Commit Graph
7 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 f7a02b1fee fix(idf): a Thor file's own settings, notes and time (#44, #45)
A Micromate event read without Thor's report (SFM's own downloads) came out
with sample rate, pre-trigger and record time 0, empty notes, and a
1970-01-01 time; every Micromate .h5, report or not, stored pre-trigger 0.

- The settings were found by the bytes be 80 00 00 00 00 -- a -0.25 s
  pre-trigger and Fixed stop mode, not a marker -- so any other pre-trigger
  left them unread.  The event's settings record is now found by its own
  signature 00 2a 04 00 00 (fields at the live 0x1A block's head offsets).
- The event time is read at settings record + 0x34, not two fixed offsets
  that miss a header shape.
- The four notes are read at 0x23c ([label 22][value 42] x 4).
- IdfEvent.to_minimateplus_event sets pretrig_samples.
- save_imported_idf fills the pre-trigger and notes from the file when the
  report lacks them.

Measured against Thor's own reports on 2,027 corpus files: sample rate and
notes 2,027 / 2,027; record time and pre-trigger 291 / 291 waveforms; event
time = filename on 2,384 / 2,384.  The issues' 20 UM12947 bench files now
store 4096 S/s, 4096 pre-trigger samples (1.0 s), 3 s and their notes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
2026-11-20 14:45:52 -05:00
serversdownandClaude Haiku 5.5 7ff527df07 feat(micromate): read the unit's run state and refresh its serial on demand
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:20:12 -04:00
serversdownandClaude Opus 5.5 b3aff4ed66 feat(micromate): get_setup() -- the setup block decoded, checksum-verified, and read off a real unit
MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup:
record mode, sample rate, histogram interval, pre-trigger, stop mode, record
time, auto-stop, active sensors, trigger sources, the three geophone trigger
levels, mic type and (linear) mic trigger, job number, scaled distance, and
the four notes.  MEASURED FIELDS ONLY -- everything graded inferred or
unknown in the reference stays in .raw.

micromate/setup_block.py holds the decode as pure functions (no I/O), plus
crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E.  A failed checksum
raises SetupChecksumError (a ProtocolError) unless verify=False; a short
block raises either way.

Two things the decoder gets right that a naive one would not:
- the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6,
  which hold the stored settings of whichever mic is NOT fitted;
- distance and charge weight convert back with the unit's own 3.2808 and
  2.21, so 45 lb entered on the unit reads 45.0, not 44.89.

TESTS: 69 new.  15 real fixtures (2,103 B each) -- 14 UM20147 reads from the
10-17/10-19 keypad passes, chosen so every field takes at least two values,
plus UM12947's read from Thor's 9-24 capture (other firmware line).
Expected values are what the operator read off the unit's screen, never the
decoder's own output.  Fixtures force-added, per the tests/fixtures/
convention.  Full suite 541 passed; the 16 pre-existing failures
(test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged.

VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded
setup; against UM20147 every line matched the unit's screen (Brian, 10-19).

Also: the scratch harness uses the library checksum and checks all three
blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the
likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first
one this code has met").

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-19 18:20:25 -04:00
serversdownandClaude Opus 5 d7d72cadf8 feat(micromate): the event chain -- walk, records, download, and a self-check
Step 4 of docs/micromate_client_spec.md.  MicromateEventRef plus list_events(),
iter_events(), download_event(), get_event() and decode_error().  14 new tests;
112 micromate tests total.

The load-bearing test replays THOR's captured six-event download session through
iter_events() + get_event() and asserts EVERY BYTE WE EMIT MATCHES THOR'S, in
order -- 74 frames -- while decoding all six events and cross-checking each
waveform's peak vector sum against the float the device computed itself.

Two design decisions worth recording:

1. iter_events() EXISTS BECAUSE THOR INTERLEAVES.  Its captured order is
   0x93 -> 1E -> 0C -> 5A*n -> 0x93 -> 1F -> 0C -> 5A*n, downloading each event
   before advancing the chain.  list_events() walks to the end first, which is
   fine for browsing but leaves the device cursor parked past the event a later
   download addresses.  0x5A is key-addressed so it very probably does not care
   -- but nothing observed says either way, so the interleaved path is the one
   offered for downloads, and it is the one the replay test exercises.

2. get_event(verify=True) RECOMPUTES THE PEAK VECTOR SUM from the decoded
   samples and compares it against the device's own 0x0C float.  Two independent
   computations over the same samples, so a disagreement means our decode is
   wrong.  Agreement on the bench events is 0.000%.  Cheap insurance in a
   codebase whose decode failures have historically been silent -- unhandled
   block tags shorten a channel and nothing raises.  It is a decode-correctness
   check, NOT a truncation detector: a channel cut after its peak still yields
   the right PVS, and the docstring says so.  A test corrupts a stored peak to
   prove the check actually fires.

MicromateEventRef.uid is SERIAL:key, because the key alone is ambiguous across
units, and .filename generates THOR's name (<serial>_<YYYYMMDDHHMMSS>.IDFW/H)
-- returning None rather than guessing when the record type is unknown, since
read_idf_file() dispatches on exactly that suffix.

Recorded as a CANDIDATE, not used: 0x06 content[0:4] looks like the EVENT COUNT
-- 6 on a unit holding 6 events, zeros on an empty one, and THOR reads it BEFORE
the walk then downloads exactly six events without ever reading the chain
sentinel.  If it holds it lets a caller decide whether to walk at all, which
over cellular is the useful part.  Two samples on one unit, and content[4:8]
reads 9 unexplained, so list_events() still walks to the sentinel: slower by one
round trip and correct on evidence rather than inference.

Full suite: 465 passed, 16 pre-existing failures unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-30 18:29:32 -04:00
serversdownandClaude Opus 5 f09b7dcaaf feat(micromate): client layer -- connect, state, setups; read-only
Step 3 of docs/micromate_client_spec.md: micromate/client.py, two models in
micromate/models.py, 26 offline tests.  Every response constant in the tests
is a real captured data section from UM12947.

Field offsets were measured rather than taken from the spec, which turned up
one general rule and one trap:

THE RESPONSE SHAPE.  Every response carries an 11-byte prefix and content
starts at data[11].  One rule, every command.

THE TRAP: data[0] is the content length & 0xFF, with no high byte anywhere in
the prefix.  It is therefore correct for every response under 256 bytes --
most of them -- and then reports 44 for a 2,092-byte setup block, 30 for a
286-byte monitor-log record, and 0 for a 1,024-byte download chunk.  182 of
251 captured responses agree with a naive read; the 69 that disagree are
exactly the ones >= 256 bytes.

That is the third length in this protocol read too narrow, after
payload[9]-vs-payload[8:10] in the probe response.  The client takes content
as data[11:] and lets the frame's own length bound it -- nothing needs the
declared length, since the frame already knows how long it is.

Also measured:

- POLL content[3] is 0x50, printable as "P", immediately before "Instantel".
  A generic printable-run scan therefore returns "PInstantel" -- it caught a
  test, not a unit.  Vendor comes from a fixed offset; the model is found by
  searching for "MM/", which is structural rather than positional and so
  survives the Thor line's shorter "MM/ISEE/S".
- The setup walk terminates on an EMPTY NAME, not an error: 23 responses, 22
  names, factory.MMB first through TEST1.mmb last.
- The 0x1C clock has an unidentified byte at content[6]; the hour is at
  content[7].  The protocol reference's 0x1C section already had this right
  and names the byte -- its one-line summary in the divergences list reads as
  six contiguous fields and is the version not to trust.  Re-verified against
  three captures: 19:12:25, 19:13:34 and 01:14:05 against filenames stamped
  19:12:14, 19:12:14 and 01:14:03.
- Battery and memory are read FORWARD from content start, never backward from
  the end.  This block is 4 bytes longer on the Thor line; the Series III
  from-the-end offsets give a 11.0BD unit 577.92 V.  A test appends the four
  trailing bytes and asserts the forward offsets survive.

connect() is narrower than the spec asked.  The spec said to mirror Thor's
POLL -> SERIAL -> 0x49 -> POLL "because it is known-good"; measurement showed
that is Thor's connection check (3 of 8 sessions) and its fourth frame repeats
its first.  So connect() sends the three reads that gather something, and
0x01 is not read at all -- Thor never reads it, its layout is unmapped, and
firmware_line comes free from any response's flags byte.  If a unit ever
refuses the next command after a cold connect, put the fourth POLL back and
record it.

A dead clock battery yields device_time=None rather than failing the whole
state read; an unreadable active setup yields active_setup=None rather than
failing connect.  Both are real device states.

Still verified only against 11.0CB and only over USB.  The BD offsets follow
from the extra bytes being trailing, which is documented but not something
this code has seen.

Full suite unchanged at 16 pre-existing failures; 445 passed, up 26.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-28 20:25:40 -04:00
serversdown 1ed86244d0 fix(thor-events): add parallel field for mic psi. Now shows mic in dbl and psi. (psi for charts) 2026-06-01 18:27:24 +00:00
serversdown ecc935482b seismo-relay v0.19.0 — device-family separation + micromate/ package
Tighten the Series III / Series IV boundary so UI and storage dispatch
on a clean signal instead of sniffing filenames or applying magnitude
heuristics.

Phase 1 — events.device_family column ("series3" | "series4"):
  self-applying migration with filename-based backfill of existing rows
  (1,132 backfilled on prod 2026-05-20); plumbed through every import
  path (BW endpoint, IDF endpoint, ACH server, BW CLI, sidecar
  backfill); UPSERT preserves via COALESCE; UI dispatches on it.

Phase 2 — extract micromate/ package alongside minimateplus/:
  native IdfEvent / IdfReport / IdfPeaks / IdfProjectInfo /
  IdfSensorCheck (mic in dB(L), not pseudo-psi); moved
  idf_ascii_report.py from sfm/ to micromate/; refactored
  save_imported_idf to use IdfEvent and bridge to minimateplus.Event at
  the SQL-insert boundary; idf_file.py stub for the future binary codec.

Phase 3 prep — docs/idf_protocol_reference.md captures the two
observed Thor binary header signatures (1,012 newer-firmware files vs
2 old files whose layout is byte-for-byte BW-STRT-compatible), file-size
hints suggesting int8 sample encoding, open questions in dependency
order, and a concrete first-session plan for cracking the codec.

Also rolled in the v0.18.1 hotfixes that motivated this work:
  - idf_ascii_report parser now handles "<0.005 in/s" (below-threshold)
    and "N/A" markers without leaving raw strings in numeric DB columns.
  - sfm_webapp.html: defensive _ppvFmt / mic formatter so future
    data-shape drift can't kill the whole events table render.

All 1,014 example-data sidecars round-trip through the new package.
See CHANGELOG.md for full notes.
2026-05-20 15:19:49 +00:00