docs: phase 1c -- the webapp by serial, and the Series-3 guard on legacy writes
- CLAUDE.md: a 1c entry under Where things stand (serial mode, what follows the unit's own answer, writes off until phases 4-5, the Node-run page tests) and the legacy-route guard in the REST API notes, with why the stop tools are exempt. - Spec: the 1c build status; the ring-path Runs A/B are still owed before serial mode is used on a unit that calls home to THOR; which parked 1c items the page settles (CORS: same origin; the S4 mic is not shown). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
c4cb979dfb
commit
073284fc88
2 files changed
+60
-1
No files matched your search
@@ -164,7 +164,37 @@ Read this first when picking the project back up.
|
||||
start's read-back waited out the ~30 s sensor check and re-sent the wake
|
||||
(`9886422`, `ca5c401`; a monitoring MiniMate answers nothing until woken, and
|
||||
nothing during its sensor check). Still owed before merge: #47 from dev, and
|
||||
`persist_download` aligned with dev's waveform-time restamp (spec). Next: 1c.
|
||||
`persist_download` aligned with dev's waveform-time restamp (spec).
|
||||
- **Phase 1c: the SFM webapp by serial (2026-10-29), built; bench pass owed.**
|
||||
`sfm/sfm_webapp.html` has a **Serial** field beside host/port. With one, the
|
||||
Live tabs use the serial-based routes for both series: identify, status (now
|
||||
with the unit's clock and event count), settings (read-only), the event list
|
||||
with a Download per row (checked, stored, then opened from the store), and
|
||||
audited start/stop (asks first, one send, shows the ChangeResult as it is).
|
||||
Hang up appears for a Series 4. Every series-specific control follows the
|
||||
unit's own `/device/info` answer, never the typed serial, and drops the
|
||||
moment the serial, host or port is edited. Config and call-home **writes are
|
||||
off for both series** (phases 5 and 4); Diagnostics is enabled only for a
|
||||
confirmed Series 3. Without a serial every read behaves as before.
|
||||
The page keeps every routing and button rule in one block of pure functions
|
||||
between `/* <device-routing> */` markers, run through **Node** by
|
||||
`tests/test_webapp_device_routing.py` (skipped when `node` is absent); a
|
||||
static test fails if a `/device/` URL is built anywhere else.
|
||||
**Server side:** the legacy Series-3 writes and erase -- `POST /device/config`
|
||||
(and `/config/project`), `/events/erase`, `/rescue` (when it disables ACH or
|
||||
erases), `POST /device/call_home` -- read the unit's serial (or reuse the one
|
||||
`connect()` read) and refuse 409, nothing sent, unless it is Series 3 and,
|
||||
when `serial=` was given, that unit. 0xA2 is CONFIRM ERASE on a MiniMate and
|
||||
ends a call-home on a Micromate. The stop tools (legacy `monitor/start|stop`,
|
||||
`stop_monitoring_blind`, `_slow_drip`, `_spam`) are exempt: 0x96/0x97 mean
|
||||
the same on both series, and the blind tools must reach a unit too wedged to
|
||||
answer.
|
||||
⚠ **Before serial mode is used on a unit that calls home to THOR, run the
|
||||
ring-path Runs A/B** (spec, *Open questions ... for the bench*): a held line
|
||||
holds the modem's single TCP session. The page never polls (every request is
|
||||
a click), SFM hangs up on RADIO RING, and **Hang up** releases the line at
|
||||
once; whether a call-home still reaches THOR is unmeasured.
|
||||
Next: the bench pass on BE9441 and UM20147, then phases 4 and 5.
|
||||
- **✅ Phase 3: start / stop monitoring by serial (2026-10-23) — built,
|
||||
reviewed, and bench-verified on UM20147 (2026-10-25).** Start acked in
|
||||
0.46 s and read back as monitoring at the first 2 s poll (during the sensor
|
||||
@@ -1582,6 +1612,11 @@ POST /device/hangup?host=1.2.3.4&tcp_port=9034 ← release a held Serie
|
||||
nothing; `even_if_already=true` sends even when the unit is already in that state). A
|
||||
`UM` serial on any other `/device/*` route is 501; any request taking the legacy
|
||||
Series-3 path at a held Series-4 address is 409.
|
||||
The legacy Series-3 writes and erase (`POST /device/config`, `/config/project`,
|
||||
`/events/erase`, `/rescue`, `POST /device/call_home`) take an optional `serial=` and
|
||||
refuse 409, nothing sent, when the unit at the address does not answer as Series 3
|
||||
or is not the named unit. The stop tools (`monitor/start|stop` without a serial,
|
||||
`stop_monitoring_blind`, `_slow_drip`, `_spam`) are exempt by design.
|
||||
SFM must run a single uvicorn worker (locks and held lines are per process).
|
||||
|
||||
Server retries once on `ProtocolError` for TCP connections (handles cold-boot timing).
|
||||
|
||||
@@ -490,6 +490,30 @@ Each safety piece arrives with its first real use, so nothing sits untested.
|
||||
address answer 503 + `Retry-After` until it expires, and
|
||||
`POST /device/hangup` clears it, with its length taken from Run A. If
|
||||
THOR gets the call anyway, no cool-down is needed.
|
||||
- **Built 2026-10-29** (plan `docs/superpowers/plans/2026-10-28-sfm-phase1c-webapp.md`).
|
||||
A Serial field beside host/port; with one, identify, status, settings
|
||||
(read-only), events (a Download per row) and audited start/stop go
|
||||
through the serial routes for both series, and Hang up shows for a
|
||||
Series 4. Series-specific controls follow the unit's own `/device/info`
|
||||
answer and drop when the serial, host or port is edited; config and
|
||||
call-home writes are off for both series until phases 5 and 4;
|
||||
Diagnostics needs a confirmed Series 3. Without a serial the page reads
|
||||
as before. The rules are pure functions in one marked block, tested
|
||||
through Node (`tests/test_webapp_device_routing.py`).
|
||||
**Server side, the same phase:** the legacy Series-3 writes and erase
|
||||
(`/device/config`, `/config/project`, `/events/erase`, `/rescue`,
|
||||
`POST /device/call_home`) refuse 409 before any write unless the unit
|
||||
answers as Series 3 (and as the named unit, given `serial=`). The stop
|
||||
tools stay exempt: 0x96/0x97 mean the same on both series.
|
||||
- ⚠ **The ring-path Runs A/B have not been run.** The page does not poll
|
||||
(every request is a click), SFM hangs up on RADIO RING, and Hang up
|
||||
releases a held line, but whether a call-home reaches THOR while SFM
|
||||
holds the line is unmeasured. Run them before serial mode is used on a
|
||||
unit that calls home to THOR, i.e. before this branch merges.
|
||||
- Of the items parked for 1c below: **CORS ordering** does not bite the
|
||||
page, which SFM serves itself (same origin); the **Series-4 mic** is not
|
||||
shown (the event list shows geophone peaks only). The rest are server-side
|
||||
and stay open.
|
||||
2. **Encoder + opcode guard + dry run + frame-reproduction tests.** Still
|
||||
nothing sent.
|
||||
(2026-10-22) "Dry run" in this phase means the **write plan**: the exact
|
||||
|
||||
Reference in new issue