docs: phase 1c -- the webapp by serial, and the Series-3 guard on legacy writes

- CLAUDE.md: a 1c entry under Where things stand (serial mode, what follows
  the unit's own answer, writes off until phases 4-5, the Node-run page tests)
  and the legacy-route guard in the REST API notes, with why the stop tools
  are exempt.
- Spec: the 1c build status; the ring-path Runs A/B are still owed before
  serial mode is used on a unit that calls home to THOR; which parked 1c items
  the page settles (CORS: same origin; the S4 mic is not shown).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-29 12:01:39 -04:00
1 parent c4cb979dfb
commit 073284fc88
2 files changed
+60 -1

No files matched your search

+36 -1
View File
@@ -164,7 +164,37 @@ Read this first when picking the project back up.
start's read-back waited out the ~30 s sensor check and re-sent the wake
(`9886422`, `ca5c401`; a monitoring MiniMate answers nothing until woken, and
nothing during its sensor check). Still owed before merge: #47 from dev, and
`persist_download` aligned with dev's waveform-time restamp (spec). Next: 1c.
`persist_download` aligned with dev's waveform-time restamp (spec).
- **Phase 1c: the SFM webapp by serial (2026-10-29), built; bench pass owed.**
`sfm/sfm_webapp.html` has a **Serial** field beside host/port. With one, the
Live tabs use the serial-based routes for both series: identify, status (now
with the unit's clock and event count), settings (read-only), the event list
with a Download per row (checked, stored, then opened from the store), and
audited start/stop (asks first, one send, shows the ChangeResult as it is).
Hang up appears for a Series 4. Every series-specific control follows the
unit's own `/device/info` answer, never the typed serial, and drops the
moment the serial, host or port is edited. Config and call-home **writes are
off for both series** (phases 5 and 4); Diagnostics is enabled only for a
confirmed Series 3. Without a serial every read behaves as before.
The page keeps every routing and button rule in one block of pure functions
between `/* <device-routing> */` markers, run through **Node** by
`tests/test_webapp_device_routing.py` (skipped when `node` is absent); a
static test fails if a `/device/` URL is built anywhere else.
**Server side:** the legacy Series-3 writes and erase -- `POST /device/config`
(and `/config/project`), `/events/erase`, `/rescue` (when it disables ACH or
erases), `POST /device/call_home` -- read the unit's serial (or reuse the one
`connect()` read) and refuse 409, nothing sent, unless it is Series 3 and,
when `serial=` was given, that unit. 0xA2 is CONFIRM ERASE on a MiniMate and
ends a call-home on a Micromate. The stop tools (legacy `monitor/start|stop`,
`stop_monitoring_blind`, `_slow_drip`, `_spam`) are exempt: 0x96/0x97 mean
the same on both series, and the blind tools must reach a unit too wedged to
answer.
⚠ **Before serial mode is used on a unit that calls home to THOR, run the
ring-path Runs A/B** (spec, *Open questions ... for the bench*): a held line
holds the modem's single TCP session. The page never polls (every request is
a click), SFM hangs up on RADIO RING, and **Hang up** releases the line at
once; whether a call-home still reaches THOR is unmeasured.
Next: the bench pass on BE9441 and UM20147, then phases 4 and 5.
- **✅ Phase 3: start / stop monitoring by serial (2026-10-23) — built,
reviewed, and bench-verified on UM20147 (2026-10-25).** Start acked in
0.46 s and read back as monitoring at the first 2 s poll (during the sensor
@@ -1582,6 +1612,11 @@ POST /device/hangup?host=1.2.3.4&tcp_port=9034 ← release a held Serie
nothing; `even_if_already=true` sends even when the unit is already in that state). A
`UM` serial on any other `/device/*` route is 501; any request taking the legacy
Series-3 path at a held Series-4 address is 409.
The legacy Series-3 writes and erase (`POST /device/config`, `/config/project`,
`/events/erase`, `/rescue`, `POST /device/call_home`) take an optional `serial=` and
refuse 409, nothing sent, when the unit at the address does not answer as Series 3
or is not the named unit. The stop tools (`monitor/start|stop` without a serial,
`stop_monitoring_blind`, `_slow_drip`, `_spam`) are exempt by design.
SFM must run a single uvicorn worker (locks and held lines are per process).
Server retries once on `ProtocolError` for TCP connections (handles cold-boot timing).