After its embedded event record, every Blastware event file carries the
unit's own per-channel summary: a chain of [length][id][payload] records,
ids 0x32 Tran .. 0x35 MicL, each with min, max, peak sample,
half-period and a displacement integral; the event record itself holds
the vector-sum peak's sample. Blastware prints these as they are
(measured on DL2, 2026-11-05):
- ZC frequency = (rate / 2) / half-period: 15,844 / 15,844 waveform and
104,000 / 104,000 histogram values; every word too (">100" at <= 5
samples, "N/A" at 0, "<1.0" beyond rate / 2). Recomputing from the
samples had reached 46%: the unit works at full resolution.
- peak displacement = half the integral x 16 counts x in/s per count /
rate: 19,479 / 19,479 (84% recomputed).
- times of peak and the vector-sum time now come from the unit's peak
samples. They equal the samples' argmax on 25,962 / 25,966 channels;
the 4 others are O117I1NK.R70W, whose stored samples wrap at the
trigger (Blastware's own sample table has the same wrapped values).
The event-record readers return the validated record's offset, so the
summary is read from that spot only. No summary: nothing is set, and
times of peak stay the samples'.
The checker reports ZC frequency and displacement, and reads the mic's
above-range flag under its real name (mic_zc_above_range).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9