SLM Configuration Interface

This document describes the SLM configuration interface added to the Sound Level Meters dashboard.

Overview

Sound Level Meters can now be configured directly from the dashboard without needing to navigate to the unit detail page. A configuration button appears on each SLM unit card on hover, opening a modal with all configurable parameters.

Features

1. Quick Access Configuration Button

  • Location: Appears on each SLM unit card in the unit list
  • Behavior: Shows on hover (desktop) or always visible (mobile)
  • Icon: Gear/settings icon in top-right corner of unit card

2. Configuration Modal

The configuration modal provides a comprehensive interface for all SLM parameters:

Device Information

  • Model: Dropdown selection (NL-43, NL-53)
  • Serial Number: Text input for device serial number

Measurement Parameters

  • Frequency Weighting: A, C, or Z (Linear)
  • Time Weighting: Fast (125ms), Slow (1s), or Impulse
  • Measurement Range: 30-130 dB, 40-140 dB, or 50-140 dB

Network Configuration

  • Assigned Modem: Dropdown list of available modems
    • Shows modem ID and IP address
    • Option for "No modem (direct connection)"
  • Direct IP Address: Only shown when no modem assigned
  • TCP Port: Only shown when no modem assigned (default: 502)

3. Actions

The modal provides three action buttons:

  • Test Connection: Tests network connectivity to the SLM

    • Uses current form values (not saved values)
    • Shows toast notification with results
    • Green: Connection successful
    • Yellow: Connection failed or device offline
    • Red: Test error
  • Cancel: Closes modal without saving changes

  • Save Configuration: Saves all changes to database

    • Shows success/error toast
    • Refreshes unit list on success
    • Auto-closes modal after 2 seconds

Implementation

Frontend Components

Unit List Partial

File: templates/partials/slm_unit_list.html

<!-- Configure button (appears on hover) -->
<button onclick="event.stopPropagation(); openConfigModal('{{ unit.id }}');"
        class="absolute top-2 right-2 opacity-0 group-hover:opacity-100...">
    <svg>...</svg>
</button>

Configuration Modal

File: templates/sound_level_meters.html

<!-- Configuration Modal -->
<div id="config-modal" class="hidden fixed inset-0 bg-black bg-opacity-50...">
    <div id="config-modal-content">
        <!-- Content loaded via HTMX -->
    </div>
</div>

Configuration Form

File: templates/partials/slm_config_form.html

Form fields mapped to database columns:

  • slm_modelunit.slm_model
  • slm_serial_numberunit.slm_serial_number
  • slm_frequency_weightingunit.slm_frequency_weighting
  • slm_time_weightingunit.slm_time_weighting
  • slm_measurement_rangeunit.slm_measurement_range
  • deployed_with_modem_idunit.deployed_with_modem_id
  • slm_hostunit.slm_host (legacy, only if no modem)
  • slm_tcp_portunit.slm_tcp_port (legacy, only if no modem)

Backend Endpoints

GET /api/slm-dashboard/config/{unit_id}

File: backend/routers/slm_dashboard.py:184

Returns configuration form HTML partial with current unit values pre-populated.

Response: HTML partial (slm_config_form.html)

POST /api/slm-dashboard/config/{unit_id}

File: backend/routers/slm_dashboard.py:203

Saves configuration changes to database.

Request: Form data with configuration parameters

Response: JSON

{
  "status": "success",
  "unit_id": "nl43-001"
}

Behavior:

  • Updates all SLM-specific fields from form data
  • If modem is assigned: clears legacy slm_host and slm_tcp_port
  • If no modem: uses direct IP fields from form

JavaScript Functions

openConfigModal(unitId)

File: templates/sound_level_meters.html:127

Opens configuration modal and loads form via HTMX.

function openConfigModal(unitId) {
    const modal = document.getElementById('config-modal');
    modal.classList.remove('hidden');

    htmx.ajax('GET', `/api/slm-dashboard/config/${unitId}`, {
        target: '#config-modal-content',
        swap: 'innerHTML'
    });
}

closeConfigModal()

File: templates/sound_level_meters.html:136

Closes configuration modal.

handleConfigSave(event)

File: templates/partials/slm_config_form.html:109

Handles HTMX response after form submission:

  • Shows success/error toast
  • Refreshes unit list
  • Auto-closes modal after 2 seconds

testConnection(unitId)

File: templates/partials/slm_config_form.html:129

Tests connection to SLM unit:

async function testConnection(unitId) {
    const response = await fetch(`/api/slmm/${unitId}/status`);
    const data = await response.json();

    if (response.ok && data.status === 'online') {
        // Show success toast
    } else {
        // Show warning toast
    }
}

loadModemsForConfig()

File: templates/partials/slm_config_form.html:87

Loads available modems from /api/roster/modems and populates dropdown.

User Workflow

Configuring an SLM

  1. Navigate to Sound Level Meters dashboard (/sound-level-meters)
  2. Hover over desired SLM unit card in the list
  3. Click the gear icon that appears in top-right corner
  4. Configuration modal opens with current values pre-filled
  5. Modify desired parameters:
    • Update model/serial if needed
    • Set measurement parameters (frequency/time weighting, range)
    • Choose network configuration:
      • Option A: Select a modem from dropdown (recommended)
      • Option B: Enter direct IP address and port
  6. (Optional) Click "Test Connection" to verify network settings
  7. Click "Save Configuration"
  8. Modal shows success message and auto-closes
  9. Unit list refreshes to show updated information

Network Configuration Options

Modem Assignment (Recommended):

  • Select modem from dropdown
  • IP address automatically resolved from modem's ip_address field
  • Direct IP/port fields hidden
  • Enables modem tracking and management

Direct Connection (Legacy):

  • Select "No modem (direct connection)"
  • Enter IP address and TCP port manually
  • Direct IP/port fields become visible
  • Useful for temporary setups or non-modem connections

Database Schema

The configuration interface updates these roster table columns:

-- SLM-specific fields
slm_model VARCHAR               -- Device model (NL-43, NL-53)
slm_serial_number VARCHAR       -- Serial number
slm_frequency_weighting VARCHAR -- A, C, or Z weighting
slm_time_weighting VARCHAR      -- Fast, Slow, or Impulse
slm_measurement_range VARCHAR   -- Measurement range (30-130, 40-140, 50-140)

-- Network configuration
deployed_with_modem_id VARCHAR  -- FK to modem unit (preferred method)
slm_host VARCHAR                -- Legacy direct IP (only if no modem)
slm_tcp_port INTEGER            -- Legacy TCP port (only if no modem)

UI/UX Design

Modal Behavior

  • Opens: Via configure button on unit card
  • Closes:
    • Cancel button
    • X button in header
    • Escape key
    • Clicking outside modal (on backdrop)
  • Auto-close: After successful save (2 second delay)

Responsive Design

  • Desktop: Configuration button appears on hover
  • Mobile: Configuration button always visible
  • Modal: Responsive width, scrollable on small screens
  • Form: Two-column layout on desktop, single column on mobile

Visual Feedback

  • Loading: Skeleton loader while form loads
  • Saving: HTMX handles form submission
  • Success: Green toast notification
  • Error: Red toast notification
  • Testing: Blue toast while testing, then green/yellow/red based on result

Accessibility

  • Keyboard: Modal can be closed with Escape key
  • Focus: Modal traps focus when open
  • Labels: All form fields have proper labels
  • Colors: Sufficient contrast in dark/light modes

Future Enhancements

Potential improvements for future versions:

  1. Bulk Configuration: Configure multiple SLMs at once
  2. Configuration Templates: Save and apply configuration presets
  3. Configuration History: Track configuration changes over time
  4. Remote Configuration: Push configuration directly to device via SLMM
  5. Validation: Real-time validation of IP addresses and ports
  6. Advanced Settings: Additional NL-43/NL-53 specific parameters
  7. Configuration Import/Export: JSON/CSV configuration files