Files
seismo-relay/micromate
serversdownandClaude Opus 5.5 55c7b7b5ae feat(codec): the MiniMate alarm level is writable (benched 2026-11-04)
S3_ALARM_WRITE_MEASURED = True.  At the bench on BE9441, with Brian's go,
the alarm went 1.0 -> 1.5 -> 1.0 in/s: each write acknowledged, read back
as sent, and shown in the unit's own setup menu.  The write moved exactly
channel +39 of the three geophone blocks (the f32 at +38), where the
event files put it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:12:58 -05:00
..