Unescape each 1A data frame, take data[11:], drop the one non-content
byte that starts every frame but the last: 2,090 bytes headed by
N = 2090, Series IV's 0x1A layout. Measured on BE9441's 10-26
recording (12 reads, both frame patterns); the read after each
Blastware write equals the image written. read_compliance_content is
strict (a missing frame raises) and unjudged (a monitoring unit's
device-info answer comes back for the caller to recognise).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Measured at the bench 2026-11-03 (BE9441): while monitoring, a MiniMate answers
the 0x2C call-home read with its DEVICE-INFO block ('Instantel', 'MiniMate Plus',
its serial) -- as it answers 1A -- and idle again, minutes later, the call-home
block. SFM writes back only a block it just read, so a monitoring MiniMate's
call-home cannot be changed; the change core already refused (byte 5 read as
'unknown(0x6E)', nothing sent), but said so cryptically.
- minimateplus.protocol.is_call_home_block(raw): the block starts with its own
length 0x7C and is N (or N + 2) bytes unescaped; the device-info block fails it.
- The Series-3 change raises UnitStateUnknown (409) with 'did not return its
call-home settings -- a MiniMate answers the call-home read with its
device-info block while monitoring; stop monitoring first ... nothing sent',
for a dry run too. call_home_state returns enabled = None with that reason.
- The page's callHomeRows shows the reason in place of 'Unknown (byte 5 = ...)'.
A blind write while monitoring stays untested on purpose.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
call_home_image returns the unescaped N + 2 image, but the send path handed it
to write_call_home_config, whose write_image unescapes again -- and unescaping
is not idempotent: a real 0x10 before 02/03/04 loses its 0x10. A call-in time
of 16:02-16:04 (hour 0x10) is exactly that. One such time made the send refuse
before the wire yet audited as 'sent, acknowledgement lost'; two made it send a
block shifted by two bytes from [101] (num_retries and the time fields wrong).
The Blastware-frame test could not see it: it checked the image builder, not
the bytes the protocol framed.
- MiniMateProtocol.write_call_home_image(image) frames a built image once
(0x7E, ack 0x81, 0x7F, ack 0x80), raising ImageRefused before any byte when
it is not a whole block; write_call_home_config (the legacy multi-field path)
is write_image once + that. Its stale 127-byte docstring is gone.
- MiniMateClient.write_call_home_image uses it.
- The Series-3 change passes is_refusal=ImageRefused, so a pre-wire refusal is
audited as nothing sent (sent = 0), not as a lost ack.
Tests drive the real client -> protocol over a stub answering with BE11529's
recorded acks: the unit's own read, a 16:02 time, and 16:03 + 16:04 all go out
exactly as built; a short image is refused with nothing written.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- minimateplus.protocol: call_home_enabled(raw) reads byte 5 of the UNESCAPED
0x2C payload (0x01 on / 0x00 off, measured 2026-04-20; anything else None --
bench finding #1's lesson: an escaped byte before it would move the raw
index); call_home_image(raw, enabled) is write_image's N + 2 image with byte 5
set and everything else as read, refusing a byte 5 never measured.
- MiniMateClient.read_call_home_raw() / write_call_home_image(image) (0x7E then
0x7F, each ack checked, never retried).
- Series3Adapter.call_home_state (wake, then 0x2C; no serial read, like status)
and change_call_home: the shared change core with a connect() identity check,
state 'enabled' / 'disabled' / 'unknown(0xNN)' (unknown sends nothing), the
plan showing both exact frames, a snapshot of both unescaped images.
- S3_CALL_HOME_FRAME_VERIFIED = False: a live change is refused (501) before any
connection until the frame is reproduced from Blastware's (next commit).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Measured against every Blastware request on record: the uploaded Feb-Apr 2026
captures (3,869 frames, 3,869 re-encode exactly) and BE9441's two sends on
2026-10-26 (26 write frames). A write is the standard 16-byte request plus its
data, every 02/03/04/10 escaped, SUM8 checksum; the length field is the data's
length. A config block starts with its own length N and is written as N + 2
bytes: event index (68) and trigger (82) as read plus 02 00 / 00 00 (constant on
15 sends), waveform data (69) and the 2,092-byte compliance image (71) whole.
The compliance image goes in addressed chunks (params[2:4] = address): 512 bytes
tonight (Blastware 10.74), 1,024 in March.
- framing.build_bw_write_frame: uniform escaping, SUM8, length = len(data).
RETRACTED: 'only BW_CMD doubled', the 'DLE-aware checksum', 'offset = data[1]
+ 2' -- fitted to frames still holding their escape bytes ('data 91, offset 90'
was 90 bytes and one escape). It got 7 of every 13 frames in a write wrong.
- protocol.write_image(): unescapes (callers may pass the parser's form), adds
the trailing two bytes to an N-byte block, and REFUSES anything else before a
byte is sent -- an edit beside a kept escape byte (the old encoder's anc-9
hazard) leaves an image one byte long.
- write_compliance_config_raw: 512-byte addressed chunks, then confirm 72.
- read_event_index / read_waveform_data_raw unescape before slicing (a block
holding 02/03/04/10 came out short); new read_trigger_config (SUB 0x2E).
- apply_config reads the unit's trigger block. RETRACTED: the block
'hardcoded from 3-11-26 -- no read exists'. Blastware reads it; byte 5 has
been 01 / 03 / 04 by unit and session, and the March copy (03) would have
changed BE9441's (01).
- The call-home write (7E) goes through write_image: its 127-byte 'read + 00 00'
is the 126-byte image (N = 0x7C). No Blastware 7E is on record here -- that
one is inferred from the other 77 write frames.
Tests: tonight's 26 and every Feb-Apr write frame rebuilt byte for byte; each
block as read written exactly as Blastware wrote it; the parser's form; the
stray-byte refusal; the reads against the unit's recorded replies; apply_config
writes BE9441's own trigger block. Six mutants, each caught. The old
test_write_frames.py (25 tests that had been skipping) runs now that the
captures are here, rewritten to the measured model.
Not yet sent to a unit: a config push changes settings, so its first live use
is a bench session with Brian. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Second start through SFM, BE9441 2026-10-26 23:54:41: acked 0x69, and Brian saw
'starting, performing sensor check, recording' -- but the read-back's single
SESSION_RESET + POLL went out 2.3 s after the ack, inside the ~30 s sensor
check, and was never answered or re-sent (504 after 120 s, audit ca7b5b42).
Brian: every unit is set to sensor-check before monitoring, ~30 s, then
'Recording...'.
- MiniMateProtocol.wake(attempt_s, deadline_s): SESSION_RESET + POLL re-sent
every attempt_s until the unit answers, then the POLL data step; a named
timeout at the deadline. Reads only. MiniMateClient.wake() wraps it.
- The Series-3 change: after a START, the first read waits S3_SENSOR_CHECK_S
(30 s) before asking; every read then wakes with retries (every 5 s, up to
60 s). A stop is unchanged -- its read-back was confirmed three times tonight.
Tests: a unit deaf for 4 probes is asked a 5th time and answers; a unit that
never answers ends in the named timeout after ~6 probes; a start's first read
waits the sensor check, a stop's does not; every read is preceded by a wake.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Follow-ups from the review of 887e75d (verdict: keep, with fixes; no critical).
- The cap: a caller's max_chunks (client.py passes 128) now bounds only a walk
whose end is unknown. With STRT it cut every event past ~66 KB short --
2,545 of 63,500 archived histograms are bigger (the review's count, DL2).
Strict raised; legacy sent a TERM for most of the event, or a bare ValueError.
- A STRT claiming less than one 0x200 chunk, or more than 4 MiB (a sanity bound,
not a measured limit), is refused as a misread, in both modes -- once a bare
ValueError and a 500.
- TERM is sent only for a true tail (< 0x200). After an early end the legacy
walk returns what arrived and sends none.
- build_5a_request wraps build_bw_frame; the old 5A helpers are marked
superseded (kept for tests/test_5a_protocol.py) and their imports dropped.
Tests: all 8 recorded events (were 4) walk exactly as Blastware and rebuild its
own files; an end key holding escaped bytes; a 300 KB event past a 128 cap; both
misread-STRT refusals; the 1A frames BE9441 answered post-fix; the checksum
vectors retargeted. Mutants the review saw survive (no STRT un-escape; a
standard-request escape revert) and 3 new ones are each caught.
Measured on the way: a reply's checksum is SUM8 of its unescaped payload,
748/748. The 'S3 checksums frequently fail' note was the parser summing its
own kept escape bytes; noted, parser unchanged.
Docs: the crossing count corrected to four (events 1, 3, 5, 7); the remaining
stale 5A sections in CLAUDE.md annotated; the write-frame suspicion recorded as
inferred only. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
A recording of Blastware downloading all 8 of BE9441's events (three crossing
a 64 KB page; tests/fixtures/minimate-bench-10-26-26-blastware/) settles it:
every one of its 748 requests is the standard 16-byte payload with a SUM8
checksum and every 02 / 03 / 04 / 10 byte DLE-escaped -- 748/748 re-encode
byte-identically. A 5A request is not a special frame: it is that payload with
a 2-byte LENGTH (0x0200 per chunk, the remainder for TERM) and a 4-byte linear
ADDRESS. The walk is the event's start, +0x200 at a time carrying into the page
byte, then TERM at the next boundary for exactly the remainder.
What the old model misread: the fixed 'offset 0x1002' is length 0x0200 escaped
(10 02 00); the first event's 'metadata pages at 0x1002/0x1004' are its chunks
at 0x0200 and 0x0400; the 16-bit counter could not leave the key's page.
- build_bw_frame escapes the four values (was 0x10 only); new s3_stuff().
- build_5a_request(address, length); parse_strt_end_key() -> the full 32 bits.
- read_bulk_waveform_stream: one linear walk, no event-1 special case; strict
mode keeps every refusal; an end at or before the start is refused as a
corrupt STRT (a page crossing is no longer refused -- it downloads).
Tests: all 540 Blastware 5A requests and all 208 others rebuilt byte for byte;
SFM's walks for events 0, 1, 3 and 7 send exactly Blastware's requests and,
fed Blastware's recorded replies, build whole events. In-page requests are
byte-identical to before. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Bench re-run 2026-10-26: BE9441 events 2 (0111c92c) and 19 (0118a4ca) end in
the next page, so STRT's 16-bit end offset reads lower than the start. The walk
then failed in bulk_waveform_term_v2 with a ValueError ('end_offset 0x2F06 must
be > last_chunk_counter 0xC92C') that the adapter's struct.error mapping did not
catch: a generic 500. Strict mode now refuses such an event by name right
after the probe -- 'crosses the unit's 64 KB page boundary ... the known 5A
page bug; not saved' -- before any chunk is sent. Not stored either way. The
page bug itself is unchanged (CLAUDE.md: needs a BW capture of a spanning event).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Review of d73a27d: _await_poll_or_boot no longer reset the parser and pending
frames the way _recv_one(reset_parser=True) did, so a reused protocol object
with half a frame left over failed startup (UnexpectedResponse A4 vs A5).
Restored. Also: the banner check now runs before the tail is trimmed (a read
carrying >48 bytes after the banner lost it), and a banner caught during the
200 ms drain is reported, so startup goes straight to the re-poll loop instead
of the full timeout. Tests for all three.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
BE9441 on a serial cable (bench, 2026-10-25) twice sent "Operating System"
~3 s after the port opened and ignored the POLL sent before it; the request
then failed at the full receive timeout (502 after 15 s on /device/info, 504
after 120 s on a download). After a mid-download reboot it answered 8.8 s
after its banner -- the one measured readiness point.
startup()'s first POLL now stops waiting the moment the banner arrives (that
POLL will never be answered) and polls again every 2 s for up to 20 s. Without
a banner nothing changes: a silent unit fails at the normal timeout, with no
re-polling. Only SESSION_RESET and POLL are sent, so this is safe in front of
the change path too.
No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
BE9441 rebooted mid-download at the bench (2026-10-25): the chunk at 0x7D06
got one stray byte and then silence, the 5A loop logged "unexpected end-of-
stream -- proceeding to TERM", the TERM got no reply either, and the short event
(17,920 / 17,920 / 17,408 of 21,504 samples) was stored as a success.
read_bulk_waveform_stream(strict=True) now raises on every early end: no STRT,
a metadata page or chunk with no reply, a mid-stream terminator, the chunk cap,
or no TERM reply. get_events passes it for the strict walks (headers_only,
only_key) and, in strict mode, re-raises a 5A error instead of logging
"metadata unavailable" and returning the event without frames. The legacy
full walk is unchanged, call for call (strict passed only when on).
Tests replay BE9441's recorded session through the real MiniMateClient: whole,
event 1 comes back in full; with the 5A stream quiet from chunk 40 while the
walk is still answered -- the bench's reboot -- it raises "ended early".
No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
test: add regression tests for v0.14.x SUB 5A protocol fixes
refactor(logging): change warning logs to debug for less verbosity in write_blastware_file
## v0.13.0 — 2026-05-01
### Fixed
- **SUB 5A bulk waveform stream — over-read bug for events ≥ 2 sec.**
`read_bulk_waveform_stream` was walking the chunk counter past the actual
end of the event, picking up post-event circular-buffer garbage that
corrupted reconstructed Blastware files for any waveform > ~1 sec. The
loop now extracts the event's `end_offset` from the STRT record at
`data[23:27]` of the probe response and stops the chunk walk when the next
counter would step past it. Verified against three BW MITM captures
(4-27-26 + 5-1-26): 2-sec event drops from 37 over-read chunks to 7
bounded chunks; 3-sec drops to 9; non-zero-start "event 2" drops to 9.
### Added
- `framing.bulk_waveform_term_v2(key4, end_offset, last_chunk_counter)` —
computes the corrected SUB 5A TERM frame's `(offset_word, params)` per the
formula confirmed across all 3 BW captures. Not yet wired into
`read_bulk_waveform_stream` (the legacy TERM is still used to preserve the
existing `blastware_file.write_blastware_file` frame-structure expectations);
available for the next iteration that switches to BW's 0x0200 chunk step.
- `framing.parse_strt_end_offset(a5_data)` — extracts the event-end pointer
from the STRT record in an A5 response payload.
- Added `CallHomeConfig` model to represent the Auto Call Home settings.
- Introduced methods in `MiniMateClient` for reading (`get_call_home_config`) and writing (`set_call_home_config`) the call home configuration.
- Updated `MiniMateProtocol` with new commands for call home operations (SUB 0x2C for read, SUB 0x7E for write, and SUB 0x7F for confirm).
- Created API endpoints for retrieving and updating call home settings in the server.
- Enhanced the web interface with a new "Call Home" tab for user interaction with call home settings.
- Implemented JavaScript functions for reading and writing call home configurations from the web app.
Add full decode pipeline for 0x2C partial records from the device's event
list, representing continuous monitoring intervals where no threshold was
crossed. These records appear interleaved with full triggered events in the
browse walk and were previously ignored.
minimateplus/models.py
- Add MonitorLogEntry dataclass: key, start_time, stop_time, serial,
geo_threshold_ips, raw_header, duration_seconds property
minimateplus/protocol.py
- read_waveform_header() now returns (data_rsp.data, length) — full payload
including the record-type byte at position 0 — instead of the sliced header.
Callers that need the old slice use raw_data[11:11+length] as before.
minimateplus/client.py
- Add _decode_0a_partial_header(): auto-detects 9-byte (sub_code=0x10) vs
10-byte (sub_code=0x03) timestamp format, handles 1-byte inter-timestamp
gap, extracts serial via BE anchor and geo threshold via Geo: anchor.
- Add get_monitor_log_entries(skip_keys=None): browse walk (1E → 0A → 1F),
decodes partial records, skips full records and already-seen keys.
minimateplus/__init__.py
- Export MonitorLogEntry
bridges/ach_server.py
- After get_events(), call get_monitor_log_entries(skip_keys=seen_keys) and
save new entries to monitor_log.json in the session directory.
- Add _monitor_log_entry_to_dict() helper.
- Include monitor log keys in downloaded_keys for state persistence.
CLAUDE.md / CHANGELOG.md
- Document 0x2C partial record layout (timestamp format, ASCII metadata
region, 1-byte gap edge case) confirmed from 4-11-26 MITM capture.
- Version bump to v0.10.0; update What's next.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- Introduced new SUBs for monitoring status, start, and stop commands in protocol.py.
- Implemented read_monitor_status, start_monitoring, and stop_monitoring methods in MiniMateProtocol class.
- Added new API endpoints for monitoring status retrieval and control in server.py.
- Enhanced the web application with a monitoring panel, including battery and memory status display.
- Created a new Python script to parse SUB 0x1C response frames for monitoring status.
- Documented the monitoring status response format and field locations in markdown and text files.
Two improvements to eliminate the ~2-min-per-event wait and unnecessary
full-event-list download when only one event is requested:
1. protocol.py: pass timeout=10.0 to _recv_one in the 5A chunk loop.
Device responds within ~1s per chunk; 10s gives a safe 10x buffer.
End-of-stream detection (raw_bytes=1) now fires in 10s instead of 120s,
cutting ~110s of dead wait per event.
2. client.py: add stop_after_index parameter to get_events(). When set,
iteration stops immediately after the target event is collected — no
further 0A/1E/0C/5A/1F cycles for events the caller doesn't need.
3. server.py: pass stop_after_index=index to both /device/event/{idx}
and /device/event/{idx}/waveform endpoints so a single-event request
only downloads that one event.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
When the device finishes streaming waveform data, it sends a single
partial byte (raw_bytes=1) rather than a complete A5 frame, then goes
silent for the full 120s timeout.
Observed: 35 chunks succeed, chunk 36 times out with raw_bytes=1 —
identical for both events in the test run.
Fix: on TimeoutError, if bytes_fed > 0 and we already have collected
frames, treat it as natural end-of-stream and break to the termination
step rather than propagating the exception. True transport failures
(raw_bytes=0, no prior frames) still raise.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Wraps each recv_one call in a try/except TimeoutError, logging:
- On timeout: chunk_num, counter, raw bytes_fed (distinguishes "device
silent" from "device sent unparseable bytes")
- On success: chunk_num, page_key, data_len, contains_Project flag
Parser is explicitly reset before each chunk recv so bytes_fed is
accurate per-chunk rather than cumulative. Helps identify exactly which
chunk fails and whether the device is responding at all.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Add read_bulk_waveform_stream() to MiniMateProtocol and wire it into
get_events() so each event gets authoritative client/operator/sensor_location
from the A5 frames recorded at event-time, not the current compliance config.
- framing.py: bulk_waveform_params() and bulk_waveform_term_params() helpers
(probe/chunk params and termination params for SUB 5A, confirmed from
1-2-26 BW TX capture)
- protocol.py: read_bulk_waveform_stream(key4, stop_after_metadata=True) —
probe + chunk loop (counter += 0x0400), early stop when b"Project:" found
(A5[7] of 9), then sends termination at offset=0x005A
- client.py: _decode_a5_metadata_into() needle-searches concatenated A5 frame
data for Project/Client/User Name/Seis Loc/Extended Notes; get_events() now
calls SUB 5A after each SUB 0C, overwriting project_info with event-time values
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Old key was (page_key, chunk_len) which would incorrectly drop a second
config section that has the same length as the first (e.g. current-config
vs event-time-config when settings haven't changed).
New key is the full chunk bytes — only truly byte-identical chunks are
dropped. Different data that happens to share page_key and length now
comes through correctly.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Two-step probe+fetch for SUB 08 (EVENT_INDEX), returning the raw 88-byte
(0x58) index block. SUB_EVENT_INDEX and DATA_LENGTHS[0x08]=0x58 were
already registered — this just wires the method that calls them.
Docstring notes the partially-decoded layout (event count at +3 as uint32 BE,
timestamps at +7) pending live device confirmation.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
BE11529 sometimes returns frame D with page_key=0x0000 (44 bytes),
identical to the frame B response, inflating cfg to ~1115 bytes and
mis-aligning all field offsets. Track (page_key, chunk_size) pairs
and drop any repeat before appending to the running config buffer.