Three things the first real call-in exposed. UM12947's modem dialled in at 14:16:56 from 63.45.161.30 -- the network path works -- and sent 60 bytes of "RADIO RING", space-padded and newline-separated, four times. 1. THAT IS MODEM CHATTER, NOT THE UNIT, and the server left it as a hex dump to interpret by hand. CLAUDE.md already records that an RV50/RV55 "sends \r\nRING\r\n\r\nCONNECT\r\n over TCP to the caller even with Quiet Mode enabled"; an RX55 on AirLink OS says RADIO RING instead. The server now recognises the known modem strings and says so. ⚠ The diagnostic value is in what was MISSING: four RINGs and NO CONNECT. RING means the modem is ringing the serial device, CONNECT means something answered. Rings without a connect, plus no answer to POLL, means TCP is fine and the unit is not on the other end of the serial link. The server now prints that conclusion and the three things to check -- cabled at all, cable chipset (FTDI/CDC-ACM only, never Prolific), and a cold boot with the cable attached, since the USB-A host port only enumerates at power-on. 2. STDOUT WAS BLOCK-BUFFERED. With output redirected, every print sat in a buffer, so the log read EMPTY while a call was in progress and the session was only discoverable on disk afterwards. For a tool whose whole job is to be watched during a one-shot event, that is close to useless. Line-buffered now. 3. THE DOCSTRING PROMISED SCANNERS LEAVE NO TRACE ON DISK, AND THEY DID. The failed-handshake path created a session directory unconditionally -- my own loopback sanity check produced one. Now a connection that sends nothing AND fails the handshake is discarded with no directory; one that sent something unprompted is always kept, because that is the interesting case. Also recorded in session.json: modem_chatter, ring_count and a diagnosis string, so a session can be triaged without re-reading the raw bytes. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
377 lines
17 KiB
Python
377 lines
17 KiB
Python
#!/usr/bin/env python3
|
|
"""
|
|
mm_ach_server.py — inbound Auto Call Home server for Micromate (Series IV).
|
|
|
|
**Read-only.** It identifies the unit, reads its state and setups, and walks the
|
|
event chain. It does not erase, does not write, does not start or stop
|
|
monitoring, and downloads nothing unless asked. Series III's `ach_server.py`
|
|
has "rescue actions" that quiet a runaway unit; those are deliberately absent
|
|
here, because no command has ever been originated against a unit by this project
|
|
and an inbound session is the worst place to break that.
|
|
|
|
What this is for
|
|
----------------
|
|
The inbound call-home session is the last unmapped part of the Series IV
|
|
protocol.
|
|
|
|
⚠ **No Micromate has ever been observed calling home.** The 72 `ach_inbound_*`
|
|
sessions in `bridges/captures/` are **MiniMate Plus**, and the Series III setup
|
|
does not automatically transfer. What we have for Series IV is prior, not
|
|
observation:
|
|
|
|
* The THOR manual §6.2 and the firmware's own strings
|
|
(`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING`, `Call Home Deleting
|
|
Events`) say the unit dials in and then **waits to be told what to do** —
|
|
server-driven, the same shape as Series III's pull model.
|
|
* UM12947's `0x2C` dial string reads literally `"RADIO RING"`, which is modem
|
|
*answer* vocabulary rather than a destination. With the RV50 debug string
|
|
`ATQ1 ATE0 ATS0=2 … RADIO RING` — `ATS0=2` being auto-answer-after-2-rings —
|
|
that reads as the unit configuring the modem to **accept** calls, i.e. the
|
|
call-*up* path. Which suggests the ACH destination lives in the **modem**,
|
|
as it does for Series III.
|
|
|
|
**If both priors hold, this file is just `MicromateClient` on an inbound socket
|
|
and the unknown evaporates.** But there is a specific way it can fail:
|
|
|
|
⚠ **Those AT strings prove the Micromate talks to the modem over serial.** If it
|
|
drives an AT dial for call-home, that exchange happens on the **serial link**,
|
|
where a TCP listener sees nothing whatsoever. So a null result here is
|
|
informative but ambiguous — it means *either* the trigger did not fire *or* the
|
|
interesting part is happening somewhere this tool cannot watch. **If nothing
|
|
arrives, the next step is a serial-level capture between the unit and the modem,
|
|
not more fiddling with this server.**
|
|
|
|
**The one question that matters is push vs pull**, and it cannot be answered by
|
|
sniffing — only by connecting and keeping quiet. So this server **says nothing
|
|
for `--grace` seconds** after accepting. If bytes arrive in that window the unit
|
|
speaks first (push) and the server reports exactly what it sent. If the window
|
|
passes in silence, it is pull, and the normal handshake follows.
|
|
|
|
Setup
|
|
-----
|
|
1. Run this where the unit can reach it:
|
|
|
|
python3 bridges/mm_ach_server.py --port 12345
|
|
|
|
2. Point the call-home destination at this machine. **For Series III that
|
|
lived in the MODEM's config (ACEmanager), not in the seismograph** — so try
|
|
AirLink OS first. If the RX55 can be told to open an outbound TCP session
|
|
to `<your IP>:12345` on serial activity, nothing on the instrument needs to
|
|
change, which is much the better outcome.
|
|
|
|
If it has to come from the unit instead, its `SUB 0x2C` call-home block
|
|
holds a 40-byte dial string — but **writing that is THOR's job, not ours.**
|
|
|
|
3. Trigger a call. A scheduled time is the controllable option: repeatable,
|
|
needs no monitoring and no thumping. An event-triggered call is the more
|
|
interesting session, because it shows how an event gets offered.
|
|
|
|
4. Watch. Every frame is decoded as it arrives.
|
|
|
|
⚠ Use a bench unit. Changing a call-home destination means a unit stops
|
|
reporting to THOR until it is changed back.
|
|
|
|
Output per session, in the layout `scratch/mm_frame_parse.py` reads directly:
|
|
|
|
bridges/captures/mm_ach_<ts>/
|
|
raw_bw_<ts>.bin us → unit
|
|
raw_s3_<ts>.bin unit → us
|
|
session_<ts>.log
|
|
session.json what we learned, including push-vs-pull
|
|
"""
|
|
|
|
from __future__ import annotations
|
|
|
|
import argparse
|
|
import datetime
|
|
import json
|
|
import logging
|
|
import socket
|
|
import sys
|
|
import threading
|
|
import time
|
|
from pathlib import Path
|
|
|
|
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
|
|
|
|
from micromate.client import MicromateClient # noqa: E402
|
|
from micromate.framing import MicromateFrameParser # noqa: E402
|
|
from micromate.protocol import ProtocolError # noqa: E402
|
|
from minimateplus.transport import SocketTransport # noqa: E402
|
|
|
|
log = logging.getLogger("mm_ach")
|
|
|
|
DEPTHS = ("identify", "state", "events", "download")
|
|
|
|
# Strings the MODEM puts on the wire, which are not the unit talking.
|
|
#
|
|
# `CLAUDE.md` already records that an RV50/RV55 "sends \r\nRING\r\n\r\nCONNECT\r\n
|
|
# over TCP to the caller even with Quiet Mode enabled". An RX55 on AirLink OS
|
|
# says `RADIO RING` instead, space-padded and newline-separated. Observed
|
|
# 2026-10-14 from UM12947's modem: four of them and **no CONNECT**.
|
|
#
|
|
# ⚠ The absence of CONNECT is the useful part. RING means the modem is ringing
|
|
# the serial device; CONNECT means something answered. Rings without a CONNECT,
|
|
# and no answer to POLL, means the TCP side is fine and the UNIT is not on the
|
|
# other end of the serial link.
|
|
_MODEM_CHATTER = (b"RADIO RING", b"RING", b"CONNECT", b"NO CARRIER", b"BUSY",
|
|
b"NO ANSWER", b"ERROR", b"OK")
|
|
|
|
|
|
class Session:
|
|
"""One inbound call. Captures every byte; decides push vs pull first."""
|
|
|
|
def __init__(self, sock: socket.socket, peer: str, args) -> None:
|
|
self.sock, self.peer, self.args = sock, peer, args
|
|
self.ts = datetime.datetime.now().strftime("%Y%m%d_%H%M%S")
|
|
self.found: dict = {"peer": peer, "started": self.ts}
|
|
self._rx: list[bytes] = []
|
|
self._tx: list[bytes] = []
|
|
self._rx_fh = self._tx_fh = None
|
|
|
|
# ── byte taps ─────────────────────────────────────────────────────────────
|
|
|
|
def _tap(self, transport) -> None:
|
|
"""Mirror every byte, buffered until we know this is a real unit."""
|
|
orig_read, orig_write = transport.read, transport.write
|
|
|
|
def read(n: int) -> bytes:
|
|
data = orig_read(n)
|
|
if data:
|
|
(self._rx_fh.write(data), self._rx_fh.flush()) if self._rx_fh \
|
|
else self._rx.append(data)
|
|
return data
|
|
|
|
def write(data: bytes) -> None:
|
|
orig_write(data)
|
|
if data:
|
|
(self._tx_fh.write(data), self._tx_fh.flush()) if self._tx_fh \
|
|
else self._tx.append(data)
|
|
|
|
transport.read, transport.write = read, write
|
|
|
|
def _open_capture(self) -> Path:
|
|
"""Create the session directory — only once we trust the peer.
|
|
|
|
A port scanner should leave nothing on disk.
|
|
"""
|
|
d = Path(self.args.output) / f"mm_ach_{self.ts}"
|
|
d.mkdir(parents=True, exist_ok=True)
|
|
# Named raw_bw/raw_s3 so scratch/mm_frame_parse.py reads the pair as-is.
|
|
self._tx_fh = open(d / f"raw_bw_{self.ts}.bin", "wb")
|
|
self._rx_fh = open(d / f"raw_s3_{self.ts}.bin", "wb")
|
|
for c in self._tx:
|
|
self._tx_fh.write(c)
|
|
for c in self._rx:
|
|
self._rx_fh.write(c)
|
|
self._tx_fh.flush()
|
|
self._rx_fh.flush()
|
|
self._tx.clear()
|
|
self._rx.clear()
|
|
return d
|
|
|
|
# ── the experiment ────────────────────────────────────────────────────────
|
|
|
|
def _listen_first(self, transport) -> bytes:
|
|
"""Say nothing for `--grace` seconds. Does the unit speak first?
|
|
|
|
This is the whole reason the server exists. A packet capture cannot
|
|
answer it: you have to connect, keep quiet, and see.
|
|
"""
|
|
print(f" listening in silence for {self.args.grace:.1f} s "
|
|
f"(push-vs-pull test)...")
|
|
deadline = time.monotonic() + self.args.grace
|
|
got = bytearray()
|
|
while time.monotonic() < deadline:
|
|
chunk = transport.read(4096)
|
|
if chunk:
|
|
got += chunk
|
|
else:
|
|
time.sleep(0.02)
|
|
return bytes(got)
|
|
|
|
def run(self) -> None:
|
|
print(f"\n=== inbound from {self.peer} at {self.ts} ===")
|
|
transport = SocketTransport(self.sock, peer=self.peer)
|
|
self._tap(transport)
|
|
|
|
unsolicited = self._listen_first(transport)
|
|
self.found["push"] = bool(unsolicited)
|
|
self.found["unsolicited_bytes"] = len(unsolicited)
|
|
|
|
if unsolicited:
|
|
print(f" ** PUSH ** — the unit sent {len(unsolicited)} B unprompted")
|
|
print(f" hex : {unsolicited[:64].hex(' ')}")
|
|
txt = "".join(chr(c) if 32 <= c < 127 else "." for c in unsolicited[:64])
|
|
print(f" ascii : |{txt}|")
|
|
hits = [c.decode() for c in _MODEM_CHATTER if c in unsolicited]
|
|
if hits:
|
|
rings = unsolicited.count(b"RING")
|
|
print(f" *** MODEM CHATTER, not the unit: {hits} ***")
|
|
self.found["modem_chatter"] = hits
|
|
self.found["ring_count"] = rings
|
|
if rings and b"CONNECT" not in unsolicited:
|
|
print(f" *** {rings} RING(s) and NO CONNECT. ***")
|
|
print(" The modem is ringing the serial device and nothing")
|
|
print(" is answering. TCP is fine; the UNIT is not on the")
|
|
print(" other end of the serial link. Check, in order:")
|
|
print(" 1. is the unit cabled to the modem at all?")
|
|
print(" 2. cable chipset -- FTDI (0403) or CDC-ACM only,")
|
|
print(" never Prolific (067b)")
|
|
print(" 3. cold-boot the unit WITH the cable attached;")
|
|
print(" its USB-A host port only enumerates at power-on")
|
|
self.found["diagnosis"] = "rings without connect: unit not on serial"
|
|
|
|
frames = MicromateFrameParser().feed(unsolicited)
|
|
if frames:
|
|
for f in frames:
|
|
print(f" frame : SUB=0x{f.sub:02x} "
|
|
f"(answers 0x{f.request_sub:02x}) {len(f.data)} B data, "
|
|
f"flags=0x{f.flags:02x}, chk "
|
|
f"{'ok' if f.checksum_valid else 'BAD'}")
|
|
self.found["unsolicited_subs"] = [f"0x{f.sub:02x}" for f in frames]
|
|
else:
|
|
print(" frame : none parsed — not a response frame. Could be")
|
|
print(" a banner (series III sends 'Operating System'")
|
|
print(" on cold boot) or a greeting we have not seen.")
|
|
else:
|
|
print(" ** PULL ** — silence. The unit is waiting to be driven,")
|
|
print(" same as series III. Running the normal handshake.")
|
|
|
|
# From here on it is the ordinary client, which is the point.
|
|
mm = MicromateClient(transport, recv_timeout=self.args.timeout)
|
|
try:
|
|
info = mm.connect()
|
|
except ProtocolError as e:
|
|
print(f" handshake FAILED: {type(e).__name__}: {e}")
|
|
if not unsolicited:
|
|
print(" Nothing unprompted AND no answer to POLL — so this is")
|
|
print(" neither push nor pull as we understand it. The raw")
|
|
print(" capture is the thing to look at; keep it.")
|
|
self._finish(self._open_capture())
|
|
return
|
|
|
|
d = self._open_capture()
|
|
print(f" {info}")
|
|
self.found["device"] = {
|
|
"serial": info.serial, "model": info.model,
|
|
"firmware_line": info.firmware_line, "monitoring": info.monitoring,
|
|
"active_setup": info.active_setup,
|
|
}
|
|
|
|
try:
|
|
if DEPTHS.index(self.args.depth) >= DEPTHS.index("state"):
|
|
st = mm.get_state()
|
|
print(f" {st}")
|
|
self.found["state"] = {
|
|
"monitoring": st.monitoring,
|
|
"device_time": st.device_time.isoformat() if st.device_time else None,
|
|
"battery_volts": st.battery_volts,
|
|
"memory_free_bytes": st.memory_free_bytes,
|
|
}
|
|
self.found["setups"] = mm.list_setups()
|
|
print(f" {len(self.found['setups'])} setups")
|
|
|
|
if DEPTHS.index(self.args.depth) >= DEPTHS.index("events"):
|
|
refs = mm.list_events()
|
|
print(f" {len(refs)} events")
|
|
self.found["events"] = []
|
|
for r in refs:
|
|
print(f" {r}")
|
|
self.found["events"].append({
|
|
"uid": r.uid, "key": r.key_hex, "size": r.size,
|
|
"type": r.record_type, "filename": r.filename,
|
|
"timestamp": r.timestamp.isoformat() if r.timestamp else None,
|
|
"pvs_ips": r.peak_vector_sum_ips,
|
|
})
|
|
|
|
if self.args.depth == "download":
|
|
# Bounded on purpose: an unknown session is a poor place to
|
|
# discover that a 70 KB pull takes 30 s and the unit hung up.
|
|
for r in refs[: self.args.max_events]:
|
|
blob = mm.download_event(r)
|
|
out = d / (r.filename or f"{r.key_hex}.bin")
|
|
out.write_bytes(blob)
|
|
print(f" saved {out.name} ({len(blob)} B)")
|
|
except ProtocolError as e:
|
|
print(f" session ended early: {type(e).__name__}: {e}")
|
|
self.found["error"] = f"{type(e).__name__}: {e}"
|
|
|
|
self._finish(d)
|
|
|
|
def _finish(self, d: Path) -> None:
|
|
for fh in (self._rx_fh, self._tx_fh):
|
|
if fh:
|
|
fh.close()
|
|
(d / "session.json").write_text(json.dumps(self.found, indent=2))
|
|
try:
|
|
self.sock.close()
|
|
except OSError:
|
|
pass
|
|
print(f" saved {d}")
|
|
print(f" parse with: python3 scratch/mm_frame_parse.py {d}")
|
|
|
|
|
|
def main() -> int:
|
|
ap = argparse.ArgumentParser(
|
|
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
|
|
)
|
|
ap.add_argument("--port", type=int, default=12345)
|
|
ap.add_argument("--bind", default="0.0.0.0")
|
|
ap.add_argument("--output", default="bridges/captures")
|
|
ap.add_argument("--timeout", type=float, default=30.0,
|
|
help="per-command receive timeout; generous, because an "
|
|
"inbound cellular session is the slow case")
|
|
ap.add_argument("--grace", type=float, default=5.0,
|
|
help="seconds to stay SILENT after accepting, to see whether "
|
|
"the unit speaks first. This is the experiment; do not "
|
|
"set it to 0 on a first run.")
|
|
ap.add_argument("--depth", choices=DEPTHS, default="events",
|
|
help="how far to take the session. 'events' walks the chain "
|
|
"without downloading (default); 'download' also fetches "
|
|
"events, which on cellular is ~0.21 s + bytes/2350 each")
|
|
ap.add_argument("--max-events", type=int, default=3,
|
|
help="with --depth download, how many to fetch")
|
|
ap.add_argument("--once", action="store_true",
|
|
help="exit after the first session instead of listening on")
|
|
a = ap.parse_args()
|
|
|
|
# ⚠ Without this, stdout is block-buffered whenever it is not a terminal,
|
|
# so the live session commentary sits in a buffer and the log looks EMPTY
|
|
# while a call is happening. That cost a confusing few minutes on the first
|
|
# real call-in: the session was on disk but nothing was on screen.
|
|
try:
|
|
sys.stdout.reconfigure(line_buffering=True)
|
|
except AttributeError: # pragma: no cover - py<3.7
|
|
pass
|
|
|
|
logging.basicConfig(level=logging.INFO,
|
|
format="%(asctime)s %(levelname)-7s %(message)s")
|
|
|
|
srv = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
|
|
srv.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
|
|
srv.bind((a.bind, a.port))
|
|
srv.listen(5)
|
|
print(f"\nMicromate ACH server on {a.bind}:{a.port} (READ-ONLY)")
|
|
print(f" depth={a.depth} grace={a.grace}s timeout={a.timeout}s")
|
|
print(" waiting for a unit to call in. Ctrl-C to stop.\n")
|
|
|
|
try:
|
|
while True:
|
|
sock, addr = srv.accept()
|
|
peer = f"{addr[0]}:{addr[1]}"
|
|
s = Session(sock, peer, a)
|
|
if a.once:
|
|
s.run()
|
|
return 0
|
|
threading.Thread(target=s.run, daemon=False).start()
|
|
except KeyboardInterrupt:
|
|
print("\nstopped")
|
|
return 0
|
|
finally:
|
|
srv.close()
|
|
|
|
|
|
if __name__ == "__main__":
|
|
raise SystemExit(main())
|