feat(micromate): get_setup() -- the setup block decoded, checksum-verified, and read off a real unit

MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup:
record mode, sample rate, histogram interval, pre-trigger, stop mode, record
time, auto-stop, active sensors, trigger sources, the three geophone trigger
levels, mic type and (linear) mic trigger, job number, scaled distance, and
the four notes.  MEASURED FIELDS ONLY -- everything graded inferred or
unknown in the reference stays in .raw.

micromate/setup_block.py holds the decode as pure functions (no I/O), plus
crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E.  A failed checksum
raises SetupChecksumError (a ProtocolError) unless verify=False; a short
block raises either way.

Two things the decoder gets right that a naive one would not:
- the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6,
  which hold the stored settings of whichever mic is NOT fitted;
- distance and charge weight convert back with the unit's own 3.2808 and
  2.21, so 45 lb entered on the unit reads 45.0, not 44.89.

TESTS: 69 new.  15 real fixtures (2,103 B each) -- 14 UM20147 reads from the
10-17/10-19 keypad passes, chosen so every field takes at least two values,
plus UM12947's read from Thor's 9-24 capture (other firmware line).
Expected values are what the operator read off the unit's screen, never the
decoder's own output.  Fixtures force-added, per the tests/fixtures/
convention.  Full suite 541 passed; the 16 pre-existing failures
(test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged.

VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded
setup; against UM20147 every line matched the unit's screen (Brian, 10-19).

Also: the scratch harness uses the library checksum and checks all three
blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the
likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first
one this code has met").

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-19 18:20:25 -04:00
1 parent a74d3c9b00
commit b3aff4ed66
22 files changed
+622 -35

No files matched your search

+10 -21
View File
@@ -52,6 +52,7 @@ sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from bridges.mm_client_check import StdlibSerial # noqa: E402
from micromate.client import MicromateClient # noqa: E402
from micromate.setup_block import crc_ok # noqa: E402
from minimateplus.transport import TcpTransport # noqa: E402
SNAP_ROOT = Path(__file__).resolve().parent / "mm_config_snaps"
@@ -138,28 +139,16 @@ def _interps(a: bytes, b: bytes, off: int, run: int) -> list[str]:
return out
def crc16_aug_ccitt(data: bytes) -> int:
"""CRC-16/AUG-CCITT: poly 0x1021, init 0x1D0F, no reflection, xorout 0."""
c = 0x1D0F
for x in data:
c ^= x << 8
for _ in range(8):
c = ((c << 1) ^ 0x1021) & 0xFFFF if c & 0x8000 else (c << 1) & 0xFFFF
return c
# Blocks that carry the config checksum (micromate.setup_block.crc_ok): N =
# content[0:2], CRC-16/AUG-CCITT over [0:N-2] stored at [N:N+2]. 0x2C has none.
CRC_BLOCKS = {"1A_compliance", "08_event_index", "2E_trigger"}
def crc_status_1a(raw: bytes) -> str:
"""Check 0x1A's trailer: CRC over content[0:2088], stored BE at [2090:2092].
Found 2026-10-17 from one keypad diff and confirmed on 23 snapshots plus
UM12947's 9-24 capture. A mismatch means a short or corrupt read -- or
that the layout is not what this assumes, which is worth knowing too.
"""
def crc_status(raw: bytes) -> str:
"""A mismatch means a short or corrupt read -- or a block this rule misses."""
c = raw[CONTENT:]
if len(c) < 2092:
return f"CRC n/a (content {len(c)} B < 2092)"
want, got = crc16_aug_ccitt(c[:2088]), int.from_bytes(c[2090:2092], "big")
return f"CRC ok ({got:04x})" if want == got else f"CRC MISMATCH computed {want:04x}, stored {got:04x}"
stored = c[int.from_bytes(c[0:2], "big"):][:2].hex() if len(c) >= 2 else "--"
return f"CRC ok ({stored})" if crc_ok(c) else f"CRC MISMATCH (stored {stored})"
def _runs(a: bytes, b: bytes, ignore: set[int]) -> list[tuple[int, int]]:
@@ -314,8 +303,8 @@ def cmd_watch(mm: MicromateClient, serial: str, interval: float,
f"{a[off:off + run].hex()} -> {b[off:off + run].hex()}")
for line in _interps(a, b, off, run):
print(f" {line}")
if name == "1A_compliance":
print(f" {crc_status_1a(cur[name])}")
if name in CRC_BLOCKS:
print(f" {crc_status(cur[name])}")
print(flush=True)
prev = cur
except KeyboardInterrupt: