docs: phase 1c -- the webapp by serial, and the Series-3 guard on legacy writes

- CLAUDE.md: a 1c entry under Where things stand (serial mode, what follows
  the unit's own answer, writes off until phases 4-5, the Node-run page tests)
  and the legacy-route guard in the REST API notes, with why the stop tools
  are exempt.
- Spec: the 1c build status; the ring-path Runs A/B are still owed before
  serial mode is used on a unit that calls home to THOR; which parked 1c items
  the page settles (CORS: same origin; the S4 mic is not shown).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-29 12:01:39 -04:00
1 parent c4cb979dfb
commit 073284fc88
2 files changed
+60 -1

No files matched your search

@@ -490,6 +490,30 @@ Each safety piece arrives with its first real use, so nothing sits untested.
address answer 503 + `Retry-After` until it expires, and
`POST /device/hangup` clears it, with its length taken from Run A. If
THOR gets the call anyway, no cool-down is needed.
- **Built 2026-10-29** (plan `docs/superpowers/plans/2026-10-28-sfm-phase1c-webapp.md`).
A Serial field beside host/port; with one, identify, status, settings
(read-only), events (a Download per row) and audited start/stop go
through the serial routes for both series, and Hang up shows for a
Series 4. Series-specific controls follow the unit's own `/device/info`
answer and drop when the serial, host or port is edited; config and
call-home writes are off for both series until phases 5 and 4;
Diagnostics needs a confirmed Series 3. Without a serial the page reads
as before. The rules are pure functions in one marked block, tested
through Node (`tests/test_webapp_device_routing.py`).
**Server side, the same phase:** the legacy Series-3 writes and erase
(`/device/config`, `/config/project`, `/events/erase`, `/rescue`,
`POST /device/call_home`) refuse 409 before any write unless the unit
answers as Series 3 (and as the named unit, given `serial=`). The stop
tools stay exempt: 0x96/0x97 mean the same on both series.
- ⚠ **The ring-path Runs A/B have not been run.** The page does not poll
(every request is a click), SFM hangs up on RADIO RING, and Hang up
releases a held line, but whether a call-home reaches THOR while SFM
holds the line is unmeasured. Run them before serial mode is used on a
unit that calls home to THOR, i.e. before this branch merges.
- Of the items parked for 1c below: **CORS ordering** does not bite the
page, which SFM serves itself (same origin); the **Series-4 mic** is not
shown (the event list shows geophone peaks only). The rest are server-side
and stay open.
2. **Encoder + opcode guard + dry run + frame-reproduction tests.** Still
nothing sent.