Files
seismo-relay/tests
serversdownandClaude Opus 5.5 9082236c5e fix(webapp): the final review's three page findings
- The arrow keys reached the legacy per-index waveform route in serial mode,
  even with no list loaded (an unlocked MiniMate chain walk + 5A on the same
  modem session).  perIndexLive() is now the one rule for the per-index
  buttons, the chips and the keyboard: live only for a list loaded without a
  serial that has events.
- A failed reconnect left the previous unit's confirmation live (badge,
  Diagnostics incl. the unguarded blind/slow-drip stops, call-home read).
  connectUnit() now drops it before it identifies; only this answer confirms.
- Unit strings reached innerHTML: the Device tab's cards (active_setup, new in
  1c) and its compliance/project tables now render as text, and Diagnostics'
  error spans go through escapeHtml().
- CLAUDE.md: the ring-path Runs A/B are a merge gate (the spec's prerequisite
  to a webapp sending serial), not only a use-time one.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 12:16:49 -04:00
..