Commit Graph
192 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 ca5c401c6f fix(device_access): a start's read-back waits out the sensor check, then wakes the MiniMate with retries
Second start through SFM, BE9441 2026-10-26 23:54:41: acked 0x69, and Brian saw
'starting, performing sensor check, recording' -- but the read-back's single
SESSION_RESET + POLL went out 2.3 s after the ack, inside the ~30 s sensor
check, and was never answered or re-sent (504 after 120 s, audit ca7b5b42).
Brian: every unit is set to sensor-check before monitoring, ~30 s, then
'Recording...'.

- MiniMateProtocol.wake(attempt_s, deadline_s): SESSION_RESET + POLL re-sent
  every attempt_s until the unit answers, then the POLL data step; a named
  timeout at the deadline.  Reads only.  MiniMateClient.wake() wraps it.
- The Series-3 change: after a START, the first read waits S3_SENSOR_CHECK_S
  (30 s) before asking; every read then wakes with retries (every 5 s, up to
  60 s).  A stop is unchanged -- its read-back was confirmed three times tonight.

Tests: a unit deaf for 4 probes is asked a 5th time and answers; a unit that
never answers ends in the named timeout after ~6 probes; a start's first read
waits the sensor check, a stop's does not; every read is preceded by a wake.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:02:10 -04:00
serversdownandClaude Opus 5.5 9886422212 fix(device_access): wake a MiniMate before every state read in a start/stop, so a start's read-back is answered
BE9441, 2026-10-26 23:41:48 (through the bridge): SFM's start (0x96, Blastware's
own bytes) was acked 0x69 and the unit began monitoring -- Brian saw it -- but
the read-back sent one bare 0x1C two seconds later and got nothing for 120 s,
so the change reported 'sent and acknowledged, but reading the state back
failed' (504, audit 0c1cf813).  Nothing was retried.

A monitoring MiniMate ignores a bare request until SESSION_RESET + POLL
(measured 2026-04-08).  The read-back had relied on the connect's wake; a stop's
read-back (18:53, the unit idle by then) never needed it.  Every state read in
the change now goes through _woken_state: client.poll() (41 03, POLL, 41 03,
POLL -- the connect's own sequence), then 0x1C.

Test: after the send, every 0x1C read is preceded by a POLL.  No codec, store or
DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 23:51:15 -04:00
serversdownandClaude Opus 5.5 d990466407 fix(minimateplus): the 0x1C status reads a histogram run as monitoring, and unescapes before counting from the end
Measured on BE9441 tonight, through the recording bridge:

- Monitoring flag 0x0B while recording a histogram (confirmed at the unit), 0x00
  idle.  Only 0x10 had been measured as monitoring (BE11529, 2026-04-08), so the
  status showed 'not monitoring' and the change path refused the state as
  unknown(0x0B) -- refused, not skipped, which is the design working.  0x0B joins
  S3_RUN_STATES and S3_MONITORING_FLAGS as measured.  The shared status's
  'monitoring' now follows the change path's reading: None for an unmeasured
  flag, never a guessed False.
- Free memory 0x000D0E04 arrived as 0d 0e 10 04.  The parser keeps the 10 of a
  10 02/03/04 escape, so every field counted from the end read one byte off:
  419.84 V and 251,655,168 bytes for 6.76 V and 983,028.  New
  framing.unescape_reply() (also used by parse_strt_end_key) runs first.

Tests: the two recorded replies (idle 16:24, monitoring 18:47) decode to the
unit's own values; each escaped value in the last ten bytes decodes; the status
mapping for 00 / 10 / 0B / unmeasured.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 18:53:11 -04:00
serversdownandClaude Opus 5.5 6f31eca366 docs: the 64 KB page bug is fixed; the 5A 'non-standard frame' model retracted in place
CLAUDE.md: the KNOWN BUG entry marked fixed (887e75d) with what settled it, and
retraction notes under the 5A sections that described the misreading (partial
stuffing, offset_hi 0x10 raw, 11-byte params, metadata pages 0x1002/0x1004).
Series-III reference: a 2026-10-26 (3) row.  Spec: the MiniMate check updated.
Code comments that called the page bug open, updated; the adapter's struct.error
mapping kept as a defence, its message and test no longer naming the old bug.

Verified live on BE9441 the same day: all 8 events downloaded by serial, the 4
that cross a 64 KB page included, each whole and matching the unit's own peaks.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 14:44:11 -04:00
serversdownandClaude Opus 5.5 c32a9e7851 fix(sfm): a MiniMate download that decodes as nothing is refused, not stored as a histogram
Review of 36f4e5d (measured): with the metadata-page bug put back, 4 of 7
BE12599 non-first waveforms decoded to nothing, and the check stored them
unverified as 'a histogram' -- the worst form of the bug it was built for.
Now: no waveform decode must decode as a histogram (stored unverified) or it is
refused; a waveform's record chain must end on its END record (0x06), as the
file reader requires -- cut-short streams have none; the structure checks run
for every unit and only the peak comparison is limited to a unit confirmed in
normal range (geo_range == 0; an unread range is no longer assumed normal);
a clipped blast at full scale on both sides counts as a match.  Tests pin the
one-step tolerance, both ranges, the END record and the neither case.

No DB or schema change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:47:39 -04:00
serversdownandClaude Opus 5.5 36f4e5d985 feat(sfm): a MiniMate download is checked against the unit's own peaks before it is stored
Series 4 downloads were checked (decoded PVS against the unit's); Series 3's
were stored unchecked (verified=None), so BE9441's two bad files went in as
successes at the bench (2026-10-25).  verify_s3_download(): if the waveform
decodes, all three geophone channels must be the same length and each peak must
be the unit's own 0C peak to one 0.005 in/s step, or the download is refused
(MalformedReply, "not saved").  Unverified (stored, as before): no waveform
decode -- a histogram; 0 of ~430 fixture histograms decode as one -- or a
sensitive-range unit, whose scale is still open.  The reason goes in
detail["check"].

A test puts the metadata-page bug back and the check refuses the file it
produced.  Session-replay helpers move to tests/minimate_replay.py.

No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:14:44 -04:00
serversdownandClaude Opus 5.5 cdc6360ec0 fix(sfm): an audit finish that fails on a hang-up path still releases the line
The final fix wave's AuditIncomplete landed in _exchange's `except DeviceError`,
which keeps the line -- so on the nine ring / link-fault paths (and a refusal) a
failed audit write turned a hang-up into a held Series-4 line, blocking a THOR
call-home for up to the 5-minute idle hang-up and making "SFM hung up" false.
AuditIncomplete now carries release_line, set by every finish whose path hangs
up anyway, and _exchange honours it.  Also pins the Series-3 change path's
retry=False again (the rewritten lost-ack test no longer could).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:36:00 -04:00
serversdownandClaude Opus 5.5 8f68b09f5e fix(sfm): a change that fails after the send says so; the audit row records sent + states; S3 unknown states refused
Final fix wave for phase 3 (start/stop monitoring), per the whole-phase review.

- I1 + M2: every failure after the send has started is a ChangeUnconfirmed
  (audit_id, sent = "acknowledged" | "unknown", the cause's HTTP status) whose
  message says the frame was sent and names the audit record -- the ring in
  place of the ack, the four lost-ack follow-ups, and the three read-back
  paths.  Series4Session releases the line on it.  Every audit finish goes
  through one helper; a finish that fails is AuditIncomplete (500) and still
  says what happened to the unit.  The line is kept.
- I2: device_commands gains `sent` (1 acknowledged, 0 nothing sent, NULL
  unknown) and `states` (before / seen / after), with an idempotent ADD COLUMN
  in _migrate for a table created earlier on this branch.
- M1: a RADIO RING already buffered is caught before 0x96/0x97 goes out
  (pre_send = read_unsolicited, one 10 ms transport read).  That is a
  CallHomeInProgress with sent=0, not ChangeUnconfirmed.
- M3: Series 3 reads the raw 0x1C flag (new MonitorStatus.state_flag); a byte
  other than 0x00/0x10, or a short section, is unknown(...) and refused.
- M8: even_if_already on a unit already in the state notes that the read-back
  proves nothing.
- M10: a scan pins `.protocol.execute(` to sfm/device_access/s4.py; both
  scans fail closed on a file that does not parse.
- M11: docs corrected (CLAUDE.md phase-2 sentence, phase-3 bullet, REST list;
  micromate/protocol.py scope and the 0x49 read_state docstring; s4.py; route
  docstrings).  "No command has ever been originated" is NOT retracted.
- M12: GET /db/device_commands normalises the serial.
- Minors: unused imports, S3 dry-run frames and 120 s timeout pinned, test
  rename, serial-cache and short-0x49 tests, _RUN_STATES comment.

Schema: two NULLable columns on the branch-new device_commands table, added
by _migrate on open; no backfill.  No codec change, TOOL_VERSION unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:16:45 -04:00
serversdownandClaude Opus 5.5 ac33c8ffa4 fix(sfm): start/stop HTTP status is an allow-list -- only verified, skipped or dry-run is 200
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 17:00:31 -04:00
serversdownandClaude Opus 5.5 c3e7e169c0 feat(sfm): start/stop monitoring by serial -- dry run, audit, read-back
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:57:47 -04:00
serversdownandClaude Opus 5.5 ce5d2cb0d6 feat(sfm): start/stop monitoring for Series 3 through the same safety layer
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:48:05 -04:00
serversdownandClaude Opus 5.5 78c3d568d5 test(sfm): pin the ring-on-follow-up and calling-home poll exits; narrow the refusal clause
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:45:02 -04:00
serversdownandClaude Opus 5.5 14ea80f5a4 fix(sfm): a ring or a refusal is never mistaken for a send; fresh serial pinned; unmeasured states refused
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:39:55 -04:00
serversdownandClaude Opus 5.5 eada7ba767 feat(sfm): start/stop monitoring for Series 4 -- identity, state, dry run, audit, read-back, never retried
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:29:03 -04:00
serversdownandClaude Opus 5.5 ff0cce1cb2 fix(sfm): an audit row can be finished once, from pending -- anything else raises
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:24:46 -04:00
serversdownandClaude Opus 5.5 fb9b48f259 feat(sfm): device_commands audit table -- one row per change attempt
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:22:28 -04:00
serversdownandClaude Opus 5.5 a130107fdf fix(sfm): a Series-4 record whose timestamp did not decode is not called stale
Mirrors the Series-3 fix (F3): an unreadable 0C timestamp is a decode or
comms fault, not proof the unit was erased.  Nothing is downloaded.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:58:18 -04:00
serversdownandClaude Opus 5.5 2a70faf7b5 docs(sfm): state the held-line invariant, pin the hang-up on a library error, correct the README
- Series4Session's docstring now states which errors keep the line: an
  op raises a DeviceError only for a verdict on a healthy link (not
  found, stale, unnameable), and _exchange keeps the line for those; any
  library error means the link is suspect and hangs up.  DecodeMismatch
  is a library error and hangs up -- conservative.  Later ops must keep
  to it.
- Test: a micromate TimeoutError mid-download, on a fresh DeviceAccess
  (no retry path), is NoAnswer, closes the client once and leaves no held
  line.  It pins existing behaviour; a mutation that keeps the line on
  library errors makes it fail.
- README, event rows corrected in place: another unit's id is 422 (not
  409); a stale id is 409 without downloading, both series; an event
  already stored -- including by THOR's watcher -- returns its row and
  changes nothing (detail.already_stored); MiniMate lists give
  record_type null, on the normal timeout, and fail on a lost reply.

No code behaviour change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:41:26 -04:00
serversdownandClaude Opus 5.5 4e1e6a9d5c fix(sfm): Series-3 events list with no record type, not a wrong one
minimateplus's _extract_record_type returns "Waveform" for every 0C
record layout -- it cannot tell a histogram -- so a MiniMate histogram
was listed as "waveform".  The fake's "Histogram" was a value the real
client never produces, which is why no test saw it.

- _s3_ref: record_type is always None, with
  detail.record_type_note = "Series 3's event record does not say
  waveform or histogram; not decoded yet".
- default_s3_events(): both events "Waveform", as the real client gives.
- The shared-shape contract test allows exactly {"record_type"} to be
  None for Series 3 and nothing for Series 4.

Rows SFM stores for Series 3 still carry "Waveform" from the decode (the
same as the legacy blastware_file route); parked in the spec.  No codec,
store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:40:26 -04:00
serversdownandClaude Opus 5.5 59dff06f1c fix(sfm): the Series-3 header walk fails loudly, and listing uses the normal timeout
One lost 1F reply made the list return 1 of 3 events as a 200, and on a
download gave a false 404.  The list also ran on the 120 s download
timeout, so each lost reply stalled the walk 120 s with the unit locked.

- get_events() strict mode (headers_only, or only_key): a lost 0A reply,
  a lost 1F(browse) reply on the success path and on the partial-record
  path all re-raise their ProtocolError; a 1F that hands back a key
  already walked raises ProtocolError("event chain did not advance ...").
  Legacy calls (none of the new options) behave exactly as before --
  pinned by tests of the same three faults under get_events().
- Series3Adapter.list_events runs on the default timeout (10 s on TCP);
  download_event keeps 120 s.
- FakeProto gains optional lost-reply injection; its default is unchanged.

The repeat-key guard sits at the loop head, which is reached only for a
non-null key -- equivalent to checking each 1F's key, in one place.

Read-only; nothing new on the wire.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:39:54 -04:00
serversdownandClaude Opus 5.5 01b9188f25 fix(sfm): a stale Series-3 id is refused before the full download, not after
Series3Adapter.download_event compared the timestamp only after
download_event_by_key had run the whole 5A.  A stale id cost a full
download of the wrong event (minutes on cellular), could surface the
64 KB-page 502 instead of 409, and a lost 0C reply was reported as "the
unit was erased".

- get_events() gains only_key_timestamp: with only_key, if the target's 0C
  says another time (or none), the target takes the existing bypass --
  no 1F(arm), no POLL, no 5A.  A new branch only; it adds no command.
- download_event_by_key(key4, *, expected_timestamp=None) passes it on.
- The adapter converts the id's stamp to that ISO form and checks, in
  order: no event -> 404; no readable 0C timestamp -> 502 MalformedReply
  ("could not read ... record (0C)"); a different time -> 409 StaleEvent;
  no frames -> 502.
- The fake's download mirrors the real walk (no frames on a mismatch) and
  records what it was asked for.
- Legacy get_events() (none of the new options) is pinned by a test of
  its exact call sequence and 5A arguments, written before the change.

Read-only; nothing new on the wire.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:38:34 -04:00
serversdownandClaude Opus 5.5 157fcc51a7 fix(sfm): a fresh Series-4 download keeps the unit's own PVS and sensor location
Without Thor's TXT report, save_imported_idf fills only the three PPVs.
The unit's 0x0C record -- already read for the list and the stale check --
also gives the peak vector sum and the sensor location, and they were
dropped: Terra-View showed a blank PVS, and find_twins (which matches on
PVS) could not link the event to its histogram twin.

persist_download now overlays DownloadedEvent.record onto the bridged
event before insert_events, filling only fields the file left empty
(creating PeakValues / ProjectInfo when absent).  Not the mic: its 0x0C
decode reads a denormal, parked.

The sidecar is written by save_imported_idf before the overlay, so it
still has no vector sum; the DB row does.  No schema change, no migration.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:36:15 -04:00
serversdownandClaude Opus 5.5 ef096e3082 fix(sfm): a download never downgrades a stored event -- an existing row is returned, nothing written
THOR's watcher (and Blastware's ACH) store every event through
/db/import/idf_file and /db/import/blastware_file, with the paired report.
Storing a download of the same event afterwards overwrote that richer copy:
on Series 4 the file, .h5 and sidecar were rewritten (extensions dropped);
on Series 3 the row lost PVS, project strings and ZC frequencies and was
repointed at a second, review-less file set.

persist_download now looks up (serial, timestamp) first.  A row there is
returned as it stands -- inserted false, detail.already_stored true -- with
no store call, no insert_events and no sidecar write.  Never merge.

- DownloadedEvent gains `timestamp` (the unit's own event time) and
  `record` (Series 4's 0x0C fields); both adapters set them.
- The Series-3 `event is None` guard now runs before backfill/save, with a
  message that is true there ("nothing was stored").
- Tests build the watcher's state exactly as the import endpoints do and
  prove the row dict, the sidecar bytes and the file mtimes are unchanged.

No schema change, no migration, no codec change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:35:23 -04:00
serversdownandClaude Sonnet 5.5 39e0d312e5 feat(sfm): list and download events by serial for both series
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:07:42 -04:00
serversdownandClaude Opus 5.5 d84204f533 feat(sfm): store a downloaded event -- one ingest for both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:04:44 -04:00
serversdownandClaude Haiku 5.5 9e2d8b62c3 feat(sfm): DeviceAccess lists and downloads events for both series
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:02:19 -04:00
serversdownandClaude Haiku 5.5 0a01a8d2db feat(sfm): Series-4 events -- chain-walk list, download at THOR's cursor
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:59:55 -04:00
serversdownandClaude Opus 5.5 b79309eb72 feat(sfm): Series-3 events -- header list, one-event download, stale ids refused
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:57:26 -04:00
serversdownandClaude Opus 5.5 c85244e0fe feat(sfm): event models and event_id -- serial, key and timestamp
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:54:53 -04:00
serversdownandClaude Opus 5.5 278921796a fix(sfm): any request taking the legacy path is refused beside a held line
The /device guard let every non-UM serial through before its held-line
check.  FastAPI drops an undeclared `serial`, so `?serial=BE18193` on a
legacy route still ran Series-3 code at an address holding a Series-4
line -- the hole the guard exists to close.  Serial-aware routes go
straight to DeviceAccess, which refuses that case itself; everything
else is checked.  baud is no longer parsed (it is not in the address
key, and pydantic's coercion made "38400.0" a second way past).

Also, from the same review:
- RingWatchTransport clears its frame state on every write, so a stray
  STX on an idle line cannot hide the ring that answers the next request.
- Series4Session.is_open reads _client once; held_serial() calls it
  without the unit lock, and a concurrent hang-up between two reads was
  an AttributeError (a 500).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:58:57 -04:00
serversdownandClaude Opus 5.5 d393a149f8 fix(sfm): a different UM serial at a held address is refused (409), not swapped
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:17 -04:00
serversdownandClaude Opus 5.5 aa79e996c5 fix(sfm): construct the DeviceAccess singleton at import
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:17 -04:00
serversdownandClaude Opus 5.5 52ada0215c fix(sfm): RADIO RING detection ignores bytes inside frames
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:10 -04:00
serversdownandClaude Opus 5.5 82b91835fb fix(sfm): one guard in front of every /device route -- UM serials 501 off the serial-aware routes, held lines 409 serial-less requests
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:44:35 -04:00
serversdownandClaude Opus 5.5 e7a5a3cce1 feat(sfm): serial-named /device/info, /status, /settings and /hangup for both series
With serial: one contract for Series 3 and 4 through sfm.device_access.  Without it: the legacy Series-3 path, unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:26:16 -04:00
serversdownandClaude Opus 5.5 73b6089012 fix(sfm): retry once on a dropped held line; refuse Series-3 beside a held Series-4 line
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:23:57 -04:00
serversdownandClaude Opus 5.5 96c7b31f4e feat(sfm): DeviceAccess -- one door, held Series-4 lines, a reaper, and the same answer shape for both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:17:39 -04:00
serversdownandClaude Opus 5.5 ece9ec79e3 feat(sfm): Series-4 identify, status and settings into the shared models
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:15:43 -04:00
serversdownandClaude Opus 5.5 8e7333b899 feat(sfm): Series-4 session -- call up once, stay on the line, release on RADIO RING
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:13:34 -04:00
serversdownandClaude Opus 5.5 d39f8ef360 fix(sfm): Series-3 status says its serial is unverified
Series 3 status reads no serial, so the serial shown is the requested one, not one the unit reported. detail now carries serial_verified=False.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:12:17 -04:00
serversdownandClaude Opus 5.5 5c6ca049c8 feat(sfm): Series-3 adapter -- identify, status, settings into the shared models
Connect-per-request with the TCP cold-boot retry kept; a different unit answering is refused (409) whenever the serial is already in hand.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:10:23 -04:00
serversdownandClaude Haiku 5.5 bb4b26835b feat(sfm): per-unit lock -- one connection per unit, 423 when busy
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:08:10 -04:00
serversdownandClaude Haiku 5.5 034529f498 feat(sfm): device_access core -- typed errors, series by serial prefix, shared models
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:06:20 -04:00
serversdownandClaude Opus 5 6589da445b feat(webapp): cheap connect, opt-in event walk, and a Diagnostics tab
Connecting to a unit fired /device/events automatically, which walks the whole
event chain — every event header over a cellular link. On BE12599 that took
minutes and then 500'd outright, because its buffer has wrapped past 0xFFFF and
the uint16 offset arithmetic goes negative. Wanting to know whether ACH was on
should not require reading every event the unit has stored.

Connect now uses only cheap probes: /device/info (which already carries the
compliance config the event walk was re-reading) plus /device/events/storage_
range. The chain walk moves behind a "Load events" button in the Events
toolbar, and the Device tab gains an Event Chain card showing the first/last
keys.

Adds a Diagnostics tab for the endpoints that previously existed only as curl:
storage_range and events/index alongside monitor/status, then stop monitoring,
disable ACH (rescue?erase=false, so events survive), and erase. The wedged-unit
ladder — slow drip and blind stop — sits under its own heading pointing at the
runbook, with the reminder that slow_drip's success signal is bytes_received>0
and not a clean duration.

Erase is guarded by typing the unit's serial. Auth answers who, not whether you
meant it, and Swagger's try-it-out button on /device/events/erase is live on
:8200/docs — the realistic risk here is an accident.

Lifetime events is displayed but labelled unreliable: SUB 0x08 reports 0 on
units with years of history, which is a decode bug we have not chased yet.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-19 22:05:55 +00:00
serversdownandClaude Opus 4.8 8d3cdba1b5 feat(h5): standardize sensor-check into the .h5 (schema v2); SFM reads it
Make the sensor self-check a first-class part of the standardized decoded event
so SFM stops decoding it at report time — device-agnostic, per the store's
decoder→standardized-.h5→SFM model.

  * Event gains a `sensor_check` field; both decoders attach the traces where
    they set raw_samples — series-3 in event_file_io.read_blastware_file
    (minimateplus.sensor_check), series-4 in waveform_store's IDF path
    (micromate.sensor_check).  Covers ingest and backfill (both re-decode).
  * event_hdf5 bumps schema_version 1→2 and writes an optional /sensor_check
    group (raw counts, int32, per channel present).  read_event_hdf5 returns
    it; plot_json_from_hdf5 carries it as a top-level key.  Old v1 files still
    read cleanly (no group → None), so nothing breaks before the backfill.
  * gather_report_data reads sensor_check_waveforms from the .h5 and drops the
    report-time series-3 decode — the report no longer reaches into a decoder,
    and a series-4 event now lights up the same strip automatically.

Stored as raw counts (a shape diagnostic, rendered fit-to-box): the per-series
count scale differs and a physical mic unit is ill-defined, so conversion would
add complexity for no display benefit — easy to add later if a numeric use
appears.

Tests: .h5 roundtrip + backward-compat + plot_json + real series-3 decode
attaches to the Event.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-16 06:49:55 +00:00
serversdownandClaude Opus 4.8 2a747f6893 fix(report): attach sensor-check strip to the waveform panel; move "0.0"
Match Blastware's layout, measured off the reference PDF: the sensor-check
strip shares a border with the main waveform panel (no gap between them), and
the per-lane "0.0" baseline labels sit to the RIGHT of the strip. Previously
the strip floated with a gap and the "0.0" label overprinted the strip's left
edge. Purely layout — the traces and decode are unchanged.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-15 05:48:31 +00:00
serversdownandClaude Opus 4.8 2c5c20cfd7 fix(report): fit sensor-check mini-plots to their boxes
The sensor-check strip used a symmetric ±max scale, so the one-sided geophone
ring-downs (a dip to ~-990 with the baseline at 0) sat in the bottom half of
each mini-box with the top half blank — visibly off next to Blastware. Scale
each mini-plot to its actual data range with a small pad instead, and draw a
faint zero baseline, so the ring-downs and the mic pulse train fill their boxes
the way BW draws them.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-15 05:39:53 +00:00
serversdownandClaude Opus 4.8 ab9d84fde6 feat(report): render the sensor-check strip + report polish
Wire the decoded sensor self-check waveforms (previous commit) onto the event
report PDF, and fold in two related waveform-panel cleanups.

Sensor-check strip (matches Blastware):
  * ReportData gains sensor_check_waveforms; gather_report_data decodes it from
    the retained raw BW binary (store.paths_for) at report time — no ingest or
    .h5 change, waveform events only.
  * _draw_waveform_subplot now draws a narrow right-hand strip of per-channel
    mini-plots (MicL pulse train + Long/Vert/Tran ring-downs) aligned to the
    lanes, captioned "Sensor Check".
  * stats table gains the "Frequency" / "Overswing Ratio" sub-rows under Sensor
    Check (7.5/7.7/7.3 Hz, 3.6/3.3/3.7), formatted to 1 decimal like BW; values
    come from the already-parsed sensor_check scalars.

Cleanups (pre-existing, in the same panel):
  * fix the stacked-lane y-tick collision — adjacent lanes' -1.0 / 1.0 labels
    overprinted at the shared boundary; prune the extreme ticks (MaxNLocator
    prune="both") so each lane shows clean interior ticks only.
  * fix the header serial+firmware line running off the right page edge —
    tighter right-column indent + BW's slightly smaller 7.5pt header.

Tests: sensor-check + compliance + geo-scale + fft all green (15). The
test_bw_ascii_report failures are pre-existing (gitignored decode-re fixtures
absent in this worktree), unrelated to this change.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-15 05:33:38 +00:00
serversdownandClaude Opus 4.8 dc74c97ade feat(report): size the USBM compliance chart to match Blastware
The compliance chart on the event-report PDF was correctly drawn but far
too small ("it's tiny") — a ~2.6in square dropped between the mic and
stats rows.  Resize + reposition it to match Blastware's Event Report,
measured directly off a BW reference PDF (n844lqhbzt0w) rasterized with
fitz: the chart data box now spans figure fractions x[0.489,0.951]
y[0.502,0.867] — a ~3.9in square running from just under the header down
through the stats band, hard against the right page margin, exactly as BW
draws it.  Title updated to BW's "USBM RI8507 And OSMRE".

To clear room for the BW-sized chart (waveform layout only):
  * _draw_stats_table gains bbox_width/col_widths/fontsize params; the
    waveform layout packs the Tran/Vert/Long table into the left ~0.42 so
    its columns no longer sit under the chart.  Histogram layout keeps the
    wider defaults (byte-identical output; it has no compliance chart).
  * the mic block's long "Channel Test Passed (Freq … Amp … mv)" line gets
    a tighter indent + one-point-smaller font so it ends before the chart's
    left edge instead of running behind it (_kv gains a fontsize param).
  * the Peak Vector Sum line left-aligns under the compacted table (one pt
    smaller) so it clears the chart's bottom-left tick labels.

Chart placement centralized in the _COMPLIANCE_BOX constant. No change to
the compliance math, the scatter, or the histogram report.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-14 22:56:44 +00:00
serversdownandClaude Opus 4.8 95f926c318 feat(report): enlarge the compliance chart to a full upper-right panel
The chart was cramped into the short mic band (~2in) and rendered tiny. Move it
to its own large square panel (_draw_compliance_panel) spanning the mic + stats
rows on the right, clear of the stats columns — matching Blastware's Event
Report proportions. _draw_mic_and_usbm now draws only the mic block.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-14 20:33:09 +00:00