READ_SUBS catalogues every read; a SUB in neither table is refused, and
allowed_writes may only name catalogued writes. Tables are MappingProxyType,
_send checks the exact bytes it writes, check_transmit documents precedence.
Tests cover unknown opcodes, concatenation smuggling and table immutability.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
micromate/opcodes.py holds WRITE_SUBS and the cross-series collision 0xA2.
MicromateProtocol._send reads the SUB of the bytes about to go out
(framing.request_sub) and refuses any write SUB not in allowed_writes, and
0xA2 unconditionally. Docstrings now say the reads-only policy is enforced.
request_sub also refuses any frame not in canonical form
(stuff(unstuff(body)) == body): an interior unescaped 02/03/04, a 10 XX
outside {02,03,04,10}, or a trailing lone DLE. What the gate checks is then
exactly what the unit parses.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
tests/fixtures/ is gitignored, so these were never committed. Since phase 1b
the test fakes read them, so on a fresh clone every test that builds a fake
Micromate -- phase 1a's included -- failed with FileNotFoundError. Same
precedent as tests/fixtures/micromate-setup/: UM20147's own bench events.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- Series4Session's docstring now states which errors keep the line: an
op raises a DeviceError only for a verdict on a healthy link (not
found, stale, unnameable), and _exchange keeps the line for those; any
library error means the link is suspect and hangs up. DecodeMismatch
is a library error and hangs up -- conservative. Later ops must keep
to it.
- Test: a micromate TimeoutError mid-download, on a fresh DeviceAccess
(no retry path), is NoAnswer, closes the client once and leaves no held
line. It pins existing behaviour; a mutation that keeps the line on
library errors makes it fail.
- README, event rows corrected in place: another unit's id is 422 (not
409); a stale id is 409 without downloading, both series; an event
already stored -- including by THOR's watcher -- returns its row and
changes nothing (detail.already_stored); MiniMate lists give
record_type null, on the normal timeout, and fail on a lost reply.
No code behaviour change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
minimateplus's _extract_record_type returns "Waveform" for every 0C
record layout -- it cannot tell a histogram -- so a MiniMate histogram
was listed as "waveform". The fake's "Histogram" was a value the real
client never produces, which is why no test saw it.
- _s3_ref: record_type is always None, with
detail.record_type_note = "Series 3's event record does not say
waveform or histogram; not decoded yet".
- default_s3_events(): both events "Waveform", as the real client gives.
- The shared-shape contract test allows exactly {"record_type"} to be
None for Series 3 and nothing for Series 4.
Rows SFM stores for Series 3 still carry "Waveform" from the decode (the
same as the legacy blastware_file route); parked in the spec. No codec,
store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
One lost 1F reply made the list return 1 of 3 events as a 200, and on a
download gave a false 404. The list also ran on the 120 s download
timeout, so each lost reply stalled the walk 120 s with the unit locked.
- get_events() strict mode (headers_only, or only_key): a lost 0A reply,
a lost 1F(browse) reply on the success path and on the partial-record
path all re-raise their ProtocolError; a 1F that hands back a key
already walked raises ProtocolError("event chain did not advance ...").
Legacy calls (none of the new options) behave exactly as before --
pinned by tests of the same three faults under get_events().
- Series3Adapter.list_events runs on the default timeout (10 s on TCP);
download_event keeps 120 s.
- FakeProto gains optional lost-reply injection; its default is unchanged.
The repeat-key guard sits at the loop head, which is reached only for a
non-null key -- equivalent to checking each 1F's key, in one place.
Read-only; nothing new on the wire. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Series3Adapter.download_event compared the timestamp only after
download_event_by_key had run the whole 5A. A stale id cost a full
download of the wrong event (minutes on cellular), could surface the
64 KB-page 502 instead of 409, and a lost 0C reply was reported as "the
unit was erased".
- get_events() gains only_key_timestamp: with only_key, if the target's 0C
says another time (or none), the target takes the existing bypass --
no 1F(arm), no POLL, no 5A. A new branch only; it adds no command.
- download_event_by_key(key4, *, expected_timestamp=None) passes it on.
- The adapter converts the id's stamp to that ISO form and checks, in
order: no event -> 404; no readable 0C timestamp -> 502 MalformedReply
("could not read ... record (0C)"); a different time -> 409 StaleEvent;
no frames -> 502.
- The fake's download mirrors the real walk (no frames on a mismatch) and
records what it was asked for.
- Legacy get_events() (none of the new options) is pinned by a test of
its exact call sequence and 5A arguments, written before the change.
Read-only; nothing new on the wire. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Without Thor's TXT report, save_imported_idf fills only the three PPVs.
The unit's 0x0C record -- already read for the list and the stale check --
also gives the peak vector sum and the sensor location, and they were
dropped: Terra-View showed a blank PVS, and find_twins (which matches on
PVS) could not link the event to its histogram twin.
persist_download now overlays DownloadedEvent.record onto the bridged
event before insert_events, filling only fields the file left empty
(creating PeakValues / ProjectInfo when absent). Not the mic: its 0x0C
decode reads a denormal, parked.
The sidecar is written by save_imported_idf before the overlay, so it
still has no vector sum; the DB row does. No schema change, no migration.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
THOR's watcher (and Blastware's ACH) store every event through
/db/import/idf_file and /db/import/blastware_file, with the paired report.
Storing a download of the same event afterwards overwrote that richer copy:
on Series 4 the file, .h5 and sidecar were rewritten (extensions dropped);
on Series 3 the row lost PVS, project strings and ZC frequencies and was
repointed at a second, review-less file set.
persist_download now looks up (serial, timestamp) first. A row there is
returned as it stands -- inserted false, detail.already_stored true -- with
no store call, no insert_events and no sidecar write. Never merge.
- DownloadedEvent gains `timestamp` (the unit's own event time) and
`record` (Series 4's 0x0C fields); both adapters set them.
- The Series-3 `event is None` guard now runs before backfill/save, with a
message that is true there ("nothing was stored").
- Tests build the watcher's state exactly as the import endpoints do and
prove the row dict, the sidecar bytes and the file mtimes are unchanged.
No schema change, no migration, no codec change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
get_event() now delegates to fetch_event(), which returns (blob, result).
The same peak-vector-sum self-check applies, so a DecodeMismatch still stops
the bytes from being stored. get_event() keeps its signature and behaviour.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
list_event_headers() walks every event's 0A/1E/0C/1F without starting a 5A.
download_event_by_key() downloads one event in full and walks past the others
without their 5A, stopping once it has it. Both ride two new keyword options on
get_events() (headers_only, only_key); the default path is unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The /device guard let every non-UM serial through before its held-line
check. FastAPI drops an undeclared `serial`, so `?serial=BE18193` on a
legacy route still ran Series-3 code at an address holding a Series-4
line -- the hole the guard exists to close. Serial-aware routes go
straight to DeviceAccess, which refuses that case itself; everything
else is checked. baud is no longer parsed (it is not in the address
key, and pydantic's coercion made "38400.0" a second way past).
Also, from the same review:
- RingWatchTransport clears its frame state on every write, so a stray
STX on an idle line cannot hide the ring that answers the next request.
- Series4Session.is_open reads _client once; held_serial() calls it
without the unit lock, and a concurrent hang-up between two reads was
an AttributeError (a 500).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
0x06 content[0:4] moves from the bench tool into the client, tested against a real UM20147 read and its chain-walk count. read_unsolicited() reads without sending, for spotting RADIO RING on an idle session.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup:
record mode, sample rate, histogram interval, pre-trigger, stop mode, record
time, auto-stop, active sensors, trigger sources, the three geophone trigger
levels, mic type and (linear) mic trigger, job number, scaled distance, and
the four notes. MEASURED FIELDS ONLY -- everything graded inferred or
unknown in the reference stays in .raw.
micromate/setup_block.py holds the decode as pure functions (no I/O), plus
crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E. A failed checksum
raises SetupChecksumError (a ProtocolError) unless verify=False; a short
block raises either way.
Two things the decoder gets right that a naive one would not:
- the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6,
which hold the stored settings of whichever mic is NOT fitted;
- distance and charge weight convert back with the unit's own 3.2808 and
2.21, so 45 lb entered on the unit reads 45.0, not 44.89.
TESTS: 69 new. 15 real fixtures (2,103 B each) -- 14 UM20147 reads from the
10-17/10-19 keypad passes, chosen so every field takes at least two values,
plus UM12947's read from Thor's 9-24 capture (other firmware line).
Expected values are what the operator read off the unit's screen, never the
decoder's own output. Fixtures force-added, per the tests/fixtures/
convention. Full suite 541 passed; the 16 pre-existing failures
(test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged.
VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded
setup; against UM20147 every line matched the unit's screen (Brian, 10-19).
Also: the scratch harness uses the library checksum and checks all three
blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the
likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first
one this code has met").
No codec, store or DB change; no backfill.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The chunk-size ceiling, measured on UM20147 with every size checked
byte-for-byte against a known-good download:
1024 / 2048 / 4096 / 8192 / 16384 -> served in full
32768 / 65535 -> SILENTLY CLAMPED to 16384
The clamp is the important part: a 32,768 B request returns 16,384 B of perfectly
good data and no error. Nothing in the response says it was truncated; the
length is the only signal.
THAT DICTATES HOW THE LOOP MUST BE WRITTEN. read_event_file() now tracks its
offset by BYTES RECEIVED rather than striding by chunk index. A fixed stride
would either fail on a clamp or skip the bytes it never collected; tracking what
actually arrived makes a clamp cost one extra request, and makes the loop
self-correcting against any short response -- precisely the failure mode that has
bitten the Series III side repeatedly.
Consequence of that change, recorded because it reverses an earlier decision: a
short chunk is NO LONGER AN ERROR. It used to raise, on the principle that a
silently short event is this codebase's recurring bug. But the device returns
short legitimately, and the real protection is the offset arithmetic plus the
final total-length check -- which still raises on a genuinely truncated event.
The test was rewritten rather than deleted, and says why.
CHUNK_SIZE = 16384. For UM20147's events: 4,796 B goes 5 requests -> 1,
30,230 B goes 30 -> 2, and 72,560 B goes 71 -> 5. Over cellular at ~0.65 s per
round trip that is ~46 s -> ~3.2 s on the large one.
Measured on one unit over USB, so THOR_CHUNK_SIZE = 1024 stays available and the
replay tests pin it -- reproducing THOR's exact traffic is one argument away, and
client.download_event()/get_event() take chunk_size for a link where large
responses are not surviving.
Full suite: 472 passed, 16 pre-existing failures unchanged.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
UM20147's event 055d4a83 downloaded at exactly its promised size over USB,
exercising the carry into params[1] on chunks 64-70. The uint32 reading was
inference for one commit; it is now evidence, and the 64 KB cap that would have
made this event unfetchable is closed.
Worth noting what the same run prices: 71 chunks x ~0.65 s is roughly 46 SECONDS
for one 72 KB histogram over cellular, against 0.2 s over USB. That is the
round-trip cost model doing real work -- the bytes are nothing, the commands are
everything. A unit holding several events this size is a multi-minute call, so
the untested single-request offset_hi = 0x10 streaming mode (which would collapse
a download to one round trip) moves up the list.
Docstrings and the protocol reference downgraded from "inference" to "confirmed"
only where the hardware actually settled it.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
UM20147 holds a 72,560-byte event. chunk_params() wrote the offset as a uint16
at params[2:4], because every offset THOR was observed to send fits in two bytes
(largest 0x3400 = 13,312), which caps a download at 65,536 B -- so that event
could not have been fetched at all.
params[0:4] is demonstrably ONE 4-byte field: chunk 0 puts the 4-byte event key
there. Writing the offset as a uint32 BE in the same slot is BYTE-IDENTICAL for
every offset below 65,536, so nothing verified against THOR's 74 captured frames
changes -- the replay test still matches all of them -- and the range extends to
4 GB.
Above 64 KB this is inference and the docstring says so: the field's width is
established, the device's handling of a non-zero high byte is not.
Also newly reachable: at offset 1 MiB params[1] is 0x10, which must go out as
`10 10`. Nothing below 64 KB can produce that, so the uint32 change is what
first makes the case possible -- and an unescaped 0x10 in 5A params is the exact
bug that cost the Series III walk a release. Tested.
THIS IS THE SERIES III 64 KB PAGE-BOUNDARY BUG WEARING A DIFFERENT HAT. There,
parse_strt_end_offset() discards the key's page byte and the walk crashes once a
unit's buffer crosses 64 KB; that one is still open. The transferable lesson:
an address field whose high bytes are zero in every capture is not a narrow
field, it is an untested one. Same mistake, found twice, in code written years
apart.
Confirmed in the same run: 0x06 content[0:4] IS the event count -- UM20147 holds
5 events and reads 5, making it three for three across both firmware lines
(0->0, 6->6, 5->5). And content[4:8] is a CONSTANT, not a count: it reads 9 on
a unit with 6 events and on a unit with 5. list_events() still walks to the
sentinel; the count is worth adopting as a pre-check, not a replacement.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
Step 4 of docs/micromate_client_spec.md. MicromateEventRef plus list_events(),
iter_events(), download_event(), get_event() and decode_error(). 14 new tests;
112 micromate tests total.
The load-bearing test replays THOR's captured six-event download session through
iter_events() + get_event() and asserts EVERY BYTE WE EMIT MATCHES THOR'S, in
order -- 74 frames -- while decoding all six events and cross-checking each
waveform's peak vector sum against the float the device computed itself.
Two design decisions worth recording:
1. iter_events() EXISTS BECAUSE THOR INTERLEAVES. Its captured order is
0x93 -> 1E -> 0C -> 5A*n -> 0x93 -> 1F -> 0C -> 5A*n, downloading each event
before advancing the chain. list_events() walks to the end first, which is
fine for browsing but leaves the device cursor parked past the event a later
download addresses. 0x5A is key-addressed so it very probably does not care
-- but nothing observed says either way, so the interleaved path is the one
offered for downloads, and it is the one the replay test exercises.
2. get_event(verify=True) RECOMPUTES THE PEAK VECTOR SUM from the decoded
samples and compares it against the device's own 0x0C float. Two independent
computations over the same samples, so a disagreement means our decode is
wrong. Agreement on the bench events is 0.000%. Cheap insurance in a
codebase whose decode failures have historically been silent -- unhandled
block tags shorten a channel and nothing raises. It is a decode-correctness
check, NOT a truncation detector: a channel cut after its peak still yields
the right PVS, and the docstring says so. A test corrupts a stored peak to
prove the check actually fires.
MicromateEventRef.uid is SERIAL:key, because the key alone is ambiguous across
units, and .filename generates THOR's name (<serial>_<YYYYMMDDHHMMSS>.IDFW/H)
-- returning None rather than guessing when the record type is unknown, since
read_idf_file() dispatches on exactly that suffix.
Recorded as a CANDIDATE, not used: 0x06 content[0:4] looks like the EVENT COUNT
-- 6 on a unit holding 6 events, zeros on an empty one, and THOR reads it BEFORE
the walk then downloads exactly six events without ever reading the chain
sentinel. If it holds it lets a caller decide whether to walk at all, which
over cellular is the useful part. Two samples on one unit, and content[4:8]
reads 9 unexplained, so list_events() still walks to the sentinel: slower by one
round trip and correct on evidence rather than inference.
Full suite: 465 passed, 16 pre-existing failures unchanged.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
UM20147 captured over USB with mm_client_check.py --capture, read out with
scratch/mm_frame_parse.py: 11 frames each direction, 0 bad checksums. The two
BD-specific response data sections are now verbatim fixtures; only the frame
wrapper is rebuilt, which is sound because the framing is verified 251/251
elsewhere in the same file, and the reconstruction is pinned against the
payload length the parser reported.
Every field lands where the forward-offset model says it should:
data[0] = 0x30 = 48 = 59 - 11 (CB declares 0x2C = 44; the +4 holds)
content[1] = 0x0e monitoring
content[2:10] = 30 Sep 2026 14:00:49 matches the wall clock
content[34:36] = 3.50 V
content[36:44] = 15,000,000 total / 14,848,448 free
AND THE WARNING IS NOW DEMONSTRATED ON THE UNIT IT PREDICTED. Series III reads
battery from data[-10:-8], which on this block is e1 c0 -> 577.92 V. That is
the exact figure the A/B section named, and there is now a test asserting it,
so the reason the offsets are forward cannot be quietly refactored away.
Two corrections to the reference:
1. The four extra BD bytes are `0f a0 00 04`, not `0f a0 00 00`. Only the
first two look fixed. Nothing reads them, but the last is not padding.
2. POLL content[3] VARIES BETWEEN UNITS -- 0x50 on UM12947, 0x56 on UM20147.
It is printable in both cases ("P" and "V"), which is a second, independent
reason the POLL block cannot be parsed by scanning for printable runs: a
scan returns "PInstantel" on one unit and "VInstantel" on the other. The
fixed offset content[4] was the right call for a reason I had not seen.
The model string sits at content[26] on both firmware lines; only its tail
differs, so anchoring on "MM/" remains correct.
98 micromate tests pass. Full suite unchanged at 16 pre-existing failures.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
UM20147 read over USB by mm_client_check.py. The Thor firmware line was
entirely inference until now, and two of its three differences were covered
only by SYNTHESISED test frames. All three held:
- flags = 0x03 identifies the line -> reported firmware_line="thor". That is
only reachable if `10 03` in the flags position destuffs before indexing,
since 0x03 is ETX -- so the escaped-flags case is confirmed too.
- the model string is shorter -> reported "MM/ISEE/S" exactly. Anchoring the
search on b"MM/" rather than a fixed span is what made this work.
- the 0x1C block is 4 bytes longer with the extras TRAILING, so from-the-start
offsets survive -> battery 3.55 V and a clock correct to the second.
That last one is the one that mattered. Series III's from-the-end offsets
would have given this unit 577.92 V, which is why mm_client_check watches for
an impossible voltage: it is a free self-check on exactly the inference most
likely to be wrong.
Also clean: serial UM20147, 5 setups (factory.MMB -> test2.mmb), active setup
test2.mmb, 15,000,000 B total and free, 21 reads / 2,165 B in.
"One protocol stack drives the whole fleet regardless of firmware line" -- the
headline finding of 2026-09-23 -- is now demonstrated by a working client
rather than by matching response SUBs.
Test and docstring claims downgraded from inference to confirmed where the
hardware settled them, and left as synthesised-frame notes where it did not:
the BEHAVIOUR is confirmed but raw BD bytes are still not in the repo.
Added --capture DIR to mm_client_check: writes a raw_bw_*/raw_s3_* pair in the
layout scratch/mm_frame_parse.py already reads, so a run on an unfamiliar unit
becomes a test fixture without setting up a relay. Verified by round-tripping
its own output through that parser: 28 frames, 0 bad checksums.
Still not covered: a download from a BD unit (UM20147 had no events stored, so
the chunk walk remains CB-only), raw BD fixture bytes, a monitoring unit, a
nearly-full buffer, and the inbound call-home session.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
Step 3 of docs/micromate_client_spec.md: micromate/client.py, two models in
micromate/models.py, 26 offline tests. Every response constant in the tests
is a real captured data section from UM12947.
Field offsets were measured rather than taken from the spec, which turned up
one general rule and one trap:
THE RESPONSE SHAPE. Every response carries an 11-byte prefix and content
starts at data[11]. One rule, every command.
THE TRAP: data[0] is the content length & 0xFF, with no high byte anywhere in
the prefix. It is therefore correct for every response under 256 bytes --
most of them -- and then reports 44 for a 2,092-byte setup block, 30 for a
286-byte monitor-log record, and 0 for a 1,024-byte download chunk. 182 of
251 captured responses agree with a naive read; the 69 that disagree are
exactly the ones >= 256 bytes.
That is the third length in this protocol read too narrow, after
payload[9]-vs-payload[8:10] in the probe response. The client takes content
as data[11:] and lets the frame's own length bound it -- nothing needs the
declared length, since the frame already knows how long it is.
Also measured:
- POLL content[3] is 0x50, printable as "P", immediately before "Instantel".
A generic printable-run scan therefore returns "PInstantel" -- it caught a
test, not a unit. Vendor comes from a fixed offset; the model is found by
searching for "MM/", which is structural rather than positional and so
survives the Thor line's shorter "MM/ISEE/S".
- The setup walk terminates on an EMPTY NAME, not an error: 23 responses, 22
names, factory.MMB first through TEST1.mmb last.
- The 0x1C clock has an unidentified byte at content[6]; the hour is at
content[7]. The protocol reference's 0x1C section already had this right
and names the byte -- its one-line summary in the divergences list reads as
six contiguous fields and is the version not to trust. Re-verified against
three captures: 19:12:25, 19:13:34 and 01:14:05 against filenames stamped
19:12:14, 19:12:14 and 01:14:03.
- Battery and memory are read FORWARD from content start, never backward from
the end. This block is 4 bytes longer on the Thor line; the Series III
from-the-end offsets give a 11.0BD unit 577.92 V. A test appends the four
trailing bytes and asserts the forward offsets survive.
connect() is narrower than the spec asked. The spec said to mirror Thor's
POLL -> SERIAL -> 0x49 -> POLL "because it is known-good"; measurement showed
that is Thor's connection check (3 of 8 sessions) and its fourth frame repeats
its first. So connect() sends the three reads that gather something, and
0x01 is not read at all -- Thor never reads it, its layout is unmapped, and
firmware_line comes free from any response's flags byte. If a unit ever
refuses the next command after a cold connect, put the fourth POLL back and
record it.
A dead clock battery yields device_time=None rather than failing the whole
state read; an unreadable active setup yields active_setup=None rather than
failing connect. Both are real device states.
Still verified only against 11.0CB and only over USB. The BD offsets follow
from the extra bytes being trailing, which is documented but not something
this code has seen.
Full suite unchanged at 16 pre-existing failures; 445 passed, up 26.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
Step 2 of docs/micromate_client_spec.md: micromate/protocol.py plus 35
offline tests. Reads only; nothing here writes, erases or changes
monitoring state.
The tests replay Thor's captured responses through a scripted transport and
assert the bytes we emit are the bytes Thor emits -- including a full replay
of the six-event download session, all 56 0x5A frames byte-for-byte. A
passing test therefore means a real unit has already answered exactly that
frame.
Measuring the spec's command table against the captures found three more
errors in it, on top of the three the framing work found:
1. SUB 0x0A is the MONITOR-LOG WALK, not a keyed "event header, 30 B list
record" read. The same request repeated returns successive 297-byte
records -- serial, mode, thresholds -- until an 11-byte ack ends the
list. The device holds the cursor; nothing in the request selects a
record, and all nine captured frames carry identical params.
Structural divergence worth noting: Series III reaches the same data via
a record-type discriminator on its event chain, so partials and events
share one walk. Here the monitor log has its own cursor and the event
chain never sees it.
2. 0x1E/0x1F carry token 0xFE at params[7]. The protocol reference
documents all-zero params -- that was our own browse probing, which also
worked. Thor sends 0xFE on browse and download alike.
3. SUB 0x01 (device info) is never read by Thor in any captured session.
Its 0xFFFF offset comes from our own probes, so it is the one read in
the table with no Thor precedent. Flagged in the docstring.
Two useful negatives, both from absence rather than presence:
- No SESSION_RESET (41 03). Series III needs that 2-byte signal or a
monitoring unit will not answer POLL over TCP. Zero occurrences across
all 8 sessions, including 40 frames exchanged with a unit that WAS
monitoring.
- No universal preamble. The only invariant is that a session opens with
POLL; POLL -> SERIAL -> 0x49 -> POLL is Thor's connection check and
appears in 3 of 8 sessions. Setup pushes and scheduler reads open
differently.
Two deliberate divergences from the Series III sibling:
- strict_checksums defaults True and RAISES. minimateplus logs and
continues because its parser cannot always tell an inner-frame delimiter
from a checksum byte; that does not apply here, where the rule is exact
on 251/251 frames. The lenient default is instructive -- it hid a wrong
checksum rule for two days.
- read_event_file() raises ShortRead rather than returning a truncated
event. The expected length is known up front, so the check is free, and
a silently short event is the failure mode this codebase keeps hitting.
Every exchange resets the parser before sending, so a leftover frame is
discarded rather than answered with -- expected_sub catches a mismatched
SUB, but a same-SUB leftover would sail through with data for the wrong key.
File transfer (0x94/0x48) is deliberately out of scope: it needs a
data-carrying request frame, which is the frame type writes use, and that
boundary is worth keeping crisp in a read-only pass.
Full suite unchanged at 16 pre-existing failures (missing gitignored
fixtures); 419 passed, up 35.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
Step 1 of docs/micromate_client_spec.md: micromate/framing.py plus 31
offline tests. Every rule was checked against the captures BEFORE being
written, which is the only reason this commit is not a bug.
Three things the spec asserted are wrong, all of which fail silently:
1. Requests are NOT plain Series III frames. A Micromate escapes four
byte values -- 0x02 0x03 0x04 0x10 -- where Series III escapes one.
minimateplus.build_bw_frame reproduces 161 of Thor's 218 captured read
frames; build_request() reproduces 218/218. The 57 it missed include
EVERY 0x5A download (offset 0x0400 puts a literal 0x04 in offset_hi)
and the scheduler enable. An unescaped 0x03/0x04 terminates the frame,
so the unit never answers -- indistinguishable from a dead unit, and
event download would have hit it on the first request ever sent.
2. The checksum is plain SUM8 of the destuffed payload, not the DLE-aware
variant. 251/251 both directions. The DLE-aware form is correct
paired with Series III destuffing, which leaves an escaped byte as two
bytes; after uniform destuffing it subtracts the correction twice and
disagrees with the wire on 55 of 251 responses.
scratch/mm_frame_parse.py shipped with exactly that pairing and looked
clean only because it accepts either rule -- so it labelled those 55
"SUM8" and never flagged one bad. "Zero bad checksums" was true and
carried no information. A tool that tries N candidate rules cannot
falsify any of them. Fixed to validate against SUM8 alone.
3. SUB 0x5A is a 1024-byte chunk loop, not one request per event. Thor's
form, verified on all six bench events (4,076 -> 13,424 B): chunks =
ceil(size/1024), offset = min(1024, size - 1024*i) as a byte count,
params[2:4] = the byte offset, response data = offset + 11.
sum(offsets) == size exactly, every time.
This does not retract the earlier single-request observation -- that
used offset_hi = 0x10, which in Series III is the bulk-stream marker,
so it is plausibly a distinct streaming mode returning several frames.
Those captures never landed in the repo, so it cannot be re-derived.
Implement Thor's form; the other is worth one bench test.
Also: a 0x10 inside request params needs no special handling (settled --
Thor sends it, the wire doubles it), so the planned NotImplementedError
guard is gone. declared_length -> probe_length, because it is only
meaningful in a probe reply and Thor never probes.
Synthesised test frames are marked and each says what it stands in for.
The flags=0x03 case is the only coverage of the Thor firmware line -- it
wants a real 11.0BD capture next time UM20147 is on a bench.
No writes. Read-path framing only; nothing here can originate a command.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
Follow-up to the ts1→ts2 fix: get the trigger to the second from the binary
alone, instead of falling back to the stop time (~record-duration late) for
no-report events.
The configured post-trigger record time is a big-endian float32 in the
recording-setup config block, exactly 30 bytes before the "Standard Recording
Setup" marker. _parse_record_time_seconds reads it; the waveform branch now
stamps trigger = ts2 - record_time. Verified: the field reads 1.0 / 2.0 / 3.0 s
across different setups in the corpus, and all 7 BE12844 oracle events now
decode to their exact Blastware trigger (N844LQHB 10:33:29) from the binary,
no paired .TXT needed. Falls back to ts2 (the stop) if the config block is
absent. A paired report's event_datetime stays authoritative (clock drift).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
read_blastware_file built ev.timestamp from footer ts1, which for a WAVEFORM is
the monitoring-session start (a unit arming at 06:00 stamps 06:00 on every event
that day) — so every waveform's time was hours off (vomit-list #3, "~4.5 h off").
The event time is footer ts2 (the recording stop); BW's displayed Date/Time is
the trigger = ts2 - record duration.
Root cause proven against the BE12844 oracle set: 5 of 7 events decoded to the
identical 06:00:13 (the shared session start); ts2 gives distinct plausible
event times (N844LQHB ts2 = 10:33:32, BW trigger 10:33:29 = ts2 - 3.0 s rectime).
* read_blastware_file now uses ts2 for waveforms (discriminated by which codec
decoded the body, not the filename — save_imported_bw passes a tmp name).
Histograms keep ts1 (the ~24 h window start, which IS the event time).
* Binary-only decode can't get the exact trigger: the STRT record-time byte is
a misparsed record-type marker (0x46=70), so ts2 (the stop, ~record duration
after the trigger) is the best estimate. A paired BW report carries the exact
trigger — apply_report_to_event now overlays event.timestamp from
report.event_datetime, matching the existing build-path override (line ~441).
Tests: waveform → ts2, histogram → ts1 unchanged, report → exact trigger.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
Make the sensor self-check a first-class part of the standardized decoded event
so SFM stops decoding it at report time — device-agnostic, per the store's
decoder→standardized-.h5→SFM model.
* Event gains a `sensor_check` field; both decoders attach the traces where
they set raw_samples — series-3 in event_file_io.read_blastware_file
(minimateplus.sensor_check), series-4 in waveform_store's IDF path
(micromate.sensor_check). Covers ingest and backfill (both re-decode).
* event_hdf5 bumps schema_version 1→2 and writes an optional /sensor_check
group (raw counts, int32, per channel present). read_event_hdf5 returns
it; plot_json_from_hdf5 carries it as a top-level key. Old v1 files still
read cleanly (no group → None), so nothing breaks before the backfill.
* gather_report_data reads sensor_check_waveforms from the .h5 and drops the
report-time series-3 decode — the report no longer reaches into a decoder,
and a series-4 event now lights up the same strip automatically.
Stored as raw counts (a shape diagnostic, rendered fit-to-box): the per-series
count scale differs and a physical mic unit is ill-defined, so conversion would
add complexity for no display benefit — easy to add later if a numeric use
appears.
Tests: .h5 roundtrip + backward-compat + plot_json + real series-3 decode
attaches to the Event.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf