOP_MONITORING, b"")`. Take the SUB constants from `minimateplus.protocol`. Shape it as `{"action", "sends_nothing": True, "steps": [{"sub": "0x96", "what": ..., "offset": "0x0000", "data_len": 0, "expect_ack": "0x69", "frame": <hex>}]}`, the same shape as Series 4.
|
||
4. The audit, skip, send (`client.start_monitoring()`/`stop_monitoring()`), read-back poll and audit-finish logic, identical in shape to Series 4. There is no `calling_home` state on Series 3.
|
||
5. Call `self._run(address, op, timeout=S3_EVENT_TIMEOUT, retry=False)`.
|
||
- Factor the shared poll/audit tail out of `s4_change_monitoring` into a helper in a new module, `sfm/device_access/change.py`, if that keeps both short. Do not duplicate 40 lines.
|
||
|
||
- [ ] **Step 5: Run the tests and watch them pass**, then the full suite, then commit and push.
|
||
Message: `feat(sfm): start/stop monitoring for Series 3 through the same safety layer`.
|
||
|
||
---
|
||
|
||
### Task 6: The endpoints
|
||
|
||
**Files:**
|
||
- Modify: `sfm/server.py`. Change `device_monitor_start` and `device_monitor_stop`, add to `_SERIAL_AWARE_PATHS`, and build `_device_access_instance` with `audit=DbAudit(_get_db)`.
|
||
- Test: `tests/test_server_device_access.py` (append)
|
||
|
||
**Interfaces:**
|
||
- Produces: `POST /device/monitor/start` and `POST /device/monitor/stop`. Each gains `serial`, `dry_run: bool = False`, `even_if_already: bool = False` and `caller: Optional[str] = None`, and returns the `ChangeResult` as JSON. The HTTP status:
|
||
|
||
| case | status |
|
||
|---|---|
|
||
| dry_run, skipped, sent and verified ok | 200 |
|
||
| failed with `verified` "mismatch" | **409** |
|
||
| any other failed | **502** |
|
||
| a `DeviceError` | its own status |
|
||
|
||
- [ ] **Step 1: Write the failing tests.** Append direct-call handler tests. Build each `DeviceAccess` with the fakes and an `Audit` recorder, and monkeypatch `srv._device_access_instance`. Cover:
|
||
- a dry run returns 200 with the frame;
|
||
- a live start that verifies returns 200;
|
||
- a mismatch returns 409 with the body still holding `states_seen`;
|
||
- a lost ack where the state read back fine returns 502;
|
||
- `/device/monitor/start` without `serial` runs the legacy code unchanged. Use the same "legacy untouchable" pattern as the existing events test: monkeypatch `_device_access` to raise, and monkeypatch `_build_client` to raise a sentinel.
|
||
- Add both paths to the guard test's "allowed" list.
|
||
|
||
- [ ] **Step 2: Run them and watch them fail.**
|
||
|
||
- [ ] **Step 3: Implement.**
|
||
- **`baud` parameter:** `baud` becomes `Optional[int] = Query(None)` on both routes.
|
||
- **New parameters:** append `serial: Optional[str] = Query(None, description=_SERIAL_DOC)`, `dry_run: bool = Query(False)`, `even_if_already: bool = Query(False)` and `caller: Optional[str] = Query(None)`.
|
||
- **Docstring:** add a paragraph. With `serial`: identity check, state first, dry run, audit, read-back, never retried. The response is the ChangeResult. Without `serial`: the legacy behaviour below.
|
||
- **Serial branch:** put it first in each route, then `baud = 38400 if baud is None else baud` before the legacy code.
|
||
|
||
```python
|
||
if serial:
|
||
return _change_response(lambda: _device_access().start_monitoring(
|
||
_unit_address(port, baud, host, tcp_port), serial, dry_run=dry_run,
|
||
even_if_already=even_if_already, caller=caller or "api"))
|
||
```
|
||
|
||
- **The helper:**
|
||
|
||
```python
|
||
def _change_response(fn) -> JSONResponse:
|
||
try:
|
||
result = fn()
|
||
except DeviceError as exc:
|
||
raise HTTPException(status_code=exc.http_status, detail=str(exc)) from exc
|
||
status = 200
|
||
if result.outcome == "failed":
|
||
status = 409 if result.verified == "mismatch" else 502
|
||
return JSONResponse(status_code=status, content=dataclasses.asdict(result))
|
||
```
|
||
|
||
- **Wiring:** `_device_access_instance = DeviceAccess(audit=DbAudit(_get_db))`. Import `DbAudit` from `sfm.audit`.
|
||
- **Guard:** add `"/device/monitor/start"` and `"/device/monitor/stop"` to `_SERIAL_AWARE_PATHS`.
|
||
|
||
- [ ] **Step 4: Run the tests, watch them pass, then the full suite, commit and push.**
|
||
Message: `feat(sfm): start/stop monitoring by serial -- dry run, audit, read-back`.
|
||
|
||
---
|
||
|
||
### Task 7: The first live send, at the bench (controller and Brian, not a subagent)
|
||
|
||
**Run only with Brian present and saying go.** UM20147 is on `/dev/ttyACM0` (`sg dialout`). SFM runs on port 8299 with a scratch database, through the phase-1b launcher pattern (patch `_DEFAULT_DB_PATH`, write a PID file, start and stop in one command). Log `micromate.protocol` at DEBUG, so every TX/RX frame is recorded.
|
||
|
||
1. **Dry run, both actions:**
|
||
- `POST /device/monitor/start?serial=UM20147&port=/dev/ttyACM0&dry_run=true`
|
||
- the same for `/stop`
|
||
|
||
Show Brian the state and the exact frame. It must be `41021010009600ffff00000000000000000000a403` for start, byte-identical to THOR's.
|
||
2. **Brian says go:** a live `POST /device/monitor/start`. Record:
|
||
- the HTTP status and body;
|
||
- the debug TX/RX lines;
|
||
- `states_seen`, including any sensor-check interval;
|
||
- the `device_commands` row.
|
||
|
||
Confirm on the unit's screen that it is monitoring.
|
||
3. **Brian says go:** a live `POST /device/monitor/stop`. Record the same, and confirm on the screen.
|
||
4. **Optional, if Brian wants to settle the open question:**
|
||
- Stop again with `even_if_already=true` while idle. This records the ack of a "stop while stopped" (spec: open bench question).
|
||
- The plain stop-while-idle path is a skip and sends nothing.
|
||
5. **Record the results:**
|
||
- **`docs/micromate_protocol_reference.md`:** a dated, graded entry with the frames, acks, states and timings. It answers "does `0x49` reflect the change immediately", and records the sensor-check delay if any.
|
||
- **`CLAUDE.md`:** retract, in place, "No command has ever been originated against a unit by this project". Add: the first commands were `0x96`/`0x97` to UM20147 on <date>, sent by SFM at the bench with Brian's approval.
|
||
- **Trilium:** a dev-log entry.
|
||
|
||
## Self-review notes
|
||
|
||
- **Spec coverage.** Build phases item 3 and its six preconditions:
|
||
- per-call permission: Task 1;
|
||
- ceiling: Task 1;
|
||
- never retry: Tasks 4 and 5;
|
||
- plan built inside the lock right before sending, with no stored dry-run plan ever sent: Task 4, where the plan is built inside the dispatched operation;
|
||
- read state first: Tasks 4 and 5;
|
||
- Micromate flags: Task 1.
|
||
|
||
The safety layer's identity check, audit table and read-back are Tasks 3–5. The dry run is Tasks 4–6. The bench protocol is Task 7.
|
||
- **Not in phase 3:** call-home writes (phase 4), setup push (phase 5), the dry-run digest echo (optional in the spec, deferred), Series-3 held sessions, and the blind-stop-tool decision (Brian).
|
||
- **The verify window.** It is 60 s by default. Series 3's sensor check took about 40 s (4-8-26). Series 4's is unmeasured, and Task 7 measures it.
|