feat(micromate): get_setup() -- the setup block decoded, checksum-verified, and read off a real unit

MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup:
record mode, sample rate, histogram interval, pre-trigger, stop mode, record
time, auto-stop, active sensors, trigger sources, the three geophone trigger
levels, mic type and (linear) mic trigger, job number, scaled distance, and
the four notes.  MEASURED FIELDS ONLY -- everything graded inferred or
unknown in the reference stays in .raw.

micromate/setup_block.py holds the decode as pure functions (no I/O), plus
crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E.  A failed checksum
raises SetupChecksumError (a ProtocolError) unless verify=False; a short
block raises either way.

Two things the decoder gets right that a naive one would not:
- the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6,
  which hold the stored settings of whichever mic is NOT fitted;
- distance and charge weight convert back with the unit's own 3.2808 and
  2.21, so 45 lb entered on the unit reads 45.0, not 44.89.

TESTS: 69 new.  15 real fixtures (2,103 B each) -- 14 UM20147 reads from the
10-17/10-19 keypad passes, chosen so every field takes at least two values,
plus UM12947's read from Thor's 9-24 capture (other firmware line).
Expected values are what the operator read off the unit's screen, never the
decoder's own output.  Fixtures force-added, per the tests/fixtures/
convention.  Full suite 541 passed; the 16 pre-existing failures
(test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged.

VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded
setup; against UM20147 every line matched the unit's screen (Brian, 10-19).

Also: the scratch harness uses the library checksum and checks all three
blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the
likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first
one this code has met").

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-19 18:20:25 -04:00
1 parent a74d3c9b00
commit b3aff4ed66
22 files changed
+622 -35

No files matched your search

Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
+45
View File
@@ -22,6 +22,7 @@ sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from micromate.client import CONTENT, MicromateClient, _content, _cstring
from micromate.framing import ETX, STX, checksum, stuff
from micromate.protocol import ProtocolError
from micromate.setup_block import SetupChecksumError
FLAGS_CB, FLAGS_THOR = 0xC5, 0x03
@@ -491,3 +492,47 @@ def test_the_four_extra_bd_bytes_are_not_all_zero():
"""
assert _content(MS_BD_MONITORING)[44:] == bytes.fromhex("0fa00004")
assert _content(MS_IDLE)[44:] == b"", "the CB block has no such tail"
# ── get_setup() ───────────────────────────────────────────────────────────────
# Decoding itself is covered field by field in test_micromate_setup.py; these
# check the client's read, its framing round trip and the verify switch.
SETUP_FIXTURES = os.path.join(os.path.dirname(os.path.abspath(__file__)), "fixtures", "micromate-setup")
def _setup_read(name: str) -> bytes:
with open(os.path.join(SETUP_FIXTURES, f"{name}.bin"), "rb") as f:
return f.read()
def test_get_setup_is_one_read_of_0x1a():
"""One frame -- not Series III's four-frame compliance sequence."""
mm, t = client([frame(0xE5, _setup_read("um20147_baseline"))])
mm.get_setup()
assert [w[5] for w in t.written] == [0x1A]
def test_get_setup_survives_a_literal_dle_through_the_framing():
"""4096 sps puts 0x10 in the payload, which the unit must escape on the wire
and the parser must unescape. Wrong either way and the rate reads wrong or
the CRC fails."""
mm, _ = client([frame(0xE5, _setup_read("um20147_4096sps"))])
s = mm.get_setup()
assert s.sample_rate == 4096
assert s.raw == _setup_read("um20147_4096sps")[CONTENT:]
def test_get_setup_raises_on_a_corrupt_read_by_default():
data = bytearray(_setup_read("um20147_baseline"))
data[CONTENT + 5] = 0x05
mm, _ = client([frame(0xE5, bytes(data))])
with pytest.raises(SetupChecksumError):
mm.get_setup()
def test_get_setup_verify_false_returns_the_corrupt_read():
data = bytearray(_setup_read("um20147_baseline"))
data[CONTENT + 5] = 0x05
mm, _ = client([frame(0xE5, bytes(data))])
assert mm.get_setup(verify=False).record_mode == 0x05
+272
View File
@@ -0,0 +1,272 @@
"""
Tests for micromate/setup_block.py — the Micromate setup block (SUB 0x1A) decoder.
Every fixture is a real read off a unit, taken with scratch/mm_config_diff.py
while an operator changed settings on the unit's own keypad, 2026-10-17/19.
**Expected values are what the operator read off the unit's screen**, recorded in
docs/micromate_protocol_reference.md — never values computed by this decoder.
A test whose expectation came from the code under test passes whatever the code
does.
Fixtures are 2,103-byte `0x1A` response data: an 11-byte prefix, then the
2,092-byte content the decoder reads. `um12947_2026-09-24.bin` is a second unit
on the other firmware line, cut from Thor's 9-24 "send TEST1" capture.
"""
from __future__ import annotations
import os
import sys
from pathlib import Path
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from micromate.protocol import ProtocolError # noqa: E402
from micromate.setup_block import SetupChecksumError, crc_ok, decode_setup # noqa: E402
FIXTURES = Path(__file__).parent / "fixtures" / "micromate-setup"
ALL_FIXTURES = sorted(FIXTURES.glob("*.bin"))
# Small real blocks for the generic checksum rule (content only, prefix stripped).
# 0x08 preferences, Imperial and Metric -- UM20147, 2026-10-19 17:07 / 17:14.
PREFS_IMPERIAL = bytes.fromhex(
"00580900000000000000000000000000000000000000000000000000000000000000000000"
"000000000100010001000100000000000000010001000000000000000000000000000000"
"000002000000000000000200000000b42f"
)
PREFS_METRIC = bytes.fromhex(
"00580900000000000000000000000000000000000000000000000000000000010000000000"
"000000000100010001000100000000000000010001000000000000000000000000000000"
"000002000000000000000200000000911a"
)
# 0x2E, same session.
BLOCK_2E = bytes.fromhex("001ad50000010000000000000000000000000000000000000000141a")
def content_of(name: str) -> bytes:
return (FIXTURES / f"{name}.bin").read_bytes()[11:]
# ── The checksum rule ─────────────────────────────────────────────────────────
def test_fixtures_are_present():
"""15 fixtures; a missing directory would otherwise make the parametrised
tests below collect nothing and pass vacuously."""
assert len(ALL_FIXTURES) == 15
@pytest.mark.parametrize("path", ALL_FIXTURES, ids=lambda p: p.stem)
def test_every_real_setup_read_passes_its_checksum(path):
assert crc_ok(path.read_bytes()[11:])
@pytest.mark.parametrize(
"block", [PREFS_IMPERIAL, PREFS_METRIC, BLOCK_2E], ids=["0x08-imperial", "0x08-metric", "0x2E"]
)
def test_the_rule_is_the_blocks_own_length_not_the_setup_size(block):
"""One rule covers three blocks: N = content[0:2], CRC over [0:N-2] stored at
[N:N+2]. An implementation hard-wired to the setup block's 2088 fails here."""
assert crc_ok(block)
@pytest.mark.parametrize("offset", [5, 144, 1738, 2087], ids=["mode", "note", "trigger", "last-covered"])
def test_one_changed_byte_fails_the_checksum(offset):
c = bytearray(content_of("um20147_baseline"))
c[offset] ^= 0x01
assert not crc_ok(bytes(c))
def test_a_changed_trailer_fails_the_checksum():
c = bytearray(content_of("um20147_baseline"))
c[2091] ^= 0x01
assert not crc_ok(bytes(c))
@pytest.mark.parametrize("n", [0, 1, 2, 100, 2091], ids=lambda n: f"{n}B")
def test_a_block_too_short_for_its_own_length_fails(n):
"""A truncated read must read as bad, never raise IndexError and never pass."""
assert not crc_ok(content_of("um20147_baseline")[:n])
# ── Fields: every value below is what the operator read off the screen ────────
@pytest.mark.parametrize(
"name, mode_code, mode_name",
[
("um20147_waveform", 0x01, "Waveform"),
("um20147_waveform_manual", 0x02, "Waveform Manual"),
("um20147_histogram_300s", 0x03, "Histogram"),
("um20147_baseline", 0x04, "Histogram Combo"),
],
)
def test_record_mode(name, mode_code, mode_name):
"""Same codes as Series III, one byte later than the S3 analogy put them.
The keypad menu order is 03 04 01 02, so an off-by-one enum reads wrong here."""
s = decode_setup(content_of(name))
assert s.record_mode == mode_code
assert s.record_mode_name == mode_name
@pytest.mark.parametrize(
"name, rate",
[("um20147_baseline", 1024), ("um20147_waveform_manual", 2048), ("um20147_4096sps", 4096)],
)
def test_sample_rate(name, rate):
"""4096 puts a literal 0x10 (DLE) at content[6] -- the case that shifted
every later field by one byte on Series III."""
assert decode_setup(content_of(name)).sample_rate == rate
@pytest.mark.parametrize("name, seconds", [("um20147_baseline", 2), ("um20147_histogram_300s", 300)])
def test_histogram_interval(name, seconds):
"""300 = 01 2c: the high byte is what proves the field is two bytes wide."""
assert decode_setup(content_of(name)).histogram_interval_s == seconds
@pytest.mark.parametrize("name, seconds", [("um20147_baseline", 1.0), ("um20147_pretrig025_auto", 0.25)])
def test_pretrigger_is_reported_positive(name, seconds):
"""Stored as NEGATIVE seconds (-1.0 / -0.25); the screen shows 1.0 / 0.25."""
assert decode_setup(content_of(name)).pretrigger_s == seconds
@pytest.mark.parametrize(
"name, auto, record_time, auto_stop",
[("um20147_baseline", False, 10.0, 3), ("um20147_pretrig025_auto", True, 11.0, 1)],
)
def test_record_time_window(name, auto, record_time, auto_stop):
s = decode_setup(content_of(name))
assert s.auto_record_stop is auto
assert s.record_time_s == record_time
assert s.auto_stop_after_s == auto_stop
@pytest.mark.parametrize(
"name, geo_on, mic_on, trig_geo, trig_mic",
[
("um20147_baseline", True, True, True, True),
("um20147_geo_only", True, False, True, False),
("um20147_mic_only", False, True, False, True),
("um20147_geo_trigger_off", True, True, False, True),
],
)
def test_active_sensors_and_trigger_sources_are_separate_masks(name, geo_on, mic_on, trig_geo, trig_mic):
"""content[25] is which sensors are on, content[29] which may trigger.
geo_trigger_off has both sensors on but only the mic triggering -- a decoder
reading both from one byte gets that fixture wrong."""
s = decode_setup(content_of(name))
assert (s.geophones_active, s.mic_active) == (geo_on, mic_on)
assert (s.trigger_on_geophones, s.trigger_on_mic) == (trig_geo, trig_mic)
@pytest.mark.parametrize(
"name, level",
[("um20147_baseline", 0.5), ("um20147_waveform_manual", 0.6), ("um12947_2026-09-24", 0.3)],
)
def test_geophone_trigger_level_per_channel(name, level):
s = decode_setup(content_of(name))
assert s.geo_trigger_ips == pytest.approx((level, level, level), abs=1e-6)
@pytest.mark.parametrize("name, db", [("um20147_baseline", 131.0), ("um20147_mic_140db", 140.0)])
def test_linear_mic_trigger_is_psi_and_reads_back_as_the_screens_db(name, db):
s = decode_setup(content_of(name))
assert s.mic_type == "linear"
assert s.mic_trigger_psi is not None
assert s.mic_trigger_db == pytest.approx(db, abs=0.01)
def test_the_mic_comes_from_block_4_not_from_the_stored_setups():
"""Block 4 is the ACTIVE mic; blocks 5/6 are stored linear/SLM settings.
With a sound-level mic selected, block 5 still holds a linear mic -- read it
and the decoder reports a mic that is not plugged in."""
s = decode_setup(content_of("um20147_sound_level_mic"))
assert s.mic_type == "sound_level"
assert s.mic_trigger_psi is None # its unit is not measured; not exposed
assert s.mic_trigger_db is None
@pytest.mark.parametrize(
"name, enabled, number",
[
("um20147_baseline", False, 0),
("um20147_job_1234", True, 1234),
("um20147_scaled_distance", False, 1234), # switched off, number kept
],
)
def test_job_number(name, enabled, number):
s = decode_setup(content_of(name))
assert s.job_number_enabled is enabled
assert s.job_number == number
def test_scaled_distance_uses_the_units_own_conversion_constants():
"""Entered as 123 ft and 45 lb; the screen then showed scaled distance 18.34.
Stored as metres and kg via ft / 3.2808 and lb / 2.21 -- converting back with
the textbook 2.20462 shows 44.89 lb, not what the operator typed."""
s = decode_setup(content_of("um20147_scaled_distance"))
assert s.scaled_distance_enabled is True
assert s.distance_ft == pytest.approx(123.0, abs=1e-3)
assert s.charge_weight_lb == pytest.approx(45.0, abs=1e-3)
assert s.scaled_distance == pytest.approx(18.34, abs=0.005)
def test_scaled_distance_off_with_no_charge_weight():
s = decode_setup(content_of("um20147_baseline"))
assert s.scaled_distance_enabled is False
assert s.scaled_distance is None # no charge weight: nothing to divide by
def test_notes_are_label_value_pairs():
s = decode_setup(content_of("um20147_location_bench01"))
assert list(s.notes) == ["Location", "Client", "Company", "General Notes"]
assert s.notes["Location"] == "BENCH01"
def test_a_second_unit_on_the_other_firmware_line():
"""UM12947 (11.0CB), cut from Thor's 9-24 capture: a different unit, firmware
and setup. Strings are this job's notes as the read returned them."""
s = decode_setup(content_of("um12947_2026-09-24"))
assert s.name == "Univ of Pitt-1st Yr. Housing-Loc1 Ruskin.mmb"
assert s.notes == {
"Location": "Univ of Pitt-1st Yr Housing-Loc1 Ruskin",
"Client": "PJ Dick Inc.",
"Company": "Terra-Mechanics, Inc. - Harrison",
"General Notes": "Loc#1-Univ of Pitt. - Ruskin Hall",
}
def test_raw_is_the_content():
c = content_of("um20147_baseline")
assert decode_setup(c).raw == c
# ── Errors ────────────────────────────────────────────────────────────────────
def test_a_corrupt_block_raises_rather_than_decoding_garbage():
c = bytearray(content_of("um20147_baseline"))
c[5] = 0x05 # a mode byte no keypad produces
with pytest.raises(SetupChecksumError):
decode_setup(bytes(c))
def test_a_checksum_error_is_a_protocol_error():
"""Callers already catching ProtocolError around a read keep working."""
assert issubclass(SetupChecksumError, ProtocolError)
def test_verify_false_decodes_a_corrupt_block_anyway():
"""For diagnosis: see what a bad read contained instead of only that it was bad."""
c = bytearray(content_of("um20147_baseline"))
c[5] = 0x05
s = decode_setup(bytes(c), verify=False)
assert s.record_mode_name == "unknown (0x05)"
@pytest.mark.parametrize("verify", [True, False])
def test_a_short_block_raises_even_without_verify(verify):
"""verify=False skips the checksum, never the bounds -- a short read would
otherwise decode as zeros, or raise an IndexError from deep in a slice."""
with pytest.raises(ProtocolError, match="2092"):
decode_setup(content_of("um20147_baseline")[:1900], verify=verify)