feat(micromate): get_setup() -- the setup block decoded, checksum-verified, and read off a real unit

MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup:
record mode, sample rate, histogram interval, pre-trigger, stop mode, record
time, auto-stop, active sensors, trigger sources, the three geophone trigger
levels, mic type and (linear) mic trigger, job number, scaled distance, and
the four notes.  MEASURED FIELDS ONLY -- everything graded inferred or
unknown in the reference stays in .raw.

micromate/setup_block.py holds the decode as pure functions (no I/O), plus
crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E.  A failed checksum
raises SetupChecksumError (a ProtocolError) unless verify=False; a short
block raises either way.

Two things the decoder gets right that a naive one would not:
- the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6,
  which hold the stored settings of whichever mic is NOT fitted;
- distance and charge weight convert back with the unit's own 3.2808 and
  2.21, so 45 lb entered on the unit reads 45.0, not 44.89.

TESTS: 69 new.  15 real fixtures (2,103 B each) -- 14 UM20147 reads from the
10-17/10-19 keypad passes, chosen so every field takes at least two values,
plus UM12947's read from Thor's 9-24 capture (other firmware line).
Expected values are what the operator read off the unit's screen, never the
decoder's own output.  Fixtures force-added, per the tests/fixtures/
convention.  Full suite 541 passed; the 16 pre-existing failures
(test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged.

VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded
setup; against UM20147 every line matched the unit's screen (Brian, 10-19).

Also: the scratch harness uses the library checksum and checks all three
blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the
likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first
one this code has met").

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-19 18:20:25 -04:00
1 parent a74d3c9b00
commit b3aff4ed66
22 files changed
+622 -35

No files matched your search

+76
View File
@@ -22,6 +22,7 @@ shrink or disappear.
from __future__ import annotations
import datetime
import math
from dataclasses import dataclass, field
from typing import Any, Dict, Optional, Tuple
@@ -480,6 +481,81 @@ class MicromateState:
return " ".join(bits)
_RECORD_MODES = {0x01: "Waveform", 0x02: "Waveform Manual", 0x03: "Histogram", 0x04: "Histogram Combo"}
# The unit's OWN conversion constants, identified bit-exactly from what it
# stored for keypad entries (2026-10-19). Not the textbook 3.28084 / 2.20462:
# convert back with these, or 45 lb entered on the unit reads as 44.89 lb.
_FT_PER_M = 3.2808
_LB_PER_KG = 2.21
_PA_PER_PSI = 6894.757
_P_REF_PA = 20e-6 # dB re 20 µPa
@dataclass
class MicromateSetup:
"""A unit's active setup, from ``SUB 0x1A`` — see ``micromate/setup_block.py``.
**Measured fields only.** Each was located by changing that one setting on a
unit's keypad and watching the bytes; anything graded inferred or unknown in
the protocol reference is left in ``raw`` rather than guessed at here.
⚠ This is what the unit is set to *right now* — including unsaved edits if
someone is in its setup menu, because ``0x1A`` reads the keypad's edit
buffer. Values are in the units the unit stores, whatever it displays:
in/s, psi, metres, kilograms.
"""
name: str # ⚠ ".MMB" after a keypad save, ".mmb" after a load
record_mode: int # see record_mode_name
sample_rate: int # samples per second
histogram_interval_s: int
pretrigger_s: float # positive; the unit stores it negative
auto_record_stop: bool # False = Fixed record time
record_time_s: float
auto_stop_after_s: int # quiet time before an Auto stop
geophones_active: bool
mic_active: bool
trigger_on_geophones: bool
trigger_on_mic: bool
geo_trigger_ips: Tuple[float, float, float] # Tran, Vert, Long
mic_type: str # "linear" | "sound_level" | "unknown (<code>)"
mic_trigger_psi: Optional[float] # linear mic only; SLM units not measured
job_number_enabled: bool
job_number: int # kept while switched off
scaled_distance_enabled: bool
distance_m: float
charge_weight_kg: float
notes: Dict[str, str] # label -> value, in the unit's order
raw: bytes = field(default=b"", repr=False) # the 2,092-byte content
@property
def record_mode_name(self) -> str:
return _RECORD_MODES.get(self.record_mode, f"unknown (0x{self.record_mode:02x})")
@property
def mic_trigger_db(self) -> Optional[float]:
"""dB re 20 µPa. Matches the unit's screen to ±0.001 dB on 131 and 140."""
if not self.mic_trigger_psi:
return None
return 20.0 * math.log10(self.mic_trigger_psi * _PA_PER_PSI / _P_REF_PA)
@property
def distance_ft(self) -> float:
return self.distance_m * _FT_PER_M
@property
def charge_weight_lb(self) -> float:
return self.charge_weight_kg * _LB_PER_KG
@property
def scaled_distance(self) -> Optional[float]:
"""ft / √lb, as the unit computes it for display. It is not stored."""
if self.charge_weight_kg <= 0:
return None
return self.distance_ft / math.sqrt(self.charge_weight_lb)
@dataclass
class MicromateEventRef:
"""One entry in a unit's event chain, from `1E`/`1F` and optionally `0x0C`.