# SFM phase 1c — the webapp on the serial-based endpoints, plus wrong-series safeguards
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** The SFM standalone page (`sfm/sfm_webapp.html`) drives both series through the serial-based device endpoints. In addition, no MiniMate-only write or erase can reach a unit that has not identified itself as Series 3.
**Architecture:**
- **Server:** one helper refuses the legacy Series-3 write/erase routes unless the unit's own serial (read on the same connection) says Series 3.
- **Page:** the series routing and button rules live in a marked block of pure functions, tested through Node. The DOM wiring calls those functions and nothing else to build a `/device/` URL or decide a button's state.
**Tech Stack:** Python 3.10 / FastAPI (`sfm/server.py`), vanilla JS in one HTML file, pytest. Node 20 (`~/.local/bin/node`) runs the page-logic tests.
**Spec:** `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` covers "The webapp", "Scope: the parity table" rows 1–5 and 7, and "Build phases" 1c. The design agreed with Brian on 2026-10-28 is recorded in the Global Constraints below.
## Global Constraints
- Work in worktree `~/seismo-relay-parity`, on branch `feat/series4-sfm-parity`. Never commit to `main`. Check with `git branch --show-current` before every commit.
- Run tests with `/home/serversdown/seismo-relay/.venv/bin/python -m pytest -q -p no:cacheprovider`. The baseline is **16 known failures** (15 in `test_bw_ascii_report.py`, 1 in `test_event_file_io.py`). Read the failure list before committing. A `pytest | tail` exits 0.
- **Serial optional:** with a serial, the Live tabs use the serial-based endpoints: `/device/info`, `/device/monitor/status`, `/device/settings`, `/device/events`, `POST /device/events/download`, and `POST /device/monitor/start|stop` (all with `serial=`), plus `POST /device/hangup?host=&tcp_port=`. With the serial blank, every read behaves exactly as today.
- **Series comes from the unit's reply.** The badge and every series-specific control follow the `series` field of the last `/device/info` reply, and only if its `serial` equals the typed one. A typed serial alone never enables a series-specific control.
- **Write buttons:**
- Start/stop use the audited serial path for both series.
- Config write and Call-Home write are **disabled for both series**. Their tooltips read exactly "Coming in phase 5 (#46)" and "Coming in phase 4".
- Diagnostics (erase, rescue, slow drip, blind stop) is enabled only when the confirmed series is 3.
- Hang up is shown only when the confirmed series is 4.
- **Start feedback:** while a start is in flight, show "Starting — the unit runs its sensor check first (about 35 s)". The legacy 60-second `_pollMonitorConfirm` loop is not used in serial mode.
- **Results are reported as SFM returned them:** outcome, verified, state before → after, and the first 8 characters of the audit id. HTTP error `detail` strings are shown verbatim.
- **Speed (Brian):** no new request may be added to a path unless the plan says why. The server identity check reuses the serial that `connect()` already reads. On `rescue` and `POST /device/call_home` it adds exactly one SUB 0x15 read.
- No codec, store or DB change. The legacy `/device/*` routes keep their URLs and parameters (a new optional `serial` is added).
## Review Focus
1. **A typed `BE…` serial at an address that holds a Micromate.** The server must refuse every guarded route with 409 and send no write. In the page, Diagnostics stays disabled until `/device/info` answers Series 3. Pinned by Task 1 (`test_guarded_route_refuses_a_unit_that_answers_as_series4`) and Task 2 (`controls: typed serial is not confirmation`).
2. **The serial is edited after a successful identify.** The confirmation must stop counting the moment the typed serial no longer matches. Pinned by Task 2 (`controls: confirmation drops when the serial changes`).
3. **Lower-case or space-padded serials** (`" be9441 "`) are normalised the same way the server normalises them. Pinned by Task 2 (`seriesFromSerial` and `unitQuery` cases).
4. **A start that times out (504) or reads back a mismatch (409).** The page must show the server's detail and the audit id, never "started". Pinned by Task 2 (`changeSummary` cases for `failed`/`mismatch`) and Task 5 (an error-path render).
5. **A download that is already stored** (`inserted: false`) is reported as "already stored" and still opens the stored event. Pinned by Task 2 (`downloadSummary`).
---
### Task 1: Server — legacy Series-3 writes refuse a unit that isn't Series 3
**Files:**
- Modify: `sfm/server.py`:
- `device_config` (~1107), `device_events_erase` (~1427), `device_rescue` (~1763), the `device_call_home` POST (~2066);
- `device_config_project` passes `serial` through.
- Modify: `minimateplus/client.py`: add `MiniMateClient.read_serial()`.
- Test: create `tests/test_server_series3_guard.py`.
**Interfaces:**
- Produces: `MiniMateClient.read_serial(self) -> str`. Requires an open, polled session. It runs the SUB 0x15 read (`self._require_proto().read(SUB_SERIAL_NUMBER)`) and returns `_decode_serial_number(...).serial`.
- Produces: `sfm.server._require_series3(unit_serial: Optional[str], expected: Optional[str]) -> None`. It raises `HTTPException(409, detail)` when either:
- `series_for_serial(unit_serial)` is not 3 (an unknown serial counts as not 3), with detail `f"the unit at this address answers as {unit_serial!r}, not a Series-3 unit -- nothing sent"`; or
- `expected` is given and `normalise_serial(expected) != normalise_serial(unit_serial)`, with detail `f"the unit at this address is {unit_serial}, not {expected} -- nothing sent"`.
- Each guarded route gains `serial: Optional[str] = Query(None, description=_SERIAL_DOC)`. It calls the guard right after it knows the unit's serial, and before its first write:
- `device_config` and `device_events_erase`: `info = client.connect()` → `_require_series3(info.serial, serial)`;
- `device_rescue` and `device_call_home` (POST): after `client.poll()` → `_require_series3(client.read_serial(), serial)`.
- Not guarded, and each gets a one-line comment saying why: legacy `monitor/start|stop`, `stop_monitoring_blind`, `stop_monitoring_slow_drip`, `stop_monitoring_spam`. They send only `0x96`/`0x97`, which mean the same on both series (measured 2026-10-25/27), and the rescue tools must work on a unit too wedged to answer.
- [ ] **Step 1: Write the failing tests** in `tests/test_server_series3_guard.py`. Use `monkeypatch.setattr(srv, "_build_client", factory)` as `tests/test_server_device_access.py:398` does. The fake client records every call:
- `test_guarded_route_refuses_a_unit_that_answers_as_series4[route]`: parametrise over the four routes. The fake's `connect()` returns a `DeviceInfo(serial="UM20147")`, or its `read_serial()` returns `"UM20147"`. Assert `HTTPException.status_code == 409`, and that the recorded calls contain no write method (`delete_all_events`, `apply_config`, `set_call_home_config`, `stop_monitoring`).
- `test_guarded_route_refuses_a_different_series3_unit`: the unit answers `"BE9441"`, the request names `serial="BE12599"`, so the response is 409 with `"not BE12599"` in the detail.
- `test_guarded_route_proceeds_for_the_named_series3_unit`: the unit answers `"BE9441"` with `serial="be9441 "` (normalised), and the write method is called once.
- `test_unguarded_stop_routes_send_without_an_identity_read`: `stop_monitoring_blind` (it writes through a bare `TcpTransport`; stub `srv.TcpTransport`) sends its stop frames, and nothing builds a client or reads a serial.
- [ ] **Step 2: Run them.** `…pytest tests/test_server_series3_guard.py -q` → FAIL (`_require_series3` / `read_serial` don't exist).
- [ ] **Step 3: Implement** `read_serial`, `_require_series3`, the `serial` query parameter, and the four guard calls as specified.
- [ ] **Step 4: Run** the new tests plus `tests/test_server_device_access.py` → PASS. Then the full suite → only the 16 known failures.
- [ ] **Step 5: Commit** `fix(sfm): legacy Series-3 writes and erase refuse a unit that does not answer as Series 3`.
### Task 2: Page — the device-routing block (pure functions) and its Node-run tests
**Files:**
- Modify: `sfm/sfm_webapp.html`. Add one `<script>` block, delimited by the lines `/* <device-routing> */` and `/* </device-routing> */`. It must not touch `document` or `fetch`.
- Test: create `tests/test_webapp_device_routing.py`. It extracts the block, appends `module.exports = {…}`, and runs cases through `node -e` (via `subprocess`, reading JSON on stdout). Skip with a clear reason if `shutil.which("node")` is `None`.
**Interfaces (Produces, used by Tasks 3–6):**
- `seriesFromSerial(serial) -> 3 | 4 | null`: trims and upper-cases; `UM…` → 4, `BE…`/`BA…` → 3 (prefix plus at least one more character), anything else → `null`. Mirrors `sfm/device_access/series.py`.
- `unitQuery(unit) -> string`, where `unit = {serial, host, tcpPort}`:
- serial mode: `serial=<NORMALISED>&host=<h>&tcp_port=<p>`;
- blank serial: `host=<h>&tcp_port=<p>`;
- every value goes through `encodeURIComponent`.
- `deviceUrl(action, unit, params = {}) -> {method, path}`: `path` is relative, e.g. `/device/info?serial=…`. Actions:
- `info`, `status`, `settings`, `events` → GET;
- `download` (needs `params.event_id`), `start`, `stop` → POST;
- `hangup` → POST, with no `serial` (host/port only);
- legacy actions: `storage_range`, `index`, `erase`, `rescue`, `blind_stop`, `slow_drip`, `call_home_read` (GET `/device/call_home`), `call_home_write`, `config_write` (POST `/device/config`).
`settings`, `download` and `hangup` with a blank serial return `null`, since there is no legacy equivalent. Unknown actions throw.
- `confirmedSeries(unit) -> 3 | 4 | null`, where `unit.confirmed = {serial, series}` comes from the last `/device/info` reply:
- returns `unit.confirmed.series` only when the normalised typed serial equals `unit.confirmed.serial`;
- with a blank typed serial, returns `unit.confirmed.series` from a legacy identify;
- otherwise `null`.
- `controlsFor(unit) -> {startStop, hangup, diagnostics, callHomeRead, configWrite, callHomeWrite, reasons}`, all booleans except `reasons`:
- `startStop` = serial mode and `confirmedSeries ∈ {3, 4}`;
- `hangup` = `confirmedSeries === 4`;
- `diagnostics` = `confirmedSeries === 3`;
- `callHomeRead` = `confirmedSeries === 3`;
- `configWrite` = `callHomeWrite` = `false`;
- `reasons` = `{configWrite: "Coming in phase 5 (#46)", callHomeWrite: "Coming in phase 4"}`.
- `changeSummary(body) -> string`, for a ChangeResult JSON (`action, outcome, verified, state_before, state_after, audit_id, plan`):
- `dry_run` → `"<action>: dry run — would send <subs comma-joined>"`;
- `skipped` → `"<action>: already <state_before> — nothing sent"`;
- `sent` + `ok` → `"<action>: confirmed — <state_before> → <state_after> (audit <id8>)"`;
- anything else → `"<action>: <outcome>, <verified> (audit <id8>)"`.
- `downloadSummary(body) -> string`, for an EventDownload JSON:
- `inserted: false` → `"already stored — <stored_filename>"`;
- otherwise `"stored <stored_filename>, <filesize> bytes, check: <detail.check>"`.
- [ ] **Step 1: Write the failing test file.** Each case is `(function, args, expected)` and runs as `node` evaluating `JSON.stringify(fn(...args))`. Cases that must be present:
- `seriesFromSerial`: `"UM20147"`→4, `" be9441 "`→3, `"BA123"`→3, `"BE"`→null, `"XX1"`→null.
- `unitQuery`: serial mode upper-cases and trims; blank serial omits `serial=`; a host with `&` is encoded.
- `deviceUrl`: `info` with a serial → `{method:"GET", path:"/device/info?serial=BE9441&host=h&tcp_port=9034"}`; `hangup` → no `serial`; `settings` with a blank serial → `null`; `download` carries `event_id`.
- controls (named for Review Focus 1 and 2):
- **typed serial is not confirmation**: typed `BE9441` with `confirmed:null` → `diagnostics:false, startStop:false`;
- **confirmed S3**: diagnostics true, hangup false;
- **confirmed S4**: hangup true, diagnostics false, callHomeRead false;
- **confirmation drops when the serial changes**: confirmed `{serial:"BE9441",series:3}` with typed `BE9442` → all false;
- config/call-home write always false, with the exact reason strings.
- `changeSummary`: one case per outcome, including `failed` with `verified:"not_checked"` and `sent` with `verified:"mismatch"`.
- `downloadSummary`: inserted and already-stored.
- [ ] **Step 2: Run** → FAIL (no block in the page).
- [ ] **Step 3: Implement** the block in the page, just before the existing main `<script>`'s first function. Exactly the functions above, no DOM.
- [ ] **Step 4: Run** → PASS. Full suite → only the 16 known failures.
- [ ] **Step 5: Commit** `feat(webapp): the device-routing rules as pure functions, tested through Node`.
### Task 3: Page — unit bar, series badge, Device tab and status panel, Hang up
**Files:** Modify `sfm/sfm_webapp.html`. Test: extend `tests/test_webapp_device_routing.py` with the static check below.
**Interfaces:**
- Consumes: `unitQuery`, `deviceUrl`, `confirmedSeries`, `controlsFor` (Task 2).
- Produces: a page-level `currentUnit()` returning `{serial, host, tcpPort, confirmed}`. `confirmed` is held in a module variable set only by `connectUnit()` from the `/device/info` reply (`{serial: body.serial, series: body.series}`), and cleared whenever the serial or host field changes. Also `applyControls()`, which sets every series-specific control's `disabled`/`hidden` state and tooltip from `controlsFor(currentUnit())`. Tasks 4–6 call `applyControls()` after any state change.
- [ ] **Step 1: Write the failing static test.** `test_every_device_url_is_built_by_deviceUrl`: outside the device-routing block, the page source contains no `` `${api()}/device/ `` and no `'/device/` string literal. The `deviceUrl` call sites are the only way to build one.
- [ ] **Step 2: Run** → FAIL (today's page builds them by hand).
- [ ] **Step 3: Implement.**
- A **Serial** input beside host/port, `id="dev-serial"`, with placeholder `"BE…/BA… or UM… (optional)"`.
- A badge `id="series-badge"` showing `Series 3` / `Series 4` from `confirmedSeries`, or hidden.
- `connectUnit()` and `refreshMonitorStatus()` go through `deviceUrl('info'|'status', …)`. The Device tab and status panel render `UnitInfo`/`UnitStatus` fields with "—" for null (`device_time` and `event_count` are null on Series 3).
- A **Hang up** button `id="hangup-btn"`, visible only when `controlsFor().hangup`, which POSTs `deviceUrl('hangup')`.
- Convert every remaining hand-built `/device/` URL to `deviceUrl` (legacy actions included), so the static test passes. With a blank serial, behaviour is unchanged.
- [ ] **Step 4: Run** the page tests and the full suite → PASS, only the 16 known failures.
- [ ] **Step 5: Commit** `feat(webapp): name a unit by serial; series badge from the unit's own answer; Hang up for Series 4`.
### Task 4: Page — Events tab by serial
**Files:** Modify `sfm/sfm_webapp.html`.
**Interfaces:**
- Consumes: `deviceUrl('events'|'download')`, `downloadSummary` (Task 2), `currentUnit()` (Task 3), and the existing `openSidecarModal(dbEventId)` (~line 2780).
- [ ] **Step 1: Implement.** In serial mode, the Events tab lists `EventList.events`: index, `timestamp`, `record_type`, PVS and peaks, or "—". Each row has a **Download** button that POSTs `deviceUrl('download', unit, {event_id})`, shows `downloadSummary(body)` in the status bar, and then calls `openSidecarModal(body.db_event_id)` when it isn't null. HTTP errors show `detail` verbatim. With a blank serial, the existing legacy list and waveform behaviour is unchanged.
- [ ] **Step 2: Verify** the page tests and the full suite → only the 16 known failures. The bench check covers the live behaviour.
- [ ] **Step 3: Commit** `feat(webapp): list and download events by serial, for both series`.
### Task 5: Page — Start/Stop through the audited path
**Files:** Modify `sfm/sfm_webapp.html`.
**Interfaces:**
- Consumes: `deviceUrl('start'|'stop')`, `changeSummary`, `controlsFor().startStop` (Task 2).
- [ ] **Step 1: Implement.**
- In serial mode, `startMonitoring()`/`stopMonitoring()` `confirm()` with `"Start monitoring on <serial>?"` / `"Stop monitoring on <serial>?"`.
- Then POST once (never retried). While a start is in flight, show "Starting — the unit runs its sensor check first (about 35 s)".
- Show `changeSummary(body)` for any JSON body, including a 409/502 ChangeResult; show `detail` verbatim for an error without one (e.g. 504).
- Then call `refreshMonitorStatus()`.
- Buttons are enabled only by `controlsFor().startStop`.
- In serial mode the legacy `_pollMonitorConfirm` isn't called. With a blank serial, the legacy behaviour is unchanged.
- [ ] **Step 2: Verify** the page tests and the full suite → only the 16 known failures. Task 2's `changeSummary` cases cover the 409/`mismatch` and `failed` bodies; the bench check covers the live behaviour.
- [ ] **Step 3: Commit** `feat(webapp): start/stop through the audited serial path, with the honest result`.
### Task 6: Page — Config, Call Home and Diagnostics gating
**Files:** Modify `sfm/sfm_webapp.html`.
**Interfaces:**
- Consumes: `deviceUrl('settings'|'call_home_read'|…)`, `controlsFor()` (Task 2), `applyControls()` (Task 3).
- [ ] **Step 1: Implement.**
- **Config tab:** in serial mode, **Read** shows `UnitSettings` (setup name, record mode, sample rate, record time, histogram interval, geo trigger, notes, with "—" for null). **Write** is disabled for both series, with the tooltip from `reasons.configWrite`.
- **Call Home tab:** read enabled only by `callHomeRead`; for Series 4 it says "Not yet available for Series 4". Write is disabled, with `reasons.callHomeWrite`.
- **Diagnostics:** every button is enabled only by `controlsFor().diagnostics`; the erase confirmation stays as is. Diagnostics requests pass `serial` when one is typed, so the server guard (Task 1) checks it as well.
- With a blank serial, the legacy reads are unchanged, while writes and erase follow `controlsFor`. A legacy identify (blank serial) that answers as BE… confirms Series 3.
- [ ] **Step 2: Verify** the page tests and the full suite → only the 16 known failures.
- [ ] **Step 3: Commit** `feat(webapp): config and call-home writes wait for phases 4-5; Diagnostics only for a confirmed Series-3 unit`.
### Task 7: Docs
**Files:** `CLAUDE.md` (the SFM REST API section, and "Where things stand"), `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` (the 1c entry in Build phases).
- [ ] **Step 1:** Document:
- the legacy-route Series-3 guard (which routes, why the stop tools are exempt);
- the page's serial mode;
- the `node` requirement for `tests/test_webapp_device_routing.py`.
No CHANGELOG (feature branch).
- [ ] **Step 2: Commit** `docs: phase 1c -- the webapp by serial, and the Series-3 guard on legacy writes`.
**After Task 7 (controller, with Brian, not an implementer task):** a bench pass on BE9441 and UM20147, through the bridge or cellular:
- identify;
- status;
- settings read;
- events list and one download each;
- one audited start/stop each (Brian's go per send);
- for the Micromate, Hang up;
- Diagnostics disabled on UM20147, and enabled only after BE9441 identifies.