feat(micromate): get_setup() -- the setup block decoded, checksum-verified, and read off a real unit

MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup:
record mode, sample rate, histogram interval, pre-trigger, stop mode, record
time, auto-stop, active sensors, trigger sources, the three geophone trigger
levels, mic type and (linear) mic trigger, job number, scaled distance, and
the four notes.  MEASURED FIELDS ONLY -- everything graded inferred or
unknown in the reference stays in .raw.

micromate/setup_block.py holds the decode as pure functions (no I/O), plus
crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E.  A failed checksum
raises SetupChecksumError (a ProtocolError) unless verify=False; a short
block raises either way.

Two things the decoder gets right that a naive one would not:
- the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6,
  which hold the stored settings of whichever mic is NOT fitted;
- distance and charge weight convert back with the unit's own 3.2808 and
  2.21, so 45 lb entered on the unit reads 45.0, not 44.89.

TESTS: 69 new.  15 real fixtures (2,103 B each) -- 14 UM20147 reads from the
10-17/10-19 keypad passes, chosen so every field takes at least two values,
plus UM12947's read from Thor's 9-24 capture (other firmware line).
Expected values are what the operator read off the unit's screen, never the
decoder's own output.  Fixtures force-added, per the tests/fixtures/
convention.  Full suite 541 passed; the 16 pre-existing failures
(test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged.

VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded
setup; against UM20147 every line matched the unit's screen (Brian, 10-19).

Also: the scratch harness uses the library checksum and checks all three
blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the
likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first
one this code has met").

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-19 18:20:25 -04:00
1 parent a74d3c9b00
commit b3aff4ed66
22 files changed
+622 -35

No files matched your search

+45
View File
@@ -22,6 +22,7 @@ sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from micromate.client import CONTENT, MicromateClient, _content, _cstring
from micromate.framing import ETX, STX, checksum, stuff
from micromate.protocol import ProtocolError
from micromate.setup_block import SetupChecksumError
FLAGS_CB, FLAGS_THOR = 0xC5, 0x03
@@ -491,3 +492,47 @@ def test_the_four_extra_bd_bytes_are_not_all_zero():
"""
assert _content(MS_BD_MONITORING)[44:] == bytes.fromhex("0fa00004")
assert _content(MS_IDLE)[44:] == b"", "the CB block has no such tail"
# ── get_setup() ───────────────────────────────────────────────────────────────
# Decoding itself is covered field by field in test_micromate_setup.py; these
# check the client's read, its framing round trip and the verify switch.
SETUP_FIXTURES = os.path.join(os.path.dirname(os.path.abspath(__file__)), "fixtures", "micromate-setup")
def _setup_read(name: str) -> bytes:
with open(os.path.join(SETUP_FIXTURES, f"{name}.bin"), "rb") as f:
return f.read()
def test_get_setup_is_one_read_of_0x1a():
"""One frame -- not Series III's four-frame compliance sequence."""
mm, t = client([frame(0xE5, _setup_read("um20147_baseline"))])
mm.get_setup()
assert [w[5] for w in t.written] == [0x1A]
def test_get_setup_survives_a_literal_dle_through_the_framing():
"""4096 sps puts 0x10 in the payload, which the unit must escape on the wire
and the parser must unescape. Wrong either way and the rate reads wrong or
the CRC fails."""
mm, _ = client([frame(0xE5, _setup_read("um20147_4096sps"))])
s = mm.get_setup()
assert s.sample_rate == 4096
assert s.raw == _setup_read("um20147_4096sps")[CONTENT:]
def test_get_setup_raises_on_a_corrupt_read_by_default():
data = bytearray(_setup_read("um20147_baseline"))
data[CONTENT + 5] = 0x05
mm, _ = client([frame(0xE5, bytes(data))])
with pytest.raises(SetupChecksumError):
mm.get_setup()
def test_get_setup_verify_false_returns_the_corrupt_read():
data = bytearray(_setup_read("um20147_baseline"))
data[CONTENT + 5] = 0x05
mm, _ = client([frame(0xE5, bytes(data))])
assert mm.get_setup(verify=False).record_mode == 0x05