serversdownandClaude Opus 5.5 3564c4a744 docs: phase 5 benched on both series (2026-11-04)
Both protocol references, the spec's bench section and CLAUDE.md record
the bench: every settings change acknowledged, read back and confirmed on
the unit's screen, both units restored byte for byte; the escaped-
checksum stray byte (fixed); a MiniMate's open setup menu writes its
whole-block copy back on Cancel or Save, losing a remote change; the
alarm write at channel +38; [26:28] re-set by the unit while monitoring;
the first Micromate setup push with the unit's CRC equal to SFM's; the
Micromate scheduler switch in none of the blocks SFM reads.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:16:40 -05:00
serversdownandClaude Opus 5.5 385716d8e1 feat(webapp): edit a unit's settings by serial: preview, send, read back
The Config tab by serial is now the unit's edit form, headed 'On the
unit <serial> -- read HH:MM' and built from the server's editable
fields.  Preview runs a dry run and shows old -> new, notes and anything
that blocks the change; Send (confirm) sends exactly what was previewed,
with its revision, then shows what the unit now holds and re-reads it.
An edit after a preview disables Send until the next preview.  The
by-host form loses its write button; the read stays.  Logic in
device_routing.js (Node-tested), glue in sfm_webapp.js, no inline JS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:57:17 -05:00
serversdownandClaude Opus 5.5 e3a77e421d docs(spec,plan): phase 5 -- the units' own limits, from Instantel's manuals
Brian: use the actual unit limits, not what has been used in the past.
Trigger 0.005-10 in/s in 0.001 steps (capped by the range), record time
1-90 s (Micromate) or the MiniMate manual's 1 MB table by sample rate
(13 s in Histogram Combo), job number 1-9999.  The read-back reports any
value a unit does not take.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 19:30:07 -05:00
serversdownandClaude Opus 5.5 dba891d504 docs(spec): phase 5 -- the Micromate schedule check; work hours is next
A scheduled start loads the setup it names, so a change to another
setup would be undone at the next start: read schedule.dat and refuse
that case.  Configurable work-hours recording, without THOR's scheduler
or setup files, is the agreed next project.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:35:29 -05:00
serversdownandClaude Opus 5.5 0238e4d3f3 docs(spec): phase 5 -- changing a unit's settings by serial
Brian's intent (UM6047's trigger, notes typos, the backup unit), the
flow, the first-version fields, and what is measured: Series 3's
compliance block has Series 4's 0x1A layout; a whole 1A read assembles
to the 2,090 bytes Blastware writes back (exact on both 10-26 writes);
Blastware writes 00 00 at [26:28] and a per-unit constant after the
block.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:12:14 -05:00