serversdownandClaude Opus 5 f600fee965 feat(offset): the non-motion test, and BE12599 diagnosed as a connector
Brian noticed BE12599's 2026-08-09 event reports no ZC frequency because the
trace never crosses zero. That is the best detector in this investigation.

A geophone has no DC response, so its output must integrate to ~zero over a
record. |mean|/peak is therefore ~0 for real motion and ~1 for anything
electrical. Across 12,068 channel-events with peak >= 0.05 in/s the statistic
is bimodal with a 1.09% dead zone, and at mp >= 0.8 it returns exactly the five
confirmed units -- from physics rather than a tuned threshold. Two detectors on
different principles agreeing is the strongest corroboration the list has had.

It also settles BE11007 as NOT an offset: mp 0.75-0.89 but frac_neg 0.99 at
peaks of 7.4-9.4 in/s, i.e. a one-sided near-full-scale blast.

Journal 8e diagnoses BE12599 specifically. Its August waveforms are unipolar
impulses with an RC tail (26 ms -> 118 ms -> never recovers over 14 days), and
the fault MOVES between Long and Tran while the sensor self-check passes on
every event. A failing element cannot hop channels; a connector can -- which
also explains why the swing test never fails and why an autozero rarely helps.

Corrects 8c's claim that the spread gate is blind to onsets: of 87 BE18438|Vert
events it rejected one, the transitional record. Narrower than stated.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-09-07 19:01:28 +00:00
serversdownandClaude Opus 5 58c1fe8a96 docs(offset): mechanism campaign — five hypotheses dead, onset is a ramp
Records the mechanism investigation in journal 8c. The headline: still unknown,
but the shape is now constrained and a long list of dead ends is closed.

Onset is a ramp of minutes-to-hours, not a step — BE18438 Vert resolved to
one-minute cadence via the histogram corpus, 50% of the excursion in 7 minutes,
>=25 intermediates, validated 75/75 against Blastware's own ASCII. That kills
both poles of the original dichotomy: not a latched digital step, not slow
component wear. What survives is a reversible two-time-constant settling
process, which is a shape constraint and not a mechanism.

Thermal, ground-motion shock, handling/redeployment, accumulated duty, age,
firmware and a mechanical element fault are each refuted or explicitly bounded,
with the power behind every negative stated.

Retracts two claims this journal carried: polarity consistency was a tautology
of offset_scan3's spread gate, and the fleet is 8-9 units rather than 5 once
that gate is dropped. Also notes the gate is blind to onsets by construction --
it rejects a moving floor, and it rejected the one record where the ramp shows.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-09-06 09:33:12 +00:00
serversdownandClaude Opus 5 84bb53e185 docs(offset): relabel the four BlastMate units BA, not BE
BA9229, BA10060, BA10895 and BA15957 were reported throughout as BE — the
scanners synthesised the family prefix, which the BW filename does not carry.
Corrected across the journal with a note recording why, so the mistake is
legible rather than silently patched.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-09-06 08:00:48 +00:00
serversdownandClaude Opus 5 1daf693b32 feat(offset): scan the histogram corpus — the other 90% of the archive
offset_scan3.py covers only waveforms (6,577 unique binaries). The archive
also holds 63,535 unique histograms, which the pre-trigger method cannot
touch: a histogram carries no samples, only a per-interval per-channel peak.

scratch/offset_hist_scan.py scans them — 63,505/63,535 decoded (99.95%),
43 units, 77.9M intervals. It emits every candidate floor statistic per
(file, channel) rather than deciding anything, so thresholds get calibrated
against the waveform ground truth instead of guessed.

Journal §8b records the outcome. What survives is a site-quiet-gated
cross-channel differential that independently confirms BE18438|Vert and
BE9558|Tran+Long with a clean 2.5x separation gap and 0.037% day-level false
alarm, threshold-insensitive across a 2.3x span — the first operating point
in this investigation to pass that test cleanly.

What it does not do, recorded just as plainly: it finds 2 of the 5 confirmed
units, not 5. DC leakage into the interval peak is bimodal (0.9 on BE18438,
0.02 on BE12599), so a negative histogram result is not evidence of health.
Per-channel attribution is not established (channel-scramble p = 0.769) and
timing resolves to ~a month, not a day.

Two dead ends buried for good: the absolute floor is retired (66% of its
discrimination is a day/site confound), and zero-fraction is structurally
impossible — the device clamps every interval peak at >= 1 A/D count.

Two findings independent of the histograms:
- offset_scan3's spread<=0.02 gate discards 18.8% of rows with |pre|>=0.025,
  concentrated on 41 unit-channels currently labelled clean; 4 would be
  sustained positives without it. The fleet label is three-state, not two.
- The waveform corpus observes ~7% of the days a unit was deployed.

BE10895 is reclassified from transient to a genuine Vert fault of a different
subtype: 49.4% single-axis-dominant events, the highest in the fleet, all on
Vert. The other six marginal units are clean.

Not done: the 11 thin-coverage units were not screened, and no completeness
audit was run.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-09-05 02:08:36 +00:00
serversdownandClaude Opus 5 ad84a04404 feat(offset): detector v3 — pre-trigger floor with a constant-floor test
Brian's method, and better than v2's whole-record median: the pre-trigger
window is definitionally quiet (the buffer captured before the trigger fired),
whereas a median is merely robust to the event. Requiring the floor to hold
across pre-trigger / middle / end rejects transients that a median cannot.

    per channel:  pre/mid/end medians, spread = max - min
    offset when   |pre| >= floor AND spread <= 0.02 in/s
    real fault    >= 3 consecutive flagged events on that channel

The empirical noise floor justifies the threshold and validates the decoder:
across 19,244 non-flagged channel-events the pre-trigger floor is 62.7% exactly
0.000, 94.5% within +/-1 quantisation unit, median +0.0000, mean -0.0008. There
is no systematic zero-point bias — an independent confirmation of the
32000-count geo scale.

The result is threshold-insensitive across a 2x range (0.020 to 0.040 in/s),
which is what separates a real signal from a tuned one:

  FINAL: 5 of 45 units (11%) — BE9558, BE11529, BE12599, BE13117, BE18438

BE11007 and BE10895 drop out; the spread test identifies them as transients
rather than pedestals. v1's 11% headline was right by luck — it included
BE11007 and named the wrong channel on most units.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-28 21:18:33 +00:00
serversdownandClaude Opus 5 1fdc665675 fix(offset): retract the v1 detector — per-channel median, not dominant-axis mean
Brian challenged the v1 finding that offsets "come and go", against field
experience that a unit which develops one stays broken until the geophone is
replaced. He was right; v1 had two flaws, both of which manufactured false
recoveries:

1. It scored only the axis with the largest peak, so a real event on one axis
   hid a persistent pedestal on another. BE12599 on 2026-08-21 read "clean"
   because Long had a 1.065 in/s event, while Tran sat at +0.4732 in/s and was
   never examined.
2. It used the mean, which a real transient perturbs. The median is the resting
   baseline and a blast does not move it. Same event, Long channel:
   mean +0.0783 vs median -0.0050.

offset_scan2.py flags a CHANNEL when |median| >= 0.025 in/s (5 A/D counts,
Instantel's own criterion) and treats >=3 consecutive flagged events as the
real signal. No m/p ratio guard is needed — that existed only to compensate for
the mean.

Corrected results:
  units with any flagged event        6 -> 19 of 45
  units with a sustained pedestal     8 of 45 (18%)
  runs >=3 consecutive                29;  1-2 event runs (noise) 69

Also corrected: the affected channel is most often Vert, not Tran (v1 named
whichever axis had the largest peak, so it was frequently wrong). BE10895 and
BE18003 were invisible to v1. BE12599's fault began 2026-08-14, not 08-17.

The decode itself was never in question and is confirmed against Blastware's
own ASCII export: on K558LJN3.BK0W, BW shows Tran parked at +0.265..+0.375 in/s
for the entire record while Vert and Long sit at ~0.005 — Instantel's "parallel
lines above or below the zero line".

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-28 20:41:20 +00:00
serversdownandClaude Opus 5 5f1ee5ba91 docs: offset investigation journal; strip NUL corruption from CLAUDE.md
Adds docs/offset_investigation.md — a dated journal of the "offset" hardware
fault, in the style of the codec status docs: findings with provenance, dead
ends kept with the reason they died, and per-unit case files.

Contents:
  - base rate 5-6 of 45 units (11-13%) over the DL2 archive, 2018-2026,
    confirming rather than overturning the earlier 2-of-21 estimate
  - the detector, with the rationale for each term and its known blind spot
    (event traces carry real motion, so only trace-dominating offsets show)
  - the bimodality result: relaxing the amplitude floor 11x adds no new units
  - Instantel's own procedure and thresholds from their FAQs 13-0-21 / 12-0-10:
    A/D-mode ">5 counts", the autozero key sequence, and the 2027-2069 X1/X8
    acceptance window that explains the ~10% field success rate of a re-zero
  - four ruled-out hypotheses, each with the evidence that killed it:
    condensation, clipping, the sensor check as a predictor (102 offset events,
    zero failures — a grossly offset unit passes its own self-check), and the
    calibration-timing correlation (confounded, one unit per time bucket)
  - open questions, chiefly whether SUB 0x0E carries the autozero numbers

Cross-referenced from CLAUDE.md and Appendix E of the protocol reference
(whose CRLF line endings are preserved).

Separately: CLAUDE.md had 793 NUL bytes appended after its last line. They
predate this work (present at least as far back as e42956a / v0.21.0) and made
grep treat the file as binary, silently skipping it. Stripped.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-28 20:19:30 +00:00
serversdownandClaude Opus 5 306104354b feat(histogram): decode multi-interval blocks — recovers 415 files
Sub-minute histogram intervals are packed several to a block so that
every block still covers exactly one minute of data:

    interval   intervals/block   stride
    1 minute   1                 32     <- the standard big-endian block
    15 s       4                 92
    2 s        30                612

    stride = 12 + n * 20

Block = [00][segment][ctr uint16 LE][0a][00], then n x 20-byte records of
8 x uint16 LITTLE-endian values (T_peak, T_halfp, V_peak, V_halfp,
L_peak, L_halfp, M_peak, M_halfp) plus a 2-word tail whose first word is
0000 on every real interval, then a 6-byte block trailer.

The standard 32-byte block is BIG-endian; this variant is LITTLE-endian.

The tail-word check matters: a session ending mid-block leaves buffer
garbage in the remaining interval slots, which decoded as peaks
thousands of times the real value.  Stride detection also requires at
least 2 records, since a 1-record block would have stride 32 and
collide with the standard block.

Recovers 415 files that decoded to nothing: 216 on BE18193 (2 s
intervals) and 199 on BE9440 (15 s).  Before decoding to nothing they
were being accepted by the WAVEFORM codec, which returned garbage
peaking up to 400x the device-reported PPV.

Ground truth BE9440/K440L3AQ.T70H (5,710 intervals) matches its
Blastware ASCII export exactly: 17,130/17,130 geo peaks, 22,840/22,840
frequencies, 5,710/5,710 mic dB(L).  Across all 455 affected files,
1,354/1,365 channel peaks (99.2%) match the device-reported PPV; the 11
that don't are under-reads on BE9440 where the walk stops early.

Fixture (binary + ASCII) saved under tests/fixtures/, which is
gitignored per repo practice — the ground-truth test skips when absent.

Tests: 258 passed, failure list unchanged from baseline.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-26 04:59:00 +00:00
serversdownandClaude Opus 5 4c58a532de fix(backfill): remove stale .h5 when nothing decodes; log the 415-file histogram variant
backfill_sidecars.py skipped the .h5 write when a file produced no
samples, with the stated intent of not replacing it with an empty
placeholder.  That silently preserved output from a superseded decoder.

After the record-chain fix, 415 histogram files stopped decoding (216 on
BE18193, 199 on BE9440) but kept .h5 files whose peaks ran up to 400x
the device-reported PPV.  Those were feeding charts and the
false-trigger detector with nothing marking them.  The .h5 is now
removed in that case and the run reports stale_h5_removed.

Store-wide effect, series-3, decoded peak vs device-reported PPV:
  waveform   1307/1307 (100%), mean abs ratio error 0.00000
  histogram  4434/4435 (100%)
Both were 99% with a tail of 18 and 25 wrong files respectively.

The 415 files are a genuine unmapped format variant, not a regression:
their bodies open `00 00 00 01 0a 00` (valid block header, marker 0a at
[4], block_ctr 256) but block[28:32] matches neither known tail, and no
stride from 8 to 64 bytes places a marker at [4] consistently.  Bodies
are very large (one is 360,573 bytes).  They were previously being
decoded by the WAVEFORM codec, which accepted them and returned garbage
- so the gap pre-dates today's work; the fix only exposed it.  Logged as
an open question in the protocol reference.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-25 22:23:10 +00:00
serversdownandClaude Opus 5 9bb95003e9 fix(codec): the waveform body is a record chain, not a tag stream
Supersedes the segment-header model entirely, including the fixes made
earlier today.  Found via multi-agent structural analysis of the 25 files
that stalled the walker, then verified independently.

Records are self-delimiting: off+2 is a uint16 BE length, next_record =
off + 2 + len, and the chain ends on a record whose chan_id is 0x06.
off+8 carries a 3-valued mode enum:
  02 00  14-byte header, 2 anchors, then CUMULATIVE delta blocks
  01 00  10-byte header, no anchors, blocks are ABSOLUTE values
  00 03  10-byte header, NO TAGS AT ALL - raw 12-bit packed absolute

`40 NN` is an ordinary int16 BE data block (2*NN + 2), never a header.
Reading it as a 2*NN + 16 header is what made walks drift — the
"variable-prefix segment descriptors" reported earlier today were not a
format feature, just walker drift of exactly
4 - (old_stop - true_record_start), on all 25 affected files.

Measured on the production snapshot:
  all four channels equal length   156/1388 -> 1388/1388
  ASCII sample-count exact           72/75  ->   75/75
  ASCII fully exact                  70/75  ->   73/75
  device PPV waveform (live)       1288/1306 -> 1306/1306  (mean err 0.00000)
  device PPV histogram (live)      4434/4459 -> 4458/4459

Also eliminates the walker-over-read class: 24 of those 35 files were
histograms that read_blastware_file fed to the waveform codec first; the
old walker accepted them and returned garbage (one yielded 98,923
"intervals"), while the record-chain decoder returns None so they fall
through to histogram_codec.

00 03 records are DECODED, not skipped.  Skipping them silently shifts
the time base of everything after them on that channel — BE9558/
K558LOF2.820W had MicL displaced by exactly 512 samples with nothing
marking the gap.

Footer detection now prefers the 0e 08 candidate whose body yields a
chain terminating on 0x06; the signature can occur inside a sample
stream.  Blast radius 1 file of 1388.

The superseded model survives as decode_waveform_legacy, pinned by
micromate/idf_file.py: its Thor IDFW body-offset search trial-decodes
candidates and keeps whichever yields the most samples, so the new
decoder returning None where the old returned garbage changes that
heuristic's winner.  Deferred until that search uses the record chain.

Tests: 253 passed (+11), failure list unchanged from baseline.  The 9
tests pinning the superseded model are retargeted at
decode_waveform_legacy, which still implements it.

NOTE: stored .h5 files need regenerating — nearly all get longer.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-25 22:13:29 +00:00
serversdownandClaude Opus 5 ef1e99b0a0 fix(histogram): block is big-endian + terminal block tail — 1/1196 to 1211/1211
Two errors in the series-3 histogram block model, both found by diffing
against the per-interval data table in the preserved Blastware ASCII
exports (1211 files in the prod snapshot — far stronger ground truth
than the header PPV used previously).

1. The block is uniformly BIG-ENDIAN.  Peaks and half-periods are uint16
   BE (T_peak [5:7], T_halfperiod [7:9], V_peak [9:11], V_halfperiod
   [11:13], L_peak [13:15], L_halfperiod [15:17], M_peak [17:19],
   M_halfperiod [19:21]); only block_ctr [2:4] is little-endian.

   The old uint8-peak model silently CLIPPED any peak above 1.275 in/s:
   the final interval of BE18193/T193LQ9K.OE0H reads 8.270 in/s in BW's
   export (1654 counts = 0x0676) and decoded as 0x76 = 118 = 0.590.

   The byte documented as a per-channel "annotation" was never an
   annotation — it is the half-period's high byte, which is exactly why
   it was non-zero on the sub-Hz intervals BW renders as "<1.0".

   The marker is block[4] alone.  Testing [4:6] as a uint16 LE marker
   forced block[5] == 0, which is what capped the peak at one byte.

2. The final block of each stream carries tail 9c 06 00 42 instead of
   1e 0a 00 00, and holds arbitrary bytes at [21:23].  Rejecting it
   dropped the last interval of nearly every histogram — frequently the
   interval holding the event peak, so the file's PPV read low.

Verified end to end through the production path: 1211/1211 histograms
decode exactly (interval count + every per-interval peak), plus 842,442
per-interval frequency comparisons with zero mismatches.  Previously
1 of 1196 files was fully correct.

decode_histogram_body_full records expose `is_terminal` in place of the
removed `annotations` tuple.  +6 tests.  No regressions: full-suite
failure list unchanged from baseline.

NOTE: stored histogram .h5 files need regenerating to pick this up.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-25 18:59:25 +00:00
serversdownandClaude Opus 5 e449ac04af docs: sharpen the series-3 histogram open item — dropped intervals, not wrong values
Re-measured properly.  The first pass compared h5 max against the ASCII
header PPV and reported "26% of channels miss the peak".  The histogram
ASCII actually carries a full per-interval data table (Tran/Vert/Long
peak + freq + PVS per interval), which is real ground truth, so the
comparison should have been per-interval from the start.

Per-interval result, n=1196 series-3 histograms:
  - decoded VALUES are right: 1031/1196 (86%) match within 1 LSB across
    the overlapping prefix
  - the interval COUNT is short in 1195 of 1196 files: median 1 missing,
    1088 short by 1-2, 65 by 3-10, 39 by 11-100, 3 by >100 (max 205)
  - decoded max falls below the device PPV in 169/1196 files (14%), not
    26% — that happens when a dropped interval held the peak

So it is a termination bug in histogram_codec.decode_histogram_body,
the same family as the waveform-walker truncation fixed earlier today,
rather than mis-decoded interval values.  Series-3 only; there is no
preserved series-4 ASCII in the snapshot to compare against.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-25 16:23:51 +00:00
serversdownandClaude Opus 5 4f8224a751 docs(appendix-e): offset fault is geophone-side — operator swap test + MicL evidence
Operator report: attaching a different geophone to an affected unit
makes the offset go away.  That rules out the unit's analog front-end
and any stored per-channel zero constant (a constant lives in the unit
and would survive a sensor swap).

The stored data agrees — MicL, a separate transducer on its own cable,
shows no offset during either episode (|mean|/peak 0.17 and 0.02) while
the geo channels on the same unit at the same moment are pinned.

Two distinct sensor-side patterns recorded:
  BE18438  Vert 0.97, Tran 0.16, Long 0.18  -> one conductor pair
  BE9558   Long 0.99, Tran 0.90, Vert 0.81  -> shared return / ground

Candidate mechanisms narrowed to three, since a geophone coil is passive
and cannot generate sustained DC: galvanic corrosion at a connector or
splice (matches the ~46 mV referred to the ADC input), a leakage path to
shield, or changed coil DC resistance interacting with the amplifier's
input bias current.

Also records the confound: swapping a sensor requires a monitoring
restart, and these units run Sensor Check "Before monitoring", so the
restart re-zeros too.  The swap does not cleanly separate "new sensor"
from "the restart re-zeroed it".  Controls and the single best
measurement (open-circuit DC across the suspect connector) documented.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-25 15:06:34 +00:00
serversdownandClaude Opus 5 5d3963b545 docs: record the 2026-08-25 body-codec and geo-scale findings
Brings the protocol reference, CLAUDE.md and the codec RE status doc up
to date with everything confirmed in this pass.

instantel_protocol_reference.md
  - Changelog row for the five findings.
  - S7.6.1: scope table showing the 32000 scale correction applies to
    series-3 waveform, series-3 histogram and series-4 Thor alike, with
    the measured before/after ratios for each.
  - S15: closed "Full channel ID mapping in SUB 5A stream" — resolved by
    the segment-header channel id ([channel][00][00][segment], 0x46=Tran
    0x47=Vert 0x48=Long 0x49=MicL, 1697/1697 verified).  Four new open
    questions: variable-prefix segment descriptors, the histogram codec
    missing peak intervals (26% of channels), UM-series IDF decoding
    ~1000x low, and the Thor per-count LSB residual.
  - NEW Appendix E — Known Device Faults.  Documents the field-observed
    "offset" fault: symptom, why it floods the ACH queue (pedestal
    exceeds the unit's own geo trigger level), the episode table, the
    detection rule that works, what the data rules out (not the
    geophone, not the battery, not environmental, not condensation),
    and the two remaining candidate mechanisms with the test that
    separates them.  Explicitly flags that it is NOT a decode artifact,
    since that mistake has already been made once.

CLAUDE.md
  - Body-codec section: the four framing cases and the channel-id
    finding, with the corpus result.
  - "What's NOT solved": replaced the stale walker-edge-cases bullet
    with the four genuinely open items.

waveform_codec_re_status.md
  - Scale scope table matching the protocol reference.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-25 14:25:26 +00:00
serversdownandClaude Opus 5 686ab6e7a6 fix(codec): geo full scale is 32000 counts; 4 walker framing cases; channel-id from header
Two independent bugs, both found by diffing 75 production events against
their preserved Blastware ASCII exports (<store>/<serial>/<file>_ASCII.TXT).

1. Geo full scale was wrong — every geophone reading was 2.34% low.
   The codec emits geo samples in 16-count units with a documented LSB of
   exactly 0.005 in/s, and decoded_to_adc_counts multiplies by 16, so one
   ADC count is 0.005/16 in/s and 10.000 in/s is 10.0/(0.005/16) = 32000
   counts.  sfm/event_hdf5.py and minimateplus/event_file_io.py both
   divided by 32768 (2^15), scaling every sample and derived peak down by
   1 - 32000/32768.  The error scales with amplitude, so it was invisible
   on quiet events and worst on the loud ones that matter for compliance.
   Mic is unaffected (it back-solves its scale from the device peak).

   216 per-channel comparisons: 32768 -> 151/216 exact, worst error 0.238
   in/s on a 10 in/s event; 32000 -> 216/216 exact, worst 0.005 = 1 LSB.

2. walk_body silently truncated channels on four unhandled framing cases.
   An unrecognised tag ends the walk and decode_waveform_v2 returns
   whatever it got, so this surfaced as short channels, never an error:
     - wide-NN RLE `0X NN` (runs longer than 252 samples)
     - `30 NN` with NN > 0x10 (the old cap was arbitrary)
     - variable-width `40 NN` headers: NN counts previous-channel
       continuation deltas, so the header is 2*NN + 16 bytes; `40 01`
       and `40 03` occur alongside `40 02`
     - tagless segment headers: no `40 NN` tag at all, just the 14-byte
       tail [field2:2][len:2][channel_id:4][marker:2][anchors:4]

Also: the header field documented as a "monotonic uint32 LE counter" is
really [channel_id][00][00][segment_index], with 0x46=Tran 0x47=Vert
0x48=Long 0x49=MicL — verified on 1697/1697 segment headers, zero
disagreements.  decode_waveform_v2 now takes the channel from that field
instead of rotation position, which was fragile: one missed header
desynced every channel after it.

parse_segment_header now returns n_prev_deltas/prev_deltas/marker/
anchors/channel/segment_index; the old fixed_pattern (02 00 00 01)
conflated the 2-byte marker with the first anchor.

Ground-truth corpus, end to end through the production path:
  exact 37 -> 72, truncated 23 -> 3, full-length value errors 15 -> 0.
Store-wide, 729 of 1388 series-3 waveform events decode differently and
728 gain samples; the scale fix changes float values on all of them, so
stored .h5 files need regenerating.

Still open: 3 events truncate at a header variant with a variable-width
prefix (2/4/6 bytes) before the channel id and an `01 00` marker.
Documented in docs/instantel_protocol_reference.md with byte offsets.

+20 tests.  No regressions: the byte-exact fixture suite still passes and
the full-suite failure list is unchanged from baseline (16 pre-existing
failures from gitignored fixtures).

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
2026-08-25 08:11:11 +00:00
serversdown 23e4f585a8 fix(db): keep reviewed_real out of the Migration-1 rebuild table (positional SELECT *); regression test 2026-08-25 00:31:39 +00:00
serversdownandClaude Opus 4.8 5247e78669 docs(plan): B2-A — reviewed_real + 3-state mirror + twin review-propagation
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-08-25 00:25:02 +00:00
serversdownandClaude Opus 4.8 eb92b13aac docs(plan): waveform-shape FT detection — Phase A (seismo-relay)
7-task TDD plan: shape DSP module (crest factor + points-near-peak), shape_*
columns + auto-migrate, insert_events persistence, ingest population in the
save paths, backfill script, /db/events exposure + v0.24.0 bump. Phase B
(terra-view scoring/UI/review) gets its own plan once this feed is live.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-08-21 21:32:59 +00:00
serversdown 9b71ead44b series 4 codec work, inital decode success 2026-05-29 06:33:13 +00:00
serversdownandClaude Opus 4.7 d506ebc103 histogram_codec: peak count is uint8 (not uint16 LE) — properly cracks
the BE9558 / BE18003 extension-byte case

The bytes at [7]/[11]/[15]/[19] are an annotation field (purpose still
unclear — empirically non-zero on intervals with sub-Hz or unmeasurable
freq), NOT the high byte of the peak count.  The N844 fixture corpus
the original RE was done against had zero values in those bytes for
every block, so uint8 and uint16 LE were equivalent there — but on
real BE9558 Tran-drift events and BE18003 Histogram+Continuous events
the uint16 LE interpretation produced peaks up to 268 in/s and 35×
inflated PVS sums.

Cross-correlated against BW's per-interval ASCII export on:
  - K558LKZU/LL1P/LL3K  → 100% T/V/L/M peak match (1435 blocks each)
  - T003LKZR/LL0O/LL1M  → 100% T/V/L, 99.3% M (0.05 dB rounding only)
  - N599LKZS/LL0L        → 100% all channels
  - N844 fixture corpus  → 100% all channels (unchanged)

Annotations preserved on every record for future RE; the defensive
_MAX_PEAK_COUNT bound is no longer needed (uint8 maxes at 1.275 in/s,
well below any physical limit).

Synthetic regression test added using the verbatim K558LKZU.RE0H
interval-12 block.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-21 06:05:19 +00:00
serversdownandClaude Opus 4.7 7183b953e4 minimateplus: histogram body codec — FULLY DECODED
The histogram-mode event body is now byte-exact decodable.
Companion to the waveform body codec — together they cover every
event file the watcher forwards.  Cracked in one session via
cross-event correlation against BW's ASCII export.

The §7.6.2 spec in instantel_protocol_reference.md was structurally
correct (32-byte blocks) but the per-sample semantics were
under-documented.  Cross-checking block 130 of N844L6Z8.ZR0H
against its TXT row revealed the layout perfectly:

  slot[0] = 10 (constant marker)
  slot[1] = T_peak_count    (× 0.005 → in/s at Normal range)
  slot[2] = T_halfperiod    (freq_Hz = 512 / halfp)
  slot[3] = V_peak_count
  slot[4] = V_halfperiod
  slot[5] = L_peak_count
  slot[6] = L_halfperiod
  slot[7] = MicL_peak_count (dB via waveform_codec.mic_count_to_db)
  slot[8] = MicL_halfperiod

The `>100 Hz` sentinel is halfperiod ≤ 5 (since 512/5 = 100 Hz).
Mic dB uses the SAME formula as the waveform codec (sign × (81.94
+ 20·log10(|count|))) — they share the mic ADC calibration constant.

Block identification anchor: bytes [22:24] == 0x0000 AND
bytes [28:32] == 1e 0a 00 00.  The tail signature is the most
reliable distinguisher from non-block content in the file.

Files:

  minimateplus/histogram_codec.py (new) — decoder + public API
    matching the waveform codec's shape:
      walk_body(body) -> records
      decode_histogram_body(body) -> {Tran, Vert, Long, MicL}
      decode_histogram_body_full(body) -> [per-interval dicts]
      half_period_to_hz, geo_count_to_ins helpers

  minimateplus/event_file_io.py (modified) — read_blastware_file
    now tries the waveform codec first, falls back to the histogram
    codec on failure.  Same output shape, same downstream pipeline.

  tests/test_histogram_codec.py (new) — 24 regression locks against
    the in-repo fixture corpus, byte-exact against BW ASCII export
    for peaks (all 4 channels), frequencies (all 4 channels,
    including >100 Hz sentinel handling), block framing, and
    segment-ID accounting.

  scripts/backfill_sidecars.py (modified) — the has_samples
    short-circuit added in the histogram-pending era is now a
    pure defensive guard.  Histograms in prod will regen .h5 files
    correctly on the next backfill run.

  docs/histogram_codec_re_status.md (updated) — supersedes the
    earlier "in progress" version with the verified format and
    test-coverage summary.  Notes a few non-essential fields still
    open (4-byte block metadata, Geo PVS, Mic psi(L) — none of
    which are needed for waveform reconstruction).

Total verified coverage: ~3,500 blocks across 5 fixtures, every
field of every block byte-exact against BW.

The watcher-forwarded histogram event corpus on prod (~10,000
events) will now produce correct .h5 sidecars on the next backfill
run.  No additional changes needed to the backfill flow — the
existing tool_version-bump cascade picks them up automatically.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-20 23:05:13 +00:00
serversdownandClaude Opus 4.7 c3c7fe559c docs: histogram body codec RE — starting-point status doc
Captures everything learned in the 2026-05-20 session before scope
forced a pause:

  - Block framing is solved: 32-byte blocks, one per histogram
    interval, signature byte pattern `[22:24]=0x0000` +
    `[28:32]=0x1e 0x0a 0x00 0x00` reliably identifies data blocks.
  - Block count = interval count (791 blocks in N844L20G.630H for
    a TXT-reported 792 intervals).
  - Sample[0] = Tran peak in 0.0005 in/s/count units (verified on
    one event — needs cross-event confirmation).
  - Samples 1-8 → channel/metric mapping is still open.  None of
    the obvious layouts (peak-then-freq alternating, all-peaks-
    then-all-freqs, per-channel 3-tuples) match the TXT values
    across multiple blocks.  Likely needs a higher-activity
    fixture (current N844 corpus is all noise-floor data) to
    disambiguate.
  - `>100 Hz` sentinel encoding in the binary is unknown.
  - 4-byte variable metadata field at block[24:28] needs
    correlation work against TXT columns.

Doc mirrors the structure of docs/waveform_codec_re_status.md so
a future RE session has a familiar entry point.  Includes the
suggested attack plan + the code seam where the eventual decoder
will land (minimateplus/histogram_codec.py).

The §7.6.2 spec in instantel_protocol_reference.md is structurally
correct but doesn't pin down per-sample semantics — this doc
supersedes it where they conflict on confidence level.

No code shipped on this branch.  When the codec is cracked, the
plan is to land minimateplus/histogram_codec.py + wire into
event_file_io.read_blastware_file() + remove the has_samples
short-circuit from scripts/backfill_sidecars.py.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-20 21:13:26 +00:00
serversdown beca5de06e docs: clean up and verify s3 protocol docs 2026-05-20 17:55:02 +00:00
serversdown d85df4c886 Merge pull request 'merge full s3 codec decoded' (#23) from codec-re into main
Reviewed-on: #23
2026-05-20 13:45:32 -04:00
Claude 0466bb4f44 codec: crack wide-NN blocks (1X NN / 2X NN); loud events now fully decode
When NN exceeds 0xFC, the codec extends to 12-bit NN by using the
low nibble of the TYPE byte as the high nibble of NN:

    1X NN  →  nibble-delta block, NN = (X << 8) | NN_byte
    2X NN  →  int8-delta block, same NN encoding

Walker and decode_waveform_v2 now handle both narrow (X=0) and wide
(X != 0) forms uniformly.

Discovered while investigating why SP0/SS0/SV0/event-b walkers stopped
mid-event.  SP0 segment 12 (V continuation, cycle 3) starts with
"11 90" — high nibble of byte 0 = 1 (= nibble-delta block type), low
nibble = 1 plus byte 1 = 0x90 → NN = 0x190 = 400 nibble deltas in
202 bytes.  Walker was rejecting "11" as a non-tag.

Sample count went from 47,364 to 72,972 verified byte-exact:

  event-a:  9984 (full)        was 9984 (full)
  event-b:  6912 (full)        was   738
  event-c:  3840 (full)        was 3840 (full)
  event-d:  3840 (full)        was 3840 (full)
  JQ0:      9984 (full)        was 9984 (full)
  V70:      9984 (full)        was 9984 (full)
  SP0:      9984 (full)        was 5122
  SS0:      9222 (-7 tail)     was 1758
  SV0:      9222 (-7 tail)     was 2114

7 of 9 fixtures now decode end-to-end across all 3 geo channels.
The 2 remaining (SS0, SV0) are missing only 1-7 tail samples per
channel — minor walker edge case at the very end.

74 tests pass (was 71).
2026-05-20 17:28:54 +00:00
Claude 85f4bcfe86 codec: wire decode_waveform_v2 into production; add MicL dB helper
Replaces the broken legacy int16 LE decoder in client.py with the
verified multi-channel codec.  Three changes:

1. blastware_file.extract_body_bytes(a5_frames) — new helper that
   factors out the body-reconstruction logic from write_blastware_file
   so both writers (BW binary) and decoders (sample arrays) can use
   the same canonical bytes.

2. waveform_codec.decode_a5_frames(a5_frames) — production entry point.
   Returns the raw_samples dict consumers expect (Tran/Vert/Long as
   int16 ADC counts; MicL as native ADC counts).  Internally:
     A5 frames → extract_body_bytes → decode_waveform_v2
                → decoded_to_adc_counts (geos ×16; mic pass-through)

3. waveform_codec.mic_count_to_db(count) — MicL ADC → dB(L) per BW's
   display formula:
     dB = sign(count) × (81.94 + 20 × log10(|count|))   for |count| ≥ 1
   Verified against V70 fixture: count=813 → 140.14 dB (BW PSPL 140.1).

client.py:_decode_a5_waveform is reduced to a thin wrapper that calls
decode_a5_frames and populates event.raw_samples.  Original implementation
preserved as _decode_a5_waveform_LEGACY (dead code; reference only).

Also fixed a tail-end bug in decode_waveform_v2 where trailer-section
"40 02" markers (containing ASCII serial bytes, NOT real segment headers)
were being mis-interpreted, producing 2 spurious samples per channel at
the end of each event.  Added bytes [12:14] == "02 00" validation to
reject non-header markers.

7 new pytest tests cover the new helpers and dB conversion.  Total:
71 passing (up from 64).

Known limitation (carried over from before): the walker still stops
mid-event on the loudest fixtures (SP0/SS0/SV0/event-b) at some
mid-segment edge cases not yet characterized.  Every sample reached
is decoded correctly; the walker just doesn't reach all of them.
Loud events still yield 5,000–15,000 byte-exact samples each.
2026-05-20 17:28:54 +00:00
Claude 2ff2762eec codec-re: 30 NN block CRACKED — codec fully decoded
User intuition (16-bit) + 12-bit packing hypothesis + the int16 ADC
range constraint led to the final piece.

30 NN block format (CONFIRMED across all 14 blocks in the fixture
bundle):

  NN 12-bit signed deltas packed as NN/4 groups of 6 bytes each.
  Within each group:
    bytes [0:2] = 16 bits = 4 × 4-bit high nibbles (MSB-first)
    bytes [2:6] = 4 × int8 low bytes
    delta[k] = sign_extend_12((high_nibble[k] << 8) | low_byte[k])

  Block length = NN × 1.5 + 2 bytes (tag included).  Earlier walker
  used NN × 4 which is only correct in the TRAILER section.

Why 12-bit:  ±2047 in 16-count units ≈ ±10 in/s = the geophone's
full-scale range at Normal sensitivity.  The codec sizes its widest
delta to cover the worst-case sample-to-sample change.

Results: every decoded sample across all fixture events matches truth
byte-exact.  ZERO divergences.

  event-a:  9984 samples (full event, all 3 geos)
  event-c:  3840 (full event)
  event-d:  3840 (full event)
  JQ0:      9984 (full event)
  V70:      9984 (full event)
  SP0:      5122 (walker stops early on edge cases)
  SS0:      1758
  SV0:      2114
  event-b:   738

  TOTAL: 47,364 ADC samples verified, zero errors.

Three full 3-sec events decode end-to-end across all three geo
channels.  The events where fewer samples decode (SP0/SS0/SV0/event-b)
are limited by walker robustness issues past the first few segments,
NOT by decoder correctness.

64 tests pass (up from 55).  Files: minimateplus/waveform_codec.py
(new 30 NN decode + corrected walker length), tests/test_waveform_codec.py
(new full-event regression tests), docs/* (updated status everywhere),
analysis/test_30nn_hybrid.py (new — the analysis script that confirmed
the format).
2026-05-20 17:28:54 +00:00
Claude ce5dc640ba codec-re: quiet bundle decodes FULLY (17k samples, zero errors)
User asked the right question: do events without 30 NN blocks decode
fully?  Answer: YES.

  event-a:  Tran 3328 ✓  Vert 3328 ✓  Long 3328 ✓  (28 segments, 0 '30 NN')
  event-c:  Tran 1280 ✓  Vert 1280 ✓  Long 1280 ✓  (12 segments, 0 '30 NN')
  event-d:  Tran 1280 ✓  Vert 1280 ✓  Long 1280 ✓  (12 segments, 0 '30 NN')

17,664 ADC samples decoded byte-exact against BW's ASCII export.
Zero divergences across event-a, event-c, event-d.

This means the codec is FULLY SOLVED for any event without 30 NN
blocks.  The remaining gap is the 30 NN block format only — used for
high-amplitude regions where deltas exceed int8 range.  For quiet
events (or quiet stretches of loud events), the decoder is complete.

9 new regression tests bring the total to 55, all passing.

Files: tests/test_waveform_codec.py + docs/waveform_codec_re_status.md
+ new analysis/verify_quiet_bundle.py.
2026-05-20 17:28:54 +00:00
Claude 07675626dc codec-re: channel rotation CONFIRMED — full multi-channel decoder works
The segment-channel scoring analyzer (from scratch/next_experiment_skeleton.py)
ran and immediately confirmed the rotation hypothesis:

  SP0 seg 0: best fit Vert  508/508  ✓
  SP0 seg 1: best fit Long  508/508  ✓
  SP0 seg 3: best fit Tran  508/508  ✓  (Tran continuation)
  SP0 seg 5: best fit Long  508/508  ✓
  SP0 seg 9: best fit Long  508/508  ✓
  V70 seg 0: best fit Vert  508/508  ✓
  V70 seg 1: best fit Long  508/508  ✓

Channels rotate Tran → Vert → Long → MicL per 40 02 segment header.

Also discovered the segment header has DOUBLE duty: bytes [14:18] anchor
the NEW segment's channel (2 samples as int16 BE in 16-count units), AND
bytes [0:4] extend the PREVIOUS channel by 2 more samples (2 deltas as
int16 BE).  This is the same "2 anchors + delta stream" structure as the
body preamble for Tran.

decode_waveform_v2 now returns full per-channel sample dicts.
Byte-exact verified ranges:
  V70: Tran 512, Vert 512, Long 512   (all first segments)
  JQ0: Tran 512, Vert 258
  SP0: Long 1536 (all 3 L segments)

Still open: the 30 NN block format (high-amplitude packed deltas) —
appears mid-segment when single-byte deltas can't carry the magnitude.

6 new tests bring the count to 46.  All passing.
2026-05-20 17:28:54 +00:00
Claude f68ee9f0f9 docs: clean up waveform-codec doc layers per review
Three "truth layers" had drifted apart between commits.  Fixed:

1. waveform_codec.py docstring rewritten from the 2026-05-08
   "structural framing only" state to the 2026-05-11 "Tran segment 0
   solved + segment-header partially decoded" state.  Killed stale
   "~80 sample-sets per segment" language (real segments are
   flash-page-byte-sized, not sample-count-sized; observed first-segment
   sizes are 42-510 samples depending on signal).  Killed stale
   "preamble is 7 or 9 bytes" language (always 7).

2. docs/instantel_protocol_reference.md §7.6.1: added a clear
   "CURRENT STATUS" box at the top with a status table.  Replaced the
   stale "~80 sample-sets" line with the verified per-event segment
   sizes.  Merged two redundant segment-header field-table sections.

3. docs/waveform_codec_re_status.md (NEW): clean working-status doc.
   Solved / not solved / hypothesis / next experiment / fixtures /
   tests.  The protocol reference remains the historical Rosetta
   Stone; this new file is the current-truth working note that
   shouldn't accumulate fossil layers.

4. CLAUDE.md §"Waveform body codec": prominent warning box at top —
   "DO NOT TRUST decoded sample arrays yet."  BW binary passthrough
   is the only sample-bearing output to trust until the decoder
   lands.  Added a "Next experiment" subsection pointing the next
   pass at the segment-channel scoring analyzer.

40 tests still pass.
2026-05-20 17:28:54 +00:00
Claude a0c9a482c7 codec-re: 00 NN is RLE; full Tran segment-0 decode (4 of 5 events)
User uploaded a Vert-heavy event (JQ0) and a Mic-heavy event (V70).
Those two were exactly what was needed to crack the next piece:

- 00 NN block = run-length-encoded zero deltas in the current channel.
  Append NN copies of the current cumulative value (no change).
- find_data_start now recognizes 00 NN as a valid first tag (some events
  begin with a leading 00 NN RLE block).
- decode_tran_initial now decodes the FULL segment 0 (not just the first
  data block).

Results across 5 fixture events:
  - M529LL1A.SP0 (loud-all-channels)  : 510 / 510  ✓
  - M529LL1L.JQ0 (Vert-heavy)         : 510 / 510  ✓
  - M529LL1L.V70 (Mic-heavy)          : 510 / 510  ✓
  - M529LL1A.SV0 (loud-from-start)    :  58 /  58  ✓
  - M529LL1A.SS0 (loud-from-start)    :  42 / 502  (stops at first 30 04)

The 30 04 block (only seen in loud-from-start events) hasn't been
decoded yet — likely a channel-switch marker for the high-amplitude
regime.

Also discovered: segment header (40 02) payload bytes [0:2] = T_delta
at first sample of new segment, [6:8] = byte length to next segment.
Multi-segment Tran decoding still diverges after sample 512 because
the per-segment channel ordering after the header is unknown.

Tests: 40 pass (up from 36).

Files:
- minimateplus/waveform_codec.py: find_data_start fix, RLE handling,
  full segment-0 decode in decode_tran_initial
- tests/test_waveform_codec.py: synthetic RLE test, full segment 0
  tests for JQ0 and V70
- tests/fixtures/5-11-26/: M529LL1L.JQ0, M529LL1L.V70 + TXT exports
- docs/instantel_protocol_reference.md §7.6.1: RLE + segment-header docs
2026-05-20 17:28:54 +00:00
Claude 6ac126e05c codec-re: crack Tran channel codec with high-amplitude May 11 bundle
User uploaded 3 high-amplitude events (PPV 6-7 in/s — shook the geophone
hard) to decode-re/5-11-26/.  These cracked the Tran codec:

- Preamble bytes [3:5] and [5:7] = Tran[0] and Tran[1] as int16 BE
  in 16-count units (LSB = 0.005 in/s).  Confirmed across all 7
  fixtures.
- First data block carries Tran deltas from sample 2 onward:
  * 10 NN block: NN/2 bytes of payload, each byte = two 4-bit signed
    nibble deltas (high nibble first)
  * 20 NN block: NN int8 signed deltas

Verified 22+42+46 = 110 Tran samples across SP0/SS0/SV0 with 0 errors
against BW's ASCII export.

Why the earlier 96-combination brute force failed: the quiet 5-8
events all had T[0] = T[1] ≈ 0 so the preamble's per-channel encoding
was undetectable.  Loud events made the encoding obvious.

What's solved:
- minimateplus.waveform_codec.decode_tran_initial: returns first
  N Tran samples in 16-count units for any body.
- Walker length formula for in-data 30 NN blocks (NN*2 instead of NN*4).
- Walker now handles bodies that start with 20 NN (in addition to 10 NN).

What's still open:
- Tran past the first data block (multi-block channel switching).
- Vert / Long / MicL channel encodings.
- Walker correctness past offset ~427 in event-b.

Tests: 36 pass.  decode_waveform_v2 still returns None — the full
multi-channel decoder is not wired up.  decode_tran_initial is the
new verified entry point.

Files: minimateplus/waveform_codec.py, tests/test_waveform_codec.py
(adds 5-11-26 fixtures + decode_tran_initial tests), and
docs/instantel_protocol_reference.md §7.6.1 (Tran codec spec).
2026-05-20 17:28:54 +00:00
Claude d3f77d1d96 codec-re: solve waveform body block framing; per-byte sample mapping still open
Decoded the structural framing of the Blastware waveform body — the bytes
between the 21-byte STRT record and the 26-byte file footer.  The body is
a sequence of tagged variable-length blocks, NOT raw int16 LE.  Five tag
types (10/20/00/30/40 NN) and their lengths are now confirmed against the
4-event May 2026 fixture bundle.  Body splits cleanly into ~16 segments
(for a 1280-sample event) separated by 40 02 segment headers carrying a
monotonically incrementing uint32 LE counter at bytes [8:12].

What's done:
- minimateplus/waveform_codec.py — block walker, segment splitter, segment
  header parser.  decode_waveform_v2 is a stub returning None until the
  byte-to-sample mapping is solved; client.py is unchanged.
- tests/test_waveform_codec.py — 31 tests covering block detection, lengths,
  contiguous-walk, segment splitting, segment-header parsing, and counter
  monotonicity.  All pass.
- tests/fixtures/decode-re-5-8-26/ — bundled fixtures (4 events, BW binary
  + Blastware ASCII export each).
- docs/instantel_protocol_reference.md §7.6.1 — replaced retraction box
  with the verified structural decoding plus an explicit list of what's
  still open.

What's still open: the per-byte mapping inside 10 NN / 20 NN blocks.  96
channel-permutation × nibble-order × sign-convention combinations were
brute-force tested; none match BW's ASCII export to within ±1 ADC count.
The codec is more elaborate than uniform 4-bit deltas — likely a hybrid
variable-bit-width scheme with segment-anchor resync points.  Next
recommended step: capture an event with a known calibration tone to pin
down magnitude scaling.

Walker also bails out partway through event-b (open issue documented in
both the module and the protocol reference).
2026-05-20 17:28:54 +00:00
Claude 8316a1bbd8 docs(protocol): accuracy sweep across the protocol reference
Three-pass audit of docs/instantel_protocol_reference.md against
CLAUDE.md and the minimateplus/ implementation. Closes long-standing
discrepancies that had accumulated as the protocol understanding
evolved month over month.

Major corrections:
- §2/§3: S3 frames terminate on bare ETX, not DLE+ETX; payload
  byte[1] is flags / byte[2] is SUB (was wrongly DLE/ADDR).
- §4.2: probe responses do not carry data length; DATA_LENGTH
  is a per-SUB hardcoded constant.
- §5.1: dropped stale duplicate "SUB 1C = TRIGGER CONFIG READ"
  row; SUB 0A lengths corrected from 0x30/0x26 to 0x46/0x2C.
- §5.3: added the missing write-frame mechanics (BW_CMD-only
  doubling, DLE-aware checksum, offset = data[1]+2, ack format,
  SUB 71 chunk parameters).
- §7.6.x: switched compliance-anchor convention from the unstable
  10-byte form to the canonical 6-byte `\xbe\x80\x00\x00\x00\x00`;
  recording_mode confirmed at anchor−8 in both read and write
  (the prior anchor−3/−4 split caused anchor drift on write).
  Sample_rate at anchor−6, histogram_interval at anchor−4 (now ✅),
  record_time at anchor+6. Geo_range row added at channel_label+33.
- §7.5b/§8: added the 10-byte sub_code=0x03 continuous-mode
  timestamp variant; peak vector sum location corrected from
  fixed offset 87 to label-relative tran_pos−12.
- §7.7.2: SUB 1E/1F token byte at params[7], not params[6].
- §7.7.3: SUB 0A length disambiguation rewritten.
- §7.8.4/§7.8.7: fi==9 skip marked FIXED; metadata-page TODO
  replaced with current decoder state.
- §11: POLL example wire bytes corrected; SUB 5A row added to
  checksum table.
- §13/§14: device-under-test updated to BE11529/S338.17; TCP
  Idle Timeout consistency fix (0→2 min); Data Forwarding
  Timeout units clarified.
- §15 (renumbered from second §14): open-question entries
  already resolved in CLAUDE.md closed out.
- Appendix D: extension taxonomy rewritten — extensions encode
  a timestamp (AB0T scheme), not recording mode.

Navigation note added to §7 acknowledging the organic-growth
duplicate section numbers (§7.5/§7.5b, §7.6, §7.7, §7.8, §7.9)
and pointing readers to the canonical sections for each topic.

https://claude.ai/code/session_019tWZybD94YUsBaEGhnM5A2
2026-05-20 15:41:42 +00:00
serversdown ecc935482b seismo-relay v0.19.0 — device-family separation + micromate/ package
Tighten the Series III / Series IV boundary so UI and storage dispatch
on a clean signal instead of sniffing filenames or applying magnitude
heuristics.

Phase 1 — events.device_family column ("series3" | "series4"):
  self-applying migration with filename-based backfill of existing rows
  (1,132 backfilled on prod 2026-05-20); plumbed through every import
  path (BW endpoint, IDF endpoint, ACH server, BW CLI, sidecar
  backfill); UPSERT preserves via COALESCE; UI dispatches on it.

Phase 2 — extract micromate/ package alongside minimateplus/:
  native IdfEvent / IdfReport / IdfPeaks / IdfProjectInfo /
  IdfSensorCheck (mic in dB(L), not pseudo-psi); moved
  idf_ascii_report.py from sfm/ to micromate/; refactored
  save_imported_idf to use IdfEvent and bridge to minimateplus.Event at
  the SQL-insert boundary; idf_file.py stub for the future binary codec.

Phase 3 prep — docs/idf_protocol_reference.md captures the two
observed Thor binary header signatures (1,012 newer-firmware files vs
2 old files whose layout is byte-for-byte BW-STRT-compatible), file-size
hints suggesting int8 sample encoding, open questions in dependency
order, and a concrete first-session plan for cracking the codec.

Also rolled in the v0.18.1 hotfixes that motivated this work:
  - idf_ascii_report parser now handles "<0.005 in/s" (below-threshold)
    and "N/A" markers without leaving raw strings in numeric DB columns.
  - sfm_webapp.html: defensive _ppvFmt / mic formatter so future
    data-shape drift can't kill the whole events table render.

All 1,014 example-data sidecars round-trip through the new package.
See CHANGELOG.md for full notes.
2026-05-20 15:19:49 +00:00
serversdown 1fff8179d6 Add runbook for recovering wedged units and new scripts for device management
- Created a comprehensive runbook (`wedged_unit_recovery.md`) detailing the recovery process for units stuck in a call-home loop, including symptoms, recovery steps, and explanations of the failure mode.
- Added `blind_stop.sh` script to send stop-monitoring commands in a tight loop for unresponsive devices.
- Introduced `rescue_device.sh` script to disable Auto Call Home and erase events from a busy device.
- Implemented `slow_drip.sh` script to send stop-monitoring frames at a slow rate to prevent UART overrun.
- Developed `spam_stop.sh` script to rapidly send stop-monitoring commands to a device.
- Created `watch_unit.sh` script for passive monitoring of device reachability, logging results over time.
2026-05-17 07:58:13 +00:00
serversdown 8aea46b8a0 doc(fix): retracts raw int16 LE sample set assumptions. 2026-05-08 19:26:25 +00:00
claude c914a15e12 docs: update for v0.14.3 - Full continuous waveform download successful! 2026-05-05 20:37:52 -04:00
claude 7444738883 debug(protocol): event-N probe is now at counter = start_offset instead of start_offset + 0x46 2026-05-05 16:46:35 -04:00
claude 1ef55521b1 Fix: Removed duplicates from merge botch. Stable version of seismo_lab.py 2026-05-01 17:34:41 -04:00
claude 2f084ed105 fix(protocol): update chunk counter formula to use max(key4[2:4], 0x0400) for accurate data streaming 2026-04-26 01:28:47 -04:00
claude 35c3f4f945 fix(protocol): correct A5 frame classification and chunk counter formula 2026-04-24 17:25:29 -04:00
claude aa2b02535b fix(protocol): add record_time based chunk scaling for longer event record times 2026-04-23 17:33:16 -04:00
claude 6dcca4da79 feat(protocol): fully decode Blastware filename encoding and update related documentation 2026-04-22 23:43:31 -04:00
claude c47e3a3af0 feat(protocol): update Blastware file format documentation and encoding details 2026-04-22 19:16:05 -04:00
claude dfbc9f29c5 feat: first try at building waveform binary files. 2026-04-21 22:57:53 -04:00
claude 4331215e23 feat(protocol): enhance raw capture functionality and documentation updates
- Update `s3_bridge.py` to default raw capture file paths to "auto" for timestamped naming.
- Modify `gui_bridge.py` to pre-check raw capture options and streamline path handling.
- Extend `ach_server.py` to save both incoming and outgoing raw bytes for analysis.
- Revise `CHANGELOG.md` and `instantel_protocol_reference.md` to reflect changes in recording mode handling and compliance data encoding.
2026-04-21 16:07:24 -04:00
claude 3fb24e1895 feat(call-home): Implement Auto Call Home configuration management
- Added `CallHomeConfig` model to represent the Auto Call Home settings.
- Introduced methods in `MiniMateClient` for reading (`get_call_home_config`) and writing (`set_call_home_config`) the call home configuration.
- Updated `MiniMateProtocol` with new commands for call home operations (SUB 0x2C for read, SUB 0x7E for write, and SUB 0x7F for confirm).
- Created API endpoints for retrieving and updating call home settings in the server.
- Enhanced the web interface with a new "Call Home" tab for user interaction with call home settings.
- Implemented JavaScript functions for reading and writing call home configurations from the web app.
2026-04-20 18:23:48 -04:00
claude b6ffdcfa87 feat: implement geophone sensitivity and recording mode settings in compliance config 2026-04-20 17:03:58 -04:00
claude e04114fd6c feat: mapped record_mode protocol 2026-04-20 15:49:31 -04:00