K441LA17.IN0W's report says Units 'in/s and psi(L)' yet prints
MicTriggerLevel '125.0 dB(L)'. The value states its own unit, so that
is the one compared; the report's Units is the fallback. It was the
only MicTriggerLevel mismatch in DL2 (SFM's 0.005158 psi is 125.0 dB).