fix(sfm): a monitoring MiniMate's call-home says 'stop monitoring first', not 'unknown(0x6E)'
Measured at the bench 2026-11-03 (BE9441): while monitoring, a MiniMate answers
the 0x2C call-home read with its DEVICE-INFO block ('Instantel', 'MiniMate Plus',
its serial) -- as it answers 1A -- and idle again, minutes later, the call-home
block. SFM writes back only a block it just read, so a monitoring MiniMate's
call-home cannot be changed; the change core already refused (byte 5 read as
'unknown(0x6E)', nothing sent), but said so cryptically.
- minimateplus.protocol.is_call_home_block(raw): the block starts with its own
length 0x7C and is N (or N + 2) bytes unescaped; the device-info block fails it.
- The Series-3 change raises UnitStateUnknown (409) with 'did not return its
call-home settings -- a MiniMate answers the call-home read with its
device-info block while monitoring; stop monitoring first ... nothing sent',
for a dry run too. call_home_state returns enabled = None with that reason.
- The page's callHomeRows shows the reason in place of 'Unknown (byte 5 = ...)'.
A blind write while monitoring stays untested on purpose.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
9820a5389f
commit
5326e99ac2
5 files changed
+71
-6
No files matched your search
@@ -204,8 +204,9 @@ function serialPanes(bySerial, settingsRead) {
|
||||
// enable byte never measured -- shown with the byte, never as On or Off.
|
||||
function callHomeRows(state) {
|
||||
const s = state || {};
|
||||
const d = s.detail || {};
|
||||
const sw = s.enabled === true ? 'On' : s.enabled === false ? 'Off'
|
||||
: `Unknown (byte 5 = ${(s.detail || {}).byte5 ?? '?'})`;
|
||||
: d.reason || `Unknown (byte 5 = ${d.byte5 ?? '?'})`;
|
||||
return [['Call-home', sw], ['Dial string', s.dial_string || '—'], ['Series', s.series]];
|
||||
}
|
||||
/* </device-routing> */
|
||||
Reference in new issue
Block a user