- CLAUDE.md: a 1c entry under Where things stand (serial mode, what follows
the unit's own answer, writes off until phases 4-5, the Node-run page tests)
and the legacy-route guard in the REST API notes, with why the stop tools
are exempt.
- Spec: the 1c build status; the ring-path Runs A/B are still owed before
serial mode is used on a unit that calls home to THOR; which parked 1c items
the page settles (CORS: same origin; the S4 mic is not shown).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Review of b5037b0 (measured on 12 recorded SFM compliance reads): the read
keeps three escape bytes from its reply headers, so every real config image is
refused by write_image -- correctly, but only after 68 and 73 had been sent,
with a message saying nothing was. All four blocks are now checked first; the
test feeds the block exactly as SFM's read produces it and asserts no frame is
sent (two went out without the check).
Config push stays unusable on purpose: fixing that read alone would let the
compliance encoder write some fields to the wrong bytes (e.g. 4,096 sps as
4,112) while the image still passes. The rework -- logical read, encoding at
measured offsets with #48, a diff check, N pinned per SUB, an idle check, the
start/stop safeguards on POST /device/config -- is recorded in the spec and on
#46. Start/stop frames are unchanged (verified byte-identical by the review).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brian: stopping by command or keypad with ACH enabled makes the unit call home
and upload events + MLG, which can take minutes. Fits UM20147's 0x01 after a
stop (10-25). Owed: measure a MiniMate stop with ACH on, through the bridge.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Follow-ups from the review of 887e75d (verdict: keep, with fixes; no critical).
- The cap: a caller's max_chunks (client.py passes 128) now bounds only a walk
whose end is unknown. With STRT it cut every event past ~66 KB short --
2,545 of 63,500 archived histograms are bigger (the review's count, DL2).
Strict raised; legacy sent a TERM for most of the event, or a bare ValueError.
- A STRT claiming less than one 0x200 chunk, or more than 4 MiB (a sanity bound,
not a measured limit), is refused as a misread, in both modes -- once a bare
ValueError and a 500.
- TERM is sent only for a true tail (< 0x200). After an early end the legacy
walk returns what arrived and sends none.
- build_5a_request wraps build_bw_frame; the old 5A helpers are marked
superseded (kept for tests/test_5a_protocol.py) and their imports dropped.
Tests: all 8 recorded events (were 4) walk exactly as Blastware and rebuild its
own files; an end key holding escaped bytes; a 300 KB event past a 128 cap; both
misread-STRT refusals; the 1A frames BE9441 answered post-fix; the checksum
vectors retargeted. Mutants the review saw survive (no STRT un-escape; a
standard-request escape revert) and 3 new ones are each caught.
Measured on the way: a reply's checksum is SUM8 of its unescaped payload,
748/748. The 'S3 checksums frequently fail' note was the parser summing its
own kept escape bytes; noted, parser unchanged.
Docs: the crossing count corrected to four (events 1, 3, 5, 7); the remaining
stale 5A sections in CLAUDE.md annotated; the write-frame suspicion recorded as
inferred only. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
CLAUDE.md: the KNOWN BUG entry marked fixed (887e75d) with what settled it, and
retraction notes under the 5A sections that described the misreading (partial
stuffing, offset_hi 0x10 raw, 11-byte params, metadata pages 0x1002/0x1004).
Series-III reference: a 2026-10-26 (3) row. Spec: the MiniMate check updated.
Code comments that called the page bug open, updated; the adapter's struct.error
mapping kept as a defence, its message and test no longer naming the old bug.
Verified live on BE9441 the same day: all 8 events downloaded by serial, the 4
that cross a 64 KB page included, each whole and matching the unit's own peaks.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brian's Blastware downloads of BE9441's 20 events give ground truth. SFM's
re-run downloads of events 0, 1, 3, 4 and 10 are byte-identical to Blastware's
own files; imported first through the watcher route, the same events download
as already_stored (no duplicate rows -- the unit's 0C and Blastware's file agree
on serial + timestamp). Fixtures: Blastware's P00/Q10 (now asserted equal to
SFM's builds) and QZ0/T80, the two page-crossing events, as byte-exact targets.
The 64 KB page bug, narrowed by a read-only test walk: carrying the page byte
addresses the first chunk in page 0x12 (answered), but the next request carries
a raw 0x03 inside its params (counter 0x032c) and gets no reply. Pages after
0x11 have such counters; 0x11 does not (event 1 skips 0x0000-0x05FF). Needs a
Blastware wire capture of event 2 or 19 (recorded in CLAUDE.md, the Series-III
reference and the spec). No code change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Series-III reference: a 2026-10-26 row (5A checksum escape, measured), and the
2026-10-25 row's guessed cause of the mid-download reboot (battery, firmware)
retracted in place -- it was our request. CRLF kept. Spec: the re-run, item
by item, and what is still owed. CLAUDE.md: the phase-1b bullet brought up to
date.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Re-review of 64273c0: nothing pinned the TERM skip -- a TERM cut one byte off
loses a byte after the END record, invisible to every decode and peak check.
Golden sha256 of both fixtures' bodies and written files (event 0's file is
byte-identical to the one SFM stored at the bench before any fix; event 1's is
the bench's 25,810 bytes plus the 2 recovered), and a TERM moved to 0x1002.
The clipped-blast test now sits two steps past full scale (32032 counts), so it
needs the carve-out. Spec: the TOOL_VERSION reason corrected (no stored file
is affected); a MicL-only waveform is now refused -- failing safe, bench-check.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Series-III reference: the 0x15 serial is a C string (BE9441's "BE9441\x00?"),
A5 replies echo their address at data[2:6] (metadata pages only on the
event-1 walk), the unit boots on serial-port open (banner ~3 s, answered 8.8 s
after a reboot's banner), one mid-download reboot, and 24 index entries vs 20
listed events (inferred: monitor-log entries). Spec: the MiniMate check's
first run, item by item, and what is still owed. CLAUDE.md: the phase-1b
"unproven" line retracted in place, with the four bugs and the re-run owed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Bench, 2026-10-25, Brian's go per send: 0x96 acked in 464 ms and read back
monitoring at the first 2 s poll (during the sensor check); 0x97 acked in
116 ms, then 0x49 read a new value 0x01 for ~18 s (inferred: the unit's
call-home attempts after a stop) before idle; two stops to an idle unit acked
in 10 ms and changed nothing. Retracts "no command has ever been originated"
in place in CLAUDE.md and the reference's untested list; answers the spec's
stop-while-stopped question.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- New section "Left open by the phase 1b review (2026-10-21)", after the
1a one: twelve one-line items, each naming the phase it matters to
(retry re-running a whole download, last_used after a kept-line error,
verified:null's two meanings, mic naming + the S4 0x0C mic denormal,
500 detail text, the serial as a directory name, no server-level ring
test, S3 stored record_type, a fresh S4 download's gaps, orphan files,
same-second collisions, 423 Retry-After).
- The 1b bullets now give the owed MiniMate bench check's scope: a 3+
event list (1F(browse) after 1E(arm) without 1F(arm)), a non-first
event, a histogram (capture its 0C), an event past 64 KB (the named
502), a stale id (no 5A), and a dropped reply via mm_link-style fault
injection.
- The 1b "Download" bullet's "refreshes the row" is retracted in place:
the final review changed it to "returns the row, writes nothing".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Ten tasks, test-first: the is_open fix, two client reads, core types, the
per-unit lock, both adapters, Series-4 sessions with ring safety,
DeviceAccess with the reaper and the contract tests, the endpoints, and a
read-only bench check on UM20147.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Nothing breaks between phases: the shared models apply when a request names
the unit by serial, and the legacy Series-3 path stays as it is until the
webapp (1c) and watch_unit.sh move over.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brian's principle: talking to a Series 3 or a Series 4 unit is identical for
the user; only the serial prefix and each model's settings differ, and the
adapters absorb the rest.
Five places the draft broke it, now fixed: units are named the same way
(serial + address, no-serial kept only as a legacy Series-3 path); one set
of series-neutral response models with series-only fields under `detail`;
one opaque event_id for both; a uniform 501 "not supported for Series N
yet" instead of missing routes; and the webapp brought into scope with the
same screens for both. Adds an adapter table, contract tests that keep the
two adapters honest, and notes that existing Series-3 response shapes move
to the shared models (the webapp updates with them; Terra-View does not
call /device/*).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Parity of jobs with Series 3 for regular comms and settings (identify,
status, settings, events, download, monitor log, start/stop, call-home
enable/disable, setup push); Series-4 emergency tools deferred. A single
device-access layer: series from the serial prefix, identity confirmed
before any write, a per-unit lock, an 0xA2 opcode guard, read-back
verification of every change, distinct error codes, and an audit table.
Series-4 sessions ("stay on the line") now; Series-3 sessions after a bench
test of MiniMate hangup/DCD behaviour.
Includes the fix list found in the 2026-10-19 inventory, the to-be-added
table, and the RX55 container idea as a parking-lot item.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The wedged_unit_recovery runbook covered exactly one failure mode. BE12599
turned out to be a second one wearing the same symptoms, and the existing
procedure did not work on it.
Adds a "TWO failure modes" table up front so the next incident branches
correctly, and a full second-incident section covering what the ALEOS serial
debug log revealed: the device repeating a 29-byte AT modem-init string
(ATQ1/ATE0/ATS0=2, no ATD) every 75 s, never getting an OK because the modem
is in TCP data mode, and therefore never entering S3 mode at all. Inbound
cannot win against that, no matter how well framed.
Also records the two red herrings, since together they cost ~90 minutes:
the RV50 trusted-IP whitelist drops non-listed sources silently (presents as
a connect timeout, and Brian's dynamic dev IP had rotated off the list), and
sfm/server.py returns 502 for BOTH "Protocol error:" and "Connection error:",
so a 502 was misread as "TCP connected, device mute" and a theory built on it.
And the gotchas worth never re-deriving: slow_drip's send_error=null plus a
full duration is not success (only bytes_received > 0 is); stopping monitoring
removes the call-in trigger, so it costs you the channel; --events-only skips
the device-info step, so the serial is never read and ach_state keys on
peer:ephemeral_port, silently breaking dedup and re-downloading the same event
every session.
The plan doc captures the tool Brian wants built out of this — a rescue
listener with a real lifecycle and, critically, a confirmation gate before
shutdown, because leaving the modem's Destination pointed at a dead listener
is worse than never having started. Open questions are listed rather than
guessed at.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
7-task TDD plan: shape DSP module (crest factor + points-near-peak), shape_*
columns + auto-migrate, insert_events persistence, ingest population in the
save paths, backfill script, /db/events exposure + v0.24.0 bump. Phase B
(terra-view scoring/UI/review) gets its own plan once this feed is live.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf