Commit Graph
207 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 342c69602d merge: dev into feat/series4-sfm-parity -- v0.32.0, #42, #47/#49, #44/#45, the S3 decode checker
Brings the branch up to dev (41 commits) before the 1c bench fixes, which
touch code dev changed: the histogram reader (#47/#49, bench finding #2), the
v0.32.0 event-time rules, the Blastware file's setup-block fields (#44/#45),
and the decode checker for verifying stored S3 downloads.

One conflict: the top of the Series-III reference's change table -- both sides
added rows; kept all, in date order, CRLF preserved.  CLAUDE.md, README,
blastware_file.py, models.py and database.py merged cleanly.  Suite: the known
16 failures only (15 test_bw_ascii_report, test_save_imported_bw_without_report_
works_unchanged, which also fails on dev); 1237 passed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 22:51:42 -04:00
serversdownandClaude Opus 5.5 ee02874cb0 feat(sfm): opt-in raw SUB 0x49 code on a Series-4 status read
GET /device/monitor/status?serial=UM...&run_state=true adds
detail.run_state = {code, name}.  For the ring-path bench test: the code
during and after a call-home (0x01 for ~18 s after a stop, inferred to be
call-home attempts; 0x03 = calling home) is what the test watches.  Opt-in
because it is one more round trip (~0.65 s on cellular); a plain status read
is unchanged.  Series 3 has no 0x49 and ignores it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 13:15:44 -04:00
serversdownandClaude Opus 5.5 9082236c5e fix(webapp): the final review's three page findings
- The arrow keys reached the legacy per-index waveform route in serial mode,
  even with no list loaded (an unlocked MiniMate chain walk + 5A on the same
  modem session).  perIndexLive() is now the one rule for the per-index
  buttons, the chips and the keyboard: live only for a list loaded without a
  serial that has events.
- A failed reconnect left the previous unit's confirmation live (badge,
  Diagnostics incl. the unguarded blind/slow-drip stops, call-home read).
  connectUnit() now drops it before it identifies; only this answer confirms.
- Unit strings reached innerHTML: the Device tab's cards (active_setup, new in
  1c) and its compliance/project tables now render as text, and Diagnostics'
  error spans go through escapeHtml().
- CLAUDE.md: the ring-path Runs A/B are a merge gate (the spec's prerequisite
  to a webapp sending serial), not only a use-time one.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 12:16:49 -04:00
serversdownandClaude Opus 5.5 c4cb979dfb feat(webapp): the status panel shows the unit's clock and event count
Task 3's brief asked for them and they were missed: with a serial, the panel
now shows UnitStatus.device_time and event_count, "—" where null (Series 3
reports both as null).  Without a serial the two fields stay hidden.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 12:00:12 -04:00
serversdownandClaude Opus 5.5 a709d2388d feat(webapp): config and call-home writes wait for phases 4-5; Diagnostics only for a confirmed Series-3 unit
- Config, with a serial: Read shows the unit's shared UnitSettings (setup,
  record mode, sample rate, record time, histogram interval, geo trigger,
  notes; — for null) in place of the write form.  settingsRows() is in the
  device-routing block, Node-tested; the rows are rendered as text, since
  setup names and notes come from the unit.
- Write stays off for both series (and without a serial), tooltip
  "Coming in phase 5 (#46)"; Call Home write likewise, "Coming in phase 4".
- Call Home read follows controlsFor().callHomeRead; for a confirmed Series 4
  the tab says "Not yet available for Series 4".
- Diagnostics: every button follows controlsFor().diagnostics (Task 3), and a
  refresh for anything but a confirmed Series-3 unit sends nothing and says
  why.  Its requests carry the typed serial, so the server guard checks it.
- Without a serial the legacy reads are unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:59:11 -04:00
serversdownandClaude Opus 5.5 3f249e2322 feat(webapp): start/stop through the audited serial path, with the honest result
- With a serial, Start / Stop ask first ("Start monitoring on BE9441?"), then
  POST once to the audited change -- never retried; both buttons stay off while
  it is in flight, so a double click cannot send twice.
- The status bar shows changeSummary() of the ChangeResult, on a 409/502 too
  (dry run, already-in-state, confirmed a -> b, or the outcome and read-back);
  an error without one shows its detail verbatim; no reply from SFM says the
  command may have been sent and where to look, rather than that nothing was.
- Then one status read updates the panel.  The legacy 5 s confirm poll is not
  used in serial mode; with a blank serial start/stop are unchanged.
- Diagnostics' Stop, which goes the same way in serial mode, shows the same
  summary; deviceFetch errors carry it for any non-200 ChangeResult.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:56:36 -04:00
serversdownandClaude Opus 5.5 9aae3b09de feat(webapp): list and download events by serial, for both series
- Load events with a serial lists the shared EventRef shape as a table: index,
  time, type, PVS and the three peaks (or —), each row with its own Download.
- Download POSTs the row's event_id; SFM checks and stores it.  The status bar
  says what was stored (or that it already was), and the stored event opens
  in the viewer.  A refusal shows the server's detail verbatim.
- eventView() (device-routing block, Node-tested) reads both event shapes for
  the table, the chips and the peaks bar.
- A list loaded without a serial keeps the chips and the per-index Load /
  Save / Download buttons, unchanged; for a serial-loaded list those buttons
  are off with a tooltip pointing at the rows.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:54:43 -04:00
serversdownandClaude Opus 5.5 44d6e754bd feat(webapp): name a unit by serial; series badge from the unit's own answer; Hang up for Series 4
- A Serial field beside host/port.  With one, the Live tabs use the serial-based
  endpoints (both series); without, every read behaves as before.
- The series badge, Hang up (Series 4), Diagnostics (Series 3), call-home read and
  the disabled config/call-home writes all follow applyControls() <- controlsFor()
  on the unit's own /device/info answer; editing the serial, host or port drops
  the confirmation.  Erase additionally needs a confirmed Series 3.
- Every /device/ request goes through deviceRequest/deviceFetch <- deviceUrl
  (a static test enforces it); the legacy per-event routes joined deviceUrl
  (event_waveform / event_file, index in the path).
- The status panel and Device tab read both shapes (shared and legacy).
- In serial mode the connect skips the legacy storage_range read (one connection
  fewer; a Micromate has no such route).  Start/stop without a serial behave as
  before; with one, only for a confirmed series.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:50:24 -04:00
serversdownandClaude Opus 5.5 e3717706f8 feat(webapp): the device-routing rules as pure functions, tested through Node
One block of sfm_webapp.html (/* <device-routing> */) holds every rule that
decides where a /device/ request goes or whether a series-specific control is
live: seriesFromSerial, unitQuery, deviceUrl, confirmedSeries, controlsFor,
changeSummary, downloadSummary.  No DOM, no fetch, so the tests run it in Node.

The safety rules it pins: a control follows the unit's own /device/info answer,
never a typed serial alone, and stops counting when the serial is edited;
Diagnostics only for a confirmed Series 3, Hang up only for Series 4; config and
call-home writes off for both series until phases 4-5.  Also a test that the
page's inline scripts parse together (shared global scope).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:46:08 -04:00
serversdownandClaude Opus 5.5 1cb11abcef fix(sfm): legacy Series-3 writes and erase refuse a unit that does not answer as Series 3
0xA2 is CONFIRM ERASE on a MiniMate and ends a call-home on a Micromate, and the
legacy host/port routes had no identity check: only the MiniMate parser's
inability to read a Micromate's replies stood between Diagnostics' Erase and a
Micromate (phase 1c safeguard, agreed with Brian 2026-10-28).

_require_series3(unit_serial, expected) refuses (409, 'nothing sent') unless the
unit's own serial is Series 3 and, when ?serial= names one, that one:
- POST /device/config (+ /config/project) and /device/events/erase: the serial
  connect() already reads -- no extra request;
- /device/rescue (when it writes call-home or erases) and POST /device/call_home:
  one SUB 0x15 read (new MiniMateClient.read_serial).
Exempt, with the reason in a comment: legacy monitor start/stop, blind stop, slow
drip, spam -- 0x96/0x97 mean the same on both series (measured), and the rescue
tools must reach a unit too wedged to answer.

Tests: each guarded route refuses a unit answering UM20147 and a different BE
unit with no write call, proceeds for the named unit (normalised), reuses
connect()'s serial where it has one; the blind stop builds no client;
read_serial decodes BE9441's recorded 0x15 reply.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:43:42 -04:00
serversdownandClaude Opus 5.5 6cfcd04513 fix(sfm): an estimated event time never overwrites, merges into or duplicates a row
Brian: keep an event whose time is only an estimate (no validated embedded
event record) -- never discard a measurement for want of an exact timestamp --
but it must not silently cause an overwrite, merge or dedup collision.

insert_events, for timestamp_source 'estimate' (_estimate_guard):
- never restamps (moves) a row;
- if its file (a Blastware name) is already stored under another time, writes
  nothing -- no second row, the stored time kept;
- if a different event already holds that second, writes nothing -- the old
  upsert would have written this event over that one;
- otherwise stores it, or refreshes its own row at the same second, as before.
Each refusal is a WARNING naming both sides; the file and sidecar (which says
'estimate' and carries the decode problem) are already in the store.  A generic
upload name ('imported.bw') is not taken as identity.

Tests: each rule, an estimate on a free second kept, generic names, and an
import end to end (a corrupted record next to a different event's second).
3 mutants, each caught.  Suite vs clean origin/dev: the same 16 failing tests,
failure reasons byte-identical; 582 passed vs 553.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
2026-10-27 00:15:32 -04:00
serversdownandClaude Opus 5.5 ca5c401c6f fix(device_access): a start's read-back waits out the sensor check, then wakes the MiniMate with retries
Second start through SFM, BE9441 2026-10-26 23:54:41: acked 0x69, and Brian saw
'starting, performing sensor check, recording' -- but the read-back's single
SESSION_RESET + POLL went out 2.3 s after the ack, inside the ~30 s sensor
check, and was never answered or re-sent (504 after 120 s, audit ca7b5b42).
Brian: every unit is set to sensor-check before monitoring, ~30 s, then
'Recording...'.

- MiniMateProtocol.wake(attempt_s, deadline_s): SESSION_RESET + POLL re-sent
  every attempt_s until the unit answers, then the POLL data step; a named
  timeout at the deadline.  Reads only.  MiniMateClient.wake() wraps it.
- The Series-3 change: after a START, the first read waits S3_SENSOR_CHECK_S
  (30 s) before asking; every read then wakes with retries (every 5 s, up to
  60 s).  A stop is unchanged -- its read-back was confirmed three times tonight.

Tests: a unit deaf for 4 probes is asked a 5th time and answers; a unit that
never answers ends in the named timeout after ~6 probes; a start's first read
waits the sensor check, a stop's does not; every read is preceded by a wake.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:02:10 -04:00
serversdownandClaude Opus 5.5 f91949be89 fix(decode): a Series-3 waveform's time comes from the instrument's embedded event record
Brian's requirements: the instrument's data is the only time source; a filename
is a cross-check, never a fallback (an event SFM receives itself has none).

The record (found by reading a seismo_lab Inspector dump; Series-III reference
§7.8.9): 00 28 05 00 ?? ?? | fe 80 | trigger | stop, times dd mm yyyy(BE) 00 hh
mm ss.  Measured on 7,935 waveforms (DL2 + prod store): exactly one candidate
validates in every file; trigger = Blastware's report 1,320/1,320, = filename
7,935/7,935, = the unit's 0C record 10/10.

Provenance (requirement 6, measured): in Blastware's download of 8 BE9441
events the record -- with 24 B before and 22 after -- occurs exactly once in the
unit's own A5 reply payloads; SFM-only downloads (no Blastware) carry it too.
It is instrument data, not Blastware's.

- _embedded_event_record(): every fe 80 before the footer is a candidate; it
  counts only with the lead bytes, two well-formed times (zero byte zero),
  footer ts1 <= trigger <= stop, stop = footer ts2 or a second before, and a
  length matching the record time.  Exactly one must count; none or several is
  a decode problem, never a guess.
- Without one: the footer estimate, timestamp_source 'estimate', a
  decode_problems entry, a WARNING.  No filename fallback.
- A filename that disagrees is logged; the decoded time is kept.  A paired
  report fills in only without a validated record (apply_report_to_event, the
  sidecar dict overlay, event_to_sidecar_dict) and is logged when it disagrees.
- decode_blastware_bytes(raw, name=None): no file or name needed;
  save_imported_bw uses it (no temp file).  Event gains timestamp_source and
  decode_problems; the sidecar records both.
- Histograms unchanged (#51): their record (fe f5) is noted, not used.

Tests: raw bytes with no name (ZI0, 7 BE12844 oracles), a disagreeing name, each
validation rule alone, two valid candidates, no filename fallback, report
precedence, sidecar.  7 mutants, each caught.  Real data, decoded with no name:
7,961/7,961 waveforms on the record, 0 disagreements with filename or report;
10,433/10,433 prod histograms unchanged.  Suite: only the 16 known failures.

Open (reported, not changed): 3 DL2 files named as waveforms whose body the
waveform codec does not recognise keep the footer start, 4 s off, as on dev.
None in prod.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
2026-10-26 23:59:22 -04:00
serversdownandClaude Opus 5.5 9886422212 fix(device_access): wake a MiniMate before every state read in a start/stop, so a start's read-back is answered
BE9441, 2026-10-26 23:41:48 (through the bridge): SFM's start (0x96, Blastware's
own bytes) was acked 0x69 and the unit began monitoring -- Brian saw it -- but
the read-back sent one bare 0x1C two seconds later and got nothing for 120 s,
so the change reported 'sent and acknowledged, but reading the state back
failed' (504, audit 0c1cf813).  Nothing was retried.

A monitoring MiniMate ignores a bare request until SESSION_RESET + POLL
(measured 2026-04-08).  The read-back had relied on the connect's wake; a stop's
read-back (18:53, the unit idle by then) never needed it.  Every state read in
the change now goes through _woken_state: client.poll() (41 03, POLL, 41 03,
POLL -- the connect's own sequence), then 0x1C.

Test: after the send, every 0x1C read is preceded by a POLL.  No codec, store or
DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 23:51:15 -04:00
serversdownandClaude Opus 5.5 3948dc1a3c fix(decode): a Series-3 waveform's time comes from its Blastware filename
The review of this branch measured (and I re-measured) that the binary's
trigger -- ts2 minus the record time, from 1e76d08 -- is a second off on 260 of
prod's 1,394 waveforms (2026-09-30 snapshot): 199 late, 61 early.  A Blastware
filename encodes Blastware's own time to the second: it equals the report's
Event Time on 81/81 prod and 1,249/1,249 DL2 report-paired waveforms.

The cost of the second was real, not cosmetic:
- events is unique on (serial, timestamp), and on BE9558 the 61 early
  waveforms land on their histogram twin's second -- a fresh import wrote each
  waveform over its histogram's row (888 files -> 827 rows on dev);
- the release backfill would have moved 161 prod rows that v0.31.0 already had
  exactly right a second off.

Same-second collisions across all 11,827 prod-snapshot files: 61 with the
binary's times, 0 with waveform names.  Histograms keep the binary's ts1: their
name is Blastware's start time too (13,089/13,089) and ts1 runs a second early
on 97% of them, but with both on Blastware's times a waveform and its
histogram share a second 209 times -- the key cannot hold that.  Correcting
histogram times needs the key changed; not here.

- blastware_file.blastware_filename_time(): the inverse of
  blastware_filename(), V10.72 'AB0' names only, None for anything else.
- read_blastware_file(path, *, name=None): a waveform takes the name's time;
  save_imported_bw passes the upload's real name (it reads a temp file).
- insert_events' restamp matches only Blastware names (every unnamed upload is
  'imported.bw', so two events could share it) and, of several copies, moves a
  reviewed one with a time first (review items M1, M2).

Tests: the decoder (documented names, encoder round trip, other names), a
waveform's name time, a temp-named read, histograms unchanged, the twin
collision on BE9441's own ZI0 (binary 14:23:43, Blastware 14:23:42), and both
review items.  5 mutants, each caught.  Suite: only the 16 known failures.

Codec-library change: TOOL_VERSION to be bumped at release.  No schema change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
2026-10-26 19:15:59 -04:00
serversdownandClaude Opus 5.5 d990466407 fix(minimateplus): the 0x1C status reads a histogram run as monitoring, and unescapes before counting from the end
Measured on BE9441 tonight, through the recording bridge:

- Monitoring flag 0x0B while recording a histogram (confirmed at the unit), 0x00
  idle.  Only 0x10 had been measured as monitoring (BE11529, 2026-04-08), so the
  status showed 'not monitoring' and the change path refused the state as
  unknown(0x0B) -- refused, not skipped, which is the design working.  0x0B joins
  S3_RUN_STATES and S3_MONITORING_FLAGS as measured.  The shared status's
  'monitoring' now follows the change path's reading: None for an unmeasured
  flag, never a guessed False.
- Free memory 0x000D0E04 arrived as 0d 0e 10 04.  The parser keeps the 10 of a
  10 02/03/04 escape, so every field counted from the end read one byte off:
  419.84 V and 251,655,168 bytes for 6.76 V and 983,028.  New
  framing.unescape_reply() (also used by parse_strt_end_key) runs first.

Tests: the two recorded replies (idle 16:24, monitoring 18:47) decode to the
unit's own values; each escaped value in the last ten bytes decodes; the status
mapping for 00 / 10 / 0B / unmeasured.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 18:53:11 -04:00
serversdownandClaude Opus 5.5 847900baeb fix(sfm): a re-stored event at a corrected time moves its row instead of duplicating it
The waveform event-time fix (a84a46e / 1e76d08, on dev since 2026-09-20)
changed what time a Series-3 waveform decodes to: the trigger, where v0.31.0
stamped the monitoring-session start -- hours off.  events is unique on
(serial, timestamp), so re-storing an old event at its corrected time matched
nothing and inserted it a second time.

Measured 2026-10-26: files stored with v0.31.0 (prod's code), then dev's
backfill_sidecars --force -- the release's own deploy step -- gave every
waveform two rows, one at each time.  N844LQHB.ZT0W (BE12844): 06:00:13 and
10:33:29, its false-trigger mark only on the wrong-time copy.  A Blastware
re-forward of an old event would do the same with no backfill at all.  Prod
has not run the new decoder, so it holds no duplicates yet.

insert_events now matches a row by its stored file first (serial +
blastware_filename; a Blastware name encodes the serial and the second): one
under another time is moved to the new time in place -- same id, review kept --
and the usual refresh follows.  When a different stored file already holds the
corrected second, nothing moves and nothing is written; the old upsert wrote
this event's file and peaks over that other event's row.  Rows with no stored
file are matched on time alone, as before.

Tests: the move (id, review, refresh), a different file, no file, the
collision, a duplicate already at the new time, and the release backfill end
to end on a v0.31.0-shaped row.  Re-checked across versions: v0.31.0 import,
then this branch's backfill -- 5 real files, every row corrected in place, no
duplicates.  Suite: only the 16 known fixture failures.

No schema change, no migration, no codec change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
2026-10-26 18:18:23 -04:00
serversdownandClaude Opus 5.5 6f31eca366 docs: the 64 KB page bug is fixed; the 5A 'non-standard frame' model retracted in place
CLAUDE.md: the KNOWN BUG entry marked fixed (887e75d) with what settled it, and
retraction notes under the 5A sections that described the misreading (partial
stuffing, offset_hi 0x10 raw, 11-byte params, metadata pages 0x1002/0x1004).
Series-III reference: a 2026-10-26 (3) row.  Spec: the MiniMate check updated.
Code comments that called the page bug open, updated; the adapter's struct.error
mapping kept as a defence, its message and test no longer naming the old bug.

Verified live on BE9441 the same day: all 8 events downloaded by serial, the 4
that cross a 64 KB page included, each whole and matching the unit's own peaks.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 14:44:11 -04:00
serversdownandClaude Opus 5.5 c32a9e7851 fix(sfm): a MiniMate download that decodes as nothing is refused, not stored as a histogram
Review of 36f4e5d (measured): with the metadata-page bug put back, 4 of 7
BE12599 non-first waveforms decoded to nothing, and the check stored them
unverified as 'a histogram' -- the worst form of the bug it was built for.
Now: no waveform decode must decode as a histogram (stored unverified) or it is
refused; a waveform's record chain must end on its END record (0x06), as the
file reader requires -- cut-short streams have none; the structure checks run
for every unit and only the peak comparison is limited to a unit confirmed in
normal range (geo_range == 0; an unread range is no longer assumed normal);
a clipped blast at full scale on both sides counts as a match.  Tests pin the
one-step tolerance, both ranges, the END record and the neither case.

No DB or schema change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:47:39 -04:00
serversdownandClaude Opus 5.5 36f4e5d985 feat(sfm): a MiniMate download is checked against the unit's own peaks before it is stored
Series 4 downloads were checked (decoded PVS against the unit's); Series 3's
were stored unchecked (verified=None), so BE9441's two bad files went in as
successes at the bench (2026-10-25).  verify_s3_download(): if the waveform
decodes, all three geophone channels must be the same length and each peak must
be the unit's own 0C peak to one 0.005 in/s step, or the download is refused
(MalformedReply, "not saved").  Unverified (stored, as before): no waveform
decode -- a histogram; 0 of ~430 fixture histograms decode as one -- or a
sensitive-range unit, whose scale is still open.  The reason goes in
detail["check"].

A test puts the metadata-page bug back and the check refuses the file it
produced.  Session-replay helpers move to tests/minimate_replay.py.

No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:14:44 -04:00
serversdownandClaude Opus 5.5 cdc6360ec0 fix(sfm): an audit finish that fails on a hang-up path still releases the line
The final fix wave's AuditIncomplete landed in _exchange's `except DeviceError`,
which keeps the line -- so on the nine ring / link-fault paths (and a refusal) a
failed audit write turned a hang-up into a held Series-4 line, blocking a THOR
call-home for up to the 5-minute idle hang-up and making "SFM hung up" false.
AuditIncomplete now carries release_line, set by every finish whose path hangs
up anyway, and _exchange honours it.  Also pins the Series-3 change path's
retry=False again (the rewritten lost-ack test no longer could).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:36:00 -04:00
serversdownandClaude Opus 5.5 8f68b09f5e fix(sfm): a change that fails after the send says so; the audit row records sent + states; S3 unknown states refused
Final fix wave for phase 3 (start/stop monitoring), per the whole-phase review.

- I1 + M2: every failure after the send has started is a ChangeUnconfirmed
  (audit_id, sent = "acknowledged" | "unknown", the cause's HTTP status) whose
  message says the frame was sent and names the audit record -- the ring in
  place of the ack, the four lost-ack follow-ups, and the three read-back
  paths.  Series4Session releases the line on it.  Every audit finish goes
  through one helper; a finish that fails is AuditIncomplete (500) and still
  says what happened to the unit.  The line is kept.
- I2: device_commands gains `sent` (1 acknowledged, 0 nothing sent, NULL
  unknown) and `states` (before / seen / after), with an idempotent ADD COLUMN
  in _migrate for a table created earlier on this branch.
- M1: a RADIO RING already buffered is caught before 0x96/0x97 goes out
  (pre_send = read_unsolicited, one 10 ms transport read).  That is a
  CallHomeInProgress with sent=0, not ChangeUnconfirmed.
- M3: Series 3 reads the raw 0x1C flag (new MonitorStatus.state_flag); a byte
  other than 0x00/0x10, or a short section, is unknown(...) and refused.
- M8: even_if_already on a unit already in the state notes that the read-back
  proves nothing.
- M10: a scan pins `.protocol.execute(` to sfm/device_access/s4.py; both
  scans fail closed on a file that does not parse.
- M11: docs corrected (CLAUDE.md phase-2 sentence, phase-3 bullet, REST list;
  micromate/protocol.py scope and the 0x49 read_state docstring; s4.py; route
  docstrings).  "No command has ever been originated" is NOT retracted.
- M12: GET /db/device_commands normalises the serial.
- Minors: unused imports, S3 dry-run frames and 120 s timeout pinned, test
  rename, serial-cache and short-0x49 tests, _RUN_STATES comment.

Schema: two NULLable columns on the branch-new device_commands table, added
by _migrate on open; no backfill.  No codec change, TOOL_VERSION unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:16:45 -04:00
serversdownandClaude Opus 5.5 ac33c8ffa4 fix(sfm): start/stop HTTP status is an allow-list -- only verified, skipped or dry-run is 200
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 17:00:31 -04:00
serversdownandClaude Opus 5.5 c3e7e169c0 feat(sfm): start/stop monitoring by serial -- dry run, audit, read-back
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:57:47 -04:00
serversdownandClaude Opus 5.5 ce5d2cb0d6 feat(sfm): start/stop monitoring for Series 3 through the same safety layer
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:48:05 -04:00
serversdownandClaude Opus 5.5 78c3d568d5 test(sfm): pin the ring-on-follow-up and calling-home poll exits; narrow the refusal clause
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:45:02 -04:00
serversdownandClaude Opus 5.5 14ea80f5a4 fix(sfm): a ring or a refusal is never mistaken for a send; fresh serial pinned; unmeasured states refused
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:39:55 -04:00
serversdownandClaude Opus 5.5 eada7ba767 feat(sfm): start/stop monitoring for Series 4 -- identity, state, dry run, audit, read-back, never retried
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:29:03 -04:00
serversdownandClaude Opus 5.5 ff0cce1cb2 fix(sfm): an audit row can be finished once, from pending -- anything else raises
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:24:46 -04:00
serversdownandClaude Opus 5.5 fb9b48f259 feat(sfm): device_commands audit table -- one row per change attempt
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:22:28 -04:00
serversdownandClaude Opus 5.5 e506bcff9b fix(sfm): Thor .h5 samples use Thor's LSB, not the MiniMate count scale (#42)
Every idf-import .h5 converted Thor's raw geo counts with the MiniMate
body-codec scale, full_scale / _GEO_INT16_FS.  A Thor count is
0.000310308 in/s (micromate.idf_file._GEO_LSB_IPS), so the float samples
disagreed with the event's own peak by a constant:

  10/32768 (until 686ab6e, 2026-08-25)   samples -1.65%
  10/32000 (since)                       samples +0.71%

v0.30.0's LSB fix (726c2ce) never reached this path.  It corrected the
decoder's peaks, which were already right in the DB, sidecar and h5
peak attrs.  The sample arrays go through the shared .h5 writer instead.

write_event_hdf5 now takes geo_ips_per_count.  save_imported_idf and
backfill_thor_events (which replays the same bridge with its own write)
both pass _GEO_LSB_IPS.  MiniMate callers are unchanged.

Measured: all 8 thor-idf fixtures (4 IDFW + 4 IDFH, 24 channels) go from
max|sample| / peak = 1.00706 to 1.00000 through the real ingest path.

Operational consequence: no schema change, no migration, TOOL_VERSION
not bumped here.  Existing idf-import .h5 files keep the wrong scale
until regenerated: scripts/backfill_thor_events.py (--force, or bump
TOOL_VERSION at release), then backfill_event_shape.py, because the
offset detector reads these samples.  Series-3 files are unaffected.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-23 13:05:51 -04:00
serversdownandClaude Opus 5.5 a130107fdf fix(sfm): a Series-4 record whose timestamp did not decode is not called stale
Mirrors the Series-3 fix (F3): an unreadable 0C timestamp is a decode or
comms fault, not proof the unit was erased.  Nothing is downloaded.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:58:18 -04:00
serversdownandClaude Opus 5.5 2a70faf7b5 docs(sfm): state the held-line invariant, pin the hang-up on a library error, correct the README
- Series4Session's docstring now states which errors keep the line: an
  op raises a DeviceError only for a verdict on a healthy link (not
  found, stale, unnameable), and _exchange keeps the line for those; any
  library error means the link is suspect and hangs up.  DecodeMismatch
  is a library error and hangs up -- conservative.  Later ops must keep
  to it.
- Test: a micromate TimeoutError mid-download, on a fresh DeviceAccess
  (no retry path), is NoAnswer, closes the client once and leaves no held
  line.  It pins existing behaviour; a mutation that keeps the line on
  library errors makes it fail.
- README, event rows corrected in place: another unit's id is 422 (not
  409); a stale id is 409 without downloading, both series; an event
  already stored -- including by THOR's watcher -- returns its row and
  changes nothing (detail.already_stored); MiniMate lists give
  record_type null, on the normal timeout, and fail on a lost reply.

No code behaviour change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:41:26 -04:00
serversdownandClaude Opus 5.5 4e1e6a9d5c fix(sfm): Series-3 events list with no record type, not a wrong one
minimateplus's _extract_record_type returns "Waveform" for every 0C
record layout -- it cannot tell a histogram -- so a MiniMate histogram
was listed as "waveform".  The fake's "Histogram" was a value the real
client never produces, which is why no test saw it.

- _s3_ref: record_type is always None, with
  detail.record_type_note = "Series 3's event record does not say
  waveform or histogram; not decoded yet".
- default_s3_events(): both events "Waveform", as the real client gives.
- The shared-shape contract test allows exactly {"record_type"} to be
  None for Series 3 and nothing for Series 4.

Rows SFM stores for Series 3 still carry "Waveform" from the decode (the
same as the legacy blastware_file route); parked in the spec.  No codec,
store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:40:26 -04:00
serversdownandClaude Opus 5.5 59dff06f1c fix(sfm): the Series-3 header walk fails loudly, and listing uses the normal timeout
One lost 1F reply made the list return 1 of 3 events as a 200, and on a
download gave a false 404.  The list also ran on the 120 s download
timeout, so each lost reply stalled the walk 120 s with the unit locked.

- get_events() strict mode (headers_only, or only_key): a lost 0A reply,
  a lost 1F(browse) reply on the success path and on the partial-record
  path all re-raise their ProtocolError; a 1F that hands back a key
  already walked raises ProtocolError("event chain did not advance ...").
  Legacy calls (none of the new options) behave exactly as before --
  pinned by tests of the same three faults under get_events().
- Series3Adapter.list_events runs on the default timeout (10 s on TCP);
  download_event keeps 120 s.
- FakeProto gains optional lost-reply injection; its default is unchanged.

The repeat-key guard sits at the loop head, which is reached only for a
non-null key -- equivalent to checking each 1F's key, in one place.

Read-only; nothing new on the wire.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:39:54 -04:00
serversdownandClaude Opus 5.5 01b9188f25 fix(sfm): a stale Series-3 id is refused before the full download, not after
Series3Adapter.download_event compared the timestamp only after
download_event_by_key had run the whole 5A.  A stale id cost a full
download of the wrong event (minutes on cellular), could surface the
64 KB-page 502 instead of 409, and a lost 0C reply was reported as "the
unit was erased".

- get_events() gains only_key_timestamp: with only_key, if the target's 0C
  says another time (or none), the target takes the existing bypass --
  no 1F(arm), no POLL, no 5A.  A new branch only; it adds no command.
- download_event_by_key(key4, *, expected_timestamp=None) passes it on.
- The adapter converts the id's stamp to that ISO form and checks, in
  order: no event -> 404; no readable 0C timestamp -> 502 MalformedReply
  ("could not read ... record (0C)"); a different time -> 409 StaleEvent;
  no frames -> 502.
- The fake's download mirrors the real walk (no frames on a mismatch) and
  records what it was asked for.
- Legacy get_events() (none of the new options) is pinned by a test of
  its exact call sequence and 5A arguments, written before the change.

Read-only; nothing new on the wire.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:38:34 -04:00
serversdownandClaude Opus 5.5 157fcc51a7 fix(sfm): a fresh Series-4 download keeps the unit's own PVS and sensor location
Without Thor's TXT report, save_imported_idf fills only the three PPVs.
The unit's 0x0C record -- already read for the list and the stale check --
also gives the peak vector sum and the sensor location, and they were
dropped: Terra-View showed a blank PVS, and find_twins (which matches on
PVS) could not link the event to its histogram twin.

persist_download now overlays DownloadedEvent.record onto the bridged
event before insert_events, filling only fields the file left empty
(creating PeakValues / ProjectInfo when absent).  Not the mic: its 0x0C
decode reads a denormal, parked.

The sidecar is written by save_imported_idf before the overlay, so it
still has no vector sum; the DB row does.  No schema change, no migration.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:36:15 -04:00
serversdownandClaude Opus 5.5 ef096e3082 fix(sfm): a download never downgrades a stored event -- an existing row is returned, nothing written
THOR's watcher (and Blastware's ACH) store every event through
/db/import/idf_file and /db/import/blastware_file, with the paired report.
Storing a download of the same event afterwards overwrote that richer copy:
on Series 4 the file, .h5 and sidecar were rewritten (extensions dropped);
on Series 3 the row lost PVS, project strings and ZC frequencies and was
repointed at a second, review-less file set.

persist_download now looks up (serial, timestamp) first.  A row there is
returned as it stands -- inserted false, detail.already_stored true -- with
no store call, no insert_events and no sidecar write.  Never merge.

- DownloadedEvent gains `timestamp` (the unit's own event time) and
  `record` (Series 4's 0x0C fields); both adapters set them.
- The Series-3 `event is None` guard now runs before backfill/save, with a
  message that is true there ("nothing was stored").
- Tests build the watcher's state exactly as the import endpoints do and
  prove the row dict, the sidecar bytes and the file mtimes are unchanged.

No schema change, no migration, no codec change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:35:23 -04:00
serversdownandClaude Sonnet 5.5 39e0d312e5 feat(sfm): list and download events by serial for both series
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:07:42 -04:00
serversdownandClaude Opus 5.5 d84204f533 feat(sfm): store a downloaded event -- one ingest for both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:04:44 -04:00
serversdownandClaude Haiku 5.5 9e2d8b62c3 feat(sfm): DeviceAccess lists and downloads events for both series
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:02:19 -04:00
serversdownandClaude Haiku 5.5 0a01a8d2db feat(sfm): Series-4 events -- chain-walk list, download at THOR's cursor
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:59:55 -04:00
serversdownandClaude Opus 5.5 b79309eb72 feat(sfm): Series-3 events -- header list, one-event download, stale ids refused
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:57:26 -04:00
serversdownandClaude Opus 5.5 c85244e0fe feat(sfm): event models and event_id -- serial, key and timestamp
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:54:53 -04:00
serversdownandClaude Opus 5.5 278921796a fix(sfm): any request taking the legacy path is refused beside a held line
The /device guard let every non-UM serial through before its held-line
check.  FastAPI drops an undeclared `serial`, so `?serial=BE18193` on a
legacy route still ran Series-3 code at an address holding a Series-4
line -- the hole the guard exists to close.  Serial-aware routes go
straight to DeviceAccess, which refuses that case itself; everything
else is checked.  baud is no longer parsed (it is not in the address
key, and pydantic's coercion made "38400.0" a second way past).

Also, from the same review:
- RingWatchTransport clears its frame state on every write, so a stray
  STX on an idle line cannot hide the ring that answers the next request.
- Series4Session.is_open reads _client once; held_serial() calls it
  without the unit lock, and a concurrent hang-up between two reads was
  an AttributeError (a 500).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:58:57 -04:00
serversdownandClaude Opus 5.5 d393a149f8 fix(sfm): a different UM serial at a held address is refused (409), not swapped
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:17 -04:00
serversdownandClaude Opus 5.5 aa79e996c5 fix(sfm): construct the DeviceAccess singleton at import
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:17 -04:00
serversdownandClaude Opus 5.5 52ada0215c fix(sfm): RADIO RING detection ignores bytes inside frames
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:10 -04:00
serversdownandClaude Opus 5.5 82b91835fb fix(sfm): one guard in front of every /device route -- UM serials 501 off the serial-aware routes, held lines 409 serial-less requests
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:44:35 -04:00
serversdownandClaude Opus 5.5 e7a5a3cce1 feat(sfm): serial-named /device/info, /status, /settings and /hangup for both series
With serial: one contract for Series 3 and 4 through sfm.device_access.  Without it: the legacy Series-3 path, unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:26:16 -04:00