Both protocol references, the spec's bench section and CLAUDE.md record
the bench: every settings change acknowledged, read back and confirmed on
the unit's screen, both units restored byte for byte; the escaped-
checksum stray byte (fixed); a MiniMate's open setup menu writes its
whole-block copy back on Cancel or Save, losing a remote change; the
alarm write at channel +38; [26:28] re-set by the unit while monitoring;
the first Micromate setup push with the unit's CRC equal to SFM's; the
Micromate scheduler switch in none of the blocks SFM reads.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The Config tab by serial is now the unit's edit form, headed 'On the
unit <serial> -- read HH:MM' and built from the server's editable
fields. Preview runs a dry run and shows old -> new, notes and anything
that blocks the change; Send (confirm) sends exactly what was previewed,
with its revision, then shows what the unit now holds and re-reads it.
An edit after a preview disables Send until the next preview. The
by-host form loses its write button; the read stays. Logic in
device_routing.js (Node-tested), glue in sfm_webapp.js, no inline JS.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brian: use the actual unit limits, not what has been used in the past.
Trigger 0.005-10 in/s in 0.001 steps (capped by the range), record time
1-90 s (Micromate) or the MiniMate manual's 1 MB table by sample rate
(13 s in Histogram Combo), job number 1-9999. The read-back reports any
value a unit does not take.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
A scheduled start loads the setup it names, so a change to another
setup would be undone at the next start: read schedule.dat and refuse
that case. Configurable work-hours recording, without THOR's scheduler
or setup files, is the agreed next project.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brian's intent (UM6047's trigger, notes typos, the backup unit), the
flow, the first-version fields, and what is measured: Series 3's
compliance block has Series 4's 0x1A layout; a whole 1A read assembles
to the 2,090 bytes Blastware writes back (exact on both 10-26 writes);
Blastware writes 00 00 at [26:28] and a per-unit constant after the
block.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44