docs(spec): phase 5 -- the Micromate schedule check; work hours is next

A scheduled start loads the setup it names, so a change to another
setup would be undone at the next start: read schedule.dat and refuse
that case.  Configurable work-hours recording, without THOR's scheduler
or setup files, is the agreed next project.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 18:35:29 -05:00
1 parent 0238e4d3f3
commit dba891d504
1 file changed
+18
@@ -45,6 +45,13 @@ changing the unit or a file is not.
- Restarting monitoring. **Brian presses Start**, as today; SFM never restarts on
its own.
- Setting the unit's clock. That is a later call-home receiver rule.
- **Writing the Micromate scheduler.** Next project, agreed 2026-11-03:
"record during work hours" as a plain, **configurable** setting on the unit's
page, both series, no schedule library and no setup files. On the Micromate,
it relies on the firmware's setup-less scheduler start (found in the firmware,
never sent; one bench session). On the MiniMate, its own timer setting
(undecoded). Brian's dad despises THOR's scheduler; Brian is willing to retire
it in SFM.
- Fields not yet decoded. "Any and all" grows as decoding grows.
**Anti-goals: things that would make it a failure even if it "works"**
@@ -264,6 +271,17 @@ intervals 2/5/15/60/300/900 s, and each series' measured mode codes.
rewrites the setup the unit is running, in place, under its own name. It
never asks for a file or a name, and never creates one. The name may show as
a read-only detail, since the unit's screen shows it.
- **The scheduler can undo a change (Brian, 2026-11-03, with THOR's Manage
Schedules screen).** Work-hours Micromates run a THOR schedule, e.g. Start
Monitoring 07:00 with setup `Mele-PWSA-Carroll -Loc 4`, stop 18:30, repeat
daily. THOR sends the schedule with its setup, and each scheduled start loads
the setup it names. So the preview and the send read `schedule.dat` (format
decoded, reference *The schedule record format*), read-only. A start action
naming a setup other than the one being changed blocks the send: "this unit's
schedule loads <name> at 07:00, which would replace this change." When the
schedule names the active setup (the usual case after a scheduled start), the
change survives, and the preview says when the next scheduled start is.
SFM never writes the schedule in this phase.
- The name comes from the `0x41` read, unstripped.
- Refuse `factory.MMB` and any target that is not the active setup (spec). The
refusal says it plainly: "this unit is running its factory setup; load any