serversdown 8c17af4849 fix: ignore garbled measurement-state reads (phantom STOPPED/STARTED)
A buffer desync on the shared persistent connection (commonly right after
a DRD/DOD test) can make a Measure? read return a stray value. The state
classifier treated anything not in {"Start","Measure"} as "not measuring",
so a garbled read logged a phantom STOPPED, the next clean read logged
STARTED, and that reset measurement_start_time — producing constant
STOPPED/STARTED device-log pairs and a drifting elapsed timer.

Now only recognized states drive transitions: {"Start","Measure"} =
measuring, {"Stop"} = stopped, anything else = no change. Garbled reads
are also not persisted as the cached state, so they can't poison the next
transition check. Builds on the earlier Start<->Measure normalization.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-08 22:50:18 +00:00
serversdown b954eb8c89 feat: per-unit deactivate and global SLMM standby
Lets an instance stop occupying a device's single TCP connection slot so
another instance (e.g. prod) can take over.

Per-unit:
- POST /api/nl43/{unit_id}/deactivate — poll_enabled=False (persisted) +
  drop the connection (waits up to 10s for in-flight ops via the device
  lock, then discards). Unit stays dormant across restarts.
- POST /api/nl43/{unit_id}/activate — re-enable polling.

Global standby:
- POST /api/nl43/_system/standby — poller idles and releases ALL
  connections; the loop keeps re-releasing so the instance holds no slots.
- POST /api/nl43/_system/resume — resume polling.
- GET  /api/nl43/_system/status — active vs standby + active_connections.
- SLMM_POLLING_ENABLED=false starts an instance in standby (persistent
  way to keep a dev box from latching onto a prod-owned device).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-08 22:45:52 +00:00
serversdown 0793e7df01 feat: add per-device disconnect endpoint
POST /api/nl43/{unit_id}/disconnect cleanly closes (TCP FIN + wait_closed)
and drops the pooled connection for a single device, freeing the NL43's
one connection slot. Previously only /_connections/flush existed, which
tears down every device at once.

Idempotent; no-op if nothing is cached. Releases the idle pooled
connection only — an active DRD stream/command has the socket checked out
of the pool, so close the stream WebSocket to end a live stream.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-08 22:40:56 +00:00
serversdown 51dd6b682d feat: surface LN1/LN2 (L1/L10) percentiles through SLMM
Completes the SLMM side of the L1/L10 live-display contract. The NL-43's
DOD response carries percentile slots LN1-LN5 (channel 1, parts[5]/[6]);
parse the first two and expose them as ln1/ln2 end to end:

- NL43Snapshot dataclass: ln1/ln2 fields
- NL43Status model: ln1/ln2 columns (+ migrate_add_ln_percentiles.py)
- DOD parser: snap.ln1=parts[5], snap.ln2=parts[6]
- persist_snapshot writes them
- all /status data dicts, StatusPayload, and the DRD stream payload emit
  ln1/ln2 (null on the DRD stream itself, which doesn't carry percentiles)

Labels: device LN1 defaults to L5, not L1 — Terra-View defaults the label
to L1/L10, so the device's Ln1/Ln2 slots must be set to 1%/10% for the
labels to be accurate (dynamic label emission is a follow-up).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-08 22:01:31 +00:00
serversdown a7983d2958 fix: correct DOD field parsing and stop measurement-time resets
Two device-data bugs surfaced while scoping the live-feed work:

1. DOD parser misalignment. DOD's response has no leading counter and
   includes LE + LN1-LN5, but the parser reused the DRD field map
   (parts[0]=counter). That shifted everything: Lp was stored as the
   counter, Leq as Lp, LE as Leq, and LN1 as Lpeak (visible because
   "Lpeak" came out below Lmax, which is impossible). Parse DOD with its
   own map: Lp=0, Leq=1, Lmax=3, Lmin=4, Lpeak=10 (channel 1 = main).

2. measurement_start_time reset on every live-stream open/close. The DOD
   path tags state "Start"; the DRD stream path tags "Measure". The
   transition detector treated only "Start" as measuring, so opening the
   stream ("Start"->"Measure") read as a stop (cleared start time) and
   closing it ("Measure"->"Start") read as a start (reset to now). Every
   viewer reset the elapsed measurement time. Treat {"Start","Measure"}
   both as measuring.

LN1/LN2 (L1/L10) parsing + model/serialization is the next step.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-08 21:53:00 +00:00
serversdown d6dd2e736b Merge pull request 'fix: improve connection pool idle and max age checks to allow disabling' (#3) from dev-persistent into main
Reviewed-on: #3
2026-06-08 16:56:33 -04:00
serversdown ad1a40e0aa Merge pull request 'v0.3.0, persistent polling update. Persistent TCP connection pool with all features Connection pool diagnostics (API + UI) All 6 new environment variables Changes to health check, diagnostics, and DRD streaming Technical architecture details and cellular' (#2) from dev-persistent into main
Reviewed-on: #2
2026-02-16 21:57:37 -05:00